| 1 | L1₹29.2 LAccepted-AOC NO 133 RASHTRAPATHI ROAD SECUNDERABAD 500 003 | SECUNDERABAD | HYDERABAD | TELANGANA | 500003 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.9 L+₹4.6 L (14.5%)Rejected-AOC PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L2 | Rejected-AOC Not Being L1 | |
| 3 | L3₹36.9 L+₹5.5 L (17.6%)Rejected-AOC | L3 | Rejected-AOC Not Being L1 | |
| 4 | L4₹37.9 L+₹6.5 L (20.8%)Rejected-AOC | L4 | Rejected-AOC Not Being L1 | |
| 5 | L5₹38.2 L+₹6.8 L (21.7%)Rejected-AOC DOOR NO 57 28 10 4 2 BHAVANI GARDENS INDUSTRIAL ESTATE POST VISAKHAPATNAM 530 007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L5 | Rejected-AOC Not Being L1 |
| Sl No | Description | Qty | Unit | Sri Balaji Enterprises L4 | Universal refrigeration and Engineering Company L2 | SUN LIGHT HOUSE L6 | M/S P UDAY RAJ CONSTRUCTION L7 | B SRINIVAS L5 | SVG SUPPLIES L8 | THE DECAN ENGINEERING AND REFRIGERATION COMPANY L1 | SRI SAI RAM ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down existing unserviceable point wiring of any description/type/ size of light/fan/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site area and making good the disturbed surfaces of wall/ceiling all as specified & directed by Engr in Charge. | 650 | Point | 5 ₹3,250 Lowest | 5 ₹3,250 Lowest | 10 ₹6,500 | 10 ₹6,500 | 5 ₹3,250 Lowest | 5 ₹3,250 Lowest | 5 ₹3,250 Lowest | 10 ₹6,500 |
| 2.00 | Disconnecting and removing the MCB DBs/AC Box from any height, stripping out the fitting for examine replacement of US spare parts, reassembling, refixing in original position including minor repairs for the smooth functioning and testing complete all as specified & directed by Engg in Charge. | 42 | Each | 10 ₹420 | 10 ₹420 | 5 ₹210 Lowest | 10 ₹420 | 10 ₹420 | 10 ₹420 | 5 ₹210 Lowest | 10 ₹420 |
| 3.00 | Taking down old submain wiring of any size and type complete all as specified and directed by Engr in Charge. | 430 | RM | 15 ₹6,450 | 5 ₹2,150 | 5 ₹2,150 | 10 ₹4,300 | 3 ₹1,290 Lowest | 10 ₹4,300 | 5 ₹2,150 | 10 ₹4,300 |
| 4.00 | M&L Surface point wiring for any length with 1100 volts grade 1.5 sqmm PVC insulated FRLS unsheathed cable with multistrandard copper conductor with ISI marking and including non-metallic PVC casing caping medium grade of size minimum 20 mm with all accessories in wall/ceiling including continuous earth wire 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes concealed in wall and modular white plate covers with frame for mounting of modular switches/sockets/fan regulators etc,for one light/fan point controlled by one switch complete all as specified and directed. Note : Wiring from the DB (distribution box) to switch and sunken modular flush sheet metal enclosures and modular cover plates shall be deemed inclusive in the quoted rate. | 480 | Point | 620 ₹2,97,600 | 590 ₹2,83,200 | 500 ₹2,40,000 Lowest | 550 ₹2,64,000 | 600 ₹2,88,000 | 550 ₹2,64,000 | 500 ₹2,40,000 Lowest | 625 ₹3,00,000 |
| 5.00 | All as per Item No. 4 above, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board . | 70 | Point | 620 ₹43,400 | 580 ₹40,600 | 500 ₹35,000 Lowest | 520 ₹36,400 | 600 ₹42,000 | 550 ₹38,500 | 500 ₹35,000 Lowest | 625 ₹43,750 |
| 6.00 | All as per Item No. 4 above, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board. | 60 | Point | 210 ₹12,600 | 175 ₹10,500 | 200 ₹12,000 | 175 ₹10,500 | 180 ₹10,800 | 60 ₹3,600 Lowest | 200 ₹12,000 | 180 ₹10,800 |
| 7.00 | All as per Item No. 4 above, but for using 2.5 Sqmm single core copper conductor cable of multistranded PVC insulated sheathed FRLS 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 2.5 Sq mm FRLS copper conductor PVC insulated cable as earth continuity conductor | 40 | Point | 680 ₹27,200 | 640 ₹25,600 | 700 ₹28,000 | 725 ₹29,000 | 685 ₹27,400 | 600 ₹24,000 Lowest | 650 ₹26,000 | 750 ₹30,000 |
| 8.00 | S & F Modular switch 1 way 6/10 Amps, 1 Module complete all as specified and directed. | 710 | Each | 55 ₹39,050 | 40 ₹28,400 | 38 ₹26,980 | 40 ₹28,400 | 38 ₹26,980 | 22 ₹15,620 Lowest | 40 ₹28,400 | 55 ₹39,050 |
| 9.00 | S & F Modular switch 1 way 16/20 Amps, 1 Module complete all as specified and directed. | 90 | Each | 85 ₹7,650 | 90 ₹8,100 | 49 ₹4,410 | 60 ₹5,400 | 43 ₹3,870 Lowest | 80 ₹7,200 | 60 ₹5,400 | 120 ₹10,800 |
| 10.00 | S&F Modular Bell Push 10A, 1 Module complete all as specified and directed. | 40 | Each | 85 ₹3,400 | 60 ₹2,400 | 50 ₹2,000 | 52 ₹2,080 | 45 ₹1,800 Lowest | 60 ₹2,400 | 60 ₹2,400 | 120 ₹4,800 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
16 Jan 2026, 6:00 pmClosed
Shri Rajesh Kumar Meena, GE
Garrison Engineer North 35 Allenby Lines Secunderabad 500087
REPAIRS REPLACEMENT OF CONVENTIONAL LIGHT FITTINGS WITH ENERGY SAVING LED LIGHT FITTINGS AT BOLARUM AREA UNDER AGE EM N OF GE (NORTH) SECUNDERABAD
2025_MES_746103_1
8997
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
GARRISON ENGINEER NORTH SECUNDERABAD
As per Tender Documents
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER NORTH SECUNDERABAD
₹96,000
Yes
23 Feb 2026
26 Dec 2025
23 Jan 2026
26 Dec 2025
16 Jan 2026
9 Jan 2026
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site area and making good the disturbed surfaces of wall/ceiling all as specified & directed by Engr in Charge.
Disconnecting and removing the MCB DBs/AC Box from any height, stripping out the fitting for examine replacement of US spare parts, reassembling, refixing in original position including minor repairs for the smooth functioning and testing complete all as specified & directed by Engg in Charge.
Taking down old submain wiring of any size and type complete all as specified and directed by Engr in Charge.
M&L Surface point wiring for any length with 1100 volts grade 1.5 sqmm PVC insulated FRLS unsheathed cable with multistrandard copper conductor with ISI marking and including non-metallic PVC casing caping medium grade of size minimum 20 mm with all accessories in wall/ceiling including continuous earth wire 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes concealed in wall and modular white plate covers with frame for mounting of modular switches/sockets/fan regulators etc,for one light/fan point controlled by one switch complete all as specified and directed. Note : Wiring from the DB (distribution box) to switch and sunken modular flush sheet metal enclosures and modular cover plates shall be deemed inclusive in the quoted rate.
All as per Item No. 4 above, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per Item No. 4 above, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per Item No. 4 above, but for using 2.5 Sqmm single core copper conductor cable of multistranded PVC insulated sheathed FRLS 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 2.5 Sq mm FRLS copper conductor PVC insulated cable as earth continuity conductor
S & F Modular switch 1 way 6/10 Amps, 1 Module complete all as specified and directed.
S & F Modular switch 1 way 16/20 Amps, 1 Module complete all as specified and directed.
S&F Modular Bell Push 10A, 1 Module complete all as specified and directed.
S&F Socket outlet modular type multipurpose 2/3 Pin, 6 amps, 230 volts combined 2 Module complete all as specified and directed.
S&F Socket outlet modular type multipurpose 2/3 Pin, 6/16 amps, 230 volts combined 2 Module complete all as specified and directed.
S & F Modular ceiling fan regulator stepped type heavy duty suitable to work on 230 volts, 2 Module complete all as specified and directed.
S&F Bell ding dong working on 230 volts AC Supply complete all as specified and directed.
S & F Angle holder insulated body surface bakelite with back plate suitable for angle / batten fittings complete all as specified and directed.
S & F Ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and directed.
S&F in replacement recess mounting with perforated sheet with electronic driver luminaire 36 watts LED slim panel (2'x2'), 6500K with central opal diffuser series mounted in grid ceiling surfaces and suitable hanging provision where required including all accessories with new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed.
S&F in replacement recess mounting with perforated sheet with electronic driver luminaire 36 watts LED slim panel (2'x2'), 3000K with central opal diffuser series mounted in grid ceiling surfaces and suitable hanging provision where required including all accessories with new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed.
S&F in replacement of Wall mounted LED Batten, extruded powder coated aluminum housing heat sink provided for efficient heat dissipation & integrated electronic driver 1x12W,6500 K, 230 Volts, diffused type connector block, internally pre wired etc including new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and directed.
S & F 9 W LED lamp,6500 K suitable for angle and batten holder complete all as specified and directed by Engg in charge.
⁓…⁆‹⁗䕌⁄慬灭㌬〰‰⁋畳瑩扡敬映牯愠杮敬愠摮戠
Supply and fix in replacement of MCB SP 6 to 32 Amps 240 volts, 'B' curve for fixing on MCB DB's complete all as specified and directed.
S & F in replacement of MCB SPN 40 to 63 Amps 240 'C' curve 240 volts for fixing on MCB DB's complete all as specified and as directed.
S & F Sheet metal enclosure MCB DB SPN 8 way with 200 amps rated bus bar 240 volts double door with locking system complete all as specified
M&L Earthing with galvanized mild steel earth plate electrode 60 centimetre x 60 centimetre x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level, the top edge of the earth plate at a depth of not less than 1.5 metres below ground level connected to galvanized iron earth wire of 4 mm dia by means of bolts, nuts and washers made out of GI / steel earth wire protected by GI light grade pipe 15 mm bore, 20mm dia light grade galvanised iron pipe with funnel wire mesh for watering and connecting to main switch board / control board all s shown in electrical plate of SSR Pt - I connected to earthing test point and including testing on completion complete all as specified and as directed. Note: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 type C1 by using 20 mm graded aggregate in pit, 50 mm thick reinforced cement concrete 1:2:4 type B1 using 20 mm graded aggregate cover duly reinforced with 8 mm dia TMT bars @ 100mm centre to centre both ways, CI cover with CI frame hinges, galvanised iron funnel with watering pipe, wire mesh, complete.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
8997TENDER.pdf
Tender Documents • 1.12 MB
BOQ_835446.xls
BOQ • 0.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .