| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC | ₹14.7 L | L1 | Accepted-AOC ACCEPTED |
| 2 | L2₹19.0 LRejected-Finance 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | ₹19.0 L | L2 | Rejected-Finance L2 |
| 3 | L3₹19.8 LRejected-Finance | ₹19.8 L | L3 | Rejected-Finance L3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not recommended not enlisted in cat c(vi), Doc to prove eligibility not uploaded on Def Proc Portal. |
| 5 | Rejected-Technical 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | - | - | Rejected-Technical Not recommended not enlisted in cat c(vi), Doc to prove eligibility not uploaded on Def Proc Portal. |
| Sl No | Description | Qty | Unit | rajengineers L1 | fakhrie apostrical L2 | M/s Dhruve Construction L3 |
|---|---|---|---|---|---|---|
| 1.00 | Material & Labour in repair for sub main wiring with 2 run single core multistranded copper conductor cable of size 2.5 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke ), drawn through and including mild steel ERW conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 2.5 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete all as specified as directed by Engineer in Charge.
Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment. | 240 | Running Meter | 221 ₹53,040 | 140 ₹33,600 | 290 ₹69,600 |
| 2.00 | Material & labour in repair for Point wiring with 2.5 sqmm(22/.3mm) PVC insulated and unsheathed FRLS single core multistranded copper conductor for one light/fan/bell point in and including PVC rigid non metallic concealed conduit 19/20 mm dia, medium duty, ISI Marked to be terminated in modular metal box , modular fittings etc including 2.5 sqmm (22/.3 mm ) PVC insulated and unsheathed FRLS single core multistranded copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment complete all as specified as directed by Engineer in Charge. | 10 | POINT | 1,170 ₹11,700 | 500 ₹5,000 | 1,415 ₹14,150 |
| 3.00 | Supply and fixing in repair modular Socket 6A/16A - 2/3 pin combined 2 module complete all as specified as directed by Engineer in Charge. | 10 | EACH | 450 ₹4,500 | 150 ₹1,500 | 510 ₹5,100 |
| 4.00 | Supply and fixing in repair Modular switch 1 way 16A, 1 module complete all as specified as directed by Engineer in Charge. | 10 | EACH | 150 ₹1,500 | 100 ₹1,000 | 90 ₹900 |
| 5.00 | Supply and fix in repair MCB’s single pole, 6 to 32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete all as specified as directed by Engineer in Charge. | 40 | EACH | 125 ₹5,000 | 200 ₹8,000 | 90 ₹3,600 |
| 6.00 | Supply and fix in repair MCB’s single pole & neutral, 6-32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete all as specified as directed by Engineer in Charge. | 20 | EACH | 550 ₹11,000 | 500 ₹10,000 | 640 ₹12,800 |
| 7.00 | M&L for Checking, inspecting and finding of faults in looping, siren, wiring, panel working of existing fire alarm system from OEM engineers and rectification of defects. Control electrical wiring connected to fire alarm sytem including programming of panel/module smoke detector etc complete all as specified as directed by Engineer in Charge. | 4 | EACH JOB | 15,000 ₹60,000 | 1,500 ₹6,000 | 19,950 ₹79,800 |
| 8.00 | M&L for checking/testing of fire alarms system complete incuding checking of all connection, between each module upto panel all as specified and as directed by Engr -in- charge.
Note (i) Cost of replacement of any module i.e smoke detector, MCB, Siren to be paid under relevant items. (ii) Testing should be done in 03 Places/points of each location or as directed by Engr-in-charge) | 40 | EACH JOB | 2,550 ₹1.0 L | 1,200 ₹48,000 | 2,600 ₹1.0 L |
| 9.00 | M&L for servicing ,cleaning of smoke detector of any type (Addressable/non conventional), and refixing the same complete all as specified as directed by Engineer in Charge.
Note Cost of necessary T&P like ladder required at site are deemed to be included in the quoted rate | 325 | EACH JOB | 50 ₹16,250 | 200 ₹65,000 | 260 ₹84,500 |
| 10.00 | Supply, installation, commissioning and testing of Analogue Addressable Fire Alarm Control Panel including detector wise configuration facility 200 Event storage with Real Time Clock, upto 192 grouping facility, Pre Alarm Action, Programmable Detector sensivity. Device type verification, Earth fault annunciation facility at 0 ohms, Double Address Sensing, Loop wise device test, 40 x 4 characters LCD display 4 numbers of loop card and 254 devices in any combination per loop. Day / Night mode facility. USB 2.0 interface for PC connectivity. Rs. 485 Communication facility for Network / Repeater / MODBUS / BACnet. Programmable Auto Silence Facility. Programmable AC Loos Delay. Programmable Silence Inhibit. Two No’s of programmable inputs. Battery low audio, visual warning. Three programmable Form C relay for Fire, Fault and Supervisory. Primary Power 120 / 220 VAC+10% - 15%, 60/50 Hz. Standby Power 24V DC (2Nos. of 12V 40Ah Max, built in for 12Ah) Sealed Lead acid battery operation condition operation temperature 0 - 49º C / 32 - 120º F Relative Humidity 93 ± 2% RH (Non-condensing) at 32 ± 2º C /90 ± 3º F and including taking down old unserviceable panel nd fixing at existing location complete all as specified as directed by Engineer in Charge.
Make: Ravel Electronics Pvt Ltd. / Honey Well / Ceasefire Industries Pvt. Ltd Make: Ravel/HONEYWELL/CEASEFIRE INDUSTRIES PVT LTD | 2 | EACH JOB | 53,550 ₹1.1 L | 1,25,000 ₹2.5 L | 67,900 ₹1.4 L |
Updated dates
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
28 Nov 2025, 6:00 pmClosed
Lt Col Sumukh Swaroop
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No 1 Jamnagar 361003
REPAIR/ MAINT OF FIRE ALARM SYSTEM WITH MISC ITEMS OF TECH ACCN UNDR GE (AF) JAMNAGAR NO 1
2025_MES_737924_1
8376/E8
Open Tender
Miscellaneous Works
180 days
JAMNAGAR
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No 1
₹36,000
Yes
6 Feb 2026
31 Oct 2025
29 Nov 2025
31 Oct 2025
28 Nov 2025
14 Nov 2025
Material & Labour in repair for sub main wiring with 2 run single core multistranded copper conductor cable of size 2.5 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke ), drawn through and including mild steel ERW conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 2.5 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete all as specified as directed by Engineer in Charge. Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment.
Material & labour in repair for Point wiring with 2.5 sqmm(22/.3mm) PVC insulated and unsheathed FRLS single core multistranded copper conductor for one light/fan/bell point in and including PVC rigid non metallic concealed conduit 19/20 mm dia, medium duty, ISI Marked to be terminated in modular metal box , modular fittings etc including 2.5 sqmm (22/.3 mm ) PVC insulated and unsheathed FRLS single core multistranded copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment complete all as specified as directed by Engineer in Charge.
Supply and fixing in repair modular Socket 6A/16A - 2/3 pin combined 2 module complete all as specified as directed by Engineer in Charge.
Supply and fixing in repair Modular switch 1 way 16A, 1 module complete all as specified as directed by Engineer in Charge.
Supply and fix in repair MCB’s single pole, 6 to 32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete all as specified as directed by Engineer in Charge.
Supply and fix in repair MCB’s single pole & neutral, 6-32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete all as specified as directed by Engineer in Charge.
M&L for Checking, inspecting and finding of faults in looping, siren, wiring, panel working of existing fire alarm system from OEM engineers and rectification of defects. Control electrical wiring connected to fire alarm sytem including programming of panel/module smoke detector etc complete all as specified as directed by Engineer in Charge.
M&L for checking/testing of fire alarms system complete incuding checking of all connection, between each module upto panel all as specified and as directed by Engr -in- charge. Note (i) Cost of replacement of any module i.e smoke detector, MCB, Siren to be paid under relevant items. (ii) Testing should be done in 03 Places/points of each location or as directed by Engr-in-charge)
Supply, installation, commissioning and testing of Analogue Addressable Fire Alarm Control Panel including detector wise configuration facility 200 Event storage with Real Time Clock, upto 192 grouping facility, Pre Alarm Action, Programmable Detector sensivity. Device type verification, Earth fault annunciation facility at 0 ohms, Double Address Sensing, Loop wise device test, 40 x 4 characters LCD display 4 numbers of loop card and 254 devices in any combination per loop. Day / Night mode facility. USB 2.0 interface for PC connectivity. Rs. 485 Communication facility for Network / Repeater / MODBUS / BACnet. Programmable Auto Silence Facility. Programmable AC Loos Delay. Programmable Silence Inhibit. Two No’s of programmable inputs. Battery low audio, visual warning. Three programmable Form C relay for Fire, Fault and Supervisory. Primary Power 120 / 220 VAC+10% - 15%, 60/50 Hz. Standby Power 24V DC (2Nos. of 12V 40Ah Max, built in for 12Ah) Sealed Lead acid battery operation condition operation temperature 0 - 49º C / 32 - 120º F Relative Humidity 93 ± 2% RH (Non-condensing) at 32 ± 2º C /90 ± 3º F and including taking down old unserviceable panel nd fixing at existing location complete all as specified as directed by Engineer in Charge. Make: Ravel Electronics Pvt Ltd. / Honey Well / Ceasefire Industries Pvt. Ltd Make: Ravel/HONEYWELL/CEASEFIRE INDUSTRIES PVT LTD
Supply, installation, commissioning and testing in repair of 2 Zone Conventional Gas Realease Panel complying with BS EN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector including taking out old unserviceble panel and fixing at existing location complete all as specified as directed by Engineer in Charge. Make: Ravel Electronics Pvt Ltd. / Honey Well / Ceasefire Industries Pvt. Ltd Make: Ravel/HONEYWELL/CEASEFIRE INDUSTRIES PVT LTD
Supply, installation, testing and commissioning Fire alarm control panel complying with BS EN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector and modules complete all as specified as directed by Engineer in Charge. Make: Ravel/HONEYWELL/CEASEFIRE INDUSTRIES PVT LTD
Supply, installation and commissioning and testing of loop Card which will have 254 devices of both detectors and modules in a single line circuit, SLC supports both class A and class B wiring complete all as specified as directed by Engineer in Charge. Make: Ravel/HONEYWELL/CEASEFIRE INDUSTRIES PVT LTD and including taking down old unserviceable
Supply, installation and commissioning and testing of Addressable Smoke and heat detector with base with Binary coded address setting. Dual Led's for 360 visibilty. Sleek low-profile housing design. Regular 100mm base. IP rating: Ip-42 complete all as specified as directed by Engineer in Charge. Make: Ravel/HONEYWELL/CEASEFIRE INDUSTRIES PVT LTD and including taking down old unserviceablee
Supply, installation and commissioning and testing of Addressable manual call point - Resettable type-with back box with binary coded address setting with status LED for 360 visibilty- IP 50 Rating complete all as specified as directed by Engineer in Charge. Make: Ravel/HONEYWELL/CEASEFIRE INDUSTRIES PVT LTD and including taking down old unserviceable
Supply, installation and commissioning and testing of conventional type Horn wall mounted type rated at 100 dBA@ 1m for audible annunciation complete all as specified as directed by Engineer in Charge. Make: Ravel/HONEYWELL/CEASEFIRE INDUSTRIES PVT LTD and including taking down old unserviceable
Supply, installation and commissioning and testing of fault isolator Module capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected all as specified as directed by Engineer in Charge. Make: Ravel/HONEYWELL/CEASEFIRE INDUSTRIES PVT LTD and including taking down old unserviceable
Supply and fix in repair of Addressable Control Module for monitoring the field devices. Binary coding setting Approval UL listed complete all as specified as directed by Engineer in Charge Make: Ravel or equivelent Note:- Need to connect with sounder as External power supply required
S&F in repair of Batteries DC, 12V, 7 AH, lead acid duly initial charged complete including taking down old unserviceable battery complete all as specified as directed by Engineer in Charge. Make:Exide/Amaron/Microteck/Luminious
Supply and fixing in replacement of Fire Alarm Sounders / Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of + 5 DB 1500 m range complete all as specified as directed by Engineer in Charge
Supply and fixing in replacement of Fire Alarm Sounders / Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of + 5 DB 3500 m range complete all as specified as directed by Engineer in Charge
Supply and fixing in replacement of of push button for fire alarm sirens complete all as specified as directed by Engineer in Charge
Supply and fixing in replacment PVC insulated, PVC sheathed single core multistranded copper conductor cable of size of FRLS cable 1.5 sqmm 4 core complete all as specified as directed by Engineer in Charge.
Supply and fixing in replacement of Crash/gong bell 9 inches to be fixed on wall complete all as specified as directed by Engineer in Charge
Supply and fixing in replacement of stove enamelled black MS conduit 20mm dia ISI marked on ceiling or recessed as required & repairing & making good the same disturbed surfaces and including taking down old unserviceable complete all as specified as directed by Engineer in Charge
Supply and fixing in replacement of PVC insulated, PVC sheathed two core multistranded copper conductor cable of size 1.5 Sqmm FRLS complete all as specified as directed by Engineer in Charge
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
PS.pdf
Tender Documents • 0.88 MB
BOQ_826271.xls
BOQ • 2.41 MB
Download all tender documents and submit your bid