Tender Value
₹15.2 L
EMD Value
₹30,500
Closing Date
5 Oct 2026, 4:00 pm
Ex Engineer ED Ganderbal
Office of the Ex Engineer ED Ganderbal
Providing of 3 phase HT power supply to newly constructed 500 KLD and One 200 KLD Capacity Modular Sewerage Treatment Plant based on MBBR Technology at Sonamarg under Sewerage Scheme phase-1st
2026_PDD_324709_1
EDG/V/082 OF 2026-27
Open Tender
Electrical Works
Lump-sum
20 days
GANDERBAL
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
Ex Engineer ED Ganderbal
₹30,500
15 Sept 2026
15 Sept 2026
6 Oct 2026
15 Sept 2026
5 Oct 2026
15 Sept 2026
15 Sept 2026 - 16 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Supply,installation, testing and commissioning of 11 kV, 1 core(4 runs) 185sq.mm, Al conductor,XLPE, insulated, armoured cable (from the RMU to the transformer) | 600 | Mtrs | - | - |
| 1.02 | Providing and Fixing of 11 kV, Ring Main Unit ,SF6 Insulated, out-door type, Extensible type,breaking capacity 25 kA for one second with SF6 circuit breaker / VCB self powered with O/C + E/F Relay comprising of
a) 11kV 630 Amp Motorised isolator including earthing Switches with making capacity 52kA, having mechanical ON/OFF, earth indications with fault current Indicator.
b) 11kV ,200 Amp motorised Spring operated, Circuit breakers with earthing switches, connecting the RMU to Supply transformer.
c).Copper Bus Bar of 630 Amp rating.
d). 1 No Numerical Aux. Powered relay having non directional O/C and E/F protection (for each ciruit breaker).
d). The Circuit Breaker enclosures shall be outfitted with a communicable-type numerical (feeder protection) relay, i.e., one for each circuit breaker. The relay shall also interface via an RS 485 port in order to send, as a minimum, real-time phase current , readings using the MODBUS protocol.
e) Incomming Isolator having FPI with eclectrical reset Contact/facility.
f) All necessary Potential free contacts for indications relevent to RMU monitoring and control .
g) Capacitor voltage dividers serving Live-Line Cable indicators in each breaker and Isolator. | 1 | No | - | - |
| 1.03 | Providing and Fixing of 11kV 1 core indoor terminating kit to be used with cables- 185sq.mm. | 8 | No. | - | - |
| 1.04 | Providing and Fixing of 11kV 1 core outdoor terminating kit to be used with cables - 185 sq.mm. | 8 | No. | - | - |
| 1.05 | Providing and fixing of Route Marker as per REC Standard. | 6 | No. | - | - |
| 1.06 | Providing and Excavation in any type of soil including hard laterite soil. | 23.29 | Cum | - | - |
| 1.07 | Refilling of excavated soil | 19 | Cum | - | - |
| 1.08 | Sand for cushioning of the cables in the trench. | 3.44 | Cum | - | - |
| 1.09 | Cement Tiles of size 300mm length x250mm width x 37mm thick as a protective cover for underground cables. | 80 | No. | - | - |
| 1.1 | DWC PIPE, 65mm ID | 600 | Mtrs | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.11 MB
SBD082.pdf
Tender Documents • 0.43 MB
BOQ_1095546.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .