Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹26.2 LAccepted-AOC | 1 | Accepted-AOC AWARDED BEING THE LOWEST TENDERER | |
| 2 | 2₹29.0 L+₹2.7 L (10.2%)Rejected-Finance FLAT NO 202 GANGOTRI PARADISE VINAYAKA NAGAR VUDA COLONY GAJUWAKA VISAKHAPATNAM 530 004 | VISAKHAPATANAM | ANDHRA PRADESH | 530004 | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | Rejected-Technical | - | Rejected-Technical VERIFIED AND NOT ADMITTED MOU NOT SUBMITTED | |
| 4 | Rejected-Technical | - | Rejected-Technical VERIFIED AND NOT ADMITTED MOU NOT SUBMITTED |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
1 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER NAVAL BASE VISAKHAPATNAM
GARRISON ENGINEER NAVAL BASE GANDHIGRAM POST VISAKHAPATNAM 530005
PERIODICAL SERVICES TO BUILDINGS AT INHS KALYANI, SHO AND NCS INCLUDING REPAIRS TO CHAJJAS, DROPS, PARAPETS UNDER AGE BR-II OF GE (NB) VISAKHAPATNAM
2023_MES_592603_2
C/8178/23-24/E8 / Token 29 of 2023-24
Open Tender
Civil Works
Item Rate
270 days
VISAKHAPATNAM
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER NAVAL BASE
₹60,000
Yes
18 Aug 2023
10 Jun 2023
3 Jul 2023
10 Jun 2023
1 Jul 2023
17 Jun 2023
Amount
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing rubbish to outside MD land complete all as specified and directed
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 5 mm thick in cement mortor 1:3 on concrete surfaces as in ceilings and finishing surfaces even and fair without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
Demolition of reinforced cement concrete in any position not otherwise specifically provided for and removing rubbish to outside MD land complete all as specified and directed.
M & L for use & waste Form work to chajjas, troughs and similar items including edges flat for rough finished surfaces of concrete complete all as specified and directed.
M & L for use & waste Form work to fins, louvers, fascia, parapets etc for rough finished surfaces of concrete complete all as specified and directed.
M & L for use & waste Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizonal or sloping) for flat rough finished surfaces of concrete complete all as specified and directed.
M & L Reinforced Cement Concrete 1:1.5:3, Type A-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in chajjas etc complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
M & L for RCC 1:1.5:3, type A-1 (Using 20 mm graded stone aggregate) as in Fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the like complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
M & L for Reinforced Cement Concrete 1:1.5:3, Type A-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, shelves etc complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
S & F high strength corrosion resistant TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
S & F high strength corrosion resistant TMT steel bars 6mm to 8mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved Bonding Agent / Epoxy Treatment in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 25mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 duly modifying the mortar with and including suitable bonding agent of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 5% of weight of cement for sides and soffits of Slabs, Beams, Columns, Fins, Parapets Facias & Chajjas etc., finishing the top surface even and smooth without using extra cement conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of MD land complete all as specified and as directed.
M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved Bonding Agent / Epoxy Treatment in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 30mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 duly modifying the mortar with and including suitable bonding agent of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 5% of weight of cement for sides and soffits of Slabs, Beams, Columns, Fins, Parapets Facias & Chajjas etc., finishing the top surface even and smooth without using extra cement conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of MD land complete all as specified and as directed.
M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved Bonding Agent / Epoxy Treatment in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 40mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 duly modifying the mortar with and including suitable bonding agent of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 5% of weight of cement for sides and soffits of Slabs, Beams, Columns, Fins, Parapets Facias & Chajjas etc., finishing the top surface even and smooth without using extra cement conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of MD land complete all as specified and as directed.
S & F in repairs 0.71mm thick Plain Aluminium sheeting Alloy 31000 H4 in stepped flashing (measured as the minimum rectangle from which the pieces can be cut) complete all as specified and directed.
M & L Removing loose material from existing crumple joints and Preparing the Groove with "NITO BOND SBR" mixed in Cement and Mortar 02 Ltrs per Bag of Cement, grove size of 25 mm X 10 mm, including filling with poly supplied sealant "THIOFLEX 600" two part component of Fosroc Chemicals or equivelant of make Dr. Fix it / Araldite as per list of manufacturer's complete all as specified and as directed.
M & L for Complete removal of existing treatment from walls/ceiling etc by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7/9 inch to make the surfaces free from dust, loose paints etc by skilled labour complete all as specified and directed.
M & L for applying water proof cement based putty @ 1Kg (undiluted)/Sqm of average thickness 1mm over the plastered/old painted wall/ceiling etc after scrapping to prepare the surfaces even and smooth and sanding the putty surfaces with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surfaces free from dus etc by skilled labour as per the following steps complete all as specified and directed: (a) Step 1: Mix the putty powder by adding water as per the manufacturer's instructions and mix it with putty mixer of mixing capacity of min 2.5 Kg putty per minute. (b) Step 2: Apply the first coat of prepared mixer with the help of fully automatic airless spray machine of putty application having glow speed of max 6 ltrs per minute with a maximum pressure 3300 PSI (c) Step 3: Allow 6-8 hrs time to dry the putty surfaces
M & L for applying one coat of acrylic water based interior grade primer @ 0.8 ltr (undiluted)/ 10 Sqm diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with flow speed of min 1 ltr per minute having a pressure of 3300 PSI and allow 6-8 hrs to dry the surfaces for painting of susequent coat complete all as specified and directed.
M & L for applying two coats of oil bound distemper by using fully automatic Airless spray tenchnology machine with max pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr, the spray machine should be from reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and acccessories for applying distemper in hard to reach areas and penetration of distemper on the surface complete all as specified and directed. (Note: Sanding of surfaces shall be done by mechanical sander with 1500-2700 rpm with internal dust extraction system for clean environment certified by the Paint manufacturer)
M & L for preparing old decorated surfaces of wall including cornices, pilasters etc, including bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying one coat of distemper by using Airless spray technology machine with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr, the spray machine should be from reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and acccessories for applying distemper in hard to reach areas and penetration of distemper on the surface complete all as specified and directed. (Note: Sanding of surfaces shall be done by mechanical sander with 1500-2700 rpm with internal dust extraction system for clean environment certified by the Paint manufacturer)
All as per Serial item No. 24 above but to ceiling surfaces complete ditto
M & L for applying one coat of acrylic water based exterior grade primer @ 0.9 Ltr (undiluted)/10 Sqm diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 Ltr per minute having presure of 3300 PSI and allow 6-8 hrs to dry the surfaces for painting of subsequent coats complete all as specified and directed.
M & L for applying Two coats of of water based 100% Premium acrylic smooth exterior emulsion paint with silicon aditive and colour stay technology, excellent Dirt Pick up resistance with low VOC less than 50 gm/litre as per the LEEDS specifications and UV resistance as per IS 15489:2004, Alkali & fungal resistance of required shade (Company Depot Tinted) @ 1.79 Ltr (undiluted)/10 Sqm for two coats diluted with water as per manufacturer instructions with fully automatic airless spray machine of paint application with a flow speed of min 1 Ltr per minute having presure of 3300 PSI and allow 6-8 hrs to dry the surfaces in both the coats of paint complete all as specified and directed.
M & L for preparation old decorated external surfaces of wall, chajja, facia, ceiling parapet etc including cornices, pilasters etc including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss, effloresecnt salts, trading oil, greasy spots and applying one coat of water based 100% Premium acrylic smooth exterior emulsion paint with silicon aditive and colour stay technology, excellent Dirt Pick up resistance with low VOC less than 50 gm/litre as per the LEEDS specifications and UV resistance as per IS 15489:2004, Alkali & fungal resistance of required shade (Company Depot Tinted) @ 0.90 Ltr (undiluted)/10 Sqm diluted with water as per manufacturer instructions by using Airless spray technology machine with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr, the spray machine should be from reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and acccessories for applying paint in hard to reach areas and penetration of paint on the surface complete all as specified and directed.
M & L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M & L for preparing old decorated surfaces of walls including cornices, pilasters etc by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying one coat of white wash complete all as specified and directed.
M & L for preparing old decorated surfaces of ceiling including cornices, pilasters etc by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying one coat of white wash complete all as specified and directed.
M & L for preparing old decorated surfaces of wall/ceiling, including cornices, pilaster etc by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying one coat of smooth interior acrylic Plastic emulsion paint with rich matt finish having VOC less than 50 Grms per ltr complying LEEDS criteria @ 1 ltr (undiluted)/ 10 Sqm diluted with water in 2:1 ratio as per manufacturer's instructions by using Airless spray technology machine with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr, the spray machine should be from reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and acccessories for applying paint in hard to reach areas and penetration of paint on the surface complete all as specified and directed. complete all as specified and directed. (Note: Sanding of surfaces shall be done by mechanical sander with 1500-2700 rpm with internal dust extraction system for clean environment certified by the Paint manufacturer)
M & L for Preparation of old painted wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for Preparation of old painted wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed.
M & L for Preparation of old painted steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint complete all as specified and directed.
M & L for Preparation of old painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed.
M & L for Obliterating old writing of any description, n exc 0.1 sq. m, with paint to match existing work with synthetic enamel paint complete all as specified and directed.
M & L for Writing letters or figures (Block ,Roman, Italic or Indian) n. exc 30 cm height with synthetic enamel paint complete all as specified and directed.
M & L for Writing stops, commas, short lines , dashes, hyphens, brackets, etc with synthetic enamel paint complete all as specified and directed.
Demolition of cement concrete (unreinforced) in any position not otherwise specifically provided for as in roof padding etc including old detoriated roof treatment and bedding layer and removing debries and rubbish to a distance outside MD land complete all as specifed and directed.
M & L for 10 mm thick screed bed in CM 1:4 mixed with WPC as per manufacturer's instructions over 25 mm thick PCC 1:2:4 type B-0 (12.5mm graded aggregate), as in levellig course, Supply and lay polymeric water proofing membrane of weight 3kg/sq.m incorporating a centre core of 90 micron thick HMHDPE film including coating the surface with a coat of water based bituminous primer @ 100gms/sq.m., followed by a coat of blown bitumen of grade 85/25 or 90/15 @ 1.2kg/sq.m. each at top and bottom of the membrane including sealing all joints by thermo fusion with minium 10cm overlap incl grooving & inserting in parapt wall all as per manufacturers instructions complete all as specified and as directed. (Note: WPC shall be measured and paid seperately)
M & L for cement concrete tiles of size 25cm x 25cm x 22mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished, including 15 mm thick screed bed in cement mortar 1:6 and set & jointed in neat cement slurry and pointed in with mixture of white and grey cement equal proportion and no pigment complete all as specified and directed.
Complete removing the plants from the surfaces of the building with complete roots, applying recommended chemical to prevent further growth as directed, making good the disturbed surface with cement mortar 1:3 and applying the same surface finish of the existing surface and finished to match with the surrounding surfaces including removal of debris etc., out side the premises complete all as required complete all as specified and as directed.
RAVITEJA ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .