Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹393.0 CrAccepted-AOC | ₹393.0 Cr | 1 | Accepted-AOC L1 Bidder |
| 2 | 2₹405 CrRejected-Finance 401 THE GRAND MALL OPP STATE BANK ZONAL OFFICE S M ROAD AMBAWADI AHMEDABAD 380015 | AHMADABAD | GUJARAT | 380015 | ₹405 Cr | 2 | Rejected-Finance L2 Bidder |
| 3 | 3₹409.4 CrRejected-Finance 605 607 6 FLOOR SHRIKANT CHAMBERS PHASE 1 6 FLOOR ADJACENT TO R K STUDIOS MUMBAI 400071 MAHARASHTRA INDIA | ₹409.4 Cr | 3 | Rejected-Finance L3 Bidder |
Tender Value
Refer Docs
EMD Value
₹3.9 Cr
Closing Date
23 Feb 2024, 3:00 pmClosed
MD and Group CEO, GIFTCL
EPS Building 49A, Block 49, Zone 4, Gyan Marg, GIFT City, Gandhinagar, Gujarat, 382355
Construction of Fintech building at GIFT City, Gujarat
2024_GIFTC_184852_1
CW-01
Open Tender
Civil Works - Buildings
1095 days
As per Tender Document
As per Tender Document
4 documents required · 4 mandatory
₹10,000
Gujarat International Finance Tec-City Company Lim
₹3.9 Cr
16 Mar 2024
7 Feb 2024
23 Feb 2024
7 Feb 2024
23 Feb 2024
7 Feb 2024
Amount
1200007313 C - EXCAVATION -ALL DEPTHS - LEAD l.5KM Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means (if required) for all type of soil in both dry and wet conditions, sand, gravel, hard Murrum / completely weathered rock, all area, all depth including removal of stumps of trees of girth of all sizes, shuttering, shoring, strutting or any other safe methods for protection of excavated surface, dressing of sides and ramming of bottom, and transporting the excavated material within a lead of 1.5 KM radius, stacking, spreading and levelling, etc. as per detailed technical specifications and as directed by Engineer-in-charge. Note - a. Plan area of base PCC as per structural drawing shall be measured for payment (unless otherwise specified). Contractor shall quote the rate for excavation with additional quantity for surrounding working space (which shall not be paid) b. Rate shall be inclusive of dewatering work (if required) while any earth work activity in under water condition or during rain or due to any other reason.
1200007314 C - FILLING - EXCAVATED SOIL- 20CM LAYER Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, for all lead and lifts, including dewatering (pumping out water/ mud) etc complete as per detailed technical specifications and as directed by engineer in charge.
1200007315 C - FILLING - RIVER SAND/ CRUSHED SAND Supplying and filling in plinth with river sand/ manufactured sand conforming to Zone - V, for all lead and lifts under floors/ in plinth etc including, watering, _a_m_ming consolidating and dressing complete as per detailed technical specifications and as directed by engineer in charge.
1200007316 C-PRE-CONSTRUCTION ANTI-TERMITE TREATMNT Providing and injecting Chemical emulsion for PRE - CONSTRUCTIONAL anti-termite treatment and creating a chemical barrier on the top surface of plinth filling, inside junction of wall and floor, on top of damp proof course or on masonry at level of plinth filling as per IS 6313 (Part-2)-2013 using chemical like lmidacloprid 30.5% SC (CIB approved) and proportion of dilution with water shall be as per manufacturer's specification. The emulsion shall be applied as mentioned below, all as per detailed technical specifications and directions of Engineer-in-charge. Plinth area in plan at GF shall only be measured and paid. A guarantee bond of 10 years shall be furnished in prescribed proforma. Rate shall be inclusive of material required for Anti Termite Treatment and labour and equipment's required for applying in any condition all etc. complete as directed by engineer in charge. (Stage of treatment may be vary as per site condition. Contractor shall be approved by Engineer in charge before execution.) a) Treatment to soil below raft- Before laying the rubble soling and PCC, the compact and levelled soil shall be treated at 5 liters per sq m. OR In case of soils/sand filled above the raft, the treatment at 5 liters per sq m shall be carried out on the top surface of filled soil/sand. b) Treatment to soil along the retaining wall - The soil retained by the walls (soil coming in contact with retaining wall) shall be treated at the rate of 7.5 liter per sq m of the vertical surface in full depth. c) Treatment of soil along external perimeter of building- After the building is complete, the earth along the external perimeter of the building shall be rodded at intervals of 150 mm and to a depth of 300 mm. The rods should be moved backward and forward, parallel to the wall to break up the earth and emulsion poured along the wall at the rate of 7.5 liter per square meter of vertical surfaces. d) Top surface of the plinth filling including damp proof courses at the rate of 5 liter /sqm of internal plinth area (if required)( As per IS:6313 Part 11-2013). For any area without basement, treatment shall be done as per IS:6313 Part-11-2013. e) Treatment of soil surrounding pipes, wastes and conduits - When pipes, wastes and conduits enter the soil inside the area of the foundation, soil surrounding the point of entry shall be loosened around each of such pipe, waste or conduits for a distance of 150mm and up to a depth of 75 mm before the treatment is commenced. When they enter the soil external to the foundation, they shall be similarly treatment for a distance of 300 mm, unless they stand clear of the walls of the building are about 75 mm. f) 1 liter/ linectr meter alon unction of wall and floor at all stages g) 2 litre per linear meter for expansion joints in touch with soil/sand. Plinth area of Ground Floor of the building shall be considered for payment in sqm.
1200007318 C - P&L - RUBBLE SOLING -AVG 230MM THK Providing and laying rubble soling in foundation and for plinth protection, of average 230 mm thickness (compacted), filling, covering and levelling the surface with a layer of sand after filling the voids (up to 25%) with smaller sized black trap stones 20-40mm, 40-63mm, 63-90, 90-150mm size of stone/ metals or stone chips, including watering, dewatering (pumping or bailing out water/ mud and removing slush) ramming well and consolidating each layer by plate compactor /static roller/vibratory roller of required capacity for all lead and lifts/ depth as per detailed technical specifications and as directed by Engineer-in charge
1200007319 C - P&F-TMT BARS INCL. COUPLER - FE 550D Reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding (with GI wire) all complete for all leads and lifts, all level, all floors including the basement. Reinforcement work shall be including lapping, providing necessary chairs,pins, spacers and also including Providing and fixing parallel threaded couplers/ reducer conforming to IS :16172 on to reinforcement bars including threading, enlargement at connection by forging, protecting the prepared reinforcement bars and related operations as required to complete the works as per detailed technical specifications and as per direction of Engineer in-Charge. Position of coupler shall be approved by Engineer in charge. Contractor shall use SAIL, TATA (TISCO), RINL, JSW steel, JSPL tmt bars make for the work and couplers of sanfield, dextra, halfen moment, G-tech or equivalent approved make. Thermo-Mechanically Treated bars TMT (Fe 550 D) No separate payment for chairs, laps, pins, spacers, wastage and binding wire will be made.
1200007320 C - P&L - RCC INCLUDING FORMWORK - M25 Providing and laying in position ready mixed design mix cement concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate as per CPWD/BIS specifications, Portland Pozzolana/ Portland Slag cement,·admixtures in recommended proportions as per IS:9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, dewatering (if required), curing, carriage for all leads, centering and shuttering; but excluding the cost of reinforcement as per direction of engineer in charge; for all floor, all height/ depth, all level etc. all complete as per detailed technical specifications and as directed by Engineer-in-charge. Note- 1) This item shall also include cost of transportation of concrete from plant to site and within site. 2) Item includes cost of cement as approved in design mix. Nothing extra shall be paid or recovered on account of quantity of cement. 3) All type of shuttering shall be designed by contractor and submitted to Engineer in charge along with design calculations (if required) for approval. Shuttering shall be executed as per approved shop drawing and design calculation. No extra payment for the above. 4) Rate shall be inclusive of dewatering (if required) while any construction activity in under water condition. 5) Rate shall be inclusive of providing grooves, drip moulds, pockets, cut-outs etc. and co-ordination of insert sleeves, insert plate(cost of insert plate shall be paid separately), encasing if any wherever required while casting for all level all height. 6) PPC (Pozzolana Portland Cement) shall be used for all concrete work having minimum 25% fly ash content as per Green building norms except in self compacting concrete (SCC). 7) Any Special formwork/ provisions, if required, for SCC shall be provided by the contractor and nothing extra shall be payable on this account. Concrete of M 25 grade
1200007321 C - P&L - RCC INCLUDING FORMWORK - M30 Providing and laying in position ready mixed design mix cement concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate as per CPWD/BIS specifications, Portland Pozzolana/ Portland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, dewatering (if required), curing, carriage for all leads, centering and shuttering; but excluding the cost of reinforcement as per direction of engineer in charge; for all floor, all height/ depth, all level etc. all complete as per detailed technical specifications and as directed by Engineer-in-charge. Note- 1) This item shall also include cost of transportation of concrete from plant to site and within site. 2) Item includes cost of cement as approved in design mix. Nothing extra shall be paid or recovered on account of quantity of cement. 3) All type of shuttering shall be designed by contractor and submitted to Engineer in charge along with design calculations (if required) for approval. Shuttering shall be executed as per approved shop drawing and design calculation. No extra payment for the above. 4) Rate shall be inclusive of dewatering (if required) while any construction activity in under water condition. 5) Rate shall be inclusive of providing grooves, drip moulds, pockets, cut-outs etc. and co-ordination of insert sleeves, insert plate(cost of insert plate shall be paid separately), encasing if any wherever required while casting for all level all height. 6) PPC (Pozzolana Portland Cement) shall be used for all concrete work having minimum 25% fly ash content as per Green building norms except in self compacting concrete (SCC). 7) Any Special formwork/ provisions, if required, for SCC shall be provided by the contractor and nothing extra shall be payable on this account.Concrete of M 30 grade
1200007322 C - P&L - RCC INCLUDING FORMWORK - M35 Providing and laying in position ready mixed design mix cement concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate as per CPWD/BIS specifications, Portland Pozzolana/ Portland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, dewatering (if required), curing, carriage for all leads, centering and shuttering; but excluding the cost of reinforcement as per direction of engineer in charge; for all floor, all height/ depth, all level etc. all complete as per detailed technical specifications and as directed by Engineer-in-charge. Note- 1) This item shall also include cost of transportation of concrete from plant to site and within site. 10 2) Item includes cost of cement as approved in design mix. Nothing extra shall be paid or recovered on account of quantity of cement. M3 3) All type of shuttering shall be designed by contractor and submitted to Engineer in charge along with design calculations (ifrequired) for approval. Shuttering shall be executed as per approved shop drawing and design calculation. No extra payment for the above. 4) Rate shall be inclusive of dewatering (if required) while any construction activity in under water condition. 5) Rate shall be inclusive of providing grooves, drip moulds, pockets, cut-outs etc: and co-ordination of insert sleeves, insert plate(cost of insert plate shall be paid separately), encasing if any wherever required while casting for all level all height. 6) PPC (Pozzolana Portland Cement) shall be used for all concrete work having minimum 25% fly ash content as per Green building norms except in self compacting concrete (SCC). 7) Any Special formwork/ provisions, if required, for SCC shall be provided by the contractor and nothing extra shall be payable on this account.Concrete ofM 35 grade
1200007323 C - P&L - RCC INCLUDING FORMWORK - M40 Providing and laying in position ready mixed design mix cement concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate as per CPWD/BIS specifications, Portland Pozzolana/ Portland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, dewatering (if required), curing, carriage for all leads, centering and shuttering; but excluding the cost of reinforcement as per direction of engineer in charge; for all floor, all heig ht/ depth, all evel etc. all complete as per detailed technical specifications and as directed by Engineer-in-charge. Note - 1) This item shall also include cost of transportation of concrete from plant to site and within site. 2) Item includes cost of cement as aooroved in design mix. Nothing extra shall be paid or recovered on account of quantitv of cement 3) All type of shuttering shall be designed by contractor and submitted to Engineer in charge along with design calculations (if required) for approval. Shuttering shall be executed as per approved shop drawing and design calculation. No extra payment for the above. 4) Rate shall be inclusive of dewatering (if required) while any construction activity in under water condition. 5) Rate shall be inclusive of providing grooves, drip moulds, pockets, cut-outs etc. and co-ordination of insert sleeves, insert plate(cost of insert plate shall be paid separately), encasing if any wherever required while casting for all level all height. 6) PPC (Pozzolana Portland Cement) shall be used for all concrete work having minimum 25% fly ash content as per Green building norms except in self compacting concrete (SCC). 7) Any Special formwork/ provisions, if required, for SCC shall be provided by the contractor and nothing extra shall be payable on this account.Concrete of M 40 grade.
1200007324 C - P&L - RCC INCLUDING FORMWORK - M45 Providing and laying in position ready mixed design mix cement concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate as per CPWD/BIS specifications, Portland Pozzolana/ Portland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, dewatering (if required), curing, carriage for all leads, centering and shuttering; but excluding the cost of reinforcement as per direction of engineer in charge; for all floor, all height/ depth, all level etc. all complete as per detailed technical specifications and as directed by Engineer-in-charge. Note - 1) This item shall also include cost of transportation of concrete from plant to site and within site. 2) Item includes cost of cement as approved in design mix. Nothing extra shall be paid or recovered on account of quantity of cement. 3) All type of shuttering shall be designed by contractor and submitted to Engineer in charge along with design calculations (if required) for approval. Shuttering shall be executed as per approved shop drawing and design calculation. No extra payment for the above. 4) Rate shall be inclusive of dewatering (if required) while any construction activity in under water condition. 5) Rate shall be inclusive of providing grooves, drip moulds, pockets, cut-outs etc. and co-ordination of insert sleeves, insert plate(cost of insert plate shall be paid separately), encasing if any wherever required while casting for all level all height. 6) PPC (Pozzolana Portland Cement) shall be used for all concrete work having minimum 25% fly ash content as per Green building norms except in self compacting concrete (SCC). 7) Any Special formwork/ provisions, if required, for SCC shall be provided by the contractor and nothing extra shall be payable on this account.Concrete of M 45 grade.
1200007325 C - P&L - RCC INCLUDING FORMWORK - M50 Providing and laying in position ready mixed design mix cement concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate as per CPWD/BIS specifications, Portland Pozzolana/ Portland Slag cement,.admixtures in recommended proportions as per IS:9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site. of laying, dewatering (if required), curing, carriage for all leads, centering and shuttering; but excluding the cost of reinforcement as per direction of engineer in charge; for all floor, all height/ depth, all level etc. all complete as per detailed technical specifications and as directed by Engineer-in-charge. Note- 1) This item shall also include cost of transportation of concrete from plant to site and within site. 2) Item includes cost of cement as approved in design mix. Nothing extra shall be paid or recovered on account of quantity of cement. 3) All type of shuttering shall be designed by contractor and submitted to Engineer in charge along with design calculations (if required) for approval. Shuttering shall be executed as per approved shop drawing and design calculation. No extra payment for the above. 4) Rate shall be inclusive of dewatering (if required) while any construction activity in under water condition. 5) Rate shall be inclusive of providing grooves, drip moulds, pockets, cut-outs etc. and co-ordination of insert sleeves, insert plate(cost of insert plate shall be paid separately), encasing if any wherever required while casting for all level all height. 6) PPC (Pozzolana Portland Cement) shall be used for all concrete work having minimum 25% fly ash content as per Green building norms except in self compacting concrete (SCC). 7) Any Special formwork/ provisions, if required, for SCC shall be provided by the contractor and nothing extra shall be payable on this account.Concrete of M 50 grade.
1200007326 C - P&L - RCC INCLUDING FORMWORK - M60 Providing and laying in position ready mixed design mix cement concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate as per CPWD/BIS specifications, Portland Pozzolana/ Portland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairiag strength; including pumping of concrete to site of laying, dewatering (if required), curing, carriage for all leads, centering and shuttering; but excluding the cost of reinforcement as per direction of engineer in charge; for all floor, all height/ depth, all level etc. all complete as per detailed technical specifications and as directed by Engineer-in-charge. Note - 1) This item shall also include cost of transportation of concrete from plant to site and within site. 2) Item includes cost of cement as approved in design mix. Nothing extra shall be paid or recovered on account of quantity of cement. 3) All type of shuttering shall be designed by contractor and submitted to Engineer in charge along with design calculations (if required) for approval. Shuttering shall be executed as per approved shop drawing and design calculation. No extra payment for the above. 4) Rate shall be inclusive of dewatering (if required) while any construction activity in under water condition. 5) Rate shall be inclusive of providing grooves, drip moulds, pockets, cut-outs etc. and co-ordination of insert sleeves, insert plate(cost of insert plate shall be paid separately), encasing if any wherever required while casting for all level all height. 6) PPC (Pozzolana Portland Cement) shall be used for all concrete work having minimum 25% fly ash content as per Green building norms except in self compacting concrete (SCC). 7) Any Special formwork/ provisions, if required, for SCC shall be provided by the contractor and nothing extra shall be payable on this account.Concrete of M 60 grade
1200007327 C - P&L - SELF COMPACTING CONCRETE - M50 Providing and laying in position, machine batched and machine mixed, design mix Ready mix Self Compacting Cement Concrete (SCC) produced in fully automatic batch mixed plant of M50 grade as per approved design mix using Ordinary Portland cement with adding cementitious material like fly ash, GGBFS/ Alccofine/ silica fume etc. (approximate 20%). Design mix shall be approved by Engineer in charge. SCC shall be with a slump flow of 650-750 mm at pouring in site (6 hrs from batching) with minimum density of 2350Kg/m3. Viscosity shall be 6 to 12 seconds measured in V Funnel and pass ability shall be ≥ 0.9 measured in an L Box (3 rebar) at mix design/ development in the laboratory for Fair Finished reinforced cement concrete work in super structure at all floor levels, including transportation of concrete through transit mixer to site of laying, dewatering (pumping or bailing out water/ mud and removing slush), finishing, curing, vibrating (if required) for all leads, all floor levels, all height, pumping of concrete to site of laying, including admixtures conforming to IS 9103 as per designed proportions to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. The Mix design shall comply with IS 4926, IS 456 design parameters and IS 516 & BS EN 12350 testing parameters (for parameters mentioned) and shall be got approved by Engineer-in-Charge before execution of the item. The rate shall include cost of all specified materials and operations at all levels and heights, cost of centering and shuttering but exclude the cost of reinforcement which shall be paid under relevant tender item. Note - 1. This item shall also include cost of transportation of concrete from plant to site and within site. 2. Item includes cost of cement as aooroved in design mix. Nothing extra shall be paid or recovered on account of quantity of cement.
Providing and erecting staging / false floor for floor height more than 4.5 mtr. To support upper level shuttering of slab and beams / having sufficient strength to take care of wet concrete. If MS pipe "H" frames are not used for props cross and diagonal bracing of bamboos / wooden bottoms to be provided to avoid sway of stagging. Care to be taken to erect upper level probes bottom to be cut in perfect level so that it will resr completely touching the PCC top. Wooden logs are to be provided below the props. If props are short instead of using bricks as a support. Note: False floor / stagging area will be considered for only slab area (without and projection) supporting the slab / beam shuttering.
1200007328 C - FORMWORK - ARCH. EXPOSED FINISH - F3 Extra for providing and fixing formwork for Architectural exposed fair finish concrete surfaces (vertical or horizontal surface of any shape) to achieve F3 finish in 16 desired pattern and size as per drawing and specifications using laminated shuttering plywood or suitable proprietary system formwork for all types of RCC elements like slabs, walls, columns, beams, folded staircase (all sides), sill, coping, lintels, jambs, beam hunching, vertical fins, etc. including de-shuttering and neat M2 cleaning/grinding the exposed concrete surface, as directed by the engineer-in-charge. Rate shall be applicable for all levels, all height, all shapes and all elements and shall include all centering materials - form liners, ties, props, bracing, staging with necessary fixtures/ fastenings, etc. all complete as per detailed technical specifications and as directed by engineer in charge. (Note: This item shall be paid extra over the relevant items of centring and shuttering)
1200007329 C - CORE CUT IN M - UP TO 52 MM DIAMETER Providing and wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) machine of approved make for laying service lines including scaffolding, safety majors, disposing the debris, cleaning, making good, providing epoxy mortar/ micro concrete/ ready mix polymer modified oatch repair mortar/ Non shrink grout for concrete for grouting the gaps around the pipes for all levels/ all height, after approval of engineer in charge, etc. all complete as per detailed technical specifications and as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorized approved agency. Scanning of reinforcement shall be carried out before core cutting if required and as suggested by Engineer in charge. Location of core cutting shall be approved by Engineer in charge. Up to 52 mm dia
1200007330 C - CORE CUT IN M - 53 TO 77MM DIAMETER Providing and wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) machine of approved make for laying service lines including scaffolding, safety majors, disposing the debris, cleaning, making good, providing epoxy mortar/ micro concrete/ ready mix polymer modified patch repair mortar/ Non shrink grout for concrete for grouting the gaps around the pipes for all levels/ all height, after approval of engineer in charge, etc. all complete as per detailed technical specifications and as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorized approved agency. Scanning of reinforcement shall be carried out before core cutting if required and as suggested by Engineer in charge. Location of core cutting shall be approved by Engineer in charge. Beyond 52mm dia up to 77 mm dia
1200007331 C - CORE CUT IN M - 78 TO 102MM DIAMETER Providing and wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) machine of approved make for laying service lines including scaffolding, safety majors, disposing the debris, cleaning, making good, providing epoxy mortar/ micro concrete/ ready mix polymer modified patch repair mortar/ Non shrink grout for concrete for grouting the gaps around the pipes for all levels/ all height, after approval of engineer in charge, etc. all complete as per detailed technical specifications and as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorized approved agency. Scanning of reinforcement shall be carried out before core cutting if required and as suggested by Engineer in charge. Location of core cutting shall be approved by Engineer in charge. Beyond 77mm dia up to 102 mm dia
1200007332 C - CORE CUT IN M-103 TO 152MM DIAMETER Providing and wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) machine of approved make for laying service lines including scaffolding, safety majors, disposing the debris, cleaning, making good, providing epoxy mortar/ micro concrete/ ready mix polymer modified patch repair mortar/ Non shrink grout for concrete for grouting the gaps around the pipes for all levels/ all height, after approval of engineer in charge, etc. all complete as per detailed technical specifications and as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorized approved agency. Scanning ofreinforcement shall be carried out before core cutting if required and as suggested by Engineer in charge. Location of core cutting shall be approved by Engineer in charge. Beyond 102mm dia up to 152 mm dia
1200007333 C - CORE CUT IN M- 153 TO 202MM DIAMETER Providing and wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) machine of approved make for laying service lines including scaffolding, safety majors, disposing the debris, cleaning, making good, providing epoxy mortar/ micro concrete/ ready mix polymer modified patch repair mortar/ Non shrink grout for concrete for grouting the gaps around the pipes for all levels/ all height, after approval of engineer in charge, etc. all complete as per detailed technical specifications and as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorized approved agency. Scanning of reinforcement shall be carried out before core cutting if required and as suggested by Engineer in charge. Location of core cutting shall be approved by Engineer in charge. Beyond 152mm dia up to 202 mm dia
1200007334 C - CORE CUT IN M- 203 TO 252MM DIAMETER Providing and wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) machine of approved make for laying service lines including scaffolding, safety majors, disposing the debris, cleaning, making good, providing epoxy mortar/ micro concrete/ ready mix polymer modified patch repair mortar/ Non shrink grout for concrete for grouting the gaps around the pipes for all levels/ all height, after approval of engineer in charge, etc. all complete as per detailed technical specifications and as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorized approved agency. Scanning ofreinforcement shall be carried out before core cutting if required and as suaeested bv Enzineer in charze. Location of core cutting shall be approved,by engineer in charge Beyond 202mm dia up to 252 mm dia
1200007339 C - P&F- REBARS - HILTI - 8 MM DIA Providing and fixing hilti rebars as per specification with Drilling required diameter holes up to required depth of 10 x Dia in R.C.C. members including providing & fixing rebar of required diameter H.Y.S.D. bars with L outside in the holes by injecting approved chemical HILTI grout as per designer suggestion or other approved equivalent etc. complete. Reinforcement steel to be paid separately under revalent item. The rate is inclusive of charges for Temporary Shoring, Struting including the required Scaffolding and platforms at all heights/all levels/ all floors/all shapes and sizes with all leads, conducting tests required at site as specified in Hilti method statement, etc. complete as per detailed specifications and as directed by the Engineer-in-Charge. 8 mm dia
1200007340 C - P&F - RE BARS - HILTI - 10 MM DIA Providing and fixing hilti rebars as per specification with Drilling required diameter holes up to required depth of 10 x Dia in R.C.C. members including providing & fixing rebar of required diameter H.Y.S.D. bars with L outside in the holes by injecting approved chemical HILT! grout as per designer suggestion or other approved equivalent etc. complete. Reinforcement steel to be paid separately under revalent item. The rate is inclusive of charges for Temporary Shoring, Struting including the required Scaffolding and platforms at all heights/all levels/ all floors/all shapes and sizes with all leads, conducting tests required at site as specified in Hilti method statement, etc. complete as per detailed specifications and as directed by the Engineer-in-Charge. 10mmdia
1200007341 C - P&F - REBARS - HILTI - 12 MM DIA Providing and fixing hilti rebars as per specification with Drilling required diameter holes up to required depth of 10 x Dia in R.C.C. members including providing & fixing rebar of required diameter H.Y.S.D. bars with L outside in the holes by injecting approved chemical HILTI grout as per designer suggestion or other approved equivalent etc. complete. Reinforcement steel to be paid separately under revalent item. The rate is inclusive of charges for Temporary Shoring, Struting including the required Scaffolding and platforms at all heights/all levels/ all floors/all shapes and sizes with all leads, conducting tests required at site as specified in Hilti method statement, etc. complete as per detailed specifications and as directed by the Engineer-in-Charge. 12 mm dia
1200007342 C - P&F - REBARS - HILTI - 16 MM DIA Providing and fixing hilti rebars as per specification with Drilling required diameter holes up to required depth of 10 x Dia in R.C.C. members including providing & fixing rebar of required diameter H.Y.S.D. bars with L outside in the holes by injecting approved chemical HILTI grout as per designer suggestion or other approved equivalent etc. complete. Reinforcement steel to be paid separately under revalent item. The rate is inclusive of charges for Temporary Shoring, Struting including the required Scaffolding and platforms at all heights/all levels/ all floors/all shapes and sizes with all leads, conducting tests required at site as specified in Hilti method statement, etc. complete as per detailed specifications and as directed by the Engineer-in-Charge. 16 mmdia
1200007343 C - P&F - REBARS - HILTI - 20 MM DIA Providing and fixing hilti rebars as per specification with Drilling required diameter holes up to required depth of 10 x Dia in R.C.C. members including providing & fixing rebar of required diameter H.Y.S.D. bars with L outside in the holes by injecting approved chemical HILTI grout as per designer suggestion or other approved equivalent etc. complete. Reinforcement steel to be paid separately under revalent item. The rate is inclusive of charges for Temporary Shoring, Struting including the required Scaffolding and platforms at all heights/all levels/ all floors/all shapes and sizes with all leads, conducting tests required at site as specified in Hilti method statement, etc. complete as per detailed specifications and as directed by the Engineer-in-Charge. 20 mmdia
1200007344 C - P&F - REBARS - HILTI - 25 MM DIA Providing and fixing hilti rebars as per specification with Drilling required diameter holes up to required depth of 10 x Dia in R.C.C. members including providing & fixing rebar of required diameter H.Y.S.D. bars with L outside in the holes by injecting approved chemical HILTI grout as per designer suggestion or other approved equivalent etc. complete. Reinforcement steel to be paid separately under revalent item. The rate is inclusive of charges for Temporary Shoring, Struting including the required Scaffolding and platforms at all heights/all levels/ all floors/all shapes and sizes with all leads, conducting tests required at site as specified in Hilti method statement, etc. complete as per detailed specifications and as directed by the Engineer-in-Charge. 25 mm dia
1200007345 C - P&F - RE BARS - HILTI - 32 MM DIA Providing and fixing hilti rebars as per specification with Drilling required diameter holes up to required depth of 10 x Dia in R.C.C. members including providing & fixing rebar of required diameter H.Y.S.D. bars with L outside in the holes by injecting approved chemical HILTI grout as per designer suggestion or other approved equivalent etc. complete. Reinforcement steel to be paid separately under revalent item. The rate is inclusive of charges for Temporary Shoring, Struting including the required Scaffolding and platforms at all heights/all levels/ all floors/all shapes and sizes with all leads, conducting tests required at site as specified in Hilti method statement, etc. complete as per detailed specifications and as directed by the Engineer-in-Charge. 32 mm dia
1200007346 C-P&F PERFORATED HI RIB SHEET- 0.9MM THK Providing and laying construction joint /concrete grade seperation joint with 0.9mm thick perforated hi rib m.s. sheet. with the joints preparation so that reinforcement fixing continues uninterrupted including centering & shuttering wherever required. The only striking required to hold the position, and any steel rebar /props supports can used as backing, all complete as per detailed specifications and as directed bv the Engineer-in-Charge.
1200007347 C - BRICK MASONRY - ALL LEVELS - CM 1:5 Providing and laying brick work using common burnt clay conventional building bricks conforming to IS 1077-1992 having compressive strength not less than 35Kg/cm2 with cement mortar 1:5 (1 cement: 5 course sand) in any shape and thickness including raking out of joints on both the sides, finishing, curing, scaffolding for all floor, all height/ depth all level etc. complete as per detailed specifications and as directed by engineer-in-charge.
1200007348 C - HALF BRICK MASONRY-ALL LEVELS-CM 1:4 Providing and laying half brick masonry using common burnt clay conventional building bricks conforming to IS 1077-1992 having compressive strength not less than 35 Kg/cm2 with cement mortar 1:4 (1 cement: 4 course sand) in any shape including raking out of joints on both the sides, finishing, curing, scaffolding for _?II floor, all height/ depth all level etc. complete as per detailed specifications and as directed by engineer-in-charge.
1200010001 P&L - AAC BLOCK MASONRY - SUPERSTRUCTURE Providing and laying Autoclaved Aerated Concrete Block Masonry in super-structure above plinth level with RCC band at sill level, lintel level and any other level with approved block laying polymer modified adhesive mortar including all material, labour, tools, tackles, scaffolding, etc. at all levels all complete as per drawings, specifications and as directed by the Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
1200007349 C - PROVIDING & FIXING - GLASS BRICKS Providing and fixing 190 ± 5 mm x 190 ± 5 mm x 80 ± 5 mm glass bricks of approved make and design (any pattern) with polymer based white cement mortar 1:2 (1 white cement: 2 sand+ white marble dust). 2 numbers of 5 mm thick GI wires shall be embedded in all the sides of glass brick by drilling holes in PVC spacers in each joint horizontal as well as vertical and GI wire shall be grouted with periphery of openings by drilling holes, in periphery, and filling the same with chemical (re-barring) grout ofapproved make. The PVC concealed spacer (with provision for passing the 2no. GI wires in horizontal and vertical direction) shall be provided to maintain grooves/ spaces for GI wire and polymer white cement mortar at the junction/ groove of two glass bricks including curing. The sample of the glass brick shall be got approved by Engineer-in-Charge. The glass bricks shall be fixed with placing GI wires vertically as well as horizontally after passing through the spacer and having minimum lap length of +200mm as per the site conditions at all the places, all heights, all level and in all shapes, etc. complete, as per approved shop drawing and as directed by Engineer-in-charge. Joints along the periphery of glass bricks shall be filled with approved make and colour weather silicone sealant of approved make. All the grooves between the glass brick shall be smoothly finished with paste /putty ofwhite cement and polymer for water tightness. The shade and size ofthe glass bricks shall be as approved by Engineer in charge. Contractor shall prepare shop drawing as per site condition and get approved by Engineer in charge. Required MS framing work shall be paid in relevant tender item. The actual exposed area of zlass brick work, on one face only, shall be measured for payment purpose.
1200007354 C - P&F - WOODEN FLUSH DOOR - Providing and fixing wooden flush door having aluminum extruded frame of approved make conforming to IS: 733 and IS: 1285 having polyester powder coating (minimum thickness of polyester powder coating 50 micron), fixing with SS 304 dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc., Aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, pressure cleat, crimping angle, aluminum snap beading for glazing/ panelling, SS 304 screws, provision of PVC shims minimum 5 mm thick with backer rod and silicone sealant (both side), dash fastener, wooden infill in frame for hardware provision etc complete., Shutter made of factory made and pressed flush door shutter of 35mm thick (bare finish) shutter, made of ISi marked non decorative type flush door shutters, core of block board construction with frame of 1st class hard wood, pine filler and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters having 1.0mm thick laminates of approved make, shade, finish on both faces of shutter fixed with phenol / formaldehyde synthetic resin type adhesive conforming to IS 848 including providing and fixing external lipping with 6 mm wide as per finish shutter made out of 1st class teak wood battens, exposed on all edges of door shutter as required with PU polishing on three exposed faces of lipping etc, Vision panel made of 5 mm thick toughen glass of any shape any size in all type of flush door shutter. Glass shall be fixed with first class teak wood beading on both side the door as per drawing including cutting door, provision of glass, extra batten support required around periphery of opening, PU polishing, etc complete including all necessary hardware like Floor spring, Door closer, Hinges, Mortise Dead Lock, Handle, Tower bolt, Flush tower bolt, Door Buffer, Door seal, etc. all complete as per detailed specifications and as directed by Engineer-in-charge.
Providing and fixing fire doors with 2 hour fire rating conforming to IS: 3614 (Part 2), BS 476 (Parts 20 & 22), ISO 834 ; 45 mm thick fully flush, double skin door shell with lock seam joints at stile edges made from 1.25 mm thick galvanized steel sheet including door frames made from 1.6 mm thick galvanized steel sheet formed to double rebate profile of size 143 mm x 57mm as per manufacturer's instructions, door frames and shutter primed with Zinc Phosphate stoving Primer and finished with Polyurethane Aliphatic grade or epoxy paint including ironmongery consisting of stainless steel ball bearing butt hinges 3 mm thick fixed flush to the frame and shutter, full width horizontal handles (panic bar), concealed flush bolts, door closers, other standards fixtures and fasteners, etc. complete for the following clear opening sizes: Item to include all necessary fixtures and fastenings [ fire rated ] including heavy duty SS hinges min 4 per shutter, tower bolts, door stoppers, handles, mortise lock, push plates, kick plates, door closers, etc. Complete.
1200007361 C - P&F - TOILET CUBICLE SYSTEMS Providing and fixing wall supported/ top hanging (without bottom support) toilet cubical systems of approved make in required size partition and door width with 18mm thick antibacterial, antifungal compact laminate sheet (conforming to JIS 22801:2010 and ASTM G21-2015 standards respectively) with Green guard Certification, including doors, pilasters & intermediate panels, which shall be resistant to heat, bacteria, water, chemical, scratch, termite and impact. Compact board shall be resistance to water immersion through permissible increase on thickness and mass <0.60% and board density >l.35kg/cm3 and manufactured under EN438-2&3:2005 standard. Compact panel shall be of approved shade, texture and make. The top supporting system shall be run above the ceiling. To strengthen and support the system and it shall be settled on end walls with MS member. Mid panels and Pilaster will be fixed with box top support of SS (316 grade). The intermediate panels will be attached to the wall with the help of approved SS channels (grade316) and all required hardware, made up of stainless steel as per manufacturer's specification. Door knob, gravity hinges, Thumb turn locksets with occupancy indicators, coat hooks with door stopper, U channel, top rail with corner connector, adjustable foot/ pedestal, Rubber noise deafening tape, screw & wall plugs shall be approved under the instruction of Engineer-in-charge. All screw shall be of SS 316 grade in satin finish. All pilasters are supported by SS 306 bottom cladding. The floor with a clearance height up to 110 mm. Cubical shall be procured and install from system manufacturers and not self made and assembled. Dimensions of the cubical system shall be as per conceptual drawing and as per site condition. Contractor shall prepare shop drawing with all hardware and accessories for approval before execution. Work shall be carried out as per approved shop drawing. Note:- Total Area of Board (used in door or in front or in partition) shall be measured for payment which will include cost of all material, labour, fixing, hardware, SS fittings, SS pilasters mentioned in the item, except MS work, which if required, for suspending cubicle system, shall be paid in relevant item.
Providing, making & fixing polished granite stone coving of specified height and breadth, machine cut from granite stone cube. The farthest point of coving’s height and breadth shall be connected by an arc of circle having radius 30mm to 35mm, jointed with epoxy mortar, corner pieces, mirror polishing, etc. complete. Measurement shall be on the basis of actual length of coving provided.
1200007363 C - PLASTER - 1 COAT MALA- 12 TO 15MM Providing and laying 12 to 15 mm thick single coat mala finish plaster on wall in CM 1:3 (1 cement: 3 Coarse sand) including hexagonal chicken mesh of size aperture 20 mm x 20 mm of 22 gauge 200mm wide on sides of brick work/ blocks wall/ RCC work (with application of bonding agent/ hacking of RCC surface) at all floors, all shapes and all heights with necessary scaffolding, finishing (smooth finished with steel trowel), curing, making grooves, forming pattas, hacking properly RCC surface etc. complete as per detailed specifications and as directed by Engineer-in-charge. Note- 1) Rate shall be inclusive of any D'J)e of groove and drip mould in all type of plaster work for all floor, aUlevel, all height.
1200007364 C - PLASTER - 2 COAT MALA- 15 TO 18MM Providing & laying 15 to 18mm thick double coat mala finish cement plaster on sides of wall including hexagonal chicken mesh of size aperture 20 mm x 20 mm of 22 gauge 200mm wide on sides of masonry work/ block wall / RCC wall (with application of bonding agent/ hacking of RCC surface) at all heights, all shapes and all levels with 8-10mm thick first coat in CM 1:4 (1 cement: 4 coarse sand) by spraying and second coat upto 6 mm of CM 1:3 (1 cement: 3 fine sand) with mala finish plaster (smooth finished with steel trowel) at all floors, all shapes and all height including hacking to RCC surface, scaffolding, finishing, curing, making grooves, forming pattas and drip mould, etc. complete as per detailed specifications and as directed by Engineer-in-charge. ; Note- 1) Rate shall be inclusive of any type of groove and drip mould in all type of plaster work for all floor, all level, all height
1200007365 C - PLASTER- 1 COAT CEMENT FINISH-10MM Providing and laying average 10mm thick single coat cement finish cement plaster in CM 1:4 (1 Cement: 4 Coarse Sand) on ceilings and stair soffits at all floors, all shapes, all heights with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface/ application of bonding agent, with floating coat of cement slurry etc. complete as per detailed specifications and as directed by Engineer-in-charge. Note- 1) Rate shall be inclusive of any type of groove and drip mould in all type of plaster work for all floor, all level, all hejght.
1200007366 C - GYPSUM PLASTER-1 COAT -AVG 12MM THK Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 254 7 (Part - 1 & II) 1976, applied on smooth / uneven background such as bare brick/ block/ RCC work on walls of any shape any size at all floors, all height and locations, finished in smooth line and level including provision of 145 GSM Fiberglass mesh with alkali resistant coating as per manufacturer's specifi ations, scaffolding etc. complete. Bonding agent shall be applied on concrete surface before plastering work. Fiber glass mesh shall be fixed at beams and column joints with wall, plumbing and lectrical work chasing areas t corner and d window joints. Rate shall be inclusive of bonding agent application, glass fiber mesh, gypsum plaster and finished coat, provision of groove as per drawing, scaffolding for all floor, all height all level etc complete as per detailed specifications and as directed by Engineer-in-charge.
1200007367 C - P&L - HDPE MEMBRANE WP - BELOW RAFT Providing & laying under the RCC Raft Foundation, a HDPE based waterproofing white composite sheet membrane, of minimum 1.2mm thickness (bare HDPE membrane without adhesive/sand etc), when tested as per ASTM D 3767, consisting of high density polyethylene film/sand blasted surface, a pressure sensitive adhesive and a trafficable weather resistant coating. The membrane shall form an integral, adhesive and permanent bond to poured concrete to prevent water migration at the interface of the membrane and structural concrete and shall include dual adhesive tape lap seam technology to complete side laps and secure adjacent sheets. HDPE Membrane shall be applied with following steps and as per manufacturer recommendation: 1) Cleaning of PCC surface to remove dust, loose particles, etc with compressed air or any other suitable technique depending on site conditions, grinding any sharp edges, etc and in case of any indetatations repair with SBR Latex polymer mortar/microconcrete. 2) HDPE Membrane laid over the PCC and continued over the side of raft, vertical portion of retaining wall and over the kicker joint, and terminated over the kicker joint, into a saw cut groove provided at an angle of 45 degrees to the vertical, to tuck in the HDPE membrane and sealed off with a PU sealant. 3) Rate shall be inclusive of surface preparation, repairing, injection grouting, saw cutting of construction joints and filling with patch repair mortar, making polymer mortar /Polymer CC fillets at horizontal as well as vertical corners etc complete. Rate shall be inclusive of testing of elements and system before and after water proofing application. 4) All construction joints coming under waterproofing membrane/ coating shall be treated with non shrink cementitious grout, by injection grouting and cost of same shall be considered to be inclusive all waterproofing items. 5) Latest technical system/ product shall be adopted at the time of execution. The membrane shall have the following physical properties: 1) Lateral Water Migration Resistance of at least 70 mas per ASTM D 5385, of hydrostatic head pressure 2) An elongation of> 400% as per ASTM D 412. 3) Tensile Strength> 25 MPa as per ASTM D 412, 4) Peel Strength to Poured-in-Place Concrete after 7 days of water immersion: >800N/m -ASTM D 903 5) Lap peel adhesion> 1400 N/m; ASTM D1876 6) The membrane shall have a puncture resistance > 890 N as per ASTM E 154, 7) Water presence less than 0.1 perms as per ASTM E 96 Method B 8) Water absorption not exceeding 0.5% as per ASTM D 570. The manufacturer must be ISO 9001 & 14001 certified and valid certificates must be produced as proof. Contractor shall submit methodology statement with typical sections and get approved from engineer in charge before start of work , application shall be carried out by manufacturer or approved and certified applicator of manufacturer. Actual laid area of HDPE membrane only shall be measured for payment with out considering any overlaps. Cost includes all material, labour, T&P, wastage, etc. Note: 1) All the waterproofing treatment/ work shall be executed through an approved water- proofing agency ofapproved manufacturer and/or Engineer In Charge. 2) Contractor shall submit technical data sheet of each product, which will be used for execution. Contractor shall submit methodology statement with all detail in illustrative sketch form and get approved from Engineer in charge. 3) Awritten guarantee on non-judicial stamp paper (tri-party) shall be submitted by the main Contractor and manufacturer/ applicator, who has carried out work for a minimum period of ten years from the certified date of completion for the satisfactory performance of the entire water-proofing system. 4) Special type of water proofing shall be executed under supervision of technical team of manufacturer. Testing shall be approved by engineering in charge before proceeding for ubsequent activities.
1200007369 C - P&L- HDPE MEMBRANE WP - WALLS Providing & laying HDPE based waterproofing white composite sheet membrane, of minimum 1.2mm (bare HDPE membrane without adhesive/sand etc) thickness, when tested as per ASTM O 3767, consisting of high density polyethylene film/sand blasted surface, a pressure sensitive adhesive and a trafficable weather resistant coating. The membrane shall form an integral, adhesive and permanent bond to poured concrete to prevent water migration at the interface of the membrane and structural concrete and shall include dual adhesive tape lap seam technology to complete side laps and secure adjacent sheets. HDPE Membrane shall be applied with following steps and as per manufacturer recommendation: 1) Cleaning of backing surface to remove dust, loose particles, etc with compressed air or arty other suitable technique depending on site conditions, grinding any sharp edges, etc 2) HDPE Membrane laid over the levelled wall surface and continued over the side of raft, and over lapping on the raft membrane into a saw cut groove provided at an angle of 45 degrees to the vertical, to tuck in the HOPE membrane and sealed off with a PU sealant possessing a minimum Shore 'A' Hardness of 40. The membrane shall deliver the following physical properties: 1) Lateral Water Migration Resistance of at least 70 mas per ASTM O 5385, of hydrostatic head pressure, 2) An elongation of minimum 400% as per ASTM O 412, 3) Tensile Strength > 25 MPa as per ASTM O 412, 4) Peel Adhesion to Concrete in accordance with ASTM O 903 shall give a result of> 800 N/m, 5) Lap peel adhesion of membrane laps shall be 880 N/m, as per ASTM O 1876. 6) Puncture resistance not less than 890 N as per ASTM E 154, 7) Water presence less than 0.1 as per ASTM E 96 Method B 8) Water absorption not exceeding 0.5% as per ASTM D 570. The manufacturer must be ISO 9001 & 14001 certified and valid certificates must be produced as proof. Contractor shall submit methodology statement with typical sections and get approved from engineer in charge before start of work , application shall be carried out by manufacturer or approved and certified applicator of manufacturer. Actual laid area (horizontal & vertical laying) of HDPE membrane shall be measured for payment without considering overlaps.Cost includes all material, labour, T&P, wastage involved as mentioned in the item. Note: 1) All the waterproofing treatment/ work shall be executed through an approved water- proofing agency of approved manufacturer and/or Engineer In Charge. 2) Contractor shall submit technical data sheet of each product, which will be used for execution. Contractor shall submit methodology statement with all detail in illustrative sketch form and get approved from Engineer in charge. 3) A written guarantee on non-judicial stamp paper (tri-party) shall be submitted by the main Contractor and manufacturer/ applicator, who has carried out work for a minimum period of ten years from the certified date of completion for the satisfactory performance of the entire water-proofing system. 4) Special type ofwater proofing shall be executed under supervision oftechnical team of manufacturer. Testing shall be approved by engineering in charge before proceeding for subsequent activities.
1200007370 C-POOJUM WATERPROOFING-POLYUREA MEMBRANE Providing and applying hot spray applied Root-Resistant crack bridging, elastomeric, fast curing, 2 component hybrid polyurea waterproofing membrane system, spray applied to achieve a dry film thickness of 1.5 mm- 2mm by a two-part hot spray equipment after the application of epoxy primer on the prepared surface with a consumption of 0.8 -1.2 kg/sqm depending on the porosity and undulations of the surface. The waterproofing membrane must be applied in minimum 2 coats after application of epoxy based primer,the waterproofing membrane having the following key performance properties and conforming to standards andapprovals as mentioned 1. Solid content >99% 2.Tensile strength >10 N/mm2 as per ASTM 0412 3 Shore A hardness> 75 (after 28 days) as per ASTM 02240 4 Elongation at break(%)> 400% as per ASTM 0412 5 Tear Strength> 45 N/mm as per ASTM 0624C 6 Thermal resistance - The elastic properties are maintained at temperatures as low as -20°C. 7.Resistance to fire to std (EN 13501-1) Class E. The supplier must have their own manufacturing facility, should not be private label product or sourced from third party. The manufacturer must be ISO 9001 & 14001 certified. Contractor shall submit methodology statement with typical sections and get approved from engineer in charge before start of work, application shall be carried out by manufacturer or approved and certified applicator of manufacturer. Actual consumption of polyurea material should not be less than the theoritical consumption of such materials prescribed by the manufacturer in their latest standard published literature or more as mentioned in the item, to achieve mentioned desired minimum thickness The polyurea coating shall be applied over the concrete haunches (to be provided at corners) in M 25 on the periphery of the parapet wall- mother slab, all around, and well above the height ofthe soil overburden to provide complete protection.A separation layer of non woven geo textile of minimum 300 gsm shall be provided over polyurea membranewith with proper overlaps of minimum 100 mm. Protective concrete screed with saw cut and groove shall be provided in desired slope, which shall be paid under relevant tender item. Providing & placing polypropylene HOPE dimpled drain board (with inbuilt geo textile drainage membrane of 120 gsm at top), compressive strength not less than 200 KN per sqm with minimum overlap of 50 mm, based on soil characteristics and height of soil overburden. Supplying and applying protective geo textile fabric of 300 gsm over the entire dimpled drain board with proper overlaps of minimum 100 mm. Cost includes all materials, labour, T&P, wastage etc. as mentioned in the item except cost of protective concrete screed, which shall be paid under relevant item. only actual applied area of polyurea coating as per required thickness without any overlaps and wastage only shall be measured for payment. Note: 1) All the waterproofing treatment/ work shall be executed through an approved water- proofing agency of approved manufacturer and/or Engineer In Charge. 2) Contractor shall submit technical data sheet of each product, which will be used for execution. Contractor shall submit methodology statement with all detail in illustrative sketch form and get approved from Engineer in charge. 3) A written guarantee on non-judicial stamp paper (tri-party) shall be submitted by the main Contractor and manufacturer/ applicator, who has carried out work for a minimum period of ten years from the certified date of completion for the satisfactory performance of the entire water-proofing system. 4) Special type of water proofing shall be executed under supervision of technical team of manufacturer. Testing shall be approved by engineering in charge before proceeding for subsequent activities.
1200007371 C - P&M INTEGRAL WATERPROOFING ADMIXTURE Providing and mixing integral crystalline admixture for waterproofing treatment to RCC structures like basement raft, retaining walls, sewage & water treatment plant, tunnels/ subway etc. at the time of transporting of concrete into the drum of the ready-mix truck/ at RMC plant as per direction of Engineer in charge, using integral crystalline admixture @ 0.80% (minimum to the weight of cement content per cubic meter of concrete) or recommended by the manufacturer's specification in reinforced cement concrete at site ofwork. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per detailed specifications and as per the direction of the engineer incharge. The product perfomance shall carry guarantee for 10 years against any leakage.
1200007372 C - P&A - INTEGRAL WATERPROOFING SLURRY Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry: 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry: 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI - 212-3R-2010 i.e. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The product performance shall carry guaranteed for 10 years against any leakage. Actual consumption of crystalline material should not be less than the theoritical consumption of such materials prescribed by the manufacturer in their latest standard published literature or more as mentioned in the item to achieve mentioned desired minimum thickness. The work shall be carried out all complete as per detailed specifications and as per the direction of the engineer-in-charge.
1200007373 C - P&A - P U BASED WATERPROOFING SYSTEM Providing and applying single component, elastomeric, pitch modified PU coating water proofing system to be applied at consumption of minimum 1.5 kg/sqm to achieve a minimum 1.2 mm DFT with required 2 or more coats (minimum 2 coat) uniformly spread in entire area. System shall be executed as follows: 1) Surface preparation as per manufacturer specifications to make it laitance, dust and sludge free, removing any extended portions by grinding using suitable equipments and provding basic repair including filling of any defects like cracks or potholes with Latex modifed mortar shall be done. 2) Making fillet/ provision of corner tape 3) PU primer application as per manufacturer recommendation 4) Pitch PU waterproofing can be applied by roller, spray or short hair brush in 2 or more coats. PU waterproofing shall be taken covering entire parapet wall up to min 300mm height. 5) Laying Geotextile (non-woven polyester) membrane/glass fibre membrane in thckness as recommended by water proofing system provider, with a min of 100mm wide overlap and on typical locations like wall & floor junctions, rain water down take etc., 6) Protection screed laid to slope, which shall be paid in relevant tender item. The pitch modified PU coating system must deliver the following properties: 1) Tensile Strength (without intermediate membrane) - >1.5 N/mm2 2) Crack bridging capacity - > 1.5 mm 3) Elongation at break> 400% as per ASTM D 412 Cost includes all material, labour, T&P, wastage involved as mentioned in the item except protection concrete screed, which shall be paid under relevant item separately. Actual consumption of pitch PU material should not be Jess than the theoritical consumption of such materials prescribed by the manufacturer in their latest standard published literature or more as mentioned in the item,to achieve mentioned desired minimum thickness. All auxiliary & accessories involved during application should be supplied by single manufacturer as a part of system. Actual applied area of pitch PU coating with required thickness without any overlaps and wastage only actual applied surface area (horizontal and vertical surface) shall be measured for payment. Note: 1) All the waterproofing treatment/ work shall be executed through an approved water- proofing agency of approved manufacturer and/or Engineer In Charge. 2) Contractor shall submit technical data sheet of each product, which will be used for execution. Contractor shall submit methodology statement with all detail in illustrative sketch form and get approved from Engineer in charge. 3) A written guarantee on non-judicial stamp paper (tri-party) shall be submitted by the main Contractor and manufacturer/ applicator, who has carried outwork for a minimum period of ten years from the certified date of completion for the satisfactory performance of the entire water-proofin system. 4) Special type ofwater proofing shall be executed under supervision of technical team of manufacturer. Testing shall be approved by engineering in charge before proceeding for subsequent activities.
1200007374 C - P&A- ELASTOMERIC WATERPROOF COATING Providing and applying Two-component acrylic polymer modified cementitious elastomeric waterproof coating (minimum 1.5 mm thickness) having minimum 1 N/mm2 tensile strength, at minimum 1.5mm thickness OFT, having consumption of approx 2 kg/ sqm per mm of thickness. The coating shall have an elongation of a minimum of 80% when tested as per ASTM D 412 and having crack bridging ability of not less than 1.5 mm. Thorough surface preparation by mechanical means to level and plain the surface of walls and floors of the toilet areas. All cracks and crevices to be filled using polymer mortar and made good to receive waterproofing coating treatment The coating shall cover all the floor area of the wet area (toilet) and be applied over on to the vertical walls for required height above the floor in two or more coats to achieve required thickness. The periphery of the toilet floor shall be additionally reinforced with an extra third coat of the coating with a fiber band (glass fibre mesh of minimum 80 gsm) sandwiched between the first and the second coat, which shall also done around protrusions (pipes) meant for plumbing purpose. The last coat when wet, shall be sprinkled with clean and washed sand, to facilitate the floor screed or plaster. Actual consumption of 2 component cementitiious elastomeric acrylic material should not be less than the theoritical consumption of such materials prescribed by the manufacturer in their latest standard published literature or more as mentioned in the item,to achieve desired mentioned minimum thickness. The manufacturer must be ISO 9001 & 14001 certified and must have their own manufacturing facility, should not be private label product or sourced from third party. Pipes being fixed for plumbing shall be fixed in holes which are mechanically core cut, more than the dia of the pipes. Pipes shall be fixed by grouting the annular space with non-shrink cementitious grout of proprietary make. Before grouting the pipes shall be wrapped with a two-way self adhesive tape at least 2 inches wide and then grouted to fill in the grout, ensuring total watertight plumbing fittings. Contractor shall submit methodology statement with all detail in illustrative sketch form and get approved from Engineer in charge. Application shall be carried out by manufacturer or approved applicator of manufacturer. Actual applied area of 2 component cementitious elastomeric coating (horizontal and vertical) as per required thicknes only shall be measured for payment. Cost includes all material, labour, T&P, wastage involved as mentioned in the item. Note: 1) All the waterproofing treatment/ work shall be executed through an approved water- proofing agency of approved manufacturer and/or Engineer In Charge. 2) Contractor shall submit technical data sheet of each product, which will be used for execution. Contractor shall submit methodology statement with all detail in illustrative sketch form and get approved from Engineer in charge. 3) A written guarantee on non-judicial stamp paper (tri-party) shall be submitted by the main Contractor and manufacturer/ applicator, who has carried out work for a minimum period of ten years from the certified date of completion for the satisfactory performance of the entire water-proofing system. 4) Special type ofwater proofing shall be executed under supervision oftechnical team of manufacturer. Testing shall be approved by engineering in charge before proceeding for subsequent activities.
1200007375 C - PROVIDING & FILLING-AAC BATS Providing and filling light weightAAC bats (of size 40-60 mm) with cement mortar mixed in the ratio 1:3:6 (1 cement: 3 coarse sand: 6 AAC block bats) including mixing of approved water proofing compound in recommended proportion. The laid brick bat mix shall be well rammed and compacted as required. Further surfaces shall be screeded with cement concrete mix 1:1.5:3 (1 cement: 1.5 coarse sand: 3 stone grit of size 6 mm and below by volume) admixed with approved integral water proofing compound in recommended proportion, laid to an average thickness of 25mm and finished smooth or ready to receive finish material as specified. Care shall be taken prior to filling all pipes passing through sunk portion such that the pipes are pressure tested by maintaining pressure for 24 hours and junctions of pipes passing through walls, slabs are well grouted and sealed. This shall be tested by ponding water for required depth and maintaining for 72 hours.(Rate includes cost of AAC bats, cement mortar, top screed, labour charges for working at all levels, leads and heights). For payment the area of sunken slab and the depth of filling including the thickness of screed shall be measured.
1200007376 C - P&F - WATER STOP BAR- 20MM X 10MM Providing and applying of controlled swellable type water stop bar (20 mm x 10 mm), non-bentonite type (expansive nature) of approved make for construction joints treatment of RCC structure, such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc. For provision of swellable bar, contractor shall provide shear key in wall and raft. After cleaning the shear key, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint as per manufacturer specification. Over the primed surface swellable type water stop bar shall be placed. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage. Cost includes all above mentioned labour, material, T&P, accessories, wastage etc Length of actual paced swellable water bar without any wastage only shall be measured for payment purposes
1200007377 C- P&L BRICK BAT COBA-AVG 11SMM THK Providing and laying conventional (India Type) cement based brickbat coba water proofing treatment average 115mm thick and minimum thickness at khurra/ channel as 65 mm including preparation of surface as required for treatment on roofs, balconies, terraces etc. at all floors consisting of following operations and furnishing a guarantee bond in prescribe format of 10 years between main contractor, client and approved water proofing agency. 1) Cleaning and applying a cement slurry at the rate 2.75 Kg per sqm mixed with water proofing compound as manufacture's specification as directed by engineer in-charge over the slab including adjoining walls upto 300mm height including testing the surface, grouting the cracks if leakage is found before the treatment. 2) Laying brick bats with mortar using broken bricks/ brick bats 25 mm to 115mm size with maximum 50% of cement mortar of mix 1:5 admixed with water proofing compound conforming to IS: 2645 in minimum 20 mm thick layer of beading cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. 3) After three days of proper curing applying a second coat of cement slurry at the rate 2.75 Kg per sqm admixed with water proofing compound conforming to IS : 2645 including laying glass fibre cloth of approved quality in top layer of plaster and finally Finishing the surface to make wired finish/ trowel finish with average 12-20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. 4) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done as oer detailed specifications and as directed by Engineer-in-charge. (Only plan area shall be measured, vata shall not be measured separately and paid for.)
1200007378 C - P&L - CHINA MOSAIC FLOORING Providing & laying china mosaic flooring for plain and curved surfaces, comprising of 20 to 25 mm size broken white/ colour pieces of ceramic/glazed tiles laid over 12 to 15mm thick cement mortar 1:6 (1 cement: 4 coarse sand) bedding including applying cement slurry at the rate of 2.75 kg per sqm on plain or sloped surfaces with joints not exceeding 5 mm, including filling the gaps with white cement mixture & mixing with synthetic polyester fibre, triangular in shape having specific gravity of 1.34 to 1.40, cross section size ranging from 10 to 40 micron & length upto 6mm, mixing fibre @ 125 grams per 50kg of cement in cement mortar, including providing and mixing water proofing material in mortar @ 1 kg per SO kg of cement, all complete as per direction of Engineer-in-charge. The flooring shall be tampered with wooden rammer not exceeding 2 Kg in weight to bring the mortar up to the surface, including rounding of the junctions and extending them upto 15 cm. along the parapet wall. The rate shall include bands, if different colour is used, any pattern or design as per drawing and direction, making vata/ fillet, curing, cleaning with water and oxalic acid, etc. complete as per detailed specifications and as directed by Engineer-in-charge. Only Plan area shall be measured for payment.
1200007379 I C - P&L - GRANITE FLOORING - 18MM THICK Providing and laying mirror Polished Granite stone flooring, to various areas in required design and patterns, in any shape and size, all complete as per the architectural drawings, with 18 mm thick stone slab laid over approximate SO mm thick cement mortar 1:4 (1 cement : 4 sand)/ concrete screed (1:2:4) and fixed with grey cement and colour pigment in proportion to match the shade of stone/ cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477 of thickness 6mm of approved make, including providing groove up to 5mm, grouting with epoxy grout of approved make and shade rubbing, curing and polishing etc. all complete as per detailed specifications and as directed by the Engineer-in-Charge. Rate shall be inclusive of granite (as per approved sample), adhesive for fixing, epoxy grouting, polishing etc complete.
1200007385 C - P&L - TREMIX CC PAVEMENT- M25 Providing and laying C.C. pavement of mix M-25 with ready mixed/ batch mixed concrete from batching plant with floor harderner(as per manufacturer specification). The ready mixed concrete shall be casted in panel and finished with screed board vibrator, vacuum dewatering process and finally finished by floating, brooming with machine, etc. complete as per detailed specifications and directions of Engineer in charge. If trimix concrete shall be laid over on existing concrete surface, bonding agent shall be applied before laying of concrete. Reinforcement if required shall be paid in relevant tender item. The rate shall include cutting of grooves and filling them with poly sulphide sealent and beker rod.
1200007389 C - P&L - VITRIFIED TILE - FLOORING Providing and laying vitrified floor tiles in required sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours, shades, texture/ finish (matt/ anti skid/ satin/ polished/ glossy), laid over approximate SO to 60 mm thick cement mortar 1:4 (1 cement : 4 sand)/ concrete screed (1:2:4) and fixed with grey cement and colour pigment in proportion to match the shade of stone/ cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477 in minimum 6mm thickness of approved make, including providing groove up to 5mm, grouting with epoxy grout of approved make and shade rubbin,g, curing and finishing etc. all complete as per detailed specifications and as directed by the Engineer-in-Charge. Rate shall be inclusive of vitrified tile (as per approved sample), bedding mortar/ screed, adhesive for fixing, epoxy grouting etc complete.
1200007390 C - P&L - VITRIFIED TILE- DADO & SIMILAR Providing and laying Vitrified tiles in any sizes, any colours, any shade and texture/ finish (matt/ anti skid/ satin/ polished/ glossy) with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in wall tile/ dado, skirting, riser of steps, laid on plastered surface (wall shall be plastered with cement mortar 1:3) and jointed with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 154 77, providing groove up to 5mm between tile, grouting with epoxy grout of approved make and shade including curing, rubbing, finishing etc complete for all floor all height all level and as directed by Engineer in charge. Rate shall be inclusive of vitrified tile (as per approved sample1, backing coat plaster, adhesive for fixing, epoxy grout etc complete.
1200007395 C - P&L - RECTIFIED GLAZED CERAMIC TILES Providing and laying rectified Glazed Ceramic floor and wall tiles of size 300 x 300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS: 15622, of approved make, in any colours (as approved) laid on floor 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), in dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with and jointed with cement based high polymer modified quick-set tile white adhesive (Water based) conforming to IS: 154 77, providing groove up to 5mm between tile, grouting with epoxy grout of approved make and shade including curing, rubbing, finishing, etc complete for all floor all height all level as per detailed specifications and as directed by Engineer in charge. Rate shall be inclusive of Glazed ceramic tile (as per approved sample), bedding mortar/ screed, backing coat plaster, adhesive for fixing, grout etc complete.
1200007411 C- MOULD RESIST PAPERLESS GYPSUM CEILING Providing and fixing suspended minimum 12.5mm thick paperless, modified, glass fiber reinforced gypsum core with enhanced moisture and mould resistance as per EN 15283 Part -1, Thermal Conductivity: 0.3 (w/mQK) Thermal Resistance: 0.042 m2K/W for Mould Resistance: Confirms to ASTM D3273 Water Resistance: Confirms to EN520 type Hl, Edge type: All 4 square/ tapered edges board. Suspension and grid system shall be made out of GI (IS-513), YS-260Mpa, Finish-Galvanized150GSM (IS-277) and Serrated pattern or knurled/ Chequered/ ribbed sections. Ceiling includes perimeter Channel of 0.5 mm is fixed along the perimeter of existing wall with the help of (6x40) impact anchor of approved make at 600mm centers. Ceiling angle 0.5 mm is suspended by fixing it to the soffit cleat. Soffit cleat and raw plug shall be of CR1 grade (Is-513), zinc coating (7 to 8 microns) and 08 x 45mm having pull out load- 6.8kN creating 1200mm x 1200mm grid. Intermediate channel 0.9 is fixed to the ceiling angle 0.5mm with M6 x 12mm hex bolt & hex nut arrangement (Material-As per EN 10083 Finish - Zinc Plating) or with 2 Nos of 04.2x13 metal to metal screw made out of carbon steel as per EN-ISO I 7049/50 having minimum 4 micron zinc coating. • The ceiling section is then fixed to the intermediate channel with the help of connecting clip (Material-High carbon spring steel wire (BS970 Gr.En 42, 46-48 HRC, Finish-Zinc plating 4-6 micron) and in direction perpendicular to the intermediate channel at 600mm c/c. Single layer Gypsum board shall be fixed to ceiling section with 25mm drywall screws having material-carbon steel EN-ISO 7049/50. The boards to be jointed and finished with Jointing compound recommended filler, jointing tapes, finisher (Conforms to ASTM C475) to achieve flush look, and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cut-outs made with frame of perimeter channels suitably fixed for all floor, all level all height all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of putty and painting. In ceiling, drop down patta (visible) beyond 300 mm, shall be measured and separately paid in Sqm. Contractor shall prepare shop drawing with coordination of all services and opening/ excess. Sample, shop drawing and mock up shall be approved by Engineer in charge. Installation shall be carried out by approved installer and material of suspension system shall be as per manufacturer specifications. Out to out plan area of mould resistance gypsum ceiling system shall be only measured for payment purposes without any deductions for lights, diffusers, columns etc. Nothing extra shall be paid for making provisions for providing light, diffusers, AC grill, fire alarm, sprinkler system and other such fittings.
1200007410 C - P&F - MODULAR GRID TILE CEILING Providing and fixing eco-friendly light weight calcium silicate false ceiling tiles having Tegular edge &15 mm Thick Densified edges on the Tile Periphery for Extra Strength The Light weight calcium silicate ceiling tiles shall have, light reflection 85% non-combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity0.043°w/m KC.for the best thermal Insulation. The Light weight calcium Silicate tile shall be of approved texture Fine fissured/ Spintone/Cosmos having NRC value of 0.5 & Globe having NRC value of 0.75 NRC or equivalent of size 595 X 595 mm to be laid on true horizontal level suspended inter locking metal grid of hot dipped galvanized steel sections (galvanizing @120 grams per sqm including both side) consisting of main T' runner suitablyspaced at joints to get required length and size of 24X38mm made from 0.30 mm thick (minimum) sheet, 1200mm centre to centre, and cross 'T' of size 24X28mm made out of 0.33mm (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of raw] plugs at 450 mm centre to centre with 25 mm long dry wall screws@ 230 mm interval and layin_g 15 mm h nsified edges calicum silicate ceiling tiles of approved texture in the grid,
1200007408 C- P&F- FABRIC &ACOUSTIC PANELLING Providing and fixing of 12-13.5 mm thick Acoustic and Sound Absorption Panel System, of required size, manufactured from 100% polyester fibers/ poly propylene/ polyethylene terephthalate panel. Fibers Needle punched and thermally bonded in a non - woven matrix semi rigid specifically tooled and pressed for maximum sound absorption, with 70% NRC (0.70 NRC) and meets the British Fire Rating Standards BS 476 standard Class lY, Class P, Fire Propagation index= 9.2, with 0.006% moisture absorption (will not rot or smell) in grey and white colour fibers, which is UV stabilized, non allergic and non toxic. Acoustic and Sound Absorption Panel System is to be fixed on existing GI/ CRS framework, which shall be fixed into wall and which shall create true line and level with screws, fixed horizontally or vertically (as per architectural design). On the GI/ CRS framing, required thickness of ply (as per item specification and paid separately) shall be fixed to receive the acoustic panel. Acoustic and Sound Absorption Panel System shall be covered with a tightly stretch open cell fabric over the entire panel including all sides. Designer Fabric with acoustic and fire retardant properties (Basic rate - Rs.2,000/ Sqm) of approved make and shade as per the drawing in pattern of specified size and as per approved sample shall be covered on acoustic panel for wall panelling in required pattern with all necessary stitching, adhesives, screws etc. Rate shall also be inclusive of superior class PU polished teak wood beading of required size all around the exposed edges of panel, labour, necessary hardware, adhesives required, etc. but excluding the cost of GI/ metal framing, base ply and Specified polish over the all surfaces of wooden member. The rates shall be inclusive of all wastages, fixing in position for all heights, all floors, scaffolding etc. complete as per detailed specifications and to the satisfaction of the Engineer in-charge. Only elevation area of the fabric cladded acoustic panel within the teak wood beading shall be measured and paid in sqm.
1200007409 C - P&F - FIRE RESISTANT GYPSUM CEILING Providing and fixing false ceiling at all height for all floor, all level etc including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 150 gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener as per design, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.l. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.l. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of raw plugs at 450 mm centre, with 25mm long dry wall screws@ 230 mm interval, including fixing of 12.5 mm thick Fire resistent Glass Reinforced Gypsum (GRG) Boards (Confirming to BS476) complying to IS: 2095 : 2011 to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification. In ceiling, drop down patta (visible) beyond 300 mm, shall be measured and separately paid in Sqm. Rate shall also include the cost of making openings for light fittings, grills, diffusers, cut-outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting
1200007419 C- P&A-WHITE CEMENT PUTTY-AVG 1MM THK Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface including thoroughly brushing the surfaces with sand paper to make it free from mortar dropping and other foreign matter (to prepare the surface even and smooth), scaffolding for all floor, all level, all height etc. complete as per detailed specifications and as per directions of Engineer-in-Charge.
1200007420 C- P&A-ACRYLIC WATER BASED PRIMER Providing and applying priming coats with modified acrylic, water-based alkali resistant primer with silicone additives having low VOC of approved make, having I low VOC (Volatile Organic Compound ) content on specified area as per manufacturer's specifications and as per approved sample by appropriate tools for all level, all floor, all height etc complete as per detailed specifications and as directed by Engineer-in-charn
1200007421 C-P&A-INT. ACRYLIC EMULSION PAINT-2 COAT Providing and applying Wall and ceiling painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than SO grams/ litre with highly washable, Anti fungal, anti bacterial, scratch resistant and scrub resistance property of approved make and shade, in Two coats including applying additional coats wherever required to achieve even shade and colour on specified area as per manufacturer's specifications and as per approved I sample by appropriate tools for all level, all floor, all height including thoroughly brushing the surfaces with sand paper to make it free from mortar dropping and other foreign matter, scaffolding for all floor, all level, all height etc. complete as per detailed specifications and as per directions of Engineer-in-Charge.. complete up to the satisfaction of Architect and Engineer in charge. Sample shall be approved by Engineer-in-charge. Putty and primer work shall be paid in relevant tender item.
1200007424 C - P&A- WHITE WASHING WITH LIME-2 COATS White washing with lime on wall and ceiling surface (two coats) to give an even shade including thoroughly booming the surface to remove all dirt, dust; mortar drops and other foreign matter etc complete for all floors, all heights, all level as per detailed specifications and as directed by Engineer Incharge.
1200007396 C-P&F-STRUCTURAL STEEL-ALL SECTION&SHAPE Providing, fabricating, assembling, hoisting/ erecting and fixing in position at all heights/ all levels/ all floors/ all shapes & sizes with all leads & lifts using MS Rolled Steel Sections, Hollow sections, Tubular Sections, MS Plates, Chequered Plates, MS Pipes, Perforated Sheet, Flats, Bright Bars, Angles, MS Sheet, Girder, Beam, deep threaded MS bolts, threaded J bolts, insert plate, support plate etc as per drawing. all confirming to latest relevant IS codes for the work of steel structures like staircases, railings, handrail, jali, gates, grills, bracings, platforms, brackets, monkey ladder, cattle trap, windows, pipe rack, rungs, false ceiling frame work, Roof canopy, fencing posts, bollard, M.S. Screen & fencing jali frame work etc. including straightening, cutting, bending, bolting and welding the members all as per structural drawings and as per detailed specifications (for materials & workmanship) including necessary scaffolding/ staging etc. complete in the situations described hereinafter and comprising of: i) Profile Cutting of components to required length/ width and shape/ profile; ii) Smooth grinding/ machining of edges/ faces/ all welding joints; iii) Necessary welding (electric arc welding) for required weld lengths and sizes. iv) Machine drilling of holes for joining/ anchoring (Standard measurements will be paid for as actual cut length used at site) The rate shall include dry sanding, degreasing (wet cleaning) & preparation of rustfree surface manually or mechanically, metal putty to make the surface even and smooth, 1 coat of epoxy primer of 50 to 60 micron DFT(dry film thickness) and 2 top coats of Metal PU Paint (matt finish) of having DFT 40 to 50 micron ofapproved make and shade over all the surfaces ofthe steel sections or as specified in the drawing. Note: The contractor shall be submit fabrication drawings based on construction drawings (that may be issued during construction period) for approval by the Architect/ Engineer. The fabrication work shall start only after approval ofthe fabrication drawings submited by contractor. Any change required in the fabrication drawings shall be carried out at No extra cost. Fabrication shall be in a perfect architectural workmanship manner and as provided in section V & VI of IS 800 & IS 7215. Welding shall be carried out by qualified welders/ fabricators.It should also include the cost of necessary scaffolding/ staging, zinc coated nut-bolt as required for safety, structural stability of all works at site. Note - 1. All adhesives, sealants & paint shall be with low VOC with acceptable VOC content as per GRIHA requirements and lead free. 2. Contractor shall prepare shop drawing base on concept drawing for any type of fabrication work and get approved before start the work. 3. Rate shall be for all floor, all level all height. 4. The rate shall include cost of all types of fasteners (ETA approved) to be used for fixing.
1200007432 C - P&L-PRECAST CONCRETE KERB STONES-M25 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete of any shape, any size in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand)/ external grade compatible adhesive, including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than Smm), including making drainage opening wherever required complete etc. as per detailed specifications and as per direction of Engineer-in-charge (length of finished kerb edging worked out to volume as per the approved shape, size and actually laid at site shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
1200007435 C - P&F-PRECAST RCC COVERS-100MM THK-M25 Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various design & sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways, neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick, 100 mm wide MS sheet duly painted over priming coat, reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per detailed specifications and as per direction of Engineer-in-Charge.
1200007436 C - P&L - PAVER BLOCKS- 60MM THK - M35 Providing and laying shot blasted Non- interlocking, Grey/ Colored paver blocks of 200 mm x 200mm or 200mm x 100 mm, 60 mm thick M-35 grade machine made and blasting by automatic shot blasting machine and high density of approved make for development areas as mentioned in the drawing. Including providing I and laying 50 to 80 mm thick average bedding layer of coarse sand below paver block as per required grading etc. all complete as per detailed specifications and as directed by Engineer-in-charge.. Laid paver block shall be mechanically compacted. The work of the paving blocks shall be executed in line and level by skilled mason of flooring work only. It should be laid in such a way that the no cutting of the paver block to be necessary. If cutting of paver block shall be required, than cut by machine only and laying to be done by skilled flooring mason. The Finished surface of the Paver Block shall have Coarse Sand Texture Finish. Paver blocks shall be compacted and shall be re-laid if necessary. Actual laid area shall be measured and paid without any wastage.
Providing and fixing machine cut and mirrorpolished approved coloured ITALIAN MARBLE SLAB with inlays of approvedsize,20mm +2mm thk. Of approved quality for required pattern on a bed of 1:4 CM 25mm average thickness/chemical including neat cement float,filling joints with neat coloured pigment,curing,polishing andcleaning etc.complete.
Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete.
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top,40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete
Providing and fixing mild steel grill railing weighing 15Kilogram/ Square Metre. with PVC handrail cover and newel post for staircases, including fabricating, fixtures, drilling holes in concrete / other surface, erecting the grill work, necessary welding, fixing by nuts and bolts, fixing PVC handrail cover, with one coat of anticorrosive paint and two coats of oil painting with approved colour and shade, remaking the damaged surface, cleaning, etc. complete. Spec. Number : As directed by Engineer in charge.
Providing and laying 8mm thk. Light coloured antiskid / matt ceramic tiles as specified below conforming to I.S.15622-2006 for flooring of an approved, quality, make, size and pattern /design, for flooring including cement mortar bedding of 25 mm thick in 1:4 proportion, neat cement float, cutting, leveling, jointing, filling the joints by neat cement slurry or approved colour grout, curing, finishing etc complete as directed by Engineer In Charge.
Providing and fixing 8mm thk. Light coloured glazed ceramic tiles as specified below conforming to I.S. 15622-2006 of approved quality, pattern and colour for dado in the wet area including preparing the surface and levelling in the desired line, backing of 20 thk. cement mortar in porportion 1:3 with approved waterproofing compound, square cut top edge or chamfered top edge in cement mortar 1:3, cement float, machine cutting, leveling, jointing, filling the joints with neat cement slurry or approved colour grout, finishing, curing etc complete as directed by Engineer In Charge.
Providing and fixing in position to the exact profile and prestressing the high tensile strands to specified ultimate strength, standard end anchorages, cable ducts, grouting ducts after prestressing and bearing plates with wedges as per detailed drawings including necessary plant and machinery for prestressing etc. complete. As directed by Engineer in charge.
Providing and placing in position MS sleeves (thickness as per structural consultant) for services wherever pipes pass through beam before concreting fixing in position making riveted / bolted /welded connections. All MS sleeves shall be accurately cut to the required sizes, laid as per drawing, kept in the position while laying reinforcement and shuttering, sleeves shall not get displaced while concreting, and burrs removed before laying.
Providing and applying luster of approved make (Asian/ICICI Dulux/Jotun) on external wall surface as detailed below Scrapping the surface with emery paper and wipe clean wall primer with brush with mineral turpentine with brush 8 to 10% and oil 15 to 20% with roller and allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applyingwall primer with brush with mineral turpentine 8 to 10% and oil 15 to 20% with roller Scrapping Emery paper 320 and wipe clean, interior wall finish luster 1st coat with brush/rubber/spray with mineral turpentine 7 to 9% and Oil with roller 19 to 21% After 8 hours of activity Applying 2nd coat or wall finish Lustre with mineral turpentine 7 to 9 % with brush and Oil with roller 19 to 21% after allowing dry for the period of 6 to 8 hours activity. (With prior approval of S.E.) As directed by Engineer in charge.
Dismantling of Reinforced Cement Concrete (RCC) at all levels manually/by mechanical means including cutting of reinforcement, disposal of unserviceable material at non objectional place and stacking the serviceable material upto client's store for all lead and lift including loading, unloading etc as directed by Engineer-in-charge.
Unitized Glazing System Design, fabricate, supply, protection, installation and Hand over Unitized System of structural glazing (with Open Joints Female-Female system) of Technal/schuco/Reynaers/EFP make. The Unitized glazing system constitutes of 32mm thick DGU (8mm HS+ 16 mm Air Gap+8mm Fully Toughened Glass ) glass in Vision and spandrel and Aluminium box vertical louver as shown in Tender drawings to be glazed to Aluminium frame along with structural sealant (Two part) and double adhesive tape Norton V2100 Open Cell Foam. Unitized Glazing system fixed to the host structure and not adjoining materials along with serrated Aluminium base bracket, Aluminium hook on plate, alignment bolt, as per approved design and structural required with serration plates, Teflon packing shims various thickness to adjust the levels, Aluminium base bracket fixed on RCC slab/beam and MS support (done by other) at double height and terrace with SS anchors, nut-bolt, packing shim as per structural requirement and approved by SFPL and to stand dead load as well stresses due to wind pressure etc. Expansion joint for unitized panels (vertical and horizontal) shall be as per standards and specification. Considered double bracket at terrace atrium. Anchorage allow 3 dimensional movement in anchorage (bracket) design to absorb +/-35mm host structure tolerances. The system shall be design to with stand signage fixing bracket, restrain socket fixing (supplied by BMU vender) and Lighting channel fixing arrangement. The system shall be designed pressure equalized and self drainage system. Aluminium frame and glass edge at junction should be proper fabricate and install, deviation in the line of Aluminium frame and glass edge not permitted at all level and height. Any visible undulation in the system will not be acceptable. The minimum distance between Glass edge and Aluminium glass separator should be 5mm at all level and height. All facade fixing component. Structural analysis, design and preparation of shop drawings for the specified design loads (3.1Kpa wind load and self load) conforming to NBC- 2016 volume-I. All exposed Aluminium profiles shall be Super durable Powder coating in 60 micron +/- 5 micron as per approved shade. Non- exposed Aluminium shall be chromotized. Aluminium extrusions should be of Bhoruka / Jindal / SAPA/global/ system supplier approved extruder & structural member thickness not less than 2.2 mm. All Screws, Nuts, Bolts, washers ,Anchors shall be only stainless steel of 316 grade. Hilti / Fischer Make anchor. The quote includes Aluminium flashing to seal inside and outside (Horizontal & Vertical) , corner, jamb closure & End closure with insulation, sealants, brackets, MS cantilever for double bracket, anchors fasteners, top coping with G.I. sheet water proofing membrane, M.S. H.D.G. insert if required gondola and lifting equipment and any Aluminium sub frame as required. The Contractor's quote shall be based on finished installed product as per architect design, facade Tender drawings, structural requirement and at any stage, shall not charge extra for Aluminium profile wall thickness and size dimensions, flashings, bracket, extensions, jamb closers, capping, façade installation materials, etc.
Vision Glass:24mm thick (6mm HS+12mm AG+6mm FT) DGU Glass Design, fabricate, supply, protection, installation and Hand over Unitized System of structural glazing (with Open Joints Female-Female system) of Technal/schuco/Reynaers/EFP make. The Unitized glazing system constitutes of 32mm thick DGU (8mm HS+ 16 mm Air Gap+8mm Fully Toughened Glass ) glass in Vision and spandrel and Aluminium box vertical louver as shown in Tender drawings to be glazed to Aluminium frame along with structural sealant (Two part) and double adhesive tape Norton V2100 Open Cell Foam. Unitized Glazing system fixed to the host structure and not adjoining materials along with serrated Aluminium base bracket, Aluminium hook on plate, alignment bolt, as per approved design and structural required with serration plates, Teflon packing shims various thickness to adjust the levels, Aluminium base bracket fixed on RCC slab/beam and MS support (done by other) at double height and terrace with SS anchors, nut-bolt, packing shim as per structural requirement and approved by SFPL and to stand dead load as well stresses due to wind pressure etc. Expansion joint for unitized panels (vertical and horizontal) shall be as per standards and specification. Considered double bracket at terrace atrium. Anchorage allow 3 dimensional movement in anchorage (bracket) design to absorb +/-35mm host structure tolerances. The system shall be design to with stand signage fixing bracket, restrain socket fixing (supplied by BMU vender) and Lighting channel fixing arrangement. The system shall be designed pressure equalized and self drainage system. Aluminium frame and glass edge at junction should be proper fabricate and install, deviation in the line of Aluminium frame and glass edge not permitted at all level and height. Any visible undulation in the system will not be acceptable. The minimum distance between Glass edge and Aluminium glass separator should be 5mm at all level and height. All facade fixing component. Structural analysis, design and preparation of shop drawings for the specified design loads (3.1Kpa wind load and self load) conforming to NBC- 2016 volume-I. All exposed Aluminium profiles shall be Super durable Powder coating in 60 micron +/- 5 micron as per approved shade. Non- exposed Aluminium shall be chromotized. Aluminium extrusions should be of Bhoruka / Jindal / SAPA/global/ system supplier approved extruder & structural member thickness not less than 2.2 mm. All Screws, Nuts, Bolts, washers ,Anchors shall be only stainless steel of 316 grade. Hilti / Fischer Make anchor. The quote includes Aluminium flashing to seal inside and outside (Horizontal & Vertical) , corner, jamb closure & End closure with insulation, sealants, brackets, MS cantilever for double bracket, anchors fasteners, top coping with G.I. sheet water proofing membrane, M.S. H.D.G. insert if required gondola and lifting equipment and any Aluminium sub frame as required. The Contractor's quote shall be based on finished installed product as per architect design, facade Tender drawings, structural requirement and at any stage, shall not charge extra for Aluminium profile wall thickness and size dimensions, flashings, bracket, extensions, jamb closers, capping, façade installation materials, etc.
Spandrel Insulation: Providing, fabricating, supplying and fixing in position shadow box of required size and shape, semi-rigid, inorganic, non- combustible glass wool insulation 50mm thick , density 48 Kg/m3. The insulation with one side Black veil layer shall be enclosed in 0.8mm thick powder coated G.I. sheet (with Aluminium stiffener) with adhesive, G.I. clip etc. complete as per tender drawing. Tray with insulation fixed to mullion & transom with S.S. 316 grade screws. Provide weather silicon periphery of tray. Black veil shall be glass side facing.
FIRE Stop & Smoke Seal- Providing and fixing of smoke seal insulation 2- hour fire resistant period (Integrity 120 min and Insulation 120 min ), side rise CWFS -120, insulation thickness 120 mm minimum top to bottom with factory applied impervious foil face, density minimum 80kg/m3, 10% compression at site as per manufacturer recommendation and tested standards/ make. CWFS-120 enclosed with zinc coated GI clips configured as per fire stop manufacturer’s requirements except as noted herein. Impaling clips shall be fastened to floor slab. joints between strips has to be sealed properly with Class O Aluminium fire rated tape. 1.5mm thick G.I. sheet continuous fix on R.C.C.slab and transom over insulation. ( Smoke seal system warranty minimum should be 10 Years)
BarcodeUnitized Glazing : Unitized Glazing System Design, fabricate, supply, protection, installation and Hand over Unitized System of structural glazing (with Open Joints Female-Female system) of Technal/schuco/Reynaers/EFP make. The Unitized glazing system constitutes of 32mm thick DGU (8mm HS+ 16 mm Air Gap+8mm Fully Toughened Glass ) glass in Vision and spandrel and Aluminium box vertical louver as shown in Tender drawings to be glazed to Aluminium frame along with structural sealant (Two part) and double adhesive tape Norton V2100 Open Cell Foam. Unitized Glazing system fixed to the host structure and not adjoining materials along with serrated Aluminium base bracket, Aluminium hook on plate, alignment bolt, as per approved design and structural required with serration plates, Teflon packing shims various thickness to adjust the levels, Aluminium base bracket fixed on RCC slab/beam and MS support (done by other) at double height and terrace with SS anchors, nut-bolt, packing shim as per structural requirement and approved by SFPL and to stand dead load as well stresses due to wind pressure etc. Expansion joint for unitized panels (vertical and horizontal) shall be as per standards and specification. Considered double bracket at terrace atrium. Anchorage allow 3 dimensional movement in anchorage (bracket) design to absorb +/-35mm host structure tolerances. The system shall be design to with stand signage fixing bracket, restrain socket fixing (supplied by BMU vender) and Lighting channel fixing arrangement. The system shall be designed pressure equalized and self drainage system. Aluminium frame and glass edge at junction should be proper fabricate and install, deviation in the line of Aluminium frame and glass edge not permitted at all level and height. Any visible undulation in the system will not be acceptable. The minimum distance between Glass edge and Aluminium glass separator should be 5mm at all level and height. All facade fixing component. Structural analysis, design and preparation of shop drawings for the specified design loads (3.1Kpa wind load and self load) conforming to NBC- 2016 volume-I. All exposed Aluminium profiles shall be Super durable Powder coating in 60 micron +/- 5 micron as per approved shade. Non- exposed Aluminium shall be chromotized. Aluminium extrusions should be of Bhoruka / Jindal / SAPA/global/ system supplier approved extruder & structural member thickness not less than 2.2 mm. All Screws, Nuts, Bolts, washers ,Anchors shall be only stainless steel of 316 grade. Hilti / Fischer Make anchor. The quote includes Aluminium flashing to seal inside and outside (Horizontal & Vertical) , corner, jamb closure & End closure with insulation, sealants, brackets, MS cantilever for double bracket, anchors fasteners, top coping with G.I. sheet water proofing membrane, M.S. H.D.G. insert if required gondola and lifting equipment and any Aluminium sub frame as required. The Contractor's quote shall be based on finished installed product as per architect design, facade Tender drawings, structural requirement and at any stage, shall not charge extra for Aluminium profile wall thickness and size dimensions, flashings, bracket, extensions, jamb closers, capping, façade installation materials, etc.
BarcodeUnitized Glazing : Vision Glass:24mm thick (6mm HS+12mm AG+6mm FT) DGU Glass Design, fabricate, supply, protection, installation and Hand over Unitized System of structural glazing (with Open Joints Female-Female system) of Technal/schuco/Reynaers/EFP make. The Unitized glazing system constitutes of 32mm thick DGU (8mm HS+ 16 mm Air Gap+8mm Fully Toughened Glass ) glass in Vision and spandrel and Aluminium box vertical louver as shown in Tender drawings to be glazed to Aluminium frame along with structural sealant (Two part) and double adhesive tape Norton V2100 Open Cell Foam. Unitized Glazing system fixed to the host structure and not adjoining materials along with serrated Aluminium base bracket, Aluminium hook on plate, alignment bolt, as per approved design and structural required with serration plates, Teflon packing shims various thickness to adjust the levels, Aluminium base bracket fixed on RCC slab/beam and MS support (done by other) at double height and terrace with SS anchors, nut-bolt, packing shim as per structural requirement and approved by SFPL and to stand dead load as well stresses due to wind pressure etc. Expansion joint for unitized panels (vertical and horizontal) shall be as per standards and specification. Considered double bracket at terrace atrium. Anchorage allow 3 dimensional movement in anchorage (bracket) design to absorb +/-35mm host structure tolerances. The system shall be design to with stand signage fixing bracket, restrain socket fixing (supplied by BMU vender) and Lighting channel fixing arrangement. The system shall be designed pressure equalized and self drainage system. Aluminium frame and glass edge at junction should be proper fabricate and install, deviation in the line of Aluminium frame and glass edge not permitted at all level and height. Any visible undulation in the system will not be acceptable. The minimum distance between Glass edge and Aluminium glass separator should be 5mm at all level and height. All facade fixing component. Structural analysis, design and preparation of shop drawings for the specified design loads (3.1Kpa wind load and self load) conforming to NBC- 2016 volume-I. All exposed Aluminium profiles shall be Super durable Powder coating in 60 micron +/- 5 micron as per approved shade. Non- exposed Aluminium shall be chromotized. Aluminium extrusions should be of Bhoruka / Jindal / SAPA/global/ system supplier approved extruder & structural member thickness not less than 2.2 mm. All Screws, Nuts, Bolts, washers ,Anchors shall be only stainless steel of 316 grade. Hilti / Fischer Make anchor. The quote includes Aluminium flashing to seal inside and outside (Horizontal & Vertical) , corner, jamb closure & End closure with insulation, sealants, brackets, MS cantilever for double bracket, anchors fasteners, top coping with G.I. sheet water proofing membrane, M.S. H.D.G. insert if required gondola and lifting equipment and any Aluminium sub frame as required. The Contractor's quote shall be based on finished installed product as per architect design, facade Tender drawings, structural requirement and at any stage, shall not charge extra for Aluminium profile wall thickness and size dimensions, flashings, bracket, extensions, jamb closers, capping, façade installation materials, etc.
BarcodeUnitized Glazing : Aluminium Solid Sheet Cladding Design, fabricate, supply, protection, installation and Hand over Unitized System of structural glazing (with Open Joints Female-Female system) of Technal/schuco/Reynaers/EFP make. The Unitized glazing system constitutes of 32mm thick DGU (8mm HS+ 16 mm Air Gap+8mm Fully Toughened Glass ) glass in Vision and spandrel and Aluminium box vertical louver as shown in Tender drawings to be glazed to Aluminium frame along with structural sealant (Two part) and double adhesive tape Norton V2100 Open Cell Foam. Unitized Glazing system fixed to the host structure and not adjoining materials along with serrated Aluminium base bracket, Aluminium hook on plate, alignment bolt, as per approved design and structural required with serration plates, Teflon packing shims various thickness to adjust the levels, Aluminium base bracket fixed on RCC slab/beam and MS support (done by other) at double height and terrace with SS anchors, nut-bolt, packing shim as per structural requirement and approved by SFPL and to stand dead load as well stresses due to wind pressure etc. Expansion joint for unitized panels (vertical and horizontal) shall be as per standards and specification. Considered double bracket at terrace atrium. Anchorage allow 3 dimensional movement in anchorage (bracket) design to absorb +/-35mm host structure tolerances. The system shall be design to with stand signage fixing bracket, restrain socket fixing (supplied by BMU vender) and Lighting channel fixing arrangement. The system shall be designed pressure equalized and self drainage system. Aluminium frame and glass edge at junction should be proper fabricate and install, deviation in the line of Aluminium frame and glass edge not permitted at all level and height. Any visible undulation in the system will not be acceptable. The minimum distance between Glass edge and Aluminium glass separator should be 5mm at all level and height. All facade fixing component. Structural analysis, design and preparation of shop drawings for the specified design loads (3.1Kpa wind load and self load) conforming to NBC- 2016 volume-I. All exposed Aluminium profiles shall be Super durable Powder coating in 60 micron +/- 5 micron as per approved shade. Non- exposed Aluminium shall be chromotized. Aluminium extrusions should be of Bhoruka / Jindal / SAPA/global/ system supplier approved extruder & structural member thickness not less than 2.2 mm. All Screws, Nuts, Bolts, washers ,Anchors shall be only stainless steel of 316 grade. Hilti / Fischer Make anchor. The quote includes Aluminium flashing to seal inside and outside (Horizontal & Vertical) , corner, jamb closure & End closure with insulation, sealants, brackets, MS cantilever for double bracket, anchors fasteners, top coping with G.I. sheet water proofing membrane, M.S. H.D.G. insert if required gondola and lifting equipment and any Aluminium sub frame as required. The Contractor's quote shall be based on finished installed product as per architect design, facade Tender drawings, structural requirement and at any stage, shall not charge extra for Aluminium profile wall thickness and size dimensions, flashings, bracket, extensions, jamb closers, capping, façade installation materials, etc.
FIRE Stop & Smoke Seal in BarcodeUnitized Glazing- Providing and fixing of smoke seal insulation 2- hour fire resistant period (Integrity 120 min and Insulation 120 min ), side rise CWFS -120, insulation thickness 120 mm minimum top to bottom with factory applied impervious foil face, density minimum 80kg/m3, 10% compression at site as per manufacturer recommendation and tested standards/ make. CWFS-120 enclosed with zinc coated GI clips configured as per fire stop manufacturer’s requirements except as noted herein. Impaling clips shall be fastened to floor slab. joints between strips has to be sealed properly with Class O Aluminium fire rated tape. 1.5mm thick G.I. sheet continuous fix on R.C.C.slab and transom over insulation. ( Smoke seal system warranty minimum should be 10 Years)
Extra Over A.1-Top hung openable-BarcodeUnitized Glazing- Design, engineering, supply and installation of top hung openable windows panels in the integrated unitized curtain wall system constitute of Aluminium extruded section to withstand the designed wind pressure. Aluminium outer frame shall be fixed on mullion and transom (periphery of the opening) with screws. Provide weather silicone both side periphery of outer frame. DGU Glass shall be glazed on Aluminium shutter frame with structural silicone, double adhesive tape etc. complete as per tender drawing/ system requirement. Openable shutter frame fixed on Aluminium outer frame with Friction stay, Limiting arm, de-attachable handle, 6 point locking system etc. as per system supplier approved make. The quote includes openable Aluminium frame sections, screws, friction stay, Limiting arm, de-attachable handle with 6 point locking system, Polyamide strips complete as per tender drawing and site requirement. Double adhesive tape, structural silicone and glass cost paid in above item.
Extra Over A.1-Side hung openable Size-1556mm x 1700mm- BarcodeUnitized Glazing- Design, engineering, supply and installation of top hung openable windows panels in the integrated unitized curtain wall system constitute of Aluminium extruded section to withstand the designed wind pressure. Aluminium outer frame shall be fixed on mullion and transom (periphery of the opening) with screws. Provide weather silicone both side periphery of outer frame. DGU Glass shall be glazed on Aluminium shutter frame with structural silicone, double adhesive tape etc. complete as per tender drawing/ system requirement. Openable shutter frame fixed on Aluminium outer frame with Friction stay, Limiting arm, de-attachable handle, 6 point locking system etc. as per system supplier approved make. The quote includes openable Aluminium frame sections, screws, friction stay, Limiting arm, de-attachable handle with 6 point locking system, Polyamide strips complete as per tender drawing and site requirement. Double adhesive tape, structural silicone and glass cost paid in above item.
GRC Cladding: Design, Supply, fabricate and installation of GRC cladding system constitute of 2.0mm thick powder coated Aluminium sheet (Aluminium alloy 3000 series) shade as per approval. Aluminium solid sheet tray with Aluminium stiffener as per structural requirement to be Fixed on Aluminium frame (Vertical and horizontal) with Aluminium cleat, screws, rivet etc. Aluminium frame fixed on R.C.C. with M.S. H.D.G. bracket, S.S. 316 grade nut bolt with washer, anchor fastener, packing shim complete with all necessary hardware as shown in tender drawings . Provide exterior sealant non staining with dowSil/GE with all approved standard accessories and hardware. No bending marks, shear marks allowed on the sheet panel edges or surface after sheet bending process. The contractor must design the system as per the prevalent site conditions and building elevation profiles. The system shall be designed to withstand a wind pressure not less than 3.1 Kpa. All exposed Aluminium profiles shall be Super durable Powder coating in 60 micron +/- 5 micron as per approved shade. Non-exposed Aluminium shall be chromotized. Aluminium extrusions thickness shall not less than 2 mm & Shall be confirming to Alloy 6063-T6. All screws, Nuts, Bolts, washers and anchors shall be only stainless steel of 316 grade. Anchors to be Hilti /Fischer Make. The quote should includes Aluminium solid sheet, sheet bending, Aluminium frame, Aluminium stiffener, bracket, anchor, nut-bolt, screws, sealant, packing shim, setting block. The Contractor's quote shall be based on finished installed product as per architect design, facade Tender drawings, structural requirement and at any stage, shall not charge extra for Aluminium profile wall thickness and size dimensions.
MS Fabrication for GRC Cladding Providing MS in required sections fixed with insert plates or angle cleats, beams, channels for supporting the utilities, ladders and platforms with railings and the like as per detailed designs & drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/ bolted/ welded connections and including priming coat of approved steel primer & painting, at all levels complete as directed by Engineer-in-charge.
Aluminium Seamless Railing System Design, Fabricate, Supply, Installation and handover of seamless glass railing System constitute of aluminium powder coated seamless railing system fixed on R.C.C. up stand with anchor fastener ( anchor C/C distance not more than 350mm) packing shim etc. 21.52mm (10mm FT+1.52mm SGP+10mm FT) sentry laminated glass fixed in to aluminium railing system with EPDM gasket separator , Hard PVC inclined packing shim, setting block, weather silicon etc. Complete as shown in the tender drawing. 30x30x2mm thick aluminium channel fixed on the top of glass with packing shim, silicon. The contractor must design the system as per the prevalent site conditions and building elevation profiles. The system shall be designed to withstand a wind pressure not less than 1.71kpa. No extra claims shall be entertained at any stage for U-channel wall thickness and size dimensions and glass thickness. The Contractor must quote rates accordingly. All hardwares shall be of approved make.
17.52mm (8mm FT+1.52mm SGP+8mm FT) Thick Sentry Laminated Glass for Aluminium Seamless Railing System
Spider Canopy System Design, Supply, Fabricate and Installation of spider canopy system consist of 17.52mm sentry laminated glass as shown in tender drawings to be Fixed on M.S. H.D.G. structure support cantilever with S.S. threaded stud, spider fittings, routel, nylon bush, bolt etc. complete with all necessary hardware as per requirement. Provide weather sealant of approved make in all grooves .The joint between glass panel 8-10mm. MS cantilever support structure fixed on glazing system with m.s. bracket, nut-bolt, MS tie rod support fixed on glazing system. The contractor must design the system as per the prevalent site conditions and building elevation profiles. The system shall be designed to withstand a wind pressure not less than 1.26Kpa. All Nuts, Bolts, washers , Spider fitting shall be only stainless steel of 316 grade. The quote should inclusive of M.S. Structure, Anchor fastener, S.S. stud, S.S. spider fitting, Routel, clear weather silicone etc. No extra claim shall be entertained at any stage.
17.52mm (8mm FT+1.52mm SGP+8mm FT) Thick Sentry Laminated Glass for Spider canopy system
MS Fabrication for Spider canopy system Providing MS in required sections fixed with insert plates or angle cleats, beams, channels for supporting the utilities, ladders and platforms with railings and the like as per detailed designs & drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/ bolted/ welded connections and including priming coat of approved steel primer & painting, at all levels complete as directed by Engineer-in-charge.
Tile Cladding system Design, Supply, fabricate and installation of Tile cladding closed groove system constitute of 5mm thick Tile exterior grade (shade as approval) as shown in tender drawings to be glazed on aluminium frame with 6mm thick Double adhesive tape, Structural silicone, note that silicone compatibility is to be checked with the specified supplier, if required appropriate Primer/Sealer to be used prior to silicone application and structural adequacy complete as per tender drawing & site requirement. Aluminium T- frame fixed on m.s. h.d.g./RCC Structure with M.S. H.D.G. bracket, nut bolt, anchor fastener, packing shim etc. complete with all necessary hardware. 20x12x2mm aluminium channel powder coaded ( Golden shade) fixed over tile cladding grooves as shown in the tender drawing. 0.8mm GI sheet fixed on mullion and tube with screws @ back side of C- Feature Tile cladding. 48kg/m3 glass wool insulation enclosed in 4mm thick ACP Sheet with adhesive, GI clip and fixed on mullion, tubes with screws at visibible location back side of C- Feature Tile cladding ( ACP sheet shall be inside ). Provide exterior sealant in all grooves and periM with dowSil/GE make with all approved standard accessories and hardware. The system shall be designed to withstand a wind pressure not less than 1.71Kpa. All exposed Aluminium profiles shall be Super durable Powder coating in 60 micron +/- 5 micron as per approved shade. Non-exposed Aluminium shall be chromotized. Aluminium extrusions thickness shall not less than 2 mm & Shall be confirming to Alloy 6063-T6. All screws shall be only stainless steel of 316 grade. The quote should includes Tile, Aluminium frame, GI sheet, insulation, ACP sheet, MS structure, bolt, Anchor fastener, packing shim, setting block. The Contractor's quote shall be based on finished installed product as per architect design, facade Tender drawings, structural requirement and at any stage, shall not charge extra for Aluminium profile wall thickness and size dimensions.
Tile Sheet for Tile Cladding system Design, Supply, fabricate and installation of Tile cladding closed groove system constitute of 5mm thick Tile exterior grade (shade as approval) as shown in tender drawings to be glazed on aluminium frame with 6mm thick Double adhesive tape, Structural silicone, note that silicone compatibility is to be checked with the specified supplier, if required appropriate Primer/Sealer to be used prior to silicone application and structural adequacy complete as per tender drawing & site requirement. Aluminium T- frame fixed on m.s. h.d.g./RCC Structure with M.S. H.D.G. bracket, nut bolt, anchor fastener, packing shim etc. complete with all necessary hardware. 20x12x2mm aluminium channel powder coaded ( Golden shade) fixed over tile cladding grooves as shown in the tender drawing. 0.8mm GI sheet fixed on mullion and tube with screws @ back side of C- Feature Tile cladding. 48kg/m3 glass wool insulation enclosed in 4mm thick ACP Sheet with adhesive, GI clip and fixed on mullion, tubes with screws at visibible location back side of C- Feature Tile cladding ( ACP sheet shall be inside ). Provide exterior sealant in all grooves and periM with dowSil/GE make with all approved standard accessories and hardware. The system shall be designed to withstand a wind pressure not less than 1.71Kpa. All exposed Aluminium profiles shall be Super durable Powder coating in 60 micron +/- 5 micron as per approved shade. Non-exposed Aluminium shall be chromotized. Aluminium extrusions thickness shall not less than 2 mm & Shall be confirming to Alloy 6063-T6. All screws shall be only stainless steel of 316 grade. The quote should includes Tile, Aluminium frame, GI sheet, insulation, ACP sheet, MS structure, bolt, Anchor fastener, packing shim, setting block. The Contractor's quote shall be based on finished installed product as per architect design, facade Tender drawings, structural requirement and at any stage, shall not charge extra for Aluminium profile wall thickness and size dimensions.
MS Fabrication for Tile Cladding include Providing MS in required sections fixed with insert plates or angle cleats, beams, channels for supporting the utilities, ladders and platforms with railings and the like as per detailed designs & drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/ bolted/ welded connections and including priming coat of approved steel primer & painting, at all levels complete as directed by Engineer-in-charge.
Providing and fixing Double Leaf Patch fitted glass door of 2400x2400 of approved make conforming to IS: 733 and IS: 1285 having polyester powder coating (minimum thickness of polyester powder coating 50 micron), fixing with SS 304 dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket, SS & Aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, pressure cleat, crimping angle, Shutter made from 12mm thick clear toughened glass panes with glazing clip, EPDM rubber/ neoprene gasket etc complete including all necessary hardware like Floor spring, Door closer, Hinges, Mortise Dead Lock, Handle, Tower bolt, Flush tower bolt, Door Buffer, Door seal, etc. all complete as per detailed specifications and as directed by Engineer-in-charge.
Providing and fixing Single Leaf Patch fitted glass door-1500x3000 of approved make conforming to IS: 733 and IS: 1285 having polyester powder coating (minimum thickness of polyester powder coating 50 micron), fixing with SS 304 dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket, SS & Aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, pressure cleat, crimping angle, Shutter made from 12mm thick clear toughened glass panes with glazing clip, EPDM rubber/ neoprene gasket etc complete including all necessary hardware like Floor spring, Door closer, Hinges, Mortise Dead Lock, Handle, Tower bolt, Flush tower bolt, Door Buffer, Door seal, etc. all complete as per detailed specifications and as directed by Engineer-in-charge.
SITC OF PHE 810TR,FLOW 276M3/HR,PN 16 Design, Supply, Lifting & Shifting at actual proposed location on site, Installation, Testing, Commissioning and Field Performance Validation of Plate type Heat Exchanger Systems (4 working+ 1 stand by) Heat Exchanged capacity: Hot side Cold side Hot Water Chilled Water Heat Exchange 810 TR VOLUME FLOW 276 m3/Hr 276 m3/Hr Temperature Inlet 15.0 +/-0.5°C 5.00+/-0.5°C Temperature Outlet 6.0 +/- 0.5 °C 14.00+/-0.5°C Max. Pressure Drop 0.6 Bar Max. Working Pressure 16 Bar PHE to be AHRI 400 Certified and ASME Stamped
SITC OF 1000 LTR EXPN TANK WITH ACC. Supply, Installation, Testing & Commissioning of Precharged steel closed expansion tank with replaceable heavy duty butyl rubber bladder, mounting stand with all necessary system connection & charging valve connection to facilitate on site charging. Tank to meet ASME Boiler & pressure vessel code all valve mounting etc. System to be complete with pressurization unit and accessories like Pumps, pressure reducing valve, auto air purge, centrifugal air separator etc.
SITC OF 5LPH/6M WC AUTO CHEM DOS SYST Design, Supply, Lifting & Shifting at actual proposed location on site, Installation, Testing, Commissioning and Field Performance Validation of Automatic Chemical Dosing System including all accessories like pumps, tank, injector, tubing etc. Capacity : 5 LPH / 6 M WC
SITC OF HRU, EX-15000C FM & FA-19500C FM Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Floor Mounted Heat Recovery Units. Supply, Installation, Testing & Commissioning of Heat Recovery unit comprising of higher enthalapy efficiency, Fresh Air Section with Fan with Prefilters, Exhaust Air Section with Fan with best efficiency Plug Fan with VFD driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IPSS / 4P TEFC Fan Motor, fire resistant flexible fan outlet connection, The AHU shall comprise filter section with Air filtering media (MERV 13 atleast) with 10 micron pre filter,Damper at all inlet outlet side as specified and integrated / controlled with 65 mm static pressure at exhaust & 50 mm static pressure at fresh air side. Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Damper, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual Status, fire status controlling, contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested. Heat Recovery Unit - 15000 CFM Exhaust and 19500 CFM Fresh Air
HRU2, EX-15000C FM & FA-19500C PM Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Floor Mounted Heat Recovery Units.Supply, Installation, Testing & Commissioning of Heat Recovery unit comprising of higher enthalapy efficiency, Fresh Air Section with Fan with Prefilters, Exhaust Air Section with Fan with best efficiency Plug Fan with VFD driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IPSS / 4P TEFC Fan Motor, fire resistant flexible fan outlet connection, The AHU shall comprise filter section with Air filtering media (MERV 13 atleast) with 10 micron pre filter,Damper at all inlet outlet side as specified and integrated / controlled with 65 mm static pressure at exhaust & 50 mm static pressure at fresh air side. Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Damper, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual Status, fire status controlling, contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested. Heat Recovery Unit 2 - 15000 CFM Exhaust and 19500 CFM Fresh Air
SITC OF 4 WAY CASSETTE UNIT 400CFM Design, Supply, Lifting & Shifting at actual proposed location of site, lnstallation, Testing, Commissioning and Field Performance Validation of Ceiling suspended Chilled Water Cassettes, 4 way flow type Fan Coil Units with energy saving Single Phase BLOC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al fins and Copper Chilled Water Cooling Coil section with minimum 2 Row and minimum 13 FPI, in-built condensate drain pump, pre- assembled valve station with set of brass ball valve with “Y” strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way solenoid control valve of minimum PN25 rating with P/T plugs and minimum IP54 thermo electric actuator fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping with brass ball valve; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. Unit shall be supplied with BMS compatible Digital Group Controller, necessary Networking Adapters and Gateway with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 M cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 1.0TR / 400 CFM
SITC OF 4 WAY CASSETTE UNIT 600CFM Design, Supply, Lifting & Shifting at actual proposed location of site, lnstallation, Testing, Commissioning and Field Performance Validation of Ceiling suspended Chilled Water Cassettes, 4 way flow type Fan Coil Units with energy saving Single Phase BLOC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al fins and Copper Chilled Water Cooling Coil section with minimum 2 Row and minimum 13 FPI, in-built condensate drain pump, pre- assembled valve station with set of brass ball valve with “Y” strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way solenoid control valve of minimum PN25 rating with P/T plugs and minimum IP54 thermo electric actuator fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping with brass ball valve; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. Unit shall be supplied with BMS compatible Digital Group Controller, necessary Networking Adapters and Gateway with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 M cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 1.5TR / 600 CFM
SITC OF 4 WAY CASSETTE UNIT 800CFM Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling suspended Chilled Water Cassettes, 4 way flow type Fan Coi1 Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al fins and Copper Chilled Water Cooling Coil section with minimum 2 Row and minimum 13 FPI, in-built condensate drain pump, pre- assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way solenoid control valve of minimum PN25 rating with P/T plugs and minimum IP54 thermo electric actuator fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping with brass ball valve; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. Unit shall be supplied with BMS compatible Digital Group Controller, necessary Networking Adapters and Gateway with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 M cable from Controller to FCU as required.The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 2.0TR / 800 CFM
SITC OF 4 WAY CASSETTE UNIT 1000CFM Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling suspended Chilled Water Cassettes, 4 way flow type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al fins and Copper Chilled Water Cooling Coil section with minimum 2 Row and minimum 13 FPI, in-built condensate drain pump, pre- assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way solenoid control valve of minimum PN25 rating with P/T plugs and minimum IP54 thermo electric actuator fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping with brass ball valve; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. Unit shall be supplied with BMS compatible Digital Group Controller, necessary Networking Adapters and Gateway with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 M cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer’s factory. 2.5TR / 1000 CFM
SITC OF 4 WAY CASSETTE UNIT 1200CFM Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling suspended Chilled Water Cassettes, 4 way flow type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al fins and Copper Chilled Water Cooling Coil section with minimum 2 Row and minimum 13 FPI, i densate d rain pump, pre-assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way solenoid control valve of minimum PN25 rating with P/T plugs and minimum IP54 thermo electric actuator fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping with brass ball valve; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. Unit shall be supplied with BMS compatible Digital Group Controller, necessary Networking Adapters and Gateway with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 M cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 3.0TR / 1200 CFM
SITC OF 4 WAY CASSETTE UNIT 1400CFM Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling suspended Chilled Water Cassettes, 4 way flow type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al fins and Copper Chilled Water Cooling Coil section with minimum 2 Row and minimum 13 FPI, i densate d rain pump, pre-assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way solenoid control valve of minimum PN25 rating with P/T plugs and minimum IP54 thermo electric actuator fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping with brass ball valve; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. Unit shall be supplied with BMS compatible Digital Group Controller, necessary Networking Adapters and Gateway with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 M cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 3.5TR / 1400 CFM
SITC OF 4 WAY CASSETTE UNIT 1600CFM Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling suspended Chilled Water Cassettes, 4 way flow type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al fins and Copper Chilled Water Cooling Coil section with minimum 2 Row and minimum 13 FPI, i densate d rain pump, pre-assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way solenoid control valve of minimum PN25 rating with P/T plugs and minimum IP54 thermo electric actuator fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping with brass ball valve; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. Unit shall be supplied with BMS compatible Digital Group Controller, necessary Networking Adapters and Gateway with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 M cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 4.0 TR / 1600 CFM
SITC DOUBLE SKIN FAHU Supplying, installing, testing and commissioning of factory built double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.6 mm outside layer and 0.6mm inside layer with polyurethene foam (PUF) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan, 6 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), filter sections with 50 mm thick washable synthetic type air pre-filters having efficiency 90% down to 10 micron with MERV 13 secondary filter, belt with TEFC drive motor (Eff-1 ) suitable for 415+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with VFD & VFD Panel, starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, fire status controlling Temperature Indicator availability on Panel with BMS compatibility; Starter panel shall be minimum 14G MS powder coated, inside light and duly internally wired and tested. Followings are capacities. 32TR/16000CFM 80 mm WC Static Pressure.
SITC DOUBLE SKIN FAHU Supplying, installing, testing and commissioning of factory built double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.6 mm outside layer and 0.6mm inside layer with polyurethene foam (PUF) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan, 6 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), filter sections with 50 mm thick washable synthetic type air pre-filters having efficiency 90% down to 10 micron with MERV 13 secondary filter, belt with TEFC drive motor (Eff-1 ) suitable for 415+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with VFD & VFD Panel, starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, fire status controlling Temperature Indicator availability on Panel with BMS compatibility; Starter panel shall be minimum 14G MS powder coated, inside light and duly internally wired and tested. Followings are capacities. 25TR/12000CFM 80 mm WC Static Pressure.
SITC DOUBLE SKIN FAHU Supplying, installing, testing and commissioning of factory built double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.6 mm outside layer and 0.6mm inside layer with polyurethene foam (PUF) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan, 6 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), filter sections with 50 mm thick washable synthetic type air pre-filters having efficiency 90% down to 10 micron with MERV 13 secondary filter, belt with TEFC drive motor (Eff-1 ) suitable for 415+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with VFD & VFD Panel, starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, fire status controlling Temperature Indicator availability on Panel with BMS compatibility; Starter panel shall be minimum 14G MS powder coated, inside light and duly internally wired and tested. Followings are capacities. 20TR/10000CFM 80 mm WC Static Pressure.
SITC DOUBLE SKIN FAHU Supplying, installing, testing and commissioning of factory built double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.6 mm outside layer and 0.6mm inside layer with polyurethene foam (PUF) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan, 6 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), filter sections with 50 mm thick washable synthetic type air pre-filters having efficiency 90% down to 10 micron with MERV 13 secondary filter, belt with TEFC drive motor (Eff-1 ) suitable for 415+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with VFD & VFD Panel, starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, fire status controlling Temperature Indicator availability on Panel with BMS compatibility; Starter panel shall be minimum 14G MS powder coated, inside light and duly internally wired and tested. Followings are capacities. 17TR/7500CFM 80 mm WC Static Pressure.
SITC DOUBLE SKIN AHU 8.11TR/4200CFM Supplying, installing, testing and commissioning of factory built Ceiling Suspended double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.6 mm outside layer and 0.6mm inside layer with polyurethene foam (PUF) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan, 6 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), filter sections with 50 mm thick washable synthetic type air pre-filters having efficiency 90% down to 10 micron with MERV 13 secondary filter, belt with TEFC drive motor (Eff-1 ) suitable for 415+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with VFD & VFD Panel, starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, fire status controlling Temperature Indicator availability on Panel with BMS compatibility; Starter panel shall be minimum 14G MS powder coated, inside light and duly internally wired and tested. Followings are capacities. 8.11 TR / 4200 CFM 40 mm WC Static Pressure For Lobby & Lift Lobby at 2nd Basement
SITC DOUBLE SKIN AHU 5.5TR/2200CFM Supplying, installing, testing and commissioning of factory built Ceiling Suspended double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.6 mm outside layer and 0.6mm inside layer with polyurethene foam (PUF) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan, 6 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), filter sections with 50 mm thick washable synthetic type air pre-filters having efficiency 90% down to 10 micron with MERV 13 secondary filter, belt with TEFC drive motor (Eff-1 ) suitable for 415+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with VFD & VFD Panel, starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, fire status controlling Temperature Indicator availability on Panel with BMS compatibility; Starter panel shall be minimum 14G MS powder coated, inside light and duly internally wired and tested. Followings are capacities. 5.5 TR / 2200 CFM 40 mm WC Static Pressure.
SITC DOUBLE SKIN AHU 5.0TR/2000CFM Supplying, installing, testing and commissioning of factory built Ceiling Suspended double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.6 mm outside layer and 0.6mm inside layer with polyurethene foam (PUF) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan, 6 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), filter sections with 50 mm thick washable synthetic type air pre-filters having efficiency 90% down to 10 micron with MERV 13 secondary filter, belt with TEFC drive motor (Eff-1 ) suitable for 415+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with VFD & VFD Panel, starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, fire status controlling Temperature Indicator availability on Panel with BMS compatibility; Starter panel shall be minimum 14G MS powder coated, inside light and duly internally wired and tested. Followings are capacities. 5.0 TR / 2000 CFM 40 mm WC Static Pressure.
SITC DOUBLE SKIN AHU 4.26TR/2200CFM Supplying, installing, testing and commissioning of factory built Ceiling Suspended double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.6 mm outside layer and 0.6mm inside layer with polyurethene foam (PUF) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan, 6 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), filter sections with 50 mm thick washable synthetic type air pre-filters having efficiency 90% down to 10 micron with MERV 13 secondary filter, belt with TEFC drive motor (Eff-1 ) suitable for 41S+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with VFD & VFD Panel, starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, fire status controlling Temperature Indicator availability on Panel with BMS compatibility; Starter panel shall be minimum 14G MS powder coated, inside light and duly internally wired and tested. Followings are capacities 4.26TRR 2200 CFM / 40 mm WC Static Pressure For Lobby & Lift Lobby at 1st Basement
SITC DOUBLE SKIN AHU 3.50TR/2100CFM Supplying, installing, testing and commissioning of factory built Ceiling Suspended double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.6 mm outside layer and 0.6mm inside layer with polyurethene foam (PU F) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan, 6 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), filter sections with 50 mm thick washable synthetic type air pre-filters having efficiency 90% down to 10 micron with MERV 13 secondary filter, belt with TEFC drive motor (Eff-1 ) suitable for 415+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with VPD & VFD Panel, starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, fire status controlling Temperature Indicator availability on Panel with BMS compatibility; Starter panel shall be minimum 14G MS powder coated, inside light and duly internally wired and tested. Followings are capacities 3.50 TR / 2100 CFM / 40 mm WC Static Pressure.
SITC DOUBLE SKIN AHU 3.00TR/1200CFM Supplying, installing, testing and commissioning of factory built Ceiling Suspended double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.6 mm outside layer and 0.6mm inside layer with polyurethene foam (PU F) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan, 6 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), filter sections with 50 mm thick washable synthetic type air pre-filters having efficiency 90% down to 10 micron with MERV 13 secondary filter, belt with TEFC drive motor (Eff-1 ) suitable for 415+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with VPD & VFD Panel, starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, fire status controlling Temperature Indicator availability on Panel with BMS compatibility; Starter panel shall be minimum 14G MS powder coated, inside light and duly internally wired and tested. Followings are capacities 3.0 TR / 1200 CFM / 40 mm WC Static Pressure.
SITC DOUBLE SKIN AHU 2.33TR/1400CFM Supplying, instailing, testing and commissioning of factory built Ceiling Suspended double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.6 mm outside layer and 0.6mm inside layer with polyurethene foam (PUF) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan, 6 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.Smm), filter sections with 50 mm thick washable synthetic type air pre-filters having efficiency 90% down to 10 micron with MERV 13 secondary filter, belt with TEFC drive motor (Eff-1 ) suitable for 41S+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with VFD & VFD Panel, starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, fire status controlling Temperature Indicator availability on Panel with BMS compatibility; Starter panel shall be minimum 14G MS powder coated, inside light and duly internally wired and tested. Followings are capacities 2.33 TR / 1400 CFM / 40 mm WC Static Pressure For UPS Room at 1st Basement
SITC DOUBLE SKIN AHU 4.29TR/2000CFM Supplying, installing, testing and commissioning of factory built Ceiling Suspended double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.6 mm outside layer and 0.6mm inside layer with polyurethene foam (PUF) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan, 6 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), filter sections with 50 mm thick washable synthetic type air pre-filters having efficiency 90% down to 10 micron with MERV 13 secondary filter, belt with TEFC drive motor (Eff-1 ) suitable for 415+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with VFD & VFD Panel, starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, fire status controlling Temperature Indicator availability on Panel with BMS compatibility; Starter panel shall be minimum 14G MS powder coated, inside light and duly internally wired and tested. Followings are capacities 4.29 TR / 2000 CFM / 40 mm WC Static Pressure
SITC DOUBLE SKIN AHU 4.4STR/2100CFM Supplying, installing, testing and commissioning of factory built Ceiling Suspended double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.6 mm outside layer and 0.6mm inside layer with polyurethene foam (PUF) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan, 6 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), filter sections with 50 mm thick washable synthetic type air pre-filters having efficiency 90% down to 10 micron with MERV 13 secondary filter, belt with TEFC drive motor (Eff-1 ) suitable for 415+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with VFD & VFD Panel, starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, fire status controlling Temperature Indicator availability on Panel with BMS compatibility; Starter panel shall be minimum 14G MS powder coated, inside light and duly internally wired and tested. Followings are capacities 4.4S TR / 2100 CFM / 40 mm WC Static Pressure
SITC DOUBLE SKIN AHU 3.98TR/1900CFM Supplying, installing, testing and commissioning of factory built Ceiling Suspended double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.6 mm outside layer and 0.6mm inside layer with polyurethene foam (PUF) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan, 6 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), filter sections with S0 mm thick washable synthetic type air pre-filters having efficiency 90% down to 10 micron with MERV 13 secondary filter, belt with TEFC drive motor (Eff-1 ) suitable for 415+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with VFD & VFD Panel, starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Sta supplied with matchingrating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status 0n / Off / Trip, Automanual Status, fire status controlling Temperature Indicator availability on Panel with BMS compatibility; Starter panel shall be minimum 14G MS powder coated, inside light and duly internally wired and tested. followings are capacities 3.98 TR / 1900 CFM / 40 mm WC Static Pressure
SITC DOUBLE SKIN AHU 3.8TR/1800CFM Supplying, installing, testing and commissioning of factory built Ceiling Suspended double skin type air handling units made of 25 mm thick panels consisting of G.l. casing of thickness 0.6 mm outside layer and 0.6mm inside layer with polyurethene foam (PUF) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan, 6 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), filter sections with 50 mm thick washable synthetic type air pre-filters having efficiency 90% down to 10 micron with MERV 13 secondary filter, belt with TEFC drive motor (Eff-1 ) suitable for 415+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with VFD & VFD Panel, starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, fire status controlling Temperature Indicator availability on Panel with BMS compatibility; Starter panel shall be minimum 14G MS powder coated, inside light and duly internally wired and tested. Followings are capacities 3.80 TRJ1800 CFM 40 mm WC Static Pressure For Corridor at 2nd Floor
SITC DOUBLE SKIN AHU 2.7TR/1150CFM Supplying, installing, testing and commissioning of factory built Ceiling Suspended double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.6 mm outside layer and 0.6mm inside layer with polyurethene foam (PUF) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan, 6 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), filter sections with 50 mm thick washable synthetic type air pre-filters having efficiency 90% down to 10 micron with MERV 13 secondary filter, belt with TEFC drive motor (Eff-1 ) suitable for 415+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with VFD & VFD Panel, starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, fire status controlling Temperature Indicator availability on Panel with BMS compatibility; Starter panel shall be minimum 14G MS powder coated, inside light and duly internally wired and tested. followings are capacities 2.70 TR 1150 CFM / 40 mm WC Static Pressure For Lobby & Lift Lobby at 3rd to 2Sth Floor
SITC DOUBLE SKIN AHU 2.6TR/1100CFM Supplying, installing, testing and commissioning of factory built Ceiling Suspended double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.6 mm outside layer and 0.6mm inside layer with polyurethene foam (PUF) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan, 6 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), filter sections with S0 mm thick washable synthetic type air pre-filters having efficiency 90% down to 10 micron with MERV 13 secondary filter, belt with TEFC drive motor (Eff-1 ) suitable for 415+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with VFD & VFD Panel, starter panel, drain connections with d rain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, fire states controlling Temperature Indicator availability on Panel with BMS compatibility; Starter panel shall be minimum 14G MS powder coated, inside light and duly internally wired and tested. Followings are capacities 2.60 TR / 1100 CFM 40 mm WC Static Pressure For Corridor at 3rd to 4th Floor
SITC DOUBLE SKIN AHU 4.23TR/2000CFM Supplying, installing, testing and commissioning of factory built Ceiling Suspended double skin type air handling units made of 2S mm thick panels consisting of G.I. casing of thickness 0.6 mm outside layer and 0.6mm inside layer with polyurethene foam (PUF) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan, 6 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0 filter sections with 50 mm thick washable synthetic type air pre-filtershaving efficiency 90% down to 10 micron with MERV 13 secondary filter, belt with TEFC drive motor (Eff-1 ) suitable for 415+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with VFD & VFD Panel, starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, fire status controlling Temperature Indicator availability on Panel with BMS compatibility; Starter panel shall be minimum 14G MS powder coated, inside light and duly internally wired and tested. Followings are capacities 4.23 TR / 2000 CFM / 40 mm WC Static Pressure For Lobby & Lift Lobby at 26th Floor
SITC DX SPLIT UNIT OF 1.STR Supply, Installation, Testing & Commissioning of Stand by DX type Inverter based Wall Mounted Split Units with indoor units as Hi Gloss all fiber exteriors having galvanized steel back plate. The outdoor unit shall be precharged Refrigerant R 410a and accessories such as refrigerant shut off valves at compressor and liquid refrigerant outlet. The indoor unit shall be supplied with drain hose, clamp metal, washer fixing plate, sealing pads, screws, clamps, washer for hanging bracket & insulation for fitting, Cordless Remote Controller. The rates shall be without refrigerant piping. The units shall be as per following capacity - 1.5 TR
SITC DX SPLIT UNIT OF 2TR Supply, Installation, Testing & Commissioning of Stand by DX type Inverter based Wall Mounted Split Units with Indoor units as Hi Gloss all fiber exteriors having galvanized steel back plate. The outdoor unit shall be precharged Refrigerant R 410a and accessories such as refrigerant shut off valves at compressor and liquid refrigerant outlet. The indoor unit shall be supplied with drain hose, clamp metal, washer fixing plate, sealing pads, screws, clamps, washer for hanging bracket & insulation for fitting, Cordless Remote Controller. The rates shall be without refrigerant piping. The units shall be as per following capacity - 2.0 TR
SITC COPR PIPE FOR 1.5TR WITH NR INSU Supply, Installation, Testing & Commissioning of Refrigerant copper piping duly insulated with required thickness closed cell electrometric Nitrile Rubber covered interconnecting indoor & outdoor unit. Metallic foil membrane shall be applied to provide resistance against breakdown due to UV radiation for exposed portion of the Rubber Insulation. The refrigerant piping shall be laid with proper supports as required on prepared Tray. Rates shall be inclusive of the same. Complete Clamping and saddling of cabling work and refrigerant piping, covered with P V C conduiting. Suction & Descharge circuit shall be considered as a single circuit to measure the length. Sinle length of circuit shall be considered for each unit to measure the length. 1.5 TR
SITC COPR PIPE FOR 2TR WITH NR INSU Supply, Installation, Testing & Commissioning of Refrigerant copper piping duly insulated with required thickness closed cell electrometric Nitrile Rubber covered interconnecting indoor & outdoor unit. Metallic foil membrane shall be applied to provide resistance against breakdown due to UV radiation for exposed portion of the Rubber insulation. The refrigerant piping shall be laid with proper supports as required on prepared Tray. Rates shall be inclusive of the same. Complete Clamping and saddling of cabling work and refrigerant piping, covered with P V C conduiting. Suction & Descharge circuit shall be considered as a single circuit to measure the length. Sinle length of circuit shall be considered for each unit to measure the length. 2.0 TR
SITC INLINE EX FAN, 300CFM 15M M SP Ventilation Supply, Installation, Testing & Commissioning of ceiling suspended type Inline Exhaust Air Fan, as per specifications of 300 CFM / 15mm Static Pressure
SITC INLINE EX FAN, 400CFM 15MM SP Supply, Installation, Testing & Commissioning of ceiling suspended type Inline Exhaust Air Fan, as per specifications of 400 CFM / 15mm Static Pressure
SITC PROPLR EX FAN,1500CFM 10MM SP Supply, Installation, Testing & Commissioning of Propeller type Exhaust Air Fan, as per specifications. 1500 CFM / 10mm Static Pressure
SITC PROPLR EX FAN,900CFM 10MM SP Supply, Installation, Testing & Commissioning of Propeller type Exhaust Air Fan, as per specifications 900 CFM / 10mm Static Pressure
SITC PROPLR EX FAN,1400CFM 10MM SP Supply, Installation, Testing & Commissioning of Propeller type Exhaust Air Fan, as per specifications 1400 CFM 10mm Static Pressure
SITC PROPLR EK FAN,1100CFM 10MM SP Supply, Installation, Testing & Commissioning or Propeller type Exhaust Air Fan, as per specifications 1100 CFM / 10mm Static Pressure
2 PROPLR EX PAN,1400CFM 10MM SP1400 CFM / 10mm Static Pressure
TUBE AXL FANS,36000CFM 20MM SP Supply, installation, testing and commissioning of Tube Axial fans complete with Hot dipped Galvanised Steel Casing, adjustable pitch die cast aluminium impeller (Hub and blades), motors with VFD & spun flanges on both ends. Casing position shall be as per the job requirement and shall be marked on the fan assembly. Fan inlet & outlet side fire rated canvass connections & non return dampers to be required. All other fan Floor mounting accessories will be provide with the fan. Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual Status, fire status controlling, contacts for remote operation through Operating Panels, BAS compatibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested. 36000 CFM 20mm Static Pressure for Liftwell Pressurization Fan (1 W + 1 S)
TUBE AXL FANS,36000CFM 20MM SP36000 CFM / 20mm Static Pressure for Liftwell Pressurization Fan (1 W + 1 S)
SITC TUBE AXL FANS,9000CFM 20MM SP9000 CFM / 20mm Static Pressure for Liftwell Pressurization Fan (1 W + 1 S)
TUBE AXL FANS,18000CFM 20MM SP18000 CFM / 20mm Static Pressure for Staircase Pressurization Fan (1 W + 1 S)
TUBE AXL FANS,18000C FM 20MM SP18000 CFM / 20mm Static Pressure for Staircase Pressurization Fan (1 W + 1 S)
35000 CFM / 20mm Pressurization Fan Supply, installation, testing and commissioning of Tube Axial fans complete with Hot dipped Galvanised Steel Casing, adjustable pitch die cast aluminium impeller (Hub and blades), motors with VFD & spun flanges on both ends. Casing position shall be as per the job requirement and shall be marked on the fan assembly. Fan inlet & outlet side fire rated canvass connections & non return dampers to be required. All other fan Floor mounting accessories will be provide with the fan. Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual Status, fire status controlling, contacts for remote operation through Operating Panels, BAS compatibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested. A set of 35000 CFM / 20mm Static Pressure for Staircase Pressurization Fan JI W + 1 S) complete set
22000 CFM / 20mm Pressurization Fan Supply, installation, testing and commissioning of Tube Axial fans complete with Hot dipped Galvanised Steel Casing, adjustable pitch die cast aluminium impeller (Hub and blades), motors with VFD & spun flanges on both ends. Casing position shall be as per the job requirement and shall be marked on the fan assembly. Fan inlet & outlet side fire rated canvass connections & non return dampers to be required. All other fan Floor mounting accessories will be provide with the fan. Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual Status, fire status controlling, contacts for remote operation through Operating Panels, BAS compatibility; Starter panel shall be minimum 14G MS powder coated tvith ventilation fan, inside light and duly internally wired and tested. A set of 35000 CFM / 20mm Static Pressure for Staircase Pressurization Fan (1 W + 1 S) complete set
SITC TUBE AXL FANS,14000CFM 20MM SP14000 CFM / 20mm Static Pressure - For Lobby fresh air intake during fire mode.(1 W + 1 S)
SiTC EM TUBE AXL FANS,14000CFM 20M M SP Smoke Evacuation System (On emergency mode only) Supply, installation, testing and commissioning of Tube Axial fans complete with Hot dipped Galvanised Steel Casing, adjustable pitch die cast aluminium impeller (Hub and blades), motors with VFD & spun flanges on both ends. Casing position shall be as per the job requirement and shall be marked on the fan assembly. The Fan assembly along with motors should be tested for Temperature range: 300 °C / 2 Hours for Smoke Evacuation as per EN 12101-3. Fan inlet & outlet side fire rated canvass connections & non return dampers to be required. All other fan Floor mounting accessories will be provide with the fan. Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual Status, fire status controlling, contacts for remote operation through Operating Panels, BAS compatibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested. Capacity CFM 14000 @ 15 mm Static - For Lobby Smoke Evacuation.(1 W + 1 S)
SITC 350M M PI PE,ACC. AND NR I NSU+GC Supplying, laying / fixing, testing and commissioning of following nominal sizes of chilled water piping as per IS 3589 (excluding valves, strainers, gauges etc.) insulated with 38mm thk Antimicrobial Closed Cell Nitrile Rubber with Glass Cloth as per detail specifications complete with all fittings and accessories such as Flanges (as per ASME 16.S), Elbows, tees, reducers (as per ASME 16.9), Nut Bolts, Puf block Supports, M.S. Angle & Rod Supporting clevis hangers with vibration isolators etc. for: 350mm dia of min. 6.35mm thk
SITC 300M M PI PE,ACC. AND NR I NSU+GC Supplying, laying / fixing, testing and commissioning of following nominal sizes of chilled water piping as per IS 3589 (excluding valves, strainers, gauges etc.) insulated with 38mm thk Antimicrobial Closed Cell Nitrile Rubber with Glass Cloth as per detail specifications complete with all fittings and accessories such as Flanges (as per ASME 16.5), Elbows, tees, reducers (as per ASME 16.9), Nut Bolts, Puf block Supports, M.S. Angle & Rod Supporting clevis hangers with vibration isolators etc. for: 300mm dia of min. 6.35mm thk
SITC 250MM PIPE,ACC. AND NR I NSU+GC Supplying, laying / fixing, testing and commissioning of following nominal sizes of chilled water piping as per IS 3589 (excluding valves, strainers, gauges etc.) insulated with 32mm thk Antimicrobial Closed Cell Nitrile Rubber with Glass Cloth as per detail specifications complete with all fittings and accessories such as Flanges (as per ASME 16.5), Elbows, tees, reducers (as per ASME 16.9), Nut Bolts, Puf block Supports, M.S. Angle & Rod Supporting clevis hangers with vibration isolators etc. for: 250mm dia of min. 6.35mm thk
SITC 200MM PIPE,ACC. AND NR I NSU+GC Supplying, laying / fixing, testing and commissioning of following nominal sizes of chilled water piping as per lS 3589 (excluding valves, strainers, gauges etc.) insulated with 32mm thk Antimicrobial Closed Cell Nitrile Rubber with Glass Cloth as per detail specifications complete with all fittings and accessories such as Flanges (as per ASME 16.S), Elbows, tees, reducers (as per ASME 16.9), Nut Bolts, Puf block Supports, M.S. Angle & Rod Supporting clevis hangers with vibration isolators etc. for: 200mm dia of min. 6.35mm thk
SITC 150M M PIPE,ACC. AND NR I NSU+GC Supplying, laying / fixing, testing and commissioning of following nominal sizes of chilled water piping of C class heavy grade as per IS 1239 (excluding valves, strainers, gauges etc.) insulated with 32mm thk Antimicrobial Closed Cell Nitrile Rubber with Glass Cloth as per detail specifications complete with all fittings and accessories such as Flanges (as per ASME 16.5), Elbows, tees, reducers (as per ASME 16.9), Nut Bolts, Puf block Supports, M.S. Angle & Rod Supporting clevis hangers with vibration isolators etc. for: l50mm dia
SITC 125 MM P1PE,ACC. AND NR I NSU+GC Supplying, laying / fixing, testing and commissioning of following nominal sizes of chilled water piping of C class heavy grade as per IS 1239 (excluding valves, strainers, gauges etc.) insulated with 32mm thk Antimicrobial Closed Cell Nitrile Rubber with Glass Cloth as per detail specifications complete with all fittings and accessories such as Flanges (as per ASME 16.5), Elbows, tees, reducers (as per ASME 16.9), Nut Bolts, Puf block Supports, M.S. Angle & Rod Supporting clevis hangers with vibration isolators etc. for: l25mm dia
SITC 100MM PIPE,ACC. AND NR I NSU+GC Supplying, laying / fixing, testing and commissioning of following nominal sizes of chilled water piping of C class heavy grade as per IS 1239 (excluding valves, strainers, gauges etc.) insulated with 32mm thk Antimicrobial Closed Cell Nitrile Rubber with Glass Cioth as per detail specifications complete with all fittings and accessories such as Flanges (as per ASME 16.5), Elbows, tees, reducers (as per ASME 16.9), Nut Bolts, Puf block Supports, M.S. Angle & Rod Supporting clevis hangers with vibration isolators etc. for: l00mm dia
SITC 80MM PIPE,ACC. AND NR INSU+GC Supplying, laying / fixing, testing and commissioning of following nominal sizes of chilled water piping of C class heavy grade as per IS 1239 (excluding valves, strainers, gauges etc.) insulated with 32mm thk Antimicrobial Closed Cell Nitrile Rubber with Glass Cloth as per detail specifications complete with all fittings and accessories such as Flanges (as per ASME 16.5), Elbows, tees, reducers (as per ASME 16.9), Nut Bolts, Puf block Supports, M.S. Angle & Rod Supporting clevis hangers with vibration isolators etc. for: 80mm dia
SITC 65MM PIPE,ACC. AND NR INSU+GC Supplying, laying / fixing, testing and commissioning of following nominal sizes of chilled water piping of C class heavy grade as per IS 1239 (excluding valves, strainers, gauges etc.) insulated with 32mm thk Antimicrobial Closed Cell Nitrile Rubber with Glass Cloth as per detail specifications complete with all fittings and accessories such as Flanges (as per ASME 16.5), Elbows, tees, reducers (as per ASME 16.9), Nut Bolts, Puf block Supports, M.S. Angle & Rod Supporting clevis hangers with vibration isolators etc. for: 65mmda
SITC 50MM PIPE,ACC. AND NR INSU+GC Supplying, laying / fixing, testing and commissioning of following nominal sizes of chilled water piping of C class heavy grade as per IS 1239 (excluding valves, strainers, gauges etc.) insulated with 25mm thk Antimicrobial Closed Cell Nitrile Rubber with Glass Cloth as per detail specifications complete with all fittings and accessories such as Flanges (as per ASME 16.5), Elbows, tees, reducers (as per ASME 16.9), Nut Bolts, Puf block Supports, M.S. Angle & Rod Supporting clevis hangers with vibration isolators etc. for:50mm dia
SITC 40MM P1PE,ACC. AND NR INSU+GC Supplying, laying / fixing, testing and commissioning of following nominal sizes of chilled water piping of C class heavy grade as per IS 1239 (excluding valves, strainers, gauges etc.) insulated with 25mm thk Antimicrobial Closed Cell Nitrile Rubber with Glass Cloth as per detail specifications complete with all fittings and accessories such as Flanges (as per ASME 16.5), Elbows, tees, reducers (as per ASME 16.9), Nut Bolts, Puf block Supports, M.S. Angle & Rod Supporting clevis hangers with vibration isolators etc. for: 40mm dia
SITC 32MM PIPE,ACC. AND NR INSU+GC Supplying, laying / fixing, testing and commissioning of following nominal sizes of chilled water piping of C class heavy grade as per lS 1239 (excluding valves, strainers, gauges etc.) insulated with 25mm thk Antimicrobial Closed Cell Nitrile Rubber with Glass Cloth as per detail specifications complete with all fittings and accessories such as Flanges (as per ASME 16.5), Elbows, tees, reducers (as per ASME 16.9), Nut Bolts, Puf block Supports, M.S. Angle & Rod Supporting clevis hangers with vibration isolators etc. for:32mm dia
SITC 25MM PIPE,ACC. AND NR INSU+GC Supplying, laying / fixing, testing and commissioning of following nominal sizes of chilled water piping of C class heavy grade as per IS 1239 (excluding valves, strainers, gauges etc.) insulated with 25mm thk Antimicrobial Closed Cell Nitrile Rubber with Glass Cloth as per detail specifications complete with all fittings and accessories such as Flanges (as per ASME 16.5), Elbows, tees, reducers (as per ASME 16.9), Nut Bolts, Put block Supports, M.S. Angle & Rod Supporting clevis hangers with vibration isolators etc. for: 25mm dia
SITC 19MM PIPE,ACC. AND NR INSU+GC Supplying, laying / rixing, testing and commissioning of following nominal sizes of chilled water piping of C class heavy grade as per lS 1239 (excluding valves, strainers, gauges etc.) insulated with 25mm thk Antimicrobial Closed Cell Nitrile Rubber with Glass Cloth as per detail specifications complete with all fittings and accessories such as Flanges (as per ASME 16.5), Elbows, tees, reducers (as per ASME 16.9), Nut Bolts, Puf block Supports, M.S. Angle & Rod Supporting clevis hangers with vibration isolators etc. for:19mm dia
SITC 300MM BTRFLY VALVE WITH IPSU+GC Supplying, fixing, testing and commissioning orsafer type Butterfly Valve as per lS 13095 with pair of matching flanges (as per ASME 16.5), neoprene gasket, nut bolts and duly insulated with same specification of same size piping as per specification for:300 mm dia.
SITC 25OMM BTRFLY VALVE WITH INSU+GCSupplying, fixing, testing and commissioning of wafer type Butterfly Valve as per lS 1309S with pair of matching flanges (as per ASME I 6.5), neoprene gasket, nut bolts and duly insulated with same specification of same size piping as per specification for: 250mm dia.
SITC 200MM BTRFLY VALVE WITH INSU+GC Supplying, fixing, testing and commissioning of wafer type Butterfly Valve as per IS 13095 with pair of matching flanges [as per ASME 16.5), neoprene gasket, nut bolts and duly insulated with same specification of same size piping as per specification for: 200mm dia.
SITC 80MM BTR FLY VALVE WITH INSU+GC Supplying, fixing, testing and commissioning of wafer type Butterfly Valve as per lS 13095 with pair of matching flanges (as per ASME 16.5), neoprene gasket, nut bolts and duly insulated with same specification of same size piping as per specification for: 80mm dia.
SITC 65MM BTRFLY VALVE WITH INSU+GC Supplying, fixing, testing and commissioning of wafer type Butterfly Valve as per IS 1309S with pair of matching flanges (as per ASME 16.5), neoprene gasket, nut bolts and duly insulated with same specification of same size piping as per specification for: 65mm dia.
SITC 50M M BTRFLY VALVE WITH INSU+GC Supplying, fixing, testing and commissioning of wafer type Butterfly Valve as per IS 13095 with pair of matching flanges (as per ASME 16.5), neoprene gasket, nut bolts and duly insulated with same specification of same size piping as per specification for: SOmm dia.
SITC 40MM BALL VALVE WITH INSU+GC Supplying, fixing, testing and commissioning of SS ball valve with SS body and working parts, flanges, duly insulated with same specification of same size piping as per specification for: 40 mm dia.
SITC 32MM BALL VALVE WITH INSU +GC Su pplying, fixing, testing and commissioning of SS ball valve with SS body and working parts, flanges, duly insulated with same specification of same size piping as per specification for:: 32mm dia.
SITC 25MM BALL VALVE WITH INSU+GC Supplying, fixing, testing and commissioning of SS ball valve with SS body and working parts, flanges, duly insulated with same specification of same size piping as per specification for: 25mm dia.
SITC 19M M BALL VALVE WITH INSU+GC Supplying, fixing, testing and commissioning of SS ball valve with SS body and working parts, flanges, duly insulated with same specification of same size piping as per specification for: 19mm dia.
SITC 300M M BLNCING VALVE WITH INSU+GC Supplying, fixing, testing and commissioning of Manual balancing valve with pair of matching flanges (as per ASME 16.5), neoprene gasket, nut bolts and duly insulated with same specification of same size piping as per specification for: 300 mm dia.
SITC 250M M BLNCING VALVE WITH INSU+GC Supplying, fixing, testing and commissioning of Manual balancing valve with pair of matching flanges (as per ASME 16.5), neoprene gasket, nut bolts and duly insulated with same specification of same size piping as per specification for: 250mm dia.
SITC 200M M BLNCING VALVE WITH INSU+GC Supplying, fixing, testing and commissioning of Manual balancing valve with pair of matching flanges (as per ASME 16.5), neoprene gasket, nut bolts and duly insulated with same specification of same size piping as per specification for: 200mm dia.
SITC 80M M BLNCING VALVE WITH INSU+GC Supplying, fixing, testing and commissioning of Manual balancing valve with pair of matching flanges (as per ASME 16.5), neoprene gasket, nut bolts and duly insulated with same specification of same size piping as per specification for: 80mm dia.
SITC 65MM BLNCING VALVE WiTH INSU+GC Supplying, fixing, testing and commissioning of Manual balancing valve with pair of matching flanges (as per ASME 16.5), neoprene gasket, nut bolts and duly insulated with same specification of same size piping as per specification for: 65mm dia.
SITC 50MM BLNCING VALVE WITH INSU+GC Supplying, fixing, testing and commissioning of Manual balancing valve with pair of matching flanges (as per ASME 16.5), neoprene gasket, nut bolts and duly insulated with same specification of same size piping as per specification for: 50mm dia.
SITC 40MM BLNCING VALVE WITH INSU+GC Supplying, fixing, testing and commissioning of Manual balancing valve with pair of matching flanges (as per ASME 16.5), neoprene gasket, nut bolts and duly insulated with same specification of same size piping as per specification for: 40mm dia.
SITC 32MM BLNCING VALVE WITH INSU+GC Supplying, fixing, testing and commissioning of Manual balancing valve with pair of matching flanges (as per ASME 16.5), neoprene gasket, nut bolts and duly insulated with same specification of same size piping as per specification for: 32mm dia.
SITC 25OMM Y-STRAINER WITH INSU+GC Supplying, fixing, testing and commissioning of CI Y Strainer with pair of matching flanges (as per ASME 16.5), neoprene gasket, nut bolts and duly insulated with same specification of same size piping as per specification for: 250 mm dia.
SITC 32MM Y-STRAINER WITH INSU+GC Supplying, fixing, testing and commissioning of CI Y Strainer with pair of matching flanges (as per ASME 16.5), neoprene gasket, nut bolts and duly insulated with same specification of same size piping as per specification for: 32mm dia.
SITC 25MM Y-STRAINER WITH INSU*GC Supplying, fixing, testing and commissioning of CI Y Strainer with pair of matching flanges (as per ASME 16.5), neoprene gasket, nut bolts and duly insulated with same specification of same size piping as per specification for: 25mm dia.
SITC 19MM Y-STRAINER WITH INSU+GC Supplying, fixing, testing and commissioning of CI Y Strainer with pair of matching flanges (as per ASME 16.S), neoprene gasket, nut bolts and duly insulated with same specification of same siZe piping as per specification for: 19mm dia.
SITC 250M M MOT ON/OFF VALVE ,INSU+GC Supplying, fixing, testing and commissioning of Motorized On/Off Butterfly valve with pair of matching flanges (as per ASME 16.S), neoprene gasket, nut bolts and duly insulated with same specification of same size piping as per specification for: 250 mm dia.
SITC 32MM PIBCV WITH INSU+GC Supplying, fixing, testing and commissioning of 2 Way Pressure Independent Dynamic Balancing cum Control Valve complete with flanges, required accessories and duly insulated with same specification of same size piping as per specification for: 32 mm dia.
SITC 2SMM PIBCV WITH INSU+GC Supplying, fixing, testing and commissioning of 2 Way Pressure Independent Dynamic Balancing cum Control Valve complete with flanges, required accessories and duly insulated with same specification of same size piping as per specification for: 25 mm dia.
SITC 19MM PIBCV WITH INSU+GC Supplying, fixing, testing and commissioning of 2 Way Pressure Independent Dynamic Balancing cum Control Valve complete with flanges, required accessories and duly insulated with same specification of same size piping as per specification for: 19mm dia.
SITC OF 20MM AIR PURGE VALVE Supplying, fixing, testing and commissioning of Automatic Air Purge Valve at AHU chilled water outlet pipe duly insulated with same specification of same size piping as per specification for: 20mm dia.
SITC 250MM NRV WITH NR INSU+GC Supplying, fixing, testing and commissioning of Non Return Valve chilled water pt pe duly insulated with same specification of same size piping as per specification and adequately supported for 250mm dia.
SITC 50MM NRV WITH NR INSU+GC Supplying, fixing, testing and commissioning of Non Return Valve chilled water pipe duly insulated with same specification of same size piping as per specification and adequately supported for S0 mm dia.
SITC 100MM DIAL PG 0-10 KG/CM2 Supply & Installation of dial type Pressure Gauge 100 mm size with SS needle valve and fittings 0-10 kg / cm2 range installed as per P & I Diagram.
SITC 100MM DIAL TG 0-50 DEG C Supply & Installation of dial type Temperature Gauge 100 mm size with SS thermowell / coupling / glycerine or eq. conductive fulid and fittings 0 - 50 °C range installed as per P&l diagram.
SITC BTU MTR 1USGPM-30USG PM WITH INSU Supply, Installation, testing and commisioning of chilled water BTU meters as per given below GPM. BTU meters shall be complete with ultrasonic flow measuring device with pair of matching flanges (as per ASME 16.5/equivalent), neoprene gasket, nut bolts. BTU meters shall provide 0-10V / 4-20mA IO to DDC panel. Flowmetre to be duly insulated with same specification of same size piping. BTU meter shall be compatible with open protocol IBMS system along with RTD with cables for From 1 USGPM to 30 USGPM
SITC BTU MTR 31USGPM-60USGPM WITH INSU Supply, Installation, testing and commisioning of chilled water BTU meters as per given below GPM. BTU meters shall be complete with ultrasonic flow measuring device with pair of matching flanges (as per ASME 16.5/equivalent), neoprene gasket, nut bolts. BTU meters shall provide 0-10V / 4-20mA 10 to DDC panel. Flowmetre to be duly insulated with same specification of same size piping. BTU meter shall be compatible with open protocol IBMS system along with RTD with cables for From 31 USG PM to 60 USGPM
SITC BTU MTR 5000USG PM WITH INSU Supply, Installation, testing and commisioning of chilled water BTU meters as per given below GPM. BTU meters shall be complete with ultrasonic flow measuring device with pair of matching flanges (as per ASME 16.S/equivalent), neoprene gasket, nut bolts. BTU meters shall provide 0-10V / 4-20mA 10 to DDC panel. Flowmetre to be duly insulated with same specification of same size piping. BTU meter shall be compatible with open protocol IBMS system along with RTD with cables for 5000 USGPM
SITC RECT 24G STEEL DUCT Supply, fabrication, installation, testing, balancing and commissioning of factory fabricated Ractangular sheet metal ducts as per “SMACNA” Standards specifications with supports in accordance with the approved shop drawings and as per the specifications 24 Gauge ( Thickness 0.63mm)
SITC RECT 22G STEEL DUCT Supply, fabrication, installation, testing, balancing and commissioning of factory fabricated Ractangular sheet metal ducts as per “SMACNA” Standards specifications with supports in accordance with the approved shop drawings and as per the specifications 22 Gauge (Thickness 0.8mm)
SITC RECT 20G STEEL DUCT Supply, fabrication, installation, testing, balancing and commissioning of factory fabricated Ractangular sheet metal ducts as per “SMACNA” Standards specifications with supports in accordance with the approved shop drawings and as per the specifications 20 Gauge (Thickness 1.0mm)
SITC RECT 18G STEEL DUCT Supply, fabrication, installation, testing, balancing and commissioning of factory fabricated Ractangular sheet metal ducts as per “SMACNA” Standards specifications with supports in accordance with the approved shop drawings and as per the specifications 18 Gauge Th ckness 1.25mm
SITC ROUND 22G STEEL DUCT Supply, fabrication, installation, balancing and commissioning of Round shaped ducts as per “SMACNA” Standards specifications with supports in accordance with the approved shop drawings and as required by the specifications 22 Gauge (Thickness 0.8mm)
SITC AL LINEAR GRILL WITHOUT VCD Supply, Fabrication, installation and testing of Powder Coated Extruded Aluminium Linear Grilles with out VCD of Required Airflow Angles.
SITC AL LINEAR GRILL WITH VCD Supply, Fabrication, installation and testing of Powder Coated Extruded Aluminium Linear Grilles with VCD of Required Airflow Angles.
SITC AL DIFFUSER WITH VCD Supply, Fabrication, installation and testing of Powder coated extruded Aluminium Diffuser with VCD as per specification
SITC AL DIFFUSER WITHOUT VCD Supply, Fabrication, installation and testing of Poweder coated extruded Aluminium Diffuser with out VCD as per specification
SITC GI DUCT DAMPER Supply, fabrication, installation, testing, balancing and commissioning of factory fabricated GI Duct Damper
SITC MOT FA DUCT DAMPER Supplying, installation, testing and commissioning of Motorised Dampers for Fresh Air Duct
SITC FA DAMPER ACTUATO R Supplying, installation, testing and commissioning of Actuators of Motorised Dampers for Fresh Air Duct
SITC FIRE DAMPER Supplying, installation, testing and commissioning of fire dampers, the blades and frame shall be min. 1.6 mm thick GI sheet and factory fitted in a sleeve made out of 1.6 mm thick GS Sheet of min. 400 mm long, as & where required, of required sizes including control wiring. The damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal. CBRI tested as per UL 555 and certified for 90 Minutes fire rating etc. complete as required and aser specifications.
SITC FIRE DAMPER ACTUATOR Supplying, installation, testing and commissioning of Actuators for Fire Dampers
19MM THK NR INSU WITH AL FOIL Supply & Installation of Thermal Insulation of Ractangular / Round ducts (within the building) with Class ’O’ Closed Cell Nitrile Rubber with Aluminum foil as per detail specifications 19 mm THK (For Supply Air Duct)
19MM THK NR INSU WITH AL FOiL Supply & Installation of Thermal Insulation of Ractangular / Round ducts (within the building) with Class 'O’ Closed Cell Nitrile Rubber with Aluminum foil as per detail specifications 13 mm THK (For Return Air Ducts
25MMTHK NT lNSU WITH GC Supply & Installation of Thermal Insulation of Ractangular ducts (Exposed to atmosphere) with Closed Cell elastomeric Nitrile Rubber with company bonded GC sheet as per detail specifications 25 mm THK (For Supply Air Duct)
19MMTHK NT INSU WITH GC Supply & Installation of Thermal Insulation of Ractangular ducts (Exposed to atmosphere) with Closed Cell elastomeric Nitrile Rubber with company bonded GC sheet as per detail specifications 19 mm THK (For Return Air Duct )
15MM THK ACOUSTIC NR INSU Supply & Installation of Duct Acoustic Insulation of Open Cell Nitrile Rubber. It shall be fixed inside of the duct with the help of adhesive as per detail specifications - 15 mm Thick
15MM THK ACOUSTIC NR INSU Acoustic Insulation For AHU Rooms & Plant Room - Supply & Installation of 20mm Thick Open Cell Nitrile Rubber sheet as per detail specifications.
RESIN BONDED INSU SLAB SOM M THK Supply & Installation of Under Deck Insulation material shall be Resin Bonded Insulation Slabs having thickness of 50 mm covered with company bonded aluminum foil as er detail specifications.
SITC 50MM HVY DUTY UPVC PIPE, NR INSU Supply, installation, testing & commissioning of insulated UPVC heavy duty drain pipes from AHLi / Fan Coil units drain pans to nearest floor drain complete withinterconnection, flanges, elbows, tees, nuts etc. The insulation shall be with Factory made Class '0' (FM Approved, UL 94, HB, V-0) Closed Cell Nitrile Rubber Material for thicknesses of 13 mm. Thermal Conductivity of this material is 0.035w/m.k. and having q value * 7000 without any outer covering and including with required pipe supports included in M rates. Drain pipe Insulation with plain Nitrile Rubber sleeve & as per detail specifications 50 mm Dia. (13 mm lpia n sleeve & not self sleeve)
SITC 40MM HVY DUTY UPVC PIPE, NR INSU Supply, installation, testing & commissioning of insulated UPVC heavy duty drain pipes from AHU / Fan Coil units drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts etc. The insulation shall be with Factory made Class '0' (FM Approved, UL 94, HB, V-0) Closed Cell Nitrile Rubber Material for thicknesses of 13 mm. Thermal Conductivity of this material is 0.035w/m.k. and having p value z 7000 without any outer covering and including with M required pipe supports included in M rates. Drain pipe Insulation with plain Nitrile Rubber sleeve & as per detail specifications 40 mm (13 mm plain sleeve & not self sleeve)
SITC 32MM HVY DUTY UPVC PIPE, NR INSU Supply, installation, testing & commissioning of insulated UPVC heavy duty drain pipes from AHU / Fan Coil units drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts etc. The insulation shall be with Factory made Class '0’ (FM Approved, UL 94, HB, V-0) Closed Cell Nitrile Rubber Material for thicknesses of 13 mm. Thermal Conductivity of this material is 0.035w/m.k. and having q value z 7000 without any outer covering and including with required pipe supports included in M rates. Drain pipe Insulation with plain Nitrile Rubber sleeve & as per detail specifications 32 mm (13 mm plain sleeve & not self sleeve)
SITC 25MM HVY DUTY UPVC PIPE, NR l NSU Supply, installation, testing & commissioning of insulated UPVC heavy duty drain pipes from AHU / Fan Coil units drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts etc. The insulation shall be with Factory made Class '0' (FM Approved, UL 94, HB, V-0) Closed Cell N itrile Rubber Material for thicknesses of 13 mm. Thermal Conductivity of this material is 0.03Sw/m.k. and having p value z 7000 without any outer covering and including with M required pipe supports included in M rates. Drain pipe lnsu lation with plain Nitrile Rubber sleeve & as per detail specifications 2S mm (13 mm plain sleeve & not self sleeve)
SITC 19MM HVY DUTY UPVC PIPE,NR INSU Supply, installation, testing & commissioning of insulated UPVC heavy duty drain pipes from AHU / Fan Coil units drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts etc. The insulation shall be with Factory made Class '0' (FM Approved, UL 94, HB, V-0) Closed Cell Nitrile Rubber Material for thicknesses of 13 mm. Thermal Conductivity of this material is 0.035w/m.k. and having p value z 7000 without any outer covering and including with required pipe supports included in M rates. Drain pipe Insulation with plain Nitrile Rubber sleeve & as per detail specifications 19 mm (13 mm plain sleeve & not self sleeve)
SITC of ceiling mounted fire rated Tube Axial Exhaust Air Fan with Motor Supply, installation, testing and commissioning of TUBE Axial fans complete with Hot dipped Galvanised Steel Casing, adjustable pitch die cast aluminium impeller (Hub and blades), motors & spun flanges on both ends. Casing position shall be as per the job requirement and shall be marked on the fan assembly. The Fan assembly along with motors should be tested for Temperature range: 300 °C / 2 Hours for Smoke Evacuation as per EN 12101-3. Jn inlet & outlet side fire ratedcanvass connections & non return dampers tO be required. Supply, installing, testing and commissioning of Tube Axial Fans (for normal mode + Fire mode ) CFM 34000 @ 10 mm (1st Basement)
TUBE AXL EX FANS,34000CFM 10MM SP Car Park Basement Ventilation System SITC of ceiling mounted fire rated Tube Axial Exhaust Air Fan with Motor Supply, installation, testing and commissioning of TUBE Axial fans complete with Hot dipped Galvanised Steel Casing, adjustable pitch die cast aluminium impeller (Hub and blades), motors & spun flanges on both ends. Casing position shall be as per the job requirement and shall be marked on the fan assembly. The Fan assembly along with motors should be tested for Temperature range: 300 °C / 2 Hours for Smoke Evacuation as per EN 12101-3. Fan inlet & outlet side fire rated canvass connections & non return dampers to be required. Supply, installing, testing and commissioning of Tube Axial Fans (for normal mode + Fire mode ) CFM 34000 @ 10 mm f2nd Basement)
B1 TUBE AXL EX FANS, S5000CFM 10MM SP Car Park Basement Ventilation System SITC of ceiling mounted fire rated Tube Axial Exhaust Air Fan with Motor Supply, installation, testing and commissioning of TUBE Axial fans complete with Hot dipped Galvanised Steel Casing, adjustable pitch die cast aluminium impeller (Hub and blades), motors & spun flanges on both ends. Casing position shall be as per the job requirement and shall be marked on the fan assembly. The Fan assembly along with motors should be tested for Temperature range: 300 °C / 2 Hours for Smoke Evacuation as per EN 12101-3. Fan inlet & outlet side fire rated canvass connections & non return dampers to be required. Supply, installing, testing and commissioning of Tube Axial Fans (for normal mode + Fire mode ) CFM S5000 @ 10 mm (1st Basement)
TUBE AXL EX FANS,55000CFM 10MM SP Car Park Basement Ventilation System SITC of ceiling mounted fire rated Tube Axial Exhaust Air Fan with Motor Supply, installation, testing and commissioning of TUBE Axial fans complete with Hot dipped Galvanised Steel Casing, adjustable pitch die cast aluminium impeller (Hub and blades), motors & spun flanges on both ends. Casing position shall be as per the job requirement and shall be marked on the fan assembly. The Fan assembly along with motors should be tested for Temperature range: 300 °C / 2 Hours for Smoke Evacuation as per EN 12101-3. Fan inlet & outlet side fire rated canvass connections & non return dampers to be required. Supply, installing, testing and commissioning of Tube Axial Fans (for normal mode + Fire mode ) CFM S5000 @ 10 mm (2nd Basement)
SITC TUBE AXL FA FANS,17000CFM 10MM SP Supply, installing, testing and commissioning of Tube Axial Fans for Fresh Air Supply, installation, testing and commissioning of Axial fans complete with Hot dipped Galvanised Steel Casing, adjustable pitch die cast aluminium impeller (Hub and blades), motors & spun flanges on both ends. Casing position shall be as per the job requirement and shall be marked on the fan assembly. Fan inlet & outlet side canvass connections with non return dampers to be required. CFM 17000 @ 10 mm [2nd Basement)
SITC OF CO DETECTORS Supply, Installation, Testing & Commissioning of CO Detectors.
CFD ANALYSIS FOR CO SIMULATION Computational Fluid Dynamics (CFD) Analysis for CO Simulation.
SITC OF ELECTRICAL PLC PANEL Supply, installation, testing and commissioning of Electrical cum PLC Panel for 2nd Basement & 3rd Basement with MCB feeders with starters for 15 EA dual speed 3 phase jet fans of 1.2 kW and 0.24 kW each, MCCB feeder with starters for 4 no. Axial Fresh Air fan as per required capacity & 4 EA Axial Exhaust fan not more than as per required capacity, controlled by 6 EA CO Sensors, with suitable incomer MCCB, metering panel, aluminium bus bar, PLC logic controller with necessary internal control wiring etc.The scope of work includes the Ventilation fans operation by getting of feed back from CO sensors & Fire Panel.
SITC 0 F ELECTRICAL PLC PANEL 1 Supply, installation, testing and commissioning of Electrical cum PLC Panel ror 1st Basement & 4th Basement with MCB feeders with starters for 15 EA dual speed 3 phase jet fans of 1.2 kW and 0.24 kW each, MCCB feeder with starters for 2 EA Axial Exhaust fan not more than as per reouired capacitv, contr9lk@tiy7 EA CO Sensors, withsuitable incomer MCCB, metering panel, aluminium bus bar, PLC logic controller with necessary internal control wiring etc. The scope of work includes the Ventilation fans operation by getting of feed back from CO sensors & Fire Panel.
SITC JET FANS WITH SILENCERS SITC of Ceiling Mounted Centrifugal Jet Fans Supply, installing, testing and commissioning of Ductless Ventilation / Centrifugal Jet fans for ventilation and Smoke Extraction along with silencers on both sides. The fan shall suction from bottom side through guided vanes. Jet fan to be of complete height up to 310 mm including impeller dia and having thrust of 24N. The fan shall be suitable for 250 °C for 2 Hrs operations as per EN 12101-3. Each fan shall be complete with dual speed motor and aerodynamical adjustable pitch die cast aluminium impeller. Casing shall be made of Hot dipped Galvanized steel. The Motor shall be run on the electrical power suitable for 415V / 3Ph / 50Hz. Note : Final quantity of Jet fans shall be decided after CFD analysis. All other fan mounting / ceiling suspending accesories will be provide with the fan.
7Cx2.5M2M CONTROL CABLES Control Wire & Cables Supply & laying of FRLS type Armoured Cabling work for Jet Fans, Tube Axial Fans & CO Sensors. For Jet Fans (7 Core, 2.5 Sq. mm.)
4Cx10M2M CONTROL CABLES Supply & laying of FRLS type Armoured Cabling work for Tube Axail Fans- 4 Core, 10.0 Sq. mm.
2Cx1M2M CONTROL CABLES Supply & laying of FRLS type Armoured Cabling work for CO Sensors- 2 Core, 1.0 Sq. mm.
SITC 600 x 75 x 2 MM THK CABLE TRAY Supply and Installation of 600 x 75 x 2 mm GI Perforated Cable Tray with required support structure all complete work.
SI EX AND FA AIR LOUVERS Fresh air Lowers Supply & Installation of Exhaust and Fresh air louvers.
DYN, CHEM FLUSHING AND PASS CHWP NETWK Carrying out Dynamic Flushing, Chemical Flushing and Passivation of entire Chilled water piping Network. Nitrite as N02 to be maintained at min. 700 ppm.
SITC RTD, PT-100 Supply, Installation, Testing & Commissioning of Dual output Duplex type, PT — 100, with accuracy of +/-0.25% of span, spring loaded mineral insulated three (3) wire RTD assembly. Element lead size shall be 18 AWG. The insulation resistance at 540 Deg C shall not be less than SM ohms. Repeatability over full range shall be better than 0.02%. RTDs shall be ungrounded. RTD shall be supplied as an assembly complete with thermowells meeting ANSI 19.3 (latest) requirements. The temperature transmitter output shall be 0-20mA or 4-20mA configurable module also note range of RTDs 0 to 50 Deg C.
SITC ARMOURED CABLE 2Px1.5 Sq. mm Supply, Installation, Testing & Commissioning of 2P X 1.5 Sq. mm armoured ATC, PVC Insulated, overall shielded, Inner sheathed, FRLS PVC Outer sheathed cable, tinned copper, Shielded, twisted pair cable to be used and Hard-wired connection to be provided up to DCS PLC panel inside the utility tunnel near GIFT Battery
P&F EWC Wall Mount with Seat & Lid Providing and Fixing white vitreous wall mounted EWC with Seat cover and lid including Cast Iron chair bracket and necessary bolts and nuts complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required to the satisfaction of Engineer-In-Charge.
P&F PVC Concealed Flushing Cistern Providing and fixing P.V.C. concealed low level flushing cistern with Flush Plate conforming to IS : 7231, with all fittings and fixtures complete with cutting and making good the walls and floors wherever required to the satisfaction of Engineer-In-Charge complete.
P&F Undercounter China Wash Basin Providing & fixing of first quality white vitreous undercounter china Washbasin as per product detail, including specially fabricated C.l. brackets with studs painted with two or three coats of enamel paint of approved shade over a coat of primer complete including filling gap between counter and wash basin with approved sanitary grade material cutting and making good the walls where required.
P&F CP Grid Drain Providing and fixing Grid Drain (Without Overflow and with Full thread) (Waste Coupling) in Polished Chrome f approved make and conforming to Manufacturers Standards.
P&F Urinal Basin with EFS Providing and fixing white vitreous china flat back urinal basin with Integrated EFS of 635mm x 395mm x 420mm size with standard flush pipe and G.l clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever require etc. complete of approved make fixed as per manufacturers specifications.
P&F CP Bottle Trap Providing and Fixing Lavatory Bottle Trap, without Drain, in polished chrome of approved make and conforming to Manufacturers Standards.
P&F 15 mm Braided Hose Pipe Providing and fixing braided hose pipe with 1 no of 15mm nominal bore heavy rating CP brass inlet with unions at end for connection of angular valve to basin as per product detail complete and conforming to Manufacturers Standards.
P&F Brass Bib Tap Providing and Fixing Brass Bib Tap with wall flange in Polished Chrome of approved Quality and conforming to Manufacturers Standards.
P&F 2-way Brass Bib Tap Providing and Fixing 2-Way Brass Bib Tap with wall flange in Polished Chrome of approved Quality and conforming to Manufacturers Standards.
P&F Health Faucet with Metal Hose & Holder Providing and Fixing Health Faucet with metal hose and Holder in Polished Chrome of approved quality and conforming to Manufacturers Standards.
P&F 15 mm CP Brass Angle Valve Providing and fixing C.P. brass angle valve for Pillar tap, and Sink Cock of approved quality conforming to IS:8931 of 15mm nominal bore.
P&F SS Kitchen Sink Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink without drain board 510x432 mm mm and bowl depth 190 mm.
P&F 15 mm CP Brass Pillar Cock Providing and fixing C.P. brass pillar cock for basin points of approved quality conforming to Manufacturers standards of 15mm nominal bore.
P&F 15 mm CP Brass Sink Cock Providing and fixing C.P. brass wall mounted Sink cock with extended swinging spout for Kitchen Sink points of approved quality conforming to Manufacturers standards of 15mm nominal bore.
P&F Handicap Toilet Set Providing and Fixing Handicap Toilet set including EWC, Cistern, Seat Cover, Fittings, Washbasin, Hinged Rail, Grab Bar and Faucet with Spatula Lever including Cast Iron chair bracket and necessary bolts and nuts complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required to the satisfaction of Engineer-In-Charge.
P&F 700 x 500 mm Mirror Supply and installation of Mirror 700mm x 500mm of approved make with back support on 12 mm Ply fixed to wall with approved quality fasteners of Hilti or equivalent. The mirror to be fixed to the ply board with suitable adhesive tape of 3M and with CP Brass Screws with CP brass washer and to be fixed as per drawings and to the satisfaction of Engineer-In-Charge.
P&F Liquid Soap Dispenser Providing and fixing Liquid Soap Dispenser in ABS plastic with all necessary accessories and fittings confirming to manufacturers specifications and including, cutting, chasing in walls and making good to the satisfaction of Engineer in Charge etc. complete.
P&F Toilet Paper Dispenser Providing and fixing Toilet Paper Dispenser with all necessary accessories and fittings confirming to manufacturers specifications and including, cutting, chasing in walls and making good to the satisfaction of Engineer IN Charge etc. complete.
P&F CP Towel Ring Providing and Fixing Towel Ring in Polished chrome of approved make and conforming to Manufacturers Standards.
P&F Hygienic Hand Drier Providing and Fixing of Solid state, no touch operating, fully hygienic hand drier with single blower, with time delay, summer & winter control, music while drying, volume & ON/OFF controls, The hand Drier shall be installed as per manufacturers directions. The rate shall be inclusive of all the fixtures and fasteners required for fixing, labour, material etc. including making good of any damage to the wall and finishing to the satisfaction of Engineer-In- Charge.
P&F Tissue Paper Dispenser Providing and Fixing of Tissue Paper Dispenser. The Tissue Paper Dispenser shall be installed as per manufacturers directions. The rate shall be inclusive of all the fixtures and fasteners required for fixing, labour, material etc. including making good of any damage to the wall and finishing to the satisfaction of Engineer-In-Charge.
SITC of 15 mm CPVC Pipe concealed with fittings Supply, Installation, Testing and Commissioning CPVC (Chlorinated Poly Vinyl Chloride) water supply pipes with pipe as per CTS SDR 11 (operating pressure - 7 Bar @ 82 Deg C and 28 Bar @ 27 Deg C) for pipes from 1/2 Inch to 2 Inch as per IS 15778:2007. Schedule 40 pipes shall be used for pipes from 2-1/2 Inch to 6 Inch. Pipes shall be joined using solvent welded CPVC fittings i.e. Tees, Elbows, Couplers, Unions, Reducers, bushings etc. including transition fittings (connection between CPVC & metal pipe/GI) i.e. Brass Adaptors (both Male & Female threaded) conforming to ASTM D-2846 along with necessary supports viz., split clamps with anchor fastener to RCC or masonry pedestals and battens, if required as per drawing/detail, hydro testing and as per technical specifications or as directed by the Project Manager. CPVC solvent cement conforming to ASTM F-493. All termination points for installation of faucets shall have brass termination fittings. Installation shall be to as per Technical Manual of manufacturer of pipes & fittings. Cost shall be inclusive of making maximum of 7.5 cm x 7.5 cm chase in wall using chase cutter and floors for the pipe, making good the same by using 1:2 cement mortar over the wire mesh and providing protection to embedded pipes and fittings (in wall chase) by wrapping two layers of 400 micron polythene sheet including proper overlaps on joints, support in the form of galvanized clamps, fastener complete as required. Internal toilet, Concealed work in wall, floor or Ground, including cutting chases and making good the walls etc. complete as per specifications & to the satisfaction of Engineer in Charge. (For pipes Embedded in Wall)
SITC of 20 mm CPVC Pipe concealed with fittings Supply, Installation, Testing and Commissioning CPVC (Chlorinated Poly Vinyl Chloride) water supply pipes with pipe as per CTS SDR 11 (operating pressure - 7 Bar @ 82 Deg C and 28 Bar @ 27 Deg C) for pipes from 1/2 Inch to 2 Inch as per IS 15778:2007. Schedule 40 pipes shall be used for pipes from 2-1/2 Inch to 6 Inch. Pipes shall be joined using solvent welded CPVC fittings i.e. Tees, Elbows, Couplers, Unions, Reducers, bushings etc. including transition fittings (connection between CPVC & metal pipe/GI) i.e. Brass Adaptors (both Male & Female threaded) conforming to ASTM D-2846 along with necessary supports viz., split clamps with anchor fastener to RCC or masonry pedestals and battens, if required as per drawing/detail, hydro testing and as per technical specifications or as directed by the Project Manager. CPVC solvent cement conforming to ASTM F-493. All termination points for installation of faucets shall have brass termination fittings. Installation shall be to as per Technical Manual of manufacturer of pipes & fittings. Cost shall be inclusive of making maximum of 7.5 cm x 7.5 cm chase in wall using chase cutter and floors for the pipe, making good the same by using 1:2 cement mortar over the wire mesh and providing protection to embedded pipes and fittings (in wall chase) by wrapping two layers of 400 micron polythene sheet including proper overlaps on joints, support in the form of galvanized clamps, fastener complete as required. Internal toilet, Concealed work in wall, floor or Ground, including cutting chases and making good the walls etc. complete as per specifications & to the satisfaction of Engineer in Charge. (For pipes Embedded in Wall)
SITC of 25 mm CPVC Pipe concealed with fittings Supply, Installation, Testing and Commissioning CPVC (Chlorinated Poly Vinyl Chloride) water supply pipes with pipe as per CTS SDR 11 (operating pressure - 7 Bar @ 82 Deg C and 28 Bar @ 27 Deg C) for pipes from 1/2 Inch to 2 Inch as per IS 15778:2007. Schedule 40 pipes shall be used for pipes from 2-1/2 Inch to 6 Inch. Pipes shall be joined using solvent welded CPVC fittings i.e. Tees, Elbows, Couplers, Unions, Reducers, bushings etc. including transition fittings (connection between CPVC & metal pipe/GI) i.e. Brass Adaptors (both Male & Female threaded) conforming to ASTM D-2846 along with necessary supports viz., split clamps with anchor fastener to RCC or masonry pedestals and battens, if required as per drawing/detail, hydro testing and as per technical specifications or as directed by the Project Manager. CPVC solvent cement conforming to ASTM F-493. All termination points for installation of faucets shall have brass termination fittings. Installation shall be to as per Technical Manual of manufacturer of pipes & fittings. Cost shall be inclusive of making maximum of 7.5 cm x 7.5 cm chase in wall using chase cutter and floors for the pipe, making good the same by using 1:2 cement mortar over the wire mesh and providing protection to embedded pipes and fittings (in wall chase) by wrapping two layers of 400 micron polythene sheet including proper overlaps on joints, support in the form of galvanized clamps, fastener complete as required. Internal toilet, Concealed work in wall, floor or Ground, including cutting chases and making good the walls etc. complete as per specifications & to the satisfaction of Engineer in Charge. (For pipes Embedded in Wall)
SITC of 32 mm CPVC Pipe concealed with fittings Supply, Installation, Testing and Commissioning CPVC (Chlorinated Poly Vinyl Chloride) water supply pipes with pipe as per CTS SDR 11 (operating pressure - 7 Bar @ 82 Deg C and 28 Bar @ 27 Deg C) for pipes from 1/2 Inch to 2 Inch as per IS 15778:2007. Schedule 40 pipes shall be used for pipes from 2-1/2 Inch to 6 Inch. Pipes shall be joined using solvent welded CPVC fittings i.e. Tees, Elbows, Couplers, Unions, Reducers, bushings etc. including transition fittings (connection between CPVC & metal pipe/GI) i.e. Brass Adaptors (both Male & Female threaded) conforming to ASTM D-2846 along with necessary supports viz., split clamps with anchor fastener to RCC or masonry pedestals and battens, if required as per drawing/detail, hydro testing and as per technical specifications or as directed by the Project Manager. CPVC solvent cement conforming to ASTM F-493. All termination points for installation of faucets shall have brass termination fittings. Installation shall be to as per Technical Manual of manufacturer of pipes & fittings. Cost shall be inclusive of making maximum of 7.5 cm x 7.5 cm chase in wall using chase cutter and floors for the pipe, making good the same by using 1:2 cement mortar over the wire mesh and providing protection to embedded pipes and fittings (in wall chase) by wrapping two layers of 400 micron polythene sheet including proper overlaps on joints, support in the form of galvanized clamps, fastener complete as required. Internal toilet, Concealed work in wall, floor or Ground, including cutting chases and making good the walls etc. complete as per specifications & to the satisfaction of Engineer in Charge. (For pipes Embedded in Wall)
SITC of 40 mm CPVC Pipe concealed with fittings Supply, Installation, Testing and Commissioning CPVC (Chlorinated Poly Vinyl Chloride) water supply pipes with pipe as per CTS SDR 11 (operating pressure - 7 Bar @ 82 Deg C and 28 Bar @ 27 Deg C) for pipes from 1/2 Inch to 2 Inch as per IS 15778:2007. Schedule 40 pipes shall be used for pipes from 2-1/2 Inch to 6 Inch. Pipes shall be joined using solvent welded CPVC fittings i.e. Tees, Elbows, Couplers, Unions, Reducers, bushings etc. including transition fittings (connection between CPVC & metal pipe/GI) i.e. Brass Adaptors (both Male & Female threaded) conforming to ASTM D-2846 along with necessary supports viz., split clamps with anchor fastener to RCC or masonry pedestals and battens, if required as per drawing/detail, hydro testing and as per technical specifications or as directed by the Project Manager. CPVC solvent cement conforming to ASTM F-493. All termination points for installation of faucets shall have brass termination fittings. Installation shall be to as per Technical Manual of manufacturer of pipes & fittings. Cost shall be inclusive of making maximum of 7.5 cm x 7.5 cm chase in wall using chase cutter and floors for the pipe, making good the same by using 1:2 cement mortar over the wire mesh and providing protection to embedded pipes and fittings (in wall chase) by wrapping two layers of 400 micron polythene sheet including proper overlaps on joints, support in the form of galvanized clamps, fastener complete as required. Internal toilet, Concealed work in wall, floor or Ground, including cutting chases and making good the walls etc. complete as per specifications & to the satisfaction of Engineer in Charge. (For pipes Embedded in Wall)
SITC of 50 mm CPVC Pipe concealed with fittings Supply, Installation, Testing and Commissioning CPVC (Chlorinated Poly Vinyl Chloride) water supply pipes with pipe as per CTS SDR 11 (operating pressure - 7 Bar @ 82 Deg C and 28 Bar @ 27 Deg C) for pipes from 1/2 Inch to 2 Inch as per IS 15778:2007. Schedule 40 pipes shall be used for pipes from 2-1/2 Inch to 6 Inch. Pipes shall be joined using solvent welded CPVC fittings i.e. Tees, Elbows, Couplers, Unions, Reducers, bushings etc. including transition fittings (connection between CPVC & metal pipe/GI) i.e. Brass Adaptors (both Male & Female threaded) conforming to ASTM D-2846 along with necessary supports viz., split clamps with anchor fastener to RCC or masonry pedestals and battens, if required as per drawing/detail, hydro testing and as per technical specifications or as directed by the Project Manager. CPVC solvent cement conforming to ASTM F-493. All termination points for installation of faucets shall have brass termination fittings. Installation shall be to as per Technical Manual of manufacturer of pipes & fittings. Cost shall be inclusive of making maximum of 7.5 cm x 7.5 cm chase in wall using chase cutter and floors for the pipe, making good the same by using 1:2 cement mortar over the wire mesh and providing protection to embedded pipes and fittings (in wall chase) by wrapping two layers of 400 micron polythene sheet including proper overlaps on joints, support in the form of galvanized clamps, fastener complete as required. Internal toilet, Concealed work in wall, floor or Ground, including cutting chases and making good the walls etc. complete as per specifications & to the satisfaction of Engineer in Charge. (For pipes Embedded in Wall)
SITC of 25 mm CPVC Pipe exposed with fittings Supply, Installation, Testing and Commissioning CPVC (Chlorinated Poly Vinyl Chloride) water supply pipes with pipe as per CTS SDR 11 (operating pressure - 7 Bar @ 82 Deg C and 28 Bar @ 27 Deg C) for pipes from 1/2 Inch to 2 Inch as per IS 15778:2007. Schedule 40 pipes shall be used for pipes from 2-1/2 Inch to 6 Inch and Schedule 80 pipes shall be used for pipes of 8 inch. Pipes shall be joined using solvent welded CPVC fittings i.e. Tees, Elbows, Couplers, Unions, Reducers, brushings etc. including transition fittings (connection between CPVC & metal pipe/GI) i.e. Brass Adaptors (both Male & Female threaded) conforming to ASTM D-2846 along with necessary supports viz., split clamps with anchor fastener to RCC or masonry pedestals and battens, if required as per drawing/detail, hydro testing and as per technical specifications or as directed by the Project Manager. ASTM F 44 with only CPVC solvent cement conforming to ASTM F-493. Fixing/supporting the pipes (& fittings) at wall/ceiling level supported by galvanized clamps, hangers etc., as per specification. Exposed pipes to be painted of legends with direction arrow. MS pipe sleeves suitable higher size shall be provided wherever the pipes are crossing the fire rated walls/ floors slab and sealing the sleeves with glass wool in between and fire sealant compound at either end all as per Project Manager's/ Consultant requirement. All termination points for installation of faucets shall have brass termination fittings. Installation shall be to as per Technical Manual of manufacturer of pipes & fittings. As per direction of Engineer in Charge & specifications. (For Exposed piping inside Shafts, Ceiling, Terrace and Basement)
SITC of 32 mm CPVC Pipe exposed with fittings Supply, Installation, Testing and Commissioning CPVC (Chlorinated Poly Vinyl Chloride) water supply pipes with pipe as per CTS SDR 11 (operating pressure - 7 Bar @ 82 Deg C and 28 Bar @ 27 Deg C) for pipes from 1/2 Inch to 2 Inch as per IS 15778:2007. Schedule 40 pipes shall be used for pipes from 2-1/2 Inch to 6 Inch and Schedule 80 pipes shall be used for pipes of 8 inch. Pipes shall be joined using solvent welded CPVC fittings i.e. Tees, Elbows, Couplers, Unions, Reducers, brushings etc. including transition fittings (connection between CPVC & metal pipe/GI) i.e. Brass Adaptors (both Male & Female threaded) conforming to ASTM D-2846 along with necessary supports viz., split clamps with anchor fastener to RCC or masonry pedestals and battens, if required as per drawing/detail, hydro testing and as per technical specifications or as directed by the Project Manager. ASTM F 44 with only CPVC solvent cement conforming to ASTM F-493. Fixing/supporting the pipes (& fittings) at wall/ceiling level supported by galvanized clamps, hangers etc., as per specification. Exposed pipes to be painted of legends with direction arrow. MS pipe sleeves suitable higher size shall be provided wherever the pipes are crossing the fire rated walls/ floors slab and sealing the sleeves with glass wool in between and fire sealant compound at either end all as per Project Manager's/ Consultant requirement. All termination points for installation of faucets shall have brass termination fittings. Installation shall be to as per Technical Manual of manufacturer of pipes & fittings. As per direction of Engineer in Charge & specifications. (For Exposed piping inside Shafts, Ceiling, Terrace and Basement)
SITC of 40 mm CPVC Pipe exposed with fittings Supply, Installation, Testing and Commissioning CPVC (Chlorinated Poly Vinyl Chloride) water supply pipes with pipe as per CTS SDR 11 (operating pressure - 7 Bar @ 82 Deg C and 28 Bar @ 27 Deg C) for pipes from 1/2 Inch to 2 Inch as per IS 15778:2007. Schedule 40 pipes shall be used for pipes from 2-1/2 Inch to 6 Inch and Schedule 80 pipes shall be used for pipes of 8 inch. Pipes shall be joined using solvent welded CPVC fittings i.e. Tees, Elbows, Couplers, Unions, Reducers, brushings etc. including transition fittings (connection between CPVC & metal pipe/GI) i.e. Brass Adaptors (both Male & Female threaded) conforming to ASTM D-2846 along with necessary supports viz., split clamps with anchor fastener to RCC or masonry pedestals and battens, if required as per drawing/detail, hydro testing and as per technical specifications or as directed by the Project Manager. ASTM F 44 with only CPVC solvent cement conforming to ASTM F-493. Fixing/supporting the pipes (& fittings) at wall/ceiling level supported by galvanized clamps, hangers etc., as per specification. Exposed pipes to be painted of legends with direction arrow. MS pipe sleeves suitable higher size shall be provided wherever the pipes are crossing the fire rated walls/ floors slab and sealing the sleeves with glass wool in between and fire sealant compound at either end all as per Project Manager's/ Consultant requirement. All termination points for installation of faucets shall have brass termination fittings. Installation shall be to as per Technical Manual of manufacturer of pipes & fittings. As per direction of Engineer in Charge & specifications. (For Exposed piping inside Shafts, Ceiling, Terrace and Basement)
SITC of 50 mm CPVC Pipe exposed with fittings Supply, Installation, Testing and Commissioning CPVC (Chlorinated Poly Vinyl Chloride) water supply pipes with pipe as per CTS SDR 11 (operating pressure - 7 Bar @ 82 Deg C and 28 Bar @ 27 Deg C) for pipes from 1/2 Inch to 2 Inch as per IS 15778:2007. Schedule 40 pipes shall be used for pipes from 2-1/2 Inch to 6 Inch and Schedule 80 pipes shall be used for pipes of 8 inch. Pipes shall be joined using solvent welded CPVC fittings i.e. Tees, Elbows, Couplers, Unions, Reducers, brushings etc. including transition fittings (connection between CPVC & metal pipe/GI) i.e. Brass Adaptors (both Male & Female threaded) conforming to ASTM D-2846 along with necessary supports viz., split clamps with anchor fastener to RCC or masonry pedestals and battens, if required as per drawing/detail, hydro testing and as per technical specifications or as directed by the Project Manager. ASTM F 44 with only CPVC solvent cement conforming to ASTM F-493. Fixing/supporting the pipes (& fittings) at wall/ceiling level supported by galvanized clamps, hangers etc., as per specification. Exposed pipes to be painted of legends with direction arrow. MS pipe sleeves suitable higher size shall be provided wherever the pipes are crossing the fire rated walls/ floors slab and sealing the sleeves with glass wool in between and fire sealant compound at either end all as per Project Manager's/ Consultant requirement. All termination points for installation of faucets shall have brass termination fittings. Installation shall be to as per Technical Manual of manufacturer of pipes & fittings. As per direction of Engineer in Charge & specifications. (For Exposed piping inside Shafts, Ceiling, Terrace and Basement)
SITC of 65 mm CPVC Pipe exposed with fittings Supply, Installation, Testing and Commissioning CPVC (Chlorinated Poly Vinyl Chloride) water supply pipes with pipe as per CTS SDR 11 (operating pressure - 7 Bar @ 82 Deg C and 28 Bar @ 27 Deg C) for pipes from 1/2 Inch to 2 Inch as per IS 15778:2007. Schedule 40 pipes shall be used for pipes from 2-1/2 Inch to 6 Inch and Schedule 80 pipes shall be used for pipes of 8 inch. Pipes shall be joined using solvent welded CPVC fittings i.e. Tees, Elbows, Couplers, Unions, Reducers, brushings etc. including transition fittings (connection between CPVC & metal pipe/GI) i.e. Brass Adaptors (both Male & Female threaded) conforming to ASTM D-2846 along with necessary supports viz., split clamps with anchor fastener to RCC or masonry pedestals and battens, if required as per drawing/detail, hydro testing and as per technical specifications or as directed by the Project Manager. ASTM F 44 with only CPVC solvent cement conforming to ASTM F-493. Fixing/supporting the pipes (& fittings) at wall/ceiling level supported by galvanized clamps, hangers etc., as per specification. Exposed pipes to be painted of legends with direction arrow. MS pipe sleeves suitable higher size shall be provided wherever the pipes are crossing the fire rated walls/ floors slab and sealing the sleeves with glass wool in between and fire sealant compound at either end all as per Project Manager's/ Consultant requirement. All termination points for installation of faucets shall have brass termination fittings. Installation shall be to as per Technical Manual of manufacturer of pipes & fittings. As per direction of Engineer in Charge & specifications. (For Exposed piping inside Shafts, Ceiling, Terrace and Basement)
SITC of 80 mm CPVC Pipe exposed with fittings Supply, Installation, Testing and Commissioning CPVC (Chlorinated Poly Vinyl Chloride) water supply pipes with pipe as per CTS SDR 11 (operating pressure - 7 Bar @ 82 Deg C and 28 Bar @ 27 Deg C) for pipes from 1/2 Inch to 2 Inch as per IS 15778:2007. Schedule 40 pipes shall be used for pipes from 2-1/2 Inch to 6 Inch and Schedule 80 pipes shall be used for pipes of 8 inch. Pipes shall be joined using solvent welded CPVC fittings i.e. Tees, Elbows, Couplers, Unions, Reducers, brushings etc. including transition fittings (connection between CPVC & metal pipe/GI) i.e. Brass Adaptors (both Male & Female threaded) conforming to ASTM D-2846 along with necessary supports viz., split clamps with anchor fastener to RCC or masonry pedestals and battens, if required as per drawing/detail, hydro testing and as per technical specifications or as directed by the Project Manager. ASTM F 44 with only CPVC solvent cement conforming to ASTM F-493. Fixing/supporting the pipes (& fittings) at wall/ceiling level supported by galvanized clamps, hangers etc., as per specification. Exposed pipes to be painted of legends with direction arrow. MS pipe sleeves suitable higher size shall be provided wherever the pipes are crossing the fire rated walls/ floors slab and sealing the sleeves with glass wool in between and fire sealant compound at either end all as per Project Manager's/ Consultant requirement. All termination points for installation of faucets shall have brass termination fittings. Installation shall be to as per Technical Manual of manufacturer of pipes & fittings. As per direction of Engineer in Charge & specifications. (For Exposed piping inside Shafts, Ceiling, Terrace and Basement)
SITC of 100 mm CPVC Pipe exposed with fittings Supply, Installation, Testing and Commissioning CPVC (Chlorinated Poly Vinyl Chloride) water supply pipes with pipe as per CTS SDR 11 (operating pressure - 7 Bar @ 82 Deg C and 28 Bar @ 27 Deg C) for pipes from 1/2 Inch to 2 Inch as per IS 15778:2007. Schedule 40 pipes shall be used for pipes from 2-1/2 Inch to 6 Inch and Schedule 80 pipes shall be used for pipes of 8 inch. Pipes shall be joined using solvent welded CPVC fittings i.e. Tees, Elbows, Couplers, Unions, Reducers, brushings etc. including transition fittings (connection between CPVC & metal pipe/GI) i.e. Brass Adaptors (both Male & Female threaded) conforming to ASTM D-2846 along with necessary supports viz., split clamps with anchor fastener to RCC or masonry pedestals and battens, if required as per drawing/detail, hydro testing and as per technical specifications or as directed by the Project Manager. ASTM F 44 with only CPVC solvent cement conforming to ASTM F-493. Fixing/supporting the pipes (& fittings) at wall/ceiling level supported by galvanized clamps, hangers etc., as per specification. Exposed pipes to be painted of legends with direction arrow. MS pipe sleeves suitable higher size shall be provided wherever the pipes are crossing the fire rated walls/ floors slab and sealing the sleeves with glass wool in between and fire sealant compound at either end all as per Project Manager's/ Consultant requirement. All termination points for installation of faucets shall have brass termination fittings. Installation shall be to as per Technical Manual of manufacturer of pipes & fittings. As per direction of Engineer in Charge & specifications. (For Exposed piping inside Shafts, Ceiling, Terrace and Basement)
SITC of 150 mm CPVC Pipe exposed with fittings Supply, Installation, Testing and Commissioning CPVC (Chlorinated Poly Vinyl Chloride) water supply pipes with pipe as per CTS SDR 11 (operating pressure - 7 Bar @ 82 Deg C and 28 Bar @ 27 Deg C) for pipes from 1/2 Inch to 2 Inch as per IS 15778:2007. Schedule 40 pipes shall be used for pipes from 2-1/2 Inch to 6 Inch and Schedule 80 pipes shall be used for pipes of 8 inch. Pipes shall be joined using solvent welded CPVC fittings i.e. Tees, Elbows, Couplers, Unions, Reducers, brushings etc. including transition fittings (connection between CPVC & metal pipe/GI) i.e. Brass Adaptors (both Male & Female threaded) conforming to ASTM D-2846 along with necessary supports viz., split clamps with anchor fastener to RCC or masonry pedestals and battens, if required as per drawing/detail, hydro testing and as per technical specifications or as directed by the Project Manager. ASTM F 44 with only CPVC solvent cement conforming to ASTM F-493. Fixing/supporting the pipes (& fittings) at wall/ceiling level supported by galvanized clamps, hangers etc., as per specification. Exposed pipes to be painted of legends with direction arrow. MS pipe sleeves suitable higher size shall be provided wherever the pipes are crossing the fire rated walls/ floors slab and sealing the sleeves with glass wool in between and fire sealant compound at either end all as per Project Manager's/ Consultant requirement. All termination points for installation of faucets shall have brass termination fittings. Installation shall be to as per Technical Manual of manufacturer of pipes & fittings. As per direction of Engineer in Charge & specifications. (For Exposed piping inside Shafts, Ceiling, Terrace and Basement)
SITC of 200 mm CPVC Pipe exposed with fittings Supply, Installation, Testing and Commissioning CPVC (Chlorinated Poly Vinyl Chloride) water supply pipes with pipe as per CTS SDR 11 (operating pressure - 7 Bar @ 82 Deg C and 28 Bar @ 27 Deg C) for pipes from 1/2 Inch to 2 Inch as per IS 15778:2007. Schedule 40 pipes shall be used for pipes from 2-1/2 Inch to 6 Inch and Schedule 80 pipes shall be used for pipes of 8 inch. Pipes shall be joined using solvent welded CPVC fittings i.e. Tees, Elbows, Couplers, Unions, Reducers, brushings etc. including transition fittings (connection between CPVC & metal pipe/GI) i.e. Brass Adaptors (both Male & Female threaded) conforming to ASTM D-2846 along with necessary supports viz., split clamps with anchor fastener to RCC or masonry pedestals and battens, if required as per drawing/detail, hydro testing and as per technical specifications or as directed by the Project Manager. ASTM F 44 with only CPVC solvent cement conforming to ASTM F-493. Fixing/supporting the pipes (& fittings) at wall/ceiling level supported by galvanized clamps, hangers etc., as per specification. Exposed pipes to be painted of legends with direction arrow. MS pipe sleeves suitable higher size shall be provided wherever the pipes are crossing the fire rated walls/ floors slab and sealing the sleeves with glass wool in between and fire sealant compound at either end all as per Project Manager's/ Consultant requirement. All termination points for installation of faucets shall have brass termination fittings. Installation shall be to as per Technical Manual of manufacturer of pipes & fittings. As per direction of Engineer in Charge & specifications. (For Exposed piping inside Shafts, Ceiling, Terrace and Basement)
SITC of Brass Float valve 50 mm NB Supply, installation, testing and commissioning of approved quality high pressure rated Cast Brass Float Valve 50 mm NB with copper ball float and brass rods of required length suitable for test pressure of not less than 20 Kg/sqcm as per specification & to the satisfaction of Engineer-In-Charge.
SITC of Brass Float valve 65 mm NB Supply, installation, testing and commissioning of approved quality high pressure rated Cast Brass Float Valve 65 mm NB with copper ball float and brass rods of required length suitable for test pressure of not less than 20 Kg/sqcm as per specification & to the satisfaction of Engineer-In-Charge.
SITC of Brass Float valve 80 mm NB Supply, installation, testing and commissioning of approved quality high pressure rated Cast Brass Float Valve 80 mm NB with copper ball float and brass rods of required length suitable for test pressure of not less than 20 Kg/sqcm as per specification & to the satisfaction of Engineer-In-Charge.
SITC of Gun metal Gate Valve 40 mm NB Supply, Installation, Testing and Commissioning of Gun Metal Gate Valve 40 mm NB with CI Wheel of approved make of the following diameter having pressure rating of PN 20. Installation to be done as per specification and to the satisfaction of the Engineer-In-Charge.
SITC of Gun metal Gate Valve 50 mm NB Supply, Installation, Testing and Commissioning of Gun Metal Gate Valve 50 mm NB with CI Wheel of approved make of the following diameter having pressure rating of PN 20. Installation to be done as per specification and to the satisfaction of the Engineer-In-Charge.
SITC of Gun metal Gate Valve 65 mm NB Supply, Installation, Testing and Commissioning of Gun Metal Gate Valve 65 mm NB with CI Wheel of approved make of the following diameter having pressure rating of PN 20. Installation to be done as per specification and to the satisfaction of the Engineer-In-Charge.
SITC of Gun metal Gate Valve 80 mm NB Supply, Installation, Testing and Commissioning of Gun Metal Gate Valve 80 mm NB with CI Wheel of approved make of the following diameter having pressure rating of PN 20. Installation to be done as per specification and to the satisfaction of the Engineer-In-Charge.
SITC of Gun metal Gate Valve 20 mm NB Supply, Installation, Testing and Commissioning of Gun Metal Gate Valve 20 mm NB with CI Wheel of approved make (Screwed ends) of the following diameter having pressure rating of PN 20. Installation to be done as per specification and to the satisfaction of the Engineer-In-Charge.
SITC of Gun metal Gate Valve 25 mm NB Supply, Installation, Testing and Commissioning of Gun Metal Gate Valve 25 mm NB with CI Wheel of approved make (Screwed ends) of the following diameter having pressure rating of PN 20. Installation to be done as per specification and to the satisfaction of the Engineer-In-Charge.
SITC of Gun metal Gate Valve 32 mm NB Supply, Installation, Testing and Commissioning of Gun Metal Gate Valve 32 mm NB with CI Wheel of approved make (Screwed ends) of the following diameter having pressure rating of PN 20. Installation to be done as per specification and to the satisfaction of the Engineer-In-Charge.
SITC of Brass Ball Valve 25 mm NB Supply, installation, testing and commissioning of PN 16 full bore, lever operated, forged brass body, quarter turn, ball valve 25 mm NB provided with forged brass hard chrome plated ball, Including necessary nipple, coupling, union etc.
SITC of Brass Ball Valve 32 mm NB Supply, installation, testing and commissioning of PN 16 full bore, lever operated, forged brass body, quarter turn, ball valve 32 mm NB provided with forged brass hard chrome plated ball, Including necessary nipple, coupling, union etc.
SITC of Brass Ball Valve 40 mm NB Supply, installation, testing and commissioning of PN 16 full bore, lever operated, forged brass body, quarter turn, ball valve 40 mm NB provided with forged brass hard chrome plated ball, Including necessary nipple, coupling, union etc.
SITC of Brass Ball Valve 50 mm NB Supply, installation, testing and commissioning of PN 16 full bore, lever operated, forged brass body, quarter turn, ball valve 50 mm NB provided with forged brass hard chrome plated ball, Including necessary nipple, coupling, union etc.
SITC of CI butterfly valve 65 mm NB Supply, installation, testing and commissioning of 65 mm NB CI butterfly valves wafer type, lever operated, SS 304 / 316 disc, O-ring and PN 20 rating confirming to IS 13095 including all fitting and accessories.
SITC of CI butterfly valve 80 mm NB Supply, installation, testing and commissioning of 80 mm NB CI butterfly valves wafer type, lever operated, SS 304 / 316 disc, O-ring and PN 20 rating confirming to IS 13095 including all fitting and accessories.
SITC of CI butterfly valve 100 mm NB Supply, installation, testing and commissioning of 100 mm NB CI butterfly valves wafer type, lever operated, SS 304 / 316 disc, O-ring and PN 20 rating confirming to IS 13095 including all fitting and accessories.
SITC of CI butterfly valve 150 mm NB Supply, installation, testing and commissioning of 150 mm NB CI butterfly valves wafer type, lever operated, SS 304 / 316 disc, O-ring and PN 20 rating confirming to IS 13095 including all fitting and accessories.
SITC of CI butterfly valve 200 mm NB Supply, installation, testing and commissioning of 200 mm NB CI butterfly valves wafer type, lever / gear operated, SS 304 / 316 disc, O-ring and PN 20 rating confirming to IS 13095 including all fitting and accessories.
SITC of 40 mm NB Brass Pressure Reducing Valve Supply, Installation,Testing and Commissioning of 40 mm NB Brass pressure reducing valve of approved quality (screwed end) including fixing to the pipe line as per specifications and to the satisfaction of the Engineer-In-Charge.
SITC of 50 mm NB Brass Pressure Reducing Valve Supply, Installation,Testing and Commissioning of 50 mm NB Brass pressure reducing valve of approved quality (screwed end) including fixing to the pipe line as per specifications and to the satisfaction of the Engineer-In-Charge.
SITC of 65 mm NB Brass Pressure Reducing Valve Supply, Installation,Testing and Commissioning of 65 mm NB Brass pressure reducing valve of approved quality (screwed end) including fixing to the pipe line as per specifications and to the satisfaction of the Engineer-In-Charge.
SITC of 80 mm NB Brass Pressure Reducing Valve Supply, Installation,Testing and Commissioning of 80 mm NB Brass pressure reducing valve of approved quality (screwed end) including fixing to the pipe line as per specifications and to the satisfaction of the Engineer-In-Charge.
SITC of 100 mm NB Brass Pressure Reducing Valve Supply, Installation,Testing and Commissioning of 100 mm NB Brass pressure reducing valve of approved quality (screwed end) including fixing to the pipe line as per specifications and to the satisfaction of the Engineer-In-Charge.
P&F of 80 mm NB Electronic water meter Providing and fixing 80mm NB Dia Electronic water meter with RS 485 port and shall be modbus enabled with capability to provide data to the Building BMS system with all necessary accessories etc.with bolts, nuts, rubber insertions etc. complete as per specifications and to the satisfaction of the Engineer-In-Charge.
P&F of 65 mm NB Electronic water meter Providing and fixing 65mm NB Dia Electronic water meter with RS 485 port and shall be modbus enabled with capability to provide data to the Building BMS system with all necessary accessories etc.with bolts, nuts, rubber insertions etc. complete as per specifications and to the satisfaction of the Engineer-In-Charge.
SITC of 50 mm NB Gun metal NRV Supply, Installation, Testing & commissioning of 50 mm NB Dia gun metal non- return valve of approved quality (screwed end) including ofall accessories having pressure rating of 20Kg/sqcm, Bolts etc. as per Specifications and as directed by Engineer In Charge complete.
SITC of 65 mm NB Gun metal NRV Supply, Installation, Testing & commissioning 65 mm NB Dia gun metal non- return valve of approved quality (screwed end) including ofall accessories having pressure rating of 20Kg/sqcm, Bolts etc. as per Specifications and as directed by Engineer In Charge complete.
SITC of 80 mm NB Gun metal NRV Supply, Installation, Testing & commissioning 80 mm NB Dia gun metal non- return valve of approved quality (screwed end) including ofall accessories having pressure rating of 20Kg/sqcm, Bolts etc. as per Specifications and as directed by Engineer In Charge complete.
SITC of pressure gauge 0 - 16 kg/cm2 Supply, installation, testing and commissioning of glycerin filled Pressure gauge of following ranges with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer. 0 to 16.0 kg/cm2.
P&F of 20 mm NB Air release valve Providing and fixing 20mm Air release valve of approved quality with bolts, nuts, rubber insertions etc. complete including the tail pieces, tapers etc. if required including all the accessories and testing etc. complete as per specification & to the satisfaction of Engineer In Charge.
SITC of 65 mm NB Motorised Butterfly valve Supply, Installation, Testing & commissioning of 65 mm NB CI Motorised butterfly valve operating on level switches with auto panel for auto ON/OFF of fill the tank etc. complete. Rate to include cost of required cable & its installation with all required accessories etc. complete as per specifications & to the satisfaction of Engineer ln charge.
SITC of 80 mm NB Motorised Butterfly valve Supply, Installation, Testing & commissioning of 80 mm NB CI Motorised butterfly valve operating on level switches with auto panel for auto ON/OFF of fill the tank etc. complete. Rate to include cost of required cable & its installation with all required accessories etc. complete as per specifications & to the satisfaction of Engineer ln charge.
SITC of Water Quality Monitoring System Supply, Installation, Testing & commissioning of Water Quality Monitoring system with minimum parameter Ph, TDS, Turbidity/ TSS with BMS compellability. Rate to include cost of required cable & its installation with all required accessories etc. complete as required.
SITC of Water Cooler: Capacity - 80 Ltr Supply, Installation, Testing & commissioning of SS 304 water cooler having storage capacity 80 ltr & cooling capacity 40 ltr. Per hour @ an ambient temp of 45 deg. C. the outlet temp of the water should drop by 15 C. within a hour. The water cooler should be should be comprising of hermitically sealed compressor, fan motor, condensing unit, water tank surrounded by evaporating coil, thermostats, relay etc. complete with necessary inlet & outlet connection with drinking water tap. The body of the water cooler will be made of stainless steel.with Five year Maintenance Warranty.
SITC of SS 316 UV system: Capacity - 30 m3/hr Supply, Installation, Testing & commissioning of On-line auto UV system for disinfection of water, SS 316 UV housing with power unit (starter) and standard UV lamp. UV system should have arrangement to diagnose failure of UV lamp, all necessary piping & equipment etc. working at minimum pressure of 12-13 kg/sq.cm. as per specification. The Starter panel shall have RS485 Modbus enabled port for BMS integration.
SITC of SS 316 UV system: Capacity - 10.5 m3/hr Supply, Installation, Testing & commissioning of On-line auto UV system for disinfection of water, SS 316 UV housing with power unit (starter) and standard UV lamp. UV system should have arrangement to diagnose failure of UV lamp, all necessary piping & equipment etc. working at minimum pressure of 12-13 kg/sq.cm. as per specification. The Starter panel shall have RS485 Modbus enabled port for BMS integration.
SITC of 25 mm NB Water Hammer Arrestor Supply, installation, testing and commissioning of 25 mm NB Water hammer arrestor with Type K hard drawn copper barrel, hydro pneumatic air cushion and triple 'O' ring sealed pistons fixed screwed with unions and fixing acessories, nuts, bolts, gaskets, washers, supports etc., mating flanges to suit the piping material specified and in accordance with specification.
SITC of GI Pipe 65 mm class 'C' Supply, installation, testing and commissioning of 65 mm NB GI Pipe class 'C' (heavy duty) including all accessories such as screwed / welded joints, flanges, tees, reducers, clamps etc. including lift to all heights, welding, jointing, painting and inserted rubber gaskets, nuts, bolts etc. as required. Pipes shall be painted with one coat of primer & two coats synthetic enamel paint. shall be fixed in ceiling, walls, columns for all heights with hangers and fasteners In case of requirement of structural steel supports, shall be paid separately. (For pump room and upto OHWT filling)
SITC of GI Pipe 80 mm class 'C' Supply, installation, testing and commissioning of 80 mm NB GI Pipe class 'C' (heavy duty) including all accessories such as screwed / welded joints, flanges, tees, reducers, clamps etc. including lift to all heights, welding, jointing, painting and inserted rubber gaskets, nuts, bolts etc. as required. Pipes shall be painted with one coat of primer & two coats synthetic enamel paint. shall be fixed in ceiling, walls, columns for all heights with hangers and fasteners In case of requirement of structural steel supports, shall be paid separately. (For pump room and upto OHWT filling)
SITC of 40 mm uPVC pipe 6 kg/cm2 with fittings Providing and fixing 40 mm dia 6 KG/Sqcm UPVC Agriculture grade pipe confirming to IS: 4985 and fitting confirming to IS:7834 pipes ISi Marked brand, including chasing in solid masonary walls with groove cutting machine to required width and depth, making holes in brick or RCC wall as per requirement, clearing the debris, grouting of concealed pipes, making good the chase as mentioned, making good the wall and floors, and making connection with down take wherever required to satisfaction of engr / arch with proper care, protecting fittings & pipes till the final handing over etc. as directed by E-I-C complete as per specifications & drawing provided for all places, all heights & all levels etc.
SITC of 50 mm uPVC pipe 6 kg/cm2 with fittings Providing and fixing 50 mm dia 6 KG/Sqcm UPVC Agriculture grade pipe confirming to IS: 4985 and fitting confirming to IS:7834 pipes ISi Marked brand, including chasing in solid masonary walls with groove cutting machine to required width and depth, making holes in brick or RCC wall as per requirement, clearing the debris, grouting of concealed pipes, making good the chase as mentioned, making good the wall and floors, and making connection with down take wherever required to satisfaction of engr / arch with proper care, protecting fittings & pipes till the final handing over etc. as directed by E-I-C complete as per specifications & drawing provided for all places, all heights & all levels etc.
SITC of 75 mm uPVC pipe 6 kg/cm2 with fittings Providing and fixing 75 mm dia 6 KG/Sqcm UPVC Agriculture grade pipe confirming to IS: 4985 and fitting confirming to IS:7834 pipes ISi Marked brand, including chasing in solid masonary walls with groove cutting machine to required width and depth, making holes in brick or RCC wall as per requirement, clearing the debris, grouting of concealed pipes, making good the chase as mentioned, making good the wall and floors, and making connection with down take wherever required to satisfaction of engr / arch with proper care, protecting fittings & pipes till the final handing over etc. as directed by E-I-C complete as per specifications & drawing provided for all places, all heights & all levels etc.
SITC of 75 mm Low noise pipe with fittings Providing & Fixing of 75 mm dia Low noise pipe confirming to EN12056 with ring fit type including all fittings and accessories complete. The work including solvent jointing hydraulic testing the joints & pipes as mentioned in the specification etc. making holes including chasing in solid block / masonry walls with groove cutting machine to required width and depth, making holes in brick or RCC wall as per requirement ,clearing the debris, grouting of concealed pipes, making good the chase as mentioned, making good the wall and floors, making connection with down take to satisfaction of engineering in charge with proper care, protecting fittings & pipes till the final handing over etc. as directed by E-I-C complete as per specifications & drawing provided for all places, all heights & all levels.
SITC of 110 mm Low noise pipe with fittings Providing & Fixing of 110 mm dia Low noise pipe confirming to EN12056 with ring fit type including all fittings and accessories complete. The work including solvent jointing hydraulic testing the joints & pipes as mentioned in the specification etc. making holes including chasing in solid block / masonry walls with groove cutting machine to required width and depth, making holes in brick or RCC wall as per requirement ,clearing the debris, grouting of concealed pipes, making good the chase as mentioned, making good the wall and floors, making connection with down take to satisfaction of engineering in charge with proper care, protecting fittings & pipes till the final handing over etc. as directed by E-I-C complete as per specifications & drawing provided for all places, all heights & all levels.
SITC of 160 mm Low noise pipe with fittings Providing & Fixing of 160 mm dia Low noise pipe confirming to EN12056 with ring fit type including all fittings and accessories complete. The work including solvent jointing hydraulic testing the joints & pipes as mentioned in the specification etc. making holes including chasing in solid block / masonry walls with groove cutting machine to required width and depth, making holes in brick or RCC wall as per requirement ,clearing the debris, grouting of concealed pipes, making good the chase as mentioned, making good the wall and floors, making connection with down take to satisfaction of engineering in charge with proper care, protecting fittings & pipes till the final handing over etc. as directed by E-I-C complete as per specifications & drawing provided for all places, all heights & all levels.
SITC of 200 mm Low noise pipe with fittings Providing & Fixing of 200 mm dia Low noise pipe confirming to EN12056 with ring fit type including all fittings and accessories complete. The work including solvent jointing hydraulic testing the joints & pipes as mentioned in the specification etc. making holes including chasing in solid block / masonry walls with groove cutting machine to required width and depth, making holes in brick or RCC wall as per requirement ,clearing the debris, grouting of concealed pipes, making good the chase as mentioned, making good the wall and floors, making connection with down take to satisfaction of engineering in charge with proper care, protecting fittings & pipes till the final handing over etc. as directed by E-I-C complete as per specifications & drawing provided for all places, all heights & all levels.
SITC of 110 mm SWR PVC pipe with fittings Providing & Fixing of 110 mm dia 6 Kg/ sq. cm SWR TYPE A PVC Pipe ISI marked brand as per IS 13592 self fit type complete. The work including solvent jointing hydraulic testing the joints & pipes as mentioned in the specification etc. making holes including fixing on the wall with clamps and fasteners at 1.00 meter distance or as mentioned in the specifications, making holes in brick or RCC wall as per requirement, clearing the debris, grouting of concealed pipes, making good the chase as mentioned, making good the wall and floors, making connection with down take to satisfaction of engr / arch with proper care, protecting fittings & pipes till the final handing over etc. as directed by E-I-C complete as per specifications & drawing provided for all places, all heights & all levels (Exposed work on wall- Rain Water)
SITC of 160 mm SWR PVC pipe with fittings Providing & Fixing of 160 mm dia 6 Kg/ sq. cm SWR TYPE A PVC Pipe ISI marked brand as per IS 13592 self fit type complete. The work including solvent jointing hydraulic testing the joints & pipes as mentioned in the specification etc. making holes including fixing on the wall with clamps and fasteners at 1.00 meter distance or as mentioned in the specifications, making holes in brick or RCC wall as per requirement, clearing the debris, grouting of concealed pipes, making good the chase as mentioned, making good the wall and floors, making connection with down take to satisfaction of engr / arch with proper care, protecting fittings & pipes till the final handing over etc. as directed by E-I-C complete as per specifications & drawing provided for all places, all heights & all levels (Exposed work on wall- Rain Water)
P & F of 110 mm uPVC P-trap Providing and fixing uPVC Trap confirming to IS 14735, including cost of cutting and making good of wall and floors as per specification & to the satisfaction of Engineer-In-Charge. 110 mm P-trap (100 mm inlet & 75 mm outlet)
P & F SS316 Cockroach Trap with Grating Providing & fixing heavy quality SS 316 grade cockroach Trap with Grating over NT/P-trap/S-trap of approved design including setting in floor with white cement sand mortar 1:2 to match with floor finish to the satisfaction of arch /EiC with proper care) protecting fittings & pipes till the final handing over etc. as directed by E-1-C complete as per specifications & drawing provided at all places, all levels & all height CCT S 129 Square 129mm x 129 mm SS 316 grade of Chilly Make.
P & F 75 mm NB uPVC Nahni Trap Providing and fixing in position 75 mm N.B. uPVC Nahni trap of self cleansing design with 50 mm water seal conforming to IS:14735-90 complete with SS jali, making of opening in floor, marble / tiles, for fixing grating as per tender drawing.
P & F 75 mm NB uPVC Multi Floor Trap Providing and fixing in position 75 mm N.B. uPVC multi Floor trap of self cleansing design with 50 mm water seal conforming to IS:14735-90 complete with SS jali, making of opening in floor, marble / tiles, for fixing grating as per tender drawing.
900 x 800 x 600 mm Brick Masonry Manhole Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) withR.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (Medium duty) 500 mm Dia internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) with common burnt clay of class designation 5 as directed by E-I-C complete as per specifications & drawing provided for all places, all heights & all levels
1200 x 900 x 900 mm Brick Masonry Manhole Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) withR.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (Medium duty) 500 mm Dia internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) with common burnt clay of class designation 5 as directed by E-I-C complete as per specifications & drawing provided for all places, all heights & all levels
900 x 800 x 600 mm Manhole Extra Depth Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) withR.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 60 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) with common burnt clay of class designation 5 as directed by E-I-C complete as per specifications & drawing provided for all places, all heights & all levels. Extra Depth Beyond mentioned depth for above items Inside size 90x80 cm
1200 x 900 x 900 mm Manhole Extra Depth Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) withR.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (Medium duty) 500 mm Dia internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) with common burnt clay of class designation 5 as directed by E-I-C complete as per specifications & drawing provided for all places, all heights & all levels. Extra Depth Beyond mentioned depth for above items Inside size 120x90 cm
P & F 500 mm CI Cover with Frame Supplying and fixing C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not Jess than 116 kg (weight of cover 58 kg and weight of frame 58 kg).
P&L 250 mm NP3 RCC Pipe Providing and laying non-pressure NP3 class R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : (For Rain Water underground network) 250 mm dia. R.C.C. pipe
P&F MS Foot Rest Providing and fixing M.S. foot rests with 20x20 mm square bar including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design & to the satisfaction of Engineer Incharge.
500 x 450 x 600 mm Road Gully Chamber Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design with common burnt clay FPS (non modular) bricks of class designation 7.5 as directed by E-I-C complete as per specifications & drawing provided for all places, all heights & all levels.
SITC of Mud Pump 36 m3/hr & 25 m Head Supply, installation, testing and commissioning of submersible type OPEN WELL MUD PUMP having SS casing & body Dynamically Balanced AISI 304 stainless steel shaft running in ball bearing on both ends and protected by Bronze shaft sleeves. Pumps shall be fitted with mechanical seals, 2900 RPM, 415 volts, 50 cycles Ac 3 phase Motor should be rated for +/- 10% voltage fluctuation of standard 415 volts including all relevant accessories for complete installation and providing probe level control with cabling and should be oil/ water cooled, PLC panel for providing control on BMS with RS 485 port and should be modbus enabled etc. as per technical specification & direction of EIC. Capacity: 28 m3/hr & 25 m Head - Basement Sump (1W + 1S) Solid Handling: 10-12 mm
SITC of 75 mm uPVC pipe 10 kg/cm2 with fittings Supply, Installation, Testing and Commissioning of 75 mm dia PVC-U quickfit type Pipe conforming to IS:4985 class V (10 Kg/Sq.cm) including all moulding fittings such as tees, bends, reducers, coupling, adopters etc. solvent welded joint as per manufacturer recommendation including necessary clamps, tie rod, anchor fasteners etc. In case of requirement of structural steel supports/ excavation/ encasing, shall be paid separately.
SITC of 110 mm uPVC pipe 10 kg/cm2 with fittings Supply, Installation, Testing and Commissioning of 110 mm dia PVC-U quickfit type Pipe conforming to IS:4985 class V (10 Kg/Sq.cm) including all moulding fittings such as tees, bends, reducers, coupling, adopters etc. solvent welded joint as per manufacturer recommendation including necessary clamps, tie rod, anchor fasteners etc. In case of requirement of structural steel supports/ excavation/ encasing, shall be paid separately.
SITC of 160 mm uPVC pipe 10 kg/cm2 with fittings Supply, Installation, Testing and Commissioning of 160 mm dia PVC-U quickfit type Pipe conforming to IS:4985 class V (10 Kg/Sq.cm) including all moulding fittings such as tees, bends, reducers, coupling, adopters etc. solvent welded joint as per manufacturer recommendation including necessary clamps, tie rod, anchor fasteners etc. In case of requirement of structural steel supports/ excavation/ encasing, shall be paid separately.
SITC of GI Pipe 100 mm class 'C' Supply, installation, testing and commissioning of 100 mm dia GI Pipe class 'C' (heavy duty) including all accessories such as screwed / welded joints, flanges, tees, reducers, clamps etc. including lift to all heights, welding, jointing, painting and inserted rubber gaskets, nuts, bolts etc. as required. Pipes shall be painted with one coat of primer & two coats synthetic enamel paint. shall be fixed in ceiling, walls, columns for all heights with hangers and fasteners. In case of requirement of structural steel supports, shall be paid separately. (For Sump riser)
P&F CI Grating 150 x 150 x 6 mm (LxWxt) Providing and fixing of C.I. Grating 150 mm x 150 mm x 6 mm thick including all fitting and accessories, cutting and making good the walls complete (For Basement Drainage).
GI Puddle Flange 250 mm dia Supply, installation, testing & commissioning of GI Puddle Flages as per Standard drawings.
GI Puddle Flange 200 mm dia Supply, installation, testing & commissioning of GI Puddle Flages as per Standard drawings.
GI Puddle Flange 150 mm dia Supply, installation, testing & commissioning of GI Puddle Flages as per Standard drawings.
GI Puddle Flange 100 mm dia Supply, installation, testing & commissioning of GI Puddle Flages as per Standard drawings.
GI Puddle Flange 80 mm dia Supply, installation, testing & commissioning of GI Puddle Flages as per Standard drawings.
GI Puddle Flange 65 mm dia Supply, installation, testing & commissioning of GI Puddle Flages as per Standard drawings.
GI Puddle Flange 50 mm dia Supply, installation, testing & commissioning of GI Puddle Flages as per Standard drawings.
GI Puddle Flange 40 mm dia Supply, installation, testing & commissioning of GI Puddle Flages as per Standard drawings.
GI Puddle Flange 32 mm dia Supply, installation, testing & commissioning of GI Puddle Flages as per Standard drawings.
P&F CI Grating 600 mm x 300 mm x 25 mm (LxWxt) Providing and fixing 25mm thick C.I. heavy duty grating of below sizes fixed with 35X35X5 M.S. angle.
SITC of Hydropneumatic Pumping System 21 m3/hr & 18 m Head Supply, installation, testing & commissioning of Hydropneumatics system with vertical inline Multistage booster centrifugal SS pump-motor sets, balancing tank, mounting skid, foot valves, suction & delivery pipe, fittings, Y-strainer, valves. The scope shall also include pressure switches, level switches, level indicator, VFD based control panel with starters, protections, relays, cables, interlocking with level & pressure switches, Suction Delivery Piping all Connection, PLC panel for providing control on BMS with RS 485 port and should be modbus enabled etc. complete at terrace level as per technical specification and direction of EIC. Capacity : 21 m3/hr & 18 m Head - Domestic Water (1W+1S)
SITC of Hydropneumatic Pumping System 18 m3/hr & 18 m Head Supply, installation, testing & commissioning of Hydropneumatics system with vertical inline Multistage booster centrifugal SS pump-motor sets, balancing tank, mounting skid, foot valves, suction & delivery pipe, fittings, Y-strainer, valves. The scope shall also include pressure switches, level switches, level indicator, VFD based control panel with starters, protections, relays, cables, interlocking with level & pressure switches, Suction Delivery Piping all Connection, PLC panel for providing control on BMS with RS 485 port and should be modbus enabled etc. complete at terrace level as per technical specification & direction of EIC. Capacity : 18 m3/hr & 18 m Head - Flushing Water (1W+1S)
SITC of Hydropneumatic Pumping System 10 m3/hr & 18 m Head Supply, installation, testing & commissioning of Hydropneumatics system with vertical inline Multistage booster centrifugal SS pump-motor sets, balancing tank, mounting skid, foot valves, suction & delivery pipe, fittings, Y-strainer, valves. The scope shall also include pressure switches, level switches, level indicator, VFD based control panel with starters, protections, relays, cables, interlocking with level & pressure switches, Suction Delivery Piping all Connection, PLC panel for providing control on BMS with RS 485 port and should be modbus enabled etc. complete at terrace level as per technical specification & direction of EIC. Capacity : 10 m3/hr & 18 m Head - Irrigation (1W+1S)
33 kV GIS PANEL Supply, Installation, Testing and Commissioning of indoor type floor mounted 33 kV, Gas insulated Indoor switchgear - GIS Panel (top entry) with 2 I/C breaker, 1 EA B/C and 3 EA. O/G Breakers, totally enclosed fully interlocked breaker as per IEC62271-100, as amended up to date and additional specification, Panel shall have micro processor based numerical relay with O/L, S/C,E/F. The HT panel shall be compatible for SCADA/ BMS applications and shall be complete with compatible hardwares, all meters should be provided with RS 485 port with MODBUS, all feeder shall have capacitive voltage indicator, dummy plug for spare feeders, all complete work as oer soecification and drawing.
DRY TYPE TRANSFORMER Supplying, Installation, Testing, Commissioning of cast rasin "Dry type" 2000KVA, 33/0.415KV, indoor type, 3 phase, 50 Hz, vector group DYN 11, copper wound, Class F insulation, associates with winding temperature indicator /controller actuated by means of resistance temperature detector embedded in LV winding indoor type transformer with approximately 6.25% impedance with on load· tap changer+ Transformer mounted or to be install separately RTCC+ AVR. On load tap changer shall be Vacuum base . Tapping on HV side in step @ 2.5% with range of +10 to -10% voltage range. having cable End boxes on HV side suitable for 3 C x 300 M2m. XLPE cable on 33KV grade and LV side & 3200 Amp 4 Pole Sandwich Busduct connection ,suitably mounted on M.S.channel i/c supplying and grouting of suitably M.S.channel with all accessories and confirming to IS:11171:1985 & as per specification. Maximum losses shall confirm ECBC 2017@ 120 deg. all complete work as per specification and drawing. Transformer shall be designed and manufactured as per IEC 60076-1 and must be rated for Class F1 under fire behaviour. Complete in all respect as required at site. Transformer shall be compatible for SCADA/ BMS applications and shall be complete with compatible hardwares and all meters should be provided with RS 485 port with MODBUS, Follow GIFTCL Electrical ready reckoner guide line.
BUSDUCT 3200A Supplying, installation, testing and commissioning of IP 55 Sandwich Type busduct along with the required accessories. Integral Four pole and Integral Earth busbar, 415 volts,50 Hz, AC, rated insulation voltage - 1000V class-F, impulse withstandd voltage-12KV, 50Hz A.C. Whole internal conductors (phase and neutral) should be 4 EA aluminium with 5 stage galvanic process. Busduct should having 2 EA. integral earth bar throughout length. aluminium bus bars having current density of 130 A / sq cm at nominal current rating. Conductor should embedded in an epoxy loaded resin combination which is the external structure of the busbar IP-55 rating complete. All necessary joints, elbow joints & expansion joints and bends, Phase change over , Expansion joints,Vertical / horizontal supports,Thrust pad, adopter box, fire barriers, and copper flexible for joints should be in scope. Indian standard should comply IEC 61439-6. Complete in all respect as per the requirement.product should comply seismic zone 3 requirement and shall submit test report for that. 3200 A IP54 75kA SC for 1 sec
Supplying, installation, testing and commissioning of IP 55 Sandwich Type Rising Mains along with the required accessories. Integral Four pole and Integral Earth busbar, 415 volts,50 Hz, AC, rated insulation voltage - 1000V class-F, impulse withstandd voltage-12KV, 50Hz A.C. Whole internal conductors (phase and neutral) should be 4 EA aluminium with 5 stage galvanic process. Busduct should having 2 EA. integral earth bar throughout length. aluminium bus bars having current density of 130 A / sq cm at nominal current rating. Conductor should embedded in an epoxy loaded resin combination which is the external structure of the busbar IP-55 rating complete. All necessary joints, elbow joints & expansion joints and bends, Phase change over , Expansion joints,Vertical / horizontal supports,Thrust pad, adopter box, fire barriers, and copper flexible for joints should be in scope. Indian standard should comply IEC 61439-6. Complete in all respect as per the requirement.product should comply seismic zone 3 requirement and shall submit test report for that. 3200A TP+N+100%PE - Not less than 65 KA for 1 Sec
Supplying, installation, testing and commissioning of IP 55 Sandwich Type Rising Mains along with the required accessories. Integral Four pole and Integral Earth busbar, 415 volts,50 Hz, AC, rated insulation voltage - 1000V class-F, impulse withstandd voltage-12KV, 50Hz A.C. Whole internal conductors (phase and neutral) should be 4 EA aluminium with 5 stage galvanic process. Busduct should having 2 EA. integral earth bar throughout length. aluminium bus bars having current density of 130 A / sq cm at nominal current rating. Conductor should embedded in an epoxy loaded resin combination which is the external structure of the busbar IP-55 rating complete. All necessary joints, elbow joints & expansion joints and bends, Phase change over , Expansion joints,Vertical / horizontal supports,Thrust pad, adopter box, fire barriers, and copper flexible for joints should be in scope. Indian standard should comply IEC 61439-6. Complete in all respect as per the requirement.product should comply seismic zone 3 requirement and shall submit test report for that. 2500A TP+N+100%PE - Not less than 50 KA for 1 Sec
Supplying, installation, testing and commissioning of IP 55 Sandwich Type Rising Mains along with the required accessories. Integral Four pole and Integral Earth busbar, 415 volts,50 Hz, AC, rated insulation voltage - 1000V class-F, impulse withstandd voltage-12KV, 50Hz A.C. Whole internal conductors (phase and neutral) should be 4 EA aluminium with 5 stage galvanic process. Busduct should having 2 EA. integral earth bar throughout length. aluminium bus bars having current density of 130 A / sq cm at nominal current rating. Conductor should embedded in an epoxy loaded resin combination which is the external structure of the busbar IP-55 rating complete. All necessary joints, elbow joints & expansion joints and bends, Phase change over , Expansion joints,Vertical / horizontal supports,Thrust pad, adopter box, fire barriers, and copper flexible for joints should be in scope. Indian standard should comply IEC 61439-6. Complete in all respect as per the requirement.product should comply seismic zone 3 requirement and shall submit test report for that. 2000A TP+N+100%PE - Not less than 50 KA for 1 Sec
Supplying, installation, testing and commissioning of IP 55 Sandwich Type Rising Mains along with the required accessories. Integral Four pole and Integral Earth busbar, 415 volts,50 Hz, AC, rated insulation voltage - 1000V class-F, impulse withstandd voltage-12KV, 50Hz A.C. Whole internal conductors (phase and neutral) should be 4 EA aluminium with 5 stage galvanic process. Busduct should having 2 EA. integral earth bar throughout length. aluminium bus bars having current density of 130 A / sq cm at nominal current rating. Conductor should embedded in an epoxy loaded resin combination which is the external structure of the busbar IP-55 rating complete. All necessary joints, elbow joints & expansion joints and bends, Phase change over , Expansion joints,Vertical / horizontal supports,Thrust pad, adopter box, fire barriers, and copper flexible for joints should be in scope. Indian standard should comply IEC 61439-6. Complete in all respect as per the requirement.product should comply seismic zone 3 requirement and shall submit test report for that. 1600A TP+N+100%PE - Not less than 50 KA for 1 Sec
Supplying, installation, testing and commissioning of IP 55 Sandwich Type Rising Mains along with the required accessories. Integral Four pole and Integral Earth busbar, 415 volts,50 Hz, AC, rated insulation voltage - 1000V class-F, impulse withstandd voltage-12KV, 50Hz A.C. Whole internal conductors (phase and neutral) should be 4 EA aluminium with 5 stage galvanic process. Busduct should having 2 EA. integral earth bar throughout length. aluminium bus bars having current density of 130 A / sq cm at nominal current rating. Conductor should embedded in an epoxy loaded resin combination which is the external structure of the busbar IP-55 rating complete. All necessary joints, elbow joints & expansion joints and bends, Phase change over , Expansion joints,Vertical / horizontal supports,Thrust pad, adopter box, fire barriers, and copper flexible for joints should be in scope. Indian standard should comply IEC 61439-6. Complete in all respect as per the requirement.product should comply seismic zone 3 requirement and shall submit test report for that. 1000A TP+N+100%PE - Not less than 50 KA for 1 Sec
Supplying, installation, testing and commissioning of IP 55 Sandwich Type Rising Mains along with the required accessories. Integral Four pole and Integral Earth busbar, 415 volts,50 Hz, AC, rated insulation voltage - 1000V class-F, impulse withstandd voltage-12KV, 50Hz A.C. Whole internal conductors (phase and neutral) should be 4 EA aluminium with 5 stage galvanic process. Busduct should having 2 EA. integral earth bar throughout length. aluminium bus bars having current density of 130 A / sq cm at nominal current rating. Conductor should embedded in an epoxy loaded resin combination which is the external structure of the busbar IP-55 rating complete. All necessary joints, elbow joints & expansion joints and bends, Phase change over , Expansion joints,Vertical / horizontal supports,Thrust pad, adopter box, fire barriers, and copper flexible for joints should be in scope. Indian standard should comply IEC 61439-6. Complete in all respect as per the requirement.product should comply seismic zone 3 requirement and shall submit test report for that. 400A TP+N+100%PE - Not less than 50 KA for 1 Sec
Plug in BOX For Sandwich compact Rising Mains Plug tap off BoxPlug in BOX for Aluminum Air Insulated compact Rising Mains: Supplying , installing , testing and commissioning of Plug In/ Tap Off Box suitable for the following capacity of MCCB ( All Ics-100% Icu) & MCB , C curve 10kA. All the tap off boxes can be fitted and removed without disconnecting the power from the bus bar. The cover can only be opened when the box is correctly installed and with the protection switch in the off position, thus ensuring the absence of the load for safety of human while assembly & disassmbly (boxes are equipped with an isolating device integral with the cover.) necessary arrangement for outgoing cable termination, earthing etc 6 to 32 A FP MCCB 36 kA with Plug in tap off Box
Plug tap off BoxPlug in BOX for Aluminum Air Insulated compact Rising Mains: Supplying , installing , testing and commissioning of Plug In/ Tap Off Box suitable for the following capacity of MCCB ( All Ics-100% Icu) & MCB , C curve 10kA. All the tap off boxes can be fitted and removed without disconnecting the power from the bus bar. The cover can only be opened when the box is correctly installed and with the protection switch in the off position, thus ensuring the absence of the load for safety of human while assembly & disassmbly (boxes are equipped with an isolating device integral with the cover.) necessary arrangement for outgoing cable termination, earthing etc 6 to 32A DP MCCB 36 kA with Plug in tap off Box
Plug tap off BoxPlug in BOX for Aluminum Air Insulated compact Rising Mains: Supplying , installing , testing and commissioning of Plug In/ Tap Off Box suitable for the following capacity of MCCB ( All Ics-100% Icu) & MCB , C curve 10kA. All the tap off boxes can be fitted and removed without disconnecting the power from the bus bar. The cover can only be opened when the box is correctly installed and with the protection switch in the off position, thus ensuring the absence of the load for safety of human while assembly & disassmbly (boxes are equipped with an isolating device integral with the cover.) necessary arrangement for outgoing cable termination, earthing etc 40 A FP MCCB 36 kA with Plug in tap off Box
Plug tap off BoxPlug in BOX for Aluminum Air Insulated compact Rising Mains: Supplying , installing , testing and commissioning of Plug In/ Tap Off Box suitable for the following capacity of MCCB ( All Ics-100% Icu) & MCB , C curve 10kA. All the tap off boxes can be fitted and removed without disconnecting the power from the bus bar. The cover can only be opened when the box is correctly installed and with the protection switch in the off position, thus ensuring the absence of the load for safety of human while assembly & disassmbly (boxes are equipped with an isolating device integral with the cover.) necessary arrangement for outgoing cable termination, earthing etc 63 A FP MCCB , 36kA with Plug in tap off Box
Plug tap off BoxPlug in BOX for Aluminum Air Insulated compact Rising Mains: Supplying , installing , testing and commissioning of Plug In/ Tap Off Box suitable for the following capacity of MCCB ( All Ics-100% Icu) & MCB , C curve 10kA. All the tap off boxes can be fitted and removed without disconnecting the power from the bus bar. The cover can only be opened when the box is correctly installed and with the protection switch in the off position, thus ensuring the absence of the load for safety of human while assembly & disassmbly (boxes are equipped with an isolating device integral with the cover.) necessary arrangement for outgoing cable termination, earthing etc 125 A MCCB FP, 36kA with Plug in tap off Box
Plug tap off BoxPlug in BOX for Aluminum Air Insulated compact Rising Mains: Supplying , installing , testing and commissioning of Plug In/ Tap Off Box suitable for the following capacity of MCCB ( All Ics-100% Icu) & MCB , C curve 10kA. All the tap off boxes can be fitted and removed without disconnecting the power from the bus bar. The cover can only be opened when the box is correctly installed and with the protection switch in the off position, thus ensuring the absence of the load for safety of human while assembly & disassmbly (boxes are equipped with an isolating device integral with the cover.) necessary arrangement for outgoing cable termination, earthing etc 160 A MCCB FP, 36kA with Plug in tap off Box
Plug tap off BoxPlug in BOX for Aluminum Air Insulated compact Rising Mains: Supplying , installing , testing and commissioning of Plug In/ Tap Off Box suitable for the following capacity of MCCB ( All Ics-100% Icu) & MCB , C curve 10kA. All the tap off boxes can be fitted and removed without disconnecting the power from the bus bar. The cover can only be opened when the box is correctly installed and with the protection switch in the off position, thus ensuring the absence of the load for safety of human while assembly & disassmbly (boxes are equipped with an isolating device integral with the cover.) necessary arrangement for outgoing cable termination, earthing etc 250 A MCCB FP, 36kA with Plug in tap off Box
Plug tap off BoxPlug in BOX for Aluminum Air Insulated compact Rising Mains: Supplying , installing , testing and commissioning of Plug In/ Tap Off Box suitable for the following capacity of MCCB ( All Ics-100% Icu) & MCB , C curve 10kA. All the tap off boxes can be fitted and removed without disconnecting the power from the bus bar. The cover can only be opened when the box is correctly installed and with the protection switch in the off position, thus ensuring the absence of the load for safety of human while assembly & disassmbly (boxes are equipped with an isolating device integral with the cover.) necessary arrangement for outgoing cable termination, earthing etc 400 A MCCB FP, 36kA with Plug in tap off Box
Plug tap off BoxPlug in BOX for Aluminum Air Insulated compact Rising Mains: Supplying , installing , testing and commissioning of Plug In/ Tap Off Box suitable for the following capacity of MCCB ( All Ics-100% Icu) & MCB , C curve 10kA. All the tap off boxes can be fitted and removed without disconnecting the power from the bus bar. The cover can only be opened when the box is correctly installed and with the protection switch in the off position, thus ensuring the absence of the load for safety of human while assembly & disassmbly (boxes are equipped with an isolating device integral with the cover.) necessary arrangement for outgoing cable termination, earthing etc 400 A MCCB FP, 36kA with Plug in tap off Box
Plug tap off BoxPlug in BOX for Aluminum Air Insulated compact Rising Mains: Supplying , installing , testing and commissioning of Plug In/ Tap Off Box suitable for the following capacity of MCCB ( All Ics-100% Icu) & MCB , C curve 10kA. All the tap off boxes can be fitted and removed without disconnecting the power from the bus bar. The cover can only be opened when the box is correctly installed and with the protection switch in the off position, thus ensuring the absence of the load for safety of human while assembly & disassmbly (boxes are equipped with an isolating device integral with the cover.) necessary arrangement for outgoing cable termination, earthing etc 800 A MCCB FP, 36kA with Plug in tap off Box
MCCB End feed unitPlug in BOX for Aluminum Air Insulated compact Rising Mains: Supplying , installing , testing and commissioning of Plug In/ Tap Off Box suitable for the following capacity of MCCB ( All Ics-100% Icu) & MCB , C curve 10kA. All the tap off boxes can be fitted and removed without disconnecting the power from the bus bar. The cover can only be opened when the box is correctly installed and with the protection switch in the off position, thus ensuring the absence of the load for safety of human while assembly & disassmbly (boxes are equipped with an isolating device integral with the cover.) necessary arrangement for outgoing cable termination, earthing etc 1000A FP ACB 36KA With End feed unit
MCCB End feed unitPlug in BOX for Aluminum Air Insulated compact Rising Mains: Supplying , installing , testing and commissioning of Plug In/ Tap Off Box suitable for the following capacity of MCCB ( All Ics-100% Icu) & MCB , C curve 10kA. All the tap off boxes can be fitted and removed without disconnecting the power from the bus bar. The cover can only be opened when the box is correctly installed and with the protection switch in the off position, thus ensuring the absence of the load for safety of human while assembly & disassmbly (boxes are equipped with an isolating device integral with the cover.) necessary arrangement for outgoing cable termination, earthing etc 400A FP MCCB 36KA With End feed unit
MCCB End feed unitPlug in BOX for Aluminum Air Insulated compact Rising Mains: Supplying , installing , testing and commissioning of Plug In/ Tap Off Box suitable for the following capacity of MCCB ( All Ics-100% Icu) & MCB , C curve 10kA. All the tap off boxes can be fitted and removed without disconnecting the power from the bus bar. The cover can only be opened when the box is correctly installed and with the protection switch in the off position, thus ensuring the absence of the load for safety of human while assembly & disassmbly (boxes are equipped with an isolating device integral with the cover.) necessary arrangement for outgoing cable termination, earthing etc 800A FP ACB 36KA With End feed unit
SUBSTATION EQUIPMENT & SUBSTATION AUXILIARY Cable 33kV 300 M2mSITC of 33 KV, 3 core Al. 300 M2m H.T. XLPE armoured cable. Supply, Installation, testing and commissioning of 33 kV 3C 300 M2m AL Arcable cable in vertical duct/ cable trench/ cable tray including cable tagging, tie, route survey, core cutting, sealing of opening, preparation of as built drawing, etc. all complete work as per specifications.
Supply, Installation, Testing & Commissioning of indoor termination suitable for 33 kV GIS panel of 33KV 300 sqmm 3C Al. Ar. XLPE insulated cables including required cable support structure, sealing, glanding all complete works as per specification.
AIS Termination 33 kVSupply, Installation, Testing & Commissioning of H.T. cable indoor type end connection for 33 KV XLPE, 300 sq mm x 3 core cable including required cable support structure, sealing, glanding all complete works as per specification.
CO2 fire extinguishers 4.5 kgSupplying & Erecting conventional type Carbon Dioxide fire extinguishers of ISI approved of 4.5 kgs including required support structure, glanding all complete works as per specification.
CO2 fire extinguishers 6.5 kgSupplying & Erecting conventional type Carbon Dioxide fire extinguishers of ISI approved of 6.5 kgs including required support structure, glanding all complete works as per specification.
Emergency light 20WSuppplying & Erecting automatic emergency light with maintenance free battery for 20 watts tube. With battery and provision for grid power with required support structure, all complete works as per specification.
Rubber mat 1.1 kVSupplying & Erecting Rubber mat 1.1 KV grade ISI marked 1000 x 2000 x 4 mm size as per IS:15652/IEC 61111
Rubber mat 33 kVSupplying & Erecting Rubber mat 33 KV grade ISI marked 1000 x 2000 x 12 mm size as per IS:15652/IEC 61111
Danger board for medium voltageProviding and erecting danger notice board for medium voltage installation to be erected as per I.S. The board should be 150 x 150 mm.
Providing and erecting danger notice board for high voltage installation to be erected as per I.S.
Providing printed instruction chart both in English & REGIONAL LANGUAGE & duly framed out on glass for treatment of person suffering from Electric shock.
Providing pair of rubber hand gloves suitable for working on 33 KV supply.
Supplying Standard First aid box with all the Standard contents.
Supplying GI bucket round bottom duly painted 9 Ltrs. capacity & filled with dry sand & kept on stand provided on stand or wall hook.
Supplying & Erecting 1.5 mtr. (5') x 0.9 mtr. (3.1') x 0.6 mtr. (2.1') Floor mounted stand (For keeping 4 Nos.of buckets) made of 30 x 30 x 4 mm. angle iron welded with 4 hooks and duly painted with one coat of red lead & two coats of Approved enameled silver paints.
Wall hooks of 22 to 25 cms. projection for keeping fire buckets made out of 15 mm. dia M.S. rod grouted in wall to a depth of minimum 15 cms.
MAIN LT PANEL : Common Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
FLOOR PANEL 1 Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
FLOOR PANEL 2 Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
EMERGENCY PANEL (ESSENTIAL PANEL) Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
FLOOR PANEL 3 Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
NON ESSENTIAL PANEL Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
FLOOR PANEL 4 Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
1st BASEMENT VENTILATIN PANEL Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
PLUMBING PANEL Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
TERRACE PLUMBING PANEL Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
2nd BASEMENT VENTILATIN PANEL Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
LIFT Panel Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
3rd BASEMENT VENTILATIN PANEL Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
Pressurisation System Panel Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
ATS PANEL TYPE 1 Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
ATS PANEL TYPE 2 Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
ATS PANEL TYPE 3 Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
ATS PANEL TYPE 4 Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
UPS Panel Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
4th BASEMENT VENTILATIN PANEL Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
External Lighting Panel (Typical for Façade Lighting panel) Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
PLANT ROOM PANEL Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
STACK PARKING PANEL Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
500 KVAR RTPFCR Panel Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
EV CAR Charging Panel Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification.Necessory interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
Auto transfer Switch with enclosure Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of 125A Autotransfer Switch with enclosure board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings & Specification. Necessary interlocking to be carried out as per attached SLD (Single Line Diagram) with required support structure, frame, accessories all complete work.
DISTRIBUTION BOARD All rates quoted shall be inclusive of cutting in wall , / zari work / chazzing in walls for installation of DBs for making good the same with cement mortar appropriate mix and strength as directed by the Project Manager.In db wiring phase tagging required. The rate shall be including of fixing Wiring chart/SLD inside DB as per instruction & approval by Client PM's. 12 WAY TPN Distribution Board: Supplying, erecting, testing and commissioning of only TPN D.B. with space for FPMCB as incoming and space for DPELMCB and 10 SPMCB as outgoing per phase (i.e. 12 way TPN D.B.) with 12 way PPI kit cat
8 WAY TPN Distribution BoardTPN Distribution Board Supplying, erecting, testing and commissioning of only TPN D.B. with space for FPMCB as incoming and space for DPELMCB and 6 SPMCB as outgoing per phase (i.e. 8 way TPN D.B.) with 8 way PPI kit cat
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, PPI kit, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (8 + 18), Double door
SPN Distribution Board Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16 way, Double door
Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door
Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door
VTPN Distribution Board Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way (4 + 36), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door
Supplying,erecting, testing and commissioning of 8 Way VTPN D.B having suitable space for up to 32 A FP MCB as incomer and 8 TP MCBs as outgoing.
Supplying,erecting, testing and commissioning of 4 Way VTPN D.B having suitable space for up to 32 A FP MCB as incomer and 4 TP / 12SP MCBs as outgoing.
Supplying and fixing single pole 6A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing Double pole 6A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
6 to 32 A DP RCCB (30mA) MCB s and its Accessories Supplying, Assembling, levelling, connecting & testing following MCB / ELMCB / MCCB etc in TPN Distribution boards as specified 6 to 32 A DP RCCB (30mA)
40A DP RCCB (30mA) MCB s and its Accessories Supplying, Assembling, levelling, connecting & testing following MCB / ELMCB / MCCB etc in TPN Distribution boards as specified 40 A DP RCCB (30mA) 40 A DP RCCB (30mA)
40 A FP MCB MCB s and its Accessories Supplying, Assembling, levelling, connecting & testing following MCB / ELMCB / MCCB etc in TPN Distribution boards as specified 40 A FP MCB
63 A FP MCB MCB s and its Accessories Supplying, Assembling, levelling, connecting & testing following MCB / ELMCB / MCCB etc in TPN Distribution boards as specified 63 A FP MCB
Blank Plates for DBMCB s and its Accessories Supplying, Assembling, levelling, connecting & testing following MCB / ELMCB / MCCB etc in TPN Distribution boards as specified Blank Plates
steel metal enclouser for FP MCB MCB s and its Accessories Supplying, Assembling, levelling, connecting & testing following MCB / ELMCB / MCCB etc in TPN Distribution boards as specified Sheet steel metal enclouser for FP MCB
MCCB Thermal & magnetic ReleaseMCCBs: Supplying, Assembling, levelling, connecting & testing following MCCB with enclosure. 32 A FP MCB not less than 16 KA Adjustable Thermal & magnetic Release and 125 A FP MCCB not less than 25 KA Adjustable Thermal & magnetic Release
Caution Board Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Caution boards of size 100 x 100 mm. to be supplied & fixed on the D.B.
LT CABLES 400 Sq.mm x 4C Al. Arm XLPE Cable Supply, testing and Laying XLPE steel wire/flat armoured cable of 1100 V grade FRLS of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or required cable support structure, core cutting, sealing or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support with required support as per specification all complete work. 400 Sq.mm x 3.5C Al. Arm Cable
Supply, testing and Laying XLPE steel wire/flat armoured cable of 1100 V grade FRLS of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or required cable support structure, core cutting, sealing or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support with required support as per specification all complete work. 300 Sq.mm x 3.5C Al. Arm Cable
Supply, testing and Laying XLPE steel wire/flat armoured cable of 1100 V grade FRLS of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or required cable support structure, core cutting, sealing or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support with required support as per specification all complete work. 240 Sq.mm x 3.5C Al. Arm Cable
Supply, testing and Laying XLPE steel wire/flat armoured cable of 1100 V grade FRLS of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or required cable support structure, core cutting, sealing or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support with required support as per specification all complete work. 185 Sq.mm x 3.5C Al. Arm Cable
Supply, testing and Laying XLPE steel wire/flat armoured cable of 1100 V grade FRLS of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or required cable support structure, core cutting, sealing or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support with required support as per specification all complete work. 150 Sq.mm x 3.5C Al. Arm Cable
Supply, testing and Laying XLPE steel wire/flat armoured cable of 1100 V grade FRLS of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or required cable support structure, core cutting, sealing or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support with required support as per specification all complete work. 120 Sq.mm x 3.5C Al. Arm Cable
Supply, testing and Laying XLPE steel wire/flat armoured cable of 1100 V grade FRLS of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or required cable support structure, core cutting, sealing or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support with required support as per specification all complete work. 95 Sq.mm x 3.5C Al. Arm Cable
Supply, testing and Laying XLPE steel wire/flat armoured cable of 1100 V grade FRLS of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or required cable support structure, core cutting, sealing or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support with required support as per specification all complete work. 70 Sq.mm x 3.5C Al. Arm Cable
Supply, testing and Laying XLPE steel wire/flat armoured cable of 1100 V grade FRLS of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or required cable support structure, core cutting, sealing or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support with required support as per specification all complete work. 50 Sq.mm x 3.5C Al. Arm Cable
Supply, testing and Laying XLPE steel wire/flat armoured cable of 1100 V grade FRLS of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or required cable support structure, core cutting, sealing or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support with required support as per specification all complete work. 35 Sq.mm x 3.5C Al. Arm Cable
Supply, testing and Laying XLPE steel wire/flat armoured cable of 1100 V grade FRLS of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or required cable support structure, core cutting, sealing or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support with required support as per specification all complete work. 25 Sq.mm x 4C Al. Arm Cable
Supply, testing and Laying XLPE steel wire/flat armoured cable of 1100 V grade FRLS of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or required cable support structure, core cutting, sealing or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support with required support as per specification all complete work. 16 Sq.mm x 4C Al. Arm Cable
Supply, testing and Laying XLPE steel wire/flat armoured cable of 1100 V grade FRLS of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or required cable support structure, core cutting, sealing or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support with required support as per specification all complete work. 10 Sq.mm x 4C Al. Arm Cable
Supply, testing and Laying XLPE steel wire/flat armoured cable of 1100 V grade FRLS of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or required cable support structure, core cutting, sealing or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support with required support as per specification all complete work. 16 Sq.mm x 3c Al. Arm Cable
Supply, testing and Laying XLPE steel wire/flat armoured cable of 1100 V grade FRLS of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or required cable support structure, core cutting, sealing or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support with required support as per specification all complete work. 10 Sq.mm x 3c Al. Arm Cable
Supply, testing and Laying XLPE steel wire/flat armoured cable of 1100 V grade FRLS of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or required cable support structure, core cutting, sealing or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support with required support as per specification all complete work. Copper Cables 6 Sq.mm x 4c cu. Arm Cable
Supply, testing and Laying XLPE steel wire/flat armoured cable of 1100 V grade FRLS of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or required cable support structure, core cutting, sealing or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support with required support as per specification all complete work. Copper Cables 4 Sq.mm x 4c cu. Arm Cable
Supply, testing and Laying XLPE steel wire/flat armoured cable of 1100 V grade FRLS of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or required cable support structure, core cutting, sealing or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support with required support as per specification all complete work. Copper Cables 2.5 Sq.mm x 4c cu. Arm Cable
Supply, testing and Laying XLPE steel wire/flat armoured cable of 1100 V grade FRLS of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or required cable support structure, core cutting, sealing or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support with required support as per specification all complete work. Copper Cables 1.5 Sq.mm x 4c cu. Arm Cable
Supply, testing and Laying XLPE steel wire/flat armoured cable of 1100 V grade FRLS of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or required cable support structure, core cutting, sealing or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support with required support as per specification all complete work. Copper Cables 6 Sq.mm x 3c cu. Arm Cable
Supply, testing and Laying XLPE steel wire/flat armoured cable of 1100 V grade FRLS of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or required cable support structure, core cutting, sealing or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support with required support as per specification all complete work. Copper Cables 4 Sq.mm x 3c cu. Arm Cable
Supply, testing and Laying XLPE steel wire/flat armoured cable of 1100 V grade FRLS of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or required cable support structure, core cutting, sealing or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support with required support as per specification all complete work. Copper Cables 2.5 Sq.mm x 3c cu. Arm Cable
Supply, testing and Laying XLPE steel wire/flat armoured cable of 1100 V grade FRLS of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or required cable support structure, core cutting, sealing or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support with required support as per specification all complete work. Copper Cables 1.5 Sq.mm x 3c cu. Arm Cable
Supply, testing and Laying of 240sqmmx3.5c cu fire surival cable
Supply, testing and Laying of 120sqmmx3.5c cu fire surival cable
Supply, testing and Laying of 16sqmmx3c cu fire surival cable
Supply, testing and Laying of 6sqmmx3c cu fire surival cable
HEAT / FIRE RESISTANT COATING OF CABLE SITC of intumescent based coating CP 678 on cables/bunch cables & cable tray for at least 1 mtr in every 14 mtrs for horizontal runs and to entire length of vertical runs . The coating shall have a density in the range of 1.2 to 1.4 Kg/ L. The coating shall be non-toxic, asbestos and halogen free and shall have good mechanical strength. The coating shall comply with IEC 332 part 3 (1992). The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96. The product should have a VOC content of approx. 60 g/l as per LEED 2009 and should not have any de-rating effect on the cable. Manufacturer should submitt relevant certificates for mentioned attributes. Coating shall be carried out by approved machine spraying system which will yield uniform thickness & better finish. Firestop installation shall be done by Hilti Accredited Firestop Speciality Contractor (HAFSC) and in accordance with guidelines . Firestop Speciality Contractor needs to submitt work completition certificate along with installation report through Hilti documentation Software CFS DM for periodic inspection & maintenance purpose.
CABLE TERMINATION supply, installation, testing and commissioing of cable termination with Double compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 400 Sq.mm x 3.5C Al. Arm Cable
supply, installation, testing and commissioing of cable termination with Double compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 300 Sq.mm x 3.5C Al. Arm Cable
supply, installation, testing and commissioing of cable termination with Double compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 240 Sq.mm x 3.5C Al. Arm Cable
supply, installation, testing and commissioing of cable termination with Double compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 185 Sq.mm x 3.5C Al. Arm Cable
supply, installation, testing and commissioing of cable termination with Double compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 150 Sq.mm x 3.5C Al. Arm Cable
supply, installation, testing and commissioing of cable termination with Double compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 120 Sq.mm x 3.5C Al. Arm Cable
supply, installation, testing and commissioing of cable termination with Double compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 95 Sq.mm x 3.5C Al. Arm Cable
supply, installation, testing and commissioing of cable termination with Double compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 70 Sq.mm x 3.5C Al. Arm Cable
supply, installation, testing and commissioing of cable termination with Double compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 50 Sq.mm x 3.5C Al. Arm Cable
supply, installation, testing and commissioing of cable termination with Double compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 35 Sq.mm x 3.5C Al. Arm Cable
supply, installation, testing and commissioing of cable termination with Double compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 25 Sq.mm x 4C Al. Arm Cable
supply, installation, testing and commissioing of cable termination with Double compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 16 Sq.mm x 4C Al. Arm Cable
supply, installation, testing and commissioing of cable termination with Double compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 10 Sq.mm x 4C Al. Arm Cable
supply, installation, testing and commissioing of cable termination with Double compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 16 Sq.mm x 3c Al. Arm Cable
supply, installation, testing and commissioing of cable termination with Double compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 10 Sq.mm x 3c Al. Arm Cable
supply, installation, testing and commissioing of cable termination with Double compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: Copper Cables : 6 Sq.mm x 4c Cu. Cable
supply, installation, testing and commissioing of cable termination with Double compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: Copper Cables : 4 Sq.mm x 4c Cu. Cable
supply, installation, testing and commissioing of cable termination with Double compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: Copper Cables : 2.5 Sq.mm x 4c Cu. Cable
supply, installation, testing and commissioing of cable termination with Double compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: Copper Cables : 1.5 Sq.mm x 4c Cu. Cable
supply, installation, testing and commissioing of cable termination with Double compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: Copper Cables : 6 Sq.mm x 3c Cu. Cable
supply, installation, testing and commissioing of cable termination with Double compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: Copper Cables : 4 Sq.mm x 3c Cu. Cable
supply, installation, testing and commissioing of cable termination with Double compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: Copper Cables : 2.5 Sq.mm x 3c Cu. Cable
supply, installation, testing and commissioing of cable termination with Double compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: Copper Cables : 1.5 Sq.mm x 3c Cu. Cable
GI LADDER TYPE Cable TraysCABLE TRAY Supply, installation, Erection, Testing and Commissioning hot dip GI LADDER TYPE Cable Trays with accessories such as coupling plates, bends, tees, reducers, coupling nut-bolts etc. along with necessary supporting frame, members, angles, clamps etc. of following width. The cost of installation shall include connection, bolting, cutting, etc. with required cable tray support and threaded rod, anchors, etc.as per specification and drawings complete with all required hardware: Supply, Installation, laying and connection of G.I. Ladder type cable tray with bends, tees, clamps and couplers for fixing of cable, cable tie, anchor fastener. The job also includes to paint the structure with two coats of red oxide and two coats color of enamel paint as approved . All material shall be Hot dip galvanised as per IS - 86 micron (630 g/m2) and specifications. The structural steel supports for the trays are to be provided minimum at every 1Mtr distance as per technical specifications. Standard length of cable tray shall be 3 meters. Cost including GI angle as per site requirements, Fabrication of supports, Painting of supports by two coats of red oxide followed by two coats of enamel paint, Installation of steel supports including using of fasteners, hardware as per drawings, specification, instruction of Engineer-in-charge. 1) Rate Quoted shall include cold galvanizing paint on welded spots. 2) Rate Quoted shall include site fabrication of required Bends, T-Junction, Elbows, X-Junction, Z-Sections, Reducer etc. and all reauired supporting strcture (G.I angle,G.I Base Angle,G.I Plate at ceiling for fixing of cable tray support including anchor fastner etc) and necessary accesories to comlete the cable tray hanging job 1000 x 100 made out of 2 mm thick
GI LADDER TYPE Cable TraysCABLE TRAY Supply, installation, Erection, Testing and Commissioning hot dip GI LADDER TYPE Cable Trays with accessories such as coupling plates, bends, tees, reducers, coupling nut-bolts etc. along with necessary supporting frame, members, angles, clamps etc. of following width. The cost of installation shall include connection, bolting, cutting, etc. with required cable tray support and threaded rod, anchors, etc.as per specification and drawings complete with all required hardware: Supply, Installation, laying and connection of G.I. Ladder type cable tray with bends, tees, clamps and couplers for fixing of cable, cable tie, anchor fastener. The job also includes to paint the structure with two coats of red oxide and two coats color of enamel paint as approved . All material shall be Hot dip galvanised as per IS - 86 micron (630 g/m2) and specifications. The structural steel supports for the trays are to be provided minimum at every 1Mtr distance as per technical specifications. Standard length of cable tray shall be 3 meters. Cost including GI angle as per site requirements, Fabrication of supports, Painting of supports by two coats of red oxide followed by two coats of enamel paint, Installation of steel supports including using of fasteners, hardware as per drawings, specification, instruction of Engineer-in-charge. 1) Rate Quoted shall include cold galvanizing paint on welded spots. 2) Rate Quoted shall include site fabrication of required Bends, T-Junction, Elbows, X-Junction, Z-Sections, Reducer etc. and all reauired supporting strcture (G.I angle,G.I Base Angle,G.I Plate at ceiling for fixing of cable tray support including anchor fastner etc) and necessary accesories to comlete the cable tray hanging job 750 x 100 made out of 2 mm thick
GI LADDER TYPE Cable TraysCABLE TRAY Supply, installation, Erection, Testing and Commissioning hot dip GI LADDER TYPE Cable Trays with accessories such as coupling plates, bends, tees, reducers, coupling nut-bolts etc. along with necessary supporting frame, members, angles, clamps etc. of following width. The cost of installation shall include connection, bolting, cutting, etc. with required cable tray support and threaded rod, anchors, etc.as per specification and drawings complete with all required hardware: Supply, Installation, laying and connection of G.I. Ladder type cable tray with bends, tees, clamps and couplers for fixing of cable, cable tie, anchor fastener. The job also includes to paint the structure with two coats of red oxide and two coats color of enamel paint as approved . All material shall be Hot dip galvanised as per IS - 86 micron (630 g/m2) and specifications. The structural steel supports for the trays are to be provided minimum at every 1Mtr distance as per technical specifications. Standard length of cable tray shall be 3 meters. Cost including GI angle as per site requirements, Fabrication of supports, Painting of supports by two coats of red oxide followed by two coats of enamel paint, Installation of steel supports including using of fasteners, hardware as per drawings, specification, instruction of Engineer-in-charge. 1) Rate Quoted shall include cold galvanizing paint on welded spots. 2) Rate Quoted shall include site fabrication of required Bends, T-Junction, Elbows, X-Junction, Z-Sections, Reducer etc. and all reauired supporting strcture (G.I angle,G.I Base Angle,G.I Plate at ceiling for fixing of cable tray support including anchor fastner etc) and necessary accesories to comlete the cable tray hanging job 600 x 100 made out of 2 mm thick
GI LADDER TYPE Cable TraysCABLE TRAY Supply, installation, Erection, Testing and Commissioning hot dip GI LADDER TYPE Cable Trays with accessories such as coupling plates, bends, tees, reducers, coupling nut-bolts etc. along with necessary supporting frame, members, angles, clamps etc. of following width. The cost of installation shall include connection, bolting, cutting, etc. with required cable tray support and threaded rod, anchors, etc.as per specification and drawings complete with all required hardware: Supply, Installation, laying and connection of G.I. Ladder type cable tray with bends, tees, clamps and couplers for fixing of cable, cable tie, anchor fastener. The job also includes to paint the structure with two coats of red oxide and two coats color of enamel paint as approved . All material shall be Hot dip galvanised as per IS - 86 micron (630 g/m2) and specifications. The structural steel supports for the trays are to be provided minimum at every 1Mtr distance as per technical specifications. Standard length of cable tray shall be 3 meters. Cost including GI angle as per site requirements, Fabrication of supports, Painting of supports by two coats of red oxide followed by two coats of enamel paint, Installation of steel supports including using of fasteners, hardware as per drawings, specification, instruction of Engineer-in-charge. 1) Rate Quoted shall include cold galvanizing paint on welded spots. 2) Rate Quoted shall include site fabrication of required Bends, T-Junction, Elbows, X-Junction, Z-Sections, Reducer etc. and all reauired supporting strcture (G.I angle,G.I Base Angle,G.I Plate at ceiling for fixing of cable tray support including anchor fastner etc) and necessary accesories to comlete the cable tray hanging job 450 x 100 made out of 2 mm thick
GI LADDER TYPE Cable TraysCABLE TRAY Supply, installation, Erection, Testing and Commissioning hot dip GI LADDER TYPE Cable Trays with accessories such as coupling plates, bends, tees, reducers, coupling nut-bolts etc. along with necessary supporting frame, members, angles, clamps etc. of following width. The cost of installation shall include connection, bolting, cutting, etc. with required cable tray support and threaded rod, anchors, etc.as per specification and drawings complete with all required hardware: Supply, Installation, laying and connection of G.I. Ladder type cable tray with bends, tees, clamps and couplers for fixing of cable, cable tie, anchor fastener. The job also includes to paint the structure with two coats of red oxide and two coats color of enamel paint as approved . All material shall be Hot dip galvanised as per IS - 86 micron (630 g/m2) and specifications. The structural steel supports for the trays are to be provided minimum at every 1Mtr distance as per technical specifications. Standard length of cable tray shall be 3 meters. Cost including GI angle as per site requirements, Fabrication of supports, Painting of supports by two coats of red oxide followed by two coats of enamel paint, Installation of steel supports including using of fasteners, hardware as per drawings, specification, instruction of Engineer-in-charge. 1) Rate Quoted shall include cold galvanizing paint on welded spots. 2) Rate Quoted shall include site fabrication of required Bends, T-Junction, Elbows, X-Junction, Z-Sections, Reducer etc. and all reauired supporting strcture (G.I angle,G.I Base Angle,G.I Plate at ceiling for fixing of cable tray support including anchor fastner etc) and necessary accesories to comlete the cable tray hanging job 300 x 100 made out of 2 mm thick
GI LADDER TYPE Cable TraysCABLE TRAY Supply, installation, Erection, Testing and Commissioning hot dip GI LADDER TYPE Cable Trays with accessories such as coupling plates, bends, tees, reducers, coupling nut-bolts etc. along with necessary supporting frame, members, angles, clamps etc. of following width. The cost of installation shall include connection, bolting, cutting, etc. with required cable tray support and threaded rod, anchors, etc.as per specification and drawings complete with all required hardware: Supply, Installation, laying and connection of G.I. Ladder type cable tray with bends, tees, clamps and couplers for fixing of cable, cable tie, anchor fastener. The job also includes to paint the structure with two coats of red oxide and two coats color of enamel paint as approved . All material shall be Hot dip galvanised as per IS - 86 micron (630 g/m2) and specifications. The structural steel supports for the trays are to be provided minimum at every 1Mtr distance as per technical specifications. Standard length of cable tray shall be 3 meters. Cost including GI angle as per site requirements, Fabrication of supports, Painting of supports by two coats of red oxide followed by two coats of enamel paint, Installation of steel supports including using of fasteners, hardware as per drawings, specification, instruction of Engineer-in-charge. 1) Rate Quoted shall include cold galvanizing paint on welded spots. 2) Rate Quoted shall include site fabrication of required Bends, T-Junction, Elbows, X-Junction, Z-Sections, Reducer etc. and all reauired supporting strcture (G.I angle,G.I Base Angle,G.I Plate at ceiling for fixing of cable tray support including anchor fastner etc) and necessary accesories to comlete the cable tray hanging job 150 x 100 made out of 2 mm thick
Supply, Installation, laying and connection of G.I. Perforated Type cable tray with bends, tees, clamps and couplers for fixing of cable, cable tie, anchor fastener. The job also includes to paint the structure with two coats of red oxide and two coats color of enamel paint as approved . All material shall be Hot dip galvanised as per IS - 86 micron (630 g/m2) and specifications. The structural steel supports for the trays are to be provided minimum at every 1 Mtr distance as per technical specifications. Standard length of cable tray shall be 3 meters. Cost including GI angle as per site requirements, Fabrication of supports, Painting of supports by two coats of red oxide followed by two coats of enamel paint, Installation of steel supports including using of fasteners, hardware as per drawings, specification, instruction of Engineer-in-charge. 1) Rate Quoted shall include cold galvanizing paint on welded spots. 2) Rate Quoted shall include site fabrication of required Bends, T-Junction, Elbows, X-Junction, Z-Sections, Reducer etc. and all reauired supporting strcture (G.I angle,G.I Base Angle,G.I Plate at ceiling for fixing of cable tray support including anchor fastner etc) and necessary accesories to comlete the cable tray hanging job 750 mm width X 62.5 mm depth X 2.0 mm thickness
Supply, Installation, laying and connection of G.I. Perforated Type cable tray with bends, tees, clamps and couplers for fixing of cable, cable tie, anchor fastener. The job also includes to paint the structure with two coats of red oxide and two coats color of enamel paint as approved . All material shall be Hot dip galvanised as per IS - 86 micron (630 g/m2) and specifications. The structural steel supports for the trays are to be provided minimum at every 1 Mtr distance as per technical specifications. Standard length of cable tray shall be 3 meters. Cost including GI angle as per site requirements, Fabrication of supports, Painting of supports by two coats of red oxide followed by two coats of enamel paint, Installation of steel supports including using of fasteners, hardware as per drawings, specification, instruction of Engineer-in-charge. 1) Rate Quoted shall include cold galvanizing paint on welded spots. 2) Rate Quoted shall include site fabrication of required Bends, T-Junction, Elbows, X-Junction, Z-Sections, Reducer etc. and all reauired supporting strcture (G.I angle,G.I Base Angle,G.I Plate at ceiling for fixing of cable tray support including anchor fastner etc) and necessary accesories to comlete the cable tray hanging job 600 mm width X 62.5 mm depth X 2.0 mm thickness
Supply, Installation, laying and connection of G.I. Perforated Type cable tray with bends, tees, clamps and couplers for fixing of cable, cable tie, anchor fastener. The job also includes to paint the structure with two coats of red oxide and two coats color of enamel paint as approved . All material shall be Hot dip galvanised as per IS - 86 micron (630 g/m2) and specifications. The structural steel supports for the trays are to be provided minimum at every 1 Mtr distance as per technical specifications. Standard length of cable tray shall be 3 meters. Cost including GI angle as per site requirements, Fabrication of supports, Painting of supports by two coats of red oxide followed by two coats of enamel paint, Installation of steel supports including using of fasteners, hardware as per drawings, specification, instruction of Engineer-in-charge. 1) Rate Quoted shall include cold galvanizing paint on welded spots. 2) Rate Quoted shall include site fabrication of required Bends, T-Junction, Elbows, X-Junction, Z-Sections, Reducer etc. and all reauired supporting strcture (G.I angle,G.I Base Angle,G.I Plate at ceiling for fixing of cable tray support including anchor fastner etc) and necessary accesories to comlete the cable tray hanging job 450 mm width X 62.5 mm depth X 2.0 mm thickness
Supply, Installation, laying and connection of G.I. Perforated Type cable tray with bends, tees, clamps and couplers for fixing of cable, cable tie, anchor fastener. The job also includes to paint the structure with two coats of red oxide and two coats color of enamel paint as approved . All material shall be Hot dip galvanised as per IS - 86 micron (630 g/m2) and specifications. The structural steel supports for the trays are to be provided minimum at every 1 Mtr distance as per technical specifications. Standard length of cable tray shall be 3 meters. Cost including GI angle as per site requirements, Fabrication of supports, Painting of supports by two coats of red oxide followed by two coats of enamel paint, Installation of steel supports including using of fasteners, hardware as per drawings, specification, instruction of Engineer-in-charge. 1) Rate Quoted shall include cold galvanizing paint on welded spots. 2) Rate Quoted shall include site fabrication of required Bends, T-Junction, Elbows, X-Junction, Z-Sections, Reducer etc. and all reauired supporting strcture (G.I angle,G.I Base Angle,G.I Plate at ceiling for fixing of cable tray support including anchor fastner etc) and necessary accesories to comlete the cable tray hanging job 300 mm width X 62.5 mm depth X 2.0 mm thickness
Supply, Installation, laying and connection of G.I. Perforated Type cable tray with bends, tees, clamps and couplers for fixing of cable, cable tie, anchor fastener. The job also includes to paint the structure with two coats of red oxide and two coats color of enamel paint as approved . All material shall be Hot dip galvanised as per IS - 86 micron (630 g/m2) and specifications. The structural steel supports for the trays are to be provided minimum at every 1 Mtr distance as per technical specifications. Standard length of cable tray shall be 3 meters. Cost including GI angle as per site requirements, Fabrication of supports, Painting of supports by two coats of red oxide followed by two coats of enamel paint, Installation of steel supports including using of fasteners, hardware as per drawings, specification, instruction of Engineer-in-charge. 1) Rate Quoted shall include cold galvanizing paint on welded spots. 2) Rate Quoted shall include site fabrication of required Bends, T-Junction, Elbows, X-Junction, Z-Sections, Reducer etc. and all reauired supporting strcture (G.I angle,G.I Base Angle,G.I Plate at ceiling for fixing of cable tray support including anchor fastner etc) and necessary accesories to comlete the cable tray hanging job 150 mm width X 62.5 mm depth X 2.0 mm thickness
Supply, Installation, laying and connection of G.I. Perforated Type cable tray with bends, tees, clamps and couplers for fixing of cable, cable tie, anchor fastener. The job also includes to paint the structure with two coats of red oxide and two coats color of enamel paint as approved . All material shall be Hot dip galvanised as per IS - 86 micron (630 g/m2) and specifications. The structural steel supports for the trays are to be provided minimum at every 1 Mtr distance as per technical specifications. Standard length of cable tray shall be 3 meters. Cost including GI angle as per site requirements, Fabrication of supports, Painting of supports by two coats of red oxide followed by two coats of enamel paint, Installation of steel supports including using of fasteners, hardware as per drawings, specification, instruction of Engineer-in-charge. 1) Rate Quoted shall include cold galvanizing paint on welded spots. 2) Rate Quoted shall include site fabrication of required Bends, T-Junction, Elbows, X-Junction, Z-Sections, Reducer etc. and all reauired supporting strcture (G.I angle,G.I Base Angle,G.I Plate at ceiling for fixing of cable tray support including anchor fastner etc) and necessary accesories to comlete the cable tray hanging job 100 mm width X 50 mm depth X 1.6 mm thickness
Structure for Cable tray supportSupplying , fabricating and installation of various sizes hangers for cable trays etc made out ot 14/16 guage sheet/Angle/Flat/rod/ channel/box section/Cable tray cover etc with all necessary accessories like bend, juncation boxes, couper, supporting clamps, elbows, Cover, hardware, anchor fastners etc All the necessary fabrication required will be included in the scope of contractor. Scope also includes two coat of primer and two coat of paining of each items on all the sides complete in all respect.
single phase Point wiring INTERNAL WIRING WITH MODULAR TYPE SWITCHES Wiring of points to be done in open/concealed manner in 25 mm dia surface / recessed metal conduit. Wiring shall be done with FRLS type copper flexible wire of 650V/1100V. Separate pipe should be taken for circuit mains. EA of ciruit of the same phases may be taken in same conduit .The circuit shall be laid in 25/40 mm dia surface / recessed metal conduit.The point rate shall include all the necessary piping and wiring from sub panel / Distribution board to switch board & switch board to the batten holder / angle holder / connector / ceiling rose all inclusive except sub panel / Dist board. The wiring shall be done as per relevant prevailing standard. The looping of the wiring should be done in the switch boxes or light and fan point outlet boxes to avoid the junction boxes. The junction boxes and switch boxes for the ceiling light point, fan point etc shall be minimum 60/75 deep. All the necessary jarry in brick plastered walls should be done with machine cutter only , also jarry should be filled with cement, sand and wire mesh as required, the material cost for rough finish shall be included in point rate.Whenever pipes are required to be laid in flooring shall be of.Wiring should be done as per distribtion details. The point rate shall include all the necessary piping and wiring from sub panel / Distribution board to switch board & switch board to switch board and the batten holder / angle holder / connector / ceiling rose all inclusive. No any extra cost provided for mains. Each circuit should have dedicated phase, neutral & earth wire. Wire sizes to be used as under Wire Size for circuit :- Wire Size from LDB to SB : 2.5 mm2 Cu FRLS wire (650 V) (P+N) Earth : 1.5 mm2 Cu FRLS wire (650 V) Wire Size from SB to SB : 2.5 mm2 Cu FRLS wire (650 V) (P+N) Earth : 1.5 mm2 Cu FRLS wire (650 V) Wire Size from SB to LIGHT, FAN, EXHAUST FAN : 1.5 mm2 Cu FRLS wire (650 V) (P+N) & Earth : 1.5 mm2 Cu FRLS wire (650 V) Wire Size from DB to AC, GEYSER. : 4 mm2 Cu FRLS wire (650 V) (P+N) Earth : 2.5 mm2 Cu FRLS wire (650 V) Wire Size from DB to 6/10/16A general purpose plug point : 2.5 mm2 Cu FRLS wire (650 V) (P+N) & Earth : 1.5 mm2 Cu FRLS wire (650 V) For 20/32A plug point - 6 M2m for Phases, Neutral & 4 M2m Earth One light point controlled by one single way 6 A switch.
Light point single phaseOne light point controlled by one SP MCB rate of light point does not include cost of MCB.
Secondary light points controlled by one SP MCB & required all type of accessories to complete the job.
Light point with same switch Loop light point controlled by 6A switch.
One light point controlled by two, two way 6 A switch.
One ceiling fan outlet point controlled by one 6 A switch and hum free electronic type step regulator and cast iron fan box.
One 6 A x 5 pin 250 Volt socket outlet point controlled by one 6 A switch located on switch board.
6 A x 5 pin 250 Volt switched socket outlet point at convenient location.
6/16 A x 250 V switch socket point on one switch box with 2.5 sqmm flexible wires and phase and neutral and 1.5 sq nm flexible Cu. wire as earth wire. The rate should include conduiting upto DB.
6/16A x 250 Volt switched socket outlet point for A.C./ Geyser with 4 sq.mm wire for phase and neutral & 2.5 sq.mm earth wire.
Exhaust fan outlet point with 6A 5 pin socket controlled by one single way switch/MCB located at different location.
Buzzer point controlled by Bell push with modular type buzzer same make as switch.
20A x 250 Volt metal clad socket outlet point with space for SP MCB.
32A 5 pin x 415 Volt (3 Phase) Metal clad socket outlet point with space for TP MCB/ ISOLATOR.
16A Switches and 6/16 Plug Socket enclosures specifically designed for outdoor use IP56.
SITC computer power supply point with 2 nos of 6 amp 5 pin socket & 1 No 6/16A socket with 1 no 16 A Switch with indicator & wiring of computer point will be done through 2 nos.of 2.5 sq. mm Cu. wires as phase & Neutral and 1.5 sq nm flexible Cu. wire as earth wire.
Supplying , fabricating and installation of various sizes junction boxes/clamps/hangers for light fixtures etc made out ot 14 guage sheet/Angle/Flat/rod/ channel/box section etc with all necessary accessories like bend, juncation boxes, couper, supporting clamps, elbows, hardware, anchor fastners etc All the necessary fabrication required will be included in the scope of contractor. Scope also includes two coat of primer and two coat of paining of each items on all the sides complete in all respect.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
MAINS (Other than point wiring) : Supplying and Laying mains with 4 nos. of 16 sq mm Cu. PVC insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and 2 nos 6 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 40 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.
Supplying and Providing mains with 4 nos. of 10 sq mm Cu. PVC insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and 2 nos 4 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 40 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.
Supplying and Providing mains with 4 nos. of 6 sq mm Cu. PVC insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and 2 nos 2.5 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 40 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.
Supplying and Laying mains with 2 nos. of 10 sq mm Cu. PVC insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and 1 no 6.0 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI amd FIA approval with all necessary accessories.
Supplying and Providing mains with 2 nos. of 6 sq mm Cu. PVC insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and 1 nos 4.0 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.
Supplying and Providing mains with 3 nos. of 4 sq mm Cu. PVC insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.
Supplying and Providing mains with 3 nos. of 2.5 sq mm Cu. PVC insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.
Supplying and Providing mains with 3 nos. of 1.5 sq mm Cu. PVC insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.
150mm Wall Race wayWall Race way Supplying, installing, connecting of following size with flexible cover for each compartment with Necessary accessories i.e cover joints, base joints, end cover, seperation partition, internal & external angles, flat angles, flat junction etc. complete in all respect. 50 X 150 mm pvc trunking with body cover & seperator (3 Compartment) including all accessories.
105 mm Wall Race wayWall Race way Supplying, installing, connecting of following size with flexible cover for each compartment with Necessary accessories i.e cover joints, base joints, end cover, seperation partition, internal & external angles, flat angles, flat junction etc. complete in all respect. 50 X 105 mm pvc trunking with body cover & seperator (2 Compartment) including all accessories.
junction boxesSupplying , fabricating and installation of various sizes junction boxes/clamps/hangers for light fixtures etc made out ot 14 guage sheet/Angle/Flat/rod/ channel/box section etc with all necessary accessories like bend, juncation boxes, couper, supporting clamps, elbows, hardware, anchor fastners etc All the necessary fabrication required will be included in the scope of contractor. Scope also includes two coat of primer and two coat of paining of each items on all the sides complete in all respect.
Floor Race way Floor metal Race way Floor Race way Supplying and embedding of following sizes of under floor metal trunking/race way with all accessories made out of pre galvanized steel sheet. steel.Trunking should be clamp with G I strip at Every 1.5 meter on floor.comprising rectangular G.I. extruded tubes including chasing of floor and tiles, cleaning wherever necessary, fixing the raceways, minor civil work with providing sealing at joints at junction box ,earthing complete as required. 300mm X 38mm - 3 Compartment
Floor metal Race wayFloor Race way Supplying and embedding of following sizes of under floor metal trunking/race way with all accessories made out of pre galvanized steel sheet. steel.Trunking should be clamp with G I strip at Every 1.5 meter on floor.comprising rectangular G.I. extruded tubes including chasing of floor and tiles, cleaning wherever necessary, fixing the raceways, minor civil work with providing sealing at joints at junction box ,earthing complete as required. 225mm X 38mm - 3 Compartment
Floor metal Race wayFloor Race way Supplying and embedding of following sizes of under floor metal trunking/race way with all accessories made out of pre galvanized steel sheet. steel.Trunking should be clamp with G I strip at Every 1.5 meter on floor.comprising rectangular G.I. extruded tubes including chasing of floor and tiles, cleaning wherever necessary, fixing the raceways, minor civil work with providing sealing at joints at junction box ,earthing complete as required. 150mm X 38mm - 1 Compartment
Floor metal Race wayFloor Race way Supplying and embedding of following sizes of under floor metal trunking/race way with all accessories made out of pre galvanized steel sheet. steel.Trunking should be clamp with G I strip at Every 1.5 meter on floor.comprising rectangular G.I. extruded tubes including chasing of floor and tiles, cleaning wherever necessary, fixing the raceways, minor civil work with providing sealing at joints at junction box ,earthing complete as required. 100mm X 38mm - 1 Compartment
Floor metal Junction boxJunction box Supplying and fixing of following sizes of adjustable height floor junction box made out of 2 - 3 mm thick pre galvanized sheet with Electrostatic polyster epoxy coating or 275 GSM coating mass. min. 8mm Trap lid to be provide to acodomate the specified flooring. The base of junction box should have pre punched / champhered knockouts on all four sides to accomodate trunking. The system must have smooth curved die cast pillars for ease of pulling cables. The load plate & frame should be capable to adequate load bearing capacity min. 5kN as per EN 50082-2-2.Necessary separating retainers shall be provided for segration of Power, Datta & Multi media cables. Cover plate of junction will be flush with floor complete as required. Adjustable Junction Box 400 X 400 X 65-90mm Height Junction Box
Floor metal Junction boxJunction box Supplying and fixing of following sizes of adjustable height floor junction box made out of 2 - 3 mm thick pre galvanized sheet with Electrostatic polyster epoxy coating or 275 GSM coating mass. min. 8mm Trap lid to be provide to acodomate the specified flooring. The base of junction box should have pre punched / champhered knockouts on all four sides to accomodate trunking. The system must have smooth curved die cast pillars for ease of pulling cables. The load plate & frame should be capable to adequate load bearing capacity min. 5kN as per EN 50082-2-2.Necessary separating retainers shall be provided for segration of Power, Datta & Multi media cables. Cover plate of junction will be flush with floor complete as required. Adjustable Junction Box 300 X 300 X 65-90mm Height Junction Box
Floor metal Junction boxJunction box Supplying and fixing of following sizes of adjustable height floor junction box made out of 2 - 3 mm thick pre galvanized sheet with Electrostatic polyster epoxy coating or 275 GSM coating mass. min. 8mm Trap lid to be provide to acodomate the specified flooring. The base of junction box should have pre punched / champhered knockouts on all four sides to accomodate trunking. The system must have smooth curved die cast pillars for ease of pulling cables. The load plate & frame should be capable to adequate load bearing capacity min. 5kN as per EN 50082-2-2.Necessary separating retainers shall be provided for segration of Power, Datta & Multi media cables. Cover plate of junction will be flush with floor complete as required. Adjustable Junction Box 225 X 225 X 65-90mm Height Junction Box
Floor metal Junction boxJunction box Supplying and fixing of following sizes of adjustable height floor junction box made out of 2 - 3 mm thick pre galvanized sheet with Electrostatic polyster epoxy coating or 275 GSM coating mass. min. 8mm Trap lid to be provide to acodomate the specified flooring. The base of junction box should have pre punched / champhered knockouts on all four sides to accomodate trunking. The system must have smooth curved die cast pillars for ease of pulling cables. The load plate & frame should be capable to adequate load bearing capacity min. 5kN as per EN 50082-2-2.Necessary separating retainers shall be provided for segration of Power, Datta & Multi media cables. Cover plate of junction will be flush with floor complete as required. Adjustable Junction Box 150 X 150 X 65-90mm Height Junction Box
Fly over Junction boxJunction box Supplying and fixing of following sizes of adjustable height floor Cross Over Type junction box made out of 2 - 3 mm thick pre galvanized sheet with Electrostatic polyster epoxy coating or 275 GSM coating mass. min. 8mm Trap lid to be provide to acodomate the specified flooring. The base of junction box should have pre punched / champhered knockouts on all four sides to accomodate trunking from a minimum 50mm to maximum 225mm. The system must have smooth curved die cast pillars for ease of pulling cables. The load plate & frame should be capable to adequate load bearing capacity min. 5kN as per EN 50082-2-2.Necessary separating retainers shall be provided for segration of Power, Datta & Multi media cables. Cover plate of junction will be flush with floor complete as required. The cross over boxes should have flyover units made of abs plastic or metal to route and distribute power, data & other cables. Adjustable Fly over Junction Box - 400 X 400 X 65-90mm Height Cross over / Flyover Junction Box
Fly over Junction boxJunction box Supplying and fixing of following sizes of adjustable height floor Cross Over Type junction box made out of 2 - 3 mm thick pre galvanized sheet with Electrostatic polyster epoxy coating or 275 GSM coating mass. min. 8mm Trap lid to be provide to acodomate the specified flooring. The base of junction box should have pre punched / champhered knockouts on all four sides to accomodate trunking from a minimum 50mm to maximum 225mm. The system must have smooth curved die cast pillars for ease of pulling cables. The load plate & frame should be capable to adequate load bearing capacity min. 5kN as per EN 50082-2-2.Necessary separating retainers shall be provided for segration of Power, Datta & Multi media cables. Cover plate of junction will be flush with floor complete as required. The cross over boxes should have flyover units made of abs plastic or metal to route and distribute power, data & other cables. Adjustable Fly over Junction Box - 300 X 300 X 65-90mm Height Cross over / Flyover Junction Box
Fly over Junction boxJunction box Supplying and fixing of following sizes of adjustable height floor Cross Over Type junction box made out of 2 - 3 mm thick pre galvanized sheet with Electrostatic polyster epoxy coating or 275 GSM coating mass. min. 8mm Trap lid to be provide to acodomate the specified flooring. The base of junction box should have pre punched / champhered knockouts on all four sides to accomodate trunking from a minimum 50mm to maximum 225mm. The system must have smooth curved die cast pillars for ease of pulling cables. The load plate & frame should be capable to adequate load bearing capacity min. 5kN as per EN 50082-2-2.Necessary separating retainers shall be provided for segration of Power, Datta & Multi media cables. Cover plate of junction will be flush with floor complete as required. The cross over boxes should have flyover units made of abs plastic or metal to route and distribute power, data & other cables. Adjustable Fly over Junction Box - 225 X 205 X 65-90mm Height Cross over / Flyover Junction Box
EARTHING SITC of UL Listed Copper bonded Solid Steel Rods are to be used as vertical electrode. These electrodes shall be made of high tensile low carbon steel rod, molecular bonded with 99.9% electrolytic copper with minimum coating thickness of 250 microns. 17.2 mm dia copper bonded rod with minimum length of the earth rod shall be 3 meters which is a single rod should beas per IEC 62561-2. Universal clamp of required size should be made up of SS304. Earth enhancement compund of 25kg should be used made graphite and carbon should be of conductive concrete based mineral compound producing low resistance of an earth termination system. Material of the earthing enhancing compound shall be chemically inert to subsoil. It shall not pollute the environment. Below test report should be submitted for Earth rod should be tested CPRI tested for 45KA Ipeak and 18KA Irms and test reports for Marking, Dimension, Electrical resistanc ebefore and after salt mist test, tensile strength, bend test , adhesion test. The compound shall be tested and certified as per IEC 62561-7 and also fulfill Toxicity Characteristic Leaching Procedure (TCLP) requirements.Earth Chamber Should have an Outer Size: 290(L) x 290(W) x 209(H) mm made of GLASS FIBER PLASTIC Material. Flush Mounted, removable and lockable cover of the earth pit should be able to withstand 60KN.
GI. Wire/strips earthing Earth wire/strips : Supply and laying CU/ GI. earthing required size strips for interconnecting the earthing stations, panels, DB s etc. in built up trenches, on walls/ceiling, buried in ground generally as specified and shown on drawings complete with Fixing accessories, Corrosion protection of buried conductors with bituminous coating and covered with PVC tapes. 25 mm X 3 mm Hot dip G.I. strip
GI. Wire/strips earthing Earth wire/strips : Supply and laying CU/ GI. earthing required size strips for interconnecting the earthing stations, panels, DB s etc. in built up trenches, on walls/ceiling, buried in ground generally as specified and shown on drawings complete with Fixing accessories, Corrosion protection of buried conductors with bituminous coating and covered with PVC tapes. 25 mm X 6 mm Hot dip G.I. strip
GI. Wire/strips earthing Earth wire/strips : Supply and laying CU/ GI. earthing required size strips for interconnecting the earthing stations, panels, DB s etc. in built up trenches, on walls/ceiling, buried in ground generally as specified and shown on drawings complete with Fixing accessories, Corrosion protection of buried conductors with bituminous coating and covered with PVC tapes. 50 x 6 mm Hot dip G.I. strip
GI. Wire/strips earthing Earth wire/strips : Supply and laying CU/ GI. earthing required size strips for interconnecting the earthing stations, panels, DB s etc. in built up trenches, on walls/ceiling, buried in ground generally as specified and shown on drawings complete with Fixing accessories, Corrosion protection of buried conductors with bituminous coating and covered with PVC tapes. 50 x 10 mm Hot dip G.I. strip
GI. Wire/strips earthing Earth wire/strips : Supply and laying CU/ GI. earthing required size strips for interconnecting the earthing stations, panels, DB s etc. in built up trenches, on walls/ceiling, buried in ground generally as specified and shown on drawings complete with Fixing accessories, Corrosion protection of buried conductors with bituminous coating and covered with PVC tapes. 75 x 6 mm Hot dip G.I. strip
CU Wire/strips earthing Earth wire/strips : Supply and laying CU/ GI. earthing required size strips for interconnecting the earthing stations, panels, DB s etc. in built up trenches, on walls/ceiling, buried in ground generally as specified and shown on drawings complete with Fixing accessories, Corrosion protection of buried conductors with bituminous coating and covered with PVC tapes. 50 x 6 mm Copper strip
8 gauge bare GI. earth wireEarth wire/strips : Supply and laying CU/ GI. earthing required size strips for interconnecting the earthing stations, panels, DB s etc. in built up trenches, on walls/ceiling, buried in ground generally as specified and shown on drawings complete with Fixing accessories, Corrosion protection of buried conductors with bituminous coating and covered with PVC tapes. No.8 gauge bare GI. earth wire
38mm x 6 mm 1ft Long GI.earth link Earth wire/strips : Supply and laying CU/ GI. earthing required size strips for interconnecting the earthing stations, panels, DB s etc. in built up trenches, on walls/ceiling, buried in ground generally as specified and shown on drawings complete with Fixing accessories, Corrosion protection of buried conductors with bituminous coating and covered with PVC tapes. Earth Link : 38mm x 6 mm 1ft Long GI.earth link fixed by necessary screws on wall.
STRUCTURAL DOWN CONDUCTOR: Design,Supply, Installation,Testing and commissioning of non corossive 10 mm dia Cu bonded solid round conductor used for structural riser inside the column. Multi conductor bonding clamp for interconnecting conductor with rebar in column and other suitable accessories. All the Lightning Protection components are tested as per IEC 62561-1& 2. Make : CAPE (RAYCAP)/ ABB
EARTHING SYSTEM Design,Supply, Installation,Testing and commissioning of non corossive 10 mm dia Cu bonded solid round conductor used for Earth termination with necessary supporting accessories. All the Lightning Protection components are tested as per IEC 62561-1& 2. Make : CAPE (RAYCAP)/ ABB
EQUIPOTENTIAL POINTS: Design,Supply, Installation,Testing and commissioning of equipotential points are used for every vertical riser and tapoff points. All the Lightning Protection components are tested as per IEC 62561-1& 2.
PERIPHERAL RING AROUND THE BUILDING TO AVOID SIDE FLASH: Design,Supply, Installation,Testing and commissioning of non corossive 10 mm dia Cu bonded solid round conductor used for structural riser inside the floor slab. Diagonal clamp for interconnecting conductor with rebar in column & Earth stud point and other suitable & connectingaccessories. All the Lightning Protection components are tested as per IEC 62561-1
EARTHING FOR ELECTRICAL SYSTEM Design,Supply, Installation,Testing and commissioning of TNS PME safety earthing for electrical installation conforming to IS 732, IS 3043, NBC-2016,IEC 60364-5-54 AND IS/IEC 62305-3.”. Earthmat, risers and provision for earth connection of Transformer, DG,Main panel, Lift, AHU, Chiller and other MEP equipments. Earth Stud 3 CU Rated Current (CPRI TESTED): Irms- 29 KA per sec; Ipeak- 79 KA per sec Earth Stud 5 CU Rated Current (CPRI TESTED): Irms- 41 KA per sec; Ipeak- 102 KA per sec Earth Stud 3 SS Rated Current (CPRI TESTED): Irms- 8 KA; Ipeak- 19 KA Per sec Earth Stud 1 SS Rated Current (CPRI TESTED): Irms- 5 KA; Ipeak- 11 KA Per sec Design,Supply, Installation,Testing and commissioning of localised (floorwise) functional earthing system for ELV / BMS / UPS / Isolation transformer (if any) etc., Make : CAPE (RAYCAP)/ ABB
EXOTHERMIC WELDING AT EARTH GRID INSIDE SOIL Installation of exothermic welding used in earthing system .
EQUIPOTENTIAL BONDING MAIN EARTHING TERMINAL (INSTALLATION CONTRACTOR SCOPE) Design and Supply, Installation,Testing and commissioning of Equipotential bonding rail Heavy duty with respect to short circuit rating with connecting accessories used in protective multiple earthing system to meet the requirements of IS 3043.
Testing and verification Electrical installation, inspection shall be made to confirm that electrical equipment which is part of the fixed installation is: All the panels, Distribution boards and all electrical equipments.
Supply, Installation,Testing and commissioning of Surge Protection Device Type 2 Tested as per IEC 61643 Part 11:2011 & UL 1449 4th Edition with following specification: Nominal voltage -230V 50/60Hz and MCOV ≥ 300 V , The Surge Protection Devices shall have TOV withstand ≥ 440 V for 120 min, Nominal Discharge current - 20 kA (8/20μ )sec Max Discharge current - 50 kA (8/20μ sec). Protective Elements are High Energy MOV & GDT and the Protection Modes for : 3 numbers of Type 2 SPD for connection between Phase and Earth and one number of SPD between Neutral and Earth. Short- Circuit Current rating (Isccr) – 50 kA/50 Hz.No Leakage Current Max Back up fuse shall be 315 AgG/gL. Health Status Indication required in all catridge including N to PE. Total Response time -25 Nanosec Make : CAPE (RAYCAP)/ WEIDMULLER/ERICO (The supplier shall submit VDE test certificate)
PVC PIPES 25mm Dia PVC PIPESPVC PIPES Supplying and laying following sizes PVC pipe of approved make in open / concealed in wall manner including excavation and back filling (if required) as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 25 mm dia with GI pulling wire.
32mm Dia PVC PIPESPVC PIPES Supplying and laying following sizes PVC pipe of approved make in open / concealed in wall manner including excavation and back filling (if required) as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 32 mm dia with GI pulling wire.
40mm Dia PVC PIPESPVC PIPES Supplying and laying following sizes PVC pipe of approved make in open / concealed in wall manner including excavation and back filling (if required) as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 40 mm dia with GI pulling wire.
50mm Dia PVC PIPESPVC PIPES Supplying and laying following sizes PVC pipe of approved make in open / concealed in wall manner including excavation and back filling (if required) as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 50 mm dia.
75mm Dia PVC PIPESPVC PIPES Supplying and laying following sizes PVC pipe of approved make in open / concealed in wall manner including excavation and back filling (if required) as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 75 mm dia.
110mm Dia PVC PIPESPVC PIPES Supplying and laying following sizes PVC pipe of approved make in open / concealed in wall manner including excavation and back filling (if required) as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 110 mm dia.
TIMER Supplying,installation,testing and commissioning of Astronomical dual time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.
DWC Pipes 120 MM OD DWC Pipe.DWC Pipes Supplying and laying following sizes Double walled corrugated HDPE pipes confirming IS 14930 Part 1 & Part 2 of approved make in open / concealed in manner including excavation and back filling (if required) as per layout and drawing and re-filling the trenches etc. complete as directed. (NP Class) 120 MM OD DWC Pipe.
90 MM OD DWC PipeDWC Pipes Supplying and laying following sizes Double walled corrugated HDPE pipes confirming IS 14930 Part 1 & Part 2 of approved make in open / concealed in manner including excavation and back filling (if required) as per layout and drawing and re-filling the trenches etc. complete as directed. (NP Class) 90 MM OD DWC Pipe
Fire Stopper SITC of Fire stop mortar system CP 636 , with minimum 2 hours fire rating when tested in accordance with UL 1479/ASTM-E 814 standards, for horizontal openings in floors or slabs after passing service lines like cables/cable bundles, cable trays etc. The mortar shall be a light weight cementitious product and shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be age tested as per Dafstb and DIBT standards. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96. The product shall be age tested as per Dafstb and DIBT standards.The system shall be UL listed & classified and product shall bear the UL and FM approval logo on the packing. If none of UL test certificate comply with actual application, an EJ document prepared by a qualified personnel and based on nearest third party tested & approved systems like UL test certificates & in accordance with IFC guidelines shall be producted by manufacturer. A firestop submittal shall be produced by manufacturer , in accordance with approved passive fire protection method statement, for technical approval. Firestop installation shall be done by Hilti Accredited Firestop Speciality Contractor (HAFSC) or by certified installers gone through Hilti's FIT service and in accordance with Hilti guidelines and UL system test certificates or approved EJ document. Firestop Speciality Contractor needs to submitt work completition certificate along with installation report through Hilti documentation Software CFS DM for periodic inspection & maintenance purpose. The gaps around inaccessible or complicated openings shall be sealed with exapnding firestop foam CP 620 and shall be paid under separate heads and as mentioned below.
SITC expanding firestop foam CP 620, with minimum 2 hours fire rating when tested in accordance with UL 1479/ASTM-E 814, for horizontal openings in floors or slabs made of concrete/ masonry or Gypsum after passing service lines like cable trays or cables/cable bundles. The expanding foam expands seven times its volume to fill the cavity at the time of dispensing the material and shall fully cure within two minutes after dispensing. The product shall be age tested as per Dafstb and DIBT standards. The product shall provide water tightness when tested for W rating as per UL standards and shall carry test certificate for sound insualtion of 50 db when tested in accordance with ASTM E 90. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and shall have a VOC content of approx. 1.3 g/l as per LEED 2009. The product shall be age tested as per Dafstb and DIBT standards.The product shall be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The system shall be UL listed & classified and product shall bear the UL and FM approval logo on the packing. The product shall be age tested as per Dafstb and DIBT standards. If none of UL test certificate comply with actual application, an EJ document prepared by a qualified personnel and based on nearest third party tested & approved systems like UL test certificates & in accordance with IFC guidelines shall be producted by manufacturer. A firestop submittal shall be produced by manufacturer , in accordance with approved passive fire protection method statement, for technical approval. Firestop installation shall be done by Hilti Accredited Firestop Speciality Contractor (HAFSC) and in accordance with Hilti guidelines and UL system test certificates or approved EJ document. Firestop Speciality Contractor needs to submitt work completition certificate along with installation report through documentation Software CFS DM for periodic inspection & maintenance purpose.
Car Stack Parking System Design, supply, installation, testing and commissioning of Electro-Hydraulic Twin Park Palette Parking System based on lifting mechanism through hydraulic dual cylinder and no ceiling and side support required. Platform will be of metal framing with GI platform profiles with powder coated material. It should be complete with power pack hanging on pole oflift structure (approx. 1.5 KW or as per OEM, noise level less than 30db), operator keys, operator stand as per OEM Standards, maintenance free system as no piping on ground level. Average retrieval/parking time should not be greater than 120 seconds & the Lifting speed should be min 3 Meter/Minute best available as per standard. System should be height adjustable having safety features including 14 mechanical laser cut locks with safety sensors.
LIGHT FIXTURES & FANS Light Fixtures type - A LIGHT FIXTURES & FANS Supplying, errecting, connecting, testing and commissioning of following tpe light fixture with all necessary Hardware, Internal Wiring with Lamp, Ballast etc., all required accessories complete in all respect. Any kind of internal Light Fixtures type - A ( with Basic Rate of Rs.1500/-) ( Range up to 2500 Rs
Light Fixtures type - B LIGHT FIXTURES & FANS Supplying, errecting, connecting, testing and commissioning of following tpe light fixture with all necessary Hardware, Internal Wiring with Lamp, Ballast etc., all required accessories complete in all respect. Any kind of internal Light Fixtures type - B ( with Basic Rate of Rs.3500/-) ( Range Above 2500 Rs to up to 4250 Rs)
Light Fixtures type - C LIGHT FIXTURES & FANS Supplying, errecting, connecting, testing and commissioning of following tpe light fixture with all necessary Hardware, Internal Wiring with Lamp, Ballast etc., all required accessories complete in all respect. Any kind of internal Light Fixtures type - C ( with Basic Rate of Rs.5000/-) ( Range Above 4250 Rs )
Supply,Installation, testing and commissioning following sizes ceiling Fans without fan regulator. 36" Dia Sweep Ceiling Fan as per approved colour & high speed type.
48" Dia Sweep Ceiling Fan as per approved colour & high speed type.
56" Dia Sweep Ceiling Fan as per approved colour & high speed type.
Additional fan rod made out of 10 guage GI pipe with all necessary painted and required accessories for fan suspention.
Fan Hook For Above Fan
225/305 mm Exhaust fans 1400 RPM. Supply, Installation,testing and commissioning of following sizes Exhaust Fans of approved make Light duty 225/305 mm. diameter propeller exhaust fans single phase 1400 RPM.
305 mm Exhaust fans 1400 RPM. Supply, Installation,testing and commissioning of following sizes Exhaust Fans of approved make Heavy duty 305 mm. diameter propeller exhaust fans single phase 1400 RPM.
450 mm Exhaust fans 1400 RPM. Supply, Installation,testing and commissioning of following sizes Exhaust Fans of approved make Heavy duty 450 mm. diameter propeller exhaust fans single phase 1400 RPM. With M.S. louvre shutter of the exhaust fan.
External Lighting Pole Supply, erecting,testing, commissioning of 4 Mtr. GI decorative pole of 165 OD X 4.80 mm thk. With 400 X 12 mm round flange with integral type junction box with necessasory reducer / coupler for fixing of light fixtures (post top lantern) & Hinged access door with allen key & gasket require to access the integral junction box, integrated junction box with one coat of zinc oxide complete in all respect as per Drawing. Rate shall be including PU paint of shade as per drawing or as directed by Architect and rate shall be exclusive of cost of the chemical grouted Anchor fastener with necessory RCC foundation. Supplying, erecting, connecting, testing and commissioning of following type External/ Facade Light Fixture with all necessary Hadware, Internal Wiring with Lamp,Ballast etc. all required accessories Complete in all respect.
Any kind of Decorative External/ Facade Light Fixtures type - A ( with Basic Rate of Rs.5,000/-) ( Range up to 10000 Rs
Any kind of Decorative External/ Facade Light Fixtures type - B ( with Basic Rate of Rs.15,000/-) ( Range Above 10,000 Rs to up to 17,500 Rs)
Any kind of Decorative External/ Facade Light Fixtures type - C ( with Basic Rate of Rs.25,000/-) ( Range Above 17,500 Rs )
UPS Supply, Installation, testing & commissioning of 100 KVA UPS Three Phase input and Three Phase output Systems With Inbuilt Galavnic Isolation Transformer, True Online double conversion & fully microprocessor controlled with IGBT Rectifier/ Inverter, Input voltage range Range: '-20 / +20 @ 100 % Load, Input Power Factor > 0.99, Output PF – 1 (Unity) THD i < 53%, EFFICIENCY 94 % ON LINE MODE, Inbuilt maintenance by pass & automatic bypass , along with Sealed maintenance free battery with Power Coanded cabinet for 1hour backup with each UPS, Minimum 72000 VAH (12V x AH x Nos. of Battery), suitable configuration along with battery breaker for every string and open racks complete in all respect including supporting steel structure for base frame of UPS and Battery bank as required . inclusive of interconnecting copper cables, panels, monitoring station and all accessories complete in all respect as required. UPS shall be communicable on open protocol with IBMS.
UPS Supply, Installation, testing & commissioning of 10 KVA UPS Three Phase input and Three Phase output Systems With Inbuilt Galavnic Isolation Transformer, True Online double conversion & fully microprocessor controlled with IGBT Rectifier/ Inverter, Input voltage range Range: '-20 / +20 @ 100 % Load, Input Power Factor > 0.99, Output PF – 1 (Unity) THD i < 53%, EFFICIENCY 94 % ON LINE MODE, Inbuilt maintenance by pass & automatic bypass , along with Sealed maintenance free battery with Power Coanded cabinet for 30 min battery backup with each UPS, Minimum 10080 VAH (12V x AH x Nos. of Battery) , suitable configuration along with battery breaker for every string and open racks complete in all respect including supporting steel structure for base frame of UPS and Battery bank as required . inclusive of interconnecting copper cables, panels, monitoring station and all accessories complete in all respect as required. UPS shall be communicable on open protocol with IBMS.
UPS Supply, Installation, testing & commissioning of 5 KVA UPS Single Phase input and Single Phase output Systems With Inbuilt Galavnic Isolation Transformer, True Online double conversion & fully microprocessor controlled with IGBT Rectifier/ Inverter,along with Sealed maintenance free battery with Power Coanded cabinet for 30 min battery backup with each UPS, Minimum 5376 VAH (12V x AH x Nos. of Battery) , suitable configuration along with battery breaker for every string and open racks complete in all respect including supporting steel structure for base frame of UPS and Battery bank as required . inclusive of interconnecting copper cables, panels, monitoring station and all accessories complete in all respect as required. UPS shall be communicable on open protocol with IBMS.
Aviation Light Supply, Installation, testing & commissioning of ICAO compliant IP65 LED aviation obstruction light fixture with 1Xhigh power LED having Aviation Red(ICAO) light color with power consumption <5W,light intensity > 10Cd,opearating voltage range 100-270V AC,with life of 50000 burning hrs with 70% lumen maintemance.Wind load at 200Km/h should be <40N.Fixture should have bird spike to ensure cleanliness of polycarbonate diffuser LED Light source .
Solar Plant rooftop mounted solar system plantSolar Rooftop Design, supply, testing at manufacturers place, transit, Installation, testing, commissioning and performance testing of grid connected rooftop mounted solar photovoltaic system plant on roof of building in GIFT City with associated components for fully commissioning of plant, which includes but not limited to supply, installation, testing and commissioning of Solar panel, steel structure, grid connected string Inverter with open and shareable API, having redundant ethernet port, AC and DC cables, and their terminals/ terminations/ connectors, Lighting arrester,earthing work by using maintenance free earthing, pv panel joints fill by sealants sealant all complete work for fully commissioning of solar plant on each building. It also includes interconnection of solar plant to GRID on plant main LT panel along with installation of metering arrangement and preparing solar dashboard showing real time solar generation, current and voltage profiles.
Telephone And Data Distribution System PVC Conduits Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as per technical specification etc. as required. 25 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 40 mm
Tag Blocks - Multipair Telephone Cable Termination Supply & fixing of 10 pair MDF unit with required modules in a fabricated CRCA powder coated junction box of size 450x250x100 with two no. of pad-lock, provision for earthing, as per technical specification etc. as required.
Supply & fixing of 200 pair MDF unit with required modules in a fabricated CRCA powder coated junction box of size 450x250x100 with two no. of pad-lock, provision for earthing, as per technical specification etc. as required.
Supply & fixing of 500 pair MDF unit with required modules in a fabricated CRCA powder coated junction box of size 450x250x100 with two no. of pad-lock, provision for earthing, as per technical specification etc. as required.
Cabling - Multipair Cables Supplying & erecting approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs & wrapped with FR PVC tape & sheathed with FR PVC or HFFR outer jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos. of pairs. With necessary connections. A Conductor Size 0.5 mm. - Armoured. (Jelly Filled) - Ten Pairs
Supplying & erecting approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs & wrapped with FR PVC tape & sheathed with FR PVC or HFFR outer jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos. of pairs. With necessary connections. A Conductor Size 0.5 mm. - Armoured. (Jelly Filled) - One Hundred Pairs
Telephone / Data Networking Cabling CAT6 UTP Components for Other Area Supply and laying of specified make UTP CAT6 LSZH cable in prelaid PVC conduits / pipes / raceway, but without the cost of raceway or pipe. (The cable is to be drawn from individual workstation/device/desktop area to the central communications/server room. Terminations to be carried out in any intermediate wiring closets/telecom closets by way of racks/MDF/IDF), as per technical specification etc. as required.
Supply and laying of specified make UTP CAT6 Armoured cable in prelaid PVC conduits / pipes / raceway, but without the cost of raceway or pipe. (The cable is to be drawn from individual workstation/ device/ desktop area to the central communications/server room. Terminations to be carried out in any intermediate wiring closets/telecom closets by way of racks/MDF/IDF), as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of Single UTP CAT6 RJ-45 I/O of specified make inclusive of termination of CAT6 cable at each IO at workstation area / device / desktop/ Data, as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of Single UTP CAT6 RJ-45 I/O of specified make inclusive of termination of CAT6 cable at each IO at Equipment Side, as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of CAT6 UTP RJ-45 Patch Cords Solid Conductor 3ft for data (Hub Side)-Data, as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of CAT6 UTP RJ-45 Patch Cords Solid Conductor 7ft for Data (User Side)- Data, as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of Unloaded UTP CAT6 Gigabit Modular Patch Panel for 24 ports in 1U form factor as per the tender specifications, with universal A/B labeling and 110 connector terminations on rear of panel allowing for quick and easy installation of 23 AWG cable.-Data includes Data, Voice, CCTV, Wi-Fi as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of Singlex Face Plate with required back box for mounting IO with required back box as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of Duplex Faceplate with required back box for mounting IO with required back box as per technical specification etc. as required.
Data Networking - Fiber Optic Cable and Components Supply, Installation, Testing & Commissioning of 06 Core Single Mode Central Loose Tube, ECCS Armored, HDPE Outdoor Cable, 9/125 Single Mode OS2 Fiber Cabel where ever required in prelaid conduits / RCC hume pipes/HDPE/DWC, whichever maybe available, as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of 12 Core Single Mode Central Loose Tube, ECCS Armored, HDPE Outdoor Cable, 9/125 Single Mode OS2 Fiber Cabel where ever required in prelaid conduits / RCC hume pipes/HDPE/DWC, whichever maybe available, as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of 24 Core Single Mode Multi Loose Tube, ECCS Armored, HDPE Outdoor Cable, 9/125 Single Mode OS2 Fiber Cabel where ever required in prelaid conduits / RCC hume pipes/HDPE/DWC, whichever maybe available,as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of 19-inch 24 Port LIU, rack mounted , Fully loaded with 2 X 12 Ports Adaptor Connector Panel & with Splice Tray, inclusive of all mechanical accessories with out pigtail, as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of 19-inch 48 Port LIU, rack mounted , Fully loaded with 4 X 12 Ports Adaptor Connector Panel & with Splice Tray, inclusive of all mechanical accessories with out pigtail, as per technical specification etc. as required.
Supply, Splicing,Testing & Commissioning/ Termination of LC-Style Pigtail, 9/125, Singlemode, 1.5 meter, as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of LC-LC single mode duplex fiber optic patch cord 3mtr, as per technical specification etc. as required.
Networking Enclosures Supply, Installation, Testing & Commissioning of 15U (600W X 600D)MM Wall mount closed rack with front glass door, fan tray on top, perforated rear doors, keyboard tray with shelf. Casters & 2 nos vertical power strip with std, as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of 24U (600W X 600D)MM Wall mount closed rack with front glass door, fan tray on top, perforated rear doors, keyboard tray with shelf. Casters & 2 nos vertical power strip with std, as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of 42U (800W X 800D)MM floor mount closed rack complied with DIN-41494 and current industry practices, Stell Door - Plain, Vented at Bottom, Fully perforated and dual perforated, Glass Door with optional vented side trims for front to back air flow, fully recessible 19" split mounting angles at rear, top and bottom cover with cable entry provision, loading rate of 850kg, with required accessories as per tender specification for Server Room.
Supply, Installation, Testing & Commissioning of 42U (800W X 1000D)MM floor mount closed rack complied with DIN-41494 and current industry practices, Stell Door - Plain, Vented at Bottom, Fully perforated and dual perforated, Glass Door with optional vented side trims for front to back air flow, fully recessible 19" split mounting angles at rear, top and bottom cover with cable entry provision, loading rate of 850kg, with required accessories as per tender specification for Server Room.
Supplying , fabricating and installation of various sizes MS race way / junction boxes/clamps/ hangers / enclosure for ELV Fixtures/ for cable trays / Base for Display mounting / Flange for Display etc. made out of 14 gauge sheet/Angle/Flat/rod/ channel/box section etc with all necessary accessories like bend, junction boxes, coupler, supporting clamps, elbows, hardware, anchor fasteners complete with Cutting, welding, grinding, finishing necessory grouting,cementing, plastering etc.. All the necessary fabrication required will be included in the scope of contractor. Scope also includes two coat of primer and two coat of paining of each items on all the sides complete in all respect as instructed by Architect / project in charge.
Active Components Network Switch TYPE-1 Core Switch Supplying, installation, testing and commissioning of Layer 3 Core fiber aggregation networking switch, 24 nos. SFP / SFP+ fiber optics ports, Additional 4nos. of QSFP+, 40G DAC Cable For HA, 1 AC power supply built in and inclusive of redundant power supply and redundant fans as per technical specification etc. as required.
Type 2 Switch: 24 Port POE Supplying, installation, testing and commissioning of Layer 2 manageable networking switch, 24 # 10/100/1000Tx ports, all 24 ports shall be capable of providing PoE+ as per 802.3at, minimum 4 SFP+ ports, as per technical specification etc. as required.
Type 3 Switch: 24 Port Non POE Supplying, installation, testing and commissioning of Layer 2 manageable networking switch, 24 # 10/100/1000Tx ports,minimum 4 SFP+ ports, as per technical specification etc. as required.
Supplying, installation, testing and commissioning of 10G SFP+ Single mode transceiver, 1310nm, 2Km, LC connector, inclusive of any hardware such as modules for populating SM-LC transceivers as per technical specification etc. as required.
Supplying, installation, testing and commissioning of Firewall for Minimum 20 users and expandable up to 100 users as per technical specification etc. as required.
WI-FI COMPONENTS Supply, Installation, Testing and Commissioning of Wireless indoor Access Point supporting Dual band with Wi-Fi 6 operation with MIMO support 4x4 , 3 spatial streams, One 10/100/1000 BASE-TX auto-sensing (RJ45) PoE port, as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of Hardware based Wireless Access Controller, License with Minimum 100 Access point and Expandable up to 200 access point, as per tender specification etc. as required.
EPABX COMPONENTS Supply, Installation, Testing and Commissioning of IP PBX Communication system comprising with following specifications: 100% IP Core, Non-Blocking 1 PRI Trunk interface with PRI Card Loaded. 8 Analog trunk interface via FXO gateway 50 IP Phones Licenses. 128 Analog Extension interaface via FXS gateway Expandable up to 500 IP Users and 30 - IVRs - call center agents for helpdesk setup Must suppport Active - Active server redundancy to achieve high availability (HA) operation Must Support in - built 100 % Audio call recording Must support in-built IVRs and dial center features (inbound/outbound) Must support Inbuilt CDR (Call Details Software) and as per detailed technical specifications.
Supply, Installation, Testing and Commissioning of industry-standard intel based server, The minimum specifications required are as follows : - Processor : Quad Core Intel Xeon, Dual Core, i7 or above - Memory : Minimum 16 GB - Hard Disk : SATA SSD with 1 TB - Oerating System : Linux SUSE - Vendors to provide Duplicate Servers in Hot Standby Mode as per tender specification etc. as required.
Supply and Installation of SIP extensions licenses pack (10 SIP extensions) as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of 4 Line LCD display IP / SIP Hardphone with 16 keys for call appearance / programmable feature key buttons – with dual LEDs (red, green) - three contextual softkey buttons. as per tender specification etc. as required.
Supply, Installation, Testing and Commissioning of Operator Console - software based console including PC to be provided by vendor
Addressable Fire Alarm & Detection System Supplying, installation, testing and commissioning of microprocessor based intelligent addressable main fire alarm panel, It shall have UL listed 10th edition, central processing unit with the following loop modules and capable of supporting not less 250 devices includes minimum 120 detectors per loop and loop length up to 1.5 km, network communication card, LCD display with touch screen or other keypad and The panel shall support up to 5000 programmable Cause and Effects entries; over 40,000 inputs and outputs, 10,000 events log @ 1 second resolultion, 2000 software zones, 5000 software groups, power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Irrespective of whether or not mentioned in the boq, all necessary interfaces - such as hardware and software - for interconnecting all fire alarm panels at site shall be provided in the system(s). Minimum 10 Loop Panel as per technical specification etc. as required.
Supplying, installation, testing & commissioning of intelligent interface unit BACnet/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required.
Supply, Installation, Testing and Commissioning of Graphix Software. It shall have ability to import loop explorer configuration file to graphix file, Drag and drop from device tree to maps, real time graph of device analog values, unlimited map linking, display and control for multiple panels, Event history can be viewed, filtered and exported to text or HTML documents. as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of Network Repeater Panel. The Panel shall have Minimum Full color 7” (800 x 480 pixel) interface, Replicates information displayed at the FACP, Automatic display brightness adjustment, Internal buzzer, Connects via control panel network terminals, Low current, 24V DC powered, Configurable functionality, Enable key-switch, Sheet steel enclosure, UL approved as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of Analog Multi-Criteria Sensor Features, Low profile - only 2" high including base, variable sensitivity from 0.7 to 4% obs/Ft Simple and reliable device addressing, Automatic compensation for sensor contamination , Built in Fire test feature, Two built-in power/alram LEDs, programmable non-polling LEDs, Non-directional Smoke chamber, Vandal resistant security locking feature, Approved by UL and FM as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of Fixed Temperature/Rate of Rise sensor, Low profile-only 2.00" high, including base, simple and reliable device addressing method, Rate of rise temperature threshold = 15° F/Min, Adjustable threshold temperature = 135° - 190°, Approved by UL and FM as per technical specification etc. as required.
Supplying, installation, testing & commissioning of Response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supply, Installation, Testing and Commissioning of Analog Duct Detector ability to detect and limits the spread of smoke throughout building HVAC ducts, Installs quickly and easily, No screens or filters to clean, Rugged gray steel back box with clear cover, Remote LED alarm indication capability, Meets UL 268A requirements. Approved by UL as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of Projected Beam Smoke Detector with monitor module. The device should have standard features including Microprocessor based for Reliability, Simple setup and alignment with signal strength LEDs, Provide 60 feet on center linear protection at a range of 32.8 feet to 328 feet, Automatic compensation for signal drift or dirty lens, Three field adjustable sensitivity settings, form A alarm and Form B trouble contacts, Color coded emitter (red) and receiver (green) labels for easy recognition, Adjustable to one of the three obscuration settings of 25%, 50% or 70% per span, voltage and RF transient protection, External red LED when alarm condition is indicated. Approved by UL and FM as per technical specification etc. as required.
Supplying, installation, testing & commissioning of Addressable Monitor module with required mounting accessories complete as required. as per technical specification etc. as required.
Supplying, installation, testing & commissioning of Addressable Control module with required mounting accessories complete as required. as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of Short Circuit / Fault Isolator. The device shall have ability to locate between any devices on the SLC loop, Indicate of a single short circuit by a yellow LED, UL Approved as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of Addressable Single Action Manual Pull Station features inculding Addressable intergrated design, All metal construction, Extremely easy to operate, Bi-colored status LED indicates standby and Alarm conditions, Address is programmable in EEPROM, Enclosed switch with glass rod, Terminals accept up to 14AWG wire, ADA compliant. Approved by UL and FM as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of low profile Horn/Strobe. The device shall have Nominal voltage 24VDC. The device shall produce 100 dBA @ 10ft and has a minimum flash rate of 1Hz regardless of input voltage. The device approved by UL and CSFM as per technical specification etc. as required.
Supplying, installation, testing & commissioning of addressable Phone control module complete as required. as per technical specification etc. as required.
Supplying, installation, testing & commissioning of Fire Fighter Telephone Handset with required mounting accessories complete as required. as per technical specification etc. as required.
Supplying, installation, testing & commissioning of Fire Fighter Phone Jack complete as required. as per technical specification etc. as required.
Supplying, Laying, testing & commissioning of Linear Heat Detector Cable ( 155ºF (68ºC) Alarm Temperature) as per technical specification etc. as required.
Supplying and drawing of cable Fire Retardant PVC insulated annealed tinned copper (ATC) stranded conductor cable in the existing surface / recessed steel Single twisted pair, 2-core, 1.5 sqmm ATC FRLS cable, For FAS System conduit of following pairs, cores and size including connections and interconnections as per technical specification etc. as required.
Supplying and drawing of cable 2 core x 1.5 sqmm twisted pair fire alarm armoured cable, Annealed Tinned Copper (ATC) stranded conductor having PVC insulation, steel wire armouring & FRLS outer sheath complete as required. as per technical specification etc. as required.
Supplying and fixing of following sizes of Steel / MS conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Digital Public Address & Evacuation System Supply, Installation, Testing and Commissioning of 6 zone IP based, Digital Voice Alarm controller with Master/Slave expandable upto 96 zones. The voice alarm controller shall be able to connect directly over Ethernet without using any connectors. The controller shall have its own PTT Mic for emergentcy communications. It shall offer audio playing, zone control, fault monitoring, log recording, volume control and amplifier switchover. The Voice alarm controller shall offer 255 Priorities, me schedule broadcasts, Capable of amplifier redundancy, 8 trigger inputs/outputs to meet complex PA requirements
Supply, Installation, Testing and Commissioning of Network Resource Interface, Provides 4 AUX balanced audio input for digitalization of the external analog audio source and routing to the network, Built-in 4G SD card as internal audio source, 4 Ethernet interfaces allow communication of multiple system manager controller, Has 2 x RS-485 communication terminals for integration with fire panel., as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of integrated Audio source with the following features : Two single CD\USB\SD and DAB\FM line outputs can play music applications in two areas, The volumes of the two line outputs can be adjusted separately, CD\USB\SD has three play modes: single play, all play and repeated play, DAB\FM can preset 10 channels of programs, RS485 remote control interface as per the technical specifications etc. as required.
Supply, Installation, Testing and Commissioning of 1 X 500W Class-D Amplifier with 1 independent channel and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection, as per the technical specifications etc. as required.
Supply, Installation, Testing and Commissioning of 6W Metal Ceiling Speaker with required mouting brackets & back box as per site requirements featured with max SPL1M/1W 96dB . Frequency response of 80Hz-20KHz with a dispersion angle of 160 deg. The speaker should have tappings at 6W/3W/1.5W with required back box as per site requirement and architect approval, as per the technical specifications etc. as required.
Supply, Installation, Testing and Commissioning of 12W Weather proof Wall Speaker with required mouting brackets as per site requirements max SPL1M/1W 96dB . Frequency response of 80Hz-20KHz with a dispersion angle of 160 deg. The speaker should have tappings at 12W/6W/3W, as per the technical specifications etc. as required.
Supply, Installation, Testing and Commissioning of Unidirectional 20W Sound Projector (IP55) with max SPL1M/1W 106dB . Frequency response of 150Hz-15KHz. The speaker shoud have tappings at 20/10/5W as per the technical specifications etc. as required.
Supplying and drawing of cable Fire Retardant PVC insulated annealed tinned copper (ATC) stranded conductor cable in the existing surface / recessed steel Single twisted pair, 2-core, 1.5 sqmm ATC FRLS cable, For FAS System conduit of following pairs, cores and size including connections and interconnections as per technical specification etc. as required.
Supplying and drawing of cable 2 core x 1.5 sqmm twisted pair fire alarm armoured cable, Annealed Tinned Copper (ATC) stranded conductor having PVC insulation, steel wire armouring & FRLS outer sheath complete as required. as per technical specification etc. as required.
Supplying and fixing of following sizes of Steel / MS conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
IP Based Video Surveillance / CCTV System Supply, Installation, Testing & Commissioning of IP Network TDN Low-Light IR Bullet Camera, 1/3" CMOS, 4 MP @ 25fps, Min. Illumination required 0.01 lux @ F1.6 (color), 140dB True WDR, Min. Pixels 2560x1440, triple stream, 3 to 9 mm motorized focus and zoom lens, BLC, HLC, 3DNR, Privacy Mask, IR LEDs Smart IR with upto 30m IR distance, Dual channel Audio G.711a/G.711u/AAC, 256GB SD card support, Alarm: 2 In/ 1out, PoE, H.264 High Profile and MJPEG, Inbuilt analytics Trigger line/Intrusion/Loitering, PoE Class 3 and 12V DC, IP 67, IK 10 vandal proof, Certifications: ONVIF Profile S compliant, UL, CE, FCC & RoHS certified, as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of IP Network TDN Low-Light IR Dome Camera, 1/3" CMOS, 4 MP @ 25fps, Min. Illumination required 0.01 lux @ F1.6 (color), 140dB True WDR, Min. Pixels 2560x1440, triple stream, 3 to 9 mm motorized focus and zoom lens, BLC, HLC, 3DNR, Privacy Mask, IR LEDs Smart IR with upto 30m IR distance, Dual channel Audio G.711a/G.711u/AAC, 256GB SD card support, Alarm: 2 In/ 1out, PoE, H.264 High Profile and MJPEG, Inbuilt analytics Trigger line/Intrusion/Loitering, PoE Class 3 and 12V DC, IP 67, IK 10 vandal proof, ONVIF Profile S compliant, UL, CE, FCC & RoHS certified, as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of IP Network TDN Low-Light PTZ Camera with auto tracking and face detection, 1/3" CMOS, Min 4 MP and Full HD @ 60/50 fps, triple stream, Min. Illumination required Color: 0.05 Lux at F1.6, 0 Lux at F1.6 (IR on), 120dB True WDR, 4.5 mm - 135 mm 30x motorized focus & zoom lens, BLC, HLC, 3DNR, Defog, Privacy Mask, Dual channel Audio G.711a/G.711u/AAC, 128GB SD card support, Alarm: 2 In/ 1 out, PoE, H.265 and H.264 High Profile and MJPEG, PoE Class 4 and 24VAC, IP 66, Having Operating temp range : –20°C to 70° C. Certifications: ONVIF Profile S compliant, UL, CE, FCC & RoHS certified. as per technical specification etc. as required.
Supplying, installtion, testing and commissioning of Video Management Software supporting ONVIF Profile S & G, PSIA, real time streaming protocol (RTSP) standards, emerging technologies in the industry, like 4K resolution, H.265 video compression codec, 3D PTZ control, Fisheye camera and multi-imager/ lens camera support, and intelligence events. Software proposed shall have scalability of 128 cameras per server with at least 432 licenses to record all the cameras from the Day 1 and expandable up to unlimited cameras. Videom Managment Software shall support simultaneous recording, live monitoring, playback/search of recorded video for up to 4K resolution on all cameras, taking snapshots and viewing presets for PTZ cameras and system management, Videowall management. Video Management Software shall support - 1) Free Firmware upgrade; 2) Lifetime software licence, must not be renewed periodically; 3) It should support unlimited channels; 4) It should support N:1 and N:M redundancy; 5) It should have calender view for better playback investigation; 6) It should support Smart Motion Detection; 7) It Should support Surrounding View feature of cameras; 8) The camera zoom in/out, controlling and setting should be able done from software; 9) The proposed softsware should be latest versin available from OEM 10) VMS Shall support scheduled backfilling of the recordings from the edge storage/SD card of cameras to the server. For details specification refer tender technical specification etc. as required.
Supplying, installtion, testing and commissioning of Server(s) required for the VMS - Industry standard Intel based platform, rack mounted, redundancy architecture for critical hardware components, licensed Microsoft Server operating system and requisite user licenses, licensed application suites, 2 x Quad Core Intel® Xeon latest processors or better, 8 GB of RAM, 2 x 1.2 TB of SAS HDDs, minimum 2 additional hard disk drive bays for expansion, 1,280 x 1,024 Display/ video resolution, 2 X 10/100/1000 ethernet network interface card, Video memory 2GB above, RAID support built-in, DirectX 8.1 above and pre-installed DVD-R/W Drive and Appropriate Licensed Operating Systems as per VMS Requirement. as per technical specification etc. as required. Each server shall support minimum of 128 cameras and must compatible with VMS Software , as per technical specification etc. as required.
Supplying, installation, testing and commissioning of Client Workstation - Industry standard Intel based platform computer system. Intel Core i7 latest generation, 8 GB of RAM DDR3 ,1 TB SATA II hard drive for OS and VMS applications, NVidia card 2 GB graphics card , 1600 x 1200 or higher screen resolution, 1 X 1000Mbps ethernet network interface card ,16x DVD+/- RW Drive alongwith appropriate licenced Operating System, licenced applications suites from OEM and application licences as per the technical specifications etc. as required.
Supplying, installation, testing and commissioning of Network storage required with a capacity to store the content for 288 cameras for 24Hrs x 30 days at 25fps and 1080p (Minimum 350TB from day 1). It should be scalable (should have sufficient expansion bays for HDDs) for at least additional 50 cameras. Vendor shall submit bandwidth and storage calculator for the proposed camera models, as per technical specification etc. as required.
Supplying, installing, testing and commissioning of 65-inch, LED Panel, 16:9 Aspect ratio, 350 cd/m2 Brightness, Anti-glare panel surface with viewing angle 176 degree, 4K pixels resolution, Video Input Interfaces : HDMI Type A Connector x 2, Mini D-sub 15-pin x 1, 20 Watt Built in Speakers with wall mount bracket as per technical specification etc. as required.
Supply installation testing and commissioning of 55" 4K LED Video wall display, 1.8 mm bezel to bezel, 350 Cd/m2 brightness, DVI-D Loop out-Daisy chain, DVI- D IN X 1, VGA X 1, HDMI X 1, DVI-I Out x 1, LAN, with required mounting bracket as per site requirement. as per technical specification etc. as required.
Supply installation testing and commissioning of Video Wall Controller with required components and accessories, It should have Min 4 Inputs to Connect Workstation and 4 Outputs to Connect Monitors in 2X2 Combination, Display and controller should be from same make. as per technical specification etc. as required.
Access Control System Supply, Installation, Testing and Commissioning of Facial Recognition and Mifare Card based Controller cum Reader having following features. RS-485 and RS-232 Interface, Power supply from Door controller or through Separate Adaptor, as per technical specification etc. as required.
Supply, installation, testing and commissioning of Multidoor Controller Panel to integrate with Fire alarm System and control up to 255 door controller as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of Access Control Module License (ACM) having following features, Comprehensive Access Control Management, For Minimum 500 Users, Time, User and Zone Based Access Control, Access Zones, Access Modes and Access Levels, Advanced Access Control Feature like 2-person rule, First in user rule, Antipas Back, Guard Tour, Duress Detection and More, Various Reports Generation, as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of Time Attendance Module License (TAM) having following features, Comprehensive Time Attendance and Leave Management Software Module, For 500 Users, Attendance and Leave Policy Creation, Integration with payroll and HRM, Shift Schedule, Holiday Schedule and Past Adjustment, Manually Attendance Correction, Leave / Tour Application and Approval, Report and Charts Generation, as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of Visitor Management Module License for 500 Users, as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of Drop Bolt Door Lock as per Door Location requirement, as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of Push Button Exit Switch as per Door Location requirement, as per technical specification etc. as required.
Supplying, installation, testing and commissioning of Client Workstation - Industry standard Intel based platform computer system. Intel Core i7 latest generation, 8 GB of RAM DDR3 ,1 TB SATA II hard drive for OS and VMS applications, NVidia card 2 GB graphics card , 1600 x 1200 or higher screen resolution, 1 X 1000Mbps ethernet network interface card ,16x DVD+/- RW Drive alongwith appropriate licenced Operating System, licenced applications suites from OEM and application licences as per the technical specifications etc. as required.
Cable Television Distribution System (Provision Only) Supplying and Laying of Armoured RG 11 TV cable in prelaid conduit as per technical specification etc. as required.
Supplying and Laying of RG 6 TV cable in prelaid conduit as per technical specification etc. as required.
Supplying and Laying of Armoured RG 6 TV cable in prelaid conduit as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of one television point to be done with television outlet socket and box of the APPROVED make, as per technical specification etc. as required.
iBMS Solution Supplying, installation, testing and commissioning of BMS Server - Industry standard Intel based platform, rack mounted, redundancy architecture for critical hardware components, licensed Microsoft Server operating system and requisite user licenses, licensed application suites, 2 x Quad Core Intel® Xeon latest processors or better, 8 GB of RAM, 2 x 1.2 TB of SAS HDDs, minimum 2 additional hard disk drive bays for expansion, 1,280 x 1,024 Display/ video resolution, 2 X 10/100/1000 ethernet network interface card, Video memory 2GB above, RAID support built-in, DirectX 8.1 above and pre-installed DVD-R/W Drive and Appropriate Licensed Operating Systems as per VMS Requirement. as per technical specification etc. as required.. The system shall be provided with 55" Full HD LED monitor for viewing GUI application as per technical specification etc. as required.
Supplying, installation, testing and commissioning of Laser Jet B/W Printer - A4 Size. as per technical specification etc. as required.
Supplying, installation, testing and commissioning of IBMS Server Software suite: Multi Descipline Integrated BMS (IBMS software like HVAC control , Fire Alarm system, Access control system , CCTV monitoring system , ETC). The client license provided shall display actual graphics as represented in the server machine. Shall be capable of interfacing with Bacnet/IP based DDC controllers, Bacnet/IP or modbus RTU 3rd party interface. Complete with Webserver for IBMS interface on Internet / Intranet. License for minimum hard/soft I/Os to be considered as per I/O Summary. Software should have the following Key features: 1. Intitutive graphics dashboard 2. High End Vector & 3D Graphics 3. LDAP user direct integration 4. Software shall be able to communicate with BACnet & Modbus IP simultaneously withour any external hardware like protocol / integration convertor / controller. 5. Mobile Platform: IPAD/ Android Compatible. 6. Display of HTML 5 Pages fromm company intranet or Internet for full smart device compatibility - with NO Java Dependancy in the Browser. 7. Multi parameter trend should be configured. 8. Database supported by software should be either SQL/oracle/db2. Also software should support 128 bit ssl encryption. 9. Can be able to import Auto Cad drawing directly 10. Energy Management & Reporting Tool software for Monitoring Building efficiency & Customization of Energy Management (For 100 Meters) Application that will Communicate with the Main Framework having Capability of Energy Profiling, Energy Mapping, Load Calculations, Predictive Energy Analysis, Energy Spectrum Analysis etc. 11. Tentant Billing Software for BTU Meters over M-BUS for 100 Meters an expandable up to 500 meters.. Note: All required Software with original license competent with BMS software. as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC: INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. Software interface for Secondry Pump VFD Soft Data Integration on Modbus / Bacnet Over IP as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. Software interface for CSU's , FCU's (37 Nos) & Heat Recovery Unit (2 Nos) VFD Soft Data Integration on Modbus / Bacnet Over IP as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. Software interface for Tube Axial fans - Smoke, Fresh Air and Exhaust Evacuation System Soft Data Integration on Modbus / Bacnet Over IP as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC: INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. Software interface for Energy Meter's ( 50 Nos.) Soft Data Integration on Modbus / RTU. as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC: INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. Software interface for BTU Meter's ( 400 Nos.) Soft Data Integration on M-bus. as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. Software interface for UPS's (5 Nos.) Soft Data Integration on Modbus / RTU. as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. Software interface for Breaker's Soft Data Integration on Modbus / Bacnet Over IP it shall include all LT and HT breaker above 64 A rating as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC: INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. Software interface for ELV System (3500 Points) Soft Data Integration on Bacnet Over IP. as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. of Software interface for Elevator, All Lift Control System . as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC: INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. Software interface for Water Meter's ( 2 Nos.) Soft Data Integration on M-bus. as per technical specification etc. as required.
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 24VAC or 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Chiller Plant Room - as per IO Summary and as per technical specification etc. as required. Consider 10% Spare IO for each DDC Panel.
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 24VAC or 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Ceiling Suspended & Fresh Air Handling Unit - as per IO Summary and as per technical specification etc. as required.Consider 10% Spare IO for each DDC Panel.
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 24VAC or 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Heat Recovery Unit - as per IO Summary and as per technical specification etc. as required.Consider 10% Spare IO for each DDC Panel.
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 24VAC or 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Ventillation Fans - INLINE FAN , EXHAUST FANS - PROPELLER, Tube Axial fans - Liftwell Pressurization, Tube Axial fans - Smoke Evacuation System, Dry Scrubber for Kitchen Hooded Exhaust, Air Washer Units for Kitchen, Tube Axial Exhaust Air Fan with Motor - Car Park Basement Ventilation System, Tube Axial Fresh Air Fan with Motor - Car Park Basement Ventilation System, Jet Fans as per IO Summary and as per technical specification etc. as required.Consider 10% Spare IO for each DDC Panel. (Maximum 4 fans per DDC Panel)
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 24VAC or 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Electrical System - as per technical specification etc. as per IO Summary and as per technical specification etc. as required.Consider 10% Spare IO for each DDC Panel.
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 24VAC or 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Plumbing System, Water Tanks - as per IO Summary and as per technical specification etc. as required.Consider 10% Spare IO for each DDC Panel.
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 24VAC or 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Fire Fighting Ststem - as per IO Summary and as per technical specification etc. as required.Consider 10% Spare IO for each DDC Panel.
Supply, installation, testing and commissioning of hand held portable operator terminals.(POT) touch screen type, shall be able to view graphs , alarms , parameters etc These shall be required if the Controllers and Integration Units do not have a built in keypad on the facia . With required connectors etc. - 4inch. as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Outdoor type Ambient Temperature with Humidity Sensor with radiation shield , IP65 rated(Temp Range -30 to +50 °C, RH : 0-100 %). as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Air Differential Pressure switches the for indicating the Blower status in Air able to measure pressure at 100-1000 pascal pressure. as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Air Differential Pressure switches the for indicating the Filter status in Air able to measure pressure at 40-400 pascal pressure. as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Temperature with Humidity Sensor, IP65 rated with RH accuracy 3 %, temp accuracy +_ 0.7 deg (0 to 70 Degree), as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of CO2 Sensor, as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Modulating type Damper Actuator, as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Air Type Differential Pressure Transmitter, as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Water Type Differential Pressure Transmitter, as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Water Type Differential Pressure Switch, as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Immersion Temperature Sensor,IP 65 rated thermister type Range of temp -10 to 50) with Thermowell, as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Ultrasonic type Flow Meter, as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Ultrasonic type Level Transmitter (7 mtr. Depth ), as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Level Switch (5mtr. Depth ), as per technical specification etc. as required.
Supplying, laying , testing and commissioning of 2 Core X 1.0 Sqmm Armoured Shielded Copper Cable (per Hard & Soft I/O points to DDC). as per technical specification etc. as required.
Supplying, laying , testing and commissioning of 4 Core X 1.0 Sqmm Armoured Shielded Copper Cable (per I/O points hard wired to DDC). as per technical specification etc. as required.
Supplying, laying , testing and commissioning of 3 Core X 1.5 Sqmm Armoured Shielded Copper Cable (per DDC to UPS Power Supply). as per technical specification etc. as required.
Lighting Control Solution Supply, Installation, Testing and Commissioning of Dual-Technology Ceiling Mounted Occupancy Sensor with minimum 360-degree coverage pattern, support both Passive infrared (PIR) motion detection & Ultrasonic Motion detection feature or better , Coverage of minimum 2000 sq. Ft. or better, UL Listed as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of 4 Channel DIN Rail Universal Dimmer Module, support minimum 4 channel of forward or reverse phase dimming or better, entire module support minimum 2300 Watts @ 230 Volts AC or better as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of DIN Rail 60 Watt Power Supply or better as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of Single gang 5 Button wired Keypad Engraved as per client requirement with required mounting accessories and backbox, Minimum Five configurable button positions arranged in one column, Auto dimming day/night backlight mode, Built-in 2xdigital/analog input port, for connecting external sensor, as per technical specification etc. as required.
Electric driven fire Hydrant PumpFFTG WORKS Supply, Installation, Testing and Commissioning of Electric driven fire pump (Hydrant Pump) suitable for automatic operation and consisting of following: complete in all respect as required. a) Horizontal, Multi stage multi outlet pump to ensure a minimum pressure of 3.5 kg / sq.cm. at highest and farthest outlet at specified flow of 2850 lpm at 180 m. high head / 100m. low head conforming to IS standards. b) Casing - CI, Impeller - Bronze, Shaft- SS 410, Gland Packing c) Squirrel cage induction motor with suitable HP with synchronous speed , Suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, Conforming to IS standards. d) Common Base plat for Pump and motor and coupling, coupling guard, rubber bellow, foundation bolt and other accessories as required for complete Installation of pump set. e) Provide foundation details complete with anti-vibration arrangement etc.
Electric driven fire pumpSupply, Installation, Testing and Commissioning of Electric driven fire pump (Sprinkler Pump) suitable for automatic operation and consisting of following: complete in all respect as required. a) Horizontal, Multi stage multi outlet pump to ensure a minimum pressure of 3.5 kg / sq.cm. at highest and farthest outlet at specified flow of 2850 lpm at 180 m. high head / 100m. low head conforming to IS standards. b) Casing - CI, Impeller - Bronze, Shaft- SS 410, Gland Packing c) Squirrel cage induction motor with suitable HP with synchronous speed , Suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, Conforming to IS standards. d) Common Base plat for Pump and motor and coupling, coupling guard, rubber bellow, foundation bolt and other accessories as required for complete Installation of pump set. e) Provide foundation details complete with anti-vibration arrangement etc.
Diesel Engine Driven stand by pumpSupply, Installation, Testing and Commissioning of Diesel Engine Driven stand by pump suitable for automatic operation and consisting of following: complete in all respect as required. a) Horizontal, Multi stage multi outlet pump to ensure a minimum pressure of 3.5 kg / sq.cm. at highest and farthest outlet at specified flow of 2850 lpm at 180 m. high head / 100m. low head conforming to IS standards. b) Casing - CI, Impeller - Bronze, Shaft- SS 410, Gland Packing c) Diesel Engine with suitable HP with synchronous speed 1800 rpm, diesel tank, battery,battery cable, exhaust pipe with insulation with all required accessories. d) Common Base plat for Pump and motor and coupling, coupling guard, rubber bellow, foundation bolt and other accessories as required for complete Installation of pump set. e) Provide foundation details complete with anti-vibration arrangement etc.
Electric Driven Jockey PumpSupply, Installation, Testing and Commissioning of Electric Driven Jockey Pump suitable for automatic operation and consisting of following: complete in all respect as required. a) Horizontal, Multi stage multi outlet pump to ensure a minimum pressure of 3.5 kg / sq.cm. at highest and farthest outlet at specified flow of 180 lpm at 180 m. high head / 100m. low head conforming to IS standards. b) Casing - CI, Impeller - Bronze, Shaft- SS 410, Mechanical seal c) Squirrel cage induction motor with suitable HP with synchronous speed , Suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, Conforming to IS standards. d) Common Base plat for Pump and motor and coupling, coupling guard, rubber bellow, foundation bolt and other accessories as required for complete Installation of pump set. e) Provide foundation details complete with anti-vibration arrangement etc.
Electric Water Curtain fire pumpSupply, Installation, Testing and Commissioning of Electric driven Water Curtain fire pump suitable for automatic operation and consisting of following: complete in all respect as required. a) Horizontal end suction back pull out centrifugal pump to ensure a minimum pressure of 3.5 kg / sq.cm. at highest and farthest outlet at specified flow of 2850 lpm at 70 m. head conforming to IS standards. b) Casing - CI, Impeller - Bronze, Shaft- SS 410, Mechanical seal c) Squirrel cage induction motor with suitable HP with synchronous speed , Suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, Conforming to IS standards. d) Common Base plat for Pump and motor and coupling, coupling guard, rubber bellow and other accessories as required for complete Installation of pump set. e) Provide foundation details complete with anti-vibration arrangement etc.
Pressure GaugeSupply, Installation, Testing and Commissioning of 150 mm dia. Pressure Gauge (for all pipes) of range 0 - 25 Kg / cm² Polished Stainless Steel Case with positive seal against weather, moisture & dust, with Glycerine filled, screwed, nipple, isolation valve, U-type stainless steel siphon tube and complete with necessary as required.
Pressure SwitchesSupply, Installation, Testing and Commissioning of Pressure Switches for automation of fire pumps. Pressure switches shall be SPDT type suitable for single phase supply with diaphragm, IP 67 protection as required.
M.S. Pipes of Class C 250 mm dia.Supply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, M.S. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. All fittings up to 50mm shall be forged and above 50mm shall be butt welded. 250 mm dia. (wall thickness 6.3 mm)
M.S. Pipes of Class C200 mm dia.Supply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, M.S. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. All fittings up to 50mm shall be forged and above 50mm shall be butt welded. 200 mm dia. (wall thickness 6.3 mm)
M.S. Pipes of Class C150 mm dia.Supply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, M.S. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. All fittings up to 50mm shall be forged and above 50mm shall be butt welded. 150 mm dia. (wall thickness 6.3 mm)
M.S. Pipes of Class C100 mm dia.Supply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, M.S. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. All fittings up to 50mm shall be forged and above 50mm shall be butt welded. 100 mm dia. (wall thickness 6.3 mm)
M.S. Pipes of Class C80 mm diaSupply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, M.S. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. All fittings up to 50mm shall be forged and above 50mm shall be butt welded. 80 mm dia (wall thickness 6.3 mm)
M.S. Pipes of Class C65 mm dia.Supply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, M.S. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. All fittings up to 50mm shall be forged and above 50mm shall be butt welded. 65 mm dia. (wall thickness 6.3 mm)
M.S. Pipes of Class C50mm diaSupply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, M.S. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. All fittings up to 50mm shall be forged and above 50mm shall be butt welded. 50mm dia (wall thickness 6.3 mm)
M.S. Pipes of Class C40 mm diaSupply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, M.S. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. All fittings up to 50mm shall be forged and above 50mm shall be butt welded. 40 mm dia (wall thickness 6.3 mm)
M.S. Pipes of Class C32mm diaSupply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, M.S. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. All fittings up to 50mm shall be forged and above 50mm shall be butt welded. 32mm dia (wall thickness 6.3 mm)
M.S. Pipes of Class C25mm diaSupply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, M.S. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. All fittings up to 50mm shall be forged and above 50mm shall be butt welded. 25mm dia (wall thickness 6.3 mm)
C.I. Y type StrainerSupply, Installation, Testing and Commissioning of C.I. Y type Strainer with S.S. Screen/SS 304 having 1.2mm perforation with require accessories. 250 mm Dia.
C.I. Sluice valve 250 mm diaSupply, Installation, Testing and Commissioning of C.I. Sluice valve (IS: 14846,PN 16) with flanges, nut bolts, gaskets complete as required. 250 mm dia.
C.I. Sluice valve 200 mm dia.Supply, Installation, Testing and Commissioning of C.I. Sluice valve (IS: 14846,PN 16) with flanges, nut bolts, gaskets complete as required. 200 mm dia.
C.I. Sluice valve 150 mm dia.Supply, Installation, Testing and Commissioning of C.I. Sluice valve (IS: 14846,PN 16) with flanges, nut bolts, gaskets complete as required. 150 mm dia.
C.I. Sluice valve 80 mm dia.Supply, Installation, Testing and Commissioning of C.I. Sluice valve (IS: 14846,PN 16) with flanges, nut bolts, gaskets complete as required. 80 mm dia.
C.I. Sluice valve 65 mm dia.Supply, Installation, Testing and Commissioning of C.I. Sluice valve (IS: 14846,PN 16) with flanges, nut bolts, gaskets complete as required. 65 mm dia.
Cast Steel Gate valve 250 mmSupply, Installation, Testing and Commissioning of Cast Steel Gate valve (BS: 1414, API-600) with flanges, nut bolts, gaskets complete as required. 250 mm dia.
Cast Steel Gate valve 200 mmSupply, Installation, Testing and Commissioning of Cast Steel Gate valve (BS: 1414, API-600) with flanges, nut bolts, gaskets complete as required. 200 mm dia.
Cast Steel Gate valve 150 mmSupply, Installation, Testing and Commissioning of Cast Steel Gate valve (BS: 1414, API-600) with flanges, nut bolts, gaskets complete as required. 150mm dia.
Cast Steel Gate valve 80 mmSupply, Installation, Testing and Commissioning of Cast Steel Gate valve (BS: 1414, API-600) with flanges, nut bolts, gaskets complete as required. 80 mm dia.
Cast Steel Gate valve 65 mmSupply, Installation, Testing and Commissioning of Cast Steel Gate valve (BS: 1414, API-600) with flanges, nut bolts, gaskets complete as required. 65 mm dia.
C.I. Butterfly valve 150 mmSupply, installation, testing and commissioning of C.I. Butterfly valve (PN 25) with flanges, nut bolts, gaskets complete as required. 150 mm dia.
C.I. Butterfly valve 100 mm dia.Supply, installation, testing and commissioning of C.I. Butterfly valve (PN 25) with flanges, nut bolts, gaskets complete as required. 100 mm dia.
C.I. Butterfly valve 80 mm dia.Supply, installation, testing and commissioning of C.I. Butterfly valve (PN 25) with flanges, nut bolts, gaskets complete as required. 80 mm dia.
C.I. Butterfly valve 65 mm dia.Supply, installation, testing and commissioning of C.I. Butterfly valve (PN 25) with flanges, nut bolts, gaskets complete as required. 65 mm dia.
C.I. Butterfly valve 50 mm dia.Supply, installation, testing and commissioning of C.I. Butterfly valve (PN 25) with flanges, nut bolts, gaskets complete as required. 50 mm dia.
Cast iron Dual plate 250 mmSupply, Installation, Testing and Commissioning of Cast iron Dual plate Check valve (PN 25). 250mm Dia
Cast iron Dual plate 200mm DiaSupply, Installation, Testing and Commissioning of Cast iron Dual plate Check valve (PN 25). 200mm Dia
Cast iron Dual plate 150mm DiaSupply, Installation, Testing and Commissioning of Cast iron Dual plate Check valve (PN 25). 150mm Dia
Cast iron Dual plate 65 mm dia.Supply, Installation, Testing and Commissioning of Cast iron Dual plate Check valve (PN 25). 65 mm dia.
Air vesselSupply, Installation, Testing and commissioning of Air vessel of size 450 x 2000 mm long fabricated from 8 mm thick M.S Plate and installed vertically on suitable legs with necessary accessories as required for complete Installation.
Hydrant Valve pressure reducing valvSupply, installation, testing and commissioning S.S. Single Headed Internal Fire Hydrant Valve with pressure reducing valve including accessories, fixing with supports, flanged tapping from wet riser, complete as required as per specification & by the Local Fire Authority.
Fire Hydrant ValveSupply, installation, testing and commissioning S.S. Single Headed External Fire Hydrant Valve including accessories, fixing with supports, flanged tapping from wet riser, orifice plate complete as required as per specification & by the Local Fire Authority.
Fire Hose CabinetSupply, Installation, Testing and Commissioning of Fire Hose Cabinet wall mounting type 18swg (750 mm x 600 mm x 250 mm deep) with required accessories as per specification.
Fire Hose pipeSupply, installation, testing and commissioning non-percolating rubber reinforced lined Fire Hose pipe (as per IS : 636) of 63 mm dia and 1x15 mtrs long. The hose shall be rated for burst pressure of 38 kg/sqcm. Hose shall be complete with ISI marked SS male & female coupling (IS:903) bound as per specification.
SS short branch pipeSupply, Installation, Testing and commissioning of 63 mm dia instantaneous pattern SS short branch pipe, 20 mm dia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete as required by the Local Fire Authority.
First Aid Hose Reel, pressure valveSupply, installation, testing and commissioning of First Aid Hose Reel with pressure reducing valve conforming to IS:884 comprising of hose reel drum, 8 mm shut off nozzle, hose reel tubing type-2 as per IS: 444 of 25 mm dia x 30 mtr. long, painting, fixed wall type with fixing bracket, anchor fastener, bolts & nuts etc. complete as required by Local Fire Authority.
orifice plateSupplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.(For external hydrant & sprinkler tapping line)
forged brass Ball ValveSupply, installation, testing and commissioning of forged brass Ball Valve.(PN 25) 25mm dia
M.S Sand BucketSupply & Installation of 9 ltrs M.S Sand Bucket (4 EA.) with stand. (IS:2546)
Brass Sprinkler test and Drain ValveSupply, Installation, Testing and Commissioning of Brass Sprinkler test and Drain Valve (300 PSI) assembly with all required fittings as per drawing and as directed.(UL listed & FM approved)
Four Way Fire Brigade InletSupply, installation, testing and commissioning of Cast Iron Four Way Fire Brigade Inlet as per IS: 904 having 63 mm dia inlet with blank cap and chain with necessary fittings, flanges, nut bolts etc. complete as required.
C.I Draw-out connectionProviding & fixing C.I Draw-out connection with foot valve with strainer with 2 EA 63 mm dia instantaneous type male couplings complete as per specification/drawings and as directed by Engineer In Charge.
Air Release ValveSupply, Installation, Testing and Commissioning of Gun Metal Air Release Valve with necessary fittings. Size: 25 mm (For Riser)
Pendent Sprinkler 57°C - K-80Supply, Installation, Testing and commissioning of Quartzoid Bulb type Sprinkler Heads. Pendent Sprinkler 57°C - K-80 - standard response - UL listed
Side Wall Type Sprinkler 57°C - K-80Supply, Installation, Testing and commissioning of Side Wall Type Sprinkler 57°C - K-80 - standard response - UL listed
Upright Sprinkler 57°C - K-80Supply, Installation, Testing and commissioning of Upright Sprinkler 57°C - K-80 - standard response - UL listed
Pendent Sprinkler with rossete plateSupply, Installation, Testing and commissioning of Pendent Sprinkler with rossete plate 57°C - K-80 - standard response - UL listed
Pendent Sprinkler with rossete plateSupply, Installation, Testing and commissioning of Pendent Sprinkler with rossete plate 68°C - K-80 - standard response - UL listed
Flexible pipe 700mmProviding, fixing, testing & commissioning UL listed SS corrugated braided Flexible pipe, nominal Inlet by outlet 1"x ½" with required accessories to complete the installation. Size: 700mm
Flexible pipe 1000mm Providing, fixing, testing & commissioning UL listed SS corrugated braided Flexible pipe, nominal Inlet by outlet 1"x ½" with required accessories to complete the installation. Size: 1000mm
Flexible pipe 1200mm Providing, fixing, testing & commissioning UL listed SS corrugated braided Flexible pipe, nominal Inlet by outlet 1"x ½" with required accessories to complete the installation. Size: 1200mm
Installation control valve Providing, fixing, testing & commissioning of Installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the sprinkler system activates, pressure gauges, emergency releases, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of following sizes as required : Size: 150mm dia
Deluge Valve for Water Curtain Supply, Installation, Testing and Commissioning Cast Iron Deluge Valve for Water Curtain system with required isolation valves, accessories & integration with other service. 150 mm Dia
Water Curtain Nozzle Supply, Installation, Testing and commissioning of crome plated brass Water Curtain Nozzle. (K-37 @ 3.5 bar, UL listed)
Flow Indicating Switch 150 mm dia Supply, Installation, Testing and commissioning of Vane type Flow Indicating Switch with fittings, Flanges, nut-bolts, washers etc. as per requirement. (UL listed & FM approved) 150 mm dia.
Flow Indicating Switch 100 mm dia Supply, Installation, Testing and commissioning of Vane type Flow Indicating Switch with fittings, Flanges, nut-bolts, washers etc. as per requirement. (UL listed & FM approved) 100 mm dia.
Flow Indicating Switch 80 mm dia Supply, Installation, Testing and commissioning of Vane type Flow Indicating Switch with fittings, Flanges, nut-bolts, washers etc. as per requirement. (UL listed & FM approved) 80 mm dia.
Flow Indicating Switch 65 mm dia Supply, Installation, Testing and commissioning of Vane type Flow Indicating Switch with fittings, Flanges, nut-bolts, washers etc. as per requirement. (UL listed & FM approved) 65 mm dia.
Carbon Dioxide (Co2) 4.5 kg Supply, installation, testing and commissioning of Carbon Dioxide (Co2) type Fire Extinguisher of 4.5 kg confirm to IS:15683, stored pressure, squeeze type with ISI marked fitted with required accessories including wall suspension brackets.
Carbon Dioxide (Co2) 6.5 kg Supply, installation, testing and commissioning of Carbon Dioxide (Co2) type Fire Extinguisher of 6.5 kg confirm to IS:15683, stored pressure, trolley mounted with ISI marked fitted with required accessories including wall suspension brackets.
ABC type 6 kg stored pressureSupply, installation, testing and commissioning of ABC (MAP 90%) type 6 kg stored pressure, squeeze type confirm to IS:15683, with ISI marked fitted with required accessories including wall suspension brackets.
Clean Agent HCF236faSupply and fixing of Clean Agent HCF236fa, 10 Kg modular type ceiling mounted Fire extinguisher , Stored pressure type with pressure gauge.
2 hrs Fire stop cementSupply, installation, testing and commissioning of 2 hrs Fire stop cement for Fire shaft cut-outs as per specifications.
AUTO GLOW Signage s Providing, fixing AUTO GLOW photo luminescent Signage s as per IS standard in Block / Small Letters on rigid sheet with necessary wall or Ceiling fittings as Specified Sizes: Fire lift: size: 100 X 300mm
In case of Fire, do not use liftProviding, fixing AUTO GLOW photo luminescent Signage s as per IS standard in Block / Small Letters on rigid sheet with necessary wall or Ceiling fittings as Specified Sizes: In case of Fire, do not use lift, use staircase: 200 X 200mm
Fire Equipment : size: 100 X 300mmProviding, fixing AUTO GLOW photo luminescent Signage s as per IS standard in Block / Small Letters on rigid sheet with necessary wall or Ceiling fittings as Specified Sizes: Fire Equipment : size: 100 X 300mm
Floor indication signageProviding, fixing AUTO GLOW photo luminescent Signage s as per IS standard in Block / Small Letters on rigid sheet with necessary wall or Ceiling fittings as Specified Sizes: Floor indication signage : size: 300 X 300mm
Assembly Point 600 X 600mmProviding, fixing AUTO GLOW photo luminescent Signage s as per IS standard in Block / Small Letters on rigid sheet with necessary wall or Ceiling fittings as Specified Sizes: Assembly Point : 600 X 600mm
1200007918C Emergency Escape Plan (297 X 420mm)Providing, fixing AUTO GLOW photo luminescent Signage s as per IS standard in Block / Small Letters on rigid sheet with necessary wall or Ceiling fittings as Specified Sizes: Emergency Escape Plan : A3 (297 X 420mm)
Fire Action : 600 X 450mmProviding, fixing AUTO GLOW photo luminescent Signage s as per IS standard in Block / Small Letters on rigid sheet with necessary wall or Ceiling fittings as Specified Sizes: Fire Action : 600 X 450mm
Emergency Egress RoutesSupply Of Self Contained Rechargeable SWGS Emergency Egress Routes Lighting With the 1X 3 W LED Lamp. The equipment Shall Surface/hanging mounted with all require Accessories with requirement for the Fire and Safety code of practice with 3 Hours backup. Nominal Input Voltage 230 +-10 % to 240V A.C. +-10 % 50 Hz +-10 % as specified in specification. (Size:300 x 180mm)
Design, Supply, installation, tesing and commissioning of UL listed and NFPA 2010 compliant Condensed Aerosol based fire supression system for Battery rooms. the system shall be complete with Required Aerosol gas units considering class C fire hazard, activation sensors & accessories, Gas release panel, Smoke detectors, hooter, abort switch, manual release switch, Electrical supply cut off contactor, battery back, necessry alarm and activation cabling etc as compete system with related civil works as per technical specification. FCC and BMS room : Area: 50 Sq.mtr Ht: 3.5 mtr
Design, supply, installation, testing andcommissioning of CO2 based gaseous fire suppression system for Electrical panel. The system shall be complete with CO2 cylinder fitted with High pressure valve with necessary fittings, Mounting accessories, gas weight sensors, Heat detection tube, Discharge pressure switch with adaptor, Master control panel with Audio visual alarm ( 1 panel per room - each panel one zone) FRLS cables etc. as complete system for following sizing of electrical panel per technical specification. The system shall be as per NFPA 12. Following are panel diamensioning in mm in L x W x H format. HT panel : 5000x1200x2200 (mm)
Design, supply, installation, testing andcommissioning of CO2 based gaseous fire suppression system for Electrical panel. The system shall be complete with CO2 cylinder fitted with High pressure valve with necessary fittings, Mounting accessories, gas weight sensors, Heat detection tube, Discharge pressure switch with adaptor, Master control panel with Audio visual alarm ( 1 panel per room - each panel one zone) FRLS cables etc. as complete system for following sizing of electrical panel per technical specification. The system shall be as per NFPA 12. Following are panel diamensioning in mm in L x W x H format. Main LT panel 2: 5000x1200x2200 (mm)
GARBAGE CHUTEGARBAGE CHUTE SITC of THROAT PIECE: -Manufacture and febricated from SS304 Sheet, rolled & seam welded for water tight joint. Throat welded with TIG welding, Supported by hot dip galvanized structural steel brackets, anchor fastened to available RCC structure anf flush to adjsent wall. Scope Includes, 1.2 Mtrs. height Throat Piece with beaded telescopic joint, Cable, Sch40 pipes, cleaning sprinkler ailed fittings, pipe 12mtr. Length for Sanitation. Cable & pipe bracket, floor level, bracket, Anchor fastener, Clamp band ring, Hardware as per per floor for mixed soil waste and mixed recyclables waste,as per site incharge instruction.
1200008059C SITC of Intake HoppersSITC of Intake Hoppers :-Electric Strike type Auto closing Bottom pivoted, Top opening, Self- Latching, 90 Min. Fire rated certified by UL (Underwriter s Laboratories, USA, as per UL 10B with Interlocking arrangement for One User at a time. The controllers for interlocking system needs is certified by UL- USA (Horizon Certified-NRNT2.E317138), (frame 2mm thick & double skin shutter 1.5mm thick with Rockwool as Infill.) These Intake hoppers are as per BS 1703:2005 and with following specifications.:- 1. Material – Stainless Steel SS 304 2. Frame – 2 mm Thickness 3. Shutter -1.5 mm Thickness, Double Skin, with infill as Rockwool 4. Fire Rating – UL Labeled, 90 min fire rated with max temperature rise of 250 F as per UL Label 10B Standard. 5. Closing – Self Closing, Noiseless. 6. Operation – By using UL Listed Controller, Allowing only one user at a time. All doors are locked at any given point of time with Green “Ready†indicator. User has to press button to operate chute. When one person operates chute, all other floors shall remain locked with Red “Busy†Indicator. 7. All hoppers shall remain locked with Red “Busy†indicator during cleaning operation or Maintenance. 8.Per Floor for Mixed solid waste – practically all types of household kitchen waste, cafeteria and other F&B waste like bones, rice, cut vegetables, food scraps, disposable nappies, food wrapping, etc. per floor. 9. Per Floor for Mixed recyclables – small metal cans, plastic bottles, papers, food waste, etc. .
1200008060C CHUTE Intermediates PiecesSITC of CHUTE Intermediates Pieces per floor:- as per conform to either BS 1703:2005, Clause 6, or NFPA 82, 6.3.2. SITC as per floor to floor height with beaded. telescopic joint. Clamp band ring, Hardware, Clamps are per length, Scd40 and 80 pipes & fitting with connect with intake hopper or fabrication etc. Complete as per all aspect as per site requirement. or as per site in charge.
1200008061C Intermediate Pieces - 2mmIntermediate Pieces - 2mm (Discharges End)
1200008062C Sanitation Unit- 2â€NBSanitation Unit- 2â€NB SITC Sanitation Unit: - provided Interlocking System Control Panel, is for combination of Interlocking as well as Cleaning Control Panel, as per IP 55 powder/paint coating. It is provided with potential force contact for fire alarm, thus in case of fire, chute cannot be operative. Fire interlocks provided. In case of maintenance or fault in intake hopper, it is isolated from system and Rest of chute system shall be working. Master control panel shall be UL listed per 508A. Master control panel is provided with RS485 port to connect with BMS
1200008063C Full Dia Vent + Exhaust PieceFull Dia Vent + Exhaust Piece SITC of CHUTE Exhaust Piece: - Designed to provide Min.20 /40. Air Changes per Hour (ACH) to control the Odour in the chute, by using roof extractor fan with steel housing of same material of the chute. It is controlled by Timer based controller having (e.g. 20 Min. ON & 10 min. OFF ) running 24 hours to remove the Odour in the chute. Scope Includes Following: - Easy removal arrangement for exhaust fan, “9" exhaust fan, Enclosure, control panel, cabling, clamp band ring, hardware, Vent with bird netting. SITC of Full Dia Explosion / Ventilation Vent with flashing curb: - Full Dia explosion Vent to be provided as per NFPA82 requirement which also should be designed to release Pressure in case of explosion & in normal conditions should be a vent. Vent should be full Dia with Bird Netting and Weather cowl.
1200008064C GARBAGE Master Control PanelSITC of Master Control Panel: - Control panel provide for interlocking hoppers to facilitate one used at a time. Interlocking System Control Panel, is for combination of Interlocking as well as Cleaning and Sanetizing, as per IP 55 powder/paint coating. It is provided with potential force contact for fire alarm, thus in case of fire, chute cannot be operative. Fire interlocks provided. In case of maintenance or fault in intake hopper, it is isolated from system and Rest of chute system shall be working. Master control panel shall be UL listed per 508A. Master control panel is provided with RS485 port to connect with BMS.
1200008065C Fire SprinklersFire Sprinklers
1200008066C SITC of Brush Cleaning SystemSITC of Brush Cleaning System Full dia Hard Nylon Bristel brush up and down operation inside the chute for cleaning internal surface of chute. Operation by geared motor with Double safety for every parameter. 0.5 Hp, 3 Ph, PLC based master control panel 6 Inputs 6 Out Puts. Water sprinkler to operate while operation of brush is ON.
SITC of Crossflow heat exchanger without coil double skin construction FOR FRESH AIR & EXHAUST AIR SYSTEM. The unit shall comprise of filter section, heat recovery unit, inlets and outlets for fresh air / exhaust air , fan section with DIDW fan with motor and drive package. The unit shall be installed nearer to toilet ceiling and interconnected in a manner so as to receive part return air thru public area which shall be passed through HRU and transfer sensible and latent cooling to incoming fresh air. The treated fresh air shall let into the Return Air path of IDU / Fresh Air ports of Standard IDUs and hot exhaust air shall be released to ambient. The exhaust section of the unit shall be provided with motor actuated GSS damper duly interlocked with the fan. Minimum sensible and latent heat transfer efficiency of heat recovery unit shall be 70%. The Noise level shall not be < 45 dB at 1 meter distance with inbuilt remote controller system. Design conditions shall be as follows Fresh Air at the Inlet of HRU Summer Conditions DB 110 deg F WB 73 deg F Monsoon Conditions DB 89.1 deg F WB 82.8 deg F Exhaust Air Temp. at the Inlet of HRU Thermal efficiency minimum 70% in summer. 2400 cfm Fresh Air / 2400 cfm Exhaust
SITC of Crossflow heat exchanger without coil double skin construction FOR FRESH AIR & EXHAUST AIR SYSTEM. The unit shall comprise of filter section, heat recovery unit, inlets and outlets for fresh air / exhaust air , fan section with DIDW fan with motor and drive package. The unit shall be installed nearer to toilet ceiling and interconnected in a manner so as to receive part return air thru public area which shall be passed through HRU and transfer sensible and latent cooling to incoming fresh air. The treated fresh air shall let into the Return Air path of IDU / Fresh Air ports of Standard IDUs and hot exhaust air shall be released to ambient. The exhaust section of the unit shall be provided with motor actuated GSS damper duly interlocked with the fan. Minimum sensible and latent heat transfer efficiency of heat recovery unit shall be 70%. The Noise level shall not be < 45 dB at 1 meter distance with inbuilt remote controller system. Design conditions shall be as follows Fresh Air at the Inlet of HRU Summer Conditions DB 110 deg F WB 73 deg F Monsoon Conditions DB 89.1 deg F WB 82.8 deg F Exhaust Air Temp. at the Inlet of HRU Thermal efficiency minimum 70% in summer. 1800 cfm Fresh Air / 1800 cfm Exhaust
P & F 900 x 900 mm CI Side Manhole with Frame Supplying and fixing C.I. side Manhole with frame (medium duty) 900 mm x 900 mm.
SITC of Sewage sump Pump 15 m3/hr & 30 m Head Supply, installation, testing and commissioning of submersible type SEWAGE PUMP having SS casing & body Dynamically Balanced AISI 304 stainless steel shaft running in ball bearing on both ends and protected by Bronze shaft sleeves. Pumps shall be fitted with mechanical seals, 2900 RPM, 415 volts, 50 cycles Ac 3 phase Motor should be rated for +/- 10% voltage fluctuation of standard 415 volts including all relevant accessories for complete installation and providing probe level control with cabling and should be oil/ water cooled, PLC panel for providing control on BMS with RS 485 port and should be modbus enabled etc. as per technical specification & direction of EIC. Capacity: 20 m3/hr & 25 m Head - Basement Sewage Sump (1W + 1S) Solid Handling: 10-12 mm
Design, supply, installation, testing andcommissioning of CO2 based gaseous fire suppression system for Electrical panel. The system shall be complete with CO2 cylinder fitted with High pressure valve with necessary fittings, Mounting accessories, gas weight sensors, Heat detection tube, Discharge pressure switch with adaptor, Master control panel with Audio visual alarm ( 1 panel per room - each panel one zone) FRLS cables etc. as complete system for following sizing of electrical panel per technical specification. The system shall be as per NFPA 12. Following are panel diamensioning in mm in L x W x H format. Main LT panel 2: 5000x1200x2200 (mm)
Design, supply, installation, testing andcommissioning of CO2 based gaseous fire suppression system for Electrical panel. The system shall be complete with CO2 cylinder fitted with High pressure valve with necessary fittings, Mounting accessories, gas weight sensors, Heat detection tube, Discharge pressure switch with adaptor, Master control panel with Audio visual alarm ( 1 panel per room - each panel one zone) FRLS cables etc. as complete system for following sizing of electrical panel per technical specification. The system shall be as per NFPA 12. Following are panel diamensioning in mm in L x W x H format. FFTG Panel: 2500x900x2200 (mm)
Design, supply, installation, testing andcommissioning of CO2 based gaseous fire suppression system for Electrical panel. The system shall be complete with CO2 cylinder fitted with High pressure valve with necessary fittings, Mounting accessories, gas weight sensors, Heat detection tube, Discharge pressure switch with adaptor, Master control panel with Audio visual alarm ( 1 panel per room - each panel one zone) FRLS cables etc. as complete system for following sizing of electrical panel per technical specification. The system shall be as per NFPA 12. Following are panel diamensioning in mm in L x W x H format. LIFT panel: 3000x500x2200 (mm)
Provide and installation of Acrylic Firestop Sealant in services passing through fire rated walls made of concrete, masonry, metal, gypsum construction to provide up to 2 hours insulation(140x50 inrock RB Slab) and integrity in accordance to EN 1366-3 / ASTM E 814 standards. Sealant to provide sufficient water and gas tight seal apart from providing an airborne sound transmission reduction (STC of 65) and shall be tested for sound insulation. All installations to be in full accordance with the manufacturer recomendation. Considering 50mm annular gap around services maximum. (Fisher RFS640 or equivalent of 3M / Arma protect)
Provide and Installation of intumescent firestop sealant for insulated services passing through fire rated floors made of concrete, masonry,fire rated gypsum construction to provide up to 2 hours fire rating and integrity in accordance to EN 1366-3 / ASTM E 814 standards (mortar). Considering 50mm annular gap around services maximum. (Fisher FFSC or equivalent of 3M / Arma protect)
Dineshchandra R Agrawal Infracon Pvt. Ltd.
Capacite Infraprojects Limited
US Dollar
European Euro
Japanese yen
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid