Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAdmitted-Finance AT DATMA MORE PO KUJU PS MANDU DISTRICT RAMGARH JHARKHAND | KUJU | RAMGARH | JHARKHAND | L1 | Admitted-Finance | |
| 2 | L2₹4.3 L+₹2,434 (0.57%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹4.4 L+₹9,164 (2.15%)Admitted-Finance NEAR ALANKAR HALL DATMA MORE KUJU DISTRICT RAMGARH JHARKHAND | KUJU | RAMGARH | JHARKHAND | L3 | Admitted-Finance | |
| 4 | Not Admitted-Fee/PreQual/Technical BHARECH NAGAR SANDI NEAR MIDAS TYRE RAMGARH 829117 JHARKHAND INDIA | RAMGARH | RAMGARH | JHARKHAND | 829117 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | SINHA SALES & SERVICES L2 | M/S A-ONE MOTOR GARRAGE L3 | M/S SALAAM ENGINEERING L1 |
|---|---|---|---|---|---|---|
| 1.00 | Harness of swing generator to DC panel (Q50mm2) – 14 meter X 2 nos. Harness of Propel motor to LVCR (Q50mm2) – 15 meter X 2 nos | 58 | Mtr | 681 ₹39,498 Lowest | 700 ₹40,600 | 681 ₹39,498 Lowest |
| 2.00 | Harness of swing generator to DC panel (Q6mm2) – 14 meter X 11 nos. Harness of field of propel motor to LVCR (Q6mm2) – 15 meter X 02 nos. | 184 | Mtr | 80 ₹14,720 | 80 ₹14,720 | 79 ₹14,536 Lowest |
| 3.00 | Harness of steering motor and steering system (Q6mm2) – 15 meter X 05 nos. Harness for supplementary wire(Q6mm2) – 15 meter X 01 nos | 90 | Mtr | 80 ₹7,200 | 80 ₹7,200 | 79 ₹7,110 Lowest |
| 4.00 | Cutting electrode for gauging of cracked portion of DC panel structure and bulged portion. (Lotherm – L-802 or equivalant) | 10 | KG | 500 ₹5,000 Lowest | 500 ₹5,000 Lowest | 500 ₹5,000 Lowest |
| 5.00 | Suitable steel electrode for material filling and welding of support plate of DC panel structure (Electrode- Lomelt-210 or equivalant) | 28 | KG | 3,240 ₹90,720 Lowest | 3,255 ₹91,140 | 3,250 ₹91,000 |
| 6.00 | Harness of resistance panel RB1 and RB2 to DC Panel (a)Crowd motor ckt. (Q6mm2) – 5mtr X 5nos. | 25 | Mtr | 82 ₹2,050 | 85 ₹2,125 | 75 ₹1,875 Lowest |
| 7.00 | (b) Hoist motor ckt. (Q6mm2) – 5mtr X 5nos. | 25 | Mtr | 82 ₹2,050 | 85 ₹2,125 | 75 ₹1,875 Lowest |
| 8.00 | (c) Swing motor ckt. (Q6mm2) – 5mtr X 6nos. | 30 | Mtr | 82 ₹2,460 | 85 ₹2,550 | 75 ₹2,250 Lowest |
| 9.00 | (d) Propel motor ckt. (Q6mm2) – 5mtr X 2nos. | 10 | Mtr | 82 ₹820 | 85 ₹850 | 75 ₹750 Lowest |
| 10.00 | (e) Trip motor ckt. (Q6mm2) – 5mtr X 3nos. | 15 | Mtr | 82 ₹1,230 | 85 ₹1,275 | 75 ₹1,125 Lowest |
Tender Value
₹5.2 L
EMD Value
₹6,500
Closing Date
31 Jul 2026, 6:00 pmClosed
Project engineer(X)
Office of Project Engineer (Excavation), Tapin North OCP, Hazaribagh Area
Repairing of wiring circuit of Swing generator and resistance panel and wiring harness of LVCR assembly to propel mo-tor and steering system work along with repairing of isolator and VCB assembly of EKG Shovel sl. No- 554
2026_CCL_362251_1
PE(X)/Tapin(N)OCP/NIT/26-27/22 dt. 20.07.2026
Open Tender
Excavation Department Work
Item Wise
11 days
Tapin North OCP
Please refer Tender documents.
2 documents required · 2 mandatory
₹6,500
1 Sept 2026
20 Jul 2026
1 Aug 2026
21 Jul 2026
31 Jul 2026
21 Jul 2026
21 Jul 2026 - 25 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Harness of swing generator to DC panel (Q50mm2) – 14 meter X 2 nos. Harness of Propel motor to LVCR (Q50mm2) – 15 meter X 2 nos | 58 | Mtr | - | - |
| 2 | Harness of swing generator to DC panel (Q6mm2) – 14 meter X 11 nos. Harness of field of propel motor to LVCR (Q6mm2) – 15 meter X 02 nos. | 184 | Mtr | - | - |
| 3 | Harness of steering motor and steering system (Q6mm2) – 15 meter X 05 nos. Harness for supplementary wire(Q6mm2) – 15 meter X 01 nos | 90 | Mtr | - | - |
| 4 | Cutting electrode for gauging of cracked portion of DC panel structure and bulged portion. (Lotherm – L-802 or equivalant) | 10 | KG | - | - |
| 5 | Suitable steel electrode for material filling and welding of support plate of DC panel structure (Electrode- Lomelt-210 or equivalant) | 28 | KG | - | - |
| 6 | Harness of resistance panel RB1 and RB2 to DC Panel (a)Crowd motor ckt. (Q6mm2) – 5mtr X 5nos. | 25 | Mtr | - | - |
| 7 | (b) Hoist motor ckt. (Q6mm2) – 5mtr X 5nos. | 25 | Mtr | - | - |
| 8 | (c) Swing motor ckt. (Q6mm2) – 5mtr X 6nos. | 30 | Mtr | - | - |
| 9 | (d) Propel motor ckt. (Q6mm2) – 5mtr X 2nos. | 10 | Mtr | - | - |
| 10 | (e) Trip motor ckt. (Q6mm2) – 5mtr X 3nos. | 15 | Mtr | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
cancelled_1.pdf
pdf • 0.37 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 3.00 MB
BOQ_375150.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .