Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L1 | Accepted-AOC RATES QUOTED ARE REASONABLE | |
| 2 | L2₹12.1 L+₹2.1 L (21.3%)Rejected-Finance | L2 | Rejected-Finance RATES QUOTED ARE HIGHER THAN L1 | |
| 3 | L3₹13.7 L+₹3.7 L (37.6%)Rejected-Finance C 150 ADG P CHENNAI | L3 | Rejected-Finance RATES QUOTED ARE HIGHER THAN L1 | |
| 4 | L4₹13.8 L+₹3.8 L (38.5%)Rejected-Finance | L4 | Rejected-Finance RATES QUOTED ARE HIGHER THAN L1 | |
| 5 | L5₹14.2 L+₹4.3 L (42.9%)Rejected-Finance NO 17 PETER GNANA PRAKASAM NAGAR MARIYAMMAN KOVIL PO THANJAVUR 611501 | 611501 | L5 | Rejected-Finance RATES QUOTED ARE HIGHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
23 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER AIRFORCE THANJAVUR
GARRISON ENGINEER AIRFORCE PUDUKKOTTAI ROAD THANJAVUR
REPLACEMENT OF BUILDINGS SECURITY LIGHTS IN TECHNICAL AREA AND DOMESTIC AREA AT AIRFORCE STATION THANJAVUR.
2020_MES_406449_1
8786/E8
Open Tender
Electrical Maintenance Service
Item Rate
330 days
THANJAVUR
AS PER NIT
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER AIRFORCE THANJAVUR
₹30,000
Yes
11 May 2021
23 Dec 2020
25 Jan 2021
23 Dec 2020
23 Jan 2021
7 Jan 2021
60 days
Amount
M&L for point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable working voltage 1100 volts grade conforming to IS-694 with multistranded copper conductor in including PVC rigid non metallic 25 mm PVC casing caping (double Lock) including PVC polycarbonate/PVC/rectangular block/box of suitable size fixed by means of brass machine screw and cap washer including size 1.5 sqmm (nominal cross sectional area PVC insulated unsheathed single core multistranded copper conductor cable as earth continuity conductor connected to main switches /DBs or common earth dolly complete all as specified and as directed. Make of cable-Havells/Finolex/plaza,
S&F Switch piano flush button, white/ivory finish, 5/6 amps, single pole, one way complete all as specified and as directed.
S&F Ceiling rose, surface Bakelite, large type, 220/240 volts, three terminals, white/ivory finish complete all as specified and directed.
Supply and fix in replacement LED building security light 15 watt model ENDURA PEARL new generation energy saving and environmental friendly long life LED strret lights made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact of IK07 complete all as per Havells cat Part No :- ENDURAPEARLSL15WLED757SASYTOPCMP or equivalent in CG/Philips.
Supply and fix in replacement of LED, building security light 20 watt model ENDURA PEARL new generation energy saving and environmental friendly long life LED street lights made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact of IK07 complete all as per Havells cat Part No :- ENDURAPEARLSL20WLED757SASYTOPCMP or equivalent in CG/Philips.
Supply and fix in replacement of LED, building security light 25 watt model ENDURA PEARL new generation energy saving and environmental friendly long life LED street lights made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact of IK07 complete all as per Havells cat Part No :- ENDURAPEARLSL25WLED757SASYTOPCMP or equivalent in CG/Philips.
Supply and fix in replacement of LED building security light 30 watt model ENDURA PEARL new generation energy saving and environmental friendly long life LED street lights made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact of IK07 complete all as per Havells cat Part No :- ENDURAPEARLSL30WLED757SASYTOPCMP or equivalent in CG/Philips.
Supply and fix in replacement of LED building security light 30 watt model ENDURA CITYLITE PLATINUM PLUS new generation energy saving and environmental friendly long life LED strret lights made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact of IK07 complete all as per Havells cat Part No :- ENDURACITYLITEPLATPLUSSL35WLED757SASYBOPC or equivalent in CG/Philips.
Supply and fix in replacement of GI pipe bracket made out of medium grade 32 mm bore GI tubing duly bend to the required shape length of the bracket shall be not less than 1.5 m including MS flat iron clamps, nuts, bolts and washers for fixing of bracket on pole complete all as specified and directed.
Supplying and fixing in replacement of HEXA 10W IP66 environmental friendly, ultra modern energy saving surface mounted decorative hexagonal bulk head back lit LED luminaire comprising of high brightness LEDs and making necessary connections complete all as specified and as directed.Make Havells Cat Part. No HEXAFT10WLED857SSYMBOPC or Equivalent in Philips & CG.
Supply, Laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 10 sqmm 2 core with all fixing & connecting accessories including taking down old unserviceable cable. Make: Havell’s / Polycab / Finolex)
All as per Item No 11 here-in-before but 16 sqmm 2 core (Make: Polycab/Havell’s/Plaza)
All as per Item No 11 here-in-before but 10 sqmm 4 core (Make: Polycab/Havell’s/Plaza)
Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / laying under ground electric cable or for pole etc complete all as specified and as directed.
Returning and filling in two parts (i) using riddled soil obtain from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and directed. Note:- Excavated soil shall be riddled by using sieve to separate composite partricles etc as per IS 1255 1983 and refilling in trenches as in cable cushioning.
Removing surplus soils to a distance not exceeding 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point all complete as specified and as directed.
Supply and laying Bricks, sub class 'B' old size bricks, laid flat dry with width of the bricks laid to the axis of the cable all complete as specified and as directed.
Supply and laying in replacement for 10 sqmm one twin core flat or circular 1100 volt grade heavy duty cable insulated stranded aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed complete all as specified and directed. Make:- Havells / Polycab / Plaza
Supply and fix in replacement junction box of size 200mm x 150mm x 100mm made out of FRP with double stud hinged door locking including fixing hardware on Steel tubular pole or PCC pole in and including MCB 6 amps - 1 Nos within rail for mounting of MCB including suitable connector for looping duly sealed with rubber plugs complete all as specified and directed by Enge In Charge. Make Sintex/Finolex/Hansel
M&L for sub main wiring with 2 run of 2.5 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core flame retardant cable (FR) of working voltage 1100 volts grade with stranded copper conductor including one run of 1.5 Sqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FR) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn with and including 20 mm dia PVC rigid non- metallic conduit including flexible PVC pipe at starting and finishing point after and including taking down / dismantling old sub main wiring including old conduit etc of any description complete all as specified and as directed. NOTE : (i) Two run of submain wiring cable alongwith one run of earth wire and one run of PVC rigid non metallic conduit shall be measured as one length). (Make:- Plaza / Havells / Polycab / Finolex)
SHAPE MAKER
S.RAMACHANDRAN
POWER TECH ENTERPRISES
M/S. SRI RAMANUJA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .