Loading…
Loading…
Tender Value
₹42.8 Cr
EMD Value
₹42.8 L
Closing Date
29 Apr 2026, 6:00 pmClosed
Superintending Engineer, PIU, Zone-6, Vadodara.
Construction of 100 bedded sub district hospital Building With Compound Wall, R.C.C. Road, M.G.P.S. & Fire at Village. : Savli. Ta. Savli Dist. Vadodara.
290983
2025-26/166/02
Open
Civil Works - Buildings
Vadodara
1 document required · 1 mandatory
₹24,000
PIU-General Fund A/c 11-114
₹42.8 L
29 Mar 2026
29 Mar 2026
29 Mar 2026
29 Apr 2026
29 Mar 2026
Name of Work :-
at Village. : Savli. Ta. Savli Dist. Vadodara.
Memorandom showing items of works to be carried out
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Excavation for foundation up to 1.5 mt. depth including sorting out and stacking of useful Rupees One Hundred
1 7161.82 Cmt materials and disposing off the excavated stuff upto any lead & lift (A) Loose or soft soil 120.01 Twenty and One Paisas Cmt
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and Rupees One Hundred
2 5673.16 Cmt stacking of useful materials and disposing off theexcavated stuff upto 50 Meter lead.(A) 133.05 Thirty Three and Five Cmt
Loose or soft soil Paisas Only
Excavation for foundation for depth from 3.0 m to 5.0 m including sorting out and Rupees One Hundred
3 5200.00 Cmt stacking of useful materials and disposing off the excavated stuff upto 50 Meter 146.09 Forty Six and Nine Paisas Cmt
lead.(A) Loose or soft soil Only
Excavation for foundation for depth from 5.0 m to 6.0 m including sorting out and Rupees One Hundred
4 902.00 Cmt stacking of useful materials and disposing off the excavated stuff upto 50 Meter 167.73 Sixty Seven and Seventy Cmt
lead.(A) Loose or soft soil ,Extra for additional depth more than 5.0 m Three Paisas Only
Filling available excavated earth (excluding rock)in trenches, plinth,sides of foundations
Rupees One Hundred
etc. in layers not exceeding 20 cm. in depth consolidation each deposited layer by
5 13404.04 Cmt 133.65 Thirty Three and Sixty Cmt
ramming and watering.
Five Paisas Only
Providing Filling in Sunk Portion with cinder of best approved quality including watering Rupees Three Hundred
6 93.00 Cmt ,ramming consolidation and dressing etc. complete as directed in toilet and bath sunken 335.91 Thirty Five and Ninety Cmt
area at all floor up to all lead and lif One Paisas Only
Filling in foundation and plinth with murrum or selected soil in layers of 20cm thickness Rupees Two Hundred
7 20905.00 Cmt including watering ramming and consolidating etc. complete 296.29 Ninety Six and Twenty Cmt
Nine Paisas Only
Filling in plinth with sand under floors including watering ramming, consolidating and Rupees Four Hundred
8 557.00 Cmt dressing complete 471.69 Seventy One and Sixty Cmt
Nine Paisas Only
Applying general insecticide pest control treatment to floors, cupboards etc including
labour materials etc. complete. Using Imidacloprid 30.5 SCas Per IS 6313 part II( (0.075%
Rupees Forty Six and
9 3552.00 Smt concentration by mass) is recommended 10.5ml chemical diluted with 5 liters of water 46.95 Smt
Ninety Five Paisas Only
application 0.5 litre chemical /Sqm of surface is recommended as per I.S.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Provdg. & laying cement concrete 1:2:4 (1cement:2 corse sand :4 hand broken stone
Rupees Three Thousand
aggregate 20 mm nominal size) and curing complete including cost of form work in (A)
10 2275.74 Cmt 3656.13 Six Hundred Fifty Six and Cmt
Foundation and plinth
Thirteen Paisas Only
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Five Thousand
etc. propping and centering below supporting floor to ceiling and removal of the same for Two Hundred Seventy
in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of Two and Forty Seven
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc & Paisas Only
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement. (No extra will be paid in
variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in: (A) Footing Design Mix
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Six Thousand
etc. propping and centering below supporting floor to ceiling and removal of the same for Two Hundred Forty Eight
in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of and Forty Four Paisas
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc & Only
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement. (No extra will be paid in
variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in: (C) RCC Floor Beam Plinth or Tie beam
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping
etc. propping and centering below supporting floor to ceiling and removal of the same for Rupees Seven Thousand
13 199.00 Cmt in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of 7514.14 Five Hundred Fourteen Cmt
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc & and Fourteen Paisas Only
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement.
(No extra will be paid in variation of cement level, minimum cement level will be as per IS
456) for reinforced concrete work in: Up to Plinth Level.(C) Column
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Six Thousand
etc. propping and centering below supporting floor to ceiling and removal of the same for Eight Hundred Seventy
in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of Seven and Nine Paisas
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc & Only
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement. (No extra will be paid in
variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in: (C) RCC Coping (Design Mix)
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping
etc. propping and centering below supporting floor to ceiling and removal of the same for Rupees Seven Thousand
15 184.00 Cmt in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of 7514.14 Five Hundred Fourteen Cmt
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc & and Fourteen Paisas Only
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement.
(No extra will be paid in variation of cement level, minimum cement level will be as per IS
456) for reinforced concrete work in: Above Plinth Level.
(A) Column (i) Ground Floor Design Mix
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping
etc. propping and centering below supporting floor to ceiling and removal of the same for Rupees Seven Thousand
16 182.00 Cmt in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of 7554.08 Five Hundred Fifty Four Cmt
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc & and Eight Paisas Only
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement.
(No extra will be paid in variation of cement level, minimum cement level will be as per IS
456) for reinforced concrete work in: : Above Plinth Level.
(A) Column (i) FIRST Floor Design Mix
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Seven Thousand
etc. propping and centering below supporting floor to ceiling and removal of the same for Five Hundred Ninety
17 182.00 Cmt in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of 7594.03 Cmt
Four and Three Paisas
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc & Only
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement.
(No extra will be paid in variation of cement level, minimum cement level will be as per IS
456) for reinforced concrete work in: : Above Plinth Level.
(A) Column (i) SECOND Floor Design Mix
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Seven Thousand
etc. propping and centering below supporting floor to ceiling and removal of the same for Six Hundred Thirty Three
18 70.00 Cmt in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of 7633.97 Cmt
and Ninety Seven Paisas
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc & Only
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement.
(No extra will be paid in variation of cement level, minimum cement level will be as per IS
456) for reinforced concrete work in: : Above Plinth Level.
(A) Column (i) Terrace Floor Design Mix
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Eight Thousand
etc. propping and centering below supporting floor to ceiling and removal of the same for Two Hundred Forty Four
in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of and Eighty One Paisas
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc & Only
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement. (No extra will be paid in
variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in: (C) RCC Lintel, sill and Mullians Bands i) Ground Floor (Design Mix)
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Eight Thousand
etc. propping and centering below supporting floor to ceiling and removal of the same for Two Hundred Eighty
in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of Four and Seventy Six
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc & Paisas Only
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement. (No extra will be paid in
variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in: (C) RCC Lintel, sill and Mullians Bands i) First Floor (Design Mix)
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Eight Thousand
etc. propping and centering below supporting floor to ceiling and removal of the same for Three Hundred Twenty
in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of Four and Seventy Paisas
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc & Only
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement. (No extra will be paid in
variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in: (C) RCC Lintel, sill and Mullians Bands i) Second Floor (Design Mix)
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Eight Thousand
etc. propping and centering below supporting floor to ceiling and removal of the same for Three Hundred Sixty
in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of Four and Sixty Five
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc & Paisas Only
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement. (No extra will be paid in
variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in: (C) RCC Lintel, sill and Mullians Bands i) Terrace Floor (Design Mix)
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Six Thousand
etc. propping and centering below supporting floor to ceiling and removal of the same for Five Hundred Ninety
in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of Nine and Sixty Seven
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc & Paisas Only
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement. (No extra will be paid in
variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in: (C) RCC For Basement & Ground Floor Slab Beam
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Six Thousand
etc. propping and centering below supporting floor to ceiling and removal of the same for Six Hundred Thirty Nine
in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of and Sixty Two Paisas
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc & Only
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement. (No extra will be paid in
variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in: (C) RCC First Floor Slab Beam
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Six Thousand
etc. propping and centering below supporting floor to ceiling and removal of the same for Six Hundred Seventy
in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of Nine and Fifty Six Paisas
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc & Only
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement. (No extra will be paid in
variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in: (C) RCC Second Floor Slab Beam
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Six Thousand
26 46.00 Cmt etc. propping and centering below supporting floor to ceiling and removal of the same for 6719.51 Seven Hundred Nineteen Cmt
in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of and Fifty One Paisas Only
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc &
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement. (No extra will be paid in
variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in: (C) RCC Terrace Floor Slab Beam
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using Exposed cement concrete work using cement content as per approved Design
Mix manufactured in fully automatic batching plant and transported to site of work in
transit mixer for any lead having continuous agitated mixer, manufactured as per mix
design of specified grade for reinforced cement concrete work including pumping of
batching plant from transit mixer to site of laying, cost of water tight Centering
shuttering by using 18 mm thick water proof ply with Exposed work in centring,
shuttering & Providing formwork of steel cup lock system including centring shuttering Rupees Seven Thousand
strutting and propping etc. propping and centering below supporting floor to ceiling and Two Hundred Thirty Nine
removal of the same for in situ reinforced concrete and plain concrete work in flat and Eighty Two Paisas
surfaces such as soffits of suspended floors slabs Landings walls, Fins and beams, column Only
and the like, floors etc & sides and soffits of beams, Haunching cantilevers Girders, using
grouting if required, admixture in recommended proposition as per IS:9103 to
accelerated, retard, setting of concrete, improve workability as per direction of engineer
in charge and approved , rates includes all heights Up to 4.50 mt, excluding reinforcement.
(No extra will be paid in variation of cement level, minimum cement level will be as per IS
456) for reinforced concrete work in: (C) RCC Weathershed Ground Floor
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using Exposed cement concrete work using cement content as per approved Design
Mix manufactured in fully automatic batching plant and transported to site of work in
transit mixer for any lead having continuous agitated mixer, manufactured as per mix
design of specified grade for reinforced cement concrete work including pumping of
batching plant from transit mixer to site of laying, cost of water tight Centering
shuttering by using 18 mm thick water proof ply with Exposed work in centring,
shuttering & Providing formwork of steel cup lock system including centring shuttering Rupees Seven Thousand
strutting and propping etc. propping and centering below supporting floor to ceiling and Two Hundred Seventy
removal of the same for in situ reinforced concrete and plain concrete work in flat Nine and Seventy Seven
surfaces such as soffits of suspended floors slabs Landings walls, Fins and beams, column Paisas Only
and the like, floors etc & sides and soffits of beams, Haunching cantilevers Girders, using
grouting if required, admixture in recommended proposition as per IS:9103 to
accelerated, retard, setting of concrete, improve workability as per direction of engineer
in charge and approved , rates includes all heights Up to 4.50 mt, excluding reinforcement.
(No extra will be paid in variation of cement level, minimum cement level will be as per IS
456) for reinforced concrete work in: (C) RCC Weathershed First Floor
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using Exposed cement concrete work using cement content as per approved Design
Mix manufactured in fully automatic batching plant and transported to site of work in
transit mixer for any lead having continuous agitated mixer, manufactured as per mix
design of specified grade for reinforced cement concrete work including pumping of
batching plant from transit mixer to site of laying, cost of water tight Centering
shuttering by using 18 mm thick water proof ply with Exposed work in centring,
shuttering & Providing formwork of steel cup lock system including centring shuttering Rupees Seven Thousand
strutting and propping etc. propping and centering below supporting floor to ceiling and Three Hundred Nineteen
removal of the same for in situ reinforced concrete and plain concrete work in flat and Seventy One Paisas
surfaces such as soffits of suspended floors slabs Landings walls, Fins and beams, column Only
and the like, floors etc & sides and soffits of beams, Haunching cantilevers Girders, using
grouting if required, admixture in recommended proposition as per IS:9103 to
accelerated, retard, setting of concrete, improve workability as per direction of engineer
in charge and approved , rates includes all heights Up to 4.50 mt, excluding reinforcement.
(No extra will be paid in variation of cement level, minimum cement level will be as per IS
456) for reinforced concrete work in: (C) RCC Weathershed Second Floor
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using Exposed cement concrete work using cement content as per approved Design
Mix manufactured in fully automatic batching plant and transported to site of work in
transit mixer for any lead having continuous agitated mixer, manufactured as per mix
design of specified grade for reinforced cement concrete work including pumping of
batching plant from transit mixer to site of laying, cost of water tight Centering
shuttering by using 18 mm thick water proof ply with Exposed work in centring,
shuttering & Providing formwork of steel cup lock system including centring shuttering
Rupees Seven Thousand
strutting and propping etc. propping and centering below supporting floor to ceiling and
30 2.00 Cmt 7359.66 Three Hundred Fifty Nine Cmt
removal of the same for in situ reinforced concrete and plain concrete work in flat
and Sixty Six Paisas Only
surfaces such as soffits of suspended floors slabs Landings walls, Fins and beams, column
and the like, floors etc & sides and soffits of beams, Haunching cantilevers Girders, using
grouting if required, admixture in recommended proposition as per IS:9103 to
accelerated, retard, setting of concrete, improve workability as per direction of engineer
in charge and approved , rates includes all heights Up to 4.50 mt, excluding reinforcement.
(No extra will be paid in variation of cement level, minimum cement level will be as per IS
456) for reinforced concrete work in: (C) RCC Weathershed Terrace Floor
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Seven Thousand
31 391.00 Cmt etc. propping and centering below supporting floor to ceiling and removal of the same for 7548.80 Five Hundred Forty Eight Cmt
in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of and Eighty Paisas Only
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc &
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement. (No extra will be paid in
variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in: (C) Basement Slab (Design Mix)
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Seven Thousand
32 419.00 Cmt etc. propping and centering below supporting floor to ceiling and removal of the same for 7548.80 Five Hundred Forty Eight Cmt
in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of and Eighty Paisas Only
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc &
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement. (No extra will be paid in
variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in: (C) Ground Floor Slab (Design Mix)
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Seven Thousand
etc. propping and centering below supporting floor to ceiling and removal of the same for Five Hundred Eighty
in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of Eight and Seventy Five
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc & Paisas Only
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement. (No extra will be paid in
variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in: (C) First Floor Slab (Design Mix)
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Seven Thousand
etc. propping and centering below supporting floor to ceiling and removal of the same for Six Hundred Twenty
in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of Eight and Sixty Nine
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc & Paisas Only
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement. (No extra will be paid in
variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in: (C) Second Floor Slab (Design Mix)
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Seven Thousand
etc. propping and centering below supporting floor to ceiling and removal of the same for Six Hundred Sixty Eight
in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of and Sixty Four Paisas
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc & Only
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement. (No extra will be paid in
variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in: (C) Terrace Slab (Design Mix)
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Seven Thousand
36 51.00 Cmt etc. propping and centering below supporting floor to ceiling and removal of the same for 7453.66 Four Hundred Fifty Three Cmt
in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of and Sixty Six Paisas Only
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc &
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement. (No extra will be paid in
variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:(E) Stair case (i) Ground Fl.Design Mix
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Seven Thousand
etc. propping and centering below supporting floor to ceiling and removal of the same for Four Hundred Ninety
in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of Three and Sixty Paisas
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc & Only
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement. (No extra will be paid in
variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in: (E) Stair case (i) First Fl. Design Mix
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Seven Thousand
etc. propping and centering below supporting floor to ceiling and removal of the same for Five Hundred Thirty
in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of Three and Fifty Five
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc & Paisas Only
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement. (No extra will be paid in
variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in: (E) Stair case (i) SECOND Fl. Design Mix
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Six Thousand
39 549.00 Cmt etc. propping and centering below supporting floor to ceiling and removal of the same for 6709.01 Seven Hundred Nine and Cmt
in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of One Paisas Only
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc &
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement. (No extra will be paid in
variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in: (D) RCC Wall up to Ground floor (Design Mix)
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Six Thousand
etc. propping and centering below supporting floor to ceiling and removal of the same for Seven Hundred Forty
in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of Eight and Ninety Five
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc & Paisas Only
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement. (No extra will be paid in
variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in: (D) RCC Wall up to First Floor Slab lvl. (Design Mix)
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Six Thousand
etc. propping and centering below supporting floor to ceiling and removal of the same for Seven Hundred Eighty
in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of Eight and Ninety Paisas
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc & Only
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement. (No extra will be paid in
variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in: (D) RCC Wall up to Second floor (Design Mix)
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and laying in position M-30 grade concrete for reinforced cement concrete
work, using cement concrete work using cement content as per approved Design Mix
manufactured in fully automatic batching plant and transported to site of work in transit
mixer for any lead having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of batching plant
from transit mixer to site of laying, cost of water tight Centering , shuttering by using
mm thick water proof ply with Exposed work in centring, shuttering & Providing
formwork of steel cup lock system including centring shuttering strutting and propping Rupees Six Thousand
etc. propping and centering below supporting floor to ceiling and removal of the same for Eight Hundred Twenty
in situ reinforced concrete and plain concrete work in flat surfaces such as soffits of Eight and Eighty Four
suspended floors slabs Landings walls, Fins and beams, column and the like, floors etc & Paisas Only
sides and soffits of beams, Haunching cantilevers Girders, using grouting if required,
admixture in recommended proposition as per IS:9103 to accelerated, retard, setting of
concrete, improve workability as per direction of engineer in charge and approved , rates
includes all heights Up to 4.50 mt, excluding reinforcement. (No extra will be paid in
variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in: (D) RCC Wall up to Terrace floor (Design Mix)
Providing laying controlled cement concrete M-250 and curing complete excluding the Rupees Four Thousand
cost of form work and reinforcement for reinforced concrete work in (A) for foundation, Six Hundred Forty One
footing, Bases of columns etc and Mass concrete. and Thirty Three Paisas
Providing & laying controlled cement concrete M-250 with curing etc. complete incl. the Rupees Seven Thousand
cost of form work but excluding the cost of reinforcement for R.C.C. work for column up Six Hundred Ninety
to plinth. Three and Seventy Six
Providing & laying controlled cement concrete M-250 with curing etc. complete incl. the Rupees Five Thousand
45 118.00 Cmt cost of form work but excluding the cost of reinforcement for R.C.C. work for Ground 5776.06 Seven Hundred Seventy Cmt
beam & Plinth beams etc. Six and Six Paisas Only
Providing & laying controlled cement concrete M-200 with curing etc. complete including Rupees Five Thousand
46 35.00 Cmt the cost of form work but excluding the cost of reinforcement for R.C.C. work in 5303.07 Three Hundred Three Cmt
foundation and plinth for Copping. and Seven Paisas Only
Providing & laying controlled cement concrete M-200 with curing etc. complete including
Rupees Seven Thousand
the cost of form work but excluding the cost of reinforcement for R.C.C. work at Ground
47 76.00 Cmt 7801.06 Eight Hundred One and Cmt
Floor for Column.
Six Paisas Only
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing & laying controlled cement concrete M-200 with curing etc. complete including Rupees Six Thousand
the cost of form work but excluding the cost of reinforcement for R.C.C. work at Ground Four Hundred Sixty Six
Floor for Beam, Lintel, Chajja. and Thirty Five Paisas
Providing and Laying controlled Cement Concrete M-200 and curing etc. Complete Rupees Six Thousand
including the cost of form work but excluding the cost of reinforcement for R.C.C. work at Six Hundred Thirty One
Ground Floor for Slabs & Shelves etc. and Forty Five Paisas
Providing and laying controlled cement concrete M.200 and curing complete excluding Rupees Three Thousand
the cost of formwork and reinforcement for reinforced concrete work in (A) Foundations, Nine Hundred Seventy
footings, Base of columns and Mass concrete. at Grade Slab at Plinth level and Eighty Six Paisas
Providing and laying trimix vaccum dewatering process controlled cement concrete M-
Rupees Six Thousand
200 and curing complete excluding the cost of form work including using vaccum
Four Hundred Sixty Four
51 855.00 Cmt dewatering machine mechanical vibrator, mechanical floater & mechanical trowel for 6464.32 Cmt
and Thirty Two Paisas
finishing by mixer machine as directed including cutting groove & filling joint as
specialized etc. comp.
Providing TMT Bar FE 500/500D reinforcement for R.C.C. work including bending, Rupees Seventy Eight
52 1415666.91 Kg. binding and placing in position complete upto any floor any height 78.82 and Eighty Two Paisas Kg.
Brick work using common burnt clay building bricks having crushing strength not less Rupees Four Thousand
than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:6 (1- Cement : 6 -fine One Hundred Twenty
sand)(B) Conventional. One and Fifty Five Paisas
Brick work using common burnt clay building bricks having crushing strength not less
Rupees Four Thousand
than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:6 (1- Cement : 6 -fine
54 346.00 Cmt. 4163.05 One Hundred Sixty Three Cmt.
sand)(B) Conventional. Extra for brick work in superstructure above floor two level Item
and Five Paisas Only
No. 1(6.12) (B) Conventional
Half brick masonry in common brunt clay building bricks having crushing strength not Rupees Six Hundred
55 78.00 Smt. less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in 614.84 Fourteen and Eighty Four Smt.
foundation and plinth (B) Conventional Paisas Only
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and laying autoclave aerated concrete blocks as per drawing (Thickness
mm) in single or multiple layers with approved block laying polymer modified adhesive
mortar. Crushing strength of aerated concrete block shall not be less than 40 KG/sqcm,
minimum density in oven dry condition between 651 to 750 KG/CUM, thermal
conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and Rupees Four Thousand
plumb and cleaning the surface with necessary tool tackles The drying shrinkage shall be Five Hundred Ninety
56 875.00 Cmt not more than 0.05 percent for Grade 1 blocks and 0.10 percent for Grade 2 blocks when 4597.84 Cmt
Seven and Eighty Four
tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, Paisas Only
racking / flush jointing etc complete, as per drawing / specification etc, complete As per
drawings and design supplied by architect and instruction given E.I.C. For all civil,
plumbing, electrical & infrastructure works.
a) Ground FLoor
Providing and laying autoclave aerated concrete blocks as per drawing (Thickness
mm) in single or multiple layers with approved block laying polymer modified adhesive
mortar. Crushing strength of aerated concrete block shall not be less than 40 KG/sqcm,
minimum density in oven dry condition between 651 to 750 KG/CUM, thermal
conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and Rupees Four Thousand
plumb and cleaning the surface with necessary tool tackles The drying shrinkage shall be Six Hundred Thirty Nine
57 768.00 Cmt not more than 0.05 percent for Grade 1 blocks and 0.10 percent for Grade 2 blocks when 4639.34 Cmt
and Thirty Four Paisas
tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, Only
racking / flush jointing etc complete, as per drawing / specification etc, complete As per
drawings and design supplied by architect and instruction given E.I.C. For all civil,
plumbing, electrical & infrastructure works.
Providing and laying autoclave aerated concrete blocks as per drawing (Thickness
mm) in single or multiple layers with approved block laying polymer modified adhesive
mortar. Crushing strength of aerated concrete block shall not be less than 40 KG/sqcm,
minimum density in oven dry condition between 651 to 750 KG/CUM, thermal
conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and
plumb and cleaning the surface with necessary tool tackles The drying shrinkage shall be Rupees Four Thousand
58 716.00 Cmt not more than 0.05 percent for Grade 1 blocks and 0.10 percent for Grade 2 blocks when 4680.85 Six Hundred Eighty and Cmt
tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, Eighty Five Paisas Only
racking / flush jointing etc complete, as per drawing / specification etc, complete As per
drawings and design supplied by architect and instruction given E.I.C. For all civil,
plumbing, electrical & infrastructure works.
c) Second Floor
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and laying autoclave aerated concrete blocks as per drawing (Thickness
mm) in single or multiple layers with approved block laying polymer modified adhesive
mortar. Crushing strength of aerated concrete block shall not be less than 40 KG/sqcm,
minimum density in oven dry condition between 651 to 750 KG/CUM, thermal
conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and Rupees Four Thousand
plumb and cleaning the surface with necessary tool tackles The drying shrinkage shall be Seven Hundred Twenty
59 231.00 Cmt not more than 0.05 percent for Grade 1 blocks and 0.10 percent for Grade 2 blocks when 4722.35 Cmt
Two and Thirty Five
tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, Paisas Only
racking / flush jointing etc complete, as per drawing / specification etc, complete As per
drawings and design supplied by architect and instruction given E.I.C. For all civil,
plumbing, electrical & infrastructure works.
d) Third Floor & terrace
Providing and laying autoclave aerated concrete blocks as per drawing (Thickness
mm ) in single or multiple layers with approved block laying polymer modified adhesive
mortar. Crushing strength of aerated concrete block shall not be less than 40 KG/sqcm,
minimum density in oven dry condition between 651 to 750 KG/CUM, thermal
conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and Rupees Four Thousand
plumb and cleaning the surface with necessary tool tackles The drying shrinkage shall be Five Hundred Ninety
60 89.00 Cmt not more than 0.05 percent for Grade 1 blocks and 0.10 percent for Grade 2 blocks when 4597.84 Cmt
Seven and Eighty Four
tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, Paisas Only
racking / flush jointing etc complete, as per drawing / specification etc, complete As per
drawings and design supplied by architect and instruction given E.I.C. For all civil,
plumbing, electrical & infrastructure works.
a) Ground Floor
Providing and laying autoclave aerated concrete blocks as per drawing (Thickness
mm ) in single or multiple layers with approved block laying polymer modified adhesive
mortar. Crushing strength of aerated concrete block shall not be less than 40 KG/sqcm,
minimum density in oven dry condition between 651 to 750 KG/CUM, thermal
conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and Rupees Four Thousand
plumb and cleaning the surface with necessary tool tackles The drying shrinkage shall be Six Hundred Thirty Nine
61 83.00 Cmt not more than 0.05 percent for Grade 1 blocks and 0.10 percent for Grade 2 blocks when 4639.34 Cmt
and Thirty Four Paisas
tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, Only
racking / flush jointing etc complete, as per drawing / specification etc, complete As per
drawings and design supplied by architect and instruction given E.I.C. For all civil,
plumbing, electrical & infrastructure works.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and laying autoclave aerated concrete blocks as per drawing (Thickness
mm ) in single or multiple layers with approved block laying polymer modified adhesive
mortar. Crushing strength of aerated concrete block shall not be less than 40 KG/sqcm,
minimum density in oven dry condition between 651 to 750 KG/CUM, thermal
conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and
plumb and cleaning the surface with necessary tool tackles The drying shrinkage shall be Rupees Four Thousand
62 115.00 Cmt not more than 0.05 percent for Grade 1 blocks and 0.10 percent for Grade 2 blocks when 4680.85 Six Hundred Eighty and Cmt
tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, Eighty Five Paisas Only
racking / flush jointing etc complete, as per drawing / specification etc, complete As per
drawings and design supplied by architect and instruction given E.I.C. For all civil,
plumbing, electrical & infrastructure works.
c) Second Floor
Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or Rupees One Hundred
63 11944.18 Smt half brick walls for interior plastering upto floor two level and finished even and smooth 171.21 Seventy One and Twenty Smt
in (ii) Cement mortar 1:4 (1- cement :4-sand) (i)Ground Floor One Paisas Only
Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or
Rupees One Hundred
half brick walls for interior plastering above floor two level and finished even and smooth
64 6795.00 Smt 197.79 Ninety Seven and Smt
in (ii) Cement mortar 1:4 (1-cement :4-sand) (ii)First Floor
Seventy Nine Paisas Only
Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or
half brick walls for interior plastering above floor two level and finished even and smooth Rupees Two Hundred
65 6708.00 Smt in (ii) Cement mortar 1:4 (1-cement :4-sand) 224.37 Twenty Four and Thirty Smt
(ii) SECOND Floor Seven Paisas Only
Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or
Rupees Two Hundred
half brick walls for interior plastering above floor two level and finished even and smooth
66 852.00 Smt in (ii) Cement mortar 1:4 (1-cement :4-sand)
250.95 Fifty and Ninety Five Smt
(ii) Terrace Floor
Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior Rupees One Hundred
67 3064.00 Smt plastering upto floor two level and finished even and smooth in (i)Cement mortar 1:3 (1- 169.09 Sixty Nine and Nine Smt
cement:3-sand) (i) Ground Floor Paisas Only
Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior
Rupees One Hundred
plastering above floor two level and finished even and smooth in (i)Cement mortar 1:3 (1-
68 2745.00 Smt 190.47 Ninety and Forty Seven Smt
(i) First Floor.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior
Rupees Two Hundred
plastering above floor two level and finished even and smooth in (i)Cement mortar 1:3 (1-
69 2806.00 Smt 211.84 Eleven and Eighty Four Smt
(i) Second Floor
Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior
Rupees Two Hundred
plastering above floor two level and finished even and smooth in (i)Cement mortar 1:3 (1-
70 322.00 Smt 233.21 Thirty Three and Twenty Smt
One Paisas Only
(i) Terrace Floor
20mm thick sand faced cement plaster on walls upto height 10 metres above ground level Rupees Three Hundred
71 6621.00 Smt consisting of 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick 337.52 Thirty Seven and Fifty Smt
finishing coat of C.M. 1:1 (1-cement : 1-sand) etc. complete. Ground & First Floor Two Paisas Only
20mm thick sand faced cement plaster on walls above height 10 metres above ground
Rupees Three Hundred
level consisting of 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm
72 2787.00 Smt 364.11 Sixty Four and Eleven Smt
thick finishing coat of C.M. 1:1 (1-cement : 1-sand) etc. complete. - Second & Tarrace Floor
Providing throating or plaster drip and moulding to R.C.C. chhajja Rupees Forty Two and
Two Paisas Only
Providing & Fixing the Chicken wire mesh Jali 16 x24 or approved size 22 gauge applying
Rupees Three Hundred
between the RCC and masonry junction in proper line, level and plumb with all material,
74 2524.00 Smt 359.52 Fifty Nine and Fifty Two Smt
labour, tools, tackles and equipment including fixing the jali with nails, etc complete as
directed by the Engineer-in-charge.
Wall painting (two coats) with plastic emulsion paint of approved brand and manufacture
on undecorated wall surface to give an even shade including throughly brushing the Rupees Eighty and
surface free from mortar droppings and other foreign matter and sand papered smooth. Eighty Seven Paisas Only
Applying two coats of putty & two coats of primer of approved brand and manufacture on
Rupees Forty and Fifty
76 23675.00 Smt new wall surface to give an even shade including thoroughly brushing the surface free 40.59 Smt
Nine Paisas Only
from mortar dropping and other foreign matter and sand papered smooth.
Finishing wall with weather proof (Apex) exterior emulsion paint two coats on wall
Rupees One Hundred
surface & two coats of primer of approved brand to give an required shape even shade
77 9408.00 Smt 136.75 Thirty Six and Seventy Smt
after thoroughly brushing the surface to remove all dirt, and remains of loose powdered
Five Paisas Only
materials.etc complete
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing 20 mm thick water proof cement plaster using water proofing powder
1Kg/1bag of cement for all floors on brick / concrete wall work using water proofing
Rupees Two Hundred
materials in C M 1: 4 ( 1 cement 4 coasrse sand) including finishing with a flooting coat of
Seventy Nine and
78 407.00 Smt neat cement slurry etc complete for all floor. and shall be guaranteed for minimum period 279.77 Smt
Seventy Seven Paisas
of 10 years after handing over the completed building by the main contractor to be
finished as directed. Stamp paper guarantee 10 years to be furnished before receiving any
payment from the client.
Providing and laying polished Granite stone slab 25mm thick in flooring,risers of steps,
Rupees Two Thousand
skirting Dedo and pillars laid on 20mm thick cement mortar 1:3 (1-Cement : 3 coarse
79 1353.00 Smt 2144.02 One Hundred Forty Four Smt
sand) and jointed with gray cement slury including rubbing and polishing etc. complete.
and Two Paisas Only
as per instructions of EIC.
Providing and laying 24" x 24" vitrified glossy/ satin/ matte finish 8 mm thick tile flooring
over 20 mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new Rupees One Thousand
80 5239.00 Smt surface or fixing on existing flooring by adhesive material including dismentaling of 1451.16 Four Hundred Fifty One Smt
existing flooring and jointed with color cement slurry including finised with flush pointing and Sixteen Paisas Only
& cleaning the surface etc. complete for light shade
Providing and laying Ceramic tiles 6mm thick in flooring treads of steps and landing laid Rupees Nine Hundred
81 446.00 Smt on a bed of 12mm thick cement mortar 1:3 (1- cement : 3-coarse sand ) finishing with 981.57 Eighty One and Fifty Smt
flush pointing in white cement. Seven Paisas Only
Providing and laying coloured glazed tiles of the size 300 mm x 450 mm x 8 mm in Rupees One Thousand
skirting, risers of steps and dedo on 10 mm. thick cement plaster 1:3 (1 cement : 3 coarse Four Hundred Fifty Two
sand) & jointed with white cement slurry. and Seventy Nine Paisas
Providing and laying Tactile flooring tiles 300mm x 300mm in flooring 12 mm. Thick Rupees One Thousand
83 444.00 Smt cement mortar 1:3 (1 cement : 3 coarse sand) pointing in white ceand jointed with white 1064.54 Sixty Four and Fifty Four Smt
cement slurry. Paisas Only
Providing and laying polished Granite slab flooring over 20 mm (average) base of cement Rupees Two Thousand
84 416.00 Smt mortar 1:6 (1 cement : 6 coarse sand) laid and jointed with grey cement slurry including 2161.40 One Hundred Sixty One Smt
rubbing and polishing complete.18 mm thick and Forty Paisas Only
Providing and laying polished granite stone slab 18 mm thick in risers of steps (Revert
Rupees Two Thousand
polished), dedo and pllars laid on 10 mm thick cement mortar 1:3 (1 cement : 3 coarse
85 1202.00 Smt 2310.17 Three Hundred Ten and Smt
sand) and jointed with gray cement slurry including half round moulding, rubbing &
Seventeen Paisas Only
polishing etc. complete.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and fixing fully openable Partly Glazed Partly Panelled standard extruded
alluminium door of double shutter with colour anodized hollow section frame of
approved shade & pivoted double shutter fabricated from aluminum standard section for
outer frame size 101.60mm x 44.75mm x 1.75mm of Domal (of jindal section no:2425 @
Wt 1.301 Kg /Rmt) and door style size 85.00mm x 4.45mm x1.56mm (of jindal section Rupees Four Thousand
86 281.00 Smt no:4590 @ Wt 1.139 Kg /Rmt) and top & bottom rail of aluminium section size 95.25mm 4859.11 Eight Hundred Fifty Nine Smt
x 44.45mm x 1.70mm (of jindal section no:4553 @ Wt 1.301 Kg /Rmt) and lock rail size and Eleven Paisas Only
150mm x 44.45mm x 2.65mm (of jindal section no:4600 @ Wt 2.786 Kg /Rmt) including
providing rubber gasket and glazing clips ( @ Wt 0.124 Kg/Rmt) around the Acrylic Sheet
Scretches proof fixed with transparent silicon gasket including all required materials
labour and equipments as per detailed drwg. As directed.
Providing and fixing window having extruded aluminum Colour anodized 27 x 65 section
of Domal (of Hindustan Section no: @ wt.of 0.738 Kg/mt), horizontal Three track member
size 75mm x 45mm x 1.15mm (of @ Wt.1.30 Kg/mt), vertical member of size 75mm
x 45mm x 1.15mm (of @ Wt. 1.30. Kg/mt) with sliding shutters of horizontal
Rupees Six Thousand
member size 66 mmx22mm x1.1mm (of @ wt.of 0.660 Kg/mt), with 5 mm th
87 206.00 Smt 6969.00 Nine Hundred Sixty Nine Smt
transparent bronze colour tinted float glass with powder coated aluminum fittings &
fixtures and transparent silicon sEachlant glass fixing to frame as per details and
including MOSQUITO Shutter conststing of s.s. wire gage of avaerage width aperature
1.4 mm with wire of dia meter 0 .63mm necessary cutting and making good etc. for
Providing and fixing glazed louvered glass windows and ventilators with teak wood frame Rupees Four Thousand
10cm. x 7cm. size including 3 coats of oil painting to wood work etc.complete. with Four Hundred Thirty
wooden louvers plank 12mm thick Four and Thirty Five
Providing and fixing M.S. grill of required pattern of windows etc. with M.S.. flats at
Rupees One Hundred
required spacing and frame alround square or round headed bolts and nuts or by
89 12340.00 Kg. 105.18 Five and Eighteen Paisas Kg.
screws.including applying a priming coat of red lead paint and two coats of oil painting etc
complete (A)Plain grill
Steel work, welded in built up sections framed work including cutting, hoisting, fixing in
Rupees Nine Thousand
position and applying a priming coat of read lead paint. (A)In beams and joists, channels
90 349.59 qntle 9108.48 One Hundred Eight and qntle
angles Tees, flats, with connecting plates or angle cleats as in main and cross beams. Hip
Forty Eight Paisas Only
and jack rafters, purlins conneted to common rafters and the like .
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Design and Supply and installation of glass façade with fixed glazing made of 12mm thick
clear toughen glass with OZONE SPIDER with OSP‐A22 ‐1 WAY SPIDER FOR CEILING
FIXING;316 GRADE; FINISH‐SSS; 94mm ; OSP‐A44 ‐2 WAY SPIDER FOR WALL FIXING;
316 GRADE; FINISH‐SSS; 200mmx 94mm ;OSP‐A4 ‐ 4 WAY SPIDER WITH FIN;
GRADE; FINISH‐SSS; 94+94mm x 200mm;OSP‐AFB‐36‐FL ‐ARTICULATED FLAT HEAD
BOLT FOR 15MM THK OF GLASS; 316 GRADE; FINISH‐SSS; GLASS HOLE DIA.
MM;OSP‐FP‐350 ‐FIN PLATE 350MM X 93MM; GLASS HOLE DIA.‐22MM, SSS FINISH; Rupees Three Thousand
OSP‐FP‐400 ‐FIN PLATE 400MM X 93MM; GLASS HOLE DIA.‐22MM, SSS FINISH; Eight Hundred Seventy
OSP‐FP‐450 ‐FIN PLATE 450MM X 93MM; GLASS HOLE DIA.‐22MM, SSS FINISH; Eight and Forty Paisas
OSP‐SP‐VS‐400 ‐VERTICAL SPLICE PLATE 400MM; GLASS HOLE DIA. 22MM; SSS FINISH. Only
The contact between glass surface and metal shall be protected by EPDM washers. The
glass hole shall be protected from direct contact with metal by Derlin bush. A spring
washer confirming to SS316 act as a locking mechanism to secude nut in place ensuring
full tightness for long period of time. Contractor must submitted wind load, Structural
stability and warranty certificate.
Providing and fixing flush door both sides laminated shutter fabricated from 35 mm thick
solid core malemine faced three layered pre laminated flat pressed wood based exterior
grade bonded BWP/BWR synthetic resin having stamped IS 12823 grade I type II Rupees Three Thousand
92 259.00 Smt including three coats of lacquer polishing to exposed wooden surfaces and including 3617.14 Six Hundred Seventeen Smt
providing and fixing of Floor door stopper & fixing of S.S finish decorative type heavy and Fourteen Paisas Only
guage designs fixtures / fastening etc. complete As per drawings and design supplied by
architect and instruction given by authority and E.I.C.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid
plain flush door shutter of required size comprising of virgin polymer of K value 58-60
(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice
husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)
having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) Rupees Three Thousand
93 218.00 Smt & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 3914.07 Nine Hundred Fourteen Smt
N/mm2 and resistance to spread of flame of Class A category with property of being and Seven Paisas Only
termite/borer proof, water/moisture proof and fire retardant and fixing with stainless
steel butt hinges of required size with necessary full body threaded star headed counter
sunk S.S screws, all as per direction of Engineer-In Charge. 35 MM
Providing and fixing bright finish brass hydraulic door closer of approved model and Rupees One Thousand
make with necessary screws and finishing etc. complete. Four Hundred Twenty
Two and Eighty Four
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and fixing 3 mm thick PVC sheets as signange and display of health
signs/information of required size having retro reflective letters/design as per Rupees Three Hundred
95 100.00 Each requiement, fixing the same through approved adhesive etc. complete work shall e carried 382.79 Eighty Two and Seventy Each
out as per instruction of Engineer-in-charge (Approved make PVC foamed sheet only) (45 Nine Paisas Only
Providing and Fixing Best Quality of S.S. Metal Letter on Outerside Wall at Any Height Rupees Nine Hundred
96 100.00 Each Including Polishing & Anchoring Labour Etc Complete as Directed by Engineer in charge. 929.20 Twenty Nine and Twenty Each
Providing and laying chaina mosic water proofing treatment on terrace including applying
neat cement slurry 2.75 Kg./Sqm. Of cement admixed with water proofing compound
after cleaning the surface (b) laying cement concrete usig brick bats 25 to 100 mm size
with 50% C.M. 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound Rupees Nine Hundred
97 2907.00 Smt over 20 mm thick layer of C.M. 1:5 to required slope including rounding of junction of 937.28 Thirty Seven and Twenty Smt
walls and slabs (a) after two days of proper curing applying a second with 20 mm thick Eight Paisas Only
C.M. 1:4 and china mosaic tiling and finally finishing the surface with trowel white cement
slurry (e) after finishing the whole terrace shall be flooded with water for a period of two
Providing and fixing stainless steel railing 50mm dia.(16 gauge-Grade 304) TOP RAIL
with 1 mtr c/c VERTICAL SUPPORT 37.5mm dia.(16 gauge-Grade 304), 3 NO. 25mm
dia.(16 gauge-Grade 304) HORI. MEMBER ., including welding, grinding, buffing, polishing
Rupees Three Thousand
and making curvature (wherever required) ,for staircase on the side of waist slab with
Eight Hundred Forty
98 681.16 Rmt suitable arrangement as per drwaing, (for payment purpose only hand rail Running meter 3847.54 Rmt
Seven and Fifty Four
will be consider, and other stainless steel members shall are inclusive of fixing accessories
such as Baluster, supports, horizontal members, nuts, bolts, fasteners etc.)Rate includes
for all lead & lift. etc, complete as per drawings and design supplied by architect and
instruction given by authority and E.I.C.
Providing, fixing and construction of sandwich type platform of 18 mm thick Granite
polished stone top, 80 mm wide edge full moulded Facia Patti with 25mm thick one side
polished Kota stone for bottom & vertical supports sandwich type at 1.00 m interval Rupees Eight Thousand
including necessary cement mortar 1:2 Kota shall be fixed in cement joints and pointing Six Hundred Ninety
as specified in Kitchen / Pantry / Counter / Laboratory etc with necessary adhesive, Three and Twelve Paisas
making of edges, polishing curing daily mopping with water and kerosene etc comp as Only
directed of Engineer-in-charge. (Measured only vision finished top plan area)
Providing and fixing Flexible Homogeneous Vinyl Flooring of With treatment of Rupees One Thousand
Plyurethane Reinforced Surface, Densely Compacted, Anti-Bactaril and fungicidal and Eight Hundred Ninety
Antistatic havng thickness of 2.00mm With weight of 3150 g/m2 with levelling, chemical Three and Seventy Five
adhasive for fixing, corner junction. Paisas Only
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Wall Painting (two coats) with antibacterial polyrethane epoxy paint approved brand and
Rupees Four Hundred
manufacture on internal walls to give an even and smooth surface. Thoroughly brushing
101 1184.00 Smt. 454.50 Fifty Four and Fifty Smt.
the surface free from mortar dropings and other forein matter and sand prepared smooth.
Providing & applying two Componant ,non slumping ,non-sagging, thixotropic epoxy
bedding compond & adhesive compatible with for tiles for coving at radius of 25 mm or
Rupees Five Hundred
as directed by the architect's / Engineer-in-charge make it fit for tiles inclusive of Labour,
102 800.00 RMT 575.70 Seventy Five and Seventy RMT
material and Equipment etc. for all heights, location, shape & size as directed by the
architect/Bank engineer incharge. (Actual Length shall be measured for payment.)
Providing corrugated G.I. sheet of class-3 roofing fixed with glavanished iron J or L Hooks,
Rupees Seven Hundred
Bolts and nuts 8mm diameter with bitumen and G.I. limpet washer or G.I. limpet washer.
103 910.00 Smt 734.19 Thirty Four and Nineteen Smt
filled with white lead complete excluding the cost of purlins, Rafters and Trusses.(1)
mm thick sheet.
Corner Guard Protection System in entire hospital : Supply and Installation of Corner
Rupees Seven Hundred
Guard protection system fixed to brick wall/or tile/dado at the corner from finished floor
104 320.00 RMT level. It should be adjustable end cap. Providing and fixing brush/mirror finish S.S 304 788.81 Eighty Eight and Eighty RMT
One Paisas Only
grade Angle 40.0 x 40.0 x 3.0 mm &. 1.00mt. Ht. x 3.75 kg/mt. = 3.75 kg.
Providing and applying 2mm thick Texture Plaster Terre Palette (Earthen Textures,
Spectrum, Coral or equivalent) incorporating fine filaments made of polymer and Rupees Three Hundred
105 5798.00 Smt aggregating natural stone powder with making grooves on existing base coat of 18 mm 351.48 Fifty One and Forty Eight Smt
thick smooth mala plaster etc. Complete Colour and shade as approved by Architect/ Paisas Only
Engineer in charge for all floor all height.
Painting Two coats over & including a priming coat on new steel and other metal surfaces Rupees One Hundred
106 403.00 Smt with enamel paint, brushing interior to give an even shade including cleaning the surface 102.66 Two and Sixty Six Paisas Smt
of all dirt, dust and other foreign matter.. Only
Painting two coats (excluding priming coat) on new steel and other metal surface with
107 1118.00 Smt. enamel paint, brushing, interior to give an even shade including cleaning the surface an 90.00 Rupees Ninety Only Smt.
even shade including cleanicn the surface of all dirt, dust and other foreign matter.
Providing & Plantation of semi carpet Lawn (Selection 1) the scope includes prepaid
ground for planting of lawn, soil spreading, mixing of soil & manures, rolling the same etc
comp. Labour cost for Lawn Plantation semi carpet Lawn Cost including carting, loading & Rupees Two Hundred
108 250.00 Smt. unloading at site etc and includes required dose of pesticides & Ant termite treatment 248.46 Forty Eight and Forty Six Smt.
Labour charges for maintenance of semi carpet Lawn including tools & tackles. including Paisas Only
Providing, mixing & spreading fertilizer Manure ,1 year maintenance etc complete as
directed by architect /E.I.C
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing & Plantation of Shrubs (mini 3 feet height) by digging of pit size 1x1x1 feet,
Rupees One Hundred
adding soil, farm yard manure, DAP, Pesticide, Plantation of sapling. Making proper tree
109 50.00 NOS. 151.50 Fifty One and Fifty Paisas NOS.
basin & putting proper support including Providing, mixing & spreading fertilizer Manure
,1 year maintenance etc complete as directed by architect /E.I.C
Providing & Plantation of Green belt trees by digging of pit size 2x2x2 feet, height 10 feet
adding soil, farm yard manure , DAP, pesticide, plantation of sapling. Making proper tree
Rupees Fifty and Fifty
110 50.00 NOS. basin & putting proper support including back filling the trench, watering etc including 50.50 NOS.
Providing, mixing & spreading fertilizer Manure ,1 year maintenance etc complete as
directed by architect /E.I.C
Bowing and developing flowering plants grown in nusery having approximate height 4 to
5 ft or Height ad per Landscaps Plan with natural growith of soil packed in polithyline bag Rupees One Hundred
111 50.00 NOS. or Earthern pot. Including organic & chemical fertilizer Pesticides, fungicides, hormones & 171.70 Seventy One and Seventy NOS.
maintaining the plants up to three months as deserted. Bottol palm. Paisas Only
Providing and fixing eco-friendly light weight calcium silicate false ceiling tiles having
Tegular edge & 15 mm Thick Densified edges on the Tile Periphery for Extra Strength The
Light weight calcium silicate ceiling tiles shall have , light reflection 85% non-combustible
as per B.S. 476 part IV, 100% humidity resistance and also having thermal
conductivity0.043° w/m KC.for the best thermal Insulation. The Light weight calcium
Silicate tile shall be of approved texture Fine fissured/ Spintone/Cosmos having NRC
value of 0.5 & Globe having NRC value of 0.75 NRC or equivalent of size 595 X 595 mm to
be laid on true horizontal level suspended inter locking metal grid of hot dipped
galvanized steel sections (galvanizing @120 grams per sqm including both side) Rupees One Thousand
consisting of main ‘T’ runner suitably spaced at joints to get required length and size of Six Hundred Seventy
24X38mm made from 0.30 mm thick (minimum) sheet, 1200mm centre to centre, and Four and Eight Paisas
cross ‘T’ of size 24X28mm made out of 0.33mm (Minimum) sheet spaced 1200mm along Only
spaced between main ‘T’ at 600mm centre to centre to form agrid of 1200X600mm and
secondary cross ’T’ of length 600mm and size 24x28mm made of 0.30 mm thick
(Minimum) sheet to be interlocked at middle of the 1200X600mm panel to form grid of
size 600X600mm resting on periphery walls/partitions on a perimeter wall angle pre-
coated steel of size (24X24X3000mm made of 0.40mm thick (minimum) sheet with the
help of rawl plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm
interval and laying 15mm thick Densified edges
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Main Door Signage
3Stainless Steel plate of grade 304 having size 500x150x1mm thick (brush finish) shall be Rupees Fourteen
used as base / background. The height of the font shall be 30mm for name pasting and the Thousand Nine Hundred
designation shall have 15mm height pasted below the name of person. Forty Two and Ninety
vinyl fonts Five Paisas Only
Providing and fixng curtain For Door/Window using Fire retardent Material including
necessary hanging attachments like hooks/ rings, 25mm SS rod/ alluminium channel/ Rupees One Thousand
114 480.00 Smt Socket on rod ends/ middle supporting sockets including 1 inch Adjustable Curtain S.S. 1717.00 Seven Hundred Smt
Rod up to 12 ft long with best quality Curtain Knobs and bracket or socket (2 nos 1 set) Seventeen Only
Supply & Installation of Cubicle/ Privacy Curtains for Hospital Track Material Made of
Aluminium alloy (6063-T6), with corrosion resistanceproperties and Standard white
powder coatingTrack Size (Approximate)Gauge 1.7mm Height 25mm Width 20mm
Runner type Wheel or Glider Type Runner material Made of Nylon of PVC Hooks Stainless
Steel 202 or more Bends Tracks are bendable to a radium of 300 mm at 90 degree to
cover the whole bed Track height As per site requirement Track roof suspenders Made of
aluminium pipe of at least 12 mm diameter and the Upper Circular Plate made of
aluminium with at least 50 mm diameter.These should be white powder Coated and fixed
with the ceiling is with anchors, bolts, screws etc.Track wall supports Aluminium white
Powder coated Tack bridge clamp Aluminium white Powder coated Curtain Removal Rupees One Thousand
115 397.00 RMT Point Optional : Curtain runner removal point for loading and unloading of runners 1696.80 Six Hundred Ninety Six RMT
Curtain Material Polyester Blended Standard Curtain Size Height At least 84 inch or more and Eighty Paisas Only
Width At least 46 inch or more Mesh(Net) Size At least 18 inch or more from top of the
curtain and made of nylon Curtains Type:Stain Retardant Cubicle Curtains These Curtains
should be made up of fabrics with inherent antibacterial and flame retardant
properties.These curtains should be wrinkle free and shrink proof with Anti odour and
Anti-fungal properties.It should meet the international Antimicrobial Test JISL
1902/ISO20743These Curtains should have Dire retardent,stain retardant qualities with
water repellent quality with rust proof SS grommets 6" on centers. Designs and Colours
should be approved by the user department.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing & fixing of reinforcement bars ( reiforcement bars shall be paid extra under
relevant item of work ) after drilling the hole of required diameter & depth ,cleanning of
the same ,providing /filling the hole with Injection Mortar (HIT HY 150 of Hilti or
approved equivalant ),inserting reinforcement bar etc. complete as per Manufacturers & Rupees Three Hundred
116 60.00 Each architects instruction.The work shall be carried out by the technical workmens/agency 317.14 Seventeen and Fourteen Each
approved by the manufacturer and under technical supervision of Manufacturer of Paisas Only
Injection grout including all materials,tool tackles ,labour etc.complete.
Providing & fixing of reinforcement bars ( reiforcement bars shall be paid extra under
relevant item of work ) after drilling the hole of required diameter & depth ,cleanning of
the same ,providing /filling the hole with Injection Mortar (HIT HY 150 of Hilti or
Rupees Three Hundred
approved equivalant ),inserting reinforcement bar etc. complete as per Manufacturers &
117 50.00 Each 378.75 Seventy Eight and Each
architects instruction.The work shall be carried out by the technical workmens/agency
Seventy Five Paisas Only
approved by the manufacturer and under technical supervision of Manufacturer of
Injection grout including all materials,tool tackles ,labour etc.complete.(B) 10mm Dia
Providing & fixing of reinforcement bars ( reiforcement bars shall be paid extra under
relevant item of work ) after drilling the hole of required diameter & depth ,cleanning of
the same ,providing /filling the hole with Injection Mortar (HIT HY 150 of Hilti or
Rupees Four Hundred
approved equivalant ),inserting reinforcement bar etc. complete as per Manufacturers &
118 40.00 Each 434.30 Thirty Four and Thirty Each
architects instruction.The work shall be carried out by the technical workmens/agency
approved by the manufacturer and under technical supervision of Manufacturer of
Injection grout including all materials,tool tackles ,labour etc.complete.(C) 12mm Dia
Providing & fixing of reinforcement bars ( reiforcement bars shall be paid extra under
relevant item of work ) after drilling the hole of required diameter & depth ,cleanning of
the same ,providing /filling the hole with Injection Mortar (HIT HY 150 of Hilti or
Rupees Five Hundred
approved equivalant ),inserting reinforcement bar etc. complete as per Manufacturers &
119 30.00 Each 554.49 Fifty Four and Forty Nine Each
architects instruction.The work shall be carried out by the technical workmens/agency
approved by the manufacturer and under technical supervision of Manufacturer of
Injection grout including all materials,tool tackles ,labour etc.complete.(D) 16mm Dia
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing & fixing of reinforcement bars ( reiforcement bars shall be paid extra under
relevant item of work ) after drilling the hole of required diameter & depth ,cleanning of
the same ,providing /filling the hole with Injection Mortar (HIT HY 150 of Hilti or
Rupees Seven Hundred
approved equivalant ),inserting reinforcement bar etc. complete as per Manufacturers &
120 20.00 Each 792.85 Ninety Two and Eighty Each
architects instruction.The work shall be carried out by the technical workmens/agency
Five Paisas Only
approved by the manufacturer and under technical supervision of Manufacturer of
Injection grout including all materials,tool tackles ,labour etc.complete.(E ) 20mm Dia
Providing and laying and fixing 50 mm thick expansion joint by hydro cell semi rigid UV Rupees One Thousand
resistance with high performance laminated closed cell polythene foam joint filler in sheet Four Hundred Ninety
foam as directed, etc. complete. One and Three Paisas
Providing and fixing 25 cm Wide & 3mm thick exterior composite panel on existing Rupees One Thousand
122 500.00 Smt expansion joint horizontally & vertically with all material, hardware, acessories & fittings 1054.34 Fifty Four and Thirty Smt
etc completed. Four Paisas Only
Providing and fixing 60 mm diameter backup rod having minimum density 22 kg per cum
Rupees Sixty Nine and
123 800.00 RMT (ASTMD - 3575) & compression strength of 0.40 kg per sqm (ASTM - 5249) and finishing 69.07 RMT
Seven Paisas Only
with polysulphide sealant etc. complete. For 50 mm wide expansion joint
Making up the even groove, cleaning by air/water blasting and resealing with DOW
Rupees Three Thousand
CORNING make CCS Silicon type of liquid seals for widths 40mm x 10mm after using
124 250.00 RMT 3641.05 Six Hundred Forty One RMT
appropriate back up material of SUPREME make
and Five Paisas Only
Drilling of pilot 250/325 mm dia bore hole in all strata including dual over burdan strata
Rupees Two Thousand
by combination DR / DTH Rig. including lowering of 200/250 mm dia MS ERW pipes in
125 120.00 RMT 2684.30 Six Hundred Eighty Four RMT
bore hole with 4 to 6 mm Gravel ,Lowering of the submersible motor of 2HP along with
and Thirty Paisas Only
flat PVC cable as suggested by Hydrologist.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Cat Eye / Road Stud / RPM: Supplying of Molded Twin Shanks Raised Pavement Markers
made of polycarbonate and ABS moulded body and reflective panels with micro prismatic
lens capable of providing total internal reflection of the light entering the lens face and
shall support a load of 13635 kgs. tested in accordance to ASTM D 4280 Type H and
complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97
DO III Dt 11.06. 1997. The height, width and length shall not exceed 20 mm, 130 mm and Rupees Three Hundred
126 280.00 No 130 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the 326.23 Twenty Six and Twenty No
base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical Three Paisas Only
shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from
the body is to be a minimum value of 500 Kgf. Fixing will be by drilling holes on the road
for the shanks to go inside, without nails and using epoxy resin based adhesive as per
manufacturers recommendation and The color of the marker should be as per the IRC 35-
2015 and as directed by Engineer-in-charge.
Road marking with hot applied thermoplastic paints with reflectorising glass beads on
bitumin surface providing and laying a hot applied thermoplastic compound 2.5 mm thick
including reflectorising glass beads @ 250gms per sqm area, thickness of 2.5mm is
excluding of surface applied glass beds as per IRC:35-2015. The finished surface to be
level, uniform and free from streaks and holes. zebra patta /bump patta lane/center line/ Rupees Three Hundred
127 170.00 Smt edge line/cut patta. The white color marking should provide liminance coefficinet on 367.72 Sixty Seven and Seventy Smt
cemend road shalll be min 130 mcd/m2/lux and Asphalt road shall be min 100 Two Paisas Only
mcd/m2/lux during the service life during the day time. The marking should meet the
performance criteria for night time reflectivity, wet reflectivity and skid resistance as
mentioned in the section-15 of IRC 35-2015. Warranty for the Retro reflectivity should be
FLUSH PARTITION (laminate finish) :
Providing & fixing flush partition up to false ceiling ht (thickness of partition is 75 mm)
having 12 mm thick Marin plywood IS 710 both side on aluminum framing. Aluminum
framing size for vertical & horizontal support is 50 mm x 25 mm. All exposed surfaces
finished with 1 mm thick laminate of approved shade without any air gap and grooving as
per design. Necessary framing to be erected above false ceiling. No extra cost to be paid Rupees Four Thousand
128 430.00 Smt for the same. Before installation, make hole/face plate for conduit pipes of electrical / 4512.31 Five Hundred Twelve and Smt
networking cables with open able stud from partition Including all materials and labor Thirty One Paisas Only
etc. Make necessary grooves as per shown in drawing. All bottom ends are covered with
Ghana teak bidding Patti finished with laminate Complete with all necessary hardware &
adhesives as per details given in drawing and as per instructions of
Architect/consultant/Engineer In charge. Contractor has to provide all necessary cut outs
(race ways.) for Electrical works & no extra payment shall be made for it.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Applying and providing Expansion joint sealing System on 100 mm vide joint including
cleaning of exansion joint by mechanical means provision of adhesive and flexible
Rupees Four Thousand
membrane with required bond length as per menufracturer specification and 4mm thick
129 248.00 Smt 4772.00 Seven Hundred Seventy Smt
alluminium strip covering with one side sloted and bolted with suitable system, inclusive
of all manpower, machinery and material as per specification and as directed.
Providing and fixing 35 mm thick shutters for Doors, windows and clear story windows Rupees Three Thousand
including anodised alluminium butt hinges with necessary screws. (A) Indian Teak Six Hundred Eighty Two
Wood(iii) Partly panelled and partly glazed. and Fifty Four Paisas
Providing and laying polished Kota stone slab flooring over 20mm (Average) thick base of
Rupees One Thousand
cement mortar 1:6 (1-cement : 6-coarse sand) or L.M. 1.1.5 laid over and jointed with grey
131 1955.00 Smt 1001.14 One and Fourteen Paisas Smt
cement slurry including rubbing and polishing etc. complete. (B) 25mm thick
Bed Head panel : Horizontal Bed Head Panel made by high strength aluminium
section,thickness of aluminium section 3 mm. Bed Head Panels offered by us are available Rupees Four Thousand
in Aluminum Powder coated with provision for Gas Outlets & Electrical 5/15 Amps switch Eight Hundred Eighty
sockets. As per the demand of the clients, our bed head panel is offered with Nurse Call Five and Ninety Eight
cutout. complete as per direction of Engineer-in-charge. Paisas Only
Providing and Fixing 6 mm thick Lexan Polycarbonate multi wall roofing sheet fixed with Rupees One Thousand
133 540.00 Smt hilti screw and rubber silicon sealer and alluminium strip of size 50 x 3 mm etc complete 1441.90 Four Hundred Forty One Smt
as directed by Engineer in charge. and Ninety Paisas Only
Providing and applying a seamless lightweight multi- layered system comprising of
primer and finish coat 75 mm thick epoxy coving on the wall to floor joint epoxy 75mm
thick Epoxy Coving System which consist of surface preparation, primer coat. Make coving Rupees Seven Hundred
134 250.00 RMT (VATA) coving with Florscreed C , make finish putty with Florscreed C and silica micro. 786.57 Eighty Six and Fifty Seven RMT
Then Apply two coat Florthane-PU paint of standard make with approved colour and floor Paisas Only
pattern design by architect applied as a top coat. After 48hour of drying etc. Comp. as per
the instructions of I/C.
Writing letter or figures on any surface with black japan paint (stops,comas, hyphens and
Per the like not to be measured and paid for separately)(i) Block (Letters/Figures) (Per 10 Per
Letter Letter pet CM.HT) Rupees Three and Letter
Per Twenty Six Paisas Only Per
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Writing letter or figures on any surface with black japan paint (stops,comas, hyphens and
Per the like not to be measured and paid for separately) (ii) Indian (Letters/Figures) Per
Letter Rupees Three and Forty Letter
Per Three Paisas Only Per
Extra over above items for using thick white paint instead of black japan paint. (i) Block
Per (Letters/Figures) Per
Letter No Rupees and Seven Letter
Per Paisas Only Per
Supplying and fitting of X-ray protective lead sheet (2 mm or as per site requirement) on
Rupees Six Hundred
existing wooden/matel/flush door or on new door but including 6 mm ply wood &
138 25.00 Kg. 696.90 Ninety Six and Ninety Kg.
Hardware accessories (SS D handle 152, SS Aldrop 254 mm long, Goderej door closer, SS
Tower Bolt etc complete.
Supplying and fitting of lead glass of approved quality for X-ray protection of 10 mm thick. Rupees Eight Thousand
139 50.00 sq.ft 8181.00 One Hundred Eighty One sq.ft
Providing & Fixing garware make non transparent NR CHARCOAL , 20 suncontrol film
Rupees Four Hundred
1mm thick with 42% of solar energy reflectance. To be fixed on window glass panels as
140 450.00 Smt 469.65 Sixty Nine and Sixty Five Smt
per instruction in proper maner without any crach,currling and whole etc. up to the
corner and edges of glass panel.
Supplying and fitting of waterproof ISI branded of approved quality Ply wood for all type Rupees One Thousand
of work like furniture and table top or door surfacing etc complete 12mm Two Hundred Thirty
Seven and Twenty Five
Providing and Fixing Special quality Sheet glass one side vision (reflected ) as per desided
Rupees Eight Hundred
by engineer incharge of approved quality bedded in puty and fixed with wooden beadings
142 288.00 Smt including the cost of wooden beadings of first class teak wood and necessary cutting of 858.50 Fifty Eight and Fifty Smt
Glass (4) 4 mm thick
Applying Melamine polishing of Asian paint or Royal paint in any shade as per instruction
of engineer incharge. the work shall be carried out by specilized agency only as per
Rupees Four Hundred
approved manufacture's specification in two or three coat up to satisfaction of engineer
143 240.00 Smt 454.50 Fifty Four and Fifty Smt
incharge on previously Polished wood or wood Base Surface to give an even surface
including cleaning the surface by sandpaper Smooth and also including coat of wood Filler
as directed by Engineer-in-charge.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
providing and fixing single layer 12.5 mm GYPROC make all four side tepered perforated
gypsum acoustical board having eight quadrents having 12 mm hexagonal shaped
perforations and backed acoustical fleece peneling supported on Gypsteel ULTRA 48 x
x 36 x 0.5 mm C stud placed on every 610 mm canter to canter in Gypsteel ULTRA 50 x
x 32 x 0.5 mm width floor channel, for horizontal support between the C-stud place Rupees One Thousand
144 270.00 Smt Noggin Channel on board joint, then board screw fixed to stud at designed spacing all 1818.00 Eight Hundred Eighteen Smt
square and tapered edges of the boards are to be jointed and finished so as to have a flush Only
look which includes filling and finishing with gyproc jointing compound, gyproc joint
paper tape and laying of 50 mm glass wool or synthetic wool with paint and also include
100 mm aluminium skirting as directed by Engineer-in-charge.
Providing and fixing insulated fire rated GI Sheet doors conforming to FD 120-I
classification of IS 3614 :2021 with fire rating of 120 minutes integrity and 30 minutes
insulation. The factory manufactured door frame and shutter assembly shall be made out
of minimum 1.20 mm thick GI Sheet with minimum 120 GSM coating as per IS: 277. Door
and frame should be finished with powder coating in standard RAL shade finish having
DFT of minimum 30 microns. The door should carry a minimum 500 Hrs of salt spray test.
All accressesories like hardware, vision panel, fire & smoke seal etc to be supplied by Fire
door manufacturer only as per the guidelines laid down in IS 3614:2021.Every door must
carry a label confirming to type of door & its fire rating.The door must carry a 5years valid Rupees Five Thousand
145 198.00 Smt test evidence from CBRI-Roorkee / NTH-Kolkata/ NABL accrediated lab which operates in 5302.50 Three Hundred Two and Smt
accordance with ISO/IEC 17025.The Door frame shall be single rebate grooved profile of Fifty Paisas Only
size minimum 100mm x 57mm made out of 1.20mm (18gauge) minimum thick galvanized
steel sheet. Frames shall be butt / mitered joint and field assembeled with bolting system.
Frames to have inbuilt grooved to accomodate Intumuscent fire seal strip 10X4MM, It
shall be fixed in grooves, specifically cut in rebate on all the 3 sides of the frame . The
frame should also be provided with fire rated EPDM smoke seal 12X12 mm conforming to
IS: 3614:2021 or as per test evidence... All provisions should be mortised & provided with
necessary inbuilt reinforcement to receieve appropriate hardware.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Frames should be provided with back plate bracket for anchor fastner with 8-10 mm dia
and minimum 80 mm long HDG fasteners, with Polyamide sleeves(Payable in extra item)
for installation of frame in finished plastered masonary wall opening. Note :- For grouting
of Steel frames in masonary installations ;cement sand mixture 1:3 ratio by civil
contractor/fire rated PU foam or such fire rated material may be recommended except
head member. Door leaf should be minimum 46mm thick fully flush double skin door.
Door leaf must be manufactured from 1.2mm(18gauge) thick galvanised steel sheet. The
infill material shall be mineral wool of minimum density 100 kg/cum. All doors shall be
factory prepped for receiving appropriate hardware and provided with necessary
reinforcement for hinges, locks, and door closers. The edges should be interlocked with a
bending radius of 1.4mm. For double leaf doors integrated astragals has to be provided on
the meeting stile for both active and inactive leaf. The shutters shall be mounted to the
frame with SS 304 grade ball bearing type hinges of size 100x 75x3 mm alongwith all
suitable hardware.Vision lite size 200x300 mm or 150 x 400mm(max area 0.06sqm)
wherever applicable should be provided with single layered clear fire rated glass panes as
per guidelines laid down under IS 3614 : 2021 vide clause no. 7.2.7 table no. 2 with a
clipon arrangement.The glass will be provided with fire rated ceramic tape of min.2 mm
thickness with min.15mm width alround on either face. Every Glass pane must carry a
permanent marking of its glass manufacturer Note:-As per drawings and design supplied
by architect and instruction given by authority and E.I.C.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and fixing Un-insulated fire rated GI Sheet doors conforming to FD
classification of IS 3614 :2021 with fire rating of 120 minutes integrity. The factory
manufactured door frame and shutter assembly shall be made out of minimum 1.20 mm
thick GI Sheet with minimum 120 GSM coating as per IS: 277. Door and frame should be
finished with powder coating in standard RAL shade finish having DFT of minimum
microns. The door should carry a minimum 500 Hrs of salt spray test. All accressesories
like hardware, vision panel, fire & smoke seal etc to be supplied by Fire door
manufacturer only as per the guidelines laid down in IS 3614:2021.Every door must carry
a label confirming to type of door & its fire rating. The door must carry a 5years valid test
evidence from CBRI-Roorkee / NTH-Kolkata/ NABL accrediated lab which operates in Rupees Five Thousand
accordance with ISO/IEC 17025.The Door frame shall be single rebate grooved profile of Four Hundred Thirty
size minimum 100mm x 57mm made out of 1.20mm (18gauge) minimum thick galvanized Three and Eighty Paisas
steel sheet. Frames shall be butt / mitered joint and field assembeled with bolting system. Only
Frames to have inbuilt grooved to accomodate Intumuscent fire seal strip 10X4MM, It
shall be fixed in grooves, specifically cut in rebate on all the 3 sides of the frame . The
frame should also be provided with fire rated EPDM smoke seal 12X12 mm conforming to
IS: 3614:2021 or as per test evidence... All provisions should be mortised & provided with
necessary inbuilt reinforcement to receieve appropriate hardware.Frames should be
provided with back plate bracket for anchor fastner with 8-10 mm dia and minimum
mm long HDG fasteners, with Polyamide sleeves(Payable in extra item) for installation of
frame in finished plastered masonary wall opening.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Note :- For grouting of Steel frames in masonary installations ;cement sand mixture 1:3
ratio by civil contractor/fire rated PU foam or such fire rated material may be
recommended except head member.Door leaf should be minimum 46mm thick fully flush
double skin door. Door leaf must be manufactured from 1.2mm(18gauge) thick galvanised
steel sheet. The infill material shall be resin bonded paper honey comb infill. All doors
shall be factory prepped for receiving appropriate hardware and provided with necessary
reinforcement for hinges, locks, and door closers. The edges should be interlocked with a
bending radius of 1.4mm. For double leaf doors integrated astragals has to be provided on
the meeting stile for both active and inactive leaf.The shutters shall be mounted to the
frame with SS 304 grade ball bearing type hinges of size 100x 75x3 mm alongwith all
suitable hardware.Vision lite size 300x400 mm or 150 x 800mm(max area 0.12sqm)
wherever applicable should be provided with single layered clear fire rated glass panes as
per guidelines laid down under IS 3614 2021 vide clause no. 7.2.7 table no. 2 with a clipon
arrangement. The glass will be provided with fire rated ceramic tape of min.2 mm
thickness with min.15mm width alround on either face. Every Glass pane must carry a
permanent marking of its glass manufacturer Note:-As per drawings and design supplied
by architect and instruction given by authority and E.I.C.
Lead Lined Doors:Providing and fixing Lead Lined Door of Navair make, comprising of
Hardwood Frames, interlayered with specified thickness of lead sheet and shutter
comprising with approved material as per manufacturer specification, the whole system
shall be in accordance to AERB norms. The lead sheet Overlaps in frame & edge to edge
lead lining in shutters must be considered as approved by EIC.Door Frame: The Door
Frames shall be hardwood red merandi Frame, The Frame Shall be fully lead lined of
MM lead Sheet with 99% purity and as defined by AERB. Frames should be fixed by Rupees Twenty Two
anchor fasteners for installation on a finished plastered masonry wall opening. The size Thousand Seven
147 68.00 Smt of frame shall be min. 120 X 70 mm or as per approved manufacturer standard, with 22725.00 Smt
Hundred Twenty Five
layered specified thickness of Lead Line Sheets (in door type) being overlapped from Only
either side, the finish of frame etc. shall be as per direction of Engineer in Charge. Frame
rebate shall be as per manufacturer standard, the finish of the door frame shall be wooden
primer finish as per EIC. The door frame shall be fixed with anchor fastener / dash
fasteners or as per manufacturer and as approved by EIC. Shutter: Door leaf shall be
mm thick with commercial ply & laminate both side with or without vision lite.incase
vision lite is required it shall be only Lead Glass as recomomnded by AERB/DRC .
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
The internal construction of the door should be rigid with lead line of 2mm thick all across
the inside of the exposed surface. Shutter shall be made with 6mm commercial borad and
35mm commercial board sandwitch between 2mm lead sheet. All doors should be factory
prepped for receiving appropriate hardware and provided with necessary reinforcement
for hinges, locks, and door closers as per ANSI Standard , the shutter shall be finished with
approved 1mm thick laminate both side. Hardware: The hardware shall be fire rated
hardware in accordance with requirement of doors and as specified in the door type in
the BOQ. The necessary reinforcement to be taken care if required while placement of
hardware. All the hardware shall be as approved by EIC and from approved makes only.
All hardware shall be with min. 2 years of warranty. Any miscellaneous items, accessories,
screws, sealant, seals, filler material etc. all to be consider to do the job and give full
solution. No complaint shall be entertained & no additional payment to be done. The
whole system shall be factory prepped, the approved manufacturer and prime contractor
shall ensure about the zero leakage with including all hardware & fixtures. Note:-As per
drawings and design supplied by architect and instruction given by authority and E.I.C.
6 MM Thick Clear Fire rated Glass saint gobain make 200x300mm Rupees One Thousand
148 30.00 Each 1666.50 Six Hundred Sixty Six and Each
Fifty Paisas Only
Mortise Shash Lock With SS Lever Handle Of SL7260/ TLH612 Becker F.S. Make Rupees Three Thousand
(Required For Service Room Loction Such As AHU, Electrical Rooms Etc.) Two Hundred Ninety
Two and Sixty Paisas
Mortise Dead Lock with 80mm cylinder body both side key DL7260 Becker F.S. Dead
Rupees Three Thousand
Lock Make. (Required For SERVICES Door Location)
150 30.00 Each 3075.45 Seventy Five and Forty Each
Five Paisas Only
SS D Type Pull Handle of 300mm mm Long of PHD2230 Becker F.S Make. Rupees One Thousand
151 30.00 Set 1676.60 Six Hundred Seventy Six Set
and Sixty Paisas Only
Door closers of BLC-604 Becker F.S Make. (Required For All Fire Doors Except Shaft Door) Rupees Two Thousand
Three Hundred Seventy
Three and Fifty Paisas
SS 304 grade 300mm Long Towe Bolt of Becker FS Make with necessary screws as Rupees Four Hundred
153 30.00 Each required. 414.10 Fourteen and Ten Paisas Each
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Anchor fastners of HILTI of maximum 120mm length. Rupees Sixty Five and
154 30.00 Each 65.65 Each
Sixty Five Paisas Only
Smoke seal 12x12mm Rupees One Hundred
155 50.00 Rmt 151.50 Fifty One and Fifty Paisas Rmt
Providing and laying integral cement based treatment for water proofing on horizontal
surface at all depth below ground level for under ground structures as directed by
Engineer-in-Charge and consisting of : (i) Ist layer of 22 mm to 25 mm thick approved and
specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement :
coarse sand) including applying of twice ( at base and top of mortar ) cement slurry @
2.2kg / m2 (each time) mixed with water proofing compound conforming to IS:2645 in
Rupees One Thousand
the recommended proportion over the leveling course (leveling course to be paid
156 3269.00 Smt separately). Joints sealed and grouted with cement slurry mixed with water proofing
1530.76 Five Hundred Thirty and Smt
Seventy Six Paisas Only
(ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand)
mixed with water proofing compound in recommended proportions.
(iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size
spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.
22.1.1 Using rough kota stone.
Providing and laying integral cement based treatment for water proofing on the vertical
surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed
with water proofing compound conforming to IS:2645 in recommended proportions with
a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the Rupees Two Thousand
gaps with neat cement slurry mixed with water proofing compound and finishing the
157 1327.00 Smt 2044.95 Forty Four and Ninety Smt
exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick Five Paisas Only
with neat cement punning mixed with water proofing compound in recommended
proportion complete at all levels and as directed by Engineer-in-charge :
22.2.1 Using rough Kota stone
Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: Rupees Two Thousand
8183, having density 48 kg/m3,50 mm thick,wrapped in 200 G Virgin Polythene Bags Seven Hundred Thirty
fixed to wall with screw, rawel plug & washers and held and in position by criss cossing GI Eight and Eight Paisas
wire etc. complete as per directions of Engineer in- Charge. Only
Providing and fixing in all exterior face panels breathable vapour barrier underneath the
Rupees One Hundred
cement fiber board as per National Building Code 2009 complete as per direction of
159 150.00 Smt 171.73 Seventy One and Seventy Smt
Engineer-in-charge.
Three Paisas Only
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Clearing and grubbing road land including uprooting rank vegetation grass Rupees Eighty Two
bushes,shrubs,sapling and trees girth up to 300 mm removal of stumps of trees cut earlier Thousand Two Hundred
and disposal of unserviceable materials(A) By manual means in area of light jungle Forty Nine and Eighty
Nine Paisas Only
Earthwork for embankment including breaking clods, dressing with all lead and lift and
Rupees One Hundred
including watering rolling and consolidation of subgrade in layers at O.M.C. to required
161 4500.00 Cmt dry density including filling the depression which occur during the process using power
162.58 Sixty Two and Fifty Eight Cmt
roller 8T to 10T.(C) From Borrow area within 1.0KM. lead
Providing and fixing C.I. Manhole cover 0.60 M. x 0.45M. size having weight not less than Rupees Nine Hundred
162 6.00 Each 35Kg. 958.17 Fifty Eight and Seventeen Each
Providing and fixing 0.70 Metre high fencing with M.S. Angle posts 40mm x 40 mm x6 mm
Rupees Three Hundred
and oil painting 3 coats fixed at 2.5 Mt,C/c. with five Horizontan lines and two diagonals of
163 650.00 Rmt. galvanised steel barbed wire weighting 9.38 Kg. per 100 Metre, strained and fixed to
323.20 Twenty Three and Rmt.
Twenty Paisas Only
Copping or Column etc complete.
Providing and fixing 1.9mt wide Cattle trap using M.S.I- beam of ISMB 150 section with Rupees Twenty
M.S. Angle 75x75x6 mm size on both ends and G.I. pipes 'c' class of 65mmdia with 60mm Thousand One Hundred
164 25.00 Smt. c/c rested on brick masonary wall 23cm thick with necessary excavation 15cm thick 20144.45 Smt.
Forty Four and Forty Five
1:3:6, 0.23x0.30 cm size beam & 10mm thick cement plastering etc. Paisas Only
Box cutting the road surface to proper slope and camber for making a base for road work Rupees One Hundred
165 2583.00 Cmt including removing the excavated stuff and depositing on the road side slope as directed 109.41 Nine and Forty One Cmt
upto 50Mt.lead. Paisas Only
Supplying and spreading of stone aggregate of an 40mm to 63mm Size machine cut of an
Rupees One Thousand
approved quality frm quarry site to site of work including loading unloading with all load
166 855.00 Cmt 1355.10 Three Hundred Fifty Five Cmt
and Ten Paisas Only
Supplying & Spreading of stone dust materials From out side borro area inqluding Rupees One Thousand
loading -anloading with all load and lift etc comp. Three Hundred Thirty
One and Twenty Five
Providing and fixing pre-cast Rubber Dye / steel Dye inter locking concrete block 60mm
thick with grade of concrete M300 pnumatic compressed / vibrated mechanically and as Rupees Seven Hundred
168 1680.00 Smt per approved design Confirming to IS 15658 : 2006 including 35 mm Sand layer for 704.07 Four and Seven Paisas Smt
levelling and filling the joint with sand in proper line and level as per guidlines of IRC : SP Only
63-2018 etc. Complete.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and fixing pre-cast concrete kerb stone of gray cement based concrete block
30cm length,30cm height and 15cm thick of M250 grade concret as per approved design Rupees Three Hundred
169 608.00 Rmt and including excavation for fixing in proper line and level,filling the joint with C:M 1:3 370.68 Seventy and Sixty Eight Rmt
(1cement:3fine sand) etc Paisas Only
Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure poluthene
Rupees Three Hundred
pipes of the following outside Dia. Low densidy, complete with special falnge compression
170 267.00 Rmt 339.05 Thirty Nine and Five Rmt
type fittings, wall clipsetc. including making good the wall ceiling and floor.(G)110 mm
Providing junction for rain water juncton chamber of size 0.60x0.60x0.75m with
excavation of size 1.96x1.96 m & 0.15m thick c.c.1:2:4 bed concrete including brick Rupees Eight Thousand
masonary wall in CM 1:6 of 0.75m height & 0.23m thick with 15mm thick cement plaster Nine Hundred Forty One
171 16.00 No inside & outside & 1.06x1.06 RCC (1:2:4) slab of thickness 0.15m with CRS steel and
and Fifty Three Paisas
0.60mx0.45m cast iron manhole cover with frame weight not less than 35 kg as per Only
directed by Engineer-in-charge
Providing Filter chamber of Brick work in C:M 1:6 of size 2.06mx1.20m x1.20m &
excavation dimension of 2.66mx 1.81x1.35m including C.C 1:2:4 bed concrete of 0.15m
thick including brick work in c.m 1:6 for 23cm thick wall including 15mm thick cement
172 4.00 No plaster inside & outside with cement slurry & 10cm thick RCC 1:2:4 top cover with frame 15716.14 No
Hundred Sixteen and
of minimum weight of 35 kg & filling filter material kapchi in layers (25-40mm & 10-
Fourteen Paisas Only
20mm) & BT metal 40mm & sand as per directed by Engineer-in-charge.
Providing Recharging pit of size 2.0m Dia.& 2.0m depth of water logging with excavation Rupees Thirteen
filling the pit with gravel & sand in layers including making 300mm dia bore depth of Thousand Two Hundred
173 2.00 No 4.5mt & above concrete with kapchi in layers (25-40mm & 10-20mm) & BT metal 40mm
Forty and Eighty Five
& filling brick as directed by Engineer-in-charge. Paisas Only
Providing and Laying ordinary cement concrete 1:2:4 (1- Cement 2- coarse sand : 4-
Rupees Six Thousand
graded stone aggregates 20 mm nominal size) and finishing smooth with curing etc.
Eight Hundred Eighty
174 21.07 Cmt complete including the cost of formwork but excluding the cost of reinforsement for R.C.C 6888.15 Cmt
Eight and Fifteen Paisas
work in (iii) Slabs having more than 10 cm and upto 13 cm. thickness
Const. of brick masonary chamber for under ground inspection chambers & bends with
Rupees Two Thousand
brick having crushing strength not less than 35 Kg. / cm² in C.M. 1:5 precast S.F.R.C top
Nine Hundred Thirty Two
175 8.00 Nos cover foundation concrete 1:5:10 in side plaster 15 mm thick with C.M. 1:3 finished 2932.93 Nos
and Ninety Three Paisas
smooth with floating coat of neat cement on walls & bed concrete, inside dimension 455x
610 mm and 450 mm deep for single pipe line.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Design, Construction ,Supplying, installing, testing & commissioning of Sewage Treatment
Plant of 50m3/day based on MBR technology (Excluding excavation, back filling &
disposal of surplus earth MS / Civil construction work) for the following duty: Nature of
Sewage - Domestic Sewage from Kitchen, Pantry and human waste for STP The sewage
treatment plant shall include the following items: Screen Chamber, Oil & Grease Trap,
Reaction Tank, Aeration Tank, Sludge Holding Tank, Air Blowers, Pump sets & other
equipment including submersible pumps in the drainage sump, Effluent, Sludge, Tertiary
Treatment, Irrigation, Flushing & Soft water pumpsets, Inlet connection from Raw Sewage
Tank, and Outlet connection to Treated water storage Tank with provision for overflow
piping to Discharge Channel. Electrical Control Panel & Cabling, earthing etc., Piping,
valves and Instrumentation including level controllers, pressure gages, sensors, Rupees Thirty Two Lacs
176 1.00 Nos rotameters and indicating cum recording meters for incoming sewage and outgoing 3295000.00 Ninety Five Thousand Nos
treated effluents etc.,Contractor shall ensure submission of detailed GA drawings (Plan & Only
Section), P&I diagram, schematic diagram for the above said components and equipment
and additional component if so required for the complete working of the STP /ETP. The
following list of civil units shall be in Client's Scope. However the size and design of the
civil constructions required shall be given and guaranteed for its efficacy by the
contractor for which the contractor shall take full responsibility, Bar screen pit, Oil &
Grease Chamber,Equalisation Tank,Sewage equalization tank/sump, Anoxic Tan,Aeration
Tank,Sludge Holding Tank, Final Traeted water tank,Drain Sump for STP room,The STP
shall consist of following units but not limited to these unit as may be required by the
manufacturer's design.
The STP shall be designed based on the following input sewage water parameters: Daily
average flow : 50 m3/Day PH : 6.5 - 8.5 , BOD5 : 50-
mg/l , S. Solids : 50- 80 mg/l , COD : 50- 80 mg/L , Oil &
Grease : 20-30mg/L , Required Parameters for Treated Water Output from STP
10 mg/l , COD : <= 50 mg/l , Oil & Grease : <= 10 mg/l , Amonical
Nitrogen : <= 10 mg/l , Total Nitrogen : <= 10 mg/l , Faecal Coiform :
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
ELECTRICAL INSTALLATION FOR SEWAGE TREATMENT PLANT Note : The mentioned
ratings are for estimation purpose it may change as per final technical submittal. The
Vendors are advised to quote as per actual. Design, fabrication, assembling, wiring,
supply, installation, testing and commissioning of motor control centre shall be fabricated
out of 14 gauge CRCA sheet steel in form in 3b formation with reinforcement of suitable
size angle iron, channel ‘T’ sections irons and /or flats wherever necessary. Cable gland
plates shall be provided on top as well as at the bottom of the panels. Panels shall be
treated with all anticorrosive process before painting as per specifications with 2 coats of
red oxide primer and final approved shade of powder coated paint. 2 Nos. earthing
terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall
also be provided in case of large panels. Approval shall be taken for each panel before
fabrication. Cadmium Plated hardware shall be used in fabrication of panels. Quoted rates
shall inclusive of cables, cable trays, control cabling, earthing (in accordance to
specification) with earthing from panel to each motor / equipment. MCC –1 (Sewage
Treatment Plant) Incoming 100 amps TPN MCCB with the following accessories: - 1 No
STP Describe as above item with complete in all respect. Operation & Manitenance
Contract for above STP for 1 year With Transportation and unloading of material at site
Providing and fixing in position cowel went to pipes.(B) 75mm dia. Rupees Three Hundred
177 3.00 Each 393.04 Ninety Three and Four Each
Providing and fixing in position cowel went to pipes.(C) 100mm dia Rupees Five Hundred
178 25.00 Each 505.17 Five and Seventeen Each
Providing and fixing screw down bib taps of following size.(B) Brass chromium plated Rupees One Hundred
179 90.00 Each screws down Bib Tap. (i) 15mm dia. 186.83 Eighty Six and Eighty Each
Three Paisas Only
Providing and fixing Gun metal check or non-return Rupees One Hundred
180 15.00 Each fullway wheel valve.(A) 15mm dia. 186.83 Eighty Six and Eighty Each
Three Paisas Only
Providing and fixing Gun metal check or non-return Rupees Two Hundred
181 20.00 Each fullway wheel valve.(B) 20mm dia. 203.82 Three and Eighty Two Each
Providing and fixing Gun metal check or non-return Rupees Four Hundred
182 35.00 Each fullway wheel valve.(C) 25mm dia. 420.63 Twenty and Sixty Three Each
Providing and fixing Gun metal check or non-return fullway wheel valve.(D) 32mm dia. Rupees Three Hundred
183 45.00 Each 314.73 Fourteen and Seventy Each
Three Paisas Only
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and fixing ball cock of approved. quality as Rupees One Hundred
184 2.00 Each directed.(B) Abonite (ii) 50mm dia. 137.89 Thirty Seven and Eighty Each
Nine Paisas Only
Providing and fixing G.I. Rain water spout of 50mm dia. and 30cm. length. Rupees One Hundred
185 10.00 Each 101.91 One and Ninety One Each
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE
Rupees One Hundred
having National Sanitation Foundation (NSF) seal for potable water of following dia.
186 450.00 Rmt nominal bore tube fittings and clamps including making good the wall, ceiling and floor
170.36 Seventy and Thirty Six Rmt
etc. complete.[A] 15 mm.
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE
having National Sanitation Foundation (NSF) seal for potable water of following dia. Rupees Two Hundred
187 305.00 Rmt nominal bore tube fittings and clamps including making good the wall, ceiling and floor 208.80 Eight and Eighty Paisas Rmt
etc. complete. [B] 20 mm. Only
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE
Rupees Two Hundred
having National Sanitation Foundation (NSF) seal for potable water of following dia.
188 245.00 Rmt 253.82 Fifty Three and Eighty Rmt
nominal bore tube fittings and clamps including making good the wall, ceiling and floor
Two Paisas Only
etc. complete. [C] 25 mm.
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE
Rupees Three Hundred
having National Sanitation Foundation (NSF) seal for potable water of following dia.
189 190.00 Rmt nominal bore tube fittings and clamps including making good the wall, ceiling and floor
338.24 Thirty Eight and Twenty Rmt
Four Paisas Only
etc. complete. [D] 32 mm.
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE
Rupees Four Hundred
having National Sanitation Foundation (NSF) seal for potable water of following dia.
190 155.00 Rmt 447.72 Forty Seven and Seventy Rmt
nominal bore tube fittings and clamps including making good the wall, ceiling and floor
Two Paisas Only
etc. complete. [E] 40 mm.
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE
having National Sanitation Foundation (NSF) seal for potable water of following dia. Rupees Six Hundred
191 115.00 Rmt nominal bore tube fittings and clamps including making good the wall, ceiling and floor 660.58 Sixty and Fifty Eight Rmt
etc. complete. [F] 50 mm. Paisas Only
Providing laying and jointing in true line and level 15mm dia. U.P.V.C. Pipe ( SCH- 40) for
cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed on the
wall with the help of clamp at every two metre C/C or shall be concealed as directed Rupees Seventy Two and
including necessary fittings etc. including testing of pipe and joints and fixing the same Sixty Five Paisas Only
with adhesive solvent, including cost of all materials.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing laying and jointing in true line and level 25mm dia. U.P.V.C. Pipe ( SCH- 40) for
cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed on the
Rupees Ninety One and
193 740.00 Rmt wall with the help of clamp at every two metre C/C or shall be concealed as directed 91.84 Rmt
Eighty Four Paisas Only
including necessary fittings etc. including testing of pipe and joints and fixing the same
with adhesive solvent, including cost of all materials.
Providing laying and jointing in true line and level 32mm dia. U.P.V.C. Pipe ( SCH- 40) for
cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed on the Rupees One Hundred
194 455.00 Rmt wall with the help of clamp at every two metre C/C or shall be concealed as directed 119.15 Nineteen and Fifteen Rmt
including necessary fittings etc. including testing of pipe and joints and fixing the same Paisas Only
with adhesive solvent, including cost of all materials.
Providing laying and jointing in true line and level 40mm dia. U.P.V.C. Pipe ( SCH- 40) for
cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed on the Rupees One Hundred
195 275.00 Rmt wall with the help of clamp at every two metre C/C or shall be concealed as directed 148.12 Forty Eight and Twelve Rmt
including necessary fittings etc. including testing of pipe and joints and fixing the same Paisas Only
with adhesive solvent, including cost of all materials.
Providing laying and jointing in true line and level 50mm dia. U.P.V.C. Pipe ( SCH- 40) for
cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed on the Rupees One Hundred
196 240.00 Rmt wall with the help of clamp at every two metre C/C or shall be concealed as directed 195.67 Ninety Five and Sixty Rmt
including necessary fittings etc. including testing of pipe and joints and fixing the same Seven Paisas Only
with adhesive solvent, including cost of all materials.
Providing, laying and jointing in true line and level 160 diametre U.P.V.C (Type B)
conforming to IS 13592-1992 with one end plain and other end socketed with rubber
ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe
line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall Rupees Eight Hundred
197 500.00 Rmt using of PVC clamp of the size 160 mm diametre x 210 mm length x 196 mm heigh at 834.38 Thirty Four and Thirty Rmt
every 2000 mm center to center or shall be concealed in walls as directed including Eight Paisas Only
necessary fittings such as bends, shoes etc. including testing of pipes and joints and
jointed with adhesive solvent cement including cost of all materials.
Providing, laying and jointing in true line and level 110 diametre U.P.V.C (Type B)
conforming to IS 13592-1992 with one end plain and other end socketed with rubber
ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe
line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall Rupees Eight Hundred
198 1170.00 Rmt using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at 856.03 Fifty Six and Three Rmt
every 2000 mm center to center or shall be concealed in walls as directed including Paisas Only
necessary fittings such as bends, shoes etc. including testing of pipes and joints and
jointed with adhesive solvent cement including cost of all materials.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 100 mm diameter with jali Rupees Five Hundred
199 80.00 Each of the following nominal diameter of self cleansing design with C.I scread down or hinged 572.32 Seventy Two and Thirty Each
grating including the cost of cutting and making good the walls. Two Paisas Only
Providing erecting and fixing double coated ISI water tank of required capacity each with Rupees Three and
all necessary fittings and connection etc. complete on terrace Ninety Five Paisas Only
Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber and water Rupees One Thousand
tight C.I. cover with frame of 300mm x 300mm size (inside) with standard weight.(i) Two Hundred Ninety
Square mouth traps. (A) 100mm x 100mm size P type. Two and Nineteen Paisas
Providing laying (to level or slopes) and jointing reinforced concrete Light duty non- Rupees Two Hundred
202 430.00 Rmt pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends 254.89 Fifty Four and Eighty Rmt
prepared for collar joints including testing of joints complete.(B) 150mm Nine Paisas Only
(I) Extra rate for constructing B.B. masonry for every additional depth of 0.1M. or Part Rupees Five Hundred
203 12.00 Each thereof over item No.24.27 (I) for depth from 0.9M to 1.5M. 522.96 Twenty Two and Ninety Each
Six Paisas Only
Providing and fixing cast iron steps of size 500mm x Rupees Two Hundred
204 120.00 Each 150mm x 22.5mm and painting with two coats of Anti corrosive paint etc. complete. 207.66 Seven and Sixty Six Each
Constructing brick masonry chamber for underground C.I. Inspection chamber and bends
with bricks having crushing strength not less than 35Kg/Cm2 in C.M. 1:5 C.I. cover with
frame (Light duty) 455mm x 610mm intenal dimensions total weight of cover with frame Rupees Two Thousand
to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top slabe Nine Hundred Thirty Two
205 25.00 Each with 1:2:4 mix (1 cement :2- coarse sand :4-graded stone aggregate 20mm size) 2932.93 Each
and Ninety Three Paisas
foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished Only
smooth with a floating coat of neat cement on walls and bed concrete etc. complete.(i)
Inside dimensions 455mmx 610mm and 450mm deep for single pipe line.
Extra over items 24.44 for every additional depth of 0.1M. of part thereof beyond 450mm Rupees Two Hundred
206 25.00 Each depth for Brick masonry chamber.(i) for 455mm x 610mm size. 242.39 Forty Two and Thirty Each
Nine Paisas Only
Constructing brick masonry chamber for underground C.I. Inspection chamber and bends
with bricks having crushing strength not less than 35Kg/Cm2 in C.M. 1:5 C.I. cover with
frame (Light duty) 455mm x 610mm intenal dimensions total weight of cover with frame
to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top slabe Rupees Three Thousand
207 20.00 Each with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm size) 3660.76 Six Hundred Sixty and Each
foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished Seventy Six Paisas Only
smooth with a floating coat of neat cement on walls and bed concrete etc. complete.(ii)
Inside dimensions 500mm x 700 mm and 450mm deep for pipe line with one or two
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Extra over items 24.44 for every additional depth of 0.1M. of part thereof beyond 450mm Rupees Two Hundred
208 20.00 Each depth for Brick masonry chamber.(ii) for 500mm x 700mm size. 264.86 Sixty Four and Eighty Six Each
Constructing brick masonry chamber for underground C.I. Inspection chamber and bends
with bricks having crushing strength not less than 35Kg/ Cm2 in C.M. 1:5 C.I. cover with
frame (Light duty) 455mm x 610mm intenal dimensions total weight of cover with frame
to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top slabe Rupees Seven Thousand
209 15.00 Each with 1:2:4 mix (1 cement :2- coarse sand :4-graded stone aggregate 20mm size) 7180.44 One Hundred Eighty and Each
foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished Forty Four Paisas Only
smooth with a floating coat of neat cement on walls and bed concrete etc. complete.(iii)
Inside dimensions 600mm x 850 mm and 450mm deep for pipe lines with three or more
Extra over items 24.44 for every additional depth of 0.1M. of part thereof beyond 450mm Rupees Three Hundred
210 15.00 Each depth for Brick masonry chamber.(iii) for 600mm x 850mm size. 325.59 Twenty Five and Fifty Each
Nine Paisas Only
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1 cement :2-coarse sand : 4-
graded stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-cement : 3-
coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement
Mortar 1:3 (1-Cement : 3-coarse sand) finished with a floating coat of neat cement and
making channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse sand :4-stone Rupees Eleven Thousand
211 24.00 Each aggregate 20mm nominal size) finished smooth complete including curing and festing (i) 11042.74 Forty Two and Seventy Each
Inside size 900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 560mm Four Paisas Only
diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg.
and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having
crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-
Coarse sand) (1) A type depth 0.90 Metre for 150mm diameter sewer.
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1cement :2-coarse sand : 4-graded
stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-cement : 3-
coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement
Mortar 1:3 (1Cement : 3-coarse sand) finished with a floating coat of neat cement and
making channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse sand :4-stone Rupees Nineteen
aggregate 20mm nominal size) finished smooth complete including curing and festing (i) Thousand Three
Inside size 900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 560mm Hundred Forty Nine and
diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. Sixty Three Paisas Only
and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having
crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-
Coarse sand) (2) B type depth 1.50 Metre for 150mm diameter sewer.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1cement :2-coarse sand : 4-graded
stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-cement : 3-
coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement
Mortar 1:5 (1Cement : 5-coarse sand) finished with a floating coat of neat cement and
making channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse sand :4-stone Rupees Twenty Three
aggregate 20mm nominal size) finished smooth complete including curing and festing (i) Thousand Four Hundred
Inside size 900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 560mm Seventy and Forty Eight
diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. Paisas Only
and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having
crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-
Coarse sand) (3) C type depth 2.25 Metre for 150mm diameter sewer.
Providing and fixing on platform stainless steel Sink glossy ASIS 304 grade x 1mm thick
with over all size 610x460mm & bowl size 560x410x200mm & SS Pillar cock with Rupees Nine Thousand
214 14.00 Each extention body like JAQUAR FUS-CHR-29021N including fixing the sink in platform & 9555.80 Five Hundred Fifty Five Each
making good the same including the cost of PVC waste pipe of 32mm dia. and PVC waste and Eighty Paisas Only
coupline etc complete as directed by EIC.
Providing and fixing Two way BIB cock with wall flange of genuine Jaquar ompany brand, Rupees Three Thousand
215 71.00 Each in with model no FUS-CHR29041, water tap brand or approved ISI brand quality, fixing 3131.00 One Hundred Thirty One Each
in pieline and testing the same… etc., complete., as directed by EIC Only
Providing and fixing wash down water closet European type WC pan (Wall Hung) like
JAQUAR CNS-WHT-961SPP- SIZE 365x545x360MM and P trap distance 23.5 cms with
integral P trap including jointing the trap with soil pipe in cement mortar 1:1 (1 cement : Rupees Twenty
1 find sand) including providing and fixing of 1) Health Faucet hand shower heavy duty Thousand Four Hundred
216 71.00 Each with SS braided hose 1.2 MT long pipe to water closet - JAQUAR ALD-CHR-573 with Single 20412.10 Each
Twelve and Ten Paisas
Piece Slim Concealed Cistern Body with Installations Kit & “S‐Type” drain pipe connection Only
set for Wall Hung WC (without Flush Control Plate) - JCS-WHT-2400S with Control Plate
Opal - JCP-CHR-152415,Toilet roll holder -Jaquar -ACN -1151N etc,complete
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and fixing Wash Basin vitreous china table top wash basin size 560mm x
mm in white colour. Like JAQUAR CNS-WHT-903 SIZZE OF 425x340x175MM with single
hole for pillar tape with CP or MS brackets painted white including cutting holes and
making good the same including (1) Providing and fixing SS waste coupling of 32 mm dia
size half theread with 80mm height like jaquar -ALD - CHR-705 for wash basin with
rubber plug (2) Providing and fixing SS bottle trap with internal partition of 32mm size
Rupees Thirteen
with 250mm &190mm long wall flange connection pipes and wall flange likejaquar ALD-
217 71.00 Each 13635.00 Thousand Six Hundred Each
769 L250X190 of approved quality with necessary fitting for wash basin (3) Providing
Thirty Five Only
and fixing SS Pillar cock with extention body like JAQUAR FUS-CHR-29021N with
necessary fittings etc. complete (4) Providing and fixing SS finish Angular Stop Cock
quarter turn like Jaquar code FUS-29053 with necessary fittings (5) Providing and fixing
SS finish soap dispenser with metallic bottle like Jaquar code-ACN-CHR-1135N,Towel ring
-jaquar-CAN-1121BN etc. complete
Providing and fixing Urinal of approved quality including connection with trap and with
integral longitudinal flush pipe.(A) Squating plate pattern white earthenware size of
urinal 370mm x 315x 620 mm.of jaquar make code no URS -WHT-132530 including (1)
Providing and fixing SS finish waste coupling of 32 mm dia size half theread with 80mm Rupees Fourteen
height like jauar -ALD - 709 for wash basin with rubber plug (2) Providing and fixing SS Thousand Five Hundred
finish bottle trap with internal partition of 32mm size with 250mm &190mm long wall Eighty Three and Thirty
flange connection pipes and wall flange like jaquar ALD-769 of approved quality with Nine Paisas Only
necessary fitting for wash basin (3) SS finish flush valve of auto closing system like jaquar
PRS-073 of approved quality and connection with waste pipe trap etc. complete
Providing and fixing Overhead Shower ø105mm Round Shape Single Flow with Air Effect
(ABS Body & Face Plate Chrome Plated) with Rubit Cleaning System JAQUAR OHS-1709 &
Shower Arm Casted 160mm Long Light Body Round Shape for Wall Mounted Showers
with Flange JAQUAR SHA-477 & Wall Mixer 3-in-1 System with Provision for both Hand Rupees Twenty Two
Shower and Overhead Shower Complete with 115mm Long Bend Pipe, Connecting Legs & Thousand Seven
Wall Flange (without Hand & Hundred Twenty Five
Overhead Shower) JAQUAR QQP-7281PM, Towel Rack 600mm Long without Hangers, Only
Stainless Steel JAQUAR ACN-1181FS approved ISI brand quality, fixing in pieline and
testing the same… etc., complete., as directed by EIC etc.
Providing and fixing U PVC SCH40 for cold water 20 mm dia (3/4)" Rupees Eighty Nine and
Eighty Nine Paisas Only
Providing and fixing PVC SWR pipes IS 13592 for Drain - 75 mmdia Rupees Three Hundred
221 660.00 Rmt. 386.83 Eighty Six and Eighty Rmt.
Three Paisas Only
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and fixing PVC SWR P- Trap IS 14735 for Drain -110x110 Rupees Three Hundred
222 71.00 No. 357.54 Fifty Seven and Fifty Four No.
Providing and fixing Gun metal check or non-return fullway wheel valve. (A) 50mm dia. Rupees Eight Hundred
223 6.00 No. 871.63 Seventy One and Sixty No.
Three Paisas Only
Providing laying and jointing PVC SWR pipes IS 13592 for Drain - 50 mmdia it's Rupees Three Hundred
224 380.00 Rmt. accessories. 337.34 Thirty Seven and Thirty Rmt.
Four Paisas Only
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm Rupees Five Hundred
225 8.00 No. diameter and weighing not less than 440 grams. 520.15 Twenty and Fifteen No.
Providing and fixing SS finish Angular Stop cock for wash basin like Jaquar code FUS- Rupees One Thousand
29053 Seven Hundred Forty
Two and Twenty Five
Providing and fixing Handicap wash down water closet European type WC pan (Wall
Hung) like JAQUAR CNS-WHT-961SPP- SIZE 365x545x360MM and P trap distance
cms with integral P trap including jointing the trap with soil pipe in cement mortar 1:1 (1
cement : 1 find sand) including providing and fixing of 1) Health Faucet hand shower Rupees Twenty Three
227 3.00 Each heavy duty with SS braided hose 1.2 MT long pipe to water closet - JAQUAR ALD-CHR-573 23533.00 Thousand Five Hundred Each
with Single Piece Slim Concealed Cistern Body with Installations Kit & “S‐Type” drain pipe Thirty Three Only
connection set for Wall Hung WC (without Flush Control Plate) - JCS-WHT-2400S with
Control Plate Opal - JCP-CHR-152415,Toilet roll holder -Jaquar -ACN -1151N, including
grab bar etc,complete
Construction Septic tank inside dimention of 3.00 m in length &1.50 m in width & 2.25 m
depth including excavating any type of soil as shown and mentioned in the
drawing,providing and laying 0.10 m thick plain cement concrete 1:4:8 ( 1 cement :
coarse sand : 8 graded stone agg.) 40 mm thick IPS flooring at bottom with brick
masonary 0.23 m thick walls CM 1:6 ( 1 cement : 6 coarse sand ) and intermediate half Rupees Forty Five
brick masonary CM 1:4 & RCC Top slabs 0.12 m thick in 1:2:4 (1 cement : 2 coarse sand : Thousand Three
4 graded stone agg) including reinforcement as per design and 15 mm thick cement Hundred Eighty Six and
plaster in CM 1:3 with floating coat of neat cement slurry inside, top and around tank Sixty Seven Paisas Only
below 15 cm on ground level, Also provide Two nos SFRC (Steel Fibre Reinforced
concrete) cover with frame (Medium duty) 455mm x 610mm internal dimensions etc
complete as per direction of Engineer in charge.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and constructing SOAK WELL of 2.00 m diametre and 6.00 depth including the
cost of all type of execavation, 23 cm thick Honey combed masonary in C.M. 1:6 (1cement : Rupees Twenty Five
6 sand) & top slab casting 12 cm thick R.C.C. 1:2:4 (1cement : 2 sand : 4 graded stone Thousand Nine Hundred
aggregate 20mm nominal size) and curing including cost of reinforcement etc. complete Twenty Nine and Seventy
as per detailed drawing and directed by Engineer in charge. Two Paisas Only
DOMESTIC WATER TREATMENT PLANT
Supply installation, testing and commissioning of dometic water treatment plant
comprising of Pressure sand filter, and softner Plant accrording to input water
quality/analysis. Water treatment plant consisting of FRP tank, filter media, resins, brine
tank, CPVC SCH 80 piping, isolation valves, instruments supports. The scope shall include
CPVC SCH 80 interconnection piping, Butterfly Cast Iron valves, NRV, instruments, Rupees Three Lacs Fifty
230 1.00 Set autoback wash arrangement, Brine preparation tank & agitator platform, 1 nos Agitator 353500.00 Three Thousand Five Set
require capacity and Ventury etc.complete the job .Scope shall also includes one month Hundred Only
operation including consumable and training for operation of staff.
Inlet Flow Range : 12.5 m3/hour.
Input Water Parameters: - As per Site
Output Water Hardness : < 50 PPM
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Centtrifugal Monoblock Transfer pump
Supplying, installing, testing and commissioning of centrifugal pumps Complete with SS-
316 casing, S.S 316 impeller and SS-316 shaft, C.I. Base CED (Cathode Electrode
Deposition) coating & head TEFC motor (with mechanical seal) driven by 415 V AC,
phase, 50HZ., motor running at 2900 rpm speed , dry run protection, antivibration paid,
pole Motor & IE3 Efficiency, shall be supplied with all accessories viz., base plate, coupling,
motor etc. complete. Contractor to submit performance curves and technical catalogue of
the proposed model for review and information.
Panel mounted microprocessor based multi pump controller with large graphical display
with VGA 240 x 320 pixels and IP 55 enclosure, diodes to indicate pump ready, earthing, Rupees One Lacs Fifty
231 1.00 Set pump running and fault condition, Cascade Operation. Each incomer and Outgoing feeder 151500.00 One Thousand Five Set
should be capable for protection against Overload, Short Circuit and Phase reversal Hundred Only
condition and shall be capable to communicate with other controllers following. The PLC
shall support MODBUS-IP communication for its compatability to intergrate with 3rd
party BAS system Controller shall authorise Read/Write command via BMS.All alarms
should be displayed in the controller. System should be equipped with dry running
protection. Indication of all type of faults / on-off status / electrical parameters shall be
available on panel and central IBMS monitors. On-off operation for all pumps shall be
available on BMS system. SITC of elctronic type low water level controler with LED panel
to operate pump (necessary contacts along with minium one PLC operated spare contacts
required), shall prevent the pump from dry running
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Mounting Height : 500mm from the bottom of Raw Water tank. Electronic type low,
Medium & High water level controller with LED panel to operate pump (necessary
contacts along with minimum one PLC operated spare contacts required),level controller
with operational mode as one pump working at Medium level and cut off at High level
complete the job. Mounting Height (Medium Level) : (Domestic Treated water Tank)
Mounting Height (Hight Level ): (Domestic Treated water Tank) with probe & all control
wiring from Pump room Panel to operate the system automatic/manual & shall prevent
the pump from dry running. Scope shall also include power and control cable of required
size, termination, cable tray from Pump to Control panel, control cable as whereever
required etc. complete the job.
Set of accessories such as GI C Class headers of suction and discharge for (working and
Standby pump assembly) with CED Coating, Gun Metal Isolation valves, Gun Metal non
return valves, pressure gauge with Isolation Valve of PN 10 etc. complete the job.
Capacity per pump - 12.5 m3/hour, Head - 30 mt, 1 Set = 2 Nos. Pump (1 Working +
Standby - cascade operation).
HYDRO PNEUMATIC SYSTEM FOR Domestic Water Distribution,
Variable Speed Hydro-booster System
Compact self contained Hydro-booster system comprising of following
SITC of In-line, vertical multistage, centrifugal clear water pumps with SS-304 casing, S.S
304 impeller and SS-304 shaft, C.I. Base CED (Cathode Electrode Deposition) coating &
head TEFC motor (with mechanical seal), dry run protection, antivibration paid, 2 pole
Motor & IE3 Efficiency. Vendor to submit performance curves and technical catalogue of
the proposed model for review and information.
Panel mounted microprocessor based multi pump controller with large graphical display
Rupees Two Lacs Two
232 1.00 Set with VGA 240 x 320 pixels and variable frequency drive (VFD) integrated in a single body, 202000.00 Set
pressure sensor transmitter, IP 55 enclosure, diodes to indicate pump ready, earthing,
pump running and fault condition, Cascade Operation. Each incomer and Outgoing feeder
should be capable for protection against Overload, Short Circuit and Phase reversal
condition and shall be capable to communicate with other controllers following. The PLC
shall support MODBUS-IP communication for its compatability to intergrate with 3rd
party BAS system. Controller shall authorise Read/Write command via BMS.System
should be capable to compensate for frictional losses at lower flows. All alarms should be
displayed in the controller.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
System should be equipped with dry running protection. Indication of all type of faults /
on-off status / electrical parameters shall be available on panel and central IBMS
monitors. On-off operation for all pumps shall be available on BMS system. Electronic type
low water level controller with LED panel to operate pump (necessary contacts along with
minimum one PLC operated spare contacts required), with probe & all control wiring
from Panel to tank to operate the system automatic/manual & shall prevent the pump
from dry running.
Scope shall also include power and control cable of required size, termination, cable tray
from Pump to Control panel, control cable as whereever required etc. complete the job.
Pre-charged diaphragm pressure vessel with interchangeable membrane, charging
connection, connected to outlet header with necessary flanges, gaskets, isolating valves,
nuts/bolts etc. complete (size of pressure vessel shall be as per manufacturer
recommendation). Set of accessories such as GI C Class headers of suction and discharge
for (working and Standby pump assembly) with CED Coating, Cast iron control valves,
Cast Iron non return valves, pressure transducers, pressure gauge with Isolation Valve of
PN 10 etc. complete the job.Require complete company fitted ready-to-connect packaged
Capacity per pump - 2.5 m3/hour, Head - 30 mt, 1 Set = 1 Nos. Pump (1 Working +
Standby - cascade operation), Location - UGT Pump Room
Supply, Installation, Testing and Commissioning of Electric driven Fire pump suitable for
automatic operation and consisting of following: complete in all respect as required.
a) Horizontal, centrifugal, end suction pump to ensure a minimum pressure of 3.5 kg /
sq.cm. at highest and farthest outlet at specified flow of 2280 lpm at 70 m. head
conforming to IS standards.
b) Casing - CI, Impeller-Bronze, Shaft - SS 410, Mechanical seal
c) Squirrel cage induction motor with suitable HP with synchronous speed 2955 RPM, Rupees Two Lacs Fifty
Suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, 258822.60 Eight Thousand Eight
233 1.00 Set Set
horizontal foot mounted type with Class-F insulation, Conforming to IS standards. Hundred Twenty Two
d) Common Base plat for Pump and motor and coupling, coupling guard, rubber bellows, and Sixty Paisas Only
anti-vibration arrangement, cables & other accessories as required for complete
Installation of pump set.
e) Cement concrete foundation with cement concrete plaster will be in civil
scope.Contractor has to provide foundation drawing to civil contractor.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Supply, Installation, Testing and Commissioning of Diesel Engine driven fire pump
(Standby Pump) suitable for automatic operation and consisting of following: complete in
all respect as required.
a) Horizontal, centrifugal, end suction pump to ensure a minimum pressure of 3.5 kg /
sq.cm. at highest and farthest outlet at specified flow of 2280 lpm at 70 m. head
conforming to IS standards.
b) Casing - CI, Impeller-Bronze, Shaft - SS 410, Mechanical seal Rupees Five Lacs Forty
c) Diesel Engine with suitable HP with synchronous speed 2300 RPM, diesel tank, battery, Five Thousand Eight
exhaust pipe with insulation, all required accessories. Hundred Seven and
Exhaust pipe will be as per manufacturer's standard. Three Paisas Only
d) Common Base plat for Pump and motor and coupling, coupling guard, rubber bellows,
anti-vibration arrangement, cables & other accessories as required for complete
Installation of pump set.
e) Cement concrete foundation with cement concrete plaster will be in civil
scope.Contractor has to provide foundation drawing to civil contractor.
Supply, Installation, Testing and Commissioning of Electric driven pressurization Jockey
pump suitable for automatic operation and consisting of following: complete in all respect
a) Vertical inline pump to ensure a minimum pressure of 3.5 kg / sq.cm. at highest and
farthest outlet at specified flow of 180 lpm at 70 m. head conforming to IS standards.
b) Casing - SS 304, Impeller-SS 304, Shaft - SS 304, Mechanical seal Rupees One Lacs Four
c) Squirrel cage induction motor with suitable HP with synchronous speed 2900 RPM, Thousand Five Hundred
235 1.00 Set Suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, 104529.95 Set
Twenty Nine and Ninety
horizontal foot mounted type with Class-F insulation, Conforming to IS standards. Five Paisas Only
d) Common Base plat for Pump and motor and coupling, coupling guard and other
accessories as required for complete installation of pump set.
e) Cement concrete foundation with cement concrete plaster will be in civil
scope.Contractor has to provide foundation drawing to civil contractor.
Supply, Installation, Testing and Commissioning of 150 mm dia. Pressure Gauge (for all Rupees Three Thousand
pipes) of range 0 - 15 Kg / cm² Polished Stainless Steel Case with positive seal against Seven Hundred Forty
weather, moisture & dust, with Glycerine filled, screwed, nipple, isolation valve, U-type Two and Five Paisas
stainless steel siphon tube and complete with necessary as required. Only
Supply, Installation, Testing and Commissioning of Pressure Switches for automation of Rupees Three Thousand
fire pumps. Pressure switches shall be SPDT type suitable for single phase supply with Three Hundred Thirty
diaphragm, IP 67 protection as required. Seven and Four Paisas
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Supply, Installation, Testing and Commissioning of the following sizes of flange jointed /
screwed / welded, M.S. Pipes of Class C (Heavy class) ISI marked including accessories
such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings
/ unions / bends / flanges/ wrapping coating for u/g pipes etc., and laying on the surface Rupees Four Thousand
238 20.00 Rmt. including painting with two coats of anticorrosive primer and two coats of approved red 4153.12 One Hundred Fifty Three Rmt.
enamel paint after laying and testing after Installation etc. as per specifications complete and Twelve Paisas Only
All fittings up to 50mm shall be forged and above 50mm shall be butt welded.
b) 150 mm dia. Rupees Two Thousand
Eight Hundred Eighty
Three and Fifty Five
c) 100 mm dia. Rupees One Thousand
Nine Hundred Fifty Three
and Thirty Four Paisas
d) 80 mm dia Rupees One Thousand
Three Hundred Seventy
and Fifty Seven Paisas
e) 65 mm dia Rupees One Thousand
242 305.00 Rmt. 1112.01 One Hundred Twelve and Rmt.
One Paisas Only
f) 50 mm dia Rupees One Thousand
243 390.00 Rmt. 1000.91 and Ninety One Paisas Rmt.
g) 40 mm dia Rupees Seven Hundred
244 420.00 Rmt. 760.53 Sixty and Fifty Three Rmt.
h) 32 mm dia Rupees Six Hundred
245 650.00 Rmt. 618.12 Eighteen and Twelve Rmt.
Rupees Four Hundred
246 2440.00 Rmt. 478.74 Seventy Eight and Rmt.
Seventy Four Paisas Only
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Supply, Installation, Testing and Commissioning of the following sizes of flange jointed /
screwed / welded, Underground M.S. Pipes of Class C (Heavy class) ISI marked including
accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers Rupees Two Thousand
/ couplings / unions / bends / flanges / wrapping coating 4mm thick / 150mm width as Five Hundred Ninety Two
247 185.00 Rmt. per IS:10221 etc., and two coats of anticorrosive primer and testing after Installation etc.
and Sixty Seven Paisas
as per specifications complete as required. Only
All fittings up to 50mm shall be forged and above 50mm shall be butt welded.
b)100mm dia. Rupees One Thousand
Eight Hundred Forty
Seven and Twenty Nine
Supply, Installation, Testing and Commissioning of C.I. Y type Strainer with S.S. Screen/SS Rupees Forty Thousand
304 having 1.2mm perforation with require accessories. Nine Hundred Forty Six
a) 200 mm Dia. and Forty One Paisas
Supply, Installation, Testing and Commissioning of C.I. Sluice valve (IS: 14846,PN 16) with Rupees Sixty Two
flanges, nut bolts, gaskets complete as required. Thousand Five Hundred
a) 200 mm dia. Sixty Seven and Forty
Eight Paisas Only
b) 150 mm dia. Rupees Twenty Six
Thousand Four Hundred
Fifty Three and Ninety
Two Paisas Only
c) 100 mm dia. Rupees Seventeen
Thousand Two Hundred
Fourteen and Forty Four
Rupees Eleven Thousand
Nine Hundred Ninety
Seven and Seventy Nine
e) 65 mm dia. Rupees Nine Thousand
Five Hundred Sixty Nine
and Seventy Five Paisas
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Supply, installation, testing and commissioning of C.I. Butterfly valve (IS:13095 , PN 16) Rupees Nine Thousand
with flanges, nut bolts, gaskets complete as required. Eight Hundred Sixty Four
a) 150 mm dia. and Sixty Seven Paisas
b) 100 mm dia. Rupees Five Thousand
Six Hundred Twenty
Eight and Seventy Three
c) 80 mm dia. Rupees Four Thousand
Two Hundred Seventy
and Twenty Eight Paisas
Rupees Three Thousand
258 1.00 Nos. 3333.00 Three Hundred Thirty Nos.
Supply, Installation, Testing and Commissioning of Cast iron Dual plate Check valve (PN
Rupees Ten Thousand
259 3.00 Nos. 10362.60 Three Hundred Sixty Two Nos.
and Sixty Paisas Only
Rupees Seven Thousand
260 1.00 Nos. 7615.40 Six Hundred Fifteen and Nos.
Forty Paisas Only
c) 65 mm dia. Rupees Five Thousand
Three Hundred Eighty
Two and Twenty Nine
Supply, Installation, Testing and Commissioning of Air vessel of size 450 x 2000 mm long
Rupees Sixty Thousand
fabricated from 8 mm thick M.S Plate and installed vertically on suitable legs. legs shall be
262 1.00 Nos. provided with M.S. plate of size 50mmx50mmx6mm at bottom with necessary
60830.28 Eight Hundred Thirty and Nos.
Twenty Eight Paisas Only
accessories. as required for complete installation.
Supply, Installation, Testing and Commissioning S.S. Fire Hydrant Single Landing Valve
Rupees Four Thousand
with 80 mm N.B. flanged inlet, SS spindle controlled 63 mm dia female instantaneous
Eight Hundred Twenty
263 38.00 Nos. outlet type. SS coupling, blank cap, chain, twist release type lug & all accessories 4821.74 Nos.
One and Seventy Four
Conforming to IS:5290. Including fixing with anchor fastener and flanged tapping from
wet riser complete as required.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Supply, Installation, Testing and Commissioning of Fire Hose Cabinet wall mounting type
Rupees Three Thousand
18swg (750 mm x 600 mm x 250 mm deep) with required accessories as per
Eight Hundred Seventy
264 36.00 Nos. specification. 3877.39 Nos.
Seven and Thirty Nine
Supply, installation, testing and commissioning non-percolating rubber reinforced lined
Rupees Three Thousand
Fire Hose pipe (as per IS : 636) of 63 mm dia and 1no.x15 mtrs long. The hose shall be
Nine Hundred Eighty
265 72.00 Nos. rated for burst pressure of 38 kg/sqcm. Hose shall be complete with ISI marked SS male 3984.45 Nos.
Four and Forty Five
& female coupling (IS:903) bound as per specification.
Supply, Installation, Testing and commissioning of 63 mm dia instantaneous pattern SS Rupees One Thousand
short branch pipe, 20 mm dia nozzle conforming to IS 903, suitable for inter connection Seven Hundred Ninety
to hose pipe coupling complete as required by the Local Fire Authority. Five and Seventy Eight
Supply, installation, testing and commissioning of First Aid Hose Reel conforming to Rupees Eight Thousand
IS:884 comprising of hose reel drum, 8 mm shut off nozzle, hose reel tubing type-2 as per Two Hundred Sixteen
IS: 444 of 25 mm dia x 36 mtr. long, painting, fixed wall type with fixing bracket, anchor and Thirty Five Paisas
fastener, bolts & nuts etc. complete as required by Local Fire Authority. Only
Supply, installation, testing and commissioning of forged brass Ball Valve. Rupees One Thousand
(PN 25) One Hundred Forty Four
a) 25mm dia and Thirty Three Paisas
Supply, Installation, Testing and Commissioning of 25mm Brass Sprinkler test and Drain Rupees Five Thousand
Valve (300 PSI) assembly with all required fittings as per drawing and as directed. Seven Hundred Twenty
Seven and Seventy One
Supply, installation, testing and commissioning of Cast Iron Four Way Fire Brigade Inlet as
Rupees Seven Thousand
per IS: 904 having 63 mm dia inlet with blank cap and chain with necessary fittings,
Seven Hundred Forty
270 1.00 Nos. flanges, nut bolts etc. complete as required. 7743.67 Nos.
Three and Sixty Seven
Supply, installation, testing and commissioning of Cast Iron Two Way Fire Brigade Inlet as Rupees Four Thousand
271 1.00 Nos. per IS: 904 having 63 mm dia inlet with blank cap and chain with necessary fittings, 4806.59 Eight Hundred Six and Nos.
flanges, nut bolts etc. complete as required. Fifty Nine Paisas Only
Supply, Installation, Testing and Commissioning of Gun Metal Air Release Valve with Rupees Two Thousand
272 4.00 Nos. necessary fittings. Size: 25 mm (For Riser) 2048.28 Forty Eight and Twenty Nos.
Eight Paisas Only
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Supply, Installation, Testing and commissioning of Quartzoid Bulb type Sprinkler Heads. Rupees Three Hundred
273 450.00 Nos. a) Pendent Sprinkler 57°C - K-80 - standard response - UL listed 317.14 Seventeen and Fourteen Nos.
b) Pendent Sprinkler with rossette plate 57°C - K-80 - standard response - UL listed
Rupees Four Hundred
Five and One Paisas Only
Supply, Installation, Testing and commissioning of Vane type Flow Indicating Switch with Rupees Five Thousand
fittings, Flanges, nut-bolts, washers etc. as per requirement. a)150mm dia. Four Hundred Fifty One
and Ninety Eight Paisas
b)100mm dia. Rupees Five Thousand
Four Hundred Fifty One
and Ninety Eight Paisas
c)80mm dia. Rupees Five Thousand
Four Hundred Fifty One
and Ninety Eight Paisas
Providing, fixing, testing & commissioning UL listed SS corrugated Unbraided Flexible
Rupees Seven Hundred
pipe, nominal Inlet by outlet 1"x ½" with required accessories to complete the
278 660.00 Nos. 780.73 Eighty and Seventy Three Nos.
b) Size: 1000mm Rupees Eight Hundred
279 660.00 Nos. 823.15 Twenty Three and Nos.
Fifteen Paisas Only
Supply, installation, testing and commissioning of Pump on/off Remote switches to each Rupees Six Hundred
280 27.00 Nos. internal hydrant valve with required accessories. 624.18 Twenty Four and Nos.
Eighteen Paisas Only
Supply, installation, testing and commissioning of XLPE insulated Flexible Cable with Rupees Two Hundred
281 600.00 Rmt. conduit from each Pump on/off switches to Panel with all necessary accessories. 238.36 Thirty Eight and Thirty Rmt.
Size: 4 core x 2.5 sq. mm Six Paisas Only
Supply, installation, testing and commissioning of Carbon Dioxide (Co2) type Fire Rupees Four Thousand
Extinguisher of 4.5 kg confirm to IS:15683, stored pressure, squeeze type with ISI marked Six Hundred Twenty Four
fitted with required accessories including wall suspension brackets. and Seventy Nine Paisas
Supply, installation, testing and commissioning of ABC (MAP 50%) type 6 kg stored
Rupees One Thousand
pressure, squeeze type confirm to IS:15683, with ISI marked fitted with required
283 47.00 Nos. 1925.06 Nine Hundred Twenty Nos.
accessories including wall suspension brackets.
Five and Six Paisas Only
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Supply and fixing of Clean Agent HCF236fa, 10 Kg modular type ceiling mounted Fire Rupees Thirty One
extinguisher , Stored pressure type with pressure gauge. Thousand Six Hundred
Sixty Eight and Fifty Five
Providing, fixing AUTO GLOW photo luminescent Signage's as per IS standard in Block / Rupees Three Hundred
285 23.00 Nos. Small Letters on rigid sheet with necessary wall or Ceiling fittings as Specified Sizes: a) 338.35 Thirty Eight and Thirty Nos.
Fire Equipment : size: 100 x 300mm Five Paisas Only
Proving required size of core-cutting in beam and RCC after to finished hole by proper Rupees Eight Hundred
286 80.00 Nos. solution or material . 858.50 Fifty Eight and Fifty Nos.
Supply Of Self Contained Rechargeable SWGS Emergency Egress Routes Lighting With the
1X 3 W LED Lamp. The equipment Shall Surface/hanging mounted with all require Rupees Three Thousand
Accessories with requirement for the Fire and Safety code of practice with 3 Hours Two Hundred Sixty Eight
backup. Nominal Input Voltage 230 +-10 % to 240V A.C. +-10 % 50 Hz +-10 % as specified and Thirty Six Paisas
in specification. Only
(Size:300 x 180mm)
10 x10 Oxygen Manifold with NRV, tail pipes and middle frame with chain as per Tender Rupees Three Lacs Fifty
288 2.00 Sets Specification attached. 350470.00 Thousand Four Hundred Sets
02+02 Cylinders Emergency Oxygen Manifold with NRV middle frame and High Flow Rupees Fifty Five
289 2.00 Sets Regulator without Rubber Diaphragm as per Tender Specification attached. 55001.57 Thousand One and Fifty Sets
Seven Paisas Only
Oxygen surface mounted Outlets NFPA/HTM Standard as per Tender Specification Rupees Five Thousand
290 180.00 Nos attached. (BS Metal Outlet) 5600.45 Six Hundred and Forty Nos
Five Paisas Only
Oxygen Flow Meter with Humidifier Bottle as per Tender Specification attached.
Rupees Three Thousand
291 180.00 Nos 3939.00 Nine Hundred Thirty Nos
Oxygen Probe as per Tender Specification attached. Rupees One Thousand
Two Hundred Ninety
Seven and Eighty Five
Compressed Air System as per Tender Specification attached.
Rupees Twenty Eight
Triplex System- Screw Air Compressors (Total Flow 4500LPM) with 15HP motors with
Lacs Fifty Four Thousand
293 1.00 Sets start/stop operations. 1 Nos. heatless dryer assy each having 175 cfm maximum capacity 2854063.05 Sets
Sixty Three and Five
along with 4 stage bacterial filter assy and single Receiver of 2000 liter water capacity,
nrv and Isolation valve, Gauges etc.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Surface Mounted Gas outlets for Medical AIR NFPA/HTM Standard as per Tender Rupees Five Thousand
294 90.00 Nos Specification attached. (BS Metal Outlet) 5600.45 Six Hundred and Forty Nos
Five Paisas Only
Suitable Probe for Medical Air gas outlets as per Tender Specification attached. Rupees One Thousand
Two Hundred Ninety
Seven and Eighty Five
Surface Mounted Gas outlets for Surgical AIR NFPA/HTM Standard as per Tender Rupees Five Thousand
296 90.00 Nos Specification attached. (BS Metal Outlet) 5600.45 Six Hundred and Forty Nos
Five Paisas Only
Suitable Probe for Surgical Air gas outlets as per Tender Specification attached. Rupees One Thousand
Two Hundred Ninety
Seven and Eighty Five
Vacuum Central System as per Tender Specification attached. Rupees Twenty Two
Complete Triplex Vacuum Vane Pumps set Model ----------- - (Total 2500 Flow LPM) with Lacs Thirty Eight
298 1.00 Sets Filter, interconnecting pipes, NRV, isolation valves, auto switch gear assy, exhaust 2238915.48 Thousand Nine Hundred Sets
silencer,bacteria filters and a single Receivers having – 1500 liters capacity Fifteen and Forty Eight
Surface Mounted Gas outlets for Medical Vacuum NFPA Standard as per Tender Rupees Five Thousand
299 90.00 Nos Specification attached. (BS Metal Outlet) 5600.45 Six Hundred and Forty Nos
Five Paisas Only
Vacuum Probe Suitable for Outlet as per Tender Specification attached. Rupees One Thousand
Two Hundred Ninety
Seven and Eighty Five
High Pressure Tubing as per Tender Specification attached. Rupees Two Thousand
301 90.00 Mtrs 2941.12 Nine Hundred Forty One Mtrs
and Twelve Paisas Only
Copper Pipe: - Lloyd's certified EN13348 as per Tender Specification attached. Rupees Eight Hundred
302 900.00 Mtrs 12x0.7mm Copper pipe 870.62 Seventy and Sixty Two Mtrs
15x0.9mm Copper pipe
Rupees One Thousand
303 1120.00 Mtrs 1242.30 Two Hundred Forty Two Mtrs
and Thirty Paisas Only
22x0.9mm copper pipe Rupees One Thousand
304 750.00 Mtrs 1068.58 Sixty Eight and Fifty Eight Mtrs
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
28x0.9mm Copper Pipe Rupees One Thousand
Seven Hundred Fifty
Three and Thirty Six
High flow piston Regulator IS/ ISO 7396 IS/ISO 10524-2 -2016 , IS/ISO 10524-4:2008 Rupees Twenty Eight
306 8.00 Nos HTM 02-01 ClassII b MDR 2017/745 28179.00 Thousand One Hundred Nos
Seventy Nine Only
Area Alarm Panel (Digital Illuminated LED - Microprocessor Based with Touch Function Rupees Twenty Nine
and Audio-Visual Indication) as per Tender Specification attached. 2 Gas Alarm Panel Thousand Three
307 8.00 Nos 29363.73 Hundred Sixty Three and Nos
Seventy Three Paisas
Isolation Valve: - with Nut & Nipple Type Brass Fittings/SS Flange, (no ferrule/copper Rupees Two Thousand
ring type brass fittings) as per Tender Specification attached. 15mm Isolation Valve Nine Hundred Seventy
Four and Forty Five
22mm Isolation Valve
Rupees Three Thousand
309 40.00 Nos 3444.10 Four Hundred Forty Four Nos
and Ten Paisas Only
28mm Isolation Valve Rupees Five Thousand
310 30.00 Nos 5040.91 Forty and Ninety One Nos
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Supply, Installation, Testing and Commissioning of 50 mm thick Pre Fabricated Modular
Operation Theater Panels (Walls and Ceiling) made out Polyurethane foam injected at
Kg/m3 sandwiched between 0.8 mm thick GP and SP sheet on front side and 0.5 mm GP
and SP/PPGI sheet on back-side. The inner surface walls be fixed to the bricks wall with
essential support. There will be minimum possible cavity/gap in between solid and steel
walls and will be variable to suit the architects lay out for the flush mounting of the
equipments. The wall and ceiling panels must comply with necessary provision of to JIS Z
2801/ISO 22196, BS EN 1363-1:2020, EN 1363-2:1999, EN 1364-1:2015, DIN 52210- Rupees Six Thousand
311 356.00 Smt 2:1984-08, DIN 4102-1, Class A2. Any Third-party compliance certificate mandatory. 6550.00 Smt
Five Hundred Fifty Only
Panel should be covered with protective sheath of 300 d.f.t Anti-bacterial Paint having
undergone Washability/Water resistance Test JIS K 5663.7.12, permeability test less than
200 unit of permeability, Anti-bacterial effect against staphyloccoccus aureus, Escherichia
coli (via HALO test) and safety and causative agents such as formaldehyde, toluene,
xylene, paradichlorobenzene etc. Third party (NABL approved Lab) certification for EGP
and thickness test certificate to be submitted
at time of supply.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Supply, Installation, Testing and Commissioning of Ceiling Filtration System - The ceiling
filtration system in the surgical theatre should ensure a unidirectional distribution of
sterile air, covering all areas affected by the airflow. It should consist of a laminar flow
system incorporated within a frame made from thick extruded aluminum profiles,
complete with a sealed gasket to prevent leaks. The system should incorporate "H 14"
class HEPA filters positioned in the ceiling plenum. These filters should achieve an MPPS
average efficiency greater than 99.95% and a 3-micron DOP efficiency greater than
99.99%. The filters should also be designed to handle a final pressure drop of no more
than 600 Pa, operate at a maximum temperature of 60 degrees Celsius, and function
effectively within a relative humidity range of 40-50%. The filtration ceiling system
should be capable of maintaining a constant airflow velocity of 0.25 m/s at the diffuser.
This should be accomplished through the use of a diffuser or flow equalizer that ensures
uniform and constant air distribution over the entire surface area. The structure holding Rupees Three Lacs
312 2.00 Nos. the filtration system, including the filter frames and top plenum, should be made from 390000.00 Nos.
Ninety Thousand Only
either aluminum or stainless steel. The system should be CE/UL certified and designed to
achieve an ISO 14644/1 classification of ISO 5, with a bacteriological class of B (5
CFU/m3) and particle decontamination kinetics CP of 5 minutes. After installation, the
system's performance should be validated by a third-party government-approved
environmental lab to ensure compliance with specified standards. A positive pressure
should be maintained inside the operating theatre to prevent contamination from
external air sources. The supplier should provide test certificates for the HEPA filters and
the laminar airflow systems from the original manufacturers. Furthermore, the size of the
laminar airflow system should be a minimum of 8 feet by 8 feet. Finally, the entire system
should meet CE/BIS certification standards, ensuring it adheres to both European and
Indian safety and performance regulations and including validation.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
The flooring within the surgical theatre should consist of a minimum of 2mm thick
antistatic seamless PVC, ensuring durability and safety. This floor should be smooth, non-
slip, and made from an impervious material with sufficient conductivity to dissipate static
electricity effectively, yet not so conductive as to risk electric shock to personnel. The PVC
used should be of very high quality, particularly designed for electrostatic charge
dissipation, and should not be less than 2 mm in thickness. The installation process should
utilize continuous rolls, and joints should be seamlessly welded using special PVC thermal
welding units with welding bars of the same color to ensure uniformity and prevent
contamination. The sheets should be highly durable, capable of resisting shocks,
indentations, and scratches. The conductive material should be uniformly impregnated
within the PVC as grains to enhance its antistatic properties. Additionally, the flooring
should be inert to body fluids, chemicals, and disinfectants, and remain unaffected by
temperature variations typical within an operating theatre. It should efficiently discharge
electric charges up to 2 kV, and the electrical resistance (point to ground) should be
Sq maintained within 2.5x10^4 to 5x10^6 ohms, ensuring no buildup of electrical charge Rupees Four Thousand Sq
Mtrs. beyond 100 volts. Floor installation should be performed by skilled workers from Two Hundred Fifty Only Mtrs.
accredited agencies authorized by the PVC sheet supplier. The installation should include
a conductive copper grid beneath the PVC sheet, supported by liquid epoxy compounds to
create a uniform and level surface. Copper strips should be made visible by grinding and
not project more than 0.5mm above the floor level to prevent damage to the PVC sheet,
with one earthing lead brought out from every 150 sq.ft area and attached to the main
earthing strip/ground. The flooring should also be mechanically shockproof, scratchproof,
flame retardant, and antimicrobial. Corners of the flooring should be uniformly curved,
and a concealed cove-former (aluminium) should overlap the wall panel to a height of
approximately 25mm and be sealed perfectly and uniformly. Before laying the PVC,
suitable self-leveling compounds should be used to prevent any undulations within the
operating theatre. The final surface should be non-corrosive to biological fluids and
detergents, with a color that is uniform, pleasant, and matching with the ambience as
approved by the respective consignee.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
The door to the surgical theatre should be a hermetically sealed, single sliding door
measuring 2.1 meters in height and 1.5 meters in width. The door should be equipped
with a controller capable of being operated by elbow switches, foot switches, and a
touchless sensor, providing multiple, accessible control options. The track for the door
should be made from stainless steel or aluminum, with the running surface for the top
rollers angled appropriately to minimize resistance and facilitate smoother movement.
The door leaf should be suspended using high-quality hard plastic rollers with double
bearings at the top. These rollers should run under the stainless steel or aluminum track
to ensure smooth and noiseless operation. The opening and closing mechanisms of the
door should be controlled by a microprocessor for precise electromechanical movement.
The material of the door should be either SMS or HPL, with a color that matches the
interior design. The door should be designed to be strong yet lightweight for ease of use.
In case the automatic mechanism fails, the door should still be able to open and close
effortlessly manually. The handle of the door should be made from stainless steel with a
matte finish and equipped with a high-quality cylindrical or ESPg lock for security. The
door leaf should incorporate a high-quality synthetic rubber gasket with long durability 295000.00 Rupees Two Lacs Ninety
314 4.00 Nos. Nos.
to ensure hermetic sealing and maintain a 99.99% air tightness at a minimum pressure of Five Thousand Only
75Pa. The floor on either side of the door should be perfectly level, with a maximum
permissible difference of +1mm, to avoid any tripping hazards or unsealed gaps. The
overall thickness of the finished door should range from 30-60mm, with the inner part of
the door filled with CFC-free polyurethane foam, approximately 48mm thick, sealed
airtight to block any microbial ingress. The door and its controls should comply with IEE
regulations, utilizing DC brushless or PMDC motors that are effectively isolated from
mains power to ensure safety and reliability. Additionally, the door should include a
vision window measuring 300mm x 300mm, featuring double-glazed panels that are
hermetically sealed to maintain the integrity of the seal. The movement of the door should
be as quiet as possible, and the time to start moving after receiving a signal should be
adjustable between 0.5 to 20 seconds.The door controller should be CE marked, BIS
certified, or IEC 60601 certified to meet international and national safety standards. A test
certificate for the hermetically sealed door frame should be included in the pre-dispatch
documents to verify compliance with the specified standards and functionality.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Supply, Installation, Testing and Commissioning of Membrane-Type Operation Switch and
Communication Controller - The Operation Switch and Comms Controller should
encompass all necessary controls to ensure the proper operation and monitoring of
equipment and services in the operating room (OR). Positioned for optimal visibility in
the surgeon's line of sight and the OT staff, the wall-mounted membrane-buttons should
be easily accessible to the nurse for operation and assistance. In addition to hosting a
digital clock and elapsed time indicator, the panel should feature a medical gas alarm,
clearly indicating high and low gas pressures for each gas service, including vacuum,
supported by an audible alarm. The Operation Switch and Comms Controller should also
provide an alarm mute option for fault annunciation, with pressure sensors strategically
located near isolation valves. Controls for general lighting, including ON/OFF and 195000.00 Rupees One Lacs Ninety
315 2.00 Nos. Nos.
dimming, organized in groups for uniform illumination, should be present. Furthermore, Five Thousand Only
the panel should facilitate control over operating lights (major and satellite) and camera
functions (on/off and intensity). A hands-free telephone set with memory should be
conveniently situated, and temperature and humidity controls for the room, linked to the
AHU (+/5%) using NO/NC or Chilled Water/Hot Water Actuator Control Valve (whichever
is applicable), should be adjustable from the Operation Switch and Comms Controller.
Real-time indicators, such as a digital room pressure indicator and HEPA filter bank
differential pressure indicator, are essential for monitoring and maintaining a safe and
controlled environment in the operating room. Telephone with Alpha-numeric keyboard
is required with Speed-dialing option
Hatch boxes should be provided in each operating theater to facilitate the safe and
efficient removal of waste materials to the dirty linen area or adjacent corridor. Each
hatch box should be equipped with two doors, operated electrically or motorized,
designed such that only one door can be opened at a time to prevent cross-contamination.
Rupees One Lacs Fifteen
316 2.00 Nos. UV lighting should be installed to ensure sterilization and should remain on when both 115000.00 Nos.
doors are closed, automatically turning off when either door is opened. Indicators should
be provided on both sides of the operating theater to monitor the door open/close status.
The material of the hatch box should also be SS304 grade stainless steel, with a minimum
size of 600mm x 600mm.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
In each operating theater, an operating list board should be installed. It should be made of
ceramic with magnetic properties and should be flush with the wall to maintain
cleanliness and ease of use. LED type flat panel X-ray viewing panels should be provided,
complying with relevant electrical safety codes, and mounted flush with the wall to Rupees Twenty Eight
prevent dust accumulation and microbial growth. The body should be made of extruded
317 2.00 Nos. 28500.00 Thousand Five Hundred Nos.
aluminum, powder-coated with a bacteria-resistant and disinfectant-resistant finish. The Only
diffuser on the front panel should provide a uniformly lit screen, and dimming controls
should be easily accessible. Additionally, a proper spring-loaded film clip with rollers
should be included to securely hold and easily remove films without causing scratches.
LED type flat panel X-ray viewing panel should be supplied. This should comply with
relevant electrical safely codes. This should be a 2-panel viewing screen. Mounting should
be flush with the wall to avoid dust accumulation and growth or organisms between wall
and panel. Body should be of extruded aluminium powder coated black with bacteria Rupees Forty One
318 2.00 Nos. resistant and disinfectant resistant finish. The diffuser on the front panel should be a 41500.00 Thousand Five Hundred Nos.
uniformly lit screen. Dimming electronic control should be enclosed at the bottom of the Only
cabinet. Proper spring-loaded film clip with rollers should be provided to hold the films
firmly and to remove the film without scratches
Supply, Installation, Testing and Commissioning of Double-Bay Scrub Sink - The scrub
station should be compact, designed for use in the OT complex, and facilitate pre-
procedural scrubbing. It should be made from heavy gauge type 304 stainless steel with a
minimum thickness of 1.5mm and feature seamless welded construction polished to a
satin finish. The scrub sink should have a front access panel for easy maintenance of Rupees One Lacs
319 2.00 Nos. water control valves, waste connections, stoppers, and strainers. Hands-free operation 126000.00 Twenty Six Thousand Nos.
should be enabled through infrared sensors with programmable adjustments. Only
Thermostatic mixing valve control should maintain constant water temperature and be
located behind the access panel. Timing should be adjustable to meet individual usage
requirements, and units should have reduced anti-splash fronts. An additional knee/foot-
operated switch should also be provided for enhanced functionality.
Supply, Installation, Testing and Commissioning of Storage Units - Storage units should be
constructed with same material, as wall and ceiling panels. The shelves, made of glass and,
should be removable for cleaning. The unit should be divided into two or more parts, each Rupees Eighty Five
320 4.00 Nos. with individual glass doors equipped with a high-quality locking system. The overall size 85000.00 Nos.
of the storage unit should
be approximately 200 cm (H) x 120 cm (W) x 35 cm (D).
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Supply, Installation, Testing and Commissioning of Peripheral Lighting - To enhance the
operational environment of each operating theatre, peripheral lighting and clean room
luminaries should be installed, with a minimum of eight units per theatre. These lights
should offer an intensity of at least 500 Lux and be housed in highly specular anodized
aluminum with an optical antiglare system to minimize visual fatigue and glare. Each
peripheral light should measure 2' x 1'. The covers for these luminaries should be
constructed from highly resistant, disinfectant-proof laminated safety glass or acrylic,
featuring a stylish, fine-grained surface that complements the clean and sterile
environment of the operating theatre. The body of the luminaries should be made from
sheet steel, perfectly powder-coated to resist contamination and facilitate easy cleaning,
and should be ready for connection either as individual units or within a series circuit. Rupees Twelve
This setup should include digital electronic control gear utilizing multilamp technology to Thousand Only
optimize energy efficiency and light output. The installation of these luminaries should
ensure that the recess frames are gas tight. Each fitting should be flush with the ceiling
and designed to be removable from either the top or bottom for ease of maintenance. It is
crucial that the light fittings are uniformly and aesthetically distributed across the ceiling
to provide consistent illumination throughout the OT, without interfering with visibility
during procedures such as green mode endoscopy. Furthermore, the peripheral lighting
system should conform to IP65 or IP54 international protection ratings, ensuring that the
fixtures are dust tight and protected against water ingress, suitable for the demanding
conditions of an operating theatre.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Supply, Installation, Testing and Commissioning of Electrical Wiring inside OT - Power
distribution within each Operating Theatre (OT) should be handled via distribution
boards located locally to each theatre using Fire Resistance Low Smoke Wiring, layed in
PVC conduits of reputed brand. The sub mains power to these panels should be provided
by the general electrical contractor, and all distribution services within the departments
should run from these panels. The power distribution unit should hold certifications such
as EN, CE, FDA, IEC, and BIS to ensure compliance with international safety and
performance standards. Each wall of the MOT should have a minimum of two hybrid
switch sockets (6/16A) on each wall, in compliance with IEC standards. Light fittings
within the clinical areas should be recessed LED types equipped with control gear and
sealed in accordance with the IP54 standard. This standard ensures that the fittings are
protected against limited dust ingress and water spray from all directions, suitable for
clinical environments. All equipment should be fully and permanently labeled to clearly Rupees Two Lacs Ninety
identify and describe the function, operation, and voltage of the apparatus concerned. Nine Thousand Only
Upon completion of the electrical installation, tests should be carried out in accordance
with the relevant sections of local wiring regulations, with results duly recorded. Each OT
should have a distribution board (DBs) installed, with suitable wiring. A separate
enclosure should house all high-voltage equipment to ensure safety and isolation. The
remote cabinet should contain operating lamp transformers, mains failure relays, UPS,
electrical distribution equipment, and circuit protection equipment for all circuits within
the operating theatre. All internal wiring within the DBs should terminate in connectors
equipped with screws and clamp springs. Connections should be of the clip-on type
mounted on a rail approved by CE/IEC/BIS standards and labeled with indelible
proprietary labels. All internal circuits should be protected by individual fuses or
miniature circuit breakers to ensure safety and manage potential electrical faults
AIR HENDALING UNIT Make:KrVelocity: Not More Then 10 mt/second. , Canvass
Connection-Heavy duty, non partical shreding,Fire Retardentuger,Nikotra only , Type:
PLUG,Drirect Driven,Dynamically Balanced Selection of fan-Should run comfortably at
HZ at rated capecity. Motor Make:Siemence,B.B,Crompton,ABB , Type:TEFC, IP:55, Foot
Mounted, VFD compitable and I2 generation Safety: Motor should have interlocked with
Rupees Twelve Lacs
AHU Motor door/excess/Fire DamperType-TWO TIRE, Floor Mounted , Inner
323 2.00 job const.:0.6mm plain G.I , Outer const.:0.8 mm G.I. Pre coated / Powder coated Thickness of
1225000.00 Twenty Five Thousand job
Insulation: 25mm,PUF injected having density 40 to 42 kg/m3. ,Colour:As approved by
CLIENT CONDENSING UNIT :
Condensing unit for AHU with all assesories and instalation (Copper pipie provide 3 mtr
Only Extra will charged extra) consider 1200 sqfeet insulation and ducting
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Double Dome OT Light with Ceiling mounted Double Dome LED OT lights having following
features and enclosed technical specifications, having Mobile App Connectivity, Battery
-Light intensity Ec - 160 000 & 160 000 lux, - Light intensity adjustment - 10 – 100%
(using Digital Capacitive Touch (Fully Remote Controlled)
- Color temperature Tc (with adjustment)
-Light field diameter d10 at Ec - 100 - 150 mm
-Working range - 1 m
-Color rendering index 93Ra Rupees Three Lacs
- Focusing Preset: Adjustable Ninety Thousand Only
- LED Average life - 50000-60000 hrs
- Diameter of Light - not less than 650 mm per dome
- Power Consumption - not more than 120W
OT Light should be BIS marked; manufacturer should have CDSCO License for this product
under Class A, Compliant to IEC standards such as IEC60601-1:2005+A2:2020, IEC 60601-
2-41:201 (Relevant Test Certificates to be submitted with Bid) Clause-wise Technical
Compliance to be.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Single-arm surgery/anesthesia pendant designed for Operating Theatres should feature a
compact, modular configuration to meet the precise requirements of hospitals, enabling
customization to suit specific operational needs of both Operating Theatres and Intensive
Care Units. It should be equipped with robust ceiling support capable of mounting a
selection of arms. The extension arm, pivotal for functionality, should allow horizontal
movement with a radius of 800-900mm and provide a level rotation ranging from 0 to
330/340 degrees, with both the extension arm and terminal box designed to rotate
together and independently for maximum versatility. The pendant should support a net
loading capacity of min. 100 kg, accommodating a variety of medical instruments and
devices securely. For medical and electrical services, it should offer configurations that
include at least two oxygen outlets, two vacuum outlets, one medical air, one medical air
at 7 bar, and an optional nitrous oxide outlet (In-scope of MGPS vendor) Additionally,
there should be six main sockets, each capable of supporting 5 to 15 amps, conforming to Rupees Two Lacs Eighty
325 2.00 Nos. universal standards to facilitate the operation of various medical and electronic devices. 284000.00 Nos.
Four Thousand Only
In terms of materials and construction, the pendant should be crafted from high-strength
aluminum alloy with a sealed design to enhance durability and maintain sterile
conditions. The arm itself should be made from high-density aluminum alloy extrusion,
ensuring both strength and reliability. Installation of the pendant should be ceiling-
mounted to provide a reliable and firm setup, optimizing space usage in the Operating
Theatre or ICU while seamlessly integrating with existing medical systems for managing
medical gas, electrical services, data communication, and equipment. Additionally, the
pendant should include practical features such as a stainless steel IV pole and a ward
vacuum unit clamp to further enhance its utility in a medical setting. With a net weight of
approximately 105 kg, accessible by the equipment carrier, the pendant should be robust
yet manageable, ensuring it meets the rigorous demands of modern medical
Providing and fixing UPS (25KVA) Of Good Quality as directed by engineer incharge Rupees Three Lacs
326 2.00 job 375000.00 Seventy Five Thousand job
Medical Gas Pipe Line Of Required dia for OT oxygen , Vaccum , Air.. Etc reuired
Point(from existing line ) as directed by engineer incharge from Outer Nearest Passage to Rupees Three Lacs Forty
327 2.00 job OT Pendant Rate Including , Alarm , Valve (for all line) , Point ,Flowmeter and Probe . if 345000.00 job
Five Thousand Only
alredy then no payment given
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both
are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr
length , in below type of pipe erected with 6A Modular type switch / bell push &
accessories and earth continuity of following type, erected on PVC / Metallic/Wooden Rupees Four Hundred
328 1351.00 Ea. box, single mounting base frame covered with textured/metallic/white front plate 485.81 Eighty Five and Eighty Ea.
modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp One Paisas Only
holder/ceiling rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling
complete. Cat. III
Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of .ISI
marked 1.1 KV Grade FRLS PVC insulated multi strand copper wires up to 10 mtr length,
in below type of pipe erected with 6A Modular type switch and hum free EME step type
electronic fan regulator mounted and accessories with earth continuity of following type Rupees Six Hundred
329 533.00 Ea. erected on PVC / Metallic/Wooden box, single mounting base frame covered with 674.68 Seventy Four and Sixty Ea.
textured/metallic/white front plate modules erected on / in wall / ceiling as per pipe Eight Paisas Only
erected. with necessary ceiling rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling
complete. Cat. III
Point wiring for Modular secondary light point with 2-1.5 sq.mm & earth wire of
sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand
copper wires, in below type of pipe to be erected complete with earth continuity and
necessary connection with primary light with accessories erected on Metal / PVC / Rupees One Hundred
330 751.00 Ea. wooden box covered with 3 mm thick PC(Polycarbonate) / Acrylic sheet for open / 167.66 Sixty Seven and Sixty Six Ea.
concealed wiring. with necessary Lamp holder / ceiling rose / H.D.Connector as directed. Paisas Only
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length,
in below type of pipe erected complete with Modular type switch & 5 pin Plug erected on
PVC / Metallic/Wooden box covered with appropriate front plate modules erected on / in
Rupees Five Hundred
331 131.00 Ea. wall / ceiling as per pipe erected with following type of accessories. 510.05 Ea.
Ten and Five Paisas Only
[I] For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu. Wire from nearby switchboard/mcb
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling
complete. Cat. III
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
[II] For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu. Wire from mcb db board. Rupees Seven Hundred
332 791.00 Ea. (f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling 745.38 Forty Five and Thirty Ea.
complete. Cat. III Eight Paisas Only
[III] For 16A Plug and 16 amp switch with 2-4 sq.mm Cu. Wire with 2.5 sq.mm ( green) Rupees Eight Hundred
333 148.00 Ea. earthing wire from mcb d b board.(f) with medium class Rigid PVC pipe and accessories 871.63 Seventy One and Sixty Ea.
erected concealed in wall/ceiling complete. Cat. III Three Paisas Only
Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin socket
erected on PVC / Metallic/Wooden box, single mounting base frame covered with Rupees Two Hundred
334 877.00 Ea. textured / metallic/white front plate modules erected on / in wall / ceiling with 257.55 Fifty Seven and Fifty Five Ea.
following type accessories. Cat. III(f) with medium class Rigid PVC pipe and accessories Paisas Only
erected concealed in wall/ceiling complete. Cat. III
Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earth wire of
sq.mm (green) both are of .ISI marked 1.1 KV grade FRLS PVC insulated multi strand
copper wires erected in below type of pipe with 6A Modular type switches and following
type of accessories erected on PVC / Metallic/Wooden box, single mounting base frame Rupees Six Hundred
335 158.00 Ea. covered with textured / metallic/white front plate modules erected on / in wall / ceiling 603.98 Three and Ninety Eight Ea.
as per pipe erected. with necessary batten/angle holder or ceiling rose or H.D.Connector Paisas Only
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling
complete. Cat. III
Providing following type of Modular Type Accessories mounted with PVC /
metallic/Wooden box, single mounting base frame covered with textured / metallic/white
Rupees One Hundred
front plate , modules erected with necessary connections as per site situation directed by
336 62.00 Ea. Engineer In charge.
160.59 Sixty and Fifty Nine Ea.
(3) Two Pin/RJ-11 Telephone Socket
[A] For One Gang
(7) Blank Plate Single. Cat.III
Rupees Twenty Five and
Twenty Five Paisas Only
(8) Computer RJ-45 socket . Cat.III Rupees One Hundred
338 62.00 Ea. 160.59 Sixty and Fifty Nine Ea.
(4) TV Co-axial Socket outlet Rupees One Hundred
339 10.00 Ea. 160.59 Sixty and Fifty Nine Ea.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete
to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes
Rupees Thirty Three and
340 9809.00 Mtr. fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as 33.33 Mtr.
Thirty Three Paisas Only
(c) 32 mm Rupees Fifty Four and
Fifty Four Paisas Only
Providing & erecting PVC Corrugated Flexible Conduit with required nos. of coupling, PVC Rupees Twenty One and
bushes, Check-nuts etc. complete of following sizes.(2) 25 mm Twenty One Paisas Only
Supplying and laying UPVC cable trunking system comprising unplasticised polyvinyl,
chloride rigid material with ignition free and flame proof confirming BS with necessary Rupees Four Hundred
343 180.00 Mtr. end caps Internal and external bend, flat bends, coupler, tee etc..All necessary accessories 428.24 Twenty Eight and Twenty Mtr.
and measuring of following sizes. Four Paisas Only
(2) 100 mm x 50 mm trunking
(4)100 mm x 50 mm trunking with TWIN compartment With clip in divider Rupees One Thousand
Three Hundred Twenty
Two and Nine Paisas
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded
Copper conductor wire in following type of pipe to be erected concealed in /flushed on
wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of Rupees Sixty Two and
345 3860.00 Mtr. green colour for earth continuity of following size.
Sixty Two Paisas Only
(A) With medium class Rigid PVC pipe and accessories.
(a) 2 wire 1.5 sq. mm
(b) 2 wire 2.5 sq. mm Rupees Eighty Two and
Eighty Two Paisas Only
providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded
Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with Rupees One Hundred
347 6430.00 Mtr. 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth 112.11 Twelve and Eleven Paisas Mtr.
continuity of following size Only
(a) 2 wire 4 sq. mm
(g) 4 wire 4 sq. mm Rupees One Hundred
348 755.00 Mtr. 180.79 Eighty and Seventy Nine Mtr.
(h) 4 wire 6 sq. mm Rupees Two Hundred
349 542.00 Mtr. 260.58 Sixty and Fifty Eight Mtr.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
(i) 4 wire 10 sq. mm(use earth wire of 4 sq.mm ) Rupees Four Hundred
350 120.00 Mtr. 425.21 Twenty Five and Twenty Mtr.
One Paisas Only
Providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded,
annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC -
Rupees Thirty Seven and
351 300.00 Mtr. 227 erected in existing pipe of following size (Specifically for control panel, relays, power 37.37 Mtr.
Thirty Seven Paisas Only
switchgears, motor starters & control wiring) with required size of copper lugs, nuts and
bolts if required. (d) One wire 4.00 sq. mm
(e) One wire 6.00 sq. mm Rupees Fifty Six and Fifty
Six Paisas Only
(f) One wire 10.00 sq. mm Rupees Ninety One and
Ninety One Paisas Only
(g) One wire 16.00 sq. mm Rupees One Hundred
354 100.00 Mtr. 142.41 Forty Two and Forty One Mtr.
(h) One wire 25.00 sq. mm Rupees Two Hundred
355 150.00 Mtr. 236.34 Thirty Six and Thirty Mtr.
Four Paisas Only
(j) One wire 50.00 sq. mm Rupees Four Hundred
356 100.00 Mtr. 448.44 Forty Eight and Forty Mtr.
Four Paisas Only
Supplying and erecting Flexible PVC insulated multi strand multi core 1.1 kv grade ISI
Rupees Thirty One and
357 105.00 Mtr. marked copper wires of following size to be erected as directed. 31.31 Mtr.
Thirty One Paisas Only
(d) 1.50 Sq.mm 2 core round PVC sheathed
(h) 2.50 Sq.mm 3 core round PVC sheathed Rupees Seventy Seven
358 169.00 Mtr. 77.77 and Seventy Seven Paisas Mtr.
(k) 4.00Sq.mm 4 core round PVC sheathed Rupees One Hundred
359 201.00 Mtr. 176.75 Seventy Six and Seventy Mtr.
Five Paisas Only
Providing & Erecting approved make following size of TV Co-axial flexible cable
comprising inner conductor of solid bare copper insulated with Foam PE & Secondary Rupees Thirty Nine and
360 480.00 Mtr. conductor made of poly - Aluminium film bonded Al. Braids @ suitable coverage overall
Thirty Nine Paisas Only
sheathed with black PVC insulation.(b) RG-6
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Supplying & erecting approved make Telephone Cable electrolytic copper conductor PE
insulation twisted in two pairs, & wrapped with FRLS PVC tape & sheathed with FRLS
PVC or HFFR outer Jacket suitable for telephone wiring & confirming to C-DOT erected in
existing pipe. of following size of conductors & nos.of pairs. With necessary connections. Rupees Twenty and
[A] Conductor Size 0.5 mm Twenty Paisas Only
(b) Armoured [Jelly Filled](2) Twenty Pairs Rupees One Hundred
362 188.00 Mtr. 199.98 Ninety Nine and Ninety Mtr.
Eight Paisas Only
Providing & erecting main Distribution (MDF) indoor type, back mounted frame as per Rupees One Thousand
DoT standard approved with krone strips(b) Suitable for 20 pair Three Hundred Sixty
Eight and Fifty Five
SITC of Digital / PCM / TDM EPABX System having SMT design, system with flexible
universal slots. Inbuilt Auto attendant facility, Minimum 15 Nos. conference, Analog
extension line, Calling GSM, E&M line, PRI / EI & VOIP program me through Analog
telephone digital key from Ethernet, public address cord, shall have unrestricted
simultaneous dialing facility,
QSIG protocol on PRI, 95 / STD / ISD / Local-Locking, Class of Service, Quick Dial-Single
Digit dialing of any two external number, Once only ring device, Chairman / Secretary - Do
not disturb Facility, Power Down Mode, Hot Line, Hot Outward Dialing, Day Night Mode, Rupees One Lacs Nine
Auto Call Back, Barge-in, Call Pick Up & Call Transfer, Call transfer while Ringing with 109743.57 Thousand Seven
Voice Guide System, (DISA), Caller ID (CLI), CLI Base ECF, CLI Base routing Internet Ready Hundred Forty Three and
Port, External Music Port, Call Budgeting, Call Most Calculation (ASMDR), DID Direct Fifty Seven Paisas Only
Inverse Dialing, External Music Input, Fax Homing, Global Directory Printing with
following capacities [[Approved by Competent Authority i.e. not Below the rank of
Executive Engineer ]
[D] No of Extension 64, No of Junctions 12, 8 Port IP Resource in-built, 4 Port Web base
Video Conferencing, No of expandable ports : 240, Operators Console - 01 Compatible :
ISDN and Networking
Supplying & erecting push button type telephone instrument having speaker phone Caller Rupees Five Hundred
365 62.00 Ea. ID & hands free dialing system & 30 memories with display system Single line 565.60 Sixty Five and Sixty Ea.
[[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] Paisas Only
Supplying & erecting approved make LAN cable of following size in existing pipe as per
Rupees Forty Seven and
366 9800.00 Mtr. direction. 47.47 Mtr.
Forty Seven Paisas Only
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing & erecting main Distribution (MDF) indoor type, back mounted frame as per Rupees Three Thousand
DoT standard approved with krone strips Four Hundred Forty
(d) Suitable for 100 pair Three and Nine Paisas
Providing & Erecting 6 core fibre optic SM 9/125um double sheath, CSTA, Unitube, Rupees Sixty and Sixty
Outdoor cable (per m) Paisas Only
Providing & erecting Switch board for Computer or electric apparatus consisting of
following modular type accessories mounted with PVC / Metallic concealed/open box
with single mounting base frame covered with textured/metallic /white front Rupees One Thousand
plate,modules erected with necessary connections as directed One Hundred Thirty
369 62.00 Ea. 1 no. 6A/16A universal plug-switch combined. 1133.22 Ea.
Three and Twenty Two
3 nos. 6A Switch Paisas Only
3 nos. 6A 5 pin Plug
For Modular Type Accessories. Cat. III
Supplying & erecting Approved make call bell indicator with buzzing sound and Red light Rupees One Hundred
370 10.00 Ea. indicating lamp with Red light button to attend the call suitable for 240 v 50 c/s supply to 148.47 Forty Eight and Forty Ea.
be erected. Seven Paisas Only
providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate Rupees One Hundred
371 574.00 Ea. on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. 112.11 Twelve and Eleven Paisas Ea.
confirming to IS 8828/1996 with ISI Mark Cat.III Only
Providing & erecting 240 V MCB double pole switch for motor & inductive load (C
Rupees Two Hundred
Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having
372 121.00 Ea. 299.97 Ninety Nine and Ninety Ea.
following capacity
Seven Paisas Only
(A) 6 to 32 Amp. CAT.III
(B) 40 Amp. CAT.III Rupees Three Hundred
373 10.00 Ea. 330.27 Thirty and Twenty Seven Ea.
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having
Rupees Five Hundred
10KA breaking capacity & confirms to IS :8828 in existing box having following capacity
374 31.00 Ea. 595.90 Ninety Five and Ninety Ea.
(a) 6 to 32 Amp. Cat.III
(b)40 Amp. Cat.III Rupees Six Hundred
375 35.00 Ea. 668.62 Sixty Eight and Sixty Two Ea.
(c)63 Amp. CAT.III Rupees Seven Hundred
376 42.00 Ea. 737.30 Thirty Seven and Thirty Ea.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing & erecting 415 V MCB three Pole for Motor & Inductive Load (C Curve) having
Rupees Five Hundred
10KA breaking capacity & confirms to IS:8828 in existing box having following capacity
377 35.00 Ea. 587.82 Eighty Seven and Eighty Ea.
(a) 6 to 32 Amp.
Two Paisas Only
(b)40 Amp. Rupees Six Hundred
378 2.00 Ea. 647.41 Forty Seven and Forty Ea.
One Paisas Only
(c)63 Amp. Rupees Seven Hundred
379 2.00 Ea. 716.09 Sixteen and Nine Paisas Ea.
Sheets steel powder coated enclosure suitable for incorporating One/Two nos. MCB. Rupees One Hundred
380 120.00 Ea. 176.75 Seventy Six and Seventy Ea.
Five Paisas Only
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface
mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 &
Rupees One Thousand
3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be
Four Hundred Ninety
381 2.00 Ea. used of same company of MCB to be used) suitable for 1492.78 Ea.
Two and Seventy Eight
(A) single phase incoming and horizontal single phase outgoing
(b) sheet steel double door
(B) three phase incoming and single phase horizontal type outgoing Per phase isolation Rupees Two Thousand
type (PPI) Nine Hundred Thirteen
(b) sheet steel double door and Eighty Five Paisas
Rupees Three Thousand
Four Hundred Twelve
and Seventy Nine Paisas
Rupees Three Thousand
Eight Hundred Seventy
Four and Thirty Six
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and erecting Sheet Steel powder coated Vertical MCB distribution board
(VTPN) - flush / surface mounted double door (IP54) fitted with copper insulated busbar,
Rupees Six Thousand
isolated neutral bar, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 &
Four Hundred Ninety
385 1.00 Ea. suitable for 63/100 AMP TPN MCCB + RCCB as incomer and three phase outgoing as per 6497.33 Ea.
Seven and Thirty Three
following .(The DBs should be used of same company of MCB to be used)
(B)6 way outgoing
(C)8 way outgoing Rupees Eight Thousand
386 1.00 Ea. 8402.19 Four Hundred Two and Ea.
Nineteen Paisas Only
(D)12 way outgoing Rupees Ten Thousand
Nine Hundred Sixty Five
and Fifty Seven Paisas
Providing and erecting Approved make RCCBs conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for Rupees One Thousand
388 24.00 Ea. operation on single phase 240 V,50Hz. having characteristic of quick action & tripping 1969.50 Nine Hundred Sixty Nine Ea.
with all advance feature & do not incorporate any electronic component. for following and Fifty Paisas Only
Max. rating erected as directed. (i) 25 Amps.DP Cat. III
(ii) 40Amps. DP Cat. III
Rupees Two Thousand
389 125.00 Ea. 2235.13 Two Hundred Thirty Five Ea.
and Thirteen Paisas Only
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/ aluminium die cast powder coated and high U.V. &
corrosion resistance with diffuser with company mark/name 160V to 270V, Power
Rupees Three Hundred
Factor more than 0.95, THD < 15%, CCT 3000 K to 6500K, Luminaire efficacy>
390 245.00 Ea. 85lumens/watt ,LED
373.70 Seventy Three and Ea.
Seventy Paisas Only
LED driver efficiency > 85 % ( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges shown.) (iv) 22-24 Watts, Surge -
2KV,IP-20, conventional 4 feet
Supplying and erecting led lamps with following wattage capacity of 220 to 240 voltage,
minimum 15000 burning hours life, 500 V in built-surge protection,Polycarbonate Rupees One Hundred
391 90.00 Ea. diffuser, mounting suitable for E14 / E27 / B22 lamp holders, pf >= 0.5 (A) LED Lamps 188.87 Eighty Eight and Eighty Ea.
integral type, with PC diffuser suitable LAMP holder (iii) 10 to 15 watts Cat-III Seven Paisas Only
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/aluminium pressure die cast powder coated and high
U.V. & corrosion resistance with diffuser housed in aluminium casted body with
company mark/name
160V to 270V,Power Factor more than 0.95, THD < 15 %, CCT 3000 K to 6500K,
Rupees Seven Hundred
Luminaire efficacy> 85 lumens/watt ,LED driver efficiency > 85 %( fitting required LM-79
392 880.00 Ea. 758.51 Fifty Eight and Fifty One Ea.
& LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any wattage capacity between the ranges
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for spring
loaded mounting clips complete.IP20
(iv) 22-24 watts, Surge-2 KV Cat-III
(B) LED Panel Light with provision for Plane front frame with translucent cover fixed to Rupees Two Thousand
393 475.00 Ea. housing complete.IP20 2091.71 Ninety One and Seventy Ea.
(vii) from 45 to 48 watts, 24" x 24", Surge-2 KV One Paisas Only
Supplying and erecting LED street light / Flood light fittings with High power White LEDs
wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses,
with toughened glass with company mark/name engraved or embossed 160 to
V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio Rupees Eight Thousand
394 15.00 Ea. >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings 8453.70 Four Hundred Fifty Three Ea.
required LM-79 & LM-80 certificates)(NOTE: Below description have shown ranges of and Seventy Paisas Only
Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.) (B) Flood Light (IP-65), Surge protection -4KV integral and
,Light must have 440VAC line supply with over-voltage protection. (v)above 120 to
Providing & erecting Approved make Power Saving 50 Watt Ceiling Fan with double ball Rupees One Thousand
bearing ISI mark with Condenser 230 volt A.C. 50 Hz 1200 mm sweep complete having Nine Hundred Forty Eight
395 533.00 Ea. 3blades with aluminium blades with , canopy & 30 cm. down rod erected with 1948.29 Ea.
and Twenty Nine Paisas
earthing.(Make shall be approved by Engineer in charge)) Only
Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod Rupees One Hundred
396 533.00 Mtr. erected duly painted for fan complete with proper insulation without leakage and 108.07 Eight and Seven Paisas Mtr.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Supplying & erecting fan hook box of 10 mm M.S. round bar bounded to the RCC bars up Rupees One Hundred
397 533.00 Ea. to 50mm length each side and pierced through a 16 Gauge M.S. box / Heavy Duty PVC box 108.07 Eight and Seven Paisas Ea.
complete erected concealed in Ceiling with necessary finishing. Only
Supplying & erecting approved make low noise decorative exhaust fan having square Rupees One Thousand
frame ABS body with inbuilt lowers & square frame. 200mm with 1350RPM Cat.II Cat.II Seven Hundred Three
and Eighty Seven Paisas
Supplying & erecting single phase approved make industrial exhaust fan suitable for
Rupees Two Thousand
medium duty ring mounted low noise operation suitable for medium duty having
399 10.00 Ea. following dia size and maximum speed in RPM 2054.34 Fifty Four and Thirty Ea.
Four Paisas Only
[A] 305 mm dia 900 RPM Cat.III
Supplying and erecting approved make double ball bearing oscillating type Heavy duty Rupees Six Thousand
bracket fan with Aluminium Blades A.C. 23OV. 50cy/s wall mounted with height Four Hundred Thirty
400 10.00 Ea. adjustment and rotary tilting device complete with guard, wall bracket,mounting 6438.75 Ea.
Eight and Seventy Five
accessories as directed.(B) 600mm Paisas Only
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium
Rupees Two Hundred
conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench /
401 517.50 Mtr. 284.82 Eighty Four and Eighty Mtr.
pipe of following size of cables. (C) 3 1/2 core 50 Sq. mm ( 25 Sq.1/2 mm core)
Two Paisas Only
(D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 core) Rupees Three Hundred
402 360.00 Mtr. 372.69 Seventy Two and Sixty Mtr.
Nine Paisas Only
(E) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2 core) Rupees Four Hundred
403 100.00 Mtr. 484.80 Eighty Four and Eighty Mtr.
(F) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 core) Rupees Five Hundred
404 180.00 Mtr. 540.35 Forty and Thirty Five Mtr.
(G) 3 1/2 core 150 Sq. mm ( 70 Sq. mm 1/2 core) Rupees Seven Hundred
405 532.50 Mtr. 731.24 Thirty One and Twenty Mtr.
Four Paisas Only
(I) 3 1/2 core 240 Sq. mm( 120 Sq. mm 1/2 core) Rupees Nine Hundred
406 930.00 Mtr. 904.96 Four and Ninety Six Mtr.
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand / Solid
Rupees One Hundred
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing
407 2530.00 Mtr. 140.39 Forty and Thirty Nine Mtr.
trench / pipe of following size of cables.
(C) 4 core 10 Sq. mm
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
(B) 4 core 6 Sq. mm Rupees One Hundred
408 500.00 Mtr. 126.25 Twenty Six and Twenty Mtr.
Five Paisas Only
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium
Rupees One Hundred
conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench /
409 2100.00 Mtr. 153.52 Fifty Three and Fifty Two Mtr.
pipe of following size of cables.
(A) 4 core 16 Sq. mm
(B) 4 core 25 Sq. mm Rupees One Hundred
410 2550.00 Mtr. 190.89 Ninety and Eighty Nine Mtr.
Making trench in soft soil of suitable width of 90 cm deep for laying cable or locating the
Rupees Fifty Five and
411 95.00 Mtr. fault all over the run and back filling the same and making the surface as normal ground. 55.55 Mtr.
Fifty Five Paisas Only
Making trench in Hard Murrum / Tar Road of suitable width of 90 cm or required depth Rupees Seventy Four
412 50.00 Mtr. for laying any size of cable or locating the fault all over the run and back filling the same 74.74 and Seventy Four Paisas Mtr.
and making the surface as normal ground. Only
(B) If additional machinery like hammer driller or JCB use [Add] Rupees Three Hundred
413 50.00 Mtr. 357.54 Fifty Seven and Fifty Four Mtr.
Providing and erecting iron clad cable route marker duly marked with ELE.CABLE of size Rupees Two Hundred
414 30.00 Ea. 23 cm.X 12 cm. Flushed with ground in cement foundation as directed by Engineer in 240.38 Forty and Thirty Eight Ea.
charge. Paisas Only
Covering of cable with second class bricks or cement tiles laid cover the cable crosswise & Rupees One Hundred
415 90.00 Mtr. also on both sides with covering of 7. 5 Cm. layer of sand above & below cable (16 bricks 140.39 Forty and Thirty Nine Mtr.
per meter) Paisas Only
Supplying following size of Light duty “A” Class G.I . Pipe & erecting as directed by Rupees One Hundred
416 30.00 Mtr. Engineer-in-charge. (A) 25 mm dia 172.71 Seventy Two and Seventy Mtr.
One Paisas Only
Providing & laying approved make Double walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same Rupees Ninety Five and
417 50.00 Mtr. material at required depth in existing trench for laying of cable. below ground / road 95.95 Mtr.
Ninety Five Paisas Only
surface for enclosing cable (C))90 mm outer dia
(D)120 mm outer dia. Rupees One Hundred
418 100.00 Mtr. 137.36 Thirty Seven and Thirty Mtr.
Six Paisas Only
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and, fixing heavy duty flange type brass double compression type cable gland
with rubber ring for PVC insulated armoured cable complete with out going tails, Rupees Seventy Five and
419 8.00 Ea. insulating tape etc for following size of cables. 75.75 Ea.
Seventy Five Paisas Only
(B) 3 & 1/2 core 35/50 Sq. mm
(C) 3 & 1/2 core 70 Sq. mm Rupees One Hundred
420 6.00 Ea. 103.02 Three and Two Paisas Ea.
(D) 3 & 1/2 core 95 Sq. mm Rupees One Hundred
421 2.00 Ea. 131.30 Thirty One and Thirty Ea.
(E) 3 & 1/2 core 120 Sq. mm Rupees One Hundred
422 8.00 Ea. 140.39 Forty and Thirty Nine Ea.
(F) 3 & 1/2 core 150 Sq. mm Rupees One Hundred
423 14.00 Ea. 190.89 Ninety and Eighty Nine Ea.
(H) 3 & 1/2 core 240 Sq. mm Rupees Two Hundred
424 32.00 Ea. 247.45 Forty Seven and Forty Ea.
Five Paisas Only
Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following
size evenly crimped with high pressure tool & connected to switchgear terminals with Rupees Six and Six
brass/cadmium plated nut bolts in an approved manner. Paisas Only
(B) 10 Sq.mm Rupees Thirteen and
Thirteen Paisas Only
(C) 16/25 Sq.mm. Rupees Fifteen and
Fifteen Paisas Only
(D) 35/50 Sq.mm. Rupees Twenty and
Twenty Paisas Only
Rupees Twenty Five and
Twenty Five Paisas Only
(F) 95 Sq.mm. Rupees Forty and Forty
(G) 120 Sq.mm. Rupees Forty Five and
Forty Five Paisas Only
(H) 150 Sq.mm. Rupees Sixty One and
Sixty One Paisas Only
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
(J) 240 Sq.mm. Rupees Eighty Five and
Eighty Five Paisas Only
Solder less crimping type Copper lugs conforming to IS suitable for cable of following size
Rupees Ten and Ten
434 40.00 Ea. evenly crimped with high pressure tool & connected to switchgear terminals with 10.10 Ea.
brass/cadmium plated nut bolts in an approved manner. (B) 10 Sq.mm
(C) 16 Sq.mm. Rupees Twelve and
Twelve Paisas Only
(D) 25 Sq.mm. Rupees Fifteen and
Fifteen Paisas Only
Providing and fixing approved make Perforated C type cable tray. Made from pre-
galvanized sheet steel. The cable tray should be bended as per IS 2062/1079 . with max
Rupees Three Hundred
17.5% perforation with coupler plate / Fish plate and GI hardware like nut - bolt and
437 170.00 Mtr. 322.19 Twenty Two and Mtr.
washers etc. erected on existing support as per Specification and as per instruction of
Nineteen Paisas Only
engineer in charge..
(3) 150 X 50 X 1.5 mm Thick
(5) 300 X 50 X 1.5 mm Thick Rupees Four Hundred
438 405.00 Mtr. 471.67 Seventy One and Sixty Mtr.
Seven Paisas Only
(6) 450 X 50 X 1.5 mm Thick Rupees Six Hundred
439 155.00 Mtr. 608.02 Eight and Two Paisas Mtr.
Providing and fixing approved make 'T' Junction for Perforated C type cable tray. Made
from pre galvanized sheet steel. The Junction should be bended as per IS 2062/1079.
with max 17.5% perforation with coupler plate / Fish plate and GI hardware like nut - bolt Rupees One Hundred
440 30.00 Ea. and washers etc. erected on existing support as per Specification and as per instruction of 167.66 Sixty Seven and Sixty Six Ea.
engineer in charge.. Paisas Only
A. 'T' Junction
(3) 150 X 50 X 1.6 mm Thick ' T' Junction
(5) 300 X 50 X 2.0 mm Thick ' T' Junction Rupees Two Hundred
441 90.00 Ea. 249.47 Forty Nine and Forty Ea.
Seven Paisas Only
(6) 450 X 50 X 2.0 mm Thick ' T' Junction Rupees Four Hundred
442 50.00 Ea. 459.55 Fifty Nine and Fifty Five Ea.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and fixing approved make '90° Elbow' for Perforated C type cable tray. Made
from pre galvanized sheet steel. The Junction should be bended as per IS 2062/1079.
with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on Rupees One Hundred
443 40.00 Ea. existing support as per Specification and as per instruction of engineer in charge.. 146.45 Forty Six and Forty Five Ea.
B. 90° Elbow Paisas Only
(3) 150 X 50 X 1.6 mm Thick 90° Elbow
(5) 300 X 50 X 2.0 mm Thick 90° Elbow Rupees Two Hundred
444 60.00 Ea. 219.17 Nineteen and Seventeen Ea.
(6) 450 X 50 X 2.0 mm Thick 90° Elbow Rupees Four Hundred
Providing and erecting Approved make Four pole moulded case circuit breaker having
breaking capacity ICU of 25 KA. at 415 V,having normal current rating up to 25 A to 100A. Rupees Six Thousand
with Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s. with all One Hundred Seventy
internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. Three and Twelve Paisas
ICS=100% of ICU only Cat III
Providing and erecting Approved make Four pole moulded case circuit breaker having
breaking capacity ICU of 35 KA. at 415 V. having normal current rating 125A. with Fixed
Rupees Eight Thousand
thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal
447 6.00 Ea. 8055.76 Fifty Five and Seventy Six Ea.
connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing.
ICS=100% of ICU only Cat III
Providing and erecting Approved make Four pole moulded case circuit breaker having
breaking capacity ICU of 35 KA. at 415 V. having Normal current rating 200A.with variable Rupees Sixteen
Thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal Thousand Two Hundred
connections, spreader tinned copper & complete erected in existing 16 G.M.S.housing Twenty One and Sixty
ICS=100% of ICU only Cat III One Paisas Only
Providing and erecting Approved make Four pole moulded case circuit breaker having
breaking capacity ICU of 35 KA. and above at 415 V . having normal current rating 250A.
Thousand Nine Hundred
449 3.00 Ea. with variable thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all 20946.39 Ea.
Forty Six and Thirty Nine
internal connections, spreader tinned copper & complete erected in existing 16 G.M.S.
housing. ICS=100% of ICU only Cat III
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing and erecting Approved make Four pole moulded case circuit breaker having
Rupees Twenty Five
breaking capacity ICU of 50 KA and above at 415 V having Normal current rating 400A.
Thousand Two Hundred
450 6.00 Ea. with variable Thermal & magnetic release suitable to work on A.C.supply 50 c/s. With all 25228.79 Ea.
Twenty Eight and
internal connections, spreader tinned copper & complete erected in existing 16 G.M.S.
Seventy Nine Paisas Only
housing. ICS=100% of ICU only Cat III
Providing and erecting Approved make Four pole moulded case circuit breaker having
Rupees Twenty Eight
breaking capacity ICU of 50 K.A. and above at 415 V having normal current rating up to
Thousand One Hundred
451 2.00 Ea. 630A. with variable thermal & magnetic release suitable to work on A.C.supply 50 c/s. 28173.95 Ea.
Seventy Three and Ninety
with all internal connections, spreader tinned copper & complete erected in existing
Five Paisas Only
G.M.S. housing ICS=100% of ICU only Cat III
Providing and erecting Approved make Three pole moulded case circuit breaker having
breaking capacity ICU of 25 K.A. at 415 V having normal current rating up to 25 A to Rupees Five Thousand
452 1.00 Ea. 100A. with Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s. with 5355.02 Three Hundred Fifty Five Ea.
all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. and Two Paisas Only
housing.ICS=100% of ICU only Cat III
providing and erecting Approved make standard manually operated fixed type 3 Pole Air
circuit breaker. Having 50 kA breaking capacity ,Vsr=690 v, Ui=1kv ,impulse voltage=12 Rupees Forty One
kv with ICU=ICS=ICW (1 sec), with following type of relay and accessories Thousand Six Hundred
.(1) Equipped with DN-1 magneto thermal release, CTs & 6NO + 6NC auxiliary contacts & Seven and Ninety Six
secondary isolating contacts of following current ratings. (b) 630Amp Cat III Paisas Only
Providing & erecting additional parts for Air Circuit Breakers as follows: (A) Auxiliary Rupees One Thousand
454 1.00 Ea. Contact Block for CN-CS 800 to 2500 & 2 NO + 2 NC 1670.54 Six Hundred Seventy and Ea.
Fifty Four Paisas Only
(G) Shunt Release Type EA:24/48 V, 110V, 220V DC Rupees Two Thousand
455 1.00 Ea. 2055.35 Fifty Five and Thirty Five Ea.
(J) Earth Fault Release Type EF 1 (10%, 20% ) Rupees Two Thousand
One Hundred Fourteen
and Ninety Four Paisas
(M) CTs for 800 C / 1000 C with 400A / 640A and 800A taps for Fixed & Drawout Type Rupees Two Thousand
ACBs Seven Hundred Eighty
Two and Fifty Five Paisas
Providing and erecting following additional parts for panel mounting MCCBs Rupees Eight Hundred
458 24.00 Ea. (A)Extended operating rotary handle with pad lock with three position trip,off,on suitable 873.65 Seventy Three and Sixty Ea.
for 25A to 250 A panel mounting cat-III Five Paisas Only
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
(B)Extended operating rotary handle with pad lock with three position trip,off,on suitable Rupees One Thousand
459 3.00 Ea. for 400A to 630 A panel mounting cat-III 1310.98 Three Hundred Ten and Ea.
Ninety Eight Paisas Only
Supplying and erecting triple pole & neutral 440V/ 500V panel mounting Aluminium
Busbars with four equal Nos. of bus having current density not more than 0.8 Amp. /
sq.mm (Rated current / cross section area) duly wrapped with colour insulating tape for Rupees One Thousand
460 12.00 Mtr. phase sequence of following current carrying capacity, erected with necessary bus bar 1037.27 Thirty Seven and Twenty Mtr.
supports /insulators, main cable socket to each busbar,erected in existing cubical panel Seven Paisas Only
with necessary connections.
(B) Suitable for 200 Amp. Capacity
(C) Suitable for 300 Amp. Capacity
Rupees One Thousand
461 45.00 Mtr. 1469.55 Four Hundred Sixty Nine Mtr.
and Fifty Five Paisas Only
(D) Suitable for 400 Amp. Capacity
Rupees Two Thousand
462 35.00 Mtr. 2204.83 Two Hundred Four and Mtr.
Eighty Three Paisas Only
(E) Suitable for 630 Amp. capacity Rupees Three Thousand
463 50.00 Mtr. 3061.31 Sixty One and Thirty One Mtr.
(F) Suitable for 800 Amp. capacity
Rupees Six Thousand
464 30.00 Mtr. 6240.79 Two Hundred Forty and Mtr.
Seventy Nine Paisas Only
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing & erecting weather proof, dust & vermin proof, floor mounted front operated
indoor type cubical panel board necessary IP-42 and above protection as per approval
from engineer incharge made from 14 SWG thick CRC M.S. sheet for outer body & doors,
16 SWG thick CRC M.S.sheet for internal partitions with necessary accesories , supporting
angles/ flats channel including cutting, bending, drilling, welding, riveting with internal
partitions & cable alley as per requirements & instruction of engineer-in-charge with
erection of supplied switch gears, BUSBARS, suitable size of inter connecting PVC copper
wire / copper-aluminium strips, rubber grommets, rib, bakelite control fuses/MCB for Rupees Fourteen
Thousand Nine Hundred
465 50.00 Sq.Mtr measuring instruments, earth bus & earth bolts, foundation flange - bolts-base Plates, 14902.55 Sq.Mtr
sufficient nos. of hinged doors, handles with locking arrangement and rubber Two and Fifty Five Paisas
gasket,heavy duty end terminal connection,danger notice board,necessary Only
ventilation,earthing strip complete. The Panel shall be painted with epoxy powder
coating. (The rates excludes the cost of switchgears, bus bars, inter connecting mains &
Copper Aluminium strips, meters, Fuses etc. The dimension shall be measured excluding
base beams) The panel shall be supplied with following approved manufacturers with
following size. (B) The standard companies switch gear shall be used and only
manufacturers at CPRI approved factory. (i) with 350mm depth.
(ii) With 550 mm. Depth Rupees Nineteen
466 100.00 Sq.Mtr 19387.96 Hundred Eighty Seven Sq.Mtr
and Ninety Six Paisas
(iv) with 1000 mm. depth Rupees Forty Thousand
Nine Hundred Ninety
467 50.00 Sq.Mtr 40999.94 Sq.Mtr
Nine and Ninety Four
Providing and erecting multifunctional meter suitable for application of Power
monitoring and showing measurement of following Voltage, Frequency, Apparent energy,
Apparent power, Active and reactive energy, Active and reactive power, Average voltage
Vavg, Peak demand power PM, QM, SM, Demand power P, Q, S, Apparent power S, S1, S2,
S3, Unbalance current, Power factor and displacement PF (signed, four quadrant), Rupees Fourteen
Calculated neutral current, Active, reactive, apparent energy (signed, four quadrant), Thousand One Hundred
Active power P, P1, P2, P3, Voltage U21, U32, U13, V1, V2, V3, Phase currents, Average Twenty Three and Eighty
current Iag, Peak demand currents, Reactive power Q, Q1, Q2, Q3, Demand current I1, I2, Four Paisas Only
I3, [Us] rated supply voltage 40...300 V AC 45...65 Hz, 40...300 V DC, Network frequency
Hz, Type of network 3P, Display type 7 segments LED, Display colour Red, Messages
display capacity 3 fields of 4 characters, Display digits 12 digit(s) - 14.2 mm in height
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing & erecting L.T. Current Transformer with bar primary 50/5 to 1000/5 ratio
Rupees Two Hundred
VA burden erected in existing CRCA box duly secured with insulating materials connected
469 21.00 Ea. 274.72 Seventy Four and Ea.
Seventy Two Paisas Only
Supplying and erecting approved make suitable panel indicator LED type lamp, lens cover, Rupees Forty Three and
complete erected with necessary connections. Forty Three Paisas Only
Design, Supplying, installing, testing of factory fabricated ready made Three phase APFC
Panel Cubical Panel fabrication should be type tested as per IEC 61921, 61439:1&2
Capacitor Duty Contactor for switching as per following Steps Incomer Switch of MCCB
type Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault protection Incomer
Switch of MCCB type Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault
protection,Copper tinned insulated Busbar,Cubical panel should be indoor type with IP 43 Rupees Four Lacs Thirty
and IK 10,Metalized polypropylene film tye3-phase 550Volt Capacitor,De tuning Reactor Three Thousand One
471 1.00 Ea. for each capacitor,Panel having Short Circuit and Overload protection,Each step Capacitor
Hundred Three and
having suitable MCB with Sc, OL, internal earth fault relay,Each stage having Stage Fifteen Paisas Only
Contactor (Capacitor load rating),PF regulator master controller having suitable steps
with LCD display, Rs 485 Communication port, Indication LED Lamps for main incomer
and ON-OFF for each capacitor bank,MS Chanel for Floor mounting, Cable entry as per site
situation,Cooling fans for panel.
Providing and fixing printed instruction chart both in English and Gujarati and duly Rupees One Hundred
472 10.00 Ea. framed with front glasses, for treatment of person suffering from Electric shock with 130.29 Thirty and Twenty Nine Ea.
minimum 50" diagonally size. Paisas Only
Providing pair of rubber hand gloves suitable for working on 11 KV/22 KV supply. Rupees Two Hundred
473 2.00 Ea. 214.12 Fourteen and Twelve Ea.
Supplying rubber matting of following thickness as per IS:15652/IEC 61111 Rupees One Thousand
474 30.00 Sq.Mtr (b)4mm 1027.17 Twenty Seven and Sq.Mtr
Seventeen Paisas Only
Providing and erecting metallic vitrified danger notice board as per language suggested
Rupees Sixty Nine and
475 7.00 Ea. by engineer incharge for MEDIUM VOLTAGE installation to be erected as per IS-2551. 69.69 Ea.
Sixty Nine Paisas Only
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Supplying & erecting in earthpit of minimum bore dia. 225mm size approved make Safe
Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of
corrosion free hot dipped G.I.Pipes having Outer pipe dia of 80 mm having 80-200
Micron galvanising, Inner pipe dia of 40 mm having 200-250 Micron galvanising,
connection terminal dia of 14 mm with constant ohmic value surrounded by highly
conductive compound with high charge dissipation suitable for following type of
applications with chamber and heavy duty cover (A)(approved make OEM has to submit Rupees Five Thousand
test certificate including value of earth resistance of installation duly stamped and signed Eight Hundred Forty Two
476 28.00 Ea. by agency and officer Incharge has to ensure the value of earthing resistane mentioned in 5842.85 Ea.
and Eighty Five Paisas
test Certificate) & having back filling compound of (B) Inner chemical (CCM Compound)- Only
Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no
load & dry form, Sulphar content:- <2%(C) Back fill Compound :- Earthing compound
should be capable to retain moisture for long time Necessary test report must be
submitted by Agency [A] For electrical installation up to 440 V
Length of Pipe - 1 Mtr
Back filling compound - 1 Nos. of Bag of 15 Kgs.
[B] For Electrical installation up to 11 KV located in other than normal soil i.e. Soft
Rupees Seven Thousand
Rock, Marshy Soil etc.
477 6.00 Ea. 7095.25 Ninety Five and Twenty Ea.
-Length of Pipe : 2 mtr
Five Paisas Only
-Back filling Compound :1 no. Bag of 25 Kg.
Providing and erecting required size HOT deep Galvanised iron strip for earthing of H.T. , Rupees Seventy Seven
478 100.00 Kg. OCB/ ACB/ Transformer LT panel board, Motors etc. using proper clamp. 77.77 and Seventy Seven Paisas Kg.
Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG. Rupees Seventy Seven
479 100.00 Kg. 77.77 and Seventy Seven Paisas Kg.
Providing, erecting, testing & commissioning approved make oil immersed ONAN cooled,
double wound, core type indoor / outdoor copper wound 11KV/ 433V step down
transformer of following capacities operating on 3 phase, 50 Hz 4 wire & neutral earthed
480 system continuously rated for a full temperature rise in oil not exceeding 45 Deg.C.at
maximum ambient temp. of 50 Deg. C. complete with necessary radiator first filling of new
transformer oil & standard fitting as below complying with IS 1180( Part 1 ):2014
standards with energy efficiency level
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Off load tap changing range steps +2.5% to -5% on H.V for variation should be provided.
The H.V. shall be connected Delta & Secondary with star connection. The transformer
should have cable-end boxes on H.T. side suitable for up to 3 core 150 sq.mm. XLPE cable
& on L.T. side suitable for bus duct or cables as per requirement complete with test
certificates from manufacturers
1. Oil conservator with filling Hole & Cap - One No.
2. Thermometer pocket with 6" dial type thermometer switch alarm & trip
contacts- Two nos.
3. Silica-gel breather with charge- One No.
4. Plain oil level gauge - One No.
5. Drain / Sampling / Filter valve- One No.
6. Top Filter Valve - One No.
7. Explosion vent with Diaphragm - One No.
8. Rating & Diagram plate - One No.
9. Additional neutral bushing for earthing - One No.
10. Bi directional Roller - Four Nos.
11. Earthing terminals - Two Nos.
12. Lifting lugs - Two Nos.
13. Air release plug. - One No.
14. Double float buchholz relay with Alarm and trip contacts.
15. Control cable as required from Transformer to VCB Panel is to be provided with
necessary connection to VCB relays for protection.
as per IS 1180 level-1
(b)315 KVA Rupees Seven Lacs
Max. allowable loses at 50 % of rated load is 1.025 KW and at full load is 3.1 KW Cat.III Ninety Seven Thousand
Four Hundred Eleven and
Sixteen Paisas Only
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing, erecting, testing commissioning & getting Plan Approval as well as NOC from
Electrical Inspector for extensible H.T panel comprising of one 630A/800A/1250A. H.T.
VCB incoming & Two outgoing 630/800/1250 A Drawout type VCB confirming as per I.S.
for use on 11 KV, 3 phase, 50 c/s. unearthed A.C. supply system having breaking rupturing
capacity of 350 MVA or Above complete with spring operated mechanism, mechanically &
automatic ON-OFF and spring mechanism charged, discharged indicators, ON-OFF Rupees Thirteen Lacs
mechanical push button, operation counter necessary auxiliary switches, closing shunt 1328836.80 Twenty Eight Thousand
trip, air insulated busbar chamber having heat shrinkable PVC sleeves, mechanical Eight Hundred Thirty Six
interlocks safety shutters, isolating plugs and a VCB trolley with three vacuum and Eighty Paisas Only
interrupters with epoxy support insulators and self aligning finger type isolating contacts.
The breaker shall be Manual cum motorised mechanism & auto spring charge with TNC
switch closing with following accessories. The Standared Companies Switchgear shall be
Used and Only Manufacutres as per IEC 61439 for beneficial use.
1.flush mounting type digital multifunctional meter with communication facility - Three
2. Power Factor Meter One No
3. Double core current transformer cast resin type having ratio 200 to 50/1 core for
metering & second core for protection having required class of accuracy. - Three Sets
4. Instantaneous under voltage relay,Over Voltage relay & Temperature rise Tripping
5. Electrical closing coil & short trip coil operating on 110V. D.C.- Three Sets
6. Auxiliary relay for anti pumping device
7. Three phase Three limb Drawout type feeder connected & output of 200 VA cast resin
insulated potential transformer having ratio 12000V./110V. and 200 VA Burdon with
accuracy. - One No.
8. Common Alarm bell operating on 110V A.C.- One No.
9. Digital KWH Meter - One No.
10. Cable boxes suitable up to 11 KV 3core 150 sq.mm XLPE cable. - Three Nos.
11. 230V. A.C. to 110V. D.C. power pack for closing & tripping circuit common.
12.Breaker ON-OFF, Auto trip and spring charged indicators. - Three Sets.
13.Phase indicating & panel illumination lamps with plug socket - Three Sets.
14.Numerical Communicable type non directional O/C & E/F Relay with
a setting of 5-250% both in O/C & E/F. -Three Set
complete with necessary interconnection with air insulated high grade copper busbar
{Breaker Testing scope include Closing Time, Opening Time, VCB Hi-Pot test at Site}{
Relay Testing Scope Include testing of all protection by three phase testing kit at site
}(VCB Trolley is to be provided)
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Providing, and erecting 11 KV D.P. 9 mtr. high Structure made of 6" x 3" ‘I’‐Section
Rupees Ninety Eight
Girder, 4" x 2"channels, clamps, nuts, bolts etc. Suitable for erection of the followings duly
Thousand Four Hundred
482 1.00 Ea. connected with necessary ACSR conductors. as per drawing approved by the Engineer- in 98433.59 Ea.
Thirty Three and Fifty
charge complete with following. Height as per IS 7 Mtr above ground )
Nine Paisas Only
(A) 11 KV 200 Amps Drop out fuses with S.R.B.P. tubes carries.-Three nos
(B) 11 KV G.O.D. switch complete with insulators, operating handle with galvanised pipe,
Sq.bar etc. 400 Amp.- One Set
(C) 11 KV lightening arrestor with clamp- Three Nos.
(D) 11 KV shackle insulators- Six Nos.
(E) The above D.P. structure should be earthed with 25 mm.X 3 mm thick double copper
earth strips run separately and connected with separate copper plate earth electrode.
Supplying and erecting, commissioning and testing of Diesel Generating set confirming to
IS: 4722:1968 & BS:5514 having continuous rating, 3 phase, 415 volts, 50 cycles A.C.
supply comprising of a totally enclosed air/water cooled diesel engine with multi-
cylinders developing suitable BHP not less than following capacity at 1500 RPM with
10% overload for one hour in 24 hours with standard accessories like fly wheel,
lubricating oil cooler, "A" class governor, heavy duty fuel wheel and lubricating oil filter,
483 oil bath air filler, lubricating oil pressure gauge, end exhaust manifold, standard set of
tools with adjustable spanners, screw drivers, cylinder head to cover, joint cylinder head
to exhaust, element lube oil filter, 12 / 24 volts electric starting equipment complete with
standard heavy duty battery, dynamo, cut-outs, ammeter, necessary wiring, pressure
gauge, starter etc and heavy duty Residential type exhaust silencer (With DEF System)
and vertical hot air duct both
logged with asbestos rope, save oil trays, exhaust piping of required length, standard
wall/floor mounted fuel with level indicator and piping and drip proof alternator, self
excited, self regulated, screen protected, with excitation system, capable of delivering the
rated system output at 415 volts, 3 phase, 0.8 PF, 50 Hz, 4 wire, running at 1500 RPM,
conforming to IS-4722- 1968 with voltage regulation +/- 5% of rated voltage from no
load to full load. Both the engine and alternator fitted on a common fabricated steel base
plate with antivibration mounting engine and alternator both connected to each other
by flexible flange coupling and with floor/wall mounted control panel box comprising of
voltmeter ammeter, selector switches, ACB / MCCB / MCB of adequate capacity,
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
indicator lamps duly wired with HRC fuses. The alternator & control panel shall be
connected with provided suitable capacity armoured cable and complete with Acoustic
enclosure (canopy) made out of 16 SWG CRCA Sheet, sound absorbing material Rockwool
of 64 density & 100 mm thick conforming to IS:8183 / PU Foam of 40 Density - at least
mm. The resin bonded rockwool covered from inside the canopy by perforated sheet with
3/4 mm holes, sound level not more than 75 dB at a distance of 1 mtr, as per PVCT
norms.DG set should have in built fuel tank capacity of minimum 8 hrs of continous
running capacity on full load . Erection, commissioning and satisfactory testing as per
requirement with first filling of fuel (minimum up to the 80% of fuel tank capacity), oil,
etc. with guarantee / Warrantee of complete system for Two years. & with obtaining all
necessary certificate from Electrical Inspector. The Capacity and Ratings of DG sets are as
below. (As per new CPCB4+ Emission norms Engine With - Turbo Charger, EGR (Exhaust
Gas Recirculation), CRS (Common Rail Fuel System), DOC (Diesel Oxidation Catalyst), SCR
(Selective Catalytic Reduction), Integrated wiring harness connected to ECU)
(R) Continuous rating of 250 KVA ,BHP not less than 309 BHP Rupees Nineteen Lacs
Sixty Nine Thousand
1.00 Ea. 1969798.96 Seven Hundred Ninety Ea.
Eight and Ninety Six
Providing & erecting approved make ATS panel suitable for following size of 3 phase,
V., 50 cycles, A.C. diesel generating set complete of scope as detailed below: Rupees Ninety One
1) Power module: Motorised Changeover switch with ATS controller, Auxiliary contactor Thousand Five Hundred
484 1.00 Ea. with NO & NC contacts with Automatic Battery Charger, indicating lamps for Generator 91585.79 Ea.
Eighty Five and Seventy
ON, Mains ON, Load and suitable control terminals and power terminals with neutral Nine Paisas Only
earthing studs. (G) ATS Panel for 180 / 250 KVA 3 phase DG Set
Providing and erecting ISI Marked 3 core 95 Sq.mm XLPE insulated 11 KV armoured Rupees One Thousand
cable Aluminium conductor IS-7098 to be laid on wall with clamps or in provided cable Three Hundred Seventy
trench / pipe approved manner as directed. and Fifty Seven Paisas
Providing and erecting cable end termination kit, heat shrinkable Push on type Densons/ Rupees Fourteen
Raychem/ Elastimold make suitable for 11 KV XLPE cable 3core 95 & 120 Sq.mm Thousand Six Hundred
(A) Outdoor type Eleven and Sixty Seven
(B) Indoor type Rupees Eight Thousand
487 2.00 Ea. 8004.25 Four and Twenty Five Ea.
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Supplying and erecting horizontal / vertical mounting type storage water heater with
copper container housed in M.S./S.S./ABS body insulated with glass wool/puff complete Rupees Seven Thousand
488 8.00 Ea. with heating elements,adjustable thermostats 300C to 850C, indicating lamp, safety valve, 7808.31 Eight Hundred Eight and Ea.
fusible plug, etc.complete erected with coach bolts, nuts. washers & cementation (B)15 Thirty One Paisas Only
Ltr-.with 2 /3K.W. heating element Cat.III
Providing & erecting water cooler having storage capacity 150 Ltr. & cooling capacity
Ltr.per hour @ an ambient temp of 45˚ C. The outlet temp. of the water should drop by Rupees Fifty Five
15˚C within a hour, The water cooler should be comprising of hermetically sealed Thousand Eight Hundred
489 10.00 Ea. compressor, fan motor, condensing unit, water tank surrounded by evaporating, coil,
Ninety Three and Forty
thermostats, relay etc.complete with necessary inlet & outlet connection. The body of Paisas Only
water cooler will be made from Stainless Steel.
Supplying and erecting water filter cum purifier with ultra violate technology. (Aquaguard Rupees Five Thousand
/ waterdoc model or equivalent symphony/ crystal/videocon model) Four Hundred Twenty
Four and Seventy One
Supplying & erecting approved make motor control cubical panel (Direct - on - line)
made from 16 G. CRCA sheet duly epoxy powder painted inside and outside with hinged
doors and locking, arrangement consisting of suitable size of ON- OFF isolator (AC -
Rupees Seven Thousand
3/23duty) main fuses, single phasing preventer, indicating lamps for R- Y - B phases,
Seven Hundred Twenty
491 2.00 Ea. overload relay, Automatic water level controller, Ammeter, Voltmeter each with two way 7722.46 Ea.
Two and Forty Six Paisas
selector switch incoming, wires duly socket crimped, main contactor & overload relay,
start - stop push buttons, to be erected on angle iron frame grouted on wall as directed.
The isolator, overload relay & contactors will be of L & T, Siemens or BCH make only. (A)
DOL up to 5.0 H.P.
Providing & erecting open well horizontal mono block pump set with cast iron body, Rupees Fifteen
complete for three phase submersible motor having[C] For 3 HP 3 phase open well Thousand Seven
492 2.00 Ea. horizontal mono block pump set suitable for 85 LPM to 270 LPM @ 11 mtr to 33 mtr head 15707.52 Ea.
Hundred Seven and Fifty
suitable for 50/65 mm dia delivery pipe Cat.II Two Paisas Only
Providing and erecting ISI marked PVC insulated PVC Sheathed Flat flexible Submersible Rupees One Hundred
493 120.00 Mtr. copper cable approved make of following Size. (C) 3 Core x 4 Sq. mm 146.45 Forty Six and Forty Five Mtr.
Supply of Fibreglass Platform Step (A Type) Ladder - 15 FT having following
specifications : Rupees Thirty One
It should have large fully serrated Thousand Six Hundred
494 2.00 Ea. platform 15” wide 20” deep which locks ladder , Aluminium feet with thick rubber tread, 31636.23 Ea.
Thirty Six and Twenty
top rail guard to serve as a railing, two pairs of gusset support at the bottom step and All Three Paisas Only
gussets are heavy duty steel. Capacity : 300 lbs
Item Quantities estimated Items Description Estimated Rates Unit Total amount
Item Quantities estimated Items Description Estimated Rates Unit Total amount
No. but may be more or In Figures In Words According to
Supplying and erecting approved make online Un-interruptible Power Supply system
comprising flat cum-boost charger with IGBT base rectifier & Inverter & sealed
maintenance free SMF batteries. The charger having operating capacity for input 160- Rupees Two Lacs
270V AC & inverter having output 230V,50 Hz Ac with 0.8 load power factor with Seventy Thousand Nine
495 12.00 Ea. battery, over/under voltage output with over load & short circuit protection equipment. 270989.06 Ea.
Hundred Eighty Nine and
The system housed in CRC sheet duly powder coated paint with following power Six Paisas Only
backup.with MS painted batteries stand, 10% Overload capacity for momentary load. (I)
10 KVA 3 - phase with 1Hr Backup
Providing and erecting Inverter based approved make split air-conditioning unit
consisting of condensing unit with variable speed fan motor, inverter type hermetically
sealed rotary compressor with accessories etc. duly connected separately erected Rupees Forty One
evaporating unit and blower motor with its accessories by means of extra supplied Thousand Seven
proper insulated copper tubing,drain PVC pipes suitable for ( cost includes Eco Friendly Hundred Twenty Five
green gas charging and 15A plug top & Remote Control & MS Stand) with necessary core and Twelve Paisas Only
cutting. (1) For ISEER Range (KWH/KWH)(3.1 to 3.99) (B) for 1.5 ton capacity
(C) for 1.7 to 2 ton capacity Rupees Fifty One
Thousand Six Hundred
Sixty Six and Fifty Five
PA System :- Supplying & erecting Amplifier having following specification:
Power Output :250W (RMS) (300W Max.)
inputs : 6 Misc. & 2 Aux.
frequency Response :50-1500HZ I3db Rupees Eleven Thousand
Tone Controls : Cut & Boost type Two Hundred Ninety
498 7.00 Ea. LED Meter : 5 LED Arrays
Eight and Eighty Seven
The amplifier suitable to operate 240V A.C.& 24volt D.C. (Battery) with automatic Paisas Only
changeover from AC to Battery operation, duly protected by wrong Battery Polarity
connections. [[Approved by Competent Authority i.e. not Below the rank of Executive
Supplying & erecting recess wall mounting speaker with 5W rated input power 3.3 K.
Ohms / 3W impedance, 100 - 10000 Hz frequency response with 6 inch dia. cone type
ohms speakers duly fitted in ABS plastic cabinet of colour match with wall or ceiling of Rupees Four Hundred
499 200.00 Ea. following size. [[Approved by Competent Authority i.e. not Below the rank of Executive 402.99 Two and Ninety Nine Ea.
Engineer ] Paisas Only
(a)Round Shaped, 230mm dia. Speaker
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
01 Civil Building Specification Book.pdf
02 Electrical Specification Book.pdf
03 Circular Part 1.pdf
04 Circular Part 2.pdf
05 Special Condition and formats.pdf
06-01 Civil Make List 2025 (1).pdf
06-02 Special Instruction to Bidder.pdf
07 SBD-SDH Savli.pdf
08 SCHEDULE B SDH SAVLI.pdf
09 Specification SDH Savli.pdf
10 Savli SDH Drg.pdf
11 Tender Document 166-02.pdf
Download all tender documents and submit your bid