| Sl No | Description | Qty | Unit | SUNEHARI BAGH BUILDERS PVT. LTD. L2 | MCC POWER PROJECTS PVT. LTD. L1 |
|---|---|---|---|---|---|
| 1.00 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas including getting out and disposal of excavated earth at approved dumping sitel by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. dumping site/disposel site shall be arranged by the contractor at own cost and nothing shall be paid extra.All kinds of soil | 9,394.73 | Per Cubic Meter | 200 ₹18.8 L | 189 ₹17.8 L |
| 2.00 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas including getting out and disposal of excavated earth at approved dumping sitel by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. dumping site/disposel site shall be arranged by the contractor at own cost and nothing shall be paid extra.Ordinary Rock | 3,707.71 | Per Cubic Meter | 300 ₹11.1 L | 319 ₹11.8 L |
| 3.00 | Excavation work by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains in earth work in all heights with chiselling and wedging out of rock (where blasting is prohibited) and their intermediate classification of soils including, dewatering wherever required, Per Setting out to required lines. levels as show on the drawings and as directed by the Engineer In charge at site and sorting out useful and un-useful material and transportation of the un-useful material for disposing at approved dumping site otherwise and including payment of prescribed charge of dumping to the owner of dumping site (to be arranged by the contractor) for the satisfaction of Engineer-in Charge through all modes of transportation including head load, animal load or mechanical means along with its leveling fine dressing and with all kinds of labour, machineries, tools, equipments and safety measure and other incidentals necessary to complete the work by mechanical means and labour (if required).All kinds of soil | 4,100.02 | Per Cubic Meter | 250 ₹10.3 L | 232 ₹9.5 L |
| 4.00 | Excavation work by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains in earth work in all heights with chiselling and wedging out of rock (where blasting is prohibited) and their intermediate classification of soils including, dewatering wherever required, Per Setting out to required lines. levels as show on the drawings and as directed by the Engineer In charge at site and sorting out useful and un-useful material and transportation of the un-useful material for disposing at approved dumping site otherwise and including payment of prescribed charge of dumping to the owner of dumping site (to be arranged by the contractor) for the satisfaction of Engineer-in Charge through all modes of transportation including head load, animal load or mechanical means along with its leveling fine dressing and with all kinds of labour, machineries, tools, equipments and safety measure and other incidentals necessary to complete the work by mechanical means and labour (if required)Ordinary Rock | 1,275.15 | Per Cubic Meter | 400 ₹5.1 L | 425 ₹5.4 L |
| 5.00 | Stone /Boulder filling under floor dry hand packed including carriage of material upto all leads and lifts and as per direction of Engineer-in- Charge. | 1,491.21 | Per Cubic Meter | 2,400 ₹35.8 L | 1,200 ₹17.9 L |
| 6.00 | Providing and laying brick bat filling in foundation and plinth including carriage of material upto all leads and lifts and as per direction of Engineer-in- Charge. | 14.91 | Per Cubic Meter | 3,000 ₹44,730 | 2,600 ₹38,766 |
| 7.00 | Filling available excavated earth in all kind of soils ,in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, including carriage of material in all leads and lifts as per the direction of Engineer-in- Charge. | 2,708.58 | Per Cubic Meter | 150 ₹4.1 L | 170 ₹4.6 L |
| 8.00 | Supplying and filling in plinth with river sand under floors, including watering, ramming, consolidating and dressing complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer-in- Charge. | 10.06 | Per Cubic Meter | 2,500 ₹25,150 | 3,500 ₹35,210 |
| 9.00 | Surface dressing of the ground including removing vegetation and in-equalities and disposal of rubbish materials including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer-in- Charge. | 1,800 | Per Square Meter | 20 ₹36,000 | 35 ₹63,000 |
| 10.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand) : 3 graded stone aggregate 20 mm nominal size) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer-in- Charge. | 862.9 | Per Cubic Meter | 8,200 ₹70.8 L | 9,250 ₹79.8 L |
Tender Value
₹37.8 Cr
EMD Value
₹37.8 L
Closing Date
10 Sept 2024, 5:00 pmClosed
Project Director HPTDB
Project Director Himachal Pradesh Tourism Development Board HPTDB Department of Tourism and Civil Aviation First Floor, U.S. Club Shimla 171 001, HP, India
Development of Ice Skating Rink cum Roller Skating Rink at Sakoh, Dharamshala (H.P.) (SH - Civil, WS SI, EI, Fire Fighting, Fire Alarm system and Surveillance System etc.)
2024_HPTDB_90149_1
SITDP-HP_W14/2023-24
Open Tender
Composite Works
730 days
Sakoh, Dharamshala (H.P.)
Please refer Tender documents.
9 documents required · 9 mandatory
₹5,000
Project Director HPTDB U S Club Shimla
₹37.8 L
o/o Project Director HPTDB
13 Nov 2024
8 Jul 2024
10 Sept 2024
8 Jul 2024
10 Sept 2024
3 Aug 2024
15 Jul 2024
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas including getting out and disposal of excavated earth at approved dumping sitel by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. dumping site/disposel site shall be arranged by the contractor at own cost and nothing shall be paid extra.All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas including getting out and disposal of excavated earth at approved dumping sitel by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. dumping site/disposel site shall be arranged by the contractor at own cost and nothing shall be paid extra.Ordinary Rock
Excavation work by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains in earth work in all heights with chiselling and wedging out of rock (where blasting is prohibited) and their intermediate classification of soils including, dewatering wherever required, Per Setting out to required lines. levels as show on the drawings and as directed by the Engineer In charge at site and sorting out useful and un-useful material and transportation of the un-useful material for disposing at approved dumping site otherwise and including payment of prescribed charge of dumping to the owner of dumping site (to be arranged by the contractor) for the satisfaction of Engineer-in Charge through all modes of transportation including head load, animal load or mechanical means along with its leveling fine dressing and with all kinds of labour, machineries, tools, equipments and safety measure and other incidentals necessary to complete the work by mechanical means and labour (if required).All kinds of soil
Excavation work by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains in earth work in all heights with chiselling and wedging out of rock (where blasting is prohibited) and their intermediate classification of soils including, dewatering wherever required, Per Setting out to required lines. levels as show on the drawings and as directed by the Engineer In charge at site and sorting out useful and un-useful material and transportation of the un-useful material for disposing at approved dumping site otherwise and including payment of prescribed charge of dumping to the owner of dumping site (to be arranged by the contractor) for the satisfaction of Engineer-in Charge through all modes of transportation including head load, animal load or mechanical means along with its leveling fine dressing and with all kinds of labour, machineries, tools, equipments and safety measure and other incidentals necessary to complete the work by mechanical means and labour (if required)Ordinary Rock
Stone /Boulder filling under floor dry hand packed including carriage of material upto all leads and lifts and as per direction of Engineer-in- Charge.
Providing and laying brick bat filling in foundation and plinth including carriage of material upto all leads and lifts and as per direction of Engineer-in- Charge.
Filling available excavated earth in all kind of soils ,in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, including carriage of material in all leads and lifts as per the direction of Engineer-in- Charge.
Supplying and filling in plinth with river sand under floors, including watering, ramming, consolidating and dressing complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer-in- Charge.
Surface dressing of the ground including removing vegetation and in-equalities and disposal of rubbish materials including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer-in- Charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand) : 3 graded stone aggregate 20 mm nominal size) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer-in- Charge.
Providing and laying cement concrete 1:2:4 (1 Cement : 2 Coarse sand :4 Coarse aggregate 20 mm nominal size and curing complete (All works upto plinth level) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer-in- Charge.
Providing and laying in position cement concrete 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size) of specified grade excluding the cost of centering and shuttering - All work up to plinth level : including carriage of material in all leads and lifts as per the direction of Engineer-in- Charge.
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand) : 4 graded stone aggregate 20mm nominal size). including carriage of material in all leads and lifts as per the direction of Engineer-in- Charge.
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.including carriage of material in all leads and lifts as per the direction of Engineer-in- Charge.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.including carriage of material in all leads and lifts as per the direction of Engineer-in- Charge.
Providing from work with steel plates 3.15 mm (three decimal fifteen milliPer running Metre ) thick welded with angle iron in frame 30X30X5 mm (thirty into thirty into five milliPer running Metres )so as to give a fair finish including centering , shuttering ,strutting and propping etc. with wooden battens and ballies for all heights of propping and centering below supporting floor to ceiling & removal of same for in-situ reinforced concrete and plain concrete work in including carriage of material in all leads and lifts of materials as per direction of Engineer -in -charge.
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Stairs, (excluding landings) except spiral_stairs
Edges of slabs upto 20 cm width
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete .Thermo-Mechanically Treated bars of grade Fe-500D or more..(TATA/Sail/Jindal Make or equivalent ) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 Per Kilogramme/Per cubic Metre.“Excess/ less cement used as per design mix is payable/recoverable separately). including carriage of material by mechanically & manual in all lead & lift and as per direction of Engineer incharge. (Note :- Cement content considered in this item is @ 330 Per Kilogramme/Per cubic Metre. Excess/ less cement used as per design mix is payable/recoverable separately). & rate of cement -430/bag
All works upto plinth level.
All works above plinth level upto floor V level
Providing and laying 80mm thick factory made cement concrete interlocking paver block of M -35 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. complete including carriage of material manually and mechanically in all leads and lifts as per the direction of Engineer-in-charge.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to all floor level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. (2nd class)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to all floor level. Cement mortar 1:4 (1 cement :4 coarse sand) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. (2nd class)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry including carriage of material by mechanically & manual upto all lead and lift and as per direction of Engineer-in-Charge.
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) including all cost and conveyance of materials and labour charges etc complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.
Providing Second class Deodar wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.
Providing Sal wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc. including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.
Providing and fixing Second class Deodar wood 35mm thick panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete:including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. . (Note:- Butt hinges and necessary screws shall be paid separately)
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.
Providing and fixing chromium plated brass100 mm latch handles of approved quality with necessary screws etc. complete..including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.
Providing and fixing Keyless mortice door locks on toilet doors of godrej or equivalent 100 mm with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete .including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.
Providing and fixing bright finished SS tower bolts grade-304 (barrel type) with necessary screws etc. complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge
Providing and fixing ISI marked, Stainless steel heavey duty hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. --- (a) Twin rubber stopper including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge
Providing and fiing ALUK aluminiumcurtain wall glazingsystem (SL50)with GI unit(minsulated Glass Unit) for visionpannel and spandrel panel of approved make the mullionsand transoms are squre cut and assembled using a combination of factory fitted cost face fixed junction spigots and concealed anti ratation spigos. or by transom blocks. This strong construction is easy to fabricate and allowa greater accuracy and enhanced stability . High qualityconstruction .The mullion jointing uses a speciallydesigned sleeve spigot for each mullion for a high quality joint. Cost efficiency.All machine operations can be performed on drill jigs with punch tooliing fordrainage toreduce fabrication timeand cost and achieveconsistent quality and all extruded aluminium sections towithstand wind pressure of 150kg/sqmat all height and fabricated fixed at all levels, elevation and heightsto the masonry/RCwalls withnecessary clamps , brackets and anchor fasteners , Glass will be fixed withwith pressure plate ad cap at every vertical and horizontal grooves .All clamps and brackets shall be mild steel Hot dip galvanised minium80 microns thick.The extruded aluminiumsection shall be Powder coating of minimum60 microns . Any other fastening straps , nuts, bolts, washers shall be of HILTI or Fischer make or approved eq. and of SS 304 grade.Rate shall be include to provide Fire stops at all floorlevels. EPDM gaskets, open cellpolyethylene backer rodsetc. The structural glazing sealant shall be Dow Coming and weather sealant shall be Dow Coming . All sealants shall be black in colour including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge
Door D1 made of System: Aluk 45DS ( Price i/c Profit)Door Single open , Out hinge L, Powder Coating fabrication , Glazing 1x24mm DGU (6+12+6)
Door D2 made of System: Aluk 45DS ( Price i/c Profit)Door Single open , Out hinge L, Powder Coating fabrication , Glazing 1x24mm DGU (6+12+6)
Door DW1, made of System: Aluk 45DS ( Price i/c Profit)Door Single open , Out hinge L, Powder Coating fabrication , Glazing 5x24 mm DGU (6+12+6)
Door DW2, made of System: Aluk 45DS ( Price i/c Profit)Door Single open , Out hinge L, Powder Coating fabrication , Glazing 5x24 mm DGU (6+12+6)
Door DW3, made of System: Aluk 45DS ( Price i/c Profit)Door Single open , Out hinge R, Powder Coating fabrication , Glazing 10 x24 mm DGU (6+12+6)
Door DW4 , made of System: Aluk 45DS ( Price i/c Profit)Door Single open , Out hinge L, Powder Coating fabrication , Glazing 5 x24 mm DGU (6+12+6)
DW5 , Glazing window made of System: Aluk SL50 (155 mm) ( Price i/c Profit)Door Single open , Out hinge L, Powder Coating fabrication , Glazing 52 x 34mm DGU (8+18+8)10% Jumbo 6x34mm DGU (8+18+8)
Door DW 6, made of System: Aluk 45DS ( Price i/c Profit)Door Single open , Out hinge L, Powder Coating fabrication , Glazing 5x24 mm DGU (6+12+6)
W1, Fixed Window made of System: Aluk 45DS ( Price i/c Profit)Door Single open , Out hinge L, Powder Coating fabrication , Glazing 4x24 mm DGU (6+12+6)
W2, Fixed Cum Door ,made of System: Aluk 45DS ( Price i/c Profit)Door Single open , Out hinge L, Powder Coating fabrication , Glazing 5x24 mm DGU (6+12+6)
W3, Fixed Window ,made of System: Aluk 45DS ( Price i/c Profit)Door Single open , Out hinge L, Powder Coating fabrication , Glazing 2x24 mm DGU (6 Acid +12+6)
W4, Fixed Window ,made of System: Aluk 45DS ( Price i/c Profit)Door Single open , Out hinge L, Powder Coating fabrication , Glazing 4x24 mm DGU (6+12+6)
W5/V1, Fixed Window ,made of System: Aluk 45DS ( Price i/c Profit)Door Single open , Out hinge L, Powder Coating fabrication , Glazing 1x24 mm DGU (6 acid +12+6)
W 7 (Glazing window ) made of Aluk SL50 (155 MM) Powder Coating fabricatio Glazing 6X34 mm DGU ( 8+18+8)
W8 ( Fixed window ) made of Aluk 45DS Powder Coating fabrication 1x24mm DGU (6 Acid Wash +12+6)
W10 (Fixed window ) made of Aluk 45DS Powder Coating fabrication3x24mm DGU (6 Acid Wash +12+6)
W11 (Fixed window ) made of Aluk 45DS Powder Coating fabrication3x24mm DGU (6 Acid Wash +12+6)
W13 (Fixed window ) made of Aluk 45DS Powder Coating fabrication 12x34 mm DGU (8+18+8)
W14 (Fixed window ) made of Aluk SL50(155mm) Powder Coating fabrication 12x34 mm DGU (8+18+8)
W15 (Glazing window ) made of Aluk SL50(155mm) Powder Coating fabrication 12x34 mm DGU (8+18+8)
W16 (Fixed window ) made of Aluk 45 Ds Powder Coating fabrication 4x24 mm DGU (6+12+6)
W17 (Fixed window ) made of Aluk 45 Ds Powder Coating fabrication 4x24 mm DGU (6+12+6)
W18 (Fixed window ) made of Aluk 45 Ds Powder Coating fabrication 4x31 mm DGU (8+15+8)
W19 (Fixed window ) made of Aluk 45 Ds Powder Coating fabrication 3x24mm DGU (6 acid +12+6)
W20 (Fixed window ) made of Aluk SL50 (155mm) Powder Coating fabrication 20 x24mm DGU (8+18+8)
W21 (Glazing window ) made of Aluk SL50 (155mm) Powder Coating fabrication 6x34 mm DGU (8+18+8)
W22 (Glazing window ) made of Aluk SL50 (155mm) Powder Coating fabrication 3 x34 mm DGU (8+18+8)
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete In trusses and trussed purlins in building including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.(Tata/SAIL or Jindal make)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.(Tata/SAIL or Jindal make)
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.(Tata or Jindal make)
Providing and fixing metal frame rink enclosures with metal frames having panel size 2.40mtr in length x1.20mtr in ht, made of MS rectangular pipe 80x40x3mm welded and embadded in base slab and both side covered with 12mm thick High Density Olyethylene (HDPE) panels with necessary screws etc. and top of the mertal frame covered with PVC cover with adhesive complete in all respect to the entire satisfaction of Engineer in Charge including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.
Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.
Kota stone slabs 20 mm thick in risers of steps, skirting,dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete in all respect including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying Laptto Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.
Providing and laying Antiskid floor tiles of size (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 ofapproved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.(Kajaria,Somany,Nitco, orient, RAK or equivalent make)300x300mm size including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.
Providing and laying vitrified floor tiles in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make like KAJARIA,NEXON,NITCO,STANZA, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete -- Size of Tile 600X600 mm (10to12mm thick) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.
Providing and fixing Ist quality 8mm -10mm thick ceramic glazed wall tiles conforming to IS: 15622 of approved make like KAJARIA,NEXON,NITCO,STANZA of size 600 x 600 mm , in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.( In skirting) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying flamed finish Granite stone work in walls, skirting flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 12 mm (average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified : -- Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make like KAJARIA,NEXON,NITCO,STANZA of size 600 x 300 mm , in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.
Prov. & Fixing 10 mm thick Unistone/durostone cladding Tiles with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement Complete inclding carriage of material maually and mechanically in all leads and lifts as per directions of Engineer-in-Charge
Providing and fixing flooring of AC-5 ) Laminated wooden laminates with comercial use planks of size (1195mmx154.5mmx12mm) along with warter proof memberane complete in all respect including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.
Providing and fixing responsive Active Sports Flooring with ,4.5mm thick glass fibre Roll of (size 1.80mx20.00mtr ) with adhesive as required as per sitre requirements complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.
Providing and fixing 0.60 mm thick pre-painted steel sheet (Tata/SAIL or Jindal make) in roofing with hot dipped metallic zinc / aluminium-zinc alloy coated sheet with top coat of regular modified polyester (RNP) organic coating of 20 microns over 5 microns primer coating to back coat of polyester of 5 microns over 5 microns primer coating including fixing with self driven steel screws / pre-painted iron J or L hooks or seam bolts with pre-painted limpet and rubber washers complete with all accessories as required and as per the detailed drawings including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.
Providing and fixing ridges or hips 60 cm overall with 0.60mm thick preprinted steel sheets in roofing (TATA /Century ) with hot dipped metallic zinc / zinc aluminium alloy coated sheets with top coat of regular modified polyester organic coating of 20 microns over 5 microns primer coating + back coat of polyester of 5 microns over 5 microns primer coating i/c fixing with pre-painted iron J or L hooks / self-driven screws, bolts & nuts 6mm dia & preprinted G.I. limpet and bitumen washers complete with all accessories as required as per the direction of Engineer in Charges including carriage of material up to all lead & lift and as per direction of Engineer In charge.(Tata/SAIL or Jindal make)
Providing and fixing valley 60 cm overall 0.60mm thick prepainted steel sheet in roofing with hot dipped metalic zinc coated sheet with top coat of regular modified polyster organic coating of 20 microns over 5 microns primer coating back coat of polyster of 5 microns over 5 microns primer coating i/c fixing with prepainted iron J or L hooks, bolts and nuts 6mm dia with prepainted G.I. limpet and bitumen washers complete with all accessories including carriage of material up to all lead & lift and as per direction of Engineer In charge.(Tata/SAIL or Jindal make)
Providing and fixing 15 cm wide, 45 cm overall semi_x_circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. 0.80 mm thick with zinc coating not less than 275 gm/m² including carriage of material up to all lead & lift and as per direction of Engineer In charge.(Tata/SAIL or Jindal make)
Providing and fixing M.S BP Sheet 1.66mm to 2mm thick (Tata/SAIL or Jindal make) in eaves board/facia/soffits/ceiling including cutting, fixing and welding to steel roof members and applying a coat of red lead primer complete including carriage of material up to all lead & lift and as per direction of Engineer In charge.
Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over G I Frame Structure and reinforced with Thick G I wire mesh fixed to G I frame ( Gi Frame work @6.00kg per sqm) including carriage of material in all leads and lifts as directed by the Engineer-in-charge.
Flat surfaces
Curved surfaces
Extra for sunk or raised mouldings in the plaster of Paris(Gypsum anhydrous) ceiling.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screwsof size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification including carriage of material up to all lead & lift and as per direction of Engineer In charge
12.5 mm thick tapered edge gypsum plain board confiring to IS 2095( Part-1):2011 ( Board with BIS Specifications
Providing and fixing 9 mm ply anti termite and water proof make od centuary or equivlent under ceiling with necessary screws/nuts & bolts/ nails fixed on wooden /steel frame work, complete including carriage of material up to all lead & lift and as per direction of Engineer In charge (Frame work shall be paid for separately).
Providing and fixing 12 mm thick readymade Pine wood planks in ceiling with tongued and grooved jointing with nails , screws on the wooden frame work 60cm c/c on either side with cover fillets to be easured and paid for separately) including carriage of material to all leads and lifts and as per direction of Engineer incharge.
Supplying and fixing new pine wooden fillets with necessary nails/screws wherever necessary complete to the entire satisfaction of Engineer in Charge including carriage of material to all leads and lifts and as per direction of Engineer incharge.
Providing 15 mm cement plaster on the rough side/ fair side of single or half brick wall of mix : ---- (a) 1:6 (1 cement: 6 fine sand) including carriage of material to all leads and lifts and as per direction of Engineer incharge.
Providing 6mm thick plaster of mix 1:3 (1 Cement : 3 Sand) including carriage of matearail in all leads and lifts as per the direction of Engineer in Charge.
Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on undecorated wall surfaces(two coats)to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials. including carriage of material to all leads and lifts and as per direction of Engineer incharge.
Painting on metal surface with Deluxe Multi ,Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture including carriage of material to all leads and lifts and as per direction of Engineer incharge.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth including carriage of material to all leads and lifts and as per direction of Engineer incharge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge) including carriage of material to all leads and lifts and as per direction of Engineer incharge.
Providing, laying, spreading and compacting graded stone aggregate (size range 53mm to 0.075mm) to wet Mix macadam (WMM) Specifications including premixing the materail with water at OMC in for all leads and lifts laying in uniform layers with mechanical paver finisher in sub base / base course on well prepared surface and compacting with vibratory roller of 10 tonne capacity to achive the desired density , complete as per specifications including carriage of material to all leads and lifts and as per direction of Engineer incharge.
Applying priming coat over new wood and wood based surfaces after and including preparing the surface by thoroughly cleaning oil,grease,dirt and other foreign matters sand papering and knotting.Ready-mix paint brushing with white lead for priming (Asian or Nerolac) including carriage of material to all leads and lifts and as per direction of Engineer incharge.
Painting two coat excluding priming coat with enamel paint to give an even shade on new wood and wood based surfaces/materials including cleaning the surface of dirt , dust and other foreign matter, sand papering and stopping including carriage of material up to all leads and lifts and as per direction of Engineer In charge.Readymixed paint other then white.
Applying Birla white wall care putty over plastered surface after thoroughly brushing the surface free from mortar drops dust, loose materials and other foreign matter sand papered smooth to give final finish to the surface complete up to all floor level. including carriage of material in all lead and lift & as per direction of Engineer in charge.
Wall painting with acrylic emulsion paint,having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour including carriage of material to all leads and lifts and as per direction of Engineer incharge.
Providing and applying Melamine polishing of approved brand on wood work (one or more coat) including carriage of material to all leads and lifts and as per direction of Engineer incharge.
Supplying and fixing of plastic chairs mounted on metal stand with powder coated around Rink area of approved quality complete in all respect as per the satisfaction of the Engineer -Incharge.
Supplying and fixing of Sofa chair with Table made of approved quality complete in all respect including carriage of material to all leads and lifts and as per direction of Engineer incharge.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes including carriage of material to all leads and lifts and as per direction of Engineer incharge. make Finolex
150 mm diameter
110 mm diameter
75 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. including carriage of material to all leads and lifts and as per direction of Engineer incharge. make Finolex
150 mm diameter Plain Bend
110 mm diameter Plain Bend
75 mm diameter Plain Bend
150 mm diameter Door bend
110 mm diameter Door bend
75 mm diameter Door bend
150x150x150 mm Plain Tee
110x110x110 mm Plain Tee
75x75x75 mm Plain Tee
150 mm diameter Coupler
110 mm diameter Coupler
75 mm diameter Coupler
Cowl 110 mm diameter
110mm PVC head
110mm PVC shoe
75mm PVC shoe
Providing and fixing unplasticised - GI Clamps of approved design fixed with steel screws and plastic plugs plugs, screwed with M.S. screws and making good the wall etc. complete including carriage of material to all leads and lifts and as per direction of Engineer incharge.
Providing and fixing Polyethelene-AluminiumPolyethelene PE-AL- PE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes the costs of cutting chases and including testing of joints complete including carriage of material to all leads and lifts and as per direction of Engineer incharge. make Jindal
(16 mm OD) pipe
(20 mm OD) pipe
(25 mm OD ) pipe
32mm OD ) pipe
Providing and fixing Polyethelene-Aluminium-Polyethelene PE-AL-PE Composite tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank - Sintex or equivalent including carriage of material to all leads and lifts and as per direction of Engineer incharge.
Providing and fixing Stain less Steel A ISI 304 (18/8) kitchen sink as per IS: fittings and brackets, cutting and making good the walls wherever required including carriage of material to all leads and lifts and as per direction of Engineer incharge.
Providing and fixing Jaguar wash basin Jaguar MAKE cat no CNS WHT811 , Pedestal CNS WHT 303 with single hole for pillar tap with CI or M.S. brackets painted white including cutting holes and making good the same but excluding fittings 480x420x150mm including pedestal including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Providing and fixing viterous china water closet Jaguar make Cat No.CNS-WHT-853S220SPPSM RIMLESS SINGLE PIECE WC with PP Soft close Slim seat cover , Duel Flush Cistern Fittings , Fixing Accessories Set. Size 370x665x750mm S. Trap -220mm including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Providing and fixing viterous china water closet Jaguar make CNS WHT 851S300SPP one piece with pp soft close seat cover, hinges, dual fluish cistern fitting fixing accessories set and cistern fittings size 370x690x680 mm including all fittings and accessories, Jaguar make including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Providing and fixing white vitreous china URS-WHT-13253N Urinal (Back Inlet) With Fixing Accessories, Size: 385x325x635 mm Jaquar make, FLV-1093NSQ, Metropole Flush Valve Regular, 40mm Size (Concealed Body) with Exposed Shut Off Provision &, 100mm Square Plate or equivalent make with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Providing and fixing Urinal Partitions, JSE-CHR-110UC450X, H: 900 W: 450 jaquar make including all charges for cost, carriage,and labour for fixing and making the wall good including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Providing and fixing Grab bar-Vertical Swing-Satin Jaquar Cat no. WAC-SAP-BG0800CS wall mounted or equivalentincluding fixing including carriage of material in all lead and lift as per direction of Engineer-in-Charge For disabled person
Providing and fixing grab bar-Vertical Swing-Satin Jaquar Cat no. WAC-SAP-BRO 6500 Cs 692 mm long Satin including fixing with necessary fittings / fixtures including carriage of material in all lead and lift as per direction of Engineer-in-Charge For disabled person
Providing and fixing 6 Kgf pvc Poly plast floor trap of self cleaning design with C.P screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors including carriage of material in all lead and lift as per direction of Engineer-in-Charge 110mm to 75mm diameter
Providing & Fixing hand shower (health faucet) Jaguar make Cat No. ALD-573 with 8 mm dia, 1.2 m long flexible tube & wall hook including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Providing and fixing Click Clack Waste 32mm Size Half Thread With 80mm Height - ALD-709 including Bottle Trap 32mm Size with 250mm & 190mm Long Wall Connection Pipes & Wall Flange ALD-769L250x190 including carriage of materials with in all leads and lifts (a) 32mm dia including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Providing and fixing 32mm dia PVC pipe for wash basin including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Providing and fixing bevelled edge miror of superior glass Saint Gobain/Modi guard or TATA make with C.P. set of stud and brass screws and washers including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Providing and fixing 600x120x5 mm glass shelf with edges round off supported on anodised aluminium angle frame with CP brass brackets and guard rail complete fixed with screw , rwl plug etc.including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Providing and fixing ACN-1151N, Toilet Roll Holder with Stainless Steel, Flap jaquar make including all cost, conveyance and labour charges etc complete including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Providing and fixing ACN-1135N, Soap Dispenser with Metallic Bottle, jaquar make including all cost, conveyance and labour charges etc complete including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Providing & fixing C.P. Towel ring Jaguar make Cat No. CAN-1121BN including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing and fixing KITCHEN FAUCET CON-309KNM Single Lever Sink Mixer with Swinging Spout (Table Mounted) with 450mmm Long Braided Hoses, jaquar make with all accessories including cutting and making good the walls wherever require including all cost, conveyance and labour charges etc including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Providing and fixing Bib cock (strainght line model) with wall flenge Jaguar make Cat No. CON-037KN with all accessaries including cutting and making good the walls wherever required including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Providing and fixing C.P. pillar cock with base flenge Jaguar make Cat No.COP-011PM including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Providing and fixing 100 mm stainless steel square grating of approved brand including cutting and making good the walls wherever required including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Providing & fixing shower mixer jagaur ORP-10681KPM and concealed body of single lever shower mixer ALD - 681 and shower no OHS - 1629 with shower arm 45 cm, and spout SPJ-10429 PM of Jaguar make including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Providing and fixing COP-057PM angular stop cock with wall flange, Jaguar make inccluding PVC connections of required ;length with all accessories including cutting and making good the walls wherever required including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Providing and fixing ACN-1131N, Soap Dish Holder, jaquar Make including all cost, conveyance and labour charges etc complete including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Providing and fixing COP-057PM angular consealed cock with wall flange, Jaguar make with all accessories including cutting and making good the walls wherever required including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Providing and fixing Double Coat Hook Jaquar make Cat No. AQN-7761 including cost, conveyance and labour charges etc complete including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with CI brating brick masonry cj\hamber with water tight CI cover with frame of 300x300mm Insde) the weight of the cover not less than 4.50kg frame to be not less then 2.70kg as per standard design (100x100 Size P Type) including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : - Inside size 90x80 cm and 60 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : - With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Inside diameter 80x90 cm and 60 cm deep including CI cover with frame ( Light duty 455x610 cm internal dimensions , total weight of cover 38 kg ( Weight of cover 23 kg and weight of frame 15kg)
Inside diameter 80x90 cm and 75 cm deep including CI cover with frame ( Light duty 455x610 cm internal dimensions , total weight of cover 38 kg ( Weight of cover 23 kg and weight of frame 15kg)
Inside diameter 80x90 cm and 90 cm deep including CI cover with frame ( Light duty 455x610 cm internal dimensions , total weight of cover 38 kg ( Weight of cover 23 kg and weight of frame 15kg)
Inside diameter 80x90 cm and 105 cm deep including CI cover with frame ( Light duty 455x610 cm internal dimensions , total weight of cover 38 kg ( Weight of cover 23 kg and weight of frame 15kg)
Inside diameter 80x90 cm and 120 cm deep including CI cover with frame ( Light duty 455x610 cm internal dimensions , total weight of cover 38 kg ( Weight of cover 23 kg and weight of frame 15kg)
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Supplying in cast iron cover with frame for man holes for frame of internal dimension 460x610mm rectanguler CI cover (light duty single sear pattern -I)the weight of frame 15 kg and of cover to be not less than 23 Kg including carriage of material upto all leads and lifts and as per direction of Engineer incharge
LANDSCAPE Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth in all kind of soil including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Seed Grassing with Special Grade -1 grass including watering and maintunance of the lawn for 30 days or more till the grass form a thick lawn free from weeds and fir for movoing including supplying good earth needed including carriage of materail in all leads and lifts as per the direction of Engineer in Charge.
Tree plants of appropreate sizes and then planting them at site after mixing of manure in duly dug area upto 0.90 mtr depth in specified or directed proportion including watering and removal of u/s material and i/c the cost of manure and carriage of material and plants. (Plants of mango , Guava, Arjun, Jacaranda , Caesaleinia Pulcherrima, Calateha Lutea, Ficus Pumila , Clusia Guttifera and Tecona stans etc. etc. ht. 0.60 mt.to 1.50 mtr) including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Tree plants of appropreate sizes and then planting them at site after mixing of manure in duly dug area upto 2.00 mtr depth in specified or directed proportion including watering and removal of u/s material and i/c the cost of manure and carriage of material and plants. ( Plants of Bottle Palm, Arica Plam Alstonia Scholaris, Bauhinia Purpurea, Golden Meleluca, Lagstonia Speciosa, Michaelia Champaka, Terminalia Catappa, Terminalia Mentaly and Veitchiamerrillii-Green. ht. 3 to 3.5mt) including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Tree plants of appropreate sizes and then planting them at site after mixing of manure in duly dug area upto 0.60 mtr depth in specified or directed proportion including watering and removal of u/s material and i/c the cost of manure and carriage of material and plants within all leads and lifts and as per direction of Engineer-in-charge.(Plants of Emermy, Golden Doranta, Euonymus , Hibiscus, Creeper rose, Lillies. Allamamda Neriifolia, Hymenotallis Littorails , Lantanana Sellowiana , Pennisetun Green ,Pennisetun Rubrum ,etc.ht. 0.30 to 0.45 mt)
Providing , installation ,testing and commissioning of drinking water cooler of Model SDLX150 Blue Star 150 litre or equivalent brand ,stainless steel body ,and in built purification system complete in all respect as per direction of Engineer Incharge / project Manager including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Providing and fixing SWB70L-3C Touchless Trash Bins TRIO AUTO BINS Stainless Steel 304 Dustbin Capacity - 30 Litres Dimensions - LxWxH 61 x 25.4 x 25.4 Centimeters including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Providing and fixing C.I. (Cast iron benches Super deluxe bench based on approved of with wooden/brown/yellow colour. Stand/legs made up of decorative cast iron material for mounting, 15 inches in width and weighing approximately 85kg complete including the cost towards loading/ unloading transportation fixing if applicable at site. including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Providing and fixing sign board of standard specifications dispalyed at different places in temple area as shown in the location plan. including carriage of material in all lead and lift as per direction of Engineer-in-Charge
SUB HEAD -1 ELECRICAL INSTALLATION WORKS Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant low smoke halogen free ( HRFRLS-LF) single core (flexible) copper conductor cable in surface/recessed PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS-LF/PVC insulated single core copper conductor cable as required.(Finolex/ Havells/Polycab/Lapp makes) including carriage of material in all lead and lift as per direction of Engineer-in-Charge
a) Group A.
b) Group B.
c) Group C.
Wiring for twin control light point with 1.5 Sq. mm. PVC insulated PVC insulated heat resistant flame retardant low smoke halogen free ( HRFRLS-LF) single core (flexible) copper conductor cable in surface/recessed PVC conduit, with 2-way modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required..(Finolex/ Havells/Polycab/Lapp makes) including carriage of material in all lead and lift as per direction of Engineer-in-Charge
Group C.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm PVC insulated heat resistant flame retardant low smoke halogen free ( HRFRLS-LF) single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Group A
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated heat resistant flame retardant low smoke halogen free ( HRFRLS-LF) , single core cable in surface/ recessed medium class PVC conduit as required. ((Finolex/ Havells/Polycab/Lapp makes) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire for 6A Sockets
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire for circuit wiring
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire as sub mains
4 X 6 sq. mm + 2 X 6 sq. mm earth wire as sub mains
4 X 10 sq. mm + 2 X 6 sq. mm earth wire as sub mains
4x16.0 Sq. mm.+2x6sqmm for earth connection for sub mains
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required (Finolex/ Havells/Polycab/Lapp makes) including carriage of material in all lead and lift as per direction of Engineer-in-Charge. 2 Pair
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required (Finolex/ Havells/Polycab/Lapp makes) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required AKG/BEC/Diplast/Poly plast make including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required Legrand/Havells/Schneider make including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Telephone socket outlet
TV Antena socket outlet.
BellPush
USB Charger
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required Lapp/D Link/ Finolex including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
1 run of cable
Supplying and fixing two module stepped type Modular electronic fan regulator on the existing modular plate switch box but excluding modular plate including making connections etc. as required. (Legrand/Havell,s/Schneider make) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-.(Legrand/Havell,s/Siemens make) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Single pole.
Supplying and erection of40/50/63 amp rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-(Legrand/Havell,s/Siemens make) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Double pole 32A.
TP&N MCB 40/63A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCBO), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
40Amp 2 Pole
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCBO), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
63Amp 4Pole
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-(Legrand/Havell,s/Siemens make) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Double door-8 way
Supplying and fixing of following way,horizontaltype triple pole and neutral sheet steel MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-(Legrand/Havell,s/Siemens make) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Double door-4 way
Double door-8 way
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required (Legrand/Havell,s/Siemens make) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
For 8 way, Double door SPN MCBDB
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required (Legrand/Havell,s/Siemens make) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
For 4 way, Double door TPN MCBDB
For 8 way, Double door TPN MCBDB
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
900 mm width X 62.5 mm depth X 2.0 mm thickness
Supplying and erection of following size of perforated HotDipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
450 mm width X 50 mm depth X 2.0 mm thickness
Providing, installing, testing and commissioning of ceiling fan and regulator, including wiring, the down road of standard length(upto 30 Cm.) with 1.5 Sq.mm. PVC insulated copper conductor single core cable etc. as required:(Crompton//Havells/Bajaj make) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Ceiling Fan 1400 mm sweep including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- (Crompton/Havells/ Bajaj make) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Exhaust Fan, Heavy duty, 380 mm sweep including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Earthing with Copper. earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Earthing with G.I. earth plate 600 mmx600 mmx 6 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Earthing with G.I. earth earth pipe 4.5m long,40mmdia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe 2.7m long etc. ( but without charcoal or coke and salt ) complete as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying and laying 8 SWG(4MM) G.I. wire On surface or in recess for loop earthing along with existing surface/recess conduit/submain wiring/cable as required as required.. Cost of 50 mtr. including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing and fixing 25 mm X 5 mm copper. strip on surface or in recess for connections etc. as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
63 mm dia (OD-63 mm & ID-51 mm nominal)
120 mm dia (OD-120 mm & ID-103 mm nominal)
160 mm dia (OD-160 mm & ID-135 mm nominal)
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required. including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade in the existing pipe or trench etc. of the required size:- (Havell,s or ISI make as approved by site incharge) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Armoured cable 6sq. mm (2 core)
Armoured cable 16sq. mm (4 core)
Armoured cable 70sq. mm (3.5 core)
Armoured cable 150sq. mm (3.5 core)
Armoured cable 240sq. mm (3.5 core)
Armoured cable 300sq. mm (3.5 core)
Providing and laying of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation and refilling the trench etc.as required, but excluding sand cushioning and protective covering:- (Havell,s or ISI make as approved by site incharge) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Armoured cable 6sq. mm (2 core)
Armoured cable 16sq. mm (4 core)
Armoured cable 70sq. mm (3.5 core)
Armoured cable 150sq. mm (3.5 core)
Armoured cable 240sq. mm (3.5 core)
Armoured cable 300sq. mm (3.5 core)
Extra for fixing the louvers/shutters complete with frame for exhaust fans of all sizes as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying and erection of Decorative pole 4.2m long of K Lite make Cat No.KP 4340,Model Cause way with decorative single arm bracket and 2 No Decorative 1 No.30W each LED fixtures of K Lite Cat No.KL-4517,Imperial Mini or equivalent along with 2way single door MCB DB with 6 Amp. complete in all respects as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying and erection of Hi Mast 10m Galvanised Octagonal steel ploe complete in all respects with electrical junction box at the base at the base with steel channel iron bracket for supporting 4 LED flood Light Fixtures complete in all respects as per manufacturer specifications of Bajaj ,Valmont or Equivalent makes as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing and fixing of Surface mounted 200 watt wipro make LED Flood light fixture IP 66 for lighting of Yards /Open areas cat no. LF 30-272-060-57-XX including connections, testing and commissioning as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing and fixing of LED batten for surface and anodized extruded aluminium housing, high transmittive diffuser Wipro make Cat no. LL20-111-XXX-65 NE3 20w complete with all accessories including connections, testing and commissioning as required. including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing and fixing of LED batten for surface and anodized extruded aluminium housing, high transmittive diffuser Wipro make 10w complete with all accessories including connections, testing and commissioning as required. including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing and fixing of Surface/Recess mounted 40W watt K lite make LED light fixture cat no. 3354 including connections, testing and commissioning as required or its equivalent as approved including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing and fixing of Surface mounted 10/12 watt K Lite make LED light fixture cat no.3342 including connections, testing and commissioning as required or its equivalent as approved by engineer in charge. including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing and fixing of Surface/ Recess mounted 7 watt K lite make LED light fixture cat no 3285.including connections, testing and commissioning as required or its equivalent as approved by engineer in charge including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing and fixing of Surface mounted 120 watt K Lite make LED Flood light fixture for facade lighting cat no. 4201 including connections, testing and commissioning as required or its equivalent as approved by engineer in charge. including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing and fixing of Surface mounted 60 watt K Lite make LED Flood light fixture for facade lighting cat no. 4200 including connections, testing and commissioning as required or its equivalent as approved by engineer in charge. including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing and fixing of Surface mounted 50 watt K Lite make LED Flood light fixture for facade lighting cat no. 6805 including connections, testing and commissioning as required or its equivalent as approved by engineer in charge including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing and fixing of Surface mounted 30 watt K Lite make LED Flood light fixture for facade lighting cat no. 4286 including connections, testing and commissioning as required or its equivalent as approved by engineer in charge including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing and fixing of Surface mounted 12 watt K Lite make LED Flood light fixture for facade/planter lighting cat no. 4271/72 including connections, testing and commissioning as required or its equivalent as approved by engineer in charge including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing and fixing of Surface mounted 10-12 watt K Lite make LED bollard light fixture for land scape cat no. 4799 including connections, testing and commissioning as required or its equivalent as approved by engineer in charge including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing and fixing fan box (nominal size) complete in all respect as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying and fixing of LED decorative fitting K lite make model. Imperial mini with IP65 protection., complete with accessories including connections as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Design as per technical specification and drawings manufacture, insure, pack, transport to site, store and erect in proper position , testing and commissioning of Double door with IP-65 protection lvl. cubicle pattern panel fabricated using 14 gauge CRCA MS Sheet steels/16 gauge CRCA for partition and vertical separations, Dust and vermin proof lockable doors, Single Compressions brass glands for Incoming/outgoing cables. Distribution panels shall be floor or wall Mounting type, having top/ bottom cable entry , front operated all complete with interconnections by tinned copper Bus Bars Color-coded heat shrinkable PVC sleeves and painted with powder coated process only with Egg shell white colored from inside and light gray from outside as per shade 631 of IS-5 including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Main LT Panel ( Load sharing Cum Sync. Panel) Incoming 2000A ACB 70 KA EDO Breaking capacity : 1 Nos ( As Incomer of Transformer) 2000A ACB 70 KA EDO Breaking capacity : 1 Nos ( As Bus coupler)) 800A 50KA ACB EDO :3 Nos (As Incomer of 500 and 250 KVA DG Sets) Required Neutral Contactors and PLC for load sharing and synchronisation shall be provided along with power managers and indication lamps for all incong feeders Out going 800 Amp70 KA 4P ACB EDO as incomer for AC Panel 400A 35 KA TP MCCB :2 Nos 250A 35 KA TP MCCB :2 Nos 125A 25 KA TP MCCB :2 Nos 80A 25 KA TP MCCB : 4 Nos
Capacitor Panel 300 KVAR complete with 8 steps APFCR with following capactor banks complete with MCBs and capacity duty contactors and 320A incomer MCCB.3x20 KVAR+6x40KVAR including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Floor Panels for MCB DISTRIBUTION BOARDS Incoming : 250A MCCB Outging: 80A 16KA TP MCCB:8 Nos 40A TP&N MCB 10KA :240A DP MCB 10KA :2Indication lamps and multifunctional meters shall also be provided with panels including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying installation testing and commissioning of foot light/step light philips make Model No 30974, Colur White materail, Aluminium 2watts , lumen/ CCT:30Lm/3000 KK indpoor applicatiions including making connections, Testing etc, Philips, Jaguar,/ Wipro or equivelent as approved including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supply , Installation ,Testing & commissioning and fixing of control panel of suitable size out door mounting type made out of 1.6 mm thick MS Sheet front opnable cabinet with locking arrangement and duly powder coated for campus lighting It shall also consist 32 A DP MCB incomer and 4 No. 6Amps MCB housed in 6Way SP&N MCB DB, single dial time switch, 25 A TP contractor for the automatic switching of luminaries ,with 2 no. 9A contractor 2.5 sq. mm cable complete in all respect including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supply, Erection, Testing and Commissioning of Silent DG Set Three Phase, 415Volts, 50Hz, 1500 RPM Silent (Sound Proof) Diesel Generator Set (with AMF panel). It should be water cooled/air colled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard). ENGINE: The Diesel engine developing suitable BHP for giving a power rating as per ISO 8528- Part-1 ( With CPCB-II Norms) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements. ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication. ALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor: 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled Alternator should have 40 degree maximum class H insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use. along with RCC foundation of DG Set of required size.(Makes Sudhir Power,Kirloskar,MTU) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
500 KVA Capacity
250 KVA Capacity
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. (Heat Detector ) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. (Smoke Detector ) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying, installation, testing & commissioning of addressable fire control module complete as required for AHU,Access System,Lift etc tripping including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying, installation, testing & commissioning of addressable fire Monitor module complete as required for monitoring Sprinkler including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying, installation, testing & commissioning of addressable manual call point complete as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
2 X 1.5 sq. mm
Supplying and fixing of following sizes of steel conduit alongwith accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the sam in case of recessed conduit as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying and fixing of Double sided LED signage with built in battery back-up for 2 hrs.and all other fixing accessories as required ( BAJAJ cat. No. 220211 BESL 03 LED DSD WBB Red ) or equivalent approved List of make including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
SUB HEAD -4 : PUBLIC ADDRESS SYSTEM Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying, installation, testing & commissioning of digital audio amplifier 500 Watt , 25V rms operating at 240 Volt AC Supply complete as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
SITC of 42 U Mounting Rack with ventilation, sliding shelves, power strips, etc. all complete including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Speaker cable Single pair, 2-core, 1.5 sqmm including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
25 mm dia
SUB HEAD -5 : CCTV SYSTEM SITC of 1/3-inch, CCD sensor color IP indoor UL / FCC listed dome camera with Progressive scan 4CIF resolution, Vari Focal lens 3.8 mm to 12 mm F1.2 auto iris , sensitivity 0.012 lux @ 30 IRE (Night Sense), Quad-stream video simultaneously — two H.264 streams, an I-frame recording stream and an M-JPEG stream, Removable MicroSD card for built in recording, POE enables, two way audio and audio alarm, ONVIF Compliant, Tamper and Motion Detection, operating temperature -20 to +50 deg cel., complete with Dome Housing IP 66 and NEMA‑4X, Connectors, Lens, Camera Mounts, Power Supply and all Ancillary Equipment & all accessories as per technical specification and should be UL listed including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
SITC of 1/3-inch, CCD sensor color IP outdoor UL / FCC listed BOX camera with Progressive scan 4CIF resolution, Vari Focal lens 5 mm to 50 mm F1.2 auto iris , sensitivity 0.012 lux @ 30 IRE (Night Sense), Camera should fully Support iscsi recording, Quad-stream video simultaneously — two H.264 streams, an I-frame recording stream and an M-JPEG stream, Removable MicroSD card for built in recording, POE enables, two way audio and audio alarm, ONVIF Compliant, Tamper and Motion Detection, operating temperature -20 to +50 deg cel., complete with Dome Housing IP 66 and NEMA‑4X, Connectors, Lens, Camera Mounts, Power Supply and all Ancillary Equipment & all accessories as per technical specification and should be UL /FCC listed including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
SITC of Managed Layer -2 Switch with Power on Ethernet (PoE) enabled, with 24 nos. 10/100 base Tx PoE port, 1 no. dual personality Gbe Port for copper/fiber uplink, 3.7 Gbps switching capacity, 2.7 MPPS forwarding rate, maximum power consumption 135 watt including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
SITC of Minimum server hardware requirements: a. Intel® Xeon® X5670, 2.93GHz, 12M Cache, Turbo, HT, 1333MHz b. 8TB memory, 1333MHz dual ranked Registered DIMMs (RDIMMs), advanced ECC c. Microsoft Windows Server® 2003 Server R2, Standard Edition (32-bit) or higher d. 146GB 10K RPM Serial-Attach SCSI 6Gbp or higher e. DVD+/-RW, SATA, Internal f. Dual Integrated 100/1000 Ethernet NIC g. I/O Expansion Option h. Keyboard and Optical Mouse i. Monitor 32 inch flat LCD panel including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
SITC of 12 U Mounting Rack with ventilation, sliding shelves, power strips, etc. all complete including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
SITC of 42 U Mounting Rack with ventilation, sliding shelves, power strips, etc. all complete including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
WIRING Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
1 run of cable including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supply, Installation, Testing & Commissioning of OFC Patch Cord including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge. 3 X 1.5 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge. 25 mm dia
FIRE FIGHTING TERRACE PUMP TERRACE PUMPSET Supply,Installation and Commissioning of Terrace Pumpsets duly coupled type bronze impeller and SS shaft on MS Channel on concrete base with discharge of 900 LPM @ 55 Mtrs Head including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
TERRACE PUMP STARTER PANEL Providing fixing and testing and commissioning of DOL Starter panel for terrace pumpsets duly fabricated in powder coated MS Box with MCCB incoming,Voltmeter and Ammeter for auto start through Pressure Switch including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
PRESSURE SWITCH Providing and fixing of Pressure switch of approved make in MS pipe line suitable for line presure up 15kg/cm2 & including connection with main panel etc. as required complete in all respects for Hydrant, Sprinkler, Standby and Jockey pump including necessary wiring upto control panel & other materials including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
PRESSURE GAUGE Providing and fixing Pressure Gauge complete as required complete in all respect . Dial diameter 100mm calibration 0-16 Kg including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
BUTTERFLY VALVES Supplying, Laying, Testing and Commissioning of ISI marked BUTTERFLY VALVE PN 1.6, with Gun metal seal duly ISI marked complete with rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete in all respect including carriage of material in all lead and lift as per direction of Engineer-in-Charge. 100 mm dia
NON RETURN VALVE Proving & fixing ISI Marked Dual Type Non-return valves flanged end class PN-1.6 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc complete100mm dia(Dual Type NRV) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
INTERNAL FIRE HYDRANT M.S Pipe Providing, laying, fixing, testing and commissioning of 'C' Class Heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling and painting with two or more coats of synthetic enamel paint of required shade complete in all respects. (Below 50mm Pipe all Pipes should be threaded type) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
BRANCH PIPE Supplying, Installation, Testing and Commissioning 63 mm dia Stainless Steel Branch Pipe (ISI marked) with 20mm (nominal internal dia) size Stainless Steel nozzle confirming to IS 903, suitable for instantaneous connection to interconnect hose pipe coupling as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
FIRST AID HOSE REEL DRUM Providing and fixing first aid hose reel full swinging type including cabinet with 30 m length x 20 mm dia rubber lined pipe with ABS plastic shut off nozzle of 6 mm dia. The hose reel will conform to IS requirements. Rate will 25 mm dia pipe connection from riser to hose reel including flexible pipe, sockets, nipples, elbows including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
HAND APPLIANCES Providing and Fixing with Brackets/ Supports etc. Wall/ Floor Mounted Fire Extinguisher as per detail given below: Providing and Fixing with Brackets/ Supports etc. Wall/ Floor Mounted Fire Extinguisher as per detail given below:ABC STORED PRESSURE FIRE EXTINGUISHER Providing and fixing of FIRE EXTINGUISHER, ABC Powder type (stored pressure) as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
6kg Capacity
4kg Capacity
TOTAL OF HAND APPLIANCES SPRINKLER SYSTEM Providing, laying, fixing, testing and commissioning of 'C' Class Heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling and painting with two or more coats of synthetic enamel paint of required shade complete in all respects. (Below 50mm Pipe all Pipes should be threaded type) Make: Jindal (Hirar), Tata, Surya Prakash including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
ALARM GONG BELL Providing & Fixing of installation Manually Operated Electric Fire Alarm System including carriage of material in all lead and lift as per direction of Engineer-in-Charge. Make: 150mm
SPRINKLERS Providing,fixing and Testing of UL Listed quartzoid bulb type Sprinklers head to operate at 68 degree Centigrade. Make: Make: Omex, Tyco, HD Pendent Type Sprinklers including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
HVAC SYSTEM Sub Head 'A' - MachineryAir Cooled Screw Chiller (with VFD) Supply ,Installation, Testing and Commissioning of AHRI/Eurovent certified Rotary Screw Air cooled Chilling M/C of 80 TR actual capacity at tender operating conditions (as mentioned below) with R - 134a refrigerant (ozone friendly, HFC) ar any other refrigerant as per NBC 2016 norms meeting all functional requirements and approved by E-I-C, semihermatic / hermetically sealed single /multiple compressors with mono/twin screw complete with single/multi refrigerant circuit, driven by suitable KW Squirrel Cage induction motor complete with insulated shell and tube flooded chiller, with S.S braided pipe flexible connector, insulation to be mechanically protected similar to chilled water piping insulation, flanged end for chiller & condenser, electronic auto setting WATER flow switches at chiller outlet, factory done refrigerant piping, refrigerant and oil first charged, microprocessor based control panel , motor drive by floor mounted air-cooled VSD/VFD with IP54 or better as per OEM standards enclosure , factory installed electrical disconnect / isolator switch integrating main fuses etc. all mounted on M.S. frame. Motor shall be suitable for 415 volts ± 10%, 50Hz ± 5 %, three phase A.C. supply, class F insulation & IE -3 rated. Chillers shall be provided with spring isolators. The Condenser Fan control shall be provided with VFD.It should include flow switch/DP switch at chiller and condenser, vibration isolators, including oil separators, pressure relief devices, filter drier moisture indicators, refrigerant economizer, integral refrigerant piping and wiring, accessories as required and called for, automatic and safety controls mounted in central console panel.dB Level shall not be more than 82 @ 1.5 m or as per relevant norms. The unit will be with compressor accoustic jacketing for noise/vibration reduction. Cost for Suitable PCC/RCC foundation ( PCC foundation in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate 30 cm above floor level including making connection of inlet & outlet with fittings including nut, bolts, packing etc.) with plaster is deemed to be included in this item cost along with spring isolators including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
The cost of chilling machine shall be inclusive of BMS interface card for integration with BMS System & any deration in capacity to be accounted in arriving at the actual capacity of chiller .Chiller WATER in : 7o C WATER out : 12o CWATER flow rate: 215 USGPM (min.) OUTDOOR CONDITION-DB-90Deg F/WB-75 Deg F Chillers complete in all respect - (2W+1S) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Primary Chilled Water Pumps Set Supply, installation, testing and commissioning of vertical Inline Pump/ Vertical/Horizontal split casing , back pull out flexible coupled End Suction Pump mounted on a common base with electric motor for re-circulation of Water for the central air conditioning system. The pumps shall be flexible coupled protected by OSHA complaint coupling guard, with CI casing, SS (CF8) /bronze impeller, high strength steel shaft (prefarably SS 304) and MS fabricated base plate .The pump motor shall be suitable for 415± 10% volts, 50 cycles, 3 phase AC power supply of (IE3) efficiency class. Motor shall be squirrelcage with Class F insulation, 1500 RPM(Max.) Pump, base, coupling and motor shall be factory assembled. The capacity of motor shall be at least 10% in excess of BHP requirement of pump. The internal components of pumps including mechanical seal shall be suitable to sustain a temperature of 122 degree Fahrenheit. Minimum efficiency of pump shall be as mentioned below. Cost for pump foundation, suitable support/Mounting Arrangement including making connection of inlet & outlet with fittings including nut, bolts, packing etc.)withplaster, Antivibration arrangement of cushy footmountigs is deemed to be included in this item cost. Suction guide to be provided by pump manufacturar for unit responsability. Pump curves & loss calculations shall be furnished during approval from competant authority. Pumps shall be BMS compatible. Pump rating shall be PN 16 preferably. Contractor to submit proposed pump model with duty curve. Water flow rate : 215 USGPM Head : 46ft./14m Motor HP :5.5 HP (suggested) or as per OEM standard & meeting the functional requirements Efficiency(Min) : 75 % or nearest as per OEM Pumps complete in all respect (2 working+1 standby ) Secondary Chilled Water Pumps Set With VFD including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supply, installation, testing and commissioning of Vertical Inline Pump/Vertical/Horizontal split casing , back pull out flexible coupled End Suction Pump mounted on a common base with electric motor for re-circulation of Water for the central air conditioning system. The pumps shall be flexible coupled protected by OSHA complaint coupling guard, with CI casing, SS (CF8)/bronze impeller, high strength steel shaft (prefarably SS304) and MSfabricated baseplate.The pump motor shall be suitable for415±10% volts,50 cycles,3 phase AC power supply of (IE3 ) efficiency class. Motor shall be squirrelcage, Class Finsulation,1500RPM (Max.). Pump, base, coupling and motor shall be factory assembled. adjustable & compleet in all resepct as per directions of E-I-C. The capacity of motor shall be at least 10% in excess of BHP requirement of pump. The internal components of pumps including mechanical seal shall be suitable to sustain a temperature of 122 degree Fahrenheit. Minimum efficiency of pump shall be as mentioned below. Cost for pump foundation, suitable support/Mounting Arrangement including making connection of inlet & outlet with fittings including nut, bolts, packing etc.) with plaster. Pumps Shall be BMS & VFD compatible. Suction guide to be provided by pump manufacturar for unit responsability. Contractor tosubmit proposed pump model with duty curve. Pump rating shall be PN 16 The chilled Water pumps shall also includethe cost of thermal insulation. Secondary chilled water pumps shallbe suitable for operation on variable frequency drives & conforming tothespecifications of variable speed pumpingsystem. The capacity of motor shall be at least 10% in excess of BHP requirement of pump. Secondary Chilled Water pump Water flow rate : 215 USGPM Head : 82 ft./25m Motor HP :7.5 HP (suggested) or as per OEM standard or meeting functional requirements Efficiency : 75 % or nearest as per OEM Pumps complete in all respect (2 working+1 standby ) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Variable Speed Pumping System controller for Secondary Pump Supply, installation, testing and commissioning of separate Primary Variable pump controller with IP55 Protection, sensorless/wireless control for the redundancy of VSPS (variable Speed Pumping System). The controller should stage or destage the pumps based on BEP(Best Efficiency Point) for the optimum efficiency of variable speed pumping system. Controller should be BMS compatible for Modbus/Bacnet connectivity. Minimum 2 Nos of wireless sensors should be considered for each zone. All variable pumps shall have remote monitoring facility to connect data to cloud server for active performance management and real-time alerts for analysis and early diagnostic messaging and real time trends. For 3 No. of 7.5 H.P Secondary Chilled Pumps (2W+1 S) Closed Type Pressurized Expansion Tank (Chilled Water Line) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supply, installation, testing and commissioning of closed expansion tank system. Tank will be of M.S. construction with interchangeable EPDM-BUTYL rubber membrane. The expansion tank shall be complete with safety relief valve and pressure gauge. The tank will be of pressure rating to suit the system pressure and will be sized to adequately compensate for water expansion due to operating temperature variations.the tank shall be fabricated as per ASME and must be ASME stamped for 250 PSIG operating pressure. For chilled water application, it will be insulated with 50 mm thick insulation to the specifications and cladded with 26G-aluminum cladding. The capacity of tank shall be 500 Liters including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supply, installation, testing and commissioning of pressurisation unit shall be with 2 nos. (1 working + 1 stand by) vertical multi-stage pumps of suitable rating & capacity, as indicated hereunder, factory mounted on a steel frame along with interconnected piping, valves, strainer, pressure gauge, pressure transmitter, flow meter to measure the make-up water quantity, control panel with duty cycling and dry-run protection, electrical relays/contactors and interconnecting wiring:The unit shall be capable of Pressurising the system to the required pressure with suction from a break-tank located at least 1m above pump level. Flow 2CMH (60mwc) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
AIR HANDLING UNITES -With VFDs Supply, installation, testing and commissioning of factory built draw through type floor mounted Double skin type air handling unit. Double skin panel shall be 0.8 mm thick precoated GSS on outside and 0.8mm plain GI Sheet on inside with puf insulation of 25mm thick of density 38kg/cum injected in between and a gasket for thermal break. The main fram work is hollow aluminium profile .Fresh air & return air mixing chamber with aluminium damper to regulate fresh air and return air. Filter section with pre filter (MERV-8) of 50mm thikness having an efficiency of 90% down to 10 micron prticle size . Coil section of copper tube (minimum thicness 0.35mm and 12.7mm tube dia OD) with Aluminium fins (5 fins/cm) 6 row deep Water coil with copper headers drain pan of 20G SS duly insulated and sloped for proper drainage Blower section with AMCA cerified IDDW backward curved type fan with motor drive suitable for 415±10% Volt ,3phase Ac supply with anti vibration mountings and a flexible convas connection at inlet/outlet. Supply air blower section with VFD control, etc complete as required. FM AHU F/M 35000 CFM, 60 TR,60 mm SP,4 RD Coil SUGGESTED OR AS REQUIRED MEETING FUNCTIONAL REQUIREMENT including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
C/S AHU
C/S 2400 CFM 7.0TR 45 mm SP,4 RD Coil SUGGESTED OR AS REQUIRED MEETING FUNCTIONAL REQUIREMENT
C/S 2200 CFM 4.0 TR 45 mm SP,4 RD Coil SUGGESTED OR AS REQUIRED MEETING FUNCTIONAL REQUIREMENT
C/S 1600 CFM 3.0TR 45 mm SP,4 RD Coil SUGGESTED OR AS REQUIRED MEETING FUNCTIONAL REQUIREMENT
C/S 1200 CFM 4.0TR 45 mm SP,4 RD Coil SUGGESTED OR AS REQUIRED MEETING FUNCTIONAL REQUIREMENT
800 CFM (2.0 TR)
1000 CFM (2.5 TR)
Thermostat Supply, installation, testing and commissioning of automatic control for Units for 2 pipe system ( cooling) consisting of snap acting digital thermostat, which will have provision of setting of room temperature, setting offan speed (High, Medium, Low). The quoted price of thermostat shall include the cost of 20mm MS conduits, control cabling, MS Box etc. as required. It shall include all accessories,mountings,wiring be tween thermost at & unit,terminations etc. (BMS Compatibility to be provided). including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supply, installation, testing and commissioning of automatic control for Units for 2 pipe system ( cooling type) consisting of Modulating thermostat, It shall include all accessories,mountings,wiring & unit,terminations etc.(BMS Compatibility to be provided) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Tube Axial Fans Supply, installation, testing and commissioning of AMCA certified for sound and air performance (FEG) Tube Axial fan complete with tube casing in MS standard construction powder coated, aluminium impeller with adjustable blade angles,vibration isolator and directly coupled to TEFC Sq.cage induction motor, suitable for 415V±10%, 50 Hz. 3 phase electric supply complete with required hardware etc. as per specification complete as required. A) Air Quantity : 4000 CFM B)Static Pressure : 20 mm wg C)Duty : Fresh/Exhaust including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Air Quantity : 2300 CFM Static Pressure : 15 mm wg Motorrating : As Required
Air Quantity : 1500 CFM Static Pressure : 15 mm wg Motorrating : As Required
Air Quantity : 1200 CFM Static Pressure : 15 mm wg Motorrating : As Required
Air Quantity : 700 CFM Static Pressure : 10 mm wg Motorrating : As Required
Air Quantity : 500 CFM Static Pressure : 10 mm wg Motorrating : As Required
Factory Fabricated Double Skin Air Washer Supply, installation, testing and commissioning of factory fabricated Double Skinned Air-washer unit floor mounted type fabricated out of extruded aluminum section with 0.6mm pre-plasticized / pre-coated Galvanized steel sheet outside 0.6 mm plain Galvanized steel sheet inside with blower, blower section and blower motor TEFC (IE-3) type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, belt drive package, wet section & tank shall be made of 18 G stainless steel.The Air-washer shall be complete with fill of depth 200 mm & face velocity across the fill shall be limited to 152 MPM. The Air-washer shall have an efficiency of 90% & shall be complete with water circulation pump -2 No.(1W+1S), GI B Class interconnecting piping, Aluminum viscous filters. makeup, quickfill and drain connections, Butterfly/Gate valves for Pumps, make up, drain & quickfill connections of Sump, 2 No. pumps of suitable capacity (1W +1 S), Y strainers and necessary fittings etc. Suitable PCC/RCC foundation with plaster, Antivibration arrangement of cushy foot mountings etc.in all respect shall be in contractor's scope. The Air-washer shall have an efficiency of 90% & shall be complete with water circulation pump GI B Class interconnecting piping & valves Aluminum viscous filters, fire retardant double canvass connection etc. The airwasher panels shall be insulated with 23mm thick & 36 Kg/m³ density PU foam. The Airwasher shall conform to specification given in the tender & shall be of following capacity. Motor Kw is indicative only, actual as per requirement to be included during installation. Air Qty :11500 CFM Static Pressure : 40 mm wg Fan Motor HP :15 HP(Suggested) or as per requirement Pump Motor HP : 0.5 (Suggested) or as per requirement including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
DRY SCRUBBER Supply, Installation, Testing and Commissioning of Scrubber each comprising of extract air intake section, electrostatic precipitation technology, dry type air cleaner to remove oil, smoke and fumes from exhaust air, as per the Specifications. Electrostatic section shall be made of 16 gauge galvanised sheet, high bake epoxy powder coated, washable type aluminium mesh pre filters, Ionizing-Collecting cell(s) . High voltage support insulators shall be of made of Teflon, glazed to enhance dielectric strength and retard tracking. Average efficiency of 90% to 95% for single pass base on ASHRAE test method at flow rates of 800 –1800CFM per module. Power supplies shall be 100% solid state CE Listed, Module of capacity above 3000 CFM shall be equipped with Pulse width modulating (PWM). The system should allow connection to a fan section to achieve 500 FPM - 650 FPM velocity across the air cleaner. All unit shall be with factory fitted UV03 lamp as per specification etc complete as required. Operating Voltage : 220V, 50 Hz Ionizing Voltage: 12.5 to 13 KV DC Collector Cell Voltage : 6 to 6.5 KV DC Power Consumption : Not more than 50W per cell. Filter capacity 13500 CFM including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying, installing, testing and commissioning of SISW (Single inlet single width) centrifugal fan as per specification, with statically and dynamically balanced backward curved blades, galvanized steel housing, maintenance free bearings, belt driven complete with totally enclosed fan cooled squirrel cage induction motor, centrifugal fan belt drive and vibration isolators. Motor shall be suitable for 415±10% volts, 50 cycles, 3 phase AC supply & meeting criterion asperASHRAEstandard 90.1-2016and high efficiency (IS 12615) . Minimum 20 mm (WC) external static pressure after fan outlet. Duty: Kitchen Exhaust Capacity: 13500 CFM Static Pressure : 35 mm wg Fan Motor HP : 15HP or as per requirement including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Sub Head-'B'- Chilled Water Piping,Fittings & Valves INSULATED CHILLER PIPING Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
150 mm dia.(32 mm thick insulation)
125 mm dia. (32 mm thick insulation)
100 mm dia.(32 mm thick insulation)
40 mm dia.(32 mm thick insulation)
32 mm dia. (32 mm thick insulation)
25 mm dia. (19 mm thick insulation)
INUSLATED VALVE Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Butter fly Valve(Manual) with CI body SS Disc,Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot water circulation as specified including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
100 mm dia Lever Type
40 mm dia Lever Type
Providing and fixing in position the following Ball Valves without strainer duly insulated as per specifications and drawings. Ball valve shall be screwed type brass/bronze lever operated, quarter turn ball valve (screwed type) of full flow with bronze /forged brass hard chrome plated ball with setting & gland of superior quality of preferably PN 16 rating. 32 mm dia including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing and fixing in position the following Ball Valves with strainer duly insulated as per specifications and drawings. Ball valve shall be screwed type brass/bronze lever operated, quarter turn ball valve (screwed type) of full flow with bronze /forged brass hard chrome plated ball with setting & gland of superior quality of preferably PN 16 rating including carriage of material in all lead and lift as per direction of Engineer-in-Charge. 32 mm dia
Balancing Valve with built in measuring facility with CI body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. 100mm dia. including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Non Return Valve with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified. It shall be of wafer type preferably with flanged ends. It should be tested for required hydrostatic pressure for shell & seat as per OEM & shall be suitable for maximum working temperature of 80 degree C (approx.). 100 mm dia. including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Y-Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specified including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
100 mm dia
40 mm dia
Providing and fixing in position the industrialty pepressure gauges with gunmetal / brass valves complete as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing & Fixing in position the mercury in glass with industrial type thermometers including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
PRESSURE INDEPENDENT CONTROL VALVE Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
32 mm Dia
40 mm Dia
100 mm Dia
(Valves Station) Connection and regulation kit for HVAC fan coil units in heating and cooling systems. Complete with: pressure independent control valve with proportional linear actuator, three-way shut-off valves, integrated by-pass, Venturi device with pressure test ports (only for dedicated versions), filtering cartridge and pre-formed shell insulation made of PPE. Sizes DN 15, DN 20 and DN 25. Linear or equipotential flow rate adjustment characteristic, which can be set up by actuator depending on the characteristics of the terminal unit. Maximum working pressure 25 bar. Maximum differential pressure with actuator installed: 5 bar. Nominal operation Δp range 25–400 kPa. Working temperature range -10−120°C. Ambient temperature range 0−50°C. Strainer mesh size 800 µm. Medium: water and glycol solutions; maximum percentage of glycol 50%. Dezincification resistant alloy body and adjustment headwork; stainless steel strainer mesh; EPDM diaphragm, obturator and seals. 25 mm dia for AHU/FCU including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing, fixing, testing & commissioning of resilient rubber lined double arch vibration eliminator expansion bellow suitable for raw water up to 45 deg. C temperature to provide relief from stresses at pipe flanges. It should be complete as per manufacturer's specifications & as directed by Engineer- in-charge.(PN 16 rating) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
100 mm dia
Providing and fixing Auto air vents (Brass MOC)
Providing and fixing in position the following water flow switch as per specifications including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Drain Pipings Providing and fixing of PVC drain pipe of 6 Kg /cm2 pressure rating complete with 6mm thick closed cell nitrile rubber insulation with mechanical protection (Aluminium laminated face), fittings, supports, valves as per specifications & drawings including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
25 mm dia
32 mm dia
Sub Head 'C' - Air Distribution Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
0.63 MM (24 gauge) Galvanized Sheet Steel Ducting
0.80 MM (22 gauge) Galvanized Sheet Steel Ducting
1.0 MM (20 gauge) Galvanized Sheet Steel Ducting
1.25 MM (18 gauge) Galvanized Sheet Steel Ducting
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
0.63 MM (24 gauge) Galvanized Sheet Steel Ducting
0.80 MM (22 gauge) Galvanized Sheet Steel Ducting
1.0 MM (20 gauge) Galvanized Sheet Steel Ducting
1.25 MM (18 gauge) Galvanized Sheet Steel Ducting
Supply, fabrication, installation and testing of Kitchen duct with wire wraping complete in all respects, on kitchen exhaust ducts to provide minimum 1 Hr fire rating. 16 gauge MS duct work welded construction. Duct shall have fire rated coating compound. Fire rated coating compound used forconstruction of fire rated duct work shall be protected with minimum 0.7mm to 1mm nominal thickness tested to properties as per the requirements of BS 476: 6 & amp; 7, including non-combustibility Class O and fire propagation - Class 1 surface spread of flame & amp; materials in accordance with building regulations. including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supply, fabrication, installation and testing the non-porous 300mm dia flexible connections constructed of fire resistance flexible, double canvas connection with resistoflex material as per the approved shop drawings including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers as per specifications including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
FIRE DAMPERS Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Fire damper
Actuator
Supply, installation and balancing of extruded aluminium powder coated air louvers complete with aluminium wire mesh bird screen as per specifications including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Fresh air louvers (with collar dampers)
Exhaust air louvers (without volume control dampers)
DUCT THERMAL & ACOUSTIC INSULATIONA A) Supplying and fixing of External Thermal duct insulation with closed cell Nitrile rubber (Class “O”) insulation on ducting after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation, facotry laminated 7 mil woven fiber glass cloth on insulation finally finished with 2 layers of STARBOND 30-36 to provide complete seal against air and moisture complete as per specifications and as required. B) Insulation material for Duct shall be anti-microbial closed cell Elastomeric Nitrile Rubber. Thermal conductivity of the insulation material shall not exceed 0.038 W/moK or 0.212 BTU / (Hr-ft2-oF/inch) at an average temperature of 30oC. Density of the nitrile rubber shall be 45-55 Kg/m3. The product shall have temperature range of –40 oC to 105oC. The insulation material shall be fire rated for Class 0 as per BS 476 Part 6 : 1989 for fire propagation test and for Class 1 as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapour permeability shall be not less than 0.024 perm inch (2.48 x 10-14 Kg/m.s.Pa i.e. µ=7000: Water vapour diffusion resistance). Thermal conductivity of the material shall not be affected by ageing, as per DIN 52616 The smoke density of the material as per AS-1530.3 shall not exceed 1.The material shall be antimicrobial as per ISO 22196, C1338 and ASTM G21-96. There shall be no growth of fungus and mold including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
19 mm thick
25 mm thick
Supply and fixing of acoustic lining of supply air duct and plenum with 13 mm thick with Engineered Nitrile Rubber open cell foam with Density 140 - 180 Kg/m3 and Class 1 Fire Performance and with antimicrobial protection and should pass Fungi Resistance as per ASTM G 21 and Bacterial Resistance as per ASTM E 21 complete with manufacturer's recommended Rubber based Adhesive in a blend of solvents etc complete as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying, fixing acoustic lining on wall and ceiling of AHU roomswith 50mm thick, density 32 kg/cu.m resin bonded glass fiberinsulation friction fixed in 610mm x 610 mm frame work made of25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shapedchannel and covered with reinforced fiber glass tissue and finishedwith 0.80 mm perforated aluminium sheet etc. complete as requiredand as per soecifications including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Out Goings FOR AHU VFD Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
MS Cable Trays Supplying and installing following size of perforated paintedwith powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
Supply of LT cable Supply, following sizes of PVC sheathed XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
3 ½ C - 150 sq mm Aluminium
4C- 10 sq mm Aluminium
4C- 6 sq mm Aluminium
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm dia. ISI marked, steel conduit including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge. 25 mm dia. ISI marked, PVC conduit
WIRING IN EXISTING CONDUIT / PVC CASING CAPPING WITH COPPER CONDUCTOR Supply,& drawing following sizes of FRLS PVC insulated copper conductor ,single core cable in the exixsting surface/reccessed steel/pvc conduit as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
2Cx 1.5Sq mm
4Cx 2.5sq.mm
EARTHING SYSTEM Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing aling with existing surface/recessed conduit/submain wiring/cable as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge. 6 SWG
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Air Cooled Screw Chiller (with VFD) Supply ,Installation, Testing and Commissioning of AHRI/Eurovent certified Rotary Screw Air cooled Chilling M/C of 80 TR actual capacity at tender operating conditions (as mentioned below) with R - 134a refrigerant (ozone friendly, HFC) ar any other refrigerant as per NBC 2016 norms meeting all functional requirements and approved by E-I-C, semihermatic / hermetically sealed single /multiple compressors with mono/twin screw complete with single/multi refrigerant circuit, driven by suitable KW Squirrel Cage induction motor complete with insulated shell and tube flooded chiller, with S.S braided pipe flexible connector, insulation to be mechanically protected similar to chilled GLYCOL piping insulation, flanged end for chiller & condenser, electronic auto setting GLYCOL flow switches at chiller outlet, factory done refrigerant piping, refrigerant and oil first charged, microprocessor based control panel , motor drive by floor mounted air-cooled VSD/VFD with IP54 or better as per OEM standards enclosure , factory installed electrical disconnect / isolator switch integrating main fuses etc. all mounted on M.S. frame. Motor shall be suitable for 415 volts ± 10%, 50Hz ± 5 %, three phase A.C. supply, class F insulation & IE -3 rated. Chillers shall be provided with spring isolators. The Condenser Fan control shall be provided with VFD.It should include flow switch/DP switch at chiller and condenser, vibration isolators, including oil separators, pressure relief devices, filter drier moisture indicators, refrigerant economizer, integral refrigerant piping and wiring, accessories as required and called for, automatic and safety controls mounted in central console panel.dB Level shall not be more than 82 @ 1.5 m or as per relevant norms. The unit will be with compressor accoustic jacketing for noise/vibration reduction. Cost for Suitable PCC/RCC foundation ( PCC foundation in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate 30 cm above floor level including making connection of inlet & outlet with fittings including nut, bolts, packing etc.) with plaster is deemed to be included in this item cost along with spring isolators. The cost of chilling machine shall be inclusive of BMS interface card for integration with BMS System & any deration in capacity to be accounted in arriving at the actual capacity of chiller including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Chiller GLYCOL in : -13o C /8.6F GLYCOL out : -15o C/5F GLYCOL flow rate: 540 USGPM (min.) Chillers complete in all respect - (2W+1S)
Primary Chilled GLYCOL Pumps Set Supply, installation, testing and commissioning of vertical Inline Pump/ Vertical/Horizontal split casing , back pull out flexible coupled End Suction Pump mounted on a common base with electric motor for re-circulation of GLYCOL for the central air conditioning system. The pumps shall be flexible coupled protected by OSHA complaint coupling guard, with CI casing, SS (CF8) /bronze impeller, high strength steel shaft (prefarably SS 304) and MS fabricated base plate .The pump motor shall be suitable for 415± 10% volts, 50 cycles, 3 phase AC power supply of (IE3) efficiency class. Motor shall be squirrelcage with Class F insulation, 1500 RPM(Max.) Pump, base, coupling and motor shall be factory assembled. The capacity of motor shall be at least 10% in excess of BHP requirement of pump. The internal components of pumps including mechanical seal shall be suitable to sustain a temperature of 122 degree Fahrenheit. Minimum efficiency of pump shall be as mentioned below. Cost for pump foundation, suitable support/Mounting Arrangement including making connection of inlet & outlet with fittings including nut, bolts, packing etc.)withplaster, Antivibration arrangement of cushy footmountigs is deemed to be included in this item cost. Suction guide to be provided by pump manufacturar for unit responsability. Pump curves & loss calculations shall be furnished during approval from competant authority. Pumps shall be BMS compatible. Pump rating shall be PN 16 preferably. Contractor to submit proposed pump model with duty curve. The entire work shall be complete as per specifications & as per directions of Engineer-in-charge. flow rate : 540 USGPM Head : 50ft./16m Motor HP :10HP (suggested) or as per OEM standard & meeting the functional requirements Efficiency(Min) : 75 % or nearest as per OEM Pumps complete in all respect (2 working+1 standby ) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Secondary Chilled GLYCOL Pumps Set With VFD for ice rink Supply, installation, testing and commissioning of Vertical Inline Pump/Vertical/Horizontal split casing , back pull out flexible coupled End Suction Pump mounted on a common base with electric motor for re-circulation of GLYCOL for the central air conditioning system. The pumps shall be flexible coupled protected by OSHA complaint coupling guard, with CI casing, SS (CF8)/bronze impeller, high strength steel shaft (prefarably SS304) and MSfabricated baseplate.The pump motor shall be suitable for415±10% volts,50 cycles,3 phase AC power supply of (IE3 ) efficiency class. Motor shall be squirrelcage, Class Finsulation,1500RPM (Max.). Pump, base, coupling and motor shall be factory assembled. adjustable & compleet in all resepct as per directions of E-I-C. The capacity of motor shall be at least 10% in excess of BHP requirement of pump. The internal components of pumps including mechanical seal shall be suitable to sustain a temperature of 122 degree Fahrenheit. Minimum efficiency of pump shall be as mentioned below. Cost for pump foundation, suitable support/Mounting Arrangement including making connection of inlet & outlet with fittings including nut, bolts, packing etc.) with plaster. Pumps Shall be BMS & VFD compatible. Suction guide to be provided by pump manufacturar for unit responsability. Contractor tosubmit proposed pump model with duty curve. Pump rating shall be PN 16 The entire work shall be complete as per specifications & as per directions of Engineer-in-charge. The chilled GLYCOL pumps shall also includethe cost of thermal insulation. Secondary chilled water pumps shallbe suitable for operation on variable frequency drives & conforming tothespecifications of variable speed pumpingsystem. The capacity of motor shall be at least 10% in excess of BHP requirement of pump. Secondary Chilled GLYCOL pump including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Secondary Chilled GLYCOL pump flow rate : 540 USGPM Head : 115 ft./35m Motor HP :18 HP (suggested) or as per OEM standard or meeting functional requirements Efficiency : 75 % or nearest as per OEM Pumps complete in all respect (2working+1 standby )
Variable Speed Pumping System controller for Secondary Pump Supply, installation, testing and commissioning of separate Primary Variable pump controller with IP55 Protection, sensorless/wireless control for the redundancy of VSPS (variable Speed Pumping System). The controller should stage or destage the pumps based on BEP(Best Efficiency Point) for the optimum efficiency of variable speed pumping system. Controller should be BMS compatible for Modbus/Bacnet connectivity. Minimum 2 Nos of wireless sensors should be considered for each zone. All variable pumps shall have remote monitoring facility to connect data to cloud server for active performance management and real-time alerts for analysis and early diagnostic messaging and real time trends. It should be complete as per manufacturer's Specifications & as directed by Engineer-in-charge. For 3No. of 18 H.P Secondary Chilled Pumps (2W+1 S) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Closed Type Pressurized Expansion Tank (Chilled Water Line) Supply, installation, testing and commissioning of closed expansion tank system. Tank will be of M.S. construction with interchangeable EPDM-BUTYL rubber membrane. The expansion tank shall be complete with safety relief valve and pressure gauge. The tank will be of pressure rating to suit the system pressure and will be sized to adequately compensate for water expansion due to operating temperature variations.the tank shall be fabricated as per ASME and must be ASME stamped for 250 PSIG operating pressure. For chilled water application, it will be insulated with 50 mm thick insulation to the specifications and cladded with 26G-aluminum cladding. The capacity of tank shall be 500 Liters including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supply, installation, testing and commissioning of pressurisation unit shall be with 2 nos. (1 working + 1 stand by) vertical multi-stage pumps of suitable rating & capacity, as indicated hereunder, factory mounted on a steel frame along with interconnected piping, valves, strainer, pressure gauge, pressure transmitter, flow meter to measure the make-up water quantity, control panel with duty cycling and dry-run protection, electrical relays/contactors and interconnecting wiring:The unit shall be capable of Pressurising the system to the required pressure with suction from a break-tank located at least 1m above pump level including carriage of material in all lead and lift as per direction of Engineer-in-Charge. Flow 2CMH (60mwc)
Sub Head 'B' - PIPING INSULATED CHILLER PIPING Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
200 mm dia. (32 mm thick insulation)
150 mm dia.(32 mm thick insulation)
INUSLATED VALVE Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Butter fly Valve(Manual) with CI body SS Disc,Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot water circulation as specified. 150 mm dia Lever Type including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Balancing Valve with built in measuring facility with CI body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. 150 mm dia including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Non Return Valve with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified. It shall be of wafer type preferably with flanged ends. It should be tested for required hydrostatic pressure for shell & seat as per OEM & shall be suitable for maximum working temperature of 80 degree C (approx.). 150 mm dia including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Y-Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specified. 150 mm dia including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing and fixing in position the industrialty pepressure gauges with gunmetal / brass valves complete as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Providing & Fixing in position the mercury in glass with industrial type thermometers.
Providing, fixing, testing & commissioning of resilient rubber lined double arch vibration eliminator expansion bellow suitable for raw water up to 45 deg. C temperature to provide relief from stresses at pipe flanges. It should be complete as per manufacturer's specifications & as directed by Engineer- in-charge.(PN 16 rating) including carriage of material in all lead and lift as per direction of Engineer-in-Charge. 150 mm dia
Providing and fixing in position the following water flow switch as per specifications:
REFRIGERATION PIPING Supply installation testing & commissioning of Portable Ice Rink Refrigeration Pipe Grid Material: Virgin High Density Polyethylene Elongation: 395% Operating Temperature: - 40°C to 65.6°C Durometer: (shore A), 94 Tensile Strength: 4,298 psi Heat Transfer Efficiency: 127% (Ice Rink Area to Pipe Surface Area) Pipe Spacing: 1” (Center to Center) Diameter: 1/2” (O.D.), 1.5mm Thick Total Number of Pipes (Side Header System): 2180 pipes Design: Pipe Cut based on ice rink shape Hose Barbs: None Connectors: Full Flow, Push Fit Connectors and Multi-Seal Technology Pipe Chairs: Virgin High Density Polyethylene, Custom Made, 1 ft. Spacing including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supply installation testing & commissioning of Portable, Reverse-Return Header (Side Header) Material: Sch. 80 Polyvinyl Chloride Diameter: 6” Standard: ASTM D1785 Design: Pre-Fabricated with Custom-Groove for Victaulic Coupling Mount. Thread: 1/2” NPTF, 48 Holes Length: 4ft. (End to End) including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supply installation testing & commissioning of Refrigerant Transmission Pipe System Material: Sch. 80 Polyvinyl Chloride Diameter: 6” Standard: ASTM D1785 Design: Pre-Fabricated with Custom-Groove for Victaulic Coupling Mount. Standard Length: 20ft. (End to End) Pressure Gauge: 100 to 300 PSI Range (Reading) mounted to the Pipe with Isolation Valves Isolation Valves: Standard Butterfly Valve for 6" Diameter Flow Meter: Standard Device up to 1500 Gallons/Minute reading including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Sub Head 'C' - MISC. Supply installation testing & commissioning of Propylene Glycol Generic Name: Inhibited Propylene Glycol including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supply installation testing & commissioning of Ice Building Equipment, Maintenance Tools and Ice Paint, to install your first ice sheet All the tools needed to professionally install and maintain your ice sheet. Three (3) ice product mixing tubs, a 1.5 Hp electric pump, a patented ice building two (2) nozzle set, a 19mm make-up water hose, a stirring paddle, three (3) 19 liter pails, and a 25.4mm diameter applicator hose (the length of your rink) are included. Supply the following ice maintenance tools; a. Ice Chipper: This heavy-duty tool is a must for chipping away any unwanted ice buildup, as around doors. b. Ice Scraper: This stainless steel tool is used to shave off the ice unwanted items (like split ice paint or blood paint). c. Rink Squeegee: with a true radius design makes this push squeegee the best in the market for clearing your ice of excess water, like around the resurfacer gate. d. Hand Snow Plow: a 48” (1.2 m) wide and is used to push, from the ice, the “snow droppings” from the ice resurfacer at the equipment gate. In the event of a break down of the ice resurfacer, several Hand Snow Plows can quickly clear the rink of snow, so order several plows. e. Snow Scoop: a large mouth, heavy duty, high impact, and easily scoops up the “snow droppings” from the ice, left by the resurfacer at the equipment gate. This heavy duty snow scoop offers years of service as it will not bend or corrode including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Supply installation testing & commissioning of Ice Making Products: a.) Instant Ice: is blended into water to create a slurry of slush, which is used to seal the porous sand rink floor with an instant ice glaze. b.) Slush Ice: is added to water to fom a room temperature slush. When installing the initial ice sheet it seals the seam where the boards meet the rink floor. During the season it is used to repair cracks and divots in the ice. c.) Ice Building Additive: is a liquid concentrate, which is added to the cold ice building water when installing the initial ice sheet each season. Hot water for building is eliminated because IBA reduces the tendency of the water to produce ridges when building ice. With IBA the cold treated water flows evenly across the ice for a smooth ice surface. IBA also allows entrapped air to escape from the ice building water thus creating a denser ice sheet. This denser ice is more energy efficient, all season long. d.) Base Ice: This powder is added to water to form a thickend ice solution which is sprayed onto the rink floor to opaque out (white over) the dark color of the rink floor with layers of white ice. The Base Ice secret is the use of only titanium dioxide crystals, as the pigment; this provides the whitest ice available. Our competition uses “clay extenders” and cheap pigments in their old fashioned ice paints. Their cheap paint allows heat to be absorbed by the ice...your chiller must run more to remove that heat. e.) Slick Ice: A liquid concentrate that is mixed with cold resurfacing water and eliminates costly hot water ice resurfacing. W hy would you want to spread “liquid heat” on top of your ice'7 This unique, internationally patented, product not only saves energy but also provides an improved, shiny, and faster ice surface. Slick Ice resurfacing cuts down on the fogging of the rink air. The first month supply of Slick Ice is included; additional is available at retail fee including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
5d. Electric Ice Edger Features: - Additional safety guard surrounds cutting disk - Ability to cut flat or on an angle with the ice surface - Eight (8) easy to replace long lasting cutters - Smart charging system - Large rear wheels and smaller front wheels for easy off ice transport - Ultra quiet wander free operation - 12V maintenance free batteries mounted over wheels for Ideal weight distribution - Powerful 24V 2.0 kW 3200 RPM electric motor - Cutting width of 14” 356mm - Snow is always directed toward center of ice, away from the boards and operator - Fully adjustable board guide to help eliminate chipping - Hot dipped galvanized steel body with stainless steel parts for corrosion protection - Weight: 113kg including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
5e. Skate Sharpening Machine Features: - Weight - 85 lbs - Dimension - 24 x 20 x 12 in - Composed with Single Phase Asynchronous Motor - Can be Mounted on any Flat Surface
SITC of composting machine of organic waste system of 50KG per day, Machine Size (L x W x H) in meter : 2.35 x 0.93 x 1.68, Power : 8 HP, Waste Treatment Capacity : Up to 50 kg/day, All Wetted Parts : Stainless Steel SS 304, Operation : Fully Automatic., Volume Reduction : Up to 80-90%., Shredder : Built-in, Power requirement Three phase 415 V, 63 A connections with earthing and neutral, as per technical specification including civil works of required shed and foundation base (Smartenviro/Excel/Tanco or equivalent or as per the direction of site engineer including all leads and lifts.
Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required including carriage of material in all lead and lift as per direction of Engineer-in-Charge.
Provisional Sum The comparison of bid shall be done exclusive of provisional sum.The cost shall include cost of Environmental testing etc. A handling fee of 5% (Five Percent) shall be payable to contractor to actual cost of any approve expenditure under as Provitional Sum Items 1 Job 500000
SUNEHARI BAGH BUILDERS PVT. LTD. (BID ID -436285)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid