Loading…
Loading…
Ref. No.
Tender Value
Refer Docs
EMD Value
₹6.7 L
Closing Date
26 Mar 2026, 3:00 pmClosed
RAJESH KUMAR SINGH
RHQ VADODARA
construction of New Control Room Building at 400/220 kV Dehgam SS
WR2/NT/W-CIVIL/DOM/G01/26/02256
Open
Civil Works - Buildings
Works
Dehgam SS
As per bid
₹12,500
₹6.7 L
6 Mar 2026
6 Mar 2026
26 Mar 2026
6 Mar 2026
26 Mar 2026
26 Mar 2026
Name of Package : Construction of New Control Room Building at 400/220 kV Dehgam SS.
Package No : CIVIL Works Package Rfx:5002005109
Specification No. : WR2/NT/W-CIVIL/DOM/G01/26/02256
Completion Period 12 Months
: Attachments : General guidelines for filling up the Attachments : CIVIL Works Package Rfx:5002005109 :
Construction of New Control Room Building at 400/220 kV Dehgam SS.
Specification No.: WR2/NT/W-CIVIL/DOM/G01/26/02256
1 Fill up only green shaded cells in the relevent attachments.
2 Attachments 3(JV), 3(QR), Attach QR, 4, 4(A), 4(B), 5, 6, 7, 9, 10, 11, 12, 13, 14, 15, 16, 17,18, 19 and Bid Form for 1st Envelope are included here.
3 Attachment 1 Bid Security : Applicable
4 Attachment 2 Power of Attorney : No specific format is provided by POWERGRID. Bidder may use their own format.
5 Attachment 8 Manufacturer’s Authorisation Form : Not Applicable
6 Attachment 14 Integrity Pact : To be submitted as per ITB Clause No. 9.3(n) and as per remarks in the Attach 14-IP.
7 Attachment 18 Safety Pact : Not Applicable
8 Attachment 20: Declaration of Key Managerial Person jointly with Power of Attorney holder
9 Attachment 21: Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII order, if applicable
10 Attachment 22: Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order and MoP order, if applicable [to be submitted on the letter head of the issuer.]
11 Attachment 23: Undertaking regarding submission of originalHard copy part of the bid
12 Attachment 24: Affidavit of Self Certification regarding Domestic Value Addition in Iron & Steel Products to be provided on a non-judicial stamp paper of Rs. 100/-. Not Applicable
13 Attachment 25: Compliance to the process related to the e-RA Terms & Conditions and the Business Rules governing the e-RA
14 Attachment 26:Declaration by the Bidder regarding events encountered pursuant to ITB Clause 2.1
15 Attachment 27:Certification by the Bidder as per DoE Order in line with ITB Clause 2.1
16 Attachment 28:Not Applicable
Note : Enable the Active X Control & Macros. Also ensure to keep option of "Trust acess to VBA project object Model" cheched [√]. Ensure that you work on MS Excel 2007 or higher version.
Construction of New Control Room Building at 400/220 kV Dehgam SS.
WR2/NT/W-CIVIL/DOM/G01/26/02256 Sole Bidder 1
Yes JV (Joint Venture) 2 or More
Enter following details of the bidder No
Specify type of Bidder [Select from drop down menu] Sole Bidder Sole Bidder 2 0
Address of Bidder
Whether the bidder is an MSE (Micro & Small Enterprise) 0 2 2 0 2019
Enter the Name of Registration Authority 2020
E-mail ID of Bid Signatory
Mobile No. of Bid Signatory
Tel No. of Bid Signatory
Fax No. of Bid Signatory MSE 0
Name of other Partner Ram Lal
Address of other Partner G5
Name of other Partner - 2 (more, if any)
Address of other Partner - 2 (more, if any)
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Attachment-3(JV) Sole Bidder
Construction of New Control Room Building at 400/220 kV Dehgam SS.
(Joint Venture Agreement and Power of Attorney for Joint Venture*)
Bidder’s Name and Address : To:
Contract Services & Ram Lal
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Western Region Transmission System-II
0 RHQ, Plot No 54 Vadodara-390008
This Attachment is Not Applicable
Name(s) and Addresse(s) of other partner(s)
The Joint Venture Agreement (as per the proforma attached at no. 15 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) and Power of Attorney for Joint Venture (as per the proforma attached at no. 14 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) are enclosed herewith Sole Bidder
Date : -- Printed Name : 0
Place : Designation : 12
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Attachment-3(QR)
Construction of New Control Room Building at 400/220 kV Dehgam SS.
(Qualifying Requirement Data)
Bidder’s Name and Address (Lead Partner of) : To:
Contract Services
Name: 0 Power Grid Corporation of India Ltd.,
Address: 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
In support of the Qualification Requirements (QR) for bidders, stipulated in Annexure-A (BDS) of the Section - III (BDS), Volume-I & Additional Information required as per ITB clause 9.3(c) of the Bidding Documents, we furnish herewith our QR data/details along with other information, as follows herewith our stipulations have been reproduced in italics for ready reference, however, in case of any discrepancy the QR as given in BDS shall prevail).
* We have submitted bid as individual firm.
* We have submitted bid as joint venture of following firms :
(ii) #REF! 2 or more
(* Strike-off whichever is not applicable)
[For details regarding Qualification Requirements of a Joint Venture, please refer para 4.0 below.]
We are furnishing the following details/document in support of Qualifying requirement for the subject package.
A Attached copies of original documents defining :
a) The constitution or legal status;
b) The principal place of business;
c) The place of incorporation (for bidders who are corporations); or the place of registration and the nationality of the Owners (for applicants who are partnerships or individually-owned firms).
B Attached original & copies of the following documents :
a) Written power of attorney of the signatory of the Bid to commit the bidder.
b) Joint Venture Agreement.
1.0 GENERAL INFORMATION
Bidder is required to provide general information as per the following format.
[Where the Bidder proposes to use named subcontractor(s) for critical components of the works or for work contents in excess of ten (10) percent of the bid price, the following information should also be supplied for the subcontractor(s)].
S No. Particulars Name of the Bidder
1 Name of the Firm
2 Head Office/ Registered Office Address
5 Contact Person
6 Place of Incorporation/ Registration
7 Year of Incorporation/ Registration
8 Nationality of
9 Whether the bidder is an MSE (Micro & Small Enterprise). If Yes, attach Documentary Evidence with the Bid. No
10 Whether the Bidder is a Start-Ups Company (as defined by DIPP). If Yes, attach Documentary evidence with the Bid.
2.0 TECHNICAL REQUIREMENTS {Reference para 1.0 of Annexure-A (BDS)}
2.1 TECHNICAL EXPERIENCE
2.1.1 Route-1: The bidder must have designed, manufactured, tested & supplied 715 kV or higher voltage class one (1) number 1-phase Transformer of at least 500 MVA capacity or at least three (3) numbers 1-phase Transformers each having a capacity of at least 166 MVA, and the same transformer (s) should have been in satisfactory operation# for at least two (2) years on the date of bid opening as originally scheduled i.e., as on .………….(date to be inserted by CS department at the time of NIT).
2.1.2 Route-2: The bidder (s) who have established production line and testing facilities in India for 715 kV or above class transformer based on technological support of the Collaborator(s) for the equipment(s) can also be considered qualified provided, The bidder must have manufactured in India, type tested 715 kV or higher voltage class either One (1) no. 1-phase Transformer of at least 166 MVA capacity or One (1) no. 1-phase Reactor of at least 80 MVAR capacity and the same should have been supplied as on the date of bid opening as mentioned above based on technological support of Collaborator(s) provided that:- a) Collaborator(s) meets the Technical Experience criteria stipulated in Route-1. b) A legally enforceable undertaking jointly by Bidder and the Collaborator(s) (as per enclosed format in---------- of bidding document) is furnished along with the bid, to guarantee quality, timely supply, performance and warranty obligations for Five(5) years for entire quantity to be manufactured and supplied from the works in India and a confirmation letter from the Collaborator(s) along with the bid stating that Collaborator(s) shall furnish performance guarantee for an amount of 10% of the cost of such equipment(s). This performance guarantee shall be in addition to contract performance guarantee to be submitted by the bidder.
2.1.3 Route-3: In case, the bidder is an Indian Entity established as Subsidiary/JVC/Group company by its parent/principal, who have established production line and testing facilities in India for 715 kV or above class transformer based on technological support of the parent/principal for the equipment(s) can also be considered qualified provided, The bidder must have manufactured in India, type tested 715 kV or higher voltage class either One (1) no. 1-phase Transformer of at least 166 MVA capacity or One (1) no. 1-phase Reactor of at least 80 MVAR capacity and the same should have been supplied as on the date of bid opening as mentioned above based on technological support of Parent/ principal company provided that:- a) Parent / Principal Company meets the Technical Experience criteria stipulated in Route-1. b) A legally enforceable undertaking jointly by Bidder and the parent/ principal company (as per enclosed format in---------- of bidding document) is furnished along with the bid, to guarantee quality, timely supply, performance and warranty obligations for Five(5) years for entire quantity to be manufactured and supplied from the works in India and a confirmation letter from the parent/principal company along with the bid stating that parent/ principal company shall furnish performance guarantee for an amount of 10% of the cost of such equipment(s). This performance guarantee shall be in addition to contract performance guarantee to be submitted by the bidder.
In case bidder is a holding company, the technical experience referred to in para 2.1.1, 2.1.2 & 2.1.3 above shall be of that holding company only (i.e. excluding its subsidiary/group companies). In case bidder is a subsidiary of a holding company, the technical experience referred to in para 2.1.1, 2.1.2 & 2.1.3 above shall be of that subsidiary company only (i.e. excluding its holding company).
#satisfactory operation means certificate issued by the Employer certifying the operation without any adverse remarks.
2.1.4 Using the following format, each Bidder (individual firms or partners of a joint venture) is requested to list the experience as detailed above, on the basis of which the Bidder wishes to qualify. The information is to be summarised using following format for each experience of the Bidder
(The bidder shall attach documentary evidence, such as copies of utility certificates for completed contracts and copies of award letters etc. for ongoing contracts in support of his experience as listed in the following proforma for each Contract with the help of "Attach" Buttons provided in table given below).
2.2 Kindly mention below, whether 765 kV/ 400kV transformer(s) are being offered from Bidder himself OR from a qualified manufacturer [required to ascertain compliance to QR provision mentioned at para 1(C ), Annexure-A(BDS)].
(A) 765 kV Transformers being offered:
2.3 Format-A: (ROUTE-1) for 765kV Auto Transformer:
Format for the Bidder/ Collaborator/ Parent/Principal Company/Qualified Manufacturer of the Bidder who must have designed, manufactured, tested & supplied 715kV or Higher Voltage class Transformer in support of meeting the technical experience requirement of para 1(A) 1.1, Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
1 Name of Bidder/Qualified Manufacturer (as applicable) : 0 0
2 Name & Address of the Collaborator/Parent /Principal Company (if applicable) 0
3 Name of Contract Undertaken (for 715kV or Higher Voltage class Transformers)
4 Contract Reference No. & Date of Award
5 Name and Address of the Employer/Utility for whom the Contract was executed by the firm
6 Voltage Level of Transformer erected under the Contract (Indicate 715kV or above class only)
7 Indicate Number of Transformer(s) under the above contract (1 phase Transformers with rating not less than 500 MVA OR Transformers in Banks of 3 single phase units of at least 166 MVA each)
8 MVA capacity of above mentioned 1-phase units
9 Name of the substation or switchyard
10 No. of years, the above Transformer are in operation as on the date of bid opening. (Originally Scheduled)
11 Scope of work involved under the Contract
(Tick whichever is/are applicable) of Transformer of Transformer of Transformer
12 Details of documents uploaded in support of the above stated experience
2.4 Format-B: (ROUTE-2) for 765kV Auto Transformer:
Format for Bidder(s)/ Manufacturer [who have established production line and testing facilities in India for 715kV or above class Transformer based on Technology Support of Collaborator(s)], in support of meeting the requirement of para 1(A) 1.2 (Route-2), Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents
a Name of Bidder/Manufacturer
b Whether Bidder/Manufacturer has established production line and testing facilities in India for 715 kV or above class Transformer on the technological support of the Collaborator(s) ?
c Name of the Collaborator {The qualifying data/details for collaborator for the equipment is to be furnished in Format-A above)
Data/details of the Bidder/Manufacturer wishes/proposes to qualify through Route-2(Para 1.2, Annexure-A (BDS)), to be furnished below:
1 Name of Contract Undertaken
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the Bidder
4A Indicate details below in case Contract executed for Transformer
(i) Voltage Level of Transformer manufactured & type tested under the Contract based on technological support of Collaborator. (Indicate 715kV or above class only)
(ii) MVA capacity of the above mentioned single phase Transformers
(iii) Indicate Number of Transformer(s) under the contract (Indicate nos. of single phase Transformer of atleast 166MVA)
(iv) Name of the substation or switchyard
(v) Date as on which the above mentioned Transformers supplied
(vi) whether the above Transformers are in operation as on the date of bid opening(originally scheduled).(Yes/No)
(vii) Scope of work involved under the Contract
(Tick whichever is/are applicable)
of Transformer of Transformer of Transformer
4B Indicate detail below in case Contract executed for Reactor
i Voltage Level of Reactor manufactured & type tested under the Contract based on technological support of Collaborator. (Indicate 715kV or above class only)
ii MVAR capacity of the above mentioned single phase Reactors
iii Indicate Number of Reactor(s) under the contract (Indicate nos. of Reactor(s) of at least 80 MVAR each)
iv Name of the substation or switchyard
v Date as on which the above mentioned Reactors are supplied.
vi whether the above Reactors are in operation as on the date of bid opening(originally scheduled).(Yes/No)
vii No. of years, the above Reactors are in operation as on the date of bid opening (originally scheduled).
vii Scope of work involved under the Contract
(Tick whichever is/are applicable) for Reactor for Reactor for Reactor
5 Whether collaborator(s) meets the technical experience criteria stipulated at 2.1.1 above, and the details of which is mentioned at Format-A above. (Applicable for the Bidder wish/proposes to qualify through Route-2 of Annexure-A(BDS)) Yes
6 Whether legally enforceable undertaking jointly by Bidder/Manufacturer and the Collaborator(s) (as per enclosed format in Section-VI: Sample Forms and Procedures of bidding document) is furnished along with the bid. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-2 of Annexure-A(BDS))
7 Confirmation letter from the Collaborator along with the bid stating that Collaborator shall furnish performance guarantee, in addition to contract performance guarantee to be submitted by the bidder, for an amount of 10% of the cost of equipment(s) to be manufactured and supplied from the works in India. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-2 of Annexure-A(BDS)) (Choose whichever is applicable from the drop down menu)
8 Details of documents uploaded in support of the above stated experience
2.5 Format-C: (ROUTE-3) for 765kV Auto Transformer:
Format for Manufacturer of the Bidder/ Indian entity established as Subsidiary/ JVC/ Group Company by its Parent/ Principal, who have established production line and testing facilities in India for 715kV or above class Transformer, in support of meeting the requirement of para 1(A) 1.3, Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
a Name of Bidder/ Manufacturer
b Whether the bidder is an Indian Entity established as Subsidiary/JVC/Group company by its parent/principal, who have established production line and testing facilities in India for 715 kV or above class transformer based on technological support of the parent/principal?
c Name & Address of the Parent/Principal Company {The qualifying data for the Parent/Principal Company for the equipment is to be furnished in Format-A above)
Data/details of the Bidder/Manufacturer wishes/proposes to qualify through Route-3 (Para 1.3, Annexure-A (BDS)), to be furnished below:
1 Name of Contract Undertaken
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm
4A Indicate detail below in case Contract executed for Transformer
i Voltage Level of Transformer manufactured & type tested under the Contract . (Indicate 715kV or above class only)
ii Indicate Number of Transformer(s) under the contract (Indicate nos. of single phase Transformer of atleast 166MVA )
iii MVA capacity of the above mentioned single phase Transformers
iv Name of the substation or switchyard
v Date as on which the above mentioned Transformers supplied
vi whether the above Transformers are in operation as on the date of bid opening(originally scheduled).(Yes/No)
vii No. of years, the above Transformers are in operation as on the date of bid opening (originally scheduled).
viii Scope of work involved under the Contract
(Tick whichever is/are applicable) of Transformer of Transformer of Transformer
4B Indicate detail below in case Contract executed for Reactor
i Voltage Level of Reactor manufactured & type tested under the Contract (Indicate 715kV or above class only)
ii MVAR capacity of the above mentioned single phase Reactors
iii Indicate Number of Reactor(s) under the contract (Indicate nos. of Reactor(s) of at least 80 MVAR )
iv Name of the substation or switchyard
v Date as on which the above mentioned Reactors are supplied.
vi whether the above Reactors are in operation as on the date of bid opening(originally scheduled).(Yes/No)
vii No. of years, the above Reactors are in operation as on the date of bid opening(originally scheduled)..
viii Scope of work involved under the Contract
(Tick whichever is/are applicable) for Reactor for Reactor for Reactor
5 Whether Parent/Principal company(s) meets the technical experience criteria stipulated at 2.1.1 above, and the details of which is mentioned at Format-A above. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-3 of Annexure-A(BDS))
6 Whether legally enforceable undertaking jointly by Bidder/Manufacturer and the Parent/Pricipal company(s) (as per enclosed format in Section-VI: Sample Forms and Procedures of bidding document) is furnished along with the bid. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-3 of Annexure-A(BDS))
7 Confirmation letter from the Parent/Principal Company along with the bid stating that Parent/Principal Company shall furnish performance guarantee, in addition to contract performance guarantee to be submitted by the bidder, for an amount of 10% of the cost of equipment(s) to be manufactured and supplied from the works in India. (Applicable for the Bidder wish/proposes to qualify through Route-3 of Annexure-A(BDS))
8 Details of documents uploaded in support of the above stated experience
3.0 Financial Position {Reference para 2.0 of Annexure-A (BDS)}
a) Net Worth for last 3 financial years should be positive.
b) Minimum Average Annual Turnover^ (MAAT) for best three (3) years i.e. 36 months out of last five (5) financial years of the bidder should be Rs. 1451.18 million or equivalent for Auto Transformer TR09. ^ Annual gross revenue from operations/gross operating income as incorporated in the profit & loss account excluding other income”.
c) Bidder shall have liquid assets (L.A.) or/and evidence of access to or availability of credit facilities of not less than Rs. 241.86 million or equivalent for Auto Transformer TR09.
Note: (i) In case bidder is a holding company, the Financial Position criteria referred to in para 3.0 above shall be that of holding company only (i.e. excluding its subsidiary / group companies). In case bidder is a subsidiary of a holding company, the Financial Position criteria referred to in para 3.0 above shall be that of subsidiary company only (i.e. excluding its holding company). (ii) In case bidder has established manufacturing facility in India and yet to complete three (3) financial years, the Net Worth and average of the turnover as per financial statement for completed financial years shall be considered for the purpose of compliance to the specified Net Worth and MAAT requirements. (iii) In case of bidder qualifying through Route-3 but not meeting the Financial Position requirement as per note (i) read along with note (ii) above, the following shall be applicable: In case bidder is yet to complete five (5) years from the date of commercial production of such equipment(s) but no later than seven (7) years from the date of incorporation of the said company as on the originally scheduled date of bid opening as above, the financial position requirement as per para 3.0 (b) & (c) of parent/principal company providing collaboration for technological support shall be considered. However, once he meets the turnover requirement on their own or completes five (5) years from the date of commercial production of such equipment (s) in India but no later than seven (7) years from the date of incorporation as on the originally scheduled date of bid opening as above, the financial position requirements as specified at 3.0 (b) and (c) above shall be required to be met by such bidder on their own as per note (i) above and not based on their parent/principal company. Further, in case the bidder is yet to complete one (1) financial year, the Net worth requirement as per para 3.0 (a) above of parent/principal shall be considered.
(iv) Relaxation for Start-Ups^/ MSEs Start-Ups^/ MSEs, meeting the specified requirements at Para 3.0 (a) above in Financial Position shall also be considered qualified if they meet Eighty (80) % of the requirement specified at Para 3.0 (b) & 3.0 (c) above in Financial Position. ^ Start-Ups as defined by DIPP, applicable as on the originally scheduled date of bid opening.
{In support of its ‘Financial Position’, in line with the above, the Bidder or Company/Constituents must provide the relevant information in support of the same, along with documentary evidence, in the following format}
4.0 Financial Qualification Data: 2 or more
4.1 Name of the Bidder
Networth (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
Sl No Financial year
For the FY of immediately preceding the date of submission of bid.
B Turnover details:
Turnover (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
Sl No Financial year
For the FY of immediately preceding the date of submission of bid.
Average Annual Turnover for best Three Years is
C Liquid Assets
LA (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
5.0 Financial Qualification Data for Parent/Principal Company (If Applicable):
5.1 Name of the Bidder
Details of documentary evidence submitted in support of Qualification Data
Networth (in Rs. Millions)
Sl No Financial year
For the FY of immediately preceding the date of submission of bid.
B Turnover details:
Details of documentary evidence submitted in support of Qualification Data
Turnover (in Rs. Millions)
Sl No Financial year
For the FY of immediately preceding the date of submission of bid.
Average Annual Turnover for best Three Years is
C Liquid Assets
LA (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
Equivalent US$ (in Million) exchange rate* Details of documentary evidence submitted in support of Qualification Data
Networth (in Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
*(Indicate the rate(s) of exchnage against US Dollar at the end of each year, which have been used for arriving the amount at equivalent US Dollar.)
B Turnover details:
Equivalent US$ (in Million) exchange rate* Details of documentary evidence submitted in support of Qualification Data
Turnover (in Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
*(Indicate the rate(s) of exchnage against US Dollar at the end of each year, which have been used for arriving the amount at equivalent US Dollar.)
C Liquid Assets
LA Equivalent US$ (in Million)
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
Equivalent US$ (in Million) exchange rate* Details of documentary evidence submitted in support of Qualification Data
Networth (in Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
*(Indicate the rate(s) of exchnage against US Dollar at the end of each year, which have been used for arriving the amount at equivalent US Dollar.)
B Turnover details:
Equivalent US$ (in Million) exchange rate* Details of documentary evidence submitted in support of Qualification Data
Turnover (in Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Average Annual Turnover for best Three Years is
*(Indicate the rate(s) of exchnage against US Dollar at the end of each year, which have been used for arriving the amount at equivalent US Dollar.)
C Liquid Assets
LA Equivalent US$ (in Million)
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
4.0 Joint Venture (JV) Firms {Reference para 3.0 of Annexure-A (BDS)}
In case a bid is submitted by a Joint Venture (JV) of two or more firms as partners, all the partners of Joint Venture shall meet collectively requirements stipulated at clauses 3.0 (b) & 3.0 (c) above. The figure of average annual turnover and liquid assets/credit facilities for each of the partners of the JV shall be added together to determine the JV’s compliance with the minimum qualifying criteria set out in Para 3.0 (b) & (c) above.
However, for a JV to be qualified, the partner(s) of JV must also meet the following minimum criteria: i. All the partners of the JV shall meet individually the Financial Position criteria given at 3.0 (a) above. ii. The Lead Partner shall meet, not less than 40% of the minimum criteria given at clause 3.0 (b) & (c) and 100 % of the criteria given above at clause 2.1 iii. The other partner(s) shall meet not less than 25% of the criteria given at clause 3.0 (b) & (c) above and 100 % of the criteria given above at clause 2.1 or 2.2 Failure to comply with this requirement will result in rejection of the joint venture’s bid.
In case of Joint venture, the following conditions shall also apply:
(a) the bid, and in case of successful bid, the specified Form of Agreement shall be signed so as to be legally binding on all partners (as per enclosed format in Section-VI, Vol.-I of bidding document).
(b) one of the partners shall be nominated as Lead Partner, and the Lead Partner shall be authorized to incur liabilities and receive instructions for and on behalf of any and all partners of the Joint Venture, and the entire execution of the Contract shall be done with the Lead Partner and payment under the contract shall be received by the Lead Partner on behalf of the Joint Venture as per power conferred to him in the Power of Attorney. The authorization shall be evidenced by submitting a Power of Attorney signed by legally authorized signatory of all the partners as per Performa in in Section-VI, Vol.-I of bidding documents. The payment under the Contract can also be received by other partner(s) based on authorization of Lead Partner.
(c) All partners of the joint venture shall be liable jointly and severally for the execution of the Contract in accordance with the Contract terms and a statement to this effect shall be included in the authorisation mentioned under (b) above as well as in the Bid Form and in the Contract Form (in case of a successful bid);
(d) Agreement entered into by the Joint Venture partners shall be submitted with the bid.
The bidder shall furnish documentary evidence in support of the qualifying requirement stipulated as above.
4.1 In accordance with the above, in case of JV bidders, it should be ensured that necessary details including those pertaining to each JV partner are furnished and the documents are submitted alongwith the bid. Further, the JV bidders should also ensure that other requirements are complied with. The lists of documents furnished are to be indicated below :
A For Name of the Bidder
6.0 The Bidder shall also furnish following documents/details with its bid. {Reference ITB clause 9.3 (c)}
6.1 The complete annual reports together with Audited statement of accounts of the company for last five years of its own (separate) immediately preceding the date of submission of bid.
Note I. In the event the bidder is not able to furnish the information of its own (i.e separate), being a subsidiary company and its accounts are being consolidated with its group/holding/parent company, the bidder should submit the audited balance sheets, income statements, other information pertaining to it only (not of its group/Holding/Parent Company) duly certified by any one of the authority [ (i) Statutory Auditor of the bidder /(ii) Company Secretary of the bidder or (iii) A certified Public Accountant] certifying that such information/documents are based on the audited accounts as the case may be.
II. Similarly, if the bidder happens to be a Group/Holding/Parent Company, the bidder should submit the above documents/information of its own (i.e. exclusive of its subsidiaries) duly certified by any one of the authority mentioned in Note-I above certifying that these information/documents are based on the audited accounts, as the case may be.
6.2 The Bidder should accordingly also provide the following information/documents
Audited balance sheet and income statements for the last five years as per the following:
A Years preceding to the bid opening Audited Balance Sheet and Income Statements enclosed
Date : -- Printed Name :
Place : Designation :
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Attachment-3(QR)
Construction of New Control Room Building at 400/220 kV Dehgam SS.
(Qualifying Requirement Data)
Bidder’s Name and Address : To:
Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Western Region Transmission System-II
0 RHQ, Plot No 54 Vadodara-390008
For our Qualifying Requirements Data, please refer Schedule-QR of this volume.
Date : -- Printed Name :
Place : Designation :
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256
Construction of New Control Room Building at 400/220 kV Dehgam SS.
(Qualifying Requirement Data)
Bidder’s Name and Address : To:
Contract Services
Name: 0 Power Grid Corporation of India Ltd.,
Address: 0 Western Region Transmission System-II
0 RHQ, Plot No 54 Vadodara-390008
In support of the Qualification Requirements (QR) for bidders, stipulated in Annexure-A (BDS) of the Section - III (BDS), Volume-I & Additional Information required as per ITB clause 9.3(c) of the Bidding Documents, we furnish herewith our QR data/details along with other information, as follows herewith our stipulations have been reproduced in italics for ready reference, however, in case of any discrepancy the QR as given in BDS shall prevail). 1.1 Qualification of bidder will be based on meeting the minimum pass/fail criteria specified below regarding the Bidder’s Technical Experience (para 2. below) and Financial Position (para 3. below) as demonstrated by the Bidder’s responses in the document submitted during bidding. 1.2 POWERGRID reserves the right to waive minor deviations to QR, provided they do not materially affect the capability of the bidder to perform the contract. The decision of POWERGRID in this regard shall be final & binding on bidders. 1.3 The Owner may assess the capacity and capability of the bidder, to successfully execute the scope of work covered under the package within stipulated completion period. This assessment shall inter-alia include (i) document verification; (ii) bidder’s works visit; (iii) details of works executed, works in hand, anticipated in future & the balance capacity available for the present scope of work; (iv) details of plant and machinery, manpower and financial resources; (v) details of quality systems in place; (vi) past experience and performance; (vii) customer feedback; (viii) banker’s feedback, etc. 1.4 Bid can be submitted by an individual firm. Bid from Joint Venture shall not be accepted.
2.0 TECHNICAL REQUIREMENTS {Reference para 1.1 of Annexure-A (BDS)}
2.1 TECHNICAL EXPERIENCE
2.1.1 Technical Experience (2.1) Bidder should have successfully completed “Similar Works” for Central Govt/State Govt/PSU/Public Listed Company/reputed private firm during past 07 (seven) years immediately preceding originally stipulated date of bid opening of value not less than that specified below: 2.1.1) Three Similar Works^, each of not less than INR 134.82 Lakh OR 2.1.2) Two Similar Works^, each of not less than INR 168.52 Lakh OR 2.1.3) One Similar Work^ of not less than INR 269.64 Lakh. (2.1.4) Nature of Work: ‘Similar works for the package is defined as, “Any type of Building work" (2.2) Following documents shall be submitted by the bidder as evidence of above: (a) Completion certificate(s) from the client for the work inter-alia indicating final executed amount and date of completion or any other document authenticated by the client containing relevant information to conclusively establish that the bidder has completed the requisite works(s) as per the requirement specified above. (b) The copy of corresponding work orders. (c) In case the bidder has submitted credentials as sub-contractor, then the bidder shall have to submit any authenticated document to establish that the sub-contracting has been under information of the employer.
2.3 Note (a)In case the bidder is a holding company, the technical experience referred to in clause 2.1 above shall be of that holding company only (i.e. excluding its subsidiary/group companies). In case the bidder is a subsidiary of a holding company, the technical experience referred to in clause 2.1 above shall be of that subsidiary company only (i.e. excluding its holding company).
3.0 FINANCIAL REQUIREMENTS :
The bidders must meet following minimum criteria:
(3.1) The Minimum Average Annual Turnover* (MAAT) of the bidder for the best three financial years i.e. 36 months out of the last five financial years should not be less than Rs. 505.57 lakhs. * Note-Annual Gross revenue from operations/gross operating income as incorporated in the profit and loss account excluding other operative income/other income 3.4 Note: (a) In case the bidder is a holding company, the Financial Position criteria referred to in clause 3.0 above shall be that of holding company only (i.e. excluding its subsidiary / group companies). In case bidder is a subsidiary of a holding company, the Financial Position criteria referred. Relaxation for Start-ups^^/ MSEs^: (b) For Start-up^^ meeting the technical experience at 2.0 above, 20% relaxation shall be allowed in the financial requirement specified at para 3.1 (MAAT) above (c)For MSE^ bidders meeting the technical experience at 2.0 above, 100% relaxation shall be allowed in the financial requirement specified at para 3.1 (MAAT) above
^^ Start-up as defined by DPIIT, applicable as on the originally stipulated last date of bid submission. ^ MSE as defined in Public Procurement Policy for Micro and Small Enterprises (MSEs) Order, 2012 dated 23.03.2012 issued by Ministry of Micro, Small & Medium Enterprises and its subsequent Orders/ Notifications issued by concerned Ministry.
Date : -- Printed Name :
Place : Designation :
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Attachment-4
Construction of New Control Room Building at 400/220 kV Dehgam SS.
(Form of Certificate of Origin and Eligibility)
Bidder’s Name and Address : To:
Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Western Region Transmission System-II
0 RHQ, Plot No 54 Vadodara-390008
We hereby certify that equipment and materials to be supplied are produced in [Name of Countries], eligible source country. Equipments & Materials produced in [Name of countries] Company incorporated & registered in [Name of countries]
We hereby certify that our company is incorporated and registered in [Name of Countries], eligible source country. [Name of Countries] [Name of Countries] [Name of Countries], [Name of Countries],
Date : -- Printed Name :
Place : Designation :
country. country. [Name of Countries], [Name of Countries],
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Attachment-4(A)
Construction of New Control Room Building at 400/220 kV Dehgam SS.
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address : To:
Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Western Region Transmission System-II
0 RHQ, Plot No 54 Vadodara-390008
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles are included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
S.No. For Equipment Item Description Unit Quantity
Notwithstanding what is stated above, we further confirm that any additional special maintenance tools and tackles, required for the equipment under this package shall be furnished by us at no extra cost to the employer.
Date : -- Printed Name :
Place : Designation :
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Attachment-4(B)
Construction of New Control Room Building at 400/220 kV Dehgam SS.
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address : To:
Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Western Region Transmission System-II
0 RHQ, Plot No 54 Vadodara-390008
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles which are to be taken back after the completion of the work by us are not included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
Date : -- Printed Name :
Place : Designation :
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Attachment-5
Construction of New Control Room Building at 400/220 kV Dehgam SS.
(Bought-out & Sub-contracted Items)
Bidder’s Name and Address : To:
Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Western Region Transmission System-II
0 RHQ, Plot No 54 Vadodara-390008
This Attachment is Not Applicable
We hereby furnish the details of the items/ sub-assemblies, we propose to buy for the purpose of furnishing and installation of the subject Package:
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details / write-up to engage the Locals sub-contractor/sub-vendor
Name Nationality
We hereby declare that, we would not subcontract the erection portion of the contract without the prior approval of Employer.
We hereby furnish the details of the items/ sub-assemblies propose to supply from our own works (i.e. as direct transactions) in additional to the supplies the same from other vendors (i.e. as Bought-out transactions) as detailed in the table given above. In line with ITB Clause 9.3 (e), we intend to supply following items which are to be manufactured within Arunachal Pradesh. We further declare that we would source material / services for atleast 30% of the Installation Price of Services contract from within Assam
Sl. No. Item Description Quantity proposed to be supplied Details / write-up to engage the Locals sub-contractor/sub-vendor
Name of Plant Address
Date : -- Printed Name :
Place : Designation :
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Annexure I to Attachment-5
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details / write-up to engage the Locals sub-contractor/sub-vendor
Name Nationality
Date : -- Printed Name :
Place : Designation :
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Annexure I to Attachment-5
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Details of the proposed sub-contractor/sub-vendor Details / write-up to engage the Locals sub-contractor/sub-vendor
Name Nationality
Date : -- Printed Name :
Place : Designation :
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Attachment-5A
Construction of New Control Room Building at 400/220 kV Dehgam SS.
(Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises)
Bidder's Name and Address: To:
Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Western Region Transmission System-II
0 RHQ, Plot No 54 Vadodara-390008
Dear Sir, This Attachment is Not Applicable
1 We hereby furnish the details of the items, components, raw material, services which we propose to buy/avail from Micro and Small Enterprises (MSEs) for the purpose of completion of works under the subject package:
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Name of Micro and Small Enterprises (MSEs)
Name Category (Micro or Small)
2 The above is a list of items we propose to procure from MSEs. However, based on the situations during the execution of the contract, the above list may undergo changes. We hereby confirm that the details regarding actual procurement from MSEs carried out by us, as per the format provided at Section VI, Forms and Procedures, Volume-I of bidding documents, shall be submitted along with the bills for payment against supplies made/works done during execution of contract.
We hereby furnish the details of the items/ sub-assemblies propose to supply from our own works (i.e. as direct transactions) in additiona to the supplies the same from other vendors (i.e. as Bought-out transactions) as detailed in the table given above.
Sl. No. Item Description Quantity proposed to be supplied Details of the plant from where supplies are proposed.
Name of Plant Address
Date : -- Printed Name :
Place : Designation :
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Attachment-5A
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Name of Micro and Small Enterprises (MSEs)
Name Category (Micro or Small)
Date : -- Printed Name :
Place : Designation :
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Attachment-6
Construction of New Control Room Building at 400/220 kV Dehgam SS.
(Alternative, Deviations and Exceptions to the Provisions)
Bidder’s Name and Address : To:
Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Western Region Transmission System-II
0 RHQ, Plot No 54 Vadodara-390008
The bidder shall itemize any deviation from the Specifications included in his bid. Each item shall be listed (separate sheets may be used and enclosed with this Attachment) with the following information:
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
The above deviations and variations are exhaustive. We confirm that we shall withdraw the deviations proposed by us at the cost of withdrawal indicated in this attachment, failing which our bid may be rejected and Bid Security forfeited.
Date : -- Printed Name :
Place : Designation :
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Annexure I toAttachment-6
(Alternative, Deviations and Exceptions to the Provisions)
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
Date : -- Printed Name :
Place : Designation :
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Attachment-7
Construction of New Control Room Building at 400/220 kV Dehgam SS.
(Details of Alternative Bid)
Bidder’s Name and Address : To:
Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Western Region Transmission System-II
0 RHQ, Plot No 54 Vadodara-390008
This Attachment is Not Applicable
No Alternative Bid
Date : -- Printed Name :
Place : Designation :
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256
Construction of New Control Room Building at 400/220 kV Dehgam SS.
(Work Completion Schedule)
Bidder’s Name and Address : To:
Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Western Region Transmission System-II
0 RHQ, Plot No 54 Vadodara-390008
This Attachment is Not Applicable
We hereby declare that the following Work Completion Schedule shall be followed by us in furnishing and installation of the subject Package i.e., Construction of New Control Room Building at 400/220 kV Dehgam SS. for the period commencing from the effective date of Contract to us :
Sl. No. Description of Work Construction of New Control Room Building at 400/220 kV Dehgam SS.
1 Detailed Engineering and drawing submission
a) commencement
2 Procurement of equipment/ components & assembly
a) commencement
a) commencement
3 Manufacturing
a) commencement
4 Shipments & Delivery
a) commencement
5 Establishment of site office
6 Installation at Site
a) commencement
7 Testing & Pre-commissioning
a) commencement
8 Trial Operation
a) commencement
Date : -- Printed Name :
Place : Designation :
Note : Bidders to enclose a detailed network covering all the activities to be undertaken for completion of the project indicating key dates for various milestones for each phase constituent-wise.
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Attachment-10
Construction of New Control Room Building at 400/220 kV Dehgam SS.
(Guarantee Declaration)
Bidder’s Name and Address : To:
Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Western Region Transmission System-II
0 RHQ, Plot No 54 Vadodara-390008
Dear Sir, We conform that the equipments offerred shall have minimum performance specified in Technical Specification. We further guarantee the performance/efficiency of the equipments in response to the Technical Specifications.
Date -- Printed Name :
Place : Designation :
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Attachment-11
Construction of New Control Room Building at 400/220 kV Dehgam SS.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Bidder’s Name and Address : To:
Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Western Region Transmission System-II
0 RHQ, Plot No 54 Vadodara-390008
We declare that we are aware of and have gone through the “Code of Business Conduct and Ethics for Senior Management Personnel”1 and “Code of Business Conduct and Ethics for Board Members”1 of POWERGRID (hereinafter referred to as the “Code of Conduct”). We further understand that as per the “Code of Conduct”, Senior Management Personnel including Board Members, who have retired/resigned from POWERGRID, shall not accept any appointment or post, as detailed in the referred “Code of Conduct”, within 1 year from the date of cessation of service/directorship unless approved by the Competent Authority. Accordingly, we hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation*
*In case the date of joining in the bidder’s organization of such ex-employee is within 1 year from the date of retirement/resignation from POWERGRID, No Objection Certificate/ approval from the Competent Authority must be furnished along with the bid or subsequent through clarification pursuant to ITB Clause 21.
In case of non-submission of No Objection Certificate/approval of the Competent Authority, as required, We understand that POWERGRID shall deal with such cases as per its Policy and procedures in vogue, which may also result in rejection of our bid. We also confirm that POWERGRID shall be the sole judge in this regard. We further declare that any misrepresentation or submission of false/forged documents/information in this regard shall be dealt with as per the provisions of the Integrity Pact and/or the Bidding Documents and/or POWERGRID’s policy and procedures.
Date : -- Printed Name :
Place : Designation :
Note: 1. “Code of Business Conduct and Ethics for Senior Management Personnel” and “Code of Business Conduct and Ethics for Board Members” are available on POWERGRID’s website https://www.powergridindia.com. 2. The information in similar format should be furnished for each partner of joint venture in case of joint venture bid. 3. In case bidder has furnished no details on ex-employees of POWERGRID or has left blank or has indicated ‘-‘ against the same, it shall be deemed that they have not employed any such person in their organization.
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Attachment-11
Construction of New Control Room Building at 400/220 kV Dehgam SS.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract Services
Name : Ram Lal Power Grid Corporation of India Ltd.,
Address : G5 Western Region Transmission System-II
Gurgaon RHQ, Plot No 54 Vadodara-390008
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : -- Printed Name :
Place : Designation :
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Attachment-11
Construction of New Control Room Building at 400/220 kV Dehgam SS.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : Western Region Transmission System-II
RHQ, Plot No 54 Vadodara-390008
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : -- Printed Name :
Place : Designation :
Specification No.: WR2/NT/W-CIVIL/DOM/G01/26/02256 ATTACHMENT-12
Construction of New Control Room Building at 400/220 kV Dehgam SS.
(Price Adjustment Data)
Bidder’s Name and Address (Sole Bidder) : To:
0 Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : Western Region Transmission System-II
RHQ, Plot No 54 Vadodara-390008
We have quoted our bid price on firm/fixed price basis
Sl. No. Name of Materials/Labour Value of co-efficient Name of the published index Value of index as 30 days prior to date set for opening of bids
In accordance with Clause 2, Appendix-2, Form of Contract Agreement, Section-VI; Forms. Volume-I
A) For Equipment Ex-Works Price Component
I. Circuit Breaker
a) Raw Material
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
II Current Transformer
a) Raw Material
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
a) Raw Material
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.65 to 0.73 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
II Insulating Oil
S.N. Name of Materials/Labour Value of Coefficient Name of the published index Value of index as 30 days prior to date set for opening of bids
III Capacitive VoltageTransformer
a) Raw Material
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
a) Raw Material
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
IV Surge Arrester
a) Raw Material
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
V PVC/XLPE Insulated Power and Control Cable
a) a=PVC Compound 0.15
b) Published Price of Metal IEEMA
i) Aluminium per MT IEEMA
ii) Copper per MT IEEMA
c) Weight in MT of Metal per kM (Size wise)
VI Substation Structures
i) Lattice Steel Structures & Pipe Structures (including bolts & nuts, washers & foundation bolts)
a) Raw Materials
i) a=Structural steel 0.58 JPC Market Price (Retail) for average Price of Steel Angles of size 50 x 50 x 6 mm of all cities in Rs./MT as published by Joint Plant Committee(JPC).
ii) b=Electrolytic Zinc 0.16 IEEMA
b) Labour 0.11 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
VIII. Series Reactor [ 420 kV, 12 ohm, 2500A, 1-ph air core dry type Series Reactor]
a) Raw Material Copper(a)
i) Aluminium(a) Aluminium(a)
b) Labour I= 0.85 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The value of coefficient for raw materials: a=0.65 to 0.73 and value of coefficient for labour shall be between 0.12 and 0.20, so that sum of all the coefficients including labour shall be a+l=0.85
B. For Installation Price Component
I Installation price component (including Civil works but excluding ‘supply & placement of reinforcement steel’ and ‘concreting’)
i) Labour I= 0.80 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
II Supply & Placement of Reinforcement Steel
i) HSD 0.10 Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) Labour I= 0.05 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
iii) Manufacture of Basic Metals 0.65 Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
III For Concereting
i) HSD 0.20 Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) Labour I= 0.10 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
iii) Manufacture of cement, lime and plaster 0.30 Wholesale Price Index Number for `Manufacture of cement, lime and plaster’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in)
iv) Cutting, shaping and finishing of stone 0.20 Wholesale Price Index Number for `Cutting, shaping and finishing of stone’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
The Bidders are required to estimate and indicate the values of different coefficients for each of the items in the price variation formulae within the specified range such that their summation is as specified in the Bidding Documents. Where no value or ‘-’ or ‘shall be furnished later’ is specified against the coefficient, the same will be deemed to be zero and the fixed component would be suitably adjusted. If the values of all coefficients in price variation formulae indicated by the Bidder are within the specified range but their sum exceeds the summation specified in the Bidding Documents, the values of the coefficients shall be pro-rata adjusted such that the summation remains as per the provisions of the Bidding Documents. If the values of all coefficients indicated by the Bidder are within the specified range but their summation is less than the value specified in the Bidding Documents, the values of the coefficients as indicated by the Bidder shall be considered as such and the fixed component in the price variation formulae would be suitably adjusted. Further, if any of values of the coefficients indicated by the Bidder is out of the range specified in the Bidding Documents, the lower of the values, as indicated by the Bidder vis-à-vis lower value of the range for that coefficient specified in the Bidding Documents, shall be considered and the fixed component would be suitably adjusted.
Date : Printed Name : 0
Place : 0 Designation :
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 ATTACHMENT-12
Construction of New Control Room Building at 400/220 kV Dehgam SS.
(Price Adjustment Data)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No.-2
0 Gurgaon (Haryana) - 122001
We hereby furnish the relevant details pertaining to the price adjustment provisions for equipment as specified in your specifications and documents for the subject package. The necessary documentary evidence is enclosed.
Sl. No. Name of Materials/Labour Value of co-efficient Name of the published index Value of index as 30 days prior to date set for opening of bids
In accordance with Clause 2, Appendix-2, Form of Contract Agreement, Section-VI; Forms. Volume-I
A. Price Adjustment for Erection Price Component
1 Erection price component {including Civil Works but excluding ‘Supply & Placement of reinforcement steel’ and ‘Concreting’}
i) High Speed Diesel, coefficient a = Wholesale Price Index Number for `HSD’ (Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in)
ii) Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in)
Coefficient ‘a’ shall be between 0.20 to 0.24 and Coefficient ‘l’ shall be between 0.56 to 0.60 and sum of Coefficients ‘a’ and ‘l’ shall be 0.80
2 Supply and placement of reinforcement steel
i) HSD, a= Wholesale Price Index Number for `HSD’ (Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in)
ii) Labour, l= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
iii) Manufacture of Basic Metals, b= Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
Coefficient ‘a’ shall be between 0.09 to 0.11, Coefficient ‘b’ shall be between 0.63 to 0.67 and coefficient ‘l’ shall be between 0.04 to 0.06 and sum of Coefficients ‘a’, ‘b’ and ‘l’ shall be 0.80
3 For Concereting
i) HSD, a= Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in)
ii) Labour, l= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
iii) Manufacture of cement, lime and plaster, b= Wholesale Price Index Number for `Manufacture of cement, lime and plaster’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in)
iv) Cutting, shaping and finishing of stone, c= Wholesale Price Index Number for `Cutting, shaping and finishing of stone’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
Coefficient ‘a’ shall be between 0.18 to 0.22, Coefficient ‘b’ shall be between 0.25 to 0.35, Coefficient ‘c’ shall be between 0.18 to 0.22 and Coefficient ‘l’ shall be between 0.09 to 0.11 and sum of Coefficients ‘a’, ‘b’, ‘c’ and ‘l’ shall be 0.80
The Bidders are required to estimate and indicate the values of different coefficients for each of the items in the price variation formulae within the specified range such that their summation is as specified in the Bidding Documents. Where no value or ‘-’ or ‘shall be furnished later’ is specified against the coefficient, the same will be deemed to be zero and the fixed component would be suitably adjusted. If the values of all coefficients in price variation formulae indicated by the Bidder are within the specified range but their sum exceeds the summation specified in the Bidding Documents, the values of the coefficients shall be pro-rata adjusted such that the summation remains as per the provisions of the Bidding Documents. If the values of all coefficients indicated by the Bidder are within the specified range but their summation is less than the value specified in the Bidding Documents, the values of the coefficients as indicated by the Bidder shall be considered as such and the fixed component in the price variation formulae would be suitably adjusted. Further, if any of values of the coefficients indicated by the Bidder is out of the range specified in the Bidding Documents, the lower of the values, as indicated by the Bidder vis-à-vis lower value of the range for that coefficient specified in the Bidding Documents, shall be considered and the fixed component would be suitably adjusted.
Date : -- Printed Name :
Place : Designation :
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Attachment-13
Construction of New Control Room Building at 400/220 kV Dehgam SS.
(Declaration regarding Social Accountability)
Bidder’s Name and Address : To:
Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Western Region Transmission System-II
0 RHQ, Plot No 54 Vadodara-390008
We conform that we stand committed to comply to all requirements of Social Accountability Standards i.e., SA8000 (latest Standard available at www.sa-intl.org) and maintain the necessary records.
Date : -- Printed Name :
Place : Designation :
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Attachment-14
Construction of New Control Room Building at 400/220 kV Dehgam SS.
Bidder’s Name and Address : To:
Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Western Region Transmission System-II
0 RHQ, Plot No 54 Vadodara-390008
Integrity Pact is annexed herewith this Volume.
Date : -- Printed Name :
Place : Designation :
Instruction for printing & submitting Integrity Pact
1. The requisite format of Integrity Pact is getting generated automatically and displayed here below.
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other seven pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Integrity Pact shall be signed by the authorised representative of the bidder and duly stamped.
4. Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
Power Grid Corporation of India Limited
having its Registered Office at B-9, Qutab Institutional Area, Katwaria Sarai, New Delhi – 110016 hereinafter referred to as
Individual Firm
hereinafter referred to as
"The Bidder/Contractor"
POWERGRID intends to award, under laid-down organisational procedures, contract(s) for Tower Package (Package-P238-TW05 ) for 765kV S/C (100 km.) & 765 kV D/C (62 km.) Gwalior-Jaipur Transmission Line (Part-I) associated with Phase-I Generation Projects in Orissa (Part -C)
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 1 of 8
In order to achieve these goals, POWERGRID and the above named Bidder/Contractor enter into this agreement called 'Integrity Pact' which will form a part of the bid.
It is hereby agreed by and between the parties as unde r:
Section I - Commitments of POWERGRID
(1) POWERGRID commits itself to take all measures necessary to prevent corruption and to observe the following principles :
a) No employee of POWERGRID, personally or through family members, will in connection with the tender, or the execution of the contract, demand, take a promise for or accept, for him/herself or third person, any material or other benefit which he/she is not legally entitled to.
b) POWERGRID will, during the tender process treat all Bidder(s) with equity and fairness. POWERGRID will in particular, before and during the tender process, provide to all Bidder(s) the same information and will not provide to any Bidder(s) confidential/ additional information through which the Bidder(s) could obtain an advantage in relation to the tender process or the contract execution.
c) POWERGRID will exclude from evaluation of Bids its such employee(s) who has any personnel interest in the Companies/Agencies participating in the Bidding/Tendering process.
(2) If Chairman and Managing Director obtains information on the conduct of any employee of POWERGRID which is a criminal offence under the relevant Anti-Corruption Laws of India, or if there be a substantive suspicion in this regard, he will inform its Chief Vigilance Officer and in addition can initiate disciplinary actions under its Rules.
Section II - Commitments of the Bidder/Contractor
(1) The Bidder/Contractor commits himself to take all measures necessary to prevent corruption. He commits himself to observe the following principles during his participation in the tender process and during the contract execution :
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 2 of 8
a) The Bidder/Contractor will not, directly or through any other person or firm, offer, promise or give to POWERGRID, or to any of POWERGRID's employees involved in the tender process or the execution of the contract or to any third person any material or other benefit which he/she is not legally entitled to, in order to obtain in exchange an advantage during the tender process or the execution of the contract.
b) The Bidder/Contractor will not enter into any illegal agreement or understanding, whether formal or informal with other Bidders/Contractors. This applies in particular to prices, specifications, certifications, subsidiary contracts, submission or non-submission of bids or actions to restrict competitiveness or to introduce cartelization in the bidding process.
c) The Bidder/Contractor will not commit any criminal offence under the relevant Anti-corruption Laws of India; further, the Bidder/Contractor will not use for illegitimate purposes or for purposes of restrictive competition or personal gain, or pass on to others, any information provided by POWERGRID as part of the business relationship, regarding plans, technical proposals and business details, including information contained or transmitted electronically.
d) The Bidder/Contractor of foreign origin shall disclose the name and address of the Agents/representatives in India, if any, involved directly or indirectly in the Bidding. Similarly, the Bidder/Contractor of Indian Nationality shall furnish the name and address of the foreign principals, if any, involved directly or indirectly in the Bidding.
e) The Bidder/Contractor will, when presenting his bid, disclose any and all payments he has made, or committed to or intends to make to agents, brokers or any other intermediaries in connection with the award of the contract and/or with the execution of the contract.
f) The Bidder/Contractor will not misrepresent facts or furnish false/forged documents/informations in order to influence the bidding process or the execution of the contract to the detriment of POWERGRID.
(2) The Bidder/Contractor will not instigate third persons to commit offences outlined above or be an accessory to such offences.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 3 of 8
Section III- Disqualification from tender process and exclusion from future contracts
(1) If the Bidder, before contract award, has committed a serious transgression through a violation of Section II or in any other form such as to put his reliability or credibility as Bidder into question, POWERGRID may disqualify the Bidder from the tender process or terminate the contract, if already signed, for such reason.
(2) If the Bidder/Contractor has committed a serious transgression through a violation of Section II such as to put his reliability or credibility into question, POWERGRID may after following due procedures also exclude the Bidder/Contractor from future contract award processes. The imposition and duration of the exclusion will be determined by the severity of the transgression. The severity will be determined by the circumstances of the case, in particular the number of transgressions, the position of the transgressors within the company hierarchy of the Bidder/Contractor and the amount of the damage. The exclusion will be imposed for a minimum of 12 months and maximum of 3 years.
(3) If the Bidder/Contractor can prove that he has restored/recouped the damage caused by him and has installed a suitable corruption prevention system, POWERGRID may revoke the exclusion prematurely.
Section IV - Liability for violation of Integrity Pact
(1) If POWERGRID has disqualified the Bidder from the tender process prior to the award under Section III, POWERGRID may forfeit the Bid Guarantee under the Bid.
(2) If POWERGRID has terminated the contract under Section III, POWERGRID may forfeit the Contract Performance Guarantee of this contract besides resorting to other remedies under the contract.
Section V- Previous Transgression
(1) The Bidder shall declare in his Bid that no previous transgressions occurred in the last 3 years with any other Public Sector Undertaking or Government Department that could justify his exclusion from the tender process.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 4 of 8
(2) If the Bidder makes incorrect statement on this subject, he can be disqualified from the tender process or the contract, if already awarded, can be terminated for such reason.
Section VI - Equal treatment to all Bidders / Contractors
(1) POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
(2) POWERGRID will disqualify from the tender process any bidder who does not sign this Pact or violate its provisions.
Section VII - Punitive Action against violating Bidders / Contractors
If POWERGRID obtains knowledge of conduct of a Bidder or a Contractor or his subcontractor or of an employee or a representative or an associate of a Bidder or Contractor or his Subcontractor which constitutes corruption, or if POWERGRID has substantive suspicion in this regard, POWERGRID will inform the Chief Vigilance Officer (CVO).
(*)Section VIII - Independent External Monitor/Monitors
(1) POWERGRID has appointed a panel of Independent External Monitors (IEMs) for this Pact with the approval of Central Vigilance Commission (CVC), Government of India, out of which one of the IEMs has been indicated in the NIT/IFB.
(2) The IEM is to review independently and objectively, whether and to what extent the parties comply with the obligations under this agreement. He has right of access to all project documentation. The IEM may examine any complaint received by him and submit a report to Chairman-cum-Managing Director, POWERGRID, at the earliest. He may also submit a report directly to the CVO and the CVC, in case of suspicion of serious irregularities attracting the provisions of the PC Act. However, for ensuring the desired transparency and objectivity in dealing with the complaints arising out of any tendering process, the matter shall be referred to the full panel of IEMs, who would examine the records, conduct the investigations and submit report to Chairman-cum-Managing Director, POWERGRID, giving joint findings.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 5 of 8
(3) The IEM is not subject to instructions by the representatives of the parties and performs his functions neutrally and independently. He reports to the Chairman-cum-Managing Director, POWERGRID.
(4) The Bidder(s)/Contractor(s) accepts that the IEM has the right to access without restriction to all documentation of POWERGRID related to this contract including that provided by the Contractor/Bidder. The Bidder/Contractor will also grant the IEM, upon his request and demonstration of a valid interest, unrestricted and unconditional access to his documentation. The same is applicable to Subcontractors. The IEM is under contractual obligation to treat the information and documents of the Bidder(s)/Contractor(s)/Subcontractor(s) with confidentiality.
(5) POWERGRID will provide to the IEM information as sought by him which could have an impact on the contractual relations between POWERGRID and the Bidder/Contractor related to this contract.
(6) As soon as the IEM notices, or believes to notice, a violation of this agreement, he will so inform the Chairman-cum-Managing Director, POWERGRID and request the Chairman-cum-Managing Director, POWERGRID to discontinue or take corrective action, or to take other relevant action. The IEM can in this regard submit non-binding recommendations. Beyond this, the IEM has no right to demand from the parties that they act in a specific manner, refrain from action or tolerate action. However, the IEM shall give an opportunity to POWERGRID and the Bidder/Contractor, as deemed fit, to present its case before making its recommendations to POWERGRID.
(7) The IEM will submit a written report to the Chairman-cum-Managing Director, POWERGRID within 8 to 10 weeks from the date of reference or intimation to him by POWERGRID and, should the occasion arise, submit proposals for correcting problematic situations.
(8) If the IEM has reported to the Chairman-cum-Managing Director, POWERGRID, a substantiated suspicion of an offence under relevant Anti-Corruption Laws of India, and the Chairman-cum-Managing Director, POWERGRID has not, within the reasonable time taken visible action to proceed against such offence or reported it to the CVO, the Monitor may also transmit this information directly to the CVC, Government of India.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 6 of 8
(9) The word ‘IEM’ would include both singular and plural.
(*) This Section shall be applicable for only those packages wherein the IEMs have been identified in Section – I : Invitation for Bids and/or Clause ITB 9.3 in Section – III: Bid Data Sheets of Conditions of Contract, Volume-I of the Bidding Documents.
Section IX - Pact Duration
This Pact begins when both parties have legally signed it. It expires for the Contractor after the closure of the contract and for all other Bidder's six month after the contract has been awarded.
Section X - Other Provisions
(1) This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration/Conciliation clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under Integrity Pact.
(2) Changes and supplements as well as termination notices need to be made in writing.
(3) If the Contractor is a partnership firm or a consortium or Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venture partners.
(4) Nothing in this agreement shall affect the rights of the parties available under the General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
(5) Views expressed or suggestions/submissions made by the parties and the recommendations of the CVO/IEM# in respect of the violation of this agreement, shall not be relied on or introduced as evidence in the arbitral/conciliation or judicial proceedings (arising out of the arbitral/conciliation proceedings) by the parties in connection with the disputes/differences arising out of the subject contract.
# CVO shall be applicable for packages wherein IEM are not identified in Section IFB/BDS of Condition of Contract, Volume-I. IEM shall be applicable for packages wherein IEM are identified in Section IFB/BDS of Condition of Contract, Volume-I.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 7 of 8
(6) Should one or several provisions of this agreement turn out to be invalid, the remainder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
Signature Signature
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
(Office Seal) (Office Seal)
Designation : #REF!
Witness 1 : Witness 1 :
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Integrity Pact Page 8 of 8
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Attachment-15
Construction of New Control Room Building at 400/220 kV Dehgam SS.
Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
Bidder’s Name and Address : To:
Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Western Region Transmission System-II
0 RHQ, Plot No 54 Vadodara-390008
I We have read the provisions in the Bidding Documents regarding furnishing the option for advance payment. Accordingly, as per ITB Clause 9.3 as provided in Section BDS, Section III, Vol.-I of the Bidding Documents, we hereby confirm to opt the following:
Interest Bearing Initial Advance
Supply Portion:
Services Portion:
I We are furnishing the following details of Statutory Registration Numbers and details of Bank for electronic payment.
1. Name of the Supplier/ Contractor in whose favour payment is to be made 0
2. Address with PIN Code and State
Registered Office:
Correspondence Address:
3. (a) Status – Company/others
[Declaration of Micro/ Small/ Medium Enterprise under Micro/ Small & Medium Enterprises Development Act 2006, if applicable]
3. (b) Are you a MSE owned by SC/ST* entrepreneurs in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012 including subsequent amendment/notification/order (Indicate Yes/No) Note: Documentary evidence is to be attached. Please refer remarks at the end of the attachment. No
3. (c ) If 3(b) is ‘Yes’ please mention whether you are (Proprietary MSE/ Partnership MSE/ Private Limited Company) owned by SC/ST entrepreneurs
3. (d ) Are you a MSE owned by women in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012, Public Procurement Policy for Micro and Small Enterprises (MSEs) Amendment order 2018 including subsequent amendment/notification/order (Indicate Yes/No) Note: Documentary evidence is to be attached.
4. Permanent Account (PAN) No.
5. GSTIN Numbers
I. GSTIN in the Sates/UT from where the supply of goods take place
Name of the States/UT GSTIN number
II. GSTIN in the States/UT where the supply for services take place (states where sites under the subject package is situated)
Name of the States/UT GSTIN number
6 PF Registration No. of the Company
7 PF Regional Office covered (with Address)
8 Name of Contact Person
9 Contact Details
10 Bank Details for Electronic Payment
Name of the Bank:
Address of Branch:
Type of Account:
Type of Account: Current Account
11 9 digit MICR code printed at bottom in middle, next to cheque no.
12 IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
We hereby declare that the above information are true and correct and we agree that the payment on account of this Contract, in the event of award, be made in the above account maintained in the above mentioned Bank.
*The definition of MSEs owned by SC/ST is as given under:
a. In case of proprietary MSE, proprietor(s) shall be SC /ST.
b. In case of partnership MSE, the SC/ST partners shall be holding at least 51% shares in the unit.
c. In case of Private Limited companies, at least 51% share shall be held by SC/ST promoters.
Documentary evidence: Please provide scanned copy(ies) of the SC/ST certificate(s) issued by District Authority as applicable for SC/ST MSE category as per (a), (b) or (c) above.
Date : -- Printed Name :
Place : Designation :
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Attachment-16
Construction of New Control Room Building at 400/220 kV Dehgam SS.
(Additional Information)
Bidder’s Name and Address : To:
Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Western Region Transmission System-II
0 RHQ, Plot No 54 Vadodara-390008
In support of the additional information required as per ITB Sub-Clause 9.3 (q) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
1.0 The Bidder shall furnish
A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3(q)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the Bidder (Sole Bidder) 0
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
(iii) As per para BDS/ITB clause 9.3q, Bidder shall furnish the details of their Provident Fund Code Number
Sl. No. Name of Bidders/JV Partners Provident Fund Code Number Details
2.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(q)(ii)]
2.1 Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.0 Details regarding previous transgressions of Integrity Pact
The bidder should provide detailed information on any transgression of Integrity Pact that occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country.
3.1 Details regarding previous transgressions of Integrity Pact that occurred in the last 10 years
Year Name of client Details of Transgression of Integrity Pact by the bidder
4.0 OTHER INFORMATION
4.1 Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
4.2 Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
Date : -- Printed Name :
Place : Designation :
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Attachment-17
Construction of New Control Room Building at 400/220 kV Dehgam SS.
(Declaration for tax exemptions, reductions, allowances or benefits)
Bidder’s Name and Address : To:
Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Western Region Transmission System-II
0 RHQ, Plot No 54 Vadodara-390008
1 We confirm that we are solely responsible for obtaining following tax exemptions, reductions, allowances or benefits in respect of supplies under the subject package, in case of award. We further confirm that we have considered the same in our bid thereby passing on the benefit to POWERGRID while quoting our prices. In case of our failure to receive such benefits, partly or fully, for any reason whatsoever, the Employer will not compensate us.
2 We are furnishing the following information required by the Employer for issue of requisite certificate if and as permitted in terms of the applicable Govt. of India policies/procedures (in case of award):
Applicable Act, Notification No. and Clause Ref. No. Sl. No. Description of item on which applicable Country of origin Remarks, if any
(The requirements listed above are as per current Notification of Govt. of India indicated above. These may be modified, if necessary, in terms of the Notifications.)
Date : -- Printed Name :
Place : Designation :
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Attachment-17
Construction of New Control Room Building at 400/220 kV Dehgam SS.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract Services
Name : …… ……. …….. …… ……. …….. Power Grid Corporation of India Ltd.,
Address : …… ……. …….. …… ……. …….. Western Region Transmission System-II
…… ……. …….. …… ……. …….. RHQ, Plot No 54 Vadodara-390008
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : -- Printed Name :
Place : Designation :
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Attachment-17
Construction of New Control Room Building at 400/220 kV Dehgam SS.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : Western Region Transmission System-II
RHQ, Plot No 54 Vadodara-390008
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : -- Printed Name :
Place : Designation :
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Attachment-19
Construction of New Control Room Building at 400/220 kV Dehgam SS.
Bidder’s Name and Address : To:
Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Western Region Transmission System-II
0 RHQ, Plot No 54 Vadodara-390008
Further, we hereby confirm that except as mentioned in the Attachment – 6 (Alternative, Deviations and Exceptions to the Provisions) hereof forming part of our First Envelope :
Date : -- Printed Name :
Place : Designation :
Specification No. :WR2/NT/W-CIVIL/DOM/G01/26/02256 Bid Form 1st Envelope 1 one 1 st 1 January
2 two 2 nd 2 February
BID FORM (First Envelope) 3 three 3 rd 3 March
4 four 4 th 4 April
Bid Proposal Ref. No. 5 five 5 th 5 May
Date : -- 6 six 6 th #VALUE! 6 June
7 seven 7 th #VALUE! 7 July
To: 8 eight 8 th #VALUE! 8 August
Contract Services 9 nine 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 ten 10 th 10 October
Western Region Transmission System-II 11 eleven 11 th 11 November
RHQ, Plot No 54 Vadodara-390008 12 twelve 12 th 12 December
13 thirteen 13 th
14 fourteen 14 th
Name of Contract : Construction of New Control Room Building at 400/220 kV Dehgam SS. 15 fifteen 15 th
Dear Ladies and/or Gentlemen, Enter details here. 16 sixteen 16 th
1.0 Having examined the Bidding Documents, including Amendment Nos. dated …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). 17 seventeen 17 th
1.1 We meet the eligibility requirements and have no conflict of interest in accordance with ITB Clause 2.
2.0 Attachments to the Bid Form (First Envelope) Bank Draft 18 eighteen 18 th
In line with the requirement of the Bidding Documents, we enclose herewith the following Attachments: Pay Order 19 nineteen 19 th
(a) Attachment 1(CIVIL Works Package Rfx:5002005109) : BID SECURITY FORM in Volume I Annexure E (BDS) Banks certified Cheque Zero 20 twenty 20 th
or documentary evidence in support of exemption of Bid Security, in separate envelope in accordance with clause 21 of ITB, Section-II." Please note that if bid validity is less than 250 days, your bid may be rejected
(b) Attachment 2(CIVIL Works Package Rfx:5002005109) : A power of attorney duly authorized by a Notary Public indicating that the person(s) signing the bid have the authority to sign the bid and thus that the bid is binding upon us during the full period of its validity in accordance with the ITB Clause 14. Bank Guarantee (0) 21 st
*Further the requisite deed of Joint Undertaking as per stipulated qualification requirement in Annexure-A (BDS) has also been furnished as per your format.
* Delete if not applicable
(c) Attachment 3(CIVIL Works Package Rfx:5002005109) : The documentary evidence that we are eligible to bid in accordance with ITB Clause 2. Further, in terms of ITB Clause 9.3(c) & (e), the qualification data has been furnished as per your format enclosed with the bidding documents [Attachment – 3(QR)]. 22 th
Further, the required Joint Venture Agreement signed by us and our Partners has also been furnished as per your format Attachment-3(JV). #REF! Applicable 23 th
Further the required deed of Joint Undertaking signed by us and Tower Manufacturer has also been furnished as per your format. 0 #REF! Not Applicable 24 th
(d) Attachment 4(CIVIL Works Package Rfx:5002005109) : The documentary evidence establishing in accordance with ITB Clause 3, Vol.-I of the Bidding Documents that the facilities offered by us are eligible facilities and conform to the Bidding Documents has been furnished as Attachment 4. A list of Special Tools & Tackles to be used by us for erection, testing & Commissioning and to be handed over to Employer, the cost of which is included is our Bid Price, is also enclosed as per your format as Attachment 4A. A list of Special Tools & Tackles to be brought by the contractor for erection, testing & Commissioning and to be taken back after completion of work, whose cost in not included in our bid price, is enclosed as per your format as Attachment 4B. 25 th
(e) Attachment 5(CIVIL Works Package Rfx:5002005109) : NA 26 th
(f) Attachment 5A(CIVIL Works Package Rfx:5002005109) : NA 26 th
(g) Attachment 6(CIVIL Works Package Rfx:5002005109) : The variation and deviations from the requirements of the Conditions of Contract, Technical Specification and Drawings (excluding critical provisions as mentioned at clause 6.0 below) in your format enclosed with the Bidding Documents, including, inter alia, the cost of withdrawal of the variations and deviations indicated therein. 27 th
(h) Attachment 7(CIVIL Works Package Rfx:5002005109) : NA 28 th
(i) Attachment 8(CIVIL Works Package Rfx:5002005109) : NA 29 th
(j) Attachment 9(CIVIL Works Package Rfx:5002005109) : NA 30 th
(k) Attachment 10(CIVIL Works Package Rfx:5002005109) : Guarantee Declaration. 31 st
(l) Attachment 11(CIVIL Works Package Rfx:5002005109) : Information regarding ex-employees of Employer in our firm.
(m) Attachment 12(CIVIL Works Package Rfx:5002005109) : Filled up information regarding Price Adjustment Data as per the format enclosed in the bidding documents.
(n) Attachment 13(CIVIL Works Package Rfx:5002005109) : Declaration regarding Social Accountability.
(o) Attachment 14(CIVIL Works Package Rfx:5002005109) : Integrity Pact, in a separate envelope, duly signed on each page by the person signing the bid.
(p) Attachment 15(CIVIL Works Package Rfx:5002005109) : Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
(q) Attachment 16(CIVIL Works Package Rfx:5002005109) : Additional Information.
(r) Attachment 17(CIVIL Works Package Rfx:5002005109) : Declaration for tax exemptions, reductions, allowances or benefits
(s) Attachment 18(CIVIL Works Package Rfx:5002005109) : NA
(t) Attachment 19(CIVIL Works Package Rfx:5002005109) : Declaration.
(u) Attachment 20(CIVIL Works Package Rfx:5002005109) : Declaration of Key Managerial Person jointly with Power of Attorney holder
(v) Attachment 21(CIVIL Works Package Rfx:5002005109) : Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII order and MoP Order, if applicable
(w) Attachment 22(CIVIL Works Package Rfx:5002005109) : NA
(x) Attachment 23(CIVIL Works Package Rfx:5002005109) : NA
(y) Attachment 24(CIVIL Works Package Rfx:5002005109) : NA
(z) Attachment 25(CIVIL Works Package Rfx:5002005109) : Compliance to the process related to the e-RA Terms & Conditions and the Business Rules governing the e-RA
(aa) Attachment 26(CIVIL Works Package Rfx:5002005109) : Declaration by the Bidder regarding events encountered pursuant to ITB Clause 2.1
(ab) Attachment 27(CIVIL Works Package Rfx:5002005109) : Certification by the Bidder per DoE Order in line with ITB Clause 2.1
(ac) Attachment 28(CIVIL Works Package Rfx:5002005109) : NA
3.0 We are aware that, in line with Clause No. 27.1 (ITB), our Second Envelope (Price Part) is liable to be rejected in case the same contains any deviation/omission from the contractual and commercial conditions and technical Specifications other than those identified in this First Envelope.
4.0 We confirm that except as otherwise specifically provided our Bid Prices in Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
4.1 100% of applicable Taxes and Duties i.e. GST, which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
4.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
5.0 Construction of the Contract
5.1 We declare that we have studied Clause GCC 2.1 relating to mode of contracting for Domestic Bidders and we are making this proposal with a stipulation that you shall award us two separate Contracts viz ‘First Contract’ for ex-works supply of all equipment and materials including mandatory spares and ‘Second Contract’ for providing all the services i.e. inland transportation for delivery at site, In-transit insurance, unloading, handling at site, installation, testing and commissioning including Trial operation in respect of all the equipment supplied under the ‘First Contract’ and other services specified in the Contract Documents. We declare that the award of two contracts, will not, in any way, dilute our responsibility for successful operation of plant/equipment and fulfillment of all obligations as per Bidding Documents and that both the Contracts will have a cross-fall breach clause i.e. a breach in one Contract will automatically be classified as a breach of the other contract which will confer on you the right to terminate the other contract at our risk and cost.
6.0 We have read the provisions of following clauses and confirm that the specified stipulations of these clauses are acceptable to us:
(a) ITB 13 Bid Security
(b) GCC 2.14 Governing Law
(c) GCC 5.1 Contractor’s Responsibilities
(d) Appendix I to SCC Terms of Payment
(e) GCC 8.3 Performance Security
(f) GCC 6 Taxes and Duties
(g) GCC 40 Defect Liability
(h) GCC 59 Arbitration
(i) GCC 60 Conciliation
(j) Appendix 2 to SCC Price Adjustment
Further we understand that deviation taken in any of the above clauses by us may make our bid non-responsive as per provision of bidding documents and be rejected by you.
7.0 We undertake, if our bid is accepted, to commence the work immediately upon your Notification of Award to us, and to achieve the delivery of goods and related services within the time stated in the Bidding Documents.
8.0 If our bid is accepted, we undertake to provide a Performance Security in the form and amounts, and within the times specified in the Bidding Documents.
9.0 We agree to abide by this bid for a period of six (06) months from the date fixed for opening of bids as stipulated in the Bidding Documents, and it shall remain binding upon us and may be accepted by you at any time before the expiration of that period.
10.0 Until a formal Contract is prepared and executed between us, this bid, together with your written acceptance thereof in the form of your Notification of Award shall constitute a binding contract between us.
11.0 We understand that you are not bound to accept the lowest or any bid you may receive.
12.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions. 2
13.0 We are a Micro and Small Enterprise (MSE) registered with , a designated Authority of GoI under the Public Procurement Policy for MSEs order 2012, Notification dated 01/06/2020 and 26/06/2020 read in conjuction with related notifications issued from time to time for such enterprises. 2
14.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of 0
Date : -- Printed Name :
Place : Designation :
In case of bid from a Joint Venture, name & designation of representative of JV partner is to be provided and Bid Form is also to be signed by him
#REF! Printed Name :
#REF! Designation :
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
पावर ग्रिड कारपोरेशन ऑफ इंडिया लिमिटेड
POWER GRID CORPORATION OF INDIA LTD.
WRTS-II,RHQ,VADODARA
BILL OF QUANTITIES FOR Construction of New Control Room Building at 400/220 kV Dehgam S/s
Name of Package: Construction of New Control Room Building, at 400/220kV Dehgam Sub-Station.
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Sole Bidder) : To:
Name : Contract Services
Address : Power Grid Corporation of India Ltd.,
Western Region Transmission syatem -II
Plot No. 54, Near Riya revati resort ,
Sama - savli road, vadodara-390008
Installation Charges- Sch 3B1:-Schedule Items for Construction of New Control Room Building at 400/220 kV Dehgam S/s
Sl. No. Activity Header / Substation Name Service Code SAC Whether SAC in column ‘3’ is confirmed. If not indicate applicable the SAC # Rate of GST applicable ( in %) Description (DSR'23Items- Civil Works) Unit Quantity Unit Erection Charges Modified Rate of DSR 2023 using correction factor Unit Erection Charges excluding GST Total Erection Charges excl GST Total Tax GST @ 18% Total Erection Charges incl. GST
(Service Accounting Codes)
PART -A : Schedule Items as per DSR 2023 (Civil works)
1 400/220 kV Dehgam S/s 120000008 995428 18% 1.1 Carriage of materials by mechanical transport including loading, unloading and stacking CuM 87.38 217.55 211.68 179.39 15674.70 2821.45 18496.15
1.1.2 EARTH upto 1.00 km.
2 400/220 kV Dehgam S/s 120000345 995433 18% 2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. CuM 1107.14 177.50 172.71 146.36 162042.96 29167.73 191210.69
2.6.1 All kind of soil
3 400/220 kV Dehgam S/s 120000349 995433 18% 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. CuM 65.49 260.30 253.27 214.64 14056.34 2530.14 16586.48
2.8.1 All kind of soil
4 400/220 kV Dehgam S/s 2.10 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc and disposing of the suplus excavated soil as directed, within a lead of 50m:
120000354 995433 18% 2.10.1.2 Pipes, cables etc exceeding 80 mm dia but not exceeding 300mm dia Mtrs 100.00 352.15 342.6420 290.37 29037.45 5226.74 34264.20
5 400/220 kV Dehgam S/s 120000391 995433 18% 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides, of the foundation etc. in layers not exceeding 20 cms in depth, consolidating each deposited layer by ramming and watering, lead upto 50 mtrs and lift upto 1.5 mtrs. CuM 1085.25 196.00 190.7080 161.62 175394.04 31570.93 206964.97
6 400/220 kV Dehgam S/s 120000392 995433 18% 2.26 Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked materials. CuM 588.17 126.80 123.3764 104.56 61496.44 11069.36 72565.80
2.26.1 All kinds of Soil
7 400/220 kV Dehgam S/s 120000394 995433 18% 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. CuM 54.42 2123.75 2066.4088 1751.19 95292.74 17152.69 112445.43
8 400/220 kV Dehgam S/s 0% 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering : All works upto plinth level.
120000442 995454 18% 4.1.8 1:4:8 (1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) CuM 91.00 6812.00 6628.0760 5617.01 511136.45 92004.56 603141.01
9 400/220 kV Dehgam S/s 120000450 995454 18% 4.2 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor,etc., up to floor five level, excluding the cost of centering,shuttering and finishing : CuM 5.00 9895.20 9628.0296 8159.35 40796.74 7343.41 48140.15
4.2.3 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
10 400/220 kV Dehgam S/s 120000456 995457 18% 4.3 Centering and shuttering including strutting, propping etc. and removalof form work for : SqM 81.33 392.15 381.5620 323.36 26298.77 4733.78 31032.55
4.3.1 Foundations, footings, bases for columns Sqm
11 400/220 kV Dehgam S/s 120000470 995454 18% 4.10 Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). SqM 65.12 410.85 399.7571 338.78 22061.91 3971.14 26033.06
12 400/220 kV Dehgam S/s 120000472 995454 18% 4.12 Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. per bag of 50 kg cement used 16.67 18.15 17.6599 14.97 249.50 44.91 294.41
13 400/220 kV Dehgam S/s 120000473 995454 18% 4.13 Providing & Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. SqM 65.12 146.15 142.2040 120.51 7847.99 1412.64 9260.63
14 400/220 kV Dehgam S/s 120000477 995454 18% 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. SqM 71.25 749.30 729.0689 617.86 44022.17 7923.99 51946.16
15 400/220 kV Dehgam S/s 0.00% 5.9 Centring and shuttering including strutting propping etc. and removal of form for :
A 400/220 kV Dehgam S/s 120000499 995457 18% 5.9.1 Foundations, footings, bases of columns etc. for mass concrete. SqM 90.39 392.15 381.5620 323.36 29228.29 5261.09 34489.38
B 400/220 kV Dehgam S/s 120000500 995457 18% 5.9.2 Walls (any thickness) including attached pilasters, buttresses, plinth & string courses etc. SqM 10.00 842.50 819.7525 694.71 6947.06 1250.47 8197.53
C 400/220 kV Dehgam S/s 120000501 995457 18% 5.9.3 Suspended floors, roofs, landings, balconies and access platform SqM 1039.01 927.25 902.2143 764.59 794411.68 142994.10 937405.78
D 400/220 kV Dehgam S/s 120000503 995457 18% 5.9.5 Lintels, beams, plinth beams, girders, bressumers & cantilevers SqM 1286.85 736.40 716.5172 607.22 781399.65 140651.94 922051.59
E 400/220 kV Dehgam S/s 120000504 995457 18% 5.9.6 Columns, pillars, piers abutments posts & struts SqM 677.34 961.30 935.3449 792.67 536899.86 96641.98 633541.84
F 400/220 kV Dehgam S/s 120000505 995457 18% 5.9.7 Stairs (excluding landings) except spiral staircases. SqM 44.34 764.95 744.2964 630.76 27967.88 5034.22 33002.10
G 400/220 kV Dehgam S/s 120000511 995457 18% 5.9.13 Vertical and horizontal fins individually or forming box louvers,bands,facias,and eaves boards. SqM 20.00 1296.70 1261.6891 1069.23 21384.56 3849.22 25233.78
H 400/220 kV Dehgam S/s 5.9.14 Extra for shuttering in circular work (20% of respective centering and shuttering items) SqM 5.50 192.26 187.0690 158.53 871.14 156.81 1027.94
I 400/220 kV Dehgam S/s 120000513 995457 18% 5.9.15 Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like SqM 20.00 392.15 381.5620 323.36 6467.15 1164.09 7631.24
J 400/220 kV Dehgam S/s 120000513 995457 18% 5.9.16.1 Edges of slabs and breaks in floors and walls Sq.m. 41.25 208.55 202.9192 171.97 7093.57 1276.84 8370.41
Under 20 cm wide
L 400/220 kV Dehgam S/s 120000518 995457 18% 5.9.19 Weather shade, chajjas, corbels etc. including edges. SqM 30.00 951.10 925.4203 784.25 23527.63 4234.97 27762.61
16 400/220 kV Dehgam S/s 5.11 Extra for additional height in centring &, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels over a height of 3.5 m for every additional height of 1m or part thereof (Plan area to be measured) Sq.m.
120000518 995457 18% 5.11.1 Suspended floors, roofs, landings, beams and balconies (Plan area to be measured) 45.84 384.30 373.9239 316.88 14525.29 2614.55 17139.84
17 400/220 kV Dehgam S/s 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Kg
18% 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more Kg 18358.13 107.85 104.9381 88.93 1632598.88 293867.80 1926466.68
18 400/220 kV Dehgam S/s 5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Kg
18% 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more Kg 31106.53 107.85 104.9381 88.93 2766320.99 497937.78 3264258.77
19 400/220 kV Dehgam S/s 120000560 995478 18% 5.30 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. Metre 227.47 78.40 76.2832 64.65 14705.07 2646.91 17351.99
20 400/220 kV Dehgam S/s 5.33 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work;using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
A 400/220 kV Dehgam S/s 120003381 995421 18% 5.33.1.1 Concrete of M25 grade with minimum cement content of 350 kg /cum upto plinth level CuM 177.20 9504.75 9248.1218 7837.39 1388810.49 249985.89 1638796.38
B 400/220 kV Dehgam S/s 120003383 995421 18% 5.33.2.1 Concrete of M25 grade with minimum cement content of 350 kg /cum above plinth level and upto floor V level CuM 282.96 9860.40 9594.1692 8130.65 2300635.21 414114.34 2714749.55
21 400/220 kV Dehgam S/s 120000568 995454 18% 5.35 Add for using extra cement in the items of design mix over and above the specified cement content therein. Quintal 151.85 733.50 713.6955 604.83 91844.91 16532.08 108377.00
22 400/220 kV Dehgam S/s 120000601 995456 18% 6.1 Brick work with common burnt clay F .P .S. (non modular) bricks of class designation 7.5 in foundation and plinth in: CuM 6.56 7132.25 6939.6793 5881.08 38550.51 6939.09 45489.60
6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand)
23 400/220 kV Dehgam S/s 120000607 995456 18% 6.4 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : CuM 273.26 9105.95 8860.0894 7508.55 2051815.54 369326.80 2421142.34
6.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand)
24 400/220 kV Dehgam S/s 120000618 995456 18% 6.13 Half brick masonry with common burnt clay F .P .S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. SqM 523.46 1123.80 1093.4574 926.66 485066.97 87312.05 572379.02
6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)
25 400/220 kV Dehgam S/s 120000620 995456 18% 6.15 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry . SqM 523.46 104.80 101.9704 86.42 45234.93 8142.29 53377.22
26 400/220 kV Dehgam S/s 8.2 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
A 400/220 kV Dehgam S/s 8.2.1 Rajnagar plain White marble/Udaipur green marble/Zebra black marble
B 400/220 kV Dehgam S/s 8.2.2 Granite of any colour and shade
27 400/220 kV Dehgam S/s 120000742 995474 18% 8.4 Extra for fixing marble /granite stone, over and above corresponding basic,item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. Metre 20.00 568.55 553.20 468.81 9376.26 1687.73 11063.98
28 400/220 kV Dehgam S/s 120000743 995474 18% 8.5 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. Each 7.00 978.70 952.28 807.01 5649.09 1016.84 6665.93
29 400/220 kV Dehgam S/s 120000743 995474 18% 8.31 Providing and Fixing 1st quality ceramic glazed wall tiles conforming to IS 15622(thickness to bespecified by the manufacturer) of approved make in all colours, shades except burgundy, bottle-green, black of any size as approved by the Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of Cement mortar 1:3 (1 Cement:3 Coarse Sand) and jointing with grey cement slurry @ 3.3 kg per sq m including pointing in white cement mixed with pigment of matching shade complete. Sq.m. 127.95 1267.95 1233.72 1045.52 133775.10 24079.52 157854.62
30 400/220 kV Dehgam S/s 9.71 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : Each
31 400/220 kV Dehgam S/s 9.74 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :
32 400/220 kV Dehgam S/s 9.75 Providing and fixing bright finished brass door latch with necessary screws etc. complete :.
33 400/220 kV Dehgam S/s 120000962 995476 18% 9.87 Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete : Each 28.00 139.10 135.34 114.70 3211.56 578.08 3789.64
34 400/220 kV Dehgam S/s 120000965 995476 18% 9.88 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Each 12.00 998.35 971.39 823.22 9878.59 1778.15 11656.73
35 400/220 kV Dehgam S/s 9.92 Providing and fixing chromium plated brass handles with necessary screws etc. complete: Each
36 400/220 kV Dehgam S/s 120000971 995476 18% 9.96 Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with nuts and screws etc. complete.
37 400/220 kV Dehgam S/s 9.97 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete
38 400/220 kV Dehgam S/s 9.100 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
39 400/220 kV Dehgam S/s 120001000 995476 18% 9.101 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour & shade with necessary screws etc. complete Each 25.00 72.35 70.40 59.66 1491.45 268.46 1759.91
9.101.2 Twin rubber stopper
40 400/220 kV Dehgam S/s 9.117 Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin-charge Metre
41 400/220 kV Dehgam S/s 120001019 995476 18% 9.136 Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately). Metre 48.00 1709.25 1663.10 1409.41 67651.54 12177.28 79828.81
42 400/220 kV Dehgam S/s 120001021 995476 18% 9.137 Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately). Sqm 32.49 7533.20 7329.80 6211.70 201818.07 36327.25 238145.32
43 400/220 kV Dehgam S/s 120001028 995476 18% 9.138 Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 60 minutes of fire resistance both integrity & radiation control (EW60) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm. Sqm 0.44 40405.55 39314.60 33317.46 14576.39 2623.75 17200.14
44 400/220 kV Dehgam S/s 120001036 995476 18% 9.139 Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. Each 7.00 8366.15 8140.26 6898.53 48289.70 8692.15 56981.85
400/220 kV Dehgam S/s
45 9.147 Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3 (ii) Sites with structure height more than 20m for all wind speeds
A 400/220 kV Dehgam S/s 9.147.A1 Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.
18% 9.147.A1.2 Using R3 series with frame (55 mm & above) x (40 mm & above) & sash (30 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every panel along with multi-point locking system (Height upto 1.8m Sqm 49.50 8799.25 8561.67 7255.65 359154.81 64647.87 423802.68
B 400/220 kV Dehgam S/s 9.147.A2 Two track four panels sliding windows with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on three panels along with multi-point locking system, nylon rollers with SS 304 body
18% 9.147.A2.1 Using R3 series with frame (55 mm & above) x (40 mm & above) & sash (30 mm & above) x (55 mm & above) (Height upto 1.8m) Sqm 19.80 7860.35 7648.12 6481.46 128332.87 23099.92 151432.79
C 400/220 kV Dehgam S/s 9.147.B1 Two track two panels sliding door with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on every panel along with multi-point locking system, adjustable nylon rollers with SS 304 body.
18% 9.147.B1.1 Using R3 series with frame (55 mm & above) x (40 mm & above) & sash (30 mm & above) x (74 mm & above). (Height upto 2.5 metre) Sqm 9.75 8106.30 7887.43 6684.26 65171.56 11730.88 76902.44
D 400/220 kV Dehgam S/s 9.147.C1 Fixed window / ventilator without mullion / transom.
18% 9.147.C1.4 Using R4 series with frame (64 mm & above) x (50 mm & above). (Height above 2.5 metre) Sqm 141.05 6032.85 5869.96 4974.54 701659.57 126298.72 827958.29
E 400/220 kV Dehgam S/s 120001044 995476 9.147F1 Casement door single panel with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides.
18% 9.147F1.1 Using R3 series with frame (55 mm & above) x (50 mm & above) & sash (55 mm & above) x (85 mm & above) (Height upto 2.5 metre). Sqm 4.80 12496.05 12158.66 10303.95 49458.94 8902.61 58361.55
46 400/220 kV Dehgam S/s 120001019 995476 18% 10.2 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Kg 2581.67 133.70 130.09 110.25 284618.60 51231.35 335849.94
47 400/220 kV Dehgam S/s 120001147 995476 18% 10.18 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. Each 50.00 220.65 214.69 181.94 9097.14 1637.48 10734.62
48 400/220 kV Dehgam S/s 120001153 995477 10.25 Steel work welded in built up sections / framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc as required
18% 10.25.2 In gratings, frames, guard bars, ladders, railings, brackets, gates and similar works. Kg 1007.72 172.60 167.94 142.32 143420.59 25815.71 169236.30
49 400/220 kV Dehgam S/s 120001153 995477 10.27 Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.
50 400/220 kV Dehgam S/s 120001162 995476 18% 10.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Kgs. 585.29 772.40 751.55 636.90 372770.24 67098.64 439868.88
51 400/220 kV Dehgam S/s 18% 11.5 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. Sqm 182.03 1056.15 1027.63 870.88 158528.91 28535.20 187064.11
52 400/220 kV Dehgam S/s 11.6 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.
53 400/220 kV Dehgam S/s 120001227 995474 18% 11.23 Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : SqM 10.00 2428.60 2363.03 2002.57 20025.66 3604.62 23630.28
11.23.5 Udaipur green marble
54 400/220 kV Dehgam S/s 120001229 995474 18% 11.24 Extra for pre finished nosing to treads of steps of marble stone. Metre 10.00 719.90 700.46 593.61 5936.12 1068.50 7004.63
55 400/220 kV Dehgam S/s 120001230 995474 18% 11.25 Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre . SqM 10.00 851.80 828.80 702.37 7023.74 1264.27 8288.01
56 400/220 kV Dehgam S/s 120001428 995474 18% 11.39 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete SqM 40.38 1330.00 1294.09 1096.69 44285.43 7971.38 52256.80
57 400/220 kV Dehgam S/s 120001251 995474 18% 11.41 Providing and laying vitrified floor tiles in different sizes(thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make in all colours and shades,laid on 20 mm thick cement mortar 1:4(1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. SqM 525.14 1553.45 1511.51 1280.94 672671.66 121080.90 793752.56
11.41.2 Size of tile 600 X 600 mm
58 400/220 kV Dehgam S/s 120001251 995474 18% 11.46 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Sq.m.
59 400/220 kV Dehgam S/s 120001267 995474 18% 11.48 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling /grouting and finishing complete as per direction of Engineer-in-charge. SqM 525.14 309.05 300.71 254.84 133824.18 24088.35 157912.53
11.48.2 Size of Tile 600x600 mm
60 18% 11.50 Deduct for not grouting the joints with white cement and matching pigmenin the items of fixing of vitrified tiles. Sqm -525.14 13.3 12.94 10.97 -5759.14 -1036.64 -6795.78
61 400/220 kV Dehgam S/s 11.56 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Sq.m.
A 18% 11.56.1 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent Sq.m. 10.00 4481.30 4360.30 3695.17 36951.74 6651.31 43603.05
B 18% 11.56.2 Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red Sq.m. 10.00 3071.05 2988.13 2532.31 25323.15 4558.17 29881.32
62 400/220 kV Dehgam S/s 120001318 995453 18% 12.21 Providing gola 75 X 75 mm in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1: 3 ( 1 cement : 3 fine sand) as per standard design:
63 400/220 kV Dehgam S/s 120001319 995453 18% 12.22 Making khurras 45 x 45 cm with average minimum thickness of 5cm cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1mx1mx400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete. Each 17.00 298.25 290.20 245.93 4180.81 752.55 4933.35
64 400/220 kV Dehgam S/s 120001351 995453 18% 12.41 Providing and fixing on wall face unplasticised -Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes.
65 400/220 kV Dehgam S/s 12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
66 400/220 kV Dehgam S/s 120001365 995453 18% 12.43 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised -PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. Each 141.00 371.30 361.27 306.17 43169.29 7770.47 50939.76
67 400/220 kV Dehgam S/s 120001366 995453 18% 12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams. Each 17.00 54.70 53.22 45.10 766.77 138.02 904.79
68 400/220 kV Dehgam S/s 12.52 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. Sqm
18% 12.52.3 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. 292.74795 2215.15 2155.34 1826.56 534721.7328 96249.91 630971.6447
69 400/220 kV Dehgam S/s 18% 12.55 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner Sqm 121.00 1703.95 1657.94 1405.04 170009.45 30601.70 200611.15
70 400/220 kV Dehgam S/s 18.58 Providing and fixing PTMT grating of approved quality and colour.
18% 18.58.2.1 Rectangular type with openable circular lid 18.58.2.1 150 mm nominal size square 100 mm diameter of the inner hinged round grating Each 17.00 196.95 191.63 162.40 2760.81 496.94 3257.75
13.4.2 1:6 (1 cement : 6 coarse sand).
72 400/220 kV Dehgam S/s 120001408 995472 18% 13.5 15 mm cement plaster on rough side of single or half brick masonry wall of mix : Internal walls SqM 401.29 395.35 384.68 326.00 130818.31 23547.30 154365.61
13.5.2 1:6 ( 1 cement : 6 coarse sand)
73 400/220 kV Dehgam S/s 120001415 995472 18% 13.9 Cement plaster 1:3 ( 1cement : 3 coarse sand) finished with a floating coat of neat cement : SqM 163.80 449.55 437.41 370.69 60718.74 10929.37 71648.11
13.9.1 12 mm cement plaster
74 400/220 kV Dehgam S/s 120001418 995472 18% 13.11 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). SqM 1499.22 518.55 504.55 427.58 641041.09 115387.40 756428.48
75 400/220 kV Dehgam S/s 120001423 995472 13.16 6 mm cement plaster of mix :
76 400/220 kV Dehgam S/s 18.00% 13.21 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers per bag of 50kg cement used in the mix 243.77 22.10 21.50 18.22 4442.30 799.61 5241.92
77 400/220 kV Dehgam S/s 18.00% 13.22 Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. Sqm 34.46 87.10 84.75 71.82 2474.94 445.49 2920.43
78 400/220 kV Dehgam S/s 13.23 Extra for plastering on circular work not exceeding 6 m in radius: Sqm
79 400/220 kV Dehgam S/s 120001432 995472 18% 13.24 Extra for plastering done on moulding cornices or architraves including neat finish to line and level: SqM 30.00 713.20 693.94 588.09 17642.63 3175.67 20818.31
A 13.24.1 In one coats
80 400/220 kV Dehgam S/s 18% 13.26 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. Sq.m. 3284.67 262.70 255.61 216.62 711513.48 128072.43 839585.90
81 400/220 kV Dehgam S/s 18% 13.27 Extra for lining out plaster to imitate stone or concrete blocks walling. Sq.m. 1499.22 113.90 110.82 93.92 140805.28 25344.95 166150.23
82 400/220 kV Dehgam S/s 13.45 Finishing walls with textured exterior paint of required shade : Sq.m.
18% 13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm Sq.m. 150.00 223.60 217.56 184.38 27656.29 4978.13 32634.42
83 400/220 kV Dehgam S/s 120001511 995472 18% 13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete SqM 1499.22 156.05 151.84 128.68 192911.89 34724.14 227636.03
84 400/220 kV Dehgam S/s 120001467 995473 18% 13.47 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: SqM 1499.22 171.10 166.48 141.09 211516.98 38073.06 249590.04
13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.9 litre/10 sqm)
85 400/220 kV Dehgam S/s 13.50 Applying priming coat:
18% 13.50.3 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works Sq.m. 45.00 67.40 65.58 55.58 2500.94 450.17 2951.11
86 400/220 kV Dehgam S/s 120001517 995473 18% 13.83 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. SqM 3284.67 142.80 138.94 117.75 386768.65 69618.36 456387.01
13.83.2 Two coats
87 400/220 kV Dehgam S/s 13.85 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.
120001522 995473 18% 13.85.3 With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre SqM 3284.67 73.95 71.95 60.98 200290.91 36052.36 236343.27
88 400/220 kV Dehgam S/s 120001491 995473 18% 13.62 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : SqM 45.00 226.25 220.14 186.56 8395.22 1511.14 9906.36
13.62.1 13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
89 400/220 kV Dehgam S/s 120001838 995421 18% 16.68 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. SqM 30.00 972 945.76 801.49 24044.64 4328.04 28372.68
90 400/220 kV Dehgam S/s 18% 16.88 Providing and laying matt finished vitrified tile of size 100x100x16mm having water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in out door floors such as footpath, court yard multi models etc., laid on 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as direction of Engineer-in-Charge. Sq.m. 20.00 2159.85 2101.53 1780.96 35619.22 6411.46 42030.68
91 400/220 kV Dehgam S/s 120001868 995478 18% 16.91 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. Sqm 20.00 1045.65 1017.42 862.22 17244.36 3103.99 20348.35
16.91.1 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
92 400/220 kV Dehgam S/s 120003387 995421 18% 8.10 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. sq.m 2.00 4051.85 3942.45 3341.06 6682.12 1202.78 7884.90
8.10.2 Granite Stone of approved shade
93 400/220 kV Dehgam S/s 120001902 995478 18% 17.10 Providing and fixing stainless steel A ISI 304(18/8) kitchen sink as per IS:13983 with CI brackets and stainless steel plug 40 mm, including painting of fittings & brackets cutting and making good the walls wherever required Each 1.00 6917.20 6730.44 5703.76 5703.76 1026.68 6730.44
17.10.1 Kitchen sink with drain board
17.10.1.4 Size 510 x 1040 bowl depth 178 mm
94 400/220 kV Dehgam S/s 17.12 Providing and fixing draining board with C.I. brackets including painting of brackets, cutting and making good the walls wherever required :
120003125 995478 18% 17.12.1 White glazed fire clay draining board of size 600x450x 25 mm Each 1.00 1579.65 1537.00 1302.54 1302.54 234.46 1537.00
95 400/220 kV Dehgam S/s 17.28 Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete
17.28.1 Semi Rigid pipe
96 400/220 kV Dehgam S/s 120001940 995478 18% 17.30 Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design. Each 8.00 55.65 54.15 45.89 367.10 66.08 433.18
97 400/220 kV Dehgam S/s 120001941 995478 18% 17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Each 8.00 1607.95 1564.54 1325.88 10607.02 1909.26 12516.28
98 400/220 kV Dehgam S/s 120002062 995478 18% 17.78 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover , and cistern fittings, nuts, bolts and gasket etc complete. Each 6.00 14999.15 14594.17 12367.94 74207.66 13357.38 87565.04
99 400/220 kV Dehgam S/s 120001947 995478 18% 17.34 Providing and fixing toilet paper holder :
100 400/220 kV Dehgam S/s 120002049 995478 18% 17.69 Providing and fixing PTMT Waste Coupling for wash basin and sink,of approved quality and colour. Each 6.00 122.40 119.10 100.93 605.57 109.00 714.57
17.69.2 Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms
101 400/220 kV Dehgam S/s 120002052 995478 18% 17.80 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. Each 3.00 7979.20 7763.76 6579.46 19738.38 3552.91 23291.28
102 400/220 kV Dehgam S/s 0.00% 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
103 400/220 kV Dehgam S/s 0.00% 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
104 400/220 kV Dehgam S/s 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work
105 400/220 kV Dehgam S/s 18.12 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work meter
106 400/220 kV Dehgam S/s 18.13 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
107 400/220 kV Dehgam S/s 18.00% 18.14 Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). Each 5.00 812.30 790.37 669.80 3349.02 602.82 3951.84
108 400/220 kV Dehgam S/s 18.17 Providing and fixing gun metal gate valve with CI wheel of approved quality (screwed end)
109 400/220 kV Dehgam S/s 120002153 995424 18% 18.18 Providing and fixing ball valve (brass) of approved quality High or low pressure with plastic floats complete. Each 2.00 464.05 451.52 382.64 765.29 137.75 903.04
18.18.3 25 mm nominal bore
110 400/220 kV Dehgam S/s 18.19 Providing and fixing gun metal non-return valve of approved quality (screwed end)
18.19.1 25 mm nominal bore
111 400/220 kV Dehgam S/s 18.19 Providing and fixing gun metal non- return valve of approved quality (screwed end) :
A 400/220 kV Dehgam S/s 18.19.3 40 mm nominal bore
B 400/220 kV Dehgam S/s 18.19.4 50 mm nominal bore
C 400/220 kV Dehgam S/s 18.19.5 65 mm nominal bore
D 400/220 kV Dehgam S/s 18.19.6 80 mm nominal bore
112 400/220 kV Dehgam S/s 120002171 995424 18% 18.21 Providing and fixing uplasticised PVC connection pipe with brass unions : Each 2.00 97.75 95.11 80.60 161.20 29.02 190.22
18.21.2 45 cm length
18.21.2.1 15 mm nominal bore
113 400/220 kV Dehgam S/s 120002228 995424 18% 18.32 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : Each 10.00 1992.60 1938.80 1643.05 16430.51 2957.49 19388.00
18.32.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
114 400/220 kV Dehgam S/s 18.34 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
120003227 995424 18% 18.34.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 each 3.00 18896.70 18386.49 15581.77 46745.31 8414.16 55159.47
115 400/220 kV Dehgam S/s 18.40 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : Metre
116 400/220 kV Dehgam S/s 18.41 Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : Metre
117 400/220 kV Dehgam S/s 120003227 995424 18% 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. per litre 2000.00 11 10.70 9.07 18140.68 3265.32 21406.00
118 400/220 kV Dehgam S/s 120002287 995424 18% 18.49 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
119 400/220 kV Dehgam S/s 120002141 995424 18% 18.51 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. Each 8.00 798.95 777.38 658.80 5270.36 948.67 6219.03
18.51.1 15 mm nominal bore
120 400/220 kV Dehgam S/s 120002290 995424 18% 18.52 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 Each 10.00 670.45 652.35 552.84 5528.37 995.11 6523.48
18.52.1 15 mm nominal bore
121 400/220 kV Dehgam S/s 120002291 995424 18% 18.53 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 Each 56.00 574.30 558.79 473.55 26519.03 4773.43 31292.46
18.53.1 15mm nominal bore
122 400/220 kV Dehgam S/s 120002305 995424 18% 18.58 Providing and fixing PTMT grating of approved quality and colour Each 12.00 196.95 191.63 162.40 1948.80 350.78 2299.59
18.58.2 Rectangular tupe with openable circular lid
18.58.2.1 150 mm nominal size square 100mm diametre of the inner hinged round grating
123 400/220 kV Dehgam S/s 19.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)all around SW pipes including bed concrete as per standard design.
124 400/220 kV Dehgam S/s 120002642 995424 18% 19.4 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : Each 4.00 2802.15 2726.49 2310.59 9242.35 1663.62 10905.97
19.4.3 180x150 mm size P type
19.4.3.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
125 400/220 kV Dehgam S/s 19.6 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
126 400/220 kV Dehgam S/s 120002665 995424 18% 19.7 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Each 10.00 12770.55 12425.75 10530.29 105302.93 18954.53 124257.45
19.7.1 Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total wt. of cover and frame to be not less than 38 kg. (wt. of the cover 23 kg and wt. of the frame 15 kg.)
19.7.1.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
19.8.1 Size 90 x 80 cm
19.8.1.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
128 400/220 kV Dehgam S/s 120002324 995424 18% 19.16 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. Each 10.00 553.70 538.75 456.57 4565.68 821.82 5387.50
129 400/220 kV Dehgam S/s 19.35 Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete Metre
127 400/220 kV Dehgam S/s 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
21.1.1.3 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)
B 21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
120002795 995476 18% 21.1.2.3 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) Kg 25.00 643.45 626.08 530.57 13264.34 2387.58 15651.92
C 400/220 kV Dehgam S/s 120002799 995476 18% 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): sq.m 147.65 1505.25 1464.61 1241.19 183262.21 32987.20 216249.41
21.3.2 With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm
18% 21.3.3 With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) Sqm 147.65 1685.40 1639.89 1389.74 205195.24 36935.14 242130.38
130 400/220 kV Dehgam S/s 120002807 995476 18% 21.8 Filling the gap in between aluminium frame and adjacent RCC/Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in Charge complete. Metre 262.70 96.75 94.14 79.78 20957.62 3772.37 24729.99
21.8.1 Up to 5mm depth and 5mm width
131 400/220 kV Dehgam S/s 120002823 995476 18% 21.15 Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. Each 306.00 95.10 92.53 78.42 23995.66 4319.22 28314.88
21.15.3 Polyester powder coated minimum thickness 50 micron aluminium
132 400/220 kV Dehgam S/s 18% 21.18 Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc. to be paid separately) Sqm 22.71 5325.90 5182.10 4391.61 99733.48 17952.03 117685.51
133 400/220 kV Dehgam S/s 120002835 995453 18% 22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) SqM 232.89 617.05 600.39 508.80 118496.16 21329.31 139825.47
134 400/220 kV Dehgam S/s 22.7 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies terraces etc. consisting of following operations. (a) Applying a slurry coat of neat cement using 2.75Kg/sq.m. of cement admixed with water proofing compound conforming to IS:2645 and approved by Engneer in charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.
(b)Laying brick bats with mortar using broken bricks/brick bats 25mm to 1115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineer in charge over 20mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineer in charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of the junctions of walls and slabs.
(c )After two days of proper curing applying a second coat of cement slurry using 2.75 kg/sq.m. of cement admixed with water proofing compound conforming to IS:2645 and approved by the Engineer in charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order & as directed and specified by the Engineer-in-charge.
400/220 kV Dehgam S/s 120002837 995453 18% 22.7.1 With average thickness of 120 mm and minimum thickness at Khurra as 65mm SqM 450.00 1684.60 1639.12 1389.08 625086.53 112515.58 737602.11
135 400/220 kV Dehgam S/s 26.86 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door / window / clerestory windows & desertory other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
136 400/220 kV Dehgam S/s 26.88 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/ mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
Total of Schedule Items as per DSR'23 ₹ 25,886,527.61 ₹ 4,659,574.97 ₹ 30,546,102.58
Add percentage (%) above/below +/- on DSR 2023 Rates (to be quoted by contractor) 2.00% 2.00%
Add Amount above/below +/- on the amount for DSR Items as per quoted percentage 517730.55 93191.50
Total of Schedule Items Part IIIA ₹ 26,404,258.17
Total Tax ₹ 4,752,766.47
Date: #REF! Name: #REF!
Place: #REF! Designation: #REF!
पावर ग्रिड कारपोरेशन ऑफ इंडिया लिमिटेड
POWER GRID CORPORATION OF INDIA LTD.
WRTS-II,RHQ,VADODARA
BILL OF QUANTITIES FOR Construction of New Control Room Building at 400/220 kV Dehgam S/s
Name of Package: Construction of New Control Room Building, at 400/220kV Dehgam Sub-Station.
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Sole Bidder) : To:
Name : Contract Services
Address : Power Grid Corporation of India Ltd.,
Western Region Transmission syatem -II
Plot No. 54, Near Riya revati resort ,
Sama - savli road, vadodara-390008
Installation Charges- Sch 3B: Non-Schedule Items for Construction of New Control Room Building at 400/220 kV Dehgam S/s
Sl. No. Activity Header / Substation Name Activity Description SAC Rate of GST applicable ( in %) Description Unit Quantity Unit Erection Charges Total Erection Charges Total Tax GST
(Service Accounting Codes)
Part B: Non - Schedule Items (Civil works)
1 400/220 kV Dehgam S/s Non-Schedule Item 998531 18% NS-1 : Supply, Diluting and injecting chemical emulsion (excluding of the cost of the chemical emulsion) for PRE-CONSTRUCTIONAL ANTI-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (Plinth area of the building at ground floor only shall be measured for payment). Chlorpyriphos / Lindane Emulsifiable concentrate 20% with 1% concentration. SqM 450.00 0.00 0.00
2 400/220 kV Dehgam S/s Non-Schedule Item 995411 18% NS-2 : Providing & fixing rubber shock absorbers of minimum 25mm dia and 40mm length to be fixed on back side of door including screws etc. all complete. Each 8.00 0.00 0.00
3 400/220 kV Dehgam S/s Non-Schedule Item 995428 18% NS-3: Providing and placing cinder/brick bat filling to the sunk floors in toilets/kitchen sunks, well compacted carefully by hand beating to required slopes including consolidation, curing, (mix shall be one part of cement mortar 4 parts of Cinder/brickbat finishing the same with the cement mortor 1:4 (1cement:4 coarse sand) by adding water proofing compound as per manufacturers recommendations including providing 25mm dia PVC drain pipe of required length. For toilet and Kitchen sunkun portions. CuM 14.90 0.00 0.00
4 400/220 kV Dehgam S/s Non-Schedule Item NS-4 : Providing, fixing , laying, testing & commissioning (Concealed/surface mounted or underground) uPVC SWR Rigid pipes confirming to IS 13592-1992 of PRICE/SUPREME/FINOLEX or equivalent make of working pressure 6kg/sq.cm for drainage line including necessary fittings such as couplers, bends, tees, cross tees, cowls, clamps, rubber packing ring etc. confirming to DIN 19561, DIN 19534, IS 14735-99, IS-5382, joining with adhessive solvent cement including cost of jointing materials and all other necessary fixtures, fitting, air and water tight testing of the line etc. complete at all levels. (Centre line length of completed pipe line shall be measured for payment purpose)
A 400/220 kV Dehgam S/s Non-Schedule Item 995428 18% NS-4A : 40mm outer dia. Metre 30.00 0.00 0.00
B 400/220 kV Dehgam S/s Non-Schedule Item 995416 18% NS-4B : 75mm outer dia. Metre 100.00 0.00 0.00
C 400/220 kV Dehgam S/s Non-Schedule Item 995478 18% NS-4C : 110mm outer dia. Metre 95.00 0.00 0.00
5 400/220 kV Dehgam S/s Non-Schedule Item 995424 18% NS-5 : Providing, fixing, testing and commissioning uPVC SWR Nahani trap, plain floor trap/ Multi floor trap with strainer/top cover etc. confirming to DIN 19531, DIN 19534, IS 14735-99, IS-5382 of 110 mm dia inlet and 75 mm outlet nominal dia. including fixing PVC reducer of 110mm dia. to 75 mm dia. and jointing with adhessive solvent cement including cost of cutting and making good the walls and floors at all levels etc. complete. Each 16.00 0.00 0.00
6 400/220 kV Dehgam S/s Non-Schedule Item NS-6 : Providing & fixing Hindware make or equivalent bathroom accessories including cutting wall/making holes and making good the surface with the same finish as directed by the Engineer in charge.
A 400/220 kV Dehgam S/s Non-Schedule Item 995424 18% NS-6A: CP brass high flow single lever concealed diverter with body and plate for bath and shower system equivalent to kohler make K-72329IN-4FP-CP or Jaquar make FUS-CHR-29227 Each 1.00 0.00 0.00
B 400/220 kV Dehgam S/s Non-Schedule Item 995424 18% NS-6B CP brass hand shower (Health faucet) for WC/EWC system -Jaquar ALD-CHR-573 or kohler make K-12925IN-CP Each 6.00 0.00 0.00
400/220 kV Dehgam S/s Non-Schedule Item 995424 18% NS 6C CP Concealed flush valve 32 mm of make Jaquar FLV-CHR-1095 or equivalent make as approved complete. Each 6.00 0.00 0.00
7 400/220 kV Dehgam S/s Non-Schedule Item 995472 18% NS-7 Forming groove of uniform size in the external plaster surface as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge :
20 mm wide and 6 mm deep groove metre 750.00 0.00 0.00
8 400/220 kV Dehgam S/s Non-Schedule Item 995468 18% NS-8 Providing and fixing C.P. brass towel ring of make kohler cat no- 17528T-CP or Jaquar Continental: ACN-CHR-1121N or equivalent make fixed with PVC cleats and brass screws including cutting and making good the walls wherever required complete as directed by Engineer-in-charge. Each 6.00 0.00 0.00
9 400/220 kV Dehgam S/s Non-Schedule Item 995411 18% NS-9 Providing and Fixing Towel rack with single rail of make Jaquar -Cat No: AHS-CHR-1581 or ,kohler cat no- 17529T-CP or equivalent as approved with Rawl Plugs and brass screws complete as directed by Engineer-in-charge. Each 6.00 0.00 0.00
10 400/220 kV Dehgam S/s Non-Schedule Item 995415 18% NS-10 Providing and fixing liquid soap dispenser horizontal /vertical matt finish with simple push lever of make Jaquar ACN-CHR-1137N or Kohler cat K -10712D-CP or equivalent as approved including cutting and making good the walls, wherever required complete as directed by Engineer-in-charge. Each 6.00 0.00 0.00
11 400/220 kV Dehgam S/s Non-Schedule Item 995479 18% NS-11 Providing and Fixing C.P. brass Central Hole basin mixer without pop up waste system of make Jaquar Model: CON-CHR-167KNB or kohler cat no- 16027IN-4ND-CP or equivalent make as approved with 450mm long copper pipe and brass nuts including cutting and making good the walls wherever required complete as directed by Engineer-in-charge. Each 6.00 0.00 0.00
12 400/220 kV Dehgam S/s Non-Schedule Item 995416 18% NS-12 Providing and Fixing Over head Rose shower with revolving joint (with body rotation), 115 mm long shower arm of make Jaquar Cat No: OHS-CHR-1989 or kohler cat no- 16356IN-A-CP or equivalent make as approved complete as directed by Engineer-in-charge Each 1.00 0.00 0.00
13 400/220 kV Dehgam S/s Non-Schedule Item 995411 18% NS-13 Providing and Fixing Soap dish of make Jaquar Continental ACN-CHR-1131 N or kohler cat no- 17524T-CP or equivalent make as approved with PVC / Wooden plugs and screws including making good the walls wherever required complete as directed by Engineer-in-charge. Each 6.00 0.00 0.00
14 400/220 kV Dehgam S/s Non-Schedule Item 995468 18% NS-14 Providing and fixing 6mm thick Clear mirror with bevelled edge on the wall over 6mm thick polycorbonate sheet with ss screw / stud, machine cut in required size, approved shade & colour etc. complete with all respect at all levels as directed by Engineer-in-charge. (Sample of Mirror shall be got approved from Engineer-in-Charge). Each 7.00 0.00 0.00
15 400/220 kV Dehgam S/s Non-Schedule Item 995424 18% NS-15 Providing and Fixing 32mm CP Brass bottle trap complete with 250 mm long wall connecting pipe of Jaquar ALD-CHR-769 B or kohler cat no- 16407IN-CP or equivalent make as approved of size including CP Wall flange complete as directed by Engineer-in-charge. Each 7.00 0.00 0.00
16 400/220 kV Dehgam S/s Non-Schedule Item 995411 18% NS-16 Providing and fixing white color vitreous China oval shape, under counter wash basin of make of Kohler cat. no. 2211 IN-O or jaquar FLS-WHT-0401 or equivalent as approved of 32mm dia outlet with CP Brass connection, Rubber adopter for waste connection and CI Brackets etc including cutting and making good the walls wherever required complete as per direction of engineer-in-charge. Each 7.00 0.00 0.00
17 400/220 kV Dehgam S/s Non-Schedule Item 995476 18% NS-17 Extra for providing frosted glass panes 5 mm thick instead of ordinary float glass panes 5 mm thick in alkuminium doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). SqM 10.00 0.00 0.00
18 400/220 kV Dehgam S/s Non-Schedule Item 995412 18% NS-18 : Supply and filling of good quality moorum under floor in layers not exceeding 20 cms in depth, consolidating each deposited layer by ramming and watering, consolidating and dressing complete. (Measurement shall be based on compacted volume) Cum 45.00 0.00 0.00
19 400/220 kV Dehgam S/s Non-Schedule Item 995428 18% NS-19 Supplying, filling and compacting stone boulders mixed with sand under foundations, roads, cable trenches, drains etc in layers not exceeding 250mm thickness including ramming, watering, compacting etc.(DSR Item No.16.3,16.4,16.3.8) Cum 63.75 0.00 0.00
20 400/220 kV Dehgam S/s Non-Schedule Item 18% NS-20 Providing and fixing Door handles satin finish 25mm x 600mm long Dorma/ozon/Crif make including the cost of all material, labour, transportation, taxes, incidentals etc. as per the directions and instructions of Engineer-in-Charge Each 16.00 0.00 0.00
21 400/220 kV Dehgam S/s Non-Schedule Item 18% NS-21 Door lock satin finish Dorma/ozon/Crif make including the cost of all material, labour, transportation, taxes, incidentals etc. as per the directions and instructions of Engineer-in-Charge Each 16.00 0.00 0.00
Total for Non-Schedule Items (Schedule II) ₹ 0.00 ₹ 0.00
# In case the bidder leaves the cell for confirmation of the SAC and/or GST rate “blank”, the SAC and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date : #REF! Printed Name : #REF!
Place : #REF! Designation : #REF!
पावर ग्रिड कारपोरेशन ऑफ इंडिया लिमिटेड
POWER GRID CORPORATION OF INDIA LTD.
WRTS-II,RHQ,VADODARA
Name of Package: Construction of New Control Room Building at 400/220kV Dehgam Sub-Station.
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Sole Bidder) : To:
Name : Contract Services
Address : Power Grid Corporation of India Ltd.,
Western Region Transmission syatem -II
Plot No. 54, Near Riya revati resort ,
Sama - savli road, vadodara-390008
Installation Charges- Sch 3C: Schedule Items Electrical works for Construction of New Control Room Building at 400/220kV Dehgam Sub-Station.
Sl. No. DSR (E&M 2025 Item No. SAC(Service Accounting Codes) DESCRIPTION OF ITEMS UNIT Total Quantity Rate (Rs.) Deduction of GST factor considered in DSR Unit Charges excluding GST Amount (Rs.) Total Tax GST @ 18% Total Charges incl. GST
SUB HEAD -I: WIRING
1 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
2 1.5 Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed steel conduit alongwith 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required. Meter 1200 480 0.18 0.00 0.00 0.00
3 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
4 1.11 Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Point 8 1803 0.18 0.00 0.00 0.00
5 1.17 Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
6 1.20 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
7 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required
8 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Each 12 402 0.18 0.00 0.00 0.00
9 1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
10 1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1.24.3 3 pin 5/6 A socket outlet Each 48 136 0.18 0.00 0.00 0.00
11 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. Each 55 659 0.18 0.00 0.00 0.00
12 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. Each 18 545 0.18 0.00 0.00 0.00
SUB HEAD -II: SUB MAIN
13 1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire Meter 1200 373 0.18 0.00 0.00 0.00
1.14.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire Meter 700 482 0.18 0.00 0.00 0.00
1.14.5 2 X 10 sq. mm + 1 X 6 sq. mm earth wire Meter 600 621 0.18 0.00 0.00 0.00
SUB HEAD -III: MCB'S AND MAIN DISTRIBUTION BOARDS
14 1.22 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
1.22.1 75 mm X 75 mm X 60 mm deep metal box Each 48 213 0.18 0.00 0.00 0.00
15 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.10.5 Triple pole and neutral Each 12 1301 0.18 0.00 0.00 0.00
16 2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required. Each 24 1258 0.18 0.00 0.00 0.00
17 2.3.4 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator), 16 way Double door Each 2 3367 0.18 0.00 0.00 0.00
18 2.4.3 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).8 way (4 + 24), Double door Each 1 6337 0.18 0.00 0.00 0.00
19 2.5.3 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)(12 way (4 + 36), Double door ). Each 1 13512 0.18 0.00 0.00 0.00
20 2.14 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
21 2.15 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
SUB HEAD -IV: Lighting Fixtures
22 8.1 LED Down lighter (SMD Type) (System lumen Unit Rate efficacy ≥ 105 < 120 lm/Watt ) Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
23 LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)
SUB HEAD -V: EARTHING AND LIGHTNING PROTECTION
24 5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Set 2 15004 0.18 0.00 0.00 0.00
25 5.10 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. Meter 150 1638 0.18 0.00 0.00 0.00
SUB HEAD -VI: TELEPHONE
26 1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1.24.6 Telephone socket outlet Each 48 168 0.18 0.00 0.00 0.00
27 39.16 Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required. Each 180 9 0.18 0.00 0.00 0.00
28 39.17 Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required.
SUB HEAD-VII: AIR CONDITIONING SYSTEM AND FANS
29 32.2 HI - WALL SPLIT SYSTEMS : Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). 0.00
32.2.4 2.0 TR with 5 Star BEE Rating Each 24 57396 0.18 0.00 0.00 0.00
30 9.2 Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
9.2.4 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) Each 12 2737 0.18 0.00 0.00 0.00
Installation Charges- Sch 3C: Schedule Items Electrical (As per DSR E&M 2025) 0.00 0.00 0.00
पावर ग्रिड कारपोरेशन ऑफ इंडिया लिमिटेड
POWER GRID CORPORATION OF INDIA LTD.
WRTS-II,RHQ,VADODARA
Name of Package: Construction of New Control Room Building at 400/220kV Dehgam Sub-Station.
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Sole Bidder) : To:
Name : Contract Services
Address : Power Grid Corporation of India Ltd.,
Western Region Transmission syatem -II
Plot No. 54, Near Riya revati resort ,
Sama - savli road, vadodara-390008
Installation Charges- Sch 3D: Non Schedule Items Electrical works for Construction of New Control Room Building at 400/220kV Dehgam Sub-Station.
Sl. No. DESCRIPTION OF ITEMS UNIT Quantity Unit Rate Total Amount (Excl. GST) Total Tax GST @ 18% Total Amount (Incl. GST)
Activity Header / Substation Name
Lighting and Air conditioning panel
1 400/220 kV Dehgam S/s Supply and Installation of AC Lighting Panel Indoor type (ACP-1) as per POWERGRID technical specifications. No. 4 0 0 0
2 400/220 kV Dehgam S/s Supply and Installation of DC Lighting Panel Indoor type as per POWERGRID technical specifications. No. 1 0 0 0
3 400/220 kV Dehgam S/s Supply and installation of Air conditioning DB as per POWERGRID technical specifications. SET 2 0 0 0
6 400/220 kV Dehgam S/s Supply and installation of Telephone Junction boxes/tag blocks to suit requirement of 32 telephone connections LS 1 0 0 0
FIRE DETECTION AND ALARM SYSTEM
8 400/220 kV Dehgam S/s Supply and Installation of Fire Detection and Alarm System for Control Room Building as per POWERGRID technical specifications. SET 1 0 0 0
LIGHT FIXTURES & FANS
9 400/220 kV Dehgam S/s Supply and installation of Lighting Fixture: Surface Mounted circular LED downlighter Luminaire in 220V DC (Wattage≤ 8W, IP rating IP-20, surface mounted , input supply voltage 220V DC, Power supply SMPS, THD < 10%, system effcacy ≥80 Lumen/watt system total output ≥640 lm, Housing: Pressure Die Cast , CRI: >80, CCT: 5700k±300k, Operating Humidity: 90%RH, Burning Hours:50000, Operating Temperature: -5ºC to 45ºC, Lumen Maintenance:70% at the end of Burning Hours) Forus FEPL008SDCW or equivalaent. EA 7 0 0 0
10 400/220 kV Dehgam S/s Supply and installation of Lighting Fixture: Recess Mounted circular LED downlighter Luminaire in 220V DC (wattage≤ 8W, IP rating IP-20, Recess mounted , input supply volatege 220V DC, Power supply SMPS, THD < 10%, system effcacy ≥80 Lumen/watt system total output ≥640 lm, Housing: Pressure Die Cast , CRI: >80, CCT: 5700k±300k, Operating Humidity: 90%RH, Burning Hours:50000, Operating Temperature: -5ºC to 45ºC, Lumen Maintenance:70% at the end of Burning Hours) Forus FEPL008RDCW or equivalaent. EA 23 0 0 0
11 400/220 kV Dehgam S/s Supply and installation of Lighting Fixture:Surface Mounted 2x20W Linear LED Tube with Box ( wattage≤ 2x20W, IP rating IP-20, surface mounted , input supply volatege 230V AC, THD < 10%, system effcacy ≥100 Lumen/watt, syatem total output ≥3600 lm,housing material- CRCA, power factor > 0.95,surge protection 2kV, THD < 10%, CRI: >80, CCT: 5700k±300k, Operating Humidity: 90%RH, Burning Hours:50000, Operating Temperature: -5ºC to 45ºC, Lumen Maintenance:70% at the end of Burning Hours) Forus FE2XTR20ACW or equivalaent. EA 33 0 0 0
12 400/220 kV Dehgam S/s Supply and installation of Lighting Fixture:Recessed Mounted 40W LED 4x1 Recessed light ( wattage≤ 40W, IP rating IP-20, Recessed mounted , input supply volatege 230V AC, THD < 10%, system effcacy ≥100 Lumen/watt, system total output ≥3600 lm,housing material- CRCA, power factor > 0.95,Surge protection 2 kV, THD < 10%, CRI: >80, CCT: 5700k±300k, Operating Humidity: 90%RH, Burning Hours:50000, Operating Temperature: -5ºC to 45ºC, Lumen Maintenance:70% at the end of Burning Hours) Forus FE4x1R40ACW or equivalent. EA 24 0 0 0
13 400/220 kV Dehgam S/s Supply and installation of Exhaust fan, 300mm sweep, 1350 RPM , Air delivery CMM ≥1160, crompton drift air or equivalent . EA 13 0 0 0
14 400/220 kV Dehgam S/s Supply and installation of Wall Mounted fan, 400mm sweep, 1300 RPM , Air delivery CMM ≥60, crompton Hi flo 400 mm or equivalent. EA 23 0 0 0
400/220 kV Dehgam S/s Supply and installation of Type D1 Post Top Lantern Pole Of 4 Meter As Per POWERGRID Technical specification (Detailed drawing with specification attached as annexture-1) EA 8 0 0 0
15 400/220 kV Dehgam S/s Supply and installation of Pole Mounted Led Post Top Luminaire Type Sl-D1 ( wattage ≤ 30W, luman output ≥2600, Lumen/watt ≥90, Housing: Di cast aluminum, IP65, 3kV internal surge protection, 10kV external surge protection, mounting: Suitable for 60mm max O.D, THD: <10%, CRI: >70, CCT: 5700k±300k, Power Factor: >0.95, Ik Protection: IK-05, Operating Humidity: 90%RH, Burning Hours:50000, Operating Temperature: -5ºC to 45ºC, Lumen Maintenance:70% at the end of Burning Hours) EA 8 0 0 0
16 400/220 kV Dehgam S/s Supply and fixing following rating 415V, 15kA, "C" curve Four Pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required
17 400/220 kV Dehgam S/s 63A MCB EA 2 0 0 0
18 400/220 kV Dehgam S/s 40A MCB EA 2 0 0 0
19 400/220 kV Dehgam S/s Desing and submission of drawings for Electrical works (illumination system, Airconditioning system, and Fire detection alarm system). LS 1 0.00 0.00 0.00
Total Installation charges of Non Schedule Items 0.00 0.00 0.00
(SUMMARY OF TAXES & DUTIES)
Name Contract Services
Address …….. …… ………. ………. Power Grid Corporation of India Ltd.,
…….. …… ………. ………. Western Region Transmission syatem -II
…….. …… ………. ………. Plot No. 54, Near Riya revati resort ,
Sama - savli road, vadodara-390008
Sl. No. Item Nos. Total Price (in ₹)
1 TOTAL GST on Services
a. Total GST on Supply & Installation Services (indentified in Schedule-3A1) which are not included in the Installationas per the provision of the Bidding Documents, as applicable 4752766.47
b. Total GST on Supply & Installation Services (indentified in Schedule-3B1) which are not included in the Installationas per the provision of the Bidding Documents, as applicable 0.00
c Total GST on Supply & Installation Services (indentified in Schedule-3C) which are not included in the Installationas per the provision of the Bidding Documents, as applicable 0.00
d Total GST on Supply & Installation Services (indentified in Schedule-3D) which are not included in the Installationas per the provision of the Bidding Documents, as applicable 0.00
2 GRAND TOTAL [a+b+c+d] 4752766.47
Date : Printed Name :
Place : Designation :
Grand Summary for Construction of New Control Room Building, at 400/220kV Dehgam Sub-Station.
Name Contract Services
Address …….. …… ………. ………. Power Grid Corporation of India Ltd.,
…….. …… ………. ………. Western Region Transmission syatem -II
…….. …… ………. ………. Plot No. 54, Near Riya revati resort ,
Sama - savli road, vadodara-390008
Sl. No. Description Total Price (INR)
Service/Installation Charges
A TOTAL SCHEDULE NO.-3A
1 Supply & Installation Charges- Schedule Civil Items for Construction of New Control Room Building at Dehgam S/s 2640,42,58.17
B TOTAL SCHEDULE NO.-3B
1 Installation Charges- Non-Schedule Civil Items for Construction of New Control Room Building at Dehgam S/s ,,0.00
C TOTAL SCHEDULE NO.-3C
1 Supply & Installation Charges- Schedule Electrical Items for Construction of New Control Room Building at Dehgam S/s ,,0.00
D TOTAL SCHEDULE NO.-3D
1 Supply & Installation Charges- Non Schedule Electrical Items forConstruction of New Control Room Building at Dehgam S/s ,,0.00
Total of Service/Installation Charge (ITEMS TAB: Item 01 for BID PRICE SUMMARY Statement ) 2640,42,58.17
Total GST against Service/Installation Charge (ITEMS TAB: Item 02 for BID PRICE SUMMARY Statement ) 475,27,66.47
Grand Total ₹ 31,157,024.64
Date : Printed Name :
Place : Designation :
POWER GRID CORPORATION OF INDIA LTD.
WRTS-II,RHQ,VADODARA
BILL OF QUNATITIES FOR Proposed New Control Room Building AS PER DRAWING
SL.No. D.S.R 2023 Item No DESCRIPTION OF ITEM UNIT No. Length Breadth/Width Height Quantity
PART -A SCHEDULE ITEMS - (DSR 2023)
1 1.1 Carriage of materials by mechanical transport including loading, unloading and stacking
1.1.2 EARTH upto 1.00 km. Cum Total excavation 1172.62
Deduct filling -1085.25
2 2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as d
2.6.1 All kind of soil cu.m
Total cu.m 1107.14
3 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
2.8.1 All kinds of soil.
Inclined beam PB1 (D-G) CuM 2 0.75 7.625 0.15 1.72
Inclined beam PB1 (D-G) CuM 1 0.75 2.66 0.15 0.30
Inclined beam PB1 (D-F)-Vertical Grid CuM 1 0.75 6.735 0.15 0.76
PB1 (Grid F-H)-Vertical CuM 1 0.75 2.485 0.15 0.28
PB1 (Grid A-B)-Vertical CuM 2 0.75 5.085 0.15 1.14
PB1 (Grid B-C)-Inclined CuM 2 0.75 1 0.15 0.23
PB2 (Grid B-C)-Inclined -stair CuM 2 0.75 5.87 0.15 1.32
PB2 (Grid D-E)-Vertical, Grid 1-2 CuM 3 0.75 3.97 0.15 1.34
PB2 (Grid D-E)-Vertical, Grid 2-3 CuM 2 0.75 5.88 0.15 1.32
PB2 (Grid D-E)-Vertical, Grid 3-4 CuM 2 0.75 5.2 0.15 1.17
PB3 (Grid B-D), Vertical Grid 4-8 CuM 4 0.75 10.77 0.15 4.85
PB3 (Grid B-D), Vertical Grid 3-4 CuM 2 0.75 5.2 0.15 1.17
PB3 (Grid B-D), Inclined Grid 3-4-Stair CuM 1 0.75 5.49 0.15 0.62
Excavatrion for Plinth Protection Drain CuM 1 81.162 1.21 0.3425 33.64
4 2.10 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc and disposing of the suplus excavated soil as directed, within a lead of 50m:
2.10.1 All kinds of soil.
2.10.1.2 Pipes, cables etc exceeding 80 mm dia but not exceeding 300mm dia mtrs 1 100 100.00
5 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides, of the foundation etc. in layers not exceeding 20 cms in depth, consolidating each deposited layer by ramming and watering, lead upto 50 mtrs and lift upto 1.5 mtrs. Cu.m.
Total Excavation Cu.m. 1172.62
Deduct PCC Cu.m. -91.00
Deduct RCC in footing Cu.m. -103.50
Deduct RCC in column upto plinth Cu.m. -56.13
Filling in plinth
Outside projection front side 1 2.10 7.6 0.3 4.79
Stair landing side 1 5.49 6.5 0.3 10.71
6 2.26 Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked materials.
2.26.1 All kinds of Soil Cu.m.
7 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. Cu.m.
100 mm th. Sand under floor
Outside projection front side 1 2.10 7.6 0.1 1.60
Stair landing side 1 5.49 6.5 0.1 3.57
8 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering : All works upto plinth level.
A 4.1.8 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) Cu.m.
Plinth Beam CuM
Inclined beam PB1 (D-G) CuM 2 0.45 7.625 0.075 0.51
Inclined beam PB1 (D-G) CuM 1 0.45 2.66 0.075 0.09
Inclined beam PB1 (D-F)-Vertical Grid CuM 1 0.45 6.735 0.075 0.23
PB1 (Grid F-H)-Vertical CuM 1 0.45 2.485 0.075 0.08
PB1 (Grid A-B)-Vertical CuM 2 0.45 5.085 0.075 0.34
PB1 (Grid B-C)-Inclined CuM 2 0.45 1 0.075 0.07
PB2 (Grid B-C)-Inclined -stair CuM 2 0.45 5.87 0.075 0.40
PB2 (Grid D-E)-Vertical, Grid 1-2 CuM 3 0.45 3.97 0.075 0.40
PB2 (Grid D-E)-Vertical, Grid 2-3 CuM 2 0.45 5.88 0.075 0.40
PB2 (Grid D-E)-Vertical, Grid 3-4 CuM 2 0.45 5.2 0.075 0.35
PB3 (Grid B-D), Vertical Grid 4-8 CuM 4 0.45 10.77 0.075 1.45
PB3 (Grid B-D), Vertical Grid 3-4 CuM 2 0.45 5.2 0.075 0.35
PB3 (Grid B-D), Inclined Grid 3-4-Stair CuM 1 0.45 5.49 0.075 0.19
100 th. PCC (1:4:8) Soling CuM
Outside projection front side CuM 1 2.1 7.6 0.1 1.60
Stair landing side CuM 1 5.49 6.5 0.1 3.57
PCC for PP Drain CuM 1 81.162 0.91 0.075 5.54
Total 91.00 #REF!
9 4.2 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor,etc., up to floor five level, excluding the cost of centering,shuttering and finishing :
4.2.3 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) Cum
Parapet wall top 5.00
10 4.3 Centering and shuttering including strutting, propping etc. and removalof form work for :
4.3.1 Foundations, footings, bases for columns Sqm
Plinth Beam PCC Work( Considered same as First floor beam)
PB1 (Grid D-F) Sqm 3 0.15 5.2 2.34
Inclined beam PB1 (D-G) Sqm 2 0.15 7.625 2.2875
Inclined beam PB1 (D-G) Sqm 1 0.15 2.66 0.399
Inclined beam PB1 (D-F)-Vertical Grid Sqm 1 0.15 6.735 1.01025
PB1 (Grid F-H)-Vertical Sqm 1 0.15 2.485 0.37275
PB1 (Grid A-B)-Vertical Sqm 2 0.15 5.085 1.5255
PB1 (Grid B-C)-Inclined Sqm 2 0.15 1 0.3
PB2 (Grid B-C)-Inclined -stair Sqm 2 0.15 5.87 1.761
PB2 (Grid D-E) Sqm 2 0.15 5.2 1.56
PB2 (Grid D-E)-Vertical, Grid 1-2 Sqm 3 0.15 3.97 1.7865
PB2 (Grid D-E)-Vertical, Grid 2-3 Sqm 2 0.15 5.88 1.764
PB2 (Grid D-E)-Vertical, Grid 3-4 Sqm 2 0.15 5.2 1.56
PB3 (Grid B-C) Sqm 2 0.15 5.88 1.764
PB3 (Grid C-D) Sqm 2 0.15 5.2 1.56
PB3 (Grid B-D), Vertical Grid 4-8 Sqm 4 0.15 10.77 6.462
PB3 (Grid B-D), Vertical Grid 3-4 Sqm 2 0.15 5.2 1.56
PB3 (Grid B-D), Inclined Grid 3-4-Stair Sqm 1 0.15 5.49 0.8235
PB3 (Grid D-H), Sqm 1 0.15 2 0.3
PCC for PP Drain CuM 1 162.324 0.075 12.1743
11 4.10 Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). sqm
DPC above plinth
PB1 (Grid D-F) Sqm 3 0.23 5.2 3.59
Inclined beam PB1 (D-G) Sqm 2 0.23 7.625 3.51
Inclined beam PB1 (D-G) Sqm 1 0.23 2.66 0.61
Inclined beam PB1 (D-F)-Vertical Grid Sqm 1 0.23 6.735 1.55
PB1 (Grid F-H) Sqm 3 0.23 5.27 3.64
PB1 (Grid F-H)-Vertical Sqm 1 0.23 2.485 0.57
PB1 (Grid A-B) Sqm 3 0.23 3.95 2.73
PB1 (Grid A-B)-Vertical Sqm 2 0.23 5.085 2.34
PB1 (Grid B-C)-Inclined Sqm 2 0.23 1 0.46
PB2 Beam Sqm 0.00
PB2 (Grid B-C) Sqm 1 0.23 3.285 0.76
PB2 (Grid B-C)-Inclined -stair Sqm 2 0.23 5.87 2.70
PB2 (Grid C-D) Sqm 1 0.23 4.715 1.08
PB2 (Grid D-E) Sqm 2 0.23 5.2 2.39
PB2 (Grid D-E)-Vertical, Grid 1-2 Sqm 3 0.23 3.97 2.74
PB2 (Grid D-E)-Vertical, Grid 2-3 Sqm 2 0.23 5.88 2.70
PB2 (Grid D-E)-Vertical, Grid 3-4 Sqm 2 0.23 5.2 2.39
PB3 (Grid B-C) Sqm 2 0.23 5.88 2.70
PB3 (Grid C-D) Sqm 2 0.23 5.2 2.39
PB3 (Grid B-D), Vertical Grid 4-8 Sqm 4 0.23 10.77 9.91
PB3 (Grid B-D), Vertical Grid 3-4 Sqm 2 0.23 5.2 2.39
PB3 (Grid B-D), Inclined Grid 3-4-Stair Sqm 1 0.23 5.49 1.26
PB3 (Grid D-H), Sqm 1 0.23 2 0.46
12 4.12 Extra for providing and mixing water proofing material in cement concrete per 50 kg work in doses by weight of cement as per manufacturer's specification. per 50 kg cement 65.12 0.04 6.4 16.67
13 4.13 Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. sqm 65.12
14 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. sqm 1 95 0.75 71.25
15 5.9 Centring and shuttering including strutting propping etc. and removal of form for :
A 5.9.1 Foundations, footings, bases of columns etc. for mass concrete. Sq.m.
B 5.9.2 Walls (any thickness) including attached pilasters, buttresses, plinth & string courses etc. U.G.W.T. Sq.m. 10.00
C 5.9.3 Suspended floors, roofs, landings, balconies and access platform Sq.m.
Stair landing SqM 1 5.49 1.5 8.24
Mumty roof slab SqM 1 8.015 6.019 48.24
FF Roof Slab 0.00
Outside projection front side SqM 1 2.1 7.6 15.96
Stair landing SqM 1 5.49 1.5 8.24
D) 5.9.5 Lintels, beams, plinth beams, girders, bressumers & cantilevers Sq.m.
Plinth Beam RCC Work( Considered same as First floor beam) SqM
Inclined beam PB1 (D-G) SqM 2 1.2 7.6250 18.3000
Inclined beam PB1 (D-G) SqM 1 1.2 2.6600 3.1920
Inclined beam PB1 (D-F)-Vertical Grid SqM 1 1.2 6.7350 8.0820
PB1 (Grid F-H)-Vertical SqM 1 1.2 2.4850 2.9820
PB1 (Grid A-B)-Vertical SqM 2 1.2 5.0850 12.2040
PB1 (Grid B-C)-Inclined SqM 2 1.2 1.0000 2.4000
PB2 Beam SqM 0.0000
PB2 (Grid B-C)-Inclined -stair SqM 2 1.2 5.8700 14.0880
PB2 (Grid D-E)-Vertical, Grid 1-2 SqM 3 1.2 3.9700 14.2920
PB2 (Grid D-E)-Vertical, Grid 2-3 SqM 2 1.2 5.8800 14.1120
PB2 (Grid D-E)-Vertical, Grid 3-4 SqM 2 1.2 5.2000 12.4800
PB3 (Grid B-D), Vertical Grid 4-8 SqM 4 1.5 10.7700 64.6200
PB3 (Grid B-D), Vertical Grid 3-4 SqM 2 1.5 5.2000 15.6000
PB3 (Grid B-D), Inclined Grid 3-4-Stair SqM 1 1.5 5.4900 8.2350
First Floor Beam (5.9.5) 0.0000 0.0000
FB1 Beam 0.0000
Inclined beam FB1 (D-G) SqM 2 1.5 7.6250 22.8750
Inclined beam FB1 (D-G) SqM 1 1.5 2.6600 3.9900
Inclined beam FB1 (D-F)-Vertical SqM 1 1.5 6.7350 10.1025
FB1 (Grid F-H)-Vertical SqM 1 1.5 2.4850 3.7275
FB1 (Grid A-B)-Vertical SqM 2 1.5 5.0850 15.2550
FB1 (Grid B-C)-Inclined SqM 2 1.5 1.0000 3.0000
FB2 Beam 0.0000
FB2 (Grid B-C)-Inclined -stair SqM 2 1.5 5.8700 17.6100
FB2 (Grid D-E)-Vertical, Grid 1-2 SqM 3 1.5 3.9700 17.8650
FB2 (Grid D-E)-Vertical, Grid 2-3 SqM 2 1.5 5.8800 17.6400
FB2 (Grid D-E)-Vertical, Grid 3-4 SqM 2 1.5 5.2000 15.6000
FB3 (Grid B-D), Vertical Grid 4-8 SqM 4 1.8 10.7700 77.5440
FB3 (Grid B-D), Vertical Grid 3-4 SqM 2 1.8 5.2000 18.7200
FB3 (Grid B-D), Inclined Grid 3-4-Stair SqM 1 1.8 5.4900 9.8820
Roof beam (Considered same as First floor beam) (5.9.5) 0.0000
RB1 Beam 0.0000
Inclined beam RB1 (D-F)-Vertical SqM 1 1.5 6.7350 10.1025
RB1 (Grid F-H)-Vertical Grid SqM 1 1.5 2.4850 3.7275
RB1 (Grid B-C)-Inclined SqM 2 1.5 1.0000 3.0000
RB2 Beam 0.0000
RB2 (Grid B-C)-Inclined -stair SqM 2 1.5 5.8700 17.6100
RB2 (Grid D-E)-Vertical, Grid 1-2 SqM 3 1.5 3.97 17.8650
RB2 (Grid D-E)-Vertical, Grid 2-3 SqM 2 1.5 5.88 17.6400
RB2 (Grid D-E)-Vertical, Grid 3-4 SqM 2 1.5 5.20 15.6000
RB3 (Grid B-D), Vertical Grid 4-8 SqM 4 1.8 10.77 77.5440
RB3 (Grid B-D), Vertical Grid 3-4 SqM 2 1.8 5.20 18.7200
RB3 (Grid B-D), Inclined Grid 3-4-Stair SqM 1 1.8 5.49 9.8820
Lintel Beam SqM 1 50 0.73 36.5000
E 5.9.6 Columns, pillars, piers abutments posts & struts
Column upto FGL (5.9.6) SqM
Column Above FGL 0
F) 5.9.7 Stairs (excluding landings) except spiral staircases.
Waist Slab Bottom & Sides (Main Stair) 4 2.7 2.3 24.84
Waist Slab Bottom & Sides (Main Stair) 2 1.5 2.3 6.90
Waist Slab Bottom & Sides (Rear Side Stair) 2 3.5 1.8 12.60
G) 5.9.13 Vertical and horizontal fins individually or forming box louvers,bands,facias,and eaves boards. Sqm 20.00
H 5.9.14 Extra for shuttering in circular work (20% of respective centering and shuttering items) SqM
Circular Column shuttering
C7 (Circular)-F1 SqM 5.50
I 5.9.15 Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like Sq.m.
Lintel beams over internal doors Sq.m. 20.00
J 5.9.16 Edges of slabs and breaks in floors and walls Metre
5.9.16.1 Under 20 cm wide Metre
Edge of Slab for GF and FF Metre 2 100 200
Mumty Slab Metre 1 27.468 27.468
K 5.9.19 Weather shade, chajjas, corbels etc. including edges. Sq.m. 30.00
16 5.11 Extra for additional height in centring &, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels over a height of 3.5 m for every additional height of 1m or part thereof (Plan area to be measured)
5.11.1 Suspended floors, roofs, landings, beams and balconies (Plan area to be measured) Sq.m. 1 8.015 5.72 45.84
17 5.22 Steel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in postion and binding all complete up to plinth level.
5.22.6 Thermo-Mechanically Treated bars Kg.
Comlumn upto plinth lvl 34 169.8445 5774.713
Plinth beam 250 18.3012 4575.3
Total for Steel upto plinth lvl KG 18358.133
18 5.22A Steel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in postion and binding all complete above plinth level. 3259.0665135
5.22A.6 Thermo-Mechanically Treated bars Kg. As per standard
Beam( GF Slab+ FF Slab) 600 18.3012 10980.72
Columns above plinth level upto Floor V 34 277.2325 9425.905 15
19 5.30 Add for plaster drip corse/groove in plastered surface or moulding to RCC projections. Mtr. 3220.83
20 5.33 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge.
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
5.33.1.1 All works upto plinth level
Trapezoidal portion CuM 2 0.03 5.59 0.37
sub-total (A) 103.50
Column upto FGL Cu.m
C7 (Circular)-F1 CuM 2 3.14 0.15 2.875 2.71
Sub-total (B) 17.57
Inclined grid beam PB1 (D-G) CuM 2 0.30 0.6 7.625 2.75
Inclined grid beam PB1 (D-G) CuM 1 0.30 0.6 2.66 0.48
Inclined beam PB1 (D-F)-Vertical Grid CuM 1 0.30 0.6 6.735 1.21
PB1 (Grid F-H)-Vertical grid CuM 1 0.30 0.6 2.485 0.45
PB1 (Grid A-B)-Vertical grid CuM 2 0.30 0.6 5.085 1.83
PB1 (Grid B-C)-Inclined grid CuM 2 0.30 0.6 1 0.36
PB2 (Grid B-C)-Inclined -stair CuM 2 0.30 0.6 5.87 2.11
PB2 (Grid D-E)-Vertical, Grid 1-2 CuM 3 0.30 0.6 3.97 2.14
PB2 (Grid D-E)-Vertical, Grid 2-3 CuM 2 0.30 0.6 5.88 2.12
PB2 (Grid D-E)-Vertical, Grid 3-4 CuM 2 0.30 0.6 5.2 1.87
PB3 (Grid B-D), Vertical Grid 4-8 CuM 4 0.30 0.75 10.77 9.69
PB3 (Grid B-D), Vertical Grid 3-4 CuM 2 0.30 0.75 5.2 2.34
PB3 (Grid B-D), Inclined Grid 3-4-Stair CuM 1 0.30 0.75 5.49 1.24
Sub-Total (D) 56.13 0.15 compact earth
Total 177.20 0.15 PCC
Say 177.20 0.5 Pedestal
b 5.33.2.1 All works above plinth level upto floor V level #REF! Depth
C7 (Circular)-F1 CuM 2 3.14 0.15 4.375 4.12
Outside Paragola
Stair landing CuM 1 5.49 1.5 0.125 1.03
Mumty roof slab CuM 1 8.02 6.019 0.125 6.03
First floor slab
Outside projection front side CuM 1 2.10 7.6 0.125 2.00
Stair landing CuM 1 5.49 1.5 0.125 1.03
First Floor Beam
Inclined beam FB1 (D-G) CuM 2 0.30 0.6 7.625 2.75
Inclined beam FB1 (D-G) CuM 1 0.30 0.6 2.66 0.48
Inclined beam FB1 (D-F)-Vertical CuM 1 0.30 0.6 6.735 1.21
FB1 (Grid F-H)-Vertical CuM 1 0.30 0.6 2.485 0.45
FB1 (Grid A-B)-Vertical CuM 2 0.30 0.6 5.085 1.83
FB1 (Grid B-C)-Inclined CuM 2 0.30 0.6 1 0.36
FB2 (Grid B-C)-Inclined -stair CuM 2 0.30 0.6 5.87 2.11
FB2 (Grid D-E)-Vertical, Grid 1-2 CuM 3 0.30 0.6 3.97 2.14
FB2 (Grid D-E)-Vertical, Grid 2-3 CuM 2 0.30 0.6 5.88 2.12
FB2 (Grid D-E)-Vertical, Grid 3-4 CuM 2 0.30 0.6 5.2 1.87
FB3 (Grid B-D), Vertical Grid 4-8 CuM 4 0.30 0.75 10.77 9.69
FB3 (Grid B-D), Vertical Grid 3-4 CuM 2 0.30 0.75 5.2 2.34
FB3 (Grid B-D), Inclined Grid 3-4-Stair CuM 1 0.30 0.75 5.49 1.24
Roof beam (Considered same as First floor beam)
Inclined beam RB1 (D-F)-Vertical CuM 1 0.30 0.6 6.735 1.21
RB1 (Grid F-H)-Vertical Grid CuM 1 0.30 0.6 2.485 0.45
RB1 (Grid B-C)-Inclined CuM 2 0.30 0.6 1 0.36
RB2 (Grid B-C)-Inclined -stair CuM 2 0.30 0.6 5.87 2.11
RB2 (Grid D-E)-Vertical, Grid 1-2 CuM 3 0.30 0.6 3.97 2.14
RB2 (Grid D-E)-Vertical, Grid 2-3 CuM 2 0.30 0.6 5.88 2.12
RB2 (Grid D-E)-Vertical, Grid 3-4 CuM 2 0.30 0.6 5.2 1.87
RB3 (Grid B-D), Vertical Grid 4-8 CuM 4 0.30 0.75 10.77 9.69
RB3 (Grid B-D), Vertical Grid 3-4 CuM 2 0.30 0.75 5.2 2.34
RB3 (Grid B-D), Inclined Grid 3-4-Stair CuM 1 0.30 0.75 5.49 1.24
21 5.35 Add for using extra cement in the items of design mix over and above the specified cement content therein. quintal
Upto plinth level quintal 177.20 @.33 qtl/cu.m. 58.48
Above plinth level quintal 282.96 @.33 qtl/cu.m. 93.38
22 6.1 Brick work with common burnt clay F .P .S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work in Plinth protection drain 1 95 0.23 0.30 6.555
23 6.4 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in 1 2.1
6.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cu.m 0.9 2.1
Ground floor -230 mm th. Brickwork above 1 161.799 0.23 3.40 126.53
First floor -230 mm th. Brickwork above 1 165.595 0.23 3.40 129.50
Mumty parapet 1 27.508 0.23 0.90 5.69
Deduction for door
Deduction for Window
24 6.13 Half brick masonry with common burnt clay F .P .S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)
115 th. Brickwall -Ground floor SqM 1 21.565 3.4 73.321 21.565
115 th. Brickwall -first floor SqM 1 59.24 3.4 201.416
External Shaft wall 50 0.6 8.5 255
25 6.15 Extra for providing and placing in position 2 Nos., 6mm dia M.S. bars at every third course of half brick masonry. Sq.m. Qty same as half brick work 523.46
26 NS-21 Supplying, filling and compacting stone boulders mixed with sand under foundations, roads, cable trenches, drains etc in layers not exceeding 250mm thickness including ramming, watering, compacting etc.(DSR Item No.16.3,16.4,16.3.8)
27 8.2 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
A) 8.2.1 Rajnagar plain White marble/Udaipur green marble/Zebra black marble
(i) 8.2.1.1 Area of slab upto 0.50 sqm Sq.m. 10.00
(ii) 8.2.1.2 Area of slab over 0.50 sqm Sq.m.
B) 8.2.2 Granite of any colour and shade
(i) 8.2.2.1 Area of slab upto 0.50 sqm Sq.m.
Partition of Urinal 3 0.45 0.9 1.215
Steps of Main Entrance, Riser 3 2.5 0.15 1.125
Stair Riser 28 2 0.15 8.4
(ii) 8.2.2.2 Area of slab over 0.50 sqm Kitchen platform Sq.m.
Wash Basin Counter SqM 7 0.6 1 4.2
Box Planter Top SqM 1 6 0.3 1.8
Box Planter front SqM 1 6 0.3 1.8
Pantry Platform SqM 1 3 0.6 1.8
Entrance SqM 1 2 3 6
Stair Tread SqM 27 2 0.3 16.2
Steps of Main Entrance, Tread SqM 2 2.5 0.3 1.5
Window & ventilator
28 8.4 Extra for fixing marble /granite stone, over and above corresponding basic,item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. Metre 1 20 20.00
29 8.5 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. Each 7 7.00
30 8.31 Providing and Fixing 1st quality ceramic glazed wall tiles conforming to IS 15622(thickness to bespecified by the manufacturer) of approved make in all colours, shades except burgundy, bottle-green, black of any size as approved by the Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of Cement mortar 1:3 (1 Cement:3 Coarse Sand) and jointing with grey cement slurry @ 3.3 kg per sq m including pointing in white cement mixed with pigment of matching shade complete. Sq.m.
Toilets & Pantry SqM
Toilet at GF SqM 1 8.35 2.1 17.535
Disable Toilet SqM 1 8 2.1 16.8
Common toilet at first floor SqM
Ladies Toilet SqM 1 9.07 2.1 19.047
Wash basin artea of Gents toilet SqM 1 12 2.1 25.2
Station incharge toilet SqM 1 5.97 2.1 12.537
Conference room toilet SqM 1 5.97 2.1 12.537
Pantry SqM 1 4.1 1.2 4.92
31 9.71 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : Each
9.71.1 125x64x2.50 mm Each
Hinges for door shutter
31 9.87 Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete : Each
33 9.88 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Each 12.00 12.00
34 9.92 Providing and fixing chromium plated brass handles with necessary screws etc. complete:
35 9.75 Providing and fixing bright finished brass door latch with necessary screws etc. complete :.
36 9.74 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :
37 9.101 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour & shade with necessary screws etc. complete
9.101.2 Twin rubber stopper Each 1.00 25.00 25.00
38 9.117 Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin-charge
9.117.2 Extruded section profile size 42x50 mm metre
D1 metre 2 5.8 11.6
D6 metre 2 5.1 10.2
D7 metre 1 5.7 5.7
39 9.136 Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately). Metre
40 9.137 Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately). Sqm
41 9.138 Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 60 minutes of fire resistance both integrity & radiation control (EW60) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm. Sqm 7 0.25 0.25 0.4375
42 9.139 Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. Each 7 7
43 9.147 Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3 (ii) Sites with structure height more than 20m for all wind speeds Sqm
Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.
A 9.147A1 Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.
9.147.A1.2 Using R3 series with frame (55 mm & above) x (40 mm & above) & sash (30 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every panel along with multi-point locking system (Height upto 1.8m
B 9.147A2 Two track four panels sliding windows with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on three panels along with multi-point locking system, nylon rollers with SS 304 body
9.147.A2.1 Using R3 series with frame (55 mm & above) x (40 mm & above) & sash (30 mm & above) x (55 mm & above) (Height upto 1.8m).
C 9.147B1 Two track two panels sliding door with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on every panel along with multi-point locking system, adjustable nylon rollers with SS 304 body.
9.147B1.1 Using R3 series with frame (55 mm & above) x (40 mm & above) & sash (30 mm & above) x (74 mm & above). (Height upto 2.5 metre).
D 9.147C1 Fixed window / ventilator without mullion / transom.
9.147.C1.4 Using R4 series with frame (64 mm & above) x (50 mm & above). (Height above 2.5 metre) Sqm
E 9.147F1 Casement door single panel with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides.
9.147F1.1 Using R3 series with frame (55 mm & above) x (50 mm & above) & sash (55 mm & above) x (85 mm & above) (Height upto 2.5 metre).
44 10.2 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Kg
Indoor cable trench Sec 2A-2A (30 m)
MS Earthing flate along the Trench 60 0.075 0.006 7850 211.95
ISMC 100 for chequered plate support @ 750 mmC/C @9.2 kg/m as per SP: 6(1)-19*64 reaffirmed 2003 40 1.35 54 9.2 496.8
Cleat angle 50*50*5 for ISMC Support 80 0.1 8 3.8 30.4
6 mm thk. Chequered plate 1 15 1.35 0.006 953.775
Total 2581.6718
45 10.18 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. Each 1 50 50.00
46 10.25 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. Kgs
10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works Kgs
Balcony railing (49.5x49.5x3.6 @4.93 kg/m)
Horizontal tube Balcony railing 1 1 50 246.50
Vertical tube 1 60 0.9 266.22
Horizontal tube (25x25x3.2) @ 1.98 kg/m 1 5 50 495.00
47 10.27 Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. Each
48 10.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
For Entrance ramp
Top rail, 40 NB (SS), Medium duty @ 3.56 kg/m as per IS 1161 Kgs. 2 6 3.56 42.72
Mid Rail 20NB (SS), Medium duty @ 1.56 kg/m Kgs. 2 6 1.56 18.72
Vertical post 25 NB (SS), Medium duty @2.41 kg/m Kgs. 18 0.9 2.41 39.042
For main Stair Kgs.
50 NB dia SS hand rail, in wall and railing, Medium duty @ 5.03 kg/m Kgs. 1 15 5.03 75.45
40 NB Bluster Kgs. 26 0.75 3.56 69.42
20 NB Bluster Kgs. 26 0.15 3.56 13.884
20 NB Horizontal pipes fixed in bluster Kgs. 2 15 1.56 46.8
For Fire escape stair Kgs.
50 NB dia SS hand rail, in wall and railing, Medium duty @ 5.03 kg/m Kgs. 2 8 5.03 80.48
40 NB Bluster Kgs. 15 0.75 3.56 40.05
20 NB Bluster Kgs. 15 0.15 3.56 8.01
20 NB Horizontal pipes fixed in bluster Kgs. 2 8 1.56 24.96
Total 585.29 #REF!
49 11.5 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. Sqm
ACDB Room Sqm 1 15.77 10.77 169.84
Deduct for cable trench area Sqm -1 30 1.6 -48.00
DCDB room Sqm 1 10.27 5.27 54.12
Deduct for cable trench area Sqm -1 10.27 1.6 -16.43
Ramp of ACDB & DCDB & Battery Room 3 3 2.5 22.50
50 11.6 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. Sqm
11.6.1 18 mm thick Sqm
ACDB Room Sqm 1 53.08 0.15 7.96
Deduct forDoor Area Sqm -1 1.5 0.15 -0.23
Deduct for door D9 -1 2.5 0.15 -0.38
DCDB room Sqm 1 31.08 0.15 4.66
Deduct forDoor Area Sqm -1 1.2 0.15 -0.18
Deduct for door D9 -1 2.5 0.15 -0.38
51 11.23.5 Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :
11.23.5 Udaipur green marble sqm 10.00
52 11.24 Extra for pre finished nosing to treads of steps of marble stone. metre 10.00
53 11.25 Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre . Main entry sqm 10.00
54 11.39 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete. Sqm
Toilets & Pantry SqM
Toilet at GF SqM 1 2.85 2.5 7.125
Disable Toilet SqM 1 2.85 1.6 4.56
Common toilet at first floor SqM
Ladies Toilet SqM 1 2.5 1.635 4.0875
Wash basin artea of Gents toilet SqM 1 3.835 4 15.34
Station incharge toilet SqM 1 1.5 1.885 2.8275
Conference room toilet SqM 1 1.5 1.885 2.8275
55 11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make in all colours and shades,laid on 20 mm thick cement mortar 1:4(1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete.
(A) 11.41.2 Size of tile 600 X 600 mm Sq.m.
non- executive Room SqM 1 7.385 5.27 38.91895
battery room SqM 1 10.27 5.27 54.1229
Record room SqM 1 3.81 2.985 11.37285
Mumty area SqM 1 5.94 8.875 52.7175
control room SqM 1 6.02 5.27 31.7254
station incharge SqM 1 6.135 5.97 36.62595
conference SqM 1 8.77 5.27 46.2179
executive SqM 1 10.77 6.02 64.8354
Pantry SqM 1 2.95 3 8.85
56 11.46 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.
11.46.2 Size of Tile 600x600 mm Sq.m.
non- executive Room SqM 1 25.31 0.15 3.80
battery room SqM 1 31.08 0.15 4.66
Record room SqM 1 13.59 0.15 2.04
Mumty area SqM 1 29.63 0.15 4.44
First Floor 0 0.15 0.00
elec. Lab SqM 1 21.31 0.15 3.20
control room SqM 1 22.58 0.15 3.39
station incharge SqM 1 24.21 0.15 3.63
conference SqM 1 28.08 0.15 4.21
executive SqM 1 33.58 0.15 5.04
Pantry SqM 1 11.9 0.15 1.79
57 11.48 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling /grouting and finishing complete as per direction of Engineer-in-charge.
11.48.2 Size of Tile 600x600 mm sqm Qty same as that of flooring 525.14
58 11.50 Deduct for not grouting the joints with white cement and matching pigmenin the items of fixing of vitrified tiles. Sqm Qty same as that of flooring 525.14
59 11.56 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Sq.m.
A) 11.56.1 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent Sq.m.
B) 11.56.2 Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red Sq.m. LS 10.00
60 12.21 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : metre
12.21.1 In 75x75 mm deep chase
Terrace 1 85 85
Mumty Slab 1 27.45 27.45
Porch area 1 44 44
61 12.22 Making khurras 45 x 45 cm with average minimum thickness of 5cm cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1mx1mx400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete. Each 17 17.00
62 12.41 Providing and fixing on wall face unplasticised -Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.
( i ) Single socketed pipes
12.41.2 110 mm diameter metre 15 8.45 126.75
metre 2 2.75 5.5
63 12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
A) 12.42.1 Coupler
B) 12.42.3 Single Tee with door
D) 12.42.6 Shoe (Plain)
64 12.43 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised -PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
65 12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams. Each 17 17.00
66 12.52 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
12.52.3 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. Sqm
Control Room 1 6.02 5.27 31.73
Conference Room 1 8.77 5.27 46.22
Incharge Room 1 6.135 5.97 36.63
Executive Room 1 10.77 5.27 56.76
Non Executive room 1 7.385 5.27 38.92
Electric Lab room 1 5.385 5.27 28.38
Battery Room 1 10.27 5.27 54.12
67 12.55 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner Sqm 1 11 11 121.00
68 18.58 Providing and fixing PTMT grating of approved quality and colour.
Rectangular type with openable circular lid 18.58.2.1 150 mm nominal size square 100 mm diameter of the inner hinged round grating Each 17 17.00
69 13.4 12 mm cement plaster of mix :
13.4.2 1:6 (1 cement : 6 coarse sand). Sq.m.
Battery room 1 31.08 3.85 119.658 Beam Bottom
Record Room 1 9.995 3.85 38.48075
Non Executive Room 1 21.655 3.85 83.37175
Stair Cabin 1 18.94 3.85 72.919
Executive Room 1 33.58 3.85 129.283
Conference Room 1 19.06 3.85 73.381
Electrical Lab 1 21.31 3.85 82.0435
Control Room 1 17.31 3.85 66.6435
Incharge Room 1 18.075 3.85 69.58875
Toilet internal Partition wall 1 7 3.85 26.95
Deduction for door
Deduction for Window
70 13.5 15 mm cement plaster on rough side of single or half brick masonry wall of mix :
13.5.2 1:6 ( 1 cement : 6 coarse sand) Sqm.
Lobby Area 1 23.64 3.85 91.014
Battery Room 1 5.27 3.85 20.2895
Record room 1 2.985 3.85 11.49225
Disable toilet 1 2.85 3.85 10.9725
Conference Room 1 8.77 3.85 33.7645
Control Room 1 5.27 3.85 20.2895
Incharge Room 1 5.97 3.85 22.9845
71 13.9 Cement plaster 1:3 ( 1cement : 3 coarse sand) finished with a floating coat of neat cement :
13.9.1 12 mm cement plaster Sqm.
Plinth protection drain inner plaster 2 105 0.78 163.8
72 13.11 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 Cement : 5 Coarse sand) finished with top layer 6 mm thick cement plaster 1:6 (1 Cement : 6 Fine sand) Sq.m.
external Plaster (18mm) in brickwork above
Brickwall -Ground floor 1 90.44 4.5 406.980
Brickwall -first floor 1 81.94 4 327.760
Parapet on Terrace 1 97.5 2.03 197.925
Parapet on Mumty 1 24.438 2.03 49.609
External Shaft wall 50 1.3 8.5 552.5
13.16.1 6 mm cement plaster of mix :
1:3 (1 cement : 3 fine sand)
Stair landing Sqm 1 5.49 1.5 8.235
Mumty roof slab Sqm 1 8.015 6.019 48.242285
First floor slab Sqm
Outside projection front side Sqm 1 2.1 7.6 15.96
Stair landing Sqm 1 5.49 1.5 8.235
First Floor Beam Sqm
FB1 (Grid D-F) Sqm 3 5.2 1.2 18.72
Inclined beam FB1 (D-G) Sqm 2 7.625 1.2 18.3
Inclined beam FB1 (D-G) Sqm 1 2.66 1.2 3.192
Inclined beam FB1 (D-F)-Vertical Sqm 1 6.735 1.2 8.082
FB1 (Grid F-H) Sqm 3 5.27 1.2 18.972
FB1 (Grid F-H)-Vertical Sqm 1 2.485 1.2 2.982
FB1 (Grid A-B) Sqm 3 3.95 1.2 14.22
FB1 (Grid A-B)-Vertical Sqm 2 5.085 1.2 12.204
FB1 (Grid B-C)-Inclined Sqm 2 1 1.2 2.4
FB2 (Grid B-C) Sqm 1 3.285 1.2 3.942
FB2 (Grid B-C)-Inclined -stair Sqm 2 5.87 1.2 14.088
FB2 (Grid C-D) Sqm 1 4.715 1.2 5.658
FB2 (Grid D-E) Sqm 2 5.2 1.2 12.48
FB2 (Grid D-E)-Vertical, Grid 1-2 Sqm 3 3.97 1.2 14.292
FB2 (Grid D-E)-Vertical, Grid 2-3 Sqm 2 5.88 1.2 14.112
FB2 (Grid D-E)-Vertical, Grid 3-4 Sqm 2 5.2 1.2 12.48
FB3 (Grid B-C) Sqm 2 5.88 1.5 17.64
FB3 (Grid C-D) Sqm 2 5.2 1.5 15.6
FB3 (Grid B-D), Vertical Grid 4-8 Sqm 4 10.77 1.5 64.62
FB3 (Grid B-D), Vertical Grid 3-4 Sqm 2 5.2 1.5 15.6
FB3 (Grid B-D), Inclined Grid 3-4-Stair Sqm 1 5.49 1.5 8.235
FB3 (Grid D-H), Sqm 1 2 1.5 3
Roof beam (Considered same as First floor beam) Sqm 0
RB1 (Grid D-F) Sqm 3 5.2 1.2 18.72
Inclined beam RB1 (D-F)-Vertical Sqm 1 6.735 1.2 8.082
RB1 (Grid F-H) Sqm 3 5.27 1.2 18.972
RB1 (Grid F-H)-Vertical Grid Sqm 1 2.485 1.2 2.982
RB1 (Grid A-B) Sqm 3 3.95 1.2 14.22
RB1 (Grid B-C)-Inclined Sqm 2 1 1.2 2.4
RB2 (Grid B-C) Sqm 1 3.285 1.2 3.942
RB2 (Grid B-C)-Inclined -stair Sqm 2 5.87 1.2 14.088
RB2 (Grid C-D) Sqm 1 4.715 1.2 5.658
RB2 (Grid D-E) Sqm 2 5.2 1.2 12.48
RB2 (Grid D-E)-Vertical, Grid 1-2 Sqm 3 3.97 1.2 14.292
RB2 (Grid D-E)-Vertical, Grid 2-3 Sqm 2 5.88 1.2 14.112
RB2 (Grid D-E)-Vertical, Grid 3-4 Sqm 2 5.2 1.2 12.48
RB3 (Grid B-C) Sqm 2 5.88 1.5 17.64
RB3 (Grid C-D) Sqm 2 5.2 1.5 15.6
RB3 (Grid B-D), Vertical Grid 4-8 Sqm 4 10.77 1.5 64.62
RB3 (Grid B-D), Vertical Grid 3-4 Sqm 2 5.2 1.5 15.6
RB3 (Grid B-D), Inclined Grid 3-4-Stair Sqm 1 5.49 1.5 8.235
RB3 (Grid D-H), Sqm 1 2 1.5 3
74 13.21 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers per bag of 50kg cement used in the mix Area same as external plaster 243.77
75 13.22 Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. Sqm 1 27.568 1.25 34.46
13.23 Extra for plastering on circular work not exceeding 6 m in radius:
13.23.1 In one coat
On corcular column 2 0.942 3.4 6.41
76 13.27 Extra for lining out plaster to imitate stone or concrete blocks walling. Sq.m. 1499.22
77 13.24 Extra for plastering done on moulding, cornices or architraves including neat finish to line and level:
A 13.24.1 In one coat Sq.m. LS 30.00
B 13.24.2 In two coats LS 30.00
78 13.26 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. Sq.m. 3284.67
79 13.45 Finishing walls with textured exterior paint of required shade : Sq.m.
13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm Sq.m. LS 150.00
80 13.47 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: Sq.m.
13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) Sq.m. 1499.22
81 13.50 Applying priming coat:
13.50.3 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works Sq.m. 45.00
82 13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete 1499.22
83 13.83 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Sq.m.
13.83.2 Two coats Sqm 3284.67
84 13.85 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. Sq.m.
13.85.3 With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre Sq.m. 3284.67
85 13.62 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture Sq.m.
86 16.68 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Both side of connecting road Sq.m. 30.00
87 16.88 Providing and laying matt finished vitrified tile of size 100x100x16mm having water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in out door floors such as footpath, court yard multi models etc., laid on 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as direction of Engineer-in-Charge. Sq.m.
88 16.91 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.
16.91.1 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
At entrance Sq.m. 20.00
89 17.10 Providing and fixing stainless steel A ISI 304(18/8) kitchen sink as per IS:13983 with CI brackets and stainless steel plug 40 mm, including painting of fittings & brackets cutting and making good the walls wherever required
17.10.1 Kitchen sink with drain board
17.10.1.4 Size 510 x 1040 bowl depth 178 mm Each 1 1
90 17.12 Providing and fixing draining board with C.I. brackets including painting of brackets, cutting and making good the walls wherever required :
17.12.1 White glazed fire clay draining board of size 600x450x 25 mm Each 1 1
91 17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Each
17.28.2 Flexible pipe Each
17.28.2.1 32 mm dia Each 1 1
92 17.30 Providing and fixing in position 25 mm diameter mosquito proof coupling of approved muncipal design Each Each 8 8
93 17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P . brass screws and washers complete. each 817.95 Each 8 8
94 17.78 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover , and cistern fittings, nuts, bolts and gasket etc complete. Each 6 6
95 17.80 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. Each 3 3
96 17.34 Providing and fixing toilet paper holder :
(A) 17.34.1 C.P. brass Each 6 6
97 17.69 Providing and fixing PTMT Waste Coupling for wash basin and sink,of approved quality and colour.
17.69.2 Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms Each 6 6
98 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
a 18.7.2 20 mm nominal dia Pipes meter 1 50 50
b 18.7.4 32 mm nominal dia Pipes meter 1 50 50
c 18.7.5 40 mm nominal dia Pipes meter 1 100 100
99 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
A 18.8.1 15 mm nominal outer dia Pipes meter 1 50 50
B 18.8.2 20 mm nominal outer dia Pipes meter 1 50 50
100 18.12 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work
A 18.12.6 50 mm dia nominal bore meter 1 20 20
B 18.12.7 65 mm dia nominal bore meter 1 50 50
C 18.12.8 80 mm dia nominal bore meter 1 100 100
101 18.13 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
18.13.2 50 to 80 mm nominal bore each 5 5
102 18.14 Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). each 5 5
103 18.17 Providing and fixing gun metal gate valve with CI wheel of approved quality (screwed end)
A 18.17.1 25 mm nominal bore each 2 2
B 18.17.2 32 mm nominal bore. each 2 2
C) 18.17.4 50 mm nominal bore 2 2
D) 18.17.5 65 mm nominal bore 2 2
E) 18.17.6 80 mm nominal bore 2 2
104 18.18 Providing and fixing ball valve (brass) of approved quality High or low pressure with plastic floats complete.
18.18.3 25 mm nominal bore Each 2 2
105 18.19 Providing and fixing gun metal non-return valve of approved quality (screwed end)
18.19.1 25 mm nominal bore Each
A) 18.19.1.1 Horizontal Each 1 1
18.19.1.3 Vertical Each 1 1
18.19.3 40 mm nominal bore
A) 18.19.3.1 Horizontal Each 1 1
18.19.3.2 Vertical Each 1 1
B 18.19.4 50 mm nominal bore
18.19.4.1 Horizontal Each 1 1
18.19.4.2 Vertical Each 1 1
C) 18.19.5 65 mm nominal bore
18.19.5.1 Horizontal Each 1 1
18.19.5.2 Vertical Each 1 1
D) 18.19.6 80 mm nominal bore
18.19.6.1 Horizontal Each 1 1
18.19.6.2 Vertical Each 1 1
106 18.21 Providing and fixing uplasticised PVC connection pipe with brass unions :
(A) 18.21.2 45 cm length
18.21.2.1 15 mm nominal bore Each 2 2
107 18.22 Providing and fixing CP brass shower rose with 15 or 20 mm inlet.
(A) 18.22.1 100 mm diameter Each 1 1
108 18.32 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :
(A) 18.32.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Each 10 10
109 18.34 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
18.34.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 each 3 3
110 18.40 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :
A 18.40.6 50 mm diameter pipe meter 1 20 20
C 18.40.7 65 mm diameter pipe meter 1 50 50
C 18.40.8 80 mm diameter pipe meter 1 100 100
111 18.41 Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work :
18.41.6 50 mm diameter pipe meter 1 20 20
18.41.7 65 mm diameter pipe meter 1 50 50
18.41.8 80 mm diameter pipe meter 1 100 100
112 18.48 Providing and placing on terrace(at all floor levels) polyethylene water storage tank ISI: 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base suport for tank: per litre 1 2000 2000
113 18.49 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : Each
18.49.1 15 mm nominal bore Each 1
114 18.51 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. Each
18.51.1 15 mm nominal bore Each 1
115 18.52 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. Each
18.52.1 15 mm nominal bore Each 5
116 18.53 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 Each
18.53.1 15mm nominal bore Each 14
117 18.58 Providing and fixing PTMT grating of approved quality and colour
18.58.2 Rectangular tupe with openable circular lid
18.58.2.1 150 mm nominal size square 100mm diametre of the inner hinged round grating Each 12 12
118 18.84 Providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. Each 4 4
119 19.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)all around SW pipes including bed concrete as per standard design.
A 19.2.1 100 mm diameter S W Pipe Meter 50 50
B 19.2.2 150 mm diameter S W Pipe Meter 20 20
120 19.4 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
(A) 19.4.3 180x150 mm size P type
19.4.3.2 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Each 4 4
121 19.6 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
A 19.6.2 150 mm dia. R.C.C. pipe metre 1 10 10
B 19.6.4 300 mm dia. R.C.C. pipe metre 1 10 10
C 19.6.5 450 mm dia. R.C.C. pipe metre 1 10 10
122 19.7 Constructing brick masonry manhole in bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of a neat cement complete as per standard design.
19.7.1 Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total wt. of cover and frame to be not less than 38 kg. (wt. of the cover 23 kg and wt. of the frame 15 kg.)
19.7.1.2 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Each 10 10
123 19.8 Extra for depth for manholes
(A) 19.8.1 Size 90 x 80 cm
19.8.1.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Meter 5 5
124 19.16 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. Each 10 10
125 19.35 Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete
19.35.1 450 mm dia RCC pipes. metre 1 10 10
19.35.2 600 mm dia RCC pipes. metre 1 10 10
126 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
A 21.1.1. fixed portion
(i) 21.1.1.3 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)
SQ.MT As per attached sheet of Aluminium Windows 460.2449 460.24
127 21.3 Providing and fixing glazing in aluminium door, window,ventilator,shutter and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the architectual drawings and the directions of Engineer in charge(Cost of aluminium snap beading shall be paid in basic item)
A 21.3.2 With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
B 21.3.3 With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) sqm 0.45 0
128 21.8 Filling the gap in between aluminium frame and adjacent RCC/Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in Charge complete.
21.8.1 Up to 5mm depth and 5mm width metre
C1 metre 4 21.3 85.2
C2 metre 1 10.3 10.3
C3 metre 1 24.7 24.7
W1 metre 4 7.3 29.2
W1x metre 1 7.3 7.3
W2 metre 20 5.3 106
129 21.15 Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete.
21.15.3 Polyester powder coated minimum thickness 50 micron aluminium Each
C1 Each 4 16 64
C2 Each 1 10 10
C3 Each 1 22 22
W1 Each 4 10 40
W1x Each 1 10 10
W2 Each 20 8 160
130 21.18 Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc. to be paid separately) sqm
Main Door sqm 1 2.7 2.5 6.75
131 22.5 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of:
(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surfaces.
(ii) Iind course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand ) mixed with water proofing compound in recommended prportion including rounding off junction of vertical and horizontal surfaces.
(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg per sq.m. of area.
(iv) Ivth course of 400 micron thick PVC sheet. (overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sq.m.)
Toilet floor Sq.m. 3 4 1.5 2.06 37.08
2nd Toilet Sq.m. 3 4 2.28 1.5 41.04
Add for sides- Toilet Sq.m. 3 4 7.12 0.45 38.448
132 22.7 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies terraces etc. consisting of following operations.
(a) Applying a slurry coat of neat cement using 2.75Kg/sq.m. of cement admixed with water proofing compound conforming to IS:2645 and approved by Engneer in charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.
(b)Laying brick bats with mortar using broken bricks/brick bats 25mm to 1115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineer in charge over 20mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineer in charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of the junctions of walls and slabs.
(c )After two days of proper curing applying a second coat of cement slurry using 2.75 kg/sq.m. of cement admixed with water proofing compound conforming to IS:2645 and approved by the Engineer in charge.
(d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineer in charge and finally finishing the surface with trowel with neat cement slurry and making of 300 x 300mm square 3 mm deep.
(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order & as directed and specified by the Engineer-in-charge.
22.7.1 With average thickness of 120 mm and minimum thickness at Khurra as 65mm Sq.m.
Terrace area- as per plan Sq.m. 1 450 450
133 26.86 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door / window / clerestory windows & desertory other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
A 26.86.1 Frame size 45 x 70 mm Metre
D2, metre 6 5 30.00
D6 metre 2 5.1 10.20
B 26.86.6 Frame size 65 x 125 mm
D1 metre 2 5.8 11.60
D1x, D3 metre 4 5.2 20.80
D7 metre 1 5.7 5.70
134 26.88 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/ mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
A 26.88.1 30 mm thick
PART-(B) : NON DSR ITEMS (NON SCHEDULED ITEM)
SL.No. NS Item DESCRIPTION OF ITEM UNIT No. Length Breadth/Width Height Quantity
1 NS-1 Supply, Diluting & injecting chemical emulsion ecluding of the cost of the chemical emulsion) for PRE-CONSTRUCTIONAL ANTI TERMITE treatment and creating a continuos chemical barrier under all round the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes, conduits etc. complete as per specifications. (Plinth area of the building at ground floor only shall be measured for payment)
(A) Chloropyriphos/Lindane emulsifiable concentrate of 20% Sq.m.
Plinth area Sq.m. 1 450 450
2 NS-2 Providing and fixing rubber shock absorbers of minimum 25 mm dia and 40 mm length to be fixed on back side of door including screws and nuts etc. all complete. Each
3 NS-3 Providing and placing cinder/brick bat filling to the sunk floors in toilets/kitchen sunks, well compacted carefully by hand beating to required slopes including consolidation, curing, (mix shall be one part of cement mortar 4 parts of Cinder/brickbat finishing the same with the cement mortor 1:4 (1cement:4 coarse sand) by adding water proofing compound as per manufacturers recommendations including providing 25mm dia PVC drain pipe of required length. For toilet and Kitchen sunkun portions Cu.m
4 NS-4 Providing, fixing , laying, testing & commissioning (Concealed/surface mounted or underground) uPVC SWR Rigid pipes confirming to IS 13592-1992 of PRICE/SUPREME/FINOLEX or equivalent make of working pressure 6kg/sq.cm for drainage line including necessary fittings such as couplers, bends, tees, cross tees, cowls, clamps, rubber packing ring etc. confirming to DIN 19561, DIN 19534, IS 14735-99, IS-5382, joining with adhessive solvent cement including cost of jointing materials and all other necessary fixtures, fitting, air and water tight testing of the line etc. complete at all levels. (Centre line length of completed pipe line shall be measured for payment purpose)
NS-4A A 40mm outer dia. Metre 1 30 30
NS-4B B 75mm outer dia.
In toilets Metre 1 30 30
In kitchen Metre 1 10 10
External line upto manhole for toilets Metre 1 45 45
External line upto manhole for kitchens Metre 1 15 15
NS-4C C 110mm outer dia.
In toilets Metre 1 45 45
External line Metre 1 50 50
5 NS-5 Providing, fixing, testing and commissioning uPVC SWR Nahani trap, plain floor trap/ Multi floor trap with strainer/top cover etc. confirming to DIN 19531, DIN 19534, IS 14735-99, IS-5382 of 110 mm dia inlet and 75 mm outlet nominal dia. including fixing PVC reducer of 110mm dia. to 75 mm dia. and jointing with adhessive solvent cement including cost of cutting and making good the walls and floors at all levels etc. complete.
Toilets Each 14 14
Kitchen Each 2 2
7 NS-7 Providing & fixing Hindware/Jaquar make or equivalent bathroom accessories including cutting wall/making holes and making good the surface with the same finish as directed by the Engineer in charge.
NS 7A A CP brass high flow single lever concealed diverter with body and plate for bath and shower system.
Batch cum WC Each 1 1
NS 7B B CP brass hand shower (Health faucet) for WC/EWC system
Batch cum WC Each 6 6
NS 7C C CP Concealed flush valve 32 mm of make Jaquar FLV-CHR-1095 or equivalent make as approved complete. Each 6 6
8 NS 8 NS-8 Forming groove of uniform size in the external plaster surface as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge :
20 mm wide and 6 mm deep groove metre 750
9 NS 9 NS-9 Providing and fixing C.P. brass towel ring of make kohler cat no- 17528T-CP or Jaquar Continental: ACN-CHR-1121N or equivalent make fixed with PVC cleats and brass screws including cutting and making good the walls wherever required complete as directed by Engineer-in-charge. Each
10 NS 10 NS-10 Providing and Fixing Towel rack with single rail of make Jaquar -Cat No: AHS-CHR-1581 or ,kohler cat no- 17529T-CP or equivalent as approved with Rawl Plugs and brass screws complete as directed by Engineer-in-charge. Each
11 NS 11 NS-11 Providing and fixing liquid soap dispenser horizontal /vertical matt finish with simple push lever of make Jaquar ACN-CHR-1137N or Kohler cat K -10712D-CP or equivalent as approved including cutting and making good the walls, wherever required complete as directed by Engineer-in-charge. Each
12 NS 12 NS-12 Providing and Fixing C.P. brass Central Hole basin mixer without pop up waste system of make Jaquar Model: CON-CHR-167KNB or kohler cat no- 16027IN-4ND-CP or equivalent make as approved with 450mm long copper pipe and brass nuts including cutting and making good the walls wherever required complete as directed by Engineer-in-charge. Each
13 NS 13 NS-13 Providing and Fixing Over head Rose shower with revolving joint (with body rotation), 115 mm long shower arm of make Jaquar Cat No: OHS-CHR-1989 or kohler cat no- 16356IN-A-CP or equivalent make as approved complete as directed by Engineer-in-charge Each 1
14 NS 14 NS-14 Providing and Fixing Soap dish of make Jaquar Continental ACN-CHR-1131 N or kohler cat no- 17524T-CP or equivalent make as approved with PVC / Wooden plugs and screws including making good the walls wherever required complete as directed by Engineer-in-charge. Each 6
15 NS 15 NS-15 Providing and fixing 6mm thick Clear mirror with bevelled edge on the wall over 6mm thick polycorbonate sheet with ss screw / stud, machine cut in required size, approved shade & colour etc. complete with all respect at all levels as directed by Engineer-in-charge. (Sample of Mirror shall be got approved from Engineer-in-Charge). Each
16 NS 16 NS-16 Providing and Fixing 32mm CP Brass bottle trap complete with 250 mm long wall connecting pipe of Jaquar ALD-CHR-769 B or kohler cat no- 16407IN-CP or equivalent make as approved of size including CP Wall flange complete as directed by Engineer-in-charge. Each
17 NS 17 NS-17 Providing and fixing white color vitreous China oval shape, under counter wash basin of make of Kohler cat. no. 2211 IN-O or jaquar FLS-WHT-0401 or equivalent as approved of 32mm dia outlet with CP Brass connection, Rubber adopter for waste connection and CI Brackets etc including cutting and making good the walls wherever required complete as per direction of engineer-in-charge. Each 7
18 NS 18 NS-18 Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in aluminium doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). SqM 10
20 NS-20 NS-20: Supply and filling of good quality moorum under floor in layers not exceeding 20 cms in depth, consolidating each deposited layer by ramming and watering, consolidating and dressing complete. (Measurement shall be based on compacted volum CU.M 450 0.1 45
22 NS 25 NS-25 Providing and fixing Door handles satin finish 25mm x 600mm long Dorma/ozon/Crif make including the cost of all material, labour, transportation, taxes, incidentals etc. as per the directions and instructions of Engineer-in-Charge Each 16
23 NS 26 NS-26 Door lock satin finish Dorma/ozon/Crif make including the cost of all material, labour, transportation, taxes, incidentals etc. as per the directions and instructions of Engineer-in-Charge Each 16
24 NS 27 NS-27 Providning and fixing curtain rods of min 1.25 mm thick SS plate, with two SS brackets and matching finials and hardware fixed on to wooden plugs etc, wherever necessary complete including the cost of all material, labout, machinery, transportation etc. as per the directions and instructions of engineer-in-Charge Mtr 100
25 NS 28 NS-28 Providing and fixing louvered windows consists of 2" x 1" box type heavy duty(16 Guage min.) "JINDAL / INDAL / HINDALCO" make aluminium anodised (according to IS: 1868, Minimum anodic coating of grade AC 15) window frame with fixed aluminium louver system of same guage to have a standard aluminium louver section (blade) including the cost of all necessary fixtures and fittings, transportation, labour etc. complete in all respect as per the instructions of Engineer-in-Charge Kg 20
Part:D Non-Scheduled Items Electrical
Unit Qty Unit Price 10% erection charges total xharges with 15% contractor profit Total
1 Supply and installation of Lighting Fixture: Surface Mounted circular LED downlighter Luminaire in 220V DC (Wattage≤ 8W, IP rating IP-20, surface mounted , input supply volatege 220V DC, Power supply SMPS, THD < 10%, system effcacy ≥80 Lumen/watt syatem total output ≥640 lm,housing material- pressure die casting, ≥80, Housing: Pressure Die Cast , CRI: >80, CCT: 5700k±300k, Operating Humidity: 90%RH, Burning Hours:50000, Operating Temperature: -5ºC to 45ºC, Lumen Maintenance:70% at the end of Burning Hours) Forus FEPL008SDCW or equivalaent. Each 1.00 ₹ 649.50 ₹ 64.95 ₹ 821.62 ₹ 821.62 E market rates referred from Havells light 9W
2 Supply and installation of Lighting Fixture: Recess Mounted circular LED downlighter Luminaire in 220V DC (wattage≤ 8W, IP rating IP-20, Recess mounted , input supply volatege 220V DC, Power supply SMPS, THD < 10%, system effcacy ≥80 Lumen/watt syatem total output ≥640 lm,housing material- pressure die casting, ≥80, Housing: Pressure Die Cast , CRI: >80, CCT: 5700k±300k, Operating Humidity: 90%RH, Burning Hours:50000, Operating Temperature: -5ºC to 45ºC, Lumen Maintenance:70% at the end of Burning Hours) Forus FEPL008RDCW or equivalaent. Each 1.00 ₹ 649.50 ₹ 64.95 ₹ 821.62 ₹ 821.62 E market rates referred from Havells light 9W
3 Supply and installation of Lighting Fixture:Surface Mounted 2x20W Linear LED Tube with Box ( wattage≤ 2x20W, IP rating IP-20, surface mounted , input supply volatege 230V AC, THD < 10%, system effcacy ≥100 Lumen/watt, syatem total output ≥3600 lm,housing material- CRCA, power factor > 0.95, THD < 10%, CRI: >80, CCT: 5700k±300k, Operating Humidity: 90%RH, Burning Hours:50000, Operating Temperature: -5ºC to 45ºC, Lumen Maintenance:70% at the end of Burning Hours) Forus FE2XTR20ACW or equivalaent. Each 1.00 ₹ 2,272.00 ₹ 227.20 ₹ 2,874.08 ₹ 2,874.08 E market rates referred from forus light 40W
4 Supply and installation of Lighting Fixture:Recessed Mounted 40W LED 4x1 Recessed light ( wattage≤ 40W, IP rating IP-20, Recessed mounted , input supply volatege 230V AC, THD < 10%, system effcacy ≥100 Lumen/watt, syatem total output ≥3600 lm,housing material- CRCA, power factor > 0.95, THD < 10%, CRI: >80, CCT: 5700k±300k, Operating Humidity: 90%RH, Burning Hours:50000, Operating Temperature: -5ºC to 45ºC, Lumen Maintenance:70% at the end of Burning Hours) Forus FE4x1R40ACW or equivalent. Each 1.00 ₹ 2,272.00 ₹ 227.20 ₹ 2,874.08 ₹ 2,874.08 E market rates referred from forus light 40W
5 Supply and installation of Exhaust fan, 300mm sweep, 1350 RPM , Air delivery CMM ≥1160, crompton drift air or equivalent . Each 1 2489 248.9 3148.585 3148.585 E amrket rate crompton exhaust fan drift air
6 Supply and installation of Wall Mounted fan, 400mm sweep, 1300 RPM , Air delivery CMM ≥60, crompton Hi flo 400 mm or equivalent. Each 1 3699 369.9 4679.235 4679.235 E amrket rate crompton wall fan hiflo
Measurement of works for Construction of New Control Room Building at 400/220kV Dehgam Sub-Station.
Battery Room 6 Recess
Non Executive Room 6 Total Consealed lighting wiring point 110
Total Recess lighting wiring point 137
Total Staircase lighting wiring point 8
Total power point wiring 65
Record Room 2 Recess Total 320
DCDB 9 Consealed
Passage 23 Recess
Non Executive Room 2 Recess
ACDB 5 Consealed
ACDB 6 Consealed
ACDB 4 Consealed
Non Executive Room 4 Consealed
ACDB 4 Consealed
6 Module Non Executive Room 6
Non Executive Room 2
CONTROL ROOM 8 Recess
ELECTRONIC TEST ROOM 4
CONFERENCE ROOM 10
EXECUTIVE ROOM 10
SS IC ROOM 2 Consealed
CONFERENCE ROOM 2
Passage 30 Recess
ELECTRONIC TEST LAB 4
AT OPEN TERRACE 8 Consealed
ELECTRONIC TEST LAB 1 Recess
EXECUTIVE ROOM 2
CONFERENCE ROOM 2
PANTRY 1 Consealed
SS IC ROOM TOILET 1 Consealed
ELECTRONIC TEST LAB 2 Consealed
EXECUTIVE ROOM 4
CONFERENCE ROOM 5
ELECTRONIC TEST LAB 5 Consealed
6 Module PASSAGE 4
EXECUTIVE ROOM 8
CONFERENCE ROOM 10
ELECTRONIC TEST LAB 1
EXECUTIVE ROOM 4
CONFERENCE ROOM 3
POWER GRID CORPORATION OF INDIA LTD.
WRTS-II,RHQ,VADODARA
BILL OF QUNATITIES FOR Type- C AS PER STANDARD TOWNSHIP DRAWING
SL.No. D.S.R 2021 Item No DESCRIPTION OF ITEM UNIT No. Length Breadth/Width Height B2 (Qty for 01 block)
PART -A SCHEDULE ITEMS - (DSR 2021)
1 1.1 Carriage of materials by mechanical transport including loading, unloading and stacking 5 14 70
1.1.2 EARTH upto 1.00 km. Cum Total excavation
3A 2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as d
2.6.1 All kind of soil cu.m
3B 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
2.8.1 All kinds of soil.
3C Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre). cu.m 32 2.5 2.50 1.00 200.00
4 2.10 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc and disposing of the suplus excavated soil as directed, within a lead of 50m:
2.10.1 All kinds of soil.
2.10.1.2 Pipes, cables etc exceeding 80 mm dia but not exceeding 300mm dia mtrs 2 50 1 50.00
5 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides, of the foundation etc. in layers not exceeding 20 cms in depth, consolidating each deposited layer by ramming and watering, lead upto 50 mtrs and lift upto 1.5 mtrs. Cu.m.
Total Excavation Cu.m. 798.21
Deduct PCC Cu.m. -36.63
Deduct RCC in footing Cu.m. -110.59
Deduct RCC in column upto plinth Cu.m. -12.59
Volume of moorum filling below foundations Cu.m. 0.00
6.1 2.26 Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked materials.
2.26.1 All kinds of Soil Cu.m.
6.2 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. Cu.m.
FILLING ABOVE GROUND As per block b1 Area 276 0.3 82.80
8 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering : All works upto plinth level.
A 4.1.8 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) Cu.m.
9 4.2 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor,etc., up to floor five level, excluding the cost of centering,shuttering and finishing :
4.2.3 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) Cum
Parapet wall top 1 88 0.23 0.115 2.33
10 4.3 Centering and shuttering including strutting, propping etc. and removalof form work for :
4.3.1 Foundations, footings, bases for columns Sqm
11 4.10 Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). sqm
At plinth level 1 90 0.23 20.70
12 4.12 Extra for providing and mixing water proofing material in cement concrete per 50 kg work in doses by weight of cement as per manufacturer's specification. per 50 kg cement 1 20.70 0.04 6.4 5.30
13 4.13 Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. sqm 1 100 0.23 23.00
14 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. sqm 1 90 0.75 67.50
15 5.9 Centring and shuttering including strutting propping etc. and removal of form for :
A 5.9.1 Foundations, footings, bases of columns etc. for mass concrete. Sq.m.
Footing pedestal 32 2 2 4 0.6 307.20
B 5.9.2 Walls (any thickness) including attached pilasters, buttresses, plinth & string courses etc. U.G.W.T. Sq.m. 4 3 2.6 31.20
C 5.9.3 Suspended floors, roofs, landings, balconies and access platform Sq.m.
FF slab + Roof Slab
each unit area 4 117.93 471.72
Stair foyer Sq.m. 4 1 3.1 2.93 36.33
Landing Sq.m. 4 1 2.93 1.40 16.41
Stair cabin Sq.m. 1 1 3.1 7.32 22.69
D) 5.9.5 Lintels, beams, plinth beams, girders, bressumers & cantilevers Sq.m.
First Floor slab
Second Floor slab
Roof slab level beam Sq.m. 1 7.32 0.93 6.81
E 5.9.6 Columns, pillars, piers abutments posts & struts
RCC Columns upto plinth level Sq.m. 32 2.5 1.66 132.80
Plinth to gf slab Column Sq.m. 32 3.15 1.66 167.33
first floor to second floor Sq.m. 32 3.15 1.66 167.33
second floor to terrace Sq.m. 32 3.15 1.66 167.33
stair cabin Sq.m. 4 3.15 1.66 20.92
F) 5.9.7 Stairs (excluding landings) except spiral staircases.
Staircase Waiste slab- HP TO First Floor Sq.m. 2 3.155 1.50 9.47
First floor to second floor Sq.m. 2 3.15 1.50 9.45
second floor to terrace Sq.m. 2 3.15 1.50 9.45
G) 5.9.13 Vertical and horizontal fins individually or forming box louvers,bands,facias,and eaves boards. Sqm
Drawing room balcony pardi Sqm 1 6.08 1.43 8.69
H 5.9.15 Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like Sq.m.
Lintel beams over internal doors Sq.m. 42 1 1 0.415 17.43
I 5.9.19 Weather shade, chajjas, corbels etc. including edges. Sq.m.
Window Chajja Sq.m. 12 2 0.60 14.40
edge of chajja 12 2 0.1 2.40
Weathershade chajjas Sq.m. 8 1 1.3 0.60 6.24
Edge of chajja in RFT 8 1 1.3 10.40
16 5.11 Extra for additional height in centring &, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels over a height of 3.5 m for every additional height of 1m or part thereof (Plan area to be measured)
5.11.1 Suspended floors, roofs, landings, beams and balconies (Plan area to be measured) Sq.m. 1 2.4 4.90 11.76
17 NS21 Steel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in postion and binding all complete up to plinth level.
NS21 Thermo-Mechanically Treated bars Kg.
Comlumn upto plinth lvl 210 12.59 2642.976
Plinth beam 145 38.18 5536.416825
UGWT Bottom and top slab 65 0
Total for Steel upto plinth lvl KG 29608.557825
18 NS22 Steel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in postion and binding all complete above plinth level.
NS22 Thermo-Mechanically Treated bars Kg. As per standard
Columns above plinth level upto Floor V
Columns above plinth level upto Floor V 210 40.35 8473.7205
19 5.30 Add for plaster drip corse/groove in plastered surface or moulding to RCC projections. Mtr.
Window chajja 1 1 5.26 5.26
Weathershade chajjas 4 1 3.205 12.82
At mumty level 1 1 3 3.00
20 5.33 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge.
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
5.33.1 All works upto plinth level
sub-total (A) 110.59
PLINTH BEAM Cu.m 3 27.37 0.23 0.45 8.50
Sub-total (B) 38.18
as per unit carpet area 276.00
Stair foyer Cu.m 2 1 3.1 2.93 0.10 1.82
Sub-total (C) 278.64
RCC Columns upto plinth level
Sub-Total (D) 12.59 0.15 compact earth
Total 440.00 0.15 PCC
Say 440.00 0.5 Pedestal
b 5.33.2 All works above plinth level upto floor V level 2.1 Depth
GF slab level beam 0.75 Plinth
FF slab level beam Cu.m 3 25.4 0.23 0.45 7.89
SF slab level beam Cu.m 3 25.4 0.23 0.45 7.89
Roof slab level beam Cu.m 2 7.32 0.23 0.45 1.52
Sub-Total (A) 116.39
Stair foyer Cu.m 2 1 3.1 2.93 0.12 2.18
Stair foyer Cu.m 2 1 3.1 2.93 0.12 2.18
Staircase Waiste slab cu.m 6 3.155 1.50 0.15 4.26
Stair cabin cu.m 1 3.18 7.32 0.15 3.49
Kitchen platform slab cu.m 4 1 3.6 0.60 0.075 0.65
Kitchen loft cu.m 4 1 3.6 0.45 0.075 0.49
Facia in canopy cu.m 1 1 2.4 0.10 0.30 0.07
Lintel beams over internal doors cu.m 44 1 1.5 0.115 0.15 1.14
Sub-Total (B) 101.33
RCC columns From Plinth level to Second Floor level cu.m 22 0.6 0.3 3.15 3 37.42
RCC in Columns above roof slab upto parapet level cu.m 12 0.23 0.45 1.05 1.30
RCC columns from roof level to mumty parapet level cu.m 4 0.23 0.45 3.925 1.62
Sub-Total © 40.35
Total for chajja 2.16
21 5.35 Add for using extra cement in the items of design mix over and above the specified cement content therein. quintal
Upto plinth level quintal 440.00 @.50 qtl/cu.m. 220.00
Above plinth level quintal 260.23 @.50 qtl/cu.m. 130.12
22 6.1 Brick work with common burnt clay F .P .S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand)
For surface drain Cu.m. 2 70 0.23 0.3 9.66
Below plinth beam Cu.m. 1 80 0.23 1 18.40
23 6.4 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in
6.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cu.m 3 100 0.23 3 207.00
Less winvow 3 30 -90.00
24 6.13 Half brick masonry with common burnt clay F .P .S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)
First Floor 2 x 9 x 2.55 = 45.90
Second Floor 2 x 9 x 2.55 = 45.90
25 6.15 Extra for providing and placing in position 2 Nos., 6mm dia M.S. bars at every third course of half brick masonry. Sq.m. Qty same as half brick work 279.17
26.1 23.5 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge
26.2 23.7 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge
27 8.2 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
A) 8.2.1 Rajnagar plain White marble/Udaipur green marble/Zebra black marble
(i) 8.2.1.1 Area of slab upto 0.50 sqm Sq.m. 1 10 0.5 5.00
(ii) 8.2.1.2 Area of slab over 0.50 sqm Sq.m.
Kitchen Shelf Sq.m. 1 4 2.5 0.45 4.50
B) 8.2.2 Granite of any colour and shade
(i) 8.2.2.1 Area of slab upto 0.50 sqm Sq.m. 8 1.5 0.23 2.76
Windpw sill 12 0.9 0.23 2.48
(ii) 8.2.2.2 Area of slab over 0.50 sqm Kitchen platform Sq.m. 4 1 3.6 0.75 10.80
28 8.4 Extra for fixing marble /granite stone, over and above corresponding basic,item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. Metre 4 1 3.6 14.40
29 8.5 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. Each 8 1 1 8.00
32 9.134.1.2.1 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws ::
9.134.1.2.1 30 mm thick shutters
Main door sqm 4 1 1.05 2.1 8.82
33 9.46 Providning and fixing curtain rods of 1.25 mm thick chromium plated brass plate,with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs etc, wherever necessary complete:
9.46.3 25 mm dia. metre
For Windows 4 8 1.5 48.00
34 9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
9.48.2 Fixed to openings/wooden frames with rawl plugs & screws etc.
Balcony railing 49.5x49.5x3.6 mm living room Kgs. 4 6.08 18 kg per meter 437.76 25mm pipe 2.41 kg per meter 3 7.23
bed Kgs. 4 7.8 18 kg per meter 561.60 verticalsupport
bed Kgs. 4 8.6 18 kg per meter 619.20 40mm pipe 3.56 kg per meter 1 3.36
@ 15kg/sq.m. of window area Kg 113.78 @15 kg/m. 1706.67
35 9.119 Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer-in-Charge. metre
Toilets D3 metre 4 3 4.95 59.40
36 9.124 Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75 mm x 30 mm having wall thickness 5 mm. The styles, top & bottom rails shall have one side wall thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with M.S. tubes of size 33 mm x 17 mmx 1 mm, painted with primer , all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and the rails with a cavity, to receive single piece extruded 5 mm PVC sheet as panel. The styles and rails will be mitred cut and joint with the help of PVC solvent cement & self driven self tapping screws. Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100 mm x 8 mm complete as per manufacturer's specifications and direction of Engineer-in-charge.
9.124.2 Decorative finish (both side wood grained finish) sqm
Toilets D3 sqm 4 1 2.1 0.75 6.30
37 9.20 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face ven
9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
D1 (mumty door) Sq.m 1 1 0.90 2.10 1.89
9.22 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) SqM 4 3 0.90 2.10 22.68
9.22.1 On one side only 1 1 0.90 2.10 1.89
38 10.18 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. Each 4 7 1 28.00
39 10.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Staircase railing 40 mm NB Kgs. 4 9.4 37.6 18 kg per meter 676.80 40mm pipe 3.56 kg per meter 1 3.56
Balcony railing 49.5x49.5x3.6 mm living room Kgs. 4 6.08 18 kg per meter 0.00 25mm pipe 2.41 kg per meter 3 7.23
bed Kgs. 4 7.8 18 kg per meter 0.00 verticalsupport
bed Kgs. 4 8.6 18 kg per meter 0.00 40mm pipe 3.56 kg per meter 1 3.36
40 11.23.5 Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :
11.23.5 Udaipur green marble sqm
In landings 1 6 2.4 1.2 17.28
Entrance 1 1 2.4 1.43 3.43
41 11.24 Extra for pre finished nosing to treads of steps of marble stone. metre 1 54.00 1.5 81.00
42 11.25 Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre . Main entry sqm 5 3 0.45 6.75
43 8.31 Providing and Fixing 1st quality ceramic glazed wall tiles conforming to IS 15622(thickness to bespecified by the manufacturer) of approved make in all colours, shades except burgundy, bottle-green, black of any size as approved by the Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of Cement mortar 1:3 (1 Cement:3 Coarse Sand) and jointing with grey cement slurry @ 3.3 kg per sq m including pointing in white cement mixed with pigment of matching shade complete. Sq.m.
In dado of toilet Sq.m. 4 1 6.45 2.1 54.18
In dado above kitchen platform toilet Sq.m. 4 1 4.8 2.1 40.32
44 11.39 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete. Sqm
In toilet Sq.m. 4 2.1 1.5 12.60
45 11.41 Providing and laying vitrified floor tiles in different sizes(thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make in all colours and shades,laid on 20 mm thick cement mortar 1:4(1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete.
(A) 11.41.2 Size of tile 600 X 600 mm Sq.m.
46 11.48 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling /grouting and finishing complete as per direction of Engineer-in-charge.
11.48.2 Size of Tile 600x600 mm sqm Qty same as that of flooring 420.00
47 11.50 Deduct for not grouting the joints with white cement and matching pigmenin the items of fixing of vitrified tiles. Sqm Qty same as that of flooring 420.00
48 12.22 Making khurras 45 x 45 cm with average minimum thickness of 5cm cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1mx1mx400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete. Each 1 8 8.00
49 12.41 Providing and fixing on wall face unplasticised -Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.
( i ) Single socketed pipes
12.41.2 110 mm diameter metre 8 10 80.00
50 12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
A) 12.42.1 Coupler
B) 12.42.3 Single Tee with door
D) 12.42.6 Shoe (Plain)
51 12.43 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised -PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
52 12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams. Each 1 8 8.00
53 18.58 Providing and fixing PTMT grating of approved quality and colour.
Rectangular type with openable circular lid 18.58.2.1 150 mm nominal size square 100 mm diameter of the inner hinged round grating Each 1 8 8.00
54 13.4 12 mm cement plaster of mix : slab 6 MM
13.4.2 1:6 (1 cement : 6 coarse sand). Sq.m.
Each unit 4 117.93 471.72
Stair cabin slab 1 3.15 6.5 20.475
Stair bottom 6 3.15 1.5 28.35
Stair side 6 3.15 0.3 5.67
55 13.5 15 mm cement plaster on rough side of single or half brick masonry wall of mix :
13.5.2 1:6 ( 1 cement : 6 coarse sand) Sqm.
Hollow plinth Column 32 1.8 3.15 181.44
stair wall 2 6.32 3.15 39.82
Bedroom 1 (2 nos)
long wall 2 4.5 3 27
short wall 2 3.6 3 21.6
Bedroom 2 (2 nos)
long wall 2 4.6 3 27.6
short wall 2 3.3 3 19.8
long wall 2 3.6 3 21.6
short wall 2 3 3 18
Drawing room(2 nos)
long wall 2 6.68 3 40.08
opening -1 0.9 3 -2.7
short wall 2 4.91 3 29.46
long wall 2 1.5 3 9
window -1 1 1.5 -1.5
opening -1 0.9 3 -2.7
short wall 2 1.4 3 8.4
Toilet plaster 152.46
Second Floor 336.08
Parapet plaster 1 83 83 1.25 103.75 103.75
56 13.9 Cement plaster 1:3 ( 1cement : 3 coarse sand) finished with a floating coat of neat cement :
13.9.1 12 mm cement plaster Sqm. LS 20.00
57 13.11 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 Cement : 5 Coarse sand) finished with top layer 6 mm thick cement plaster 1:6 (1 Cement : 6 Fine sand) Sq.m.
Outer perimiter 3 98 3.5 1029.00
Less window -3.00 56.68 -170.04
Less balcony gaps -2 6.6 1.5 -19.80
58 13.24 Extra for plastering done on moulding cornices or architraves including neat finish to line and level:
13.24.1 In two coats Sq.m. LS 20.00
59 13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete Sqm Qty same as internal plaster including ceiling except staircase, stilt area 1047.80 INCLUDING STAIR
61 13.47 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) Sq.m. 803.52 FULL
62 13.83 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
13.83.2 Two coats Qty same as internal plaster including ceiling except staircase, stilt area 1047.80
63 13.85 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.
A 13.85.3 With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre Qty same as internal plaster including ceiling except staircase, stilt area 1047.80
64 13.62 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
13.62.1 Two coats Sqm
MS Work wherever required 150.00
65 16.68 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. Sq.m.
Entrance pavement Sq.m. 1 280 1 280.00
66 17.1 Providing and fixing water closet Squatting pan (Indian WC type) with 100 mm sand cast iron P or S trap, 10 litres low level white PVC flushing cistern including flush pipe with manually controlled device (handle lever) confirming to IS 7231 with all fittings and fixtures complete including, cutting and making good the walls and floors wherever required.
17.1.1 White vitreous china Orissa pattern WC pan of size 580 mm x 440 mm with integral type foot rest, Each 4 1 1 4.00
67 17.7B Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock.
(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer Each 8 1 1 8.00
68 17.10 Providing and fixing stainless steel A ISI 304(18/8) kitchen sink as per IS:13983 with CI brackets and stainless steel plug 40 mm, including painting of fittings & brackets cutting and making good the walls wherever required
17.10.1 Kitchen sink with drain board
17.10.1.4 Size 510 x 1040 bowl depth 178 mm Each 4 1 1 4.00
69 17.70.2 Providing and fixing PTMT Bottle Trap for Wash basin and sink Each 4 3 2 24.00
70 17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P . brass screws and washers complete. each 817.95 Each 4 2 1 8.00
71 17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality, colour and make weighing not less than 88 gms Each 4 2 1 8.00
72 17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved qualityand colour
17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm wide and effective height of 88 mm, weighing not less than 190 gms. Each 4 2 1 8.00
73 17.74 Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. Each 4 2 1 8.00
74 17.78 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover , and cistern fittings, nuts, bolts and gasket etc complete. Each 4 1 1 4.00
75 17.34 Providing and fixing toilet paper holder :
(A) 17.34.1 C.P. brass Each 4 1 1 4.00
76 17.69 Providing and fixing PTMT Waste Coupling for wash basin and sink,of approved quality and colour.
17.69.2 Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms Each 4 3 1 12.00
77 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes
a 18.7.2 20 mm nominal outer dia Pipes meter 100.00
b 18.7.4 32 mm nominal dia Pipes meter 50.00
c 18.7.5 40 mm nominal dia Pipes meter 50.00
78 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
A 18.8.1 15 mm nominal outer dia Pipes meter 100.00
B 18.8.2 20 mm nominal outer dia Pipes meter 100.00
79 18.17 Providing and fixing gun metal gate valve with CI wheel of approved quality (screwed end)
A 18.17.1 25 mm nominal bore each 4.00
B 18.17.2 32 mm nominal bore. each 4.00
80 18.18 Providing and fixing ball valve (brass) of approved quality High or low pressure with plastic floats complete.
18.18.3 25 mm nominal bore Each 2 1 1 2.00
81 18.19 Providing and fixing gun metal non-return valve of approved quality (screwed end)
18.19.3 40 mm nominal bore
A) 18.19.3.1 Horizontal Each 1 1 1 1.00
18.19.3.2 Vertical Each 1 1 1 1.00
82 18.21 Providing and fixing uplasticised PVC connection pipe with brass unions :
(A) 18.21.2 45 cm length
18.21.2.1 15 mm nominal bore Each 4 2 1 8.00
83 18.22 Providing and fixing CP brass shower rose with 15 or 20 mm inlet.
(A) 18.22.1 100 mm diameter Each 4 2 1 8.00
84 18.32 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :
(A) 18.32.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Each 1 10 1 10.00
85 18.48 Providing and placing on terrace(at all floor levels) polyethylene water storage tank ISI: 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base suport for tank: per litre 4 1 1000 4000.00
86 18.54 Providing and fixing PTMT bib cock of approved quality and colour
18.54.1 15 mm nominal bore Each 4 1 3 12.00
87 18.55 Providing and fixing PTMT stop cock of approved quality and colour
18.55.2 15 mm nominal bore Each 4 2 1 8.00
88 18.56 Providing and fixing PTMT pillar cock of approved quality and colour.
18.56.2 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms each 8.00
89 18.58 Providing and fixing PTMT grating of approved quality and colour
18.58.2 Rectangular tupe with openable circular lid
18.58.2.1 150 mm nominal size square 100mm diametre of the inner hinged round grating Each
For toilets Each 4 2 1 8.00
For kitchen Each 4 1 1 4.00
For wash area Each 4 1 1 4.00
90 18.65 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. Each 4 2 1 8.00
91 19.4 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
(A) 19.4.3 180x150 mm size P type
19.4.3.2 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Each 4 1 5 20.00
92 19.7 Constructing brick masonry manhole in bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of a neat cement complete as per standard design.
19.7.1 Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total wt. of cover and frame to be not less than 38 kg. (wt. of the cover 23 kg and wt. of the frame 15 kg.)
19.7.1.2 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Each 1 6 6.00
93 19.8 Extra for depth for manholes
(A) 19.8.1 Size 90 x 80 cm
19.8.1.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Meter 9 0.5 4.50
94 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners o
A 21.1.1. fixed portion
For sliding windows SQ.MT 1 113.78 8 kg oer sq,mt 910.22
B 21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
(i) 21.1.2.3 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) SQ.M 113.78 113.78
94 21.3 Providing and fixing glazing in aluminium door, window,ventilator,shutter and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the architectual drawings and the directions of Engineer in charge(Cost of aluminium snap beading shall be paid in basic item)
B 21.3.2 With float glass panes of 5.50 mm thickness sqm
95 21.8 Filling the gap in between aluminium frame and adjacent RCC/Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in Charge complete.
21.8.1 Up to 5mm depth and 5mm width metre
96 21.15 Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete.
21.15.3 Polyester powder coated minimum thickness 50 micron aluminium Each
DW1 Each 4 3 4 48.00
97 22.5 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of:
(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surfaces.
(ii) Iind course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand ) mixed with water proofing compound in recommended prportion including rounding off junction of vertical and horizontal surfaces.
(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg per sq.m. of area.
(iv) Ivth course of 400 micron thick PVC sheet. (overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sq.m.)
Toilet floor Sq.m. 4 1.5 2.1 12.60
2nd Toilet Sq.m. 8 2.3 1.38 25.39
Add for sides- Toilet Sq.m. 4 7.5 1 30.00
98 22.7 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies terraces etc. consisting of following operations.
(a) Applying a slurry coat of neat cement using 2.75Kg/sq.m. of cement admixed with water proofing compound conforming to IS:2645 and approved by Engneer in charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.
(b)Laying brick bats with mortar using broken bricks/brick bats 25mm to 1115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineer in charge over 20mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineer in charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of the junctions of walls and slabs.
(c )After two days of proper curing applying a second coat of cement slurry using 2.75 kg/sq.m. of cement admixed with water proofing compound conforming to IS:2645 and approved by the Engineer in charge.
(d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineer in charge and finally finishing the surface with trowel with neat cement slurry and making of 300 x 300mm square 3 mm deep.
(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order & as directed and specified by the Engineer-in-charge.
22.7.1 With average thickness of 120 mm and minimum thickness at Khurra as 65mm Sq.m.
Terrace area- as per plan Sq.m. 270.00
PART-(B) : NON DSR ITEMS(NON SCHEDULED ITEM)
SL.No. Non D.S.R DESCRIPTION OF ITEM UNIT No. Length Breadth/Width Height B2(Qty for 01 block)
1 NS-1 Supply, Diluting & injecting chemical emulsion ecluding of the cost of the chemical emulsion) for PRE-CONSTRUCTIONAL ANTI TERMITE treatment and creating a continuos chemical barrier under all round the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes, conduits etc. complete as per specifications. (Plinth area of the building at ground floor only shall be measured for payment)
(A) Chloropyriphos/Lindane emulsifiable concentrate of 20% Sq.m.
Plinth area Sq.m. 270.00
2 NS-2 Providing and fixing rubber shock absorbers of minimum 25 mm dia and 40 mm length to be fixed on back side of door including screws and nuts etc. all complete. Each
3 NS-3 Providing and placing cinder/brick bat filling to the sunk floors in toilets/kitchen sunks, well compacted carefully by hand beating to required slopes including consolidation, curing, (mix shall be one part of cement mortar 4 parts of Cinder/brickbat finishing the same with the cement mortor 1:4 (1cement:4 coarse sand) by adding water proofing compound as per manufacturers recommendations including providing 25mm dia PVC drain pipe of required length. For toilet and Kitchen sunkun portions Cu.m 12 2.5 1.5 1 0.45 20.25
4 NS-4 Providing, fixing , laying, testing & commissioning (Concealed/surface mounted or underground) uPVC SWR Rigid pipes confirming to IS 13592-1992 of PRICE/SUPREME/FINOLEX or equivalent make of working pressure 6kg/sq.cm for drainage line including necessary fittings such as couplers, bends, tees, cross tees, cowls, clamps, rubber packing ring etc. confirming to DIN 19561, DIN 19534, IS 14735-99, IS-5382, joining with adhessive solvent cement including cost of jointing materials and all other necessary fixtures, fitting, air and water tight testing of the line etc. complete at all levels. (Centre line length of completed pipe line shall be measured for payment purpose)
NS-4A A 40mm outer dia. Metre
In toilets 4 3 3 36.00
In kitchen 4 1 3 12.00
NS-4B B 75mm outer dia.
In toilets Metre 4 3 2 24.00
In kitchen Metre 4 1 2 8.00
External line upto manhole for toilets Metre 4 1 8 32.00
External line upto manhole for kitchens Metre 2 1 8 16.00
NS-4C C 110mm outer dia.
In toilets Metre 4 3 1 12.00
External line upto manhole for toilets Metre 4 1 8 32.00
5 NS-8 Providing, fixing, testing and commissioning uPVC SWR Nahani trap, plain floor trap/ Multi floor trap with strainer/top cover etc. confirming to DIN 19531, DIN 19534, IS 14735-99, IS-5382 of 110 mm dia inlet and 75 mm outlet nominal dia. including fixing PVC reducer of 110mm dia. to 75 mm dia. and jointing with adhessive solvent cement including cost of cutting and making good the walls and floors at all levels etc. complete.
Toilets Each 12 12.00
Kitchen Each 4 1 1 4.00
6 NS-6 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clrestory windows using wire gauge with average width of aperture 1.4mm in both directions with wire of dia. 0.50mm all complete.
With anodised aluminium beading in aluminium window shutter leaf. Sq.m. 12 1 7 0.6 1.2 60.48
7 NS-7 Providing & fixing Hindware/Jaquar make or equivalent bathroom accessories including cutting wall/making holes and making good the surface with the same finish as directed by the Engineer in charge.
NS 7A A CP brass high flow single lever concealed diverter with body and plate for bath and shower system.
Batch cum WC Each 4 3 1 12.00
NS 7B B CP brass hand shower (Health faucet) for WC/EWC system
Batch cum WC Each 4 3 1 12.00
NS-8 Forming groove of uniform size in the external plaster surface as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge :
20 mm wide and 6 mm deep groove metre 100.00
NS-9 Providing and fixing C.P. brass towel ring of make kohler cat no- 17528T-CP or Jaquar Continental: ACN-CHR-1121N or equivalent make fixed with PVC cleats and brass screws including cutting and making good the walls wherever required complete as directed by Engineer-in-charge. Each
NS-10 Providing and Fixing Towel rack with single rail of make Jaquar -Cat No: AHS-CHR-1581 or ,kohler cat no- 17529T-CP or equivalent as approved with Rawl Plugs and brass screws complete as directed by Engineer-in-charge. Each
NS-11 Providing and fixing liquid soap dispenser horizontal /vertical matt finish with simple push lever of make Jaquar ACN-CHR-1137N or Kohler cat K -10712D-CP or equivalent as approved including cutting and making good the walls, wherever required complete as directed by Engineer-in-charge. Each
NS-12 Providing and Fixing C.P. brass Central Hole basin mixer without pop up waste system of make Jaquar Model: CON-CHR-167KNB or kohler cat no- 16027IN-4ND-CP or equivalent make as approved with 450mm long copper pipe and brass nuts including cutting and making good the walls wherever required complete as directed by Engineer-in-charge. Each
NS-13 Providing and Fixing Over head Rose shower with revolving joint (with body rotation), 115 mm long shower arm of make Jaquar Cat No: OHS-CHR-1989 or kohler cat no- 16356IN-A-CP or equivalent make as approved complete as directed by Engineer-in-charge Each 3.00
NS-14 Providing and Fixing Soap dish of make Jaquar Continental ACN-CHR-1131 N or kohler cat no- 17524T-CP or equivalent make as approved with PVC / Wooden plugs and screws including making good the walls wherever required complete as directed by Engineer-in-charge. Each 3.00
NS-15 Providing and fixing 6mm thick Clear mirror with bevelled edge on the wall over 6mm thick polycorbonate sheet with ss screw / stud, machine cut in required size, approved shade & colour etc. complete with all respect at all levels as directed by Engineer-in-charge. (Sample of Mirror shall be got approved from Engineer-in-Charge). Each
NS-16 Providing and Fixing 32mm CP Brass bottle trap complete with 250 mm long wall connecting pipe of Jaquar ALD-CHR-769 B or kohler cat no- 16407IN-CP or equivalent make as approved of size including CP Wall flange complete as directed by Engineer-in-charge. Each
NS-17 Providing and fixing white color vitreous China oval shape, under counter wash basin of make of Kohler cat. no. 2211 IN-O or jaquar FLS-WHT-0401 or equivalent as approved of 32mm dia outlet with CP Brass connection, Rubber adopter for waste connection and CI Brackets etc including cutting and making good the walls wherever required complete as per direction of engineer-in-charge. Each 3.00
NS-18 Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in alkuminium doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). SqM 15.00
NS-19 Grouting of pressed steel door frames, profile B and Profile C with CC 1:2:4(1 cement:2 sand:4 gardeded agrregate 12.5mm nominal size) CuM 3.00
9 NS-20 NS-13 : NS-01: Supply and filling of good quality moorum under floor in layers not exceeding 20 cms in depth, consolidating each deposited layer by ramming and watering, consolidating and dressing complete. (Measurement shall be based on compacted volum CU.M 1 276 0.75 207.00
NS23 Supply of earth (Excluding rock & boulder) at site including royalty,carriage and filling in specified area in layer not exceeding 200mm in depth,compacting under optimum moisture condition to achive 95% of proctor density,finishing etc.all complete for all leads and lifts,all labour,material,tools,tackle,equipments,safegaurd and incedential as nessesary as per drawing,specification and direction of Engineerin-Charge Cum 1 100 50 5000.00
POWER GRID CORPORATION OF INDIA LTD.
WRTS-II,RHQ,VADODARA
BILL OF QUNATITIES FOR type -D AS PER STANDARD TOWNSHIP DRAWING
SL.No. D.S.R 2021 Item No DESCRIPTION OF ITEM UNIT No. Length Breadth/Width Height B2 (Qty for 01 block)
PART -A SCHEDULE ITEMS - (DSR 2021)
1 1.1 Carriage of materials by mechanical transport including loading, unloading and stacking 2 14 28
1.1.2 EARTH upto 1.00 km. Cum Total excavation
3A 2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as d
2.6.1 All kind of soil cu.m
3B 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
2.8.1 All kinds of soil.
3C Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre). cu.m 27 2.5 2.50 1.00 168.75
4 2.10 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc and disposing of the suplus excavated soil as directed, within a lead of 50m:
2.10.1 All kinds of soil.
2.10.1.2 Pipes, cables etc exceeding 80 mm dia but not exceeding 300mm dia mtrs 2 30 1 30.00
5 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides, of the foundation etc. in layers not exceeding 20 cms in depth, consolidating each deposited layer by ramming and watering, lead upto 50 mtrs and lift upto 1.5 mtrs. Cu.m.
Total Excavation Cu.m. 678.91
Deduct PCC Cu.m. -21.38
Deduct RCC in footing Cu.m. -71.42
Deduct RCC in column upto plinth Cu.m. -10.62
Volume of moorum filling below foundations Cu.m. 0.00
6.1 2.26 Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked materials.
2.26.1 All kinds of Soil Cu.m.
6.2 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. Cu.m.
FILLING ABOVE GROUND As per block b1 Area 211 0.3 63.30
8 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering : All works upto plinth level.
A 4.1.8 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) Cu.m.
9 4.2 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor,etc., up to floor five level, excluding the cost of centering,shuttering and finishing :
4.2.3 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) Cum
Parapet wall top 1 70 0.23 0.115 1.85
10 4.3 Centering and shuttering including strutting, propping etc. and removalof form work for :
4.3.1 Foundations, footings, bases for columns Sqm
11 4.10 Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). sqm
At plinth level 1 70 0.23 16.10
12 4.12 Extra for providing and mixing water proofing material in cement concrete per 50 kg work in doses by weight of cement as per manufacturer's specification. per 50 kg cement 1 16.10 0.04 6.4 4.12
13 4.13 Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. sqm 1 70 0.23 16.10
14 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. sqm 1 70 0.75 52.50
15 5.9 Centring and shuttering including strutting propping etc. and removal of form for :
A 5.9.1 Foundations, footings, bases of columns etc. for mass concrete. Sq.m.
Footing pedestal 27 2 2 4 0.6 259.20
B 5.9.2 Walls (any thickness) including attached pilasters, buttresses, plinth & string courses etc. U.G.W.T. Sq.m. 1 3 2.6 7.80
C 5.9.3 Suspended floors, roofs, landings, balconies and access platform Sq.m.
FF slab + Roof Slab
Front hall area Sq.m. 1 211.00
D) 5.9.5 Lintels, beams, plinth beams, girders, bressumers & cantilevers Sq.m.
E 5.9.6 Columns, pillars, piers abutments posts & struts
RCC Columns upto plinth level Sq.m. 27 2.5 1.66 112.05
Plinth to gf slab Column Sq.m. 27 3.15 1.66 141.18
F) 5.9.7 Stairs (excluding landings) except spiral staircases.
Staircase Waiste slab- HP TO First Floor Sq.m. 2 3.155 1.50 9.47
G) 5.9.13 Vertical and horizontal fins individually or forming box louvers,bands,facias,and eaves boards. Sqm
H 5.9.15 Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like Sq.m.
Lintel beams over internal doors Sq.m. 1 30 1 0.415 12.45
I 5.9.19 Weather shade, chajjas, corbels etc. including edges. Sq.m.
Window Chajja Sq.m. 2 30 0.6 36.00
edge of chajja 2 30 0.15 9.00
16 5.11 Extra for additional height in centring &, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels over a height of 3.5 m for every additional height of 1m or part thereof (Plan area to be measured)
5.11.1 Suspended floors, roofs, landings, beams and balconies (Plan area to be measured) Sq.m. 1 1 22.48 22.48
17 NS21 Steel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in postion and binding all complete up to plinth level.
NS21 Thermo-Mechanically Treated bars Kg.
Footing Pile footing 30 71.42 2142.45
Comlumn upto plinth lvl 210 10.62 2230.011
Grad slab 65 21.10 1371.5
Plinth beam 145 21.27 3084.3414
Total for Steel upto plinth lvl KG 8828.3024
18 NS22 Steel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in postion and binding all complete above plinth level.
NS22 Thermo-Mechanically Treated bars Kg. As per standard
Columns above plinth level upto Floor V
Columns above plinth level upto Floor V 210 0.32 67.3785
19 5.30 Add for plaster drip corse/groove in plastered surface or moulding to RCC projections. Mtr.
Window chajja 2 1 70 140.00
20 5.33 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge.
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
5.33.1 All works upto plinth level
sub-total (A) 71.42
PLINTH BEAM Cu.m 2.00 18.96 0.23 0.60 5.23
Sub-total (B) 21.27
Sub-total (C) 21.10
RCC Columns upto plinth level
Sub-Total (D) 10.62 0.15 compact earth
Total 124.41 0.15 PCC
Say 124.41 0.5 Pedestal
b 5.33.2 All works above plinth level upto floor V level 2.1 Depth
GF slab level beam 0.75 Plinth
Sub-Total (A) 15.95
Staircase Waiste slab cu.m 2 3.155 1.50 0.15 1.42
Stair cabin cu.m 1 5.81 3.15 0.15 2.75
Kitchen platform slab cu.m 1 1 4 0.60 0.075 0.18
Sub-Total (B) 29.66
RCC columns from roof level to mumty parapet level cu.m 1 0.23 0.45 3.1 0.32
Sub-Total © 0.32
Total for chajja 3.75
21 5.35 Add for using extra cement in the items of design mix over and above the specified cement content therein. quintal
Upto plinth level quintal 124.41 @.50 qtl/cu.m. 62.20
Above plinth level quintal 49.69 @.50 qtl/cu.m. 24.84
22 6.1 Brick work with common burnt clay F .P .S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand)
For surface drain Cu.m. 2 70 0.23 0.3 9.66
23 6.4 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in
6.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cu.m 2 18.1 0.23 3 24.98
Less winvow 2 13.7 0.23 1.8 11.34
24 6.13 Half brick masonry with common burnt clay F .P .S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) 1 50 3.15 157.50
25 6.15 Extra for providing and placing in position 2 Nos., 6mm dia M.S. bars at every third course of half brick masonry. Sq.m. Qty same as half brick work 157.50
26.1 7.1 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge
26.2 23.7 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge
27 8.2 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
A) 8.2.1 Rajnagar plain White marble/Udaipur green marble/Zebra black marble
(i) 8.2.1.1 Area of slab upto 0.50 sqm Sq.m. 1 6 0.5 3.00
(ii) 8.2.1.2 Area of slab over 0.50 sqm Sq.m.
B) 8.2.2 Granite of any colour and shade
(i) 8.2.2.1 Area of slab upto 0.50 sqm Sq.m. 15 1 0.23 3.45
Windpw sill 32 1.5 1.8 86.40
(ii) 8.2.2.2 Area of slab over 0.50 sqm Kitchen platform Sq.m. 1 1 3 0.75 2.25
28 8.4 Extra for fixing marble /granite stone, over and above corresponding basic,item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. Metre 4 1 3 12.00
29 8.5 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. Each 1 1 1 1.00
32 9.134.1.2.1 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws ::
9.134.1.2.1 30 mm thick shutters
Main door sqm 6 1.05 2.1 13.23
33 9.46 Providning and fixing curtain rods of 1.25 mm thick chromium plated brass plate,with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs etc, wherever necessary complete:
9.46.3 25 mm dia. metre
For Windows 18 1.8 1 32.40
34 9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
9.48.2 Fixed to openings/wooden frames with rawl plugs & screws etc.
Balcony railing 49.5x49.5x3.6 Kgs. 25mm pipe 2.41 kg per meter 3 7.23
verticalsupport
@ 15kg/sq.m. of window area Kg 49.14 @15 kg/m. 737.10
35 9.119 Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer-in-Charge. metre
Toilets D3 metre 5 3 4.95 74.25
36 9.124 Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75 mm x 30 mm having wall thickness 5 mm. The styles, top & bottom rails shall have one side wall thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with M.S. tubes of size 33 mm x 17 mmx 1 mm, painted with primer , all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and the rails with a cavity, to receive single piece extruded 5 mm PVC sheet as panel. The styles and rails will be mitred cut and joint with the help of PVC solvent cement & self driven self tapping screws. Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100 mm x 8 mm complete as per manufacturer's specifications and direction of Engineer-in-charge.
9.124.2 Decorative finish (both side wood grained finish) sqm
Toilets D3 sqm 5 1 2.1 0.75 7.88
37 9.20 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face ven
9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
D1 (mumty door) Sq.m 1 1 0.90 2.10 1.89
9.22 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) SqM 5 5 0.90 2.10 47.25
9.22.1 On one side only 1 1 0.90 2.10 1.89
9.31 Providing and fixing wire gauge laminated veneer lumber shutters conforming to IS : 14616, and as per TADS 15 :2001 (Part B) using galvanised wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm as per IS :1568, for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, as per directions of Engineer-in-charge: SqM
9.31.2 30 mm thick shutters 49.14
38 10.18 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. Each 1 20 1 20.00
39 10.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Staircase railing 40 mm NB Kgs. 1 9.4 9.4 18 kg per meter 169.20 40mm pipe 3.56 kg per meter 1 3.56
25mm pipe 2.41 kg per meter 3 7.23
verticalsupport
40mm pipe 3.56 kg per meter 1 3.36
40 11.23.5 Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :
11.23.5 Udaipur green marble sqm
In landings 1 3 2.4 1.2 8.64
Entrance 1 1 2.4 1.43 3.43
41 11.24 Extra for pre finished nosing to treads of steps of marble stone. metre 1 24.00 1.5 36.00
42 11.25 Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre . Main entry sqm 5 3 0.45 6.75
43 8.31 Providing and Fixing 1st quality ceramic glazed wall tiles conforming to IS 15622(thickness to bespecified by the manufacturer) of approved make in all colours, shades except burgundy, bottle-green, black of any size as approved by the Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of Cement mortar 1:3 (1 Cement:3 Coarse Sand) and jointing with grey cement slurry @ 3.3 kg per sq m including pointing in white cement mixed with pigment of matching shade complete. Sq.m.
In dado of toilet Sq.m. 5 7.1 2.1 74.55
In dado above kitchen platform toilet Sq.m. 1 6 2.1 12.60
44 11.39 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete. Sqm
In toilet Sq.m. 5 2.5 1.5 18.75
45 11.41 Providing and laying vitrified floor tiles in different sizes(thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make in all colours and shades,laid on 20 mm thick cement mortar 1:4(1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete.
(A) 11.41.2 Size of tile 600 X 600 mm Sq.m.
As per carpet 172.5 172.5
Less toilet floor -18.75
46 11.48 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling /grouting and finishing complete as per direction of Engineer-in-charge.
11.48.2 Size of Tile 600x600 mm sqm Qty same as that of flooring 178.91
47 11.50 Deduct for not grouting the joints with white cement and matching pigmenin the items of fixing of vitrified tiles. Sqm Qty same as that of flooring 178.91
48 12.22 Making khurras 45 x 45 cm with average minimum thickness of 5cm cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1mx1mx400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete. Each 1 10 10.00
49 12.41 Providing and fixing on wall face unplasticised -Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.
( i ) Single socketed pipes
12.41.2 110 mm diameter metre 5 10 50.00
50 12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
A) 12.42.1 Coupler
B) 12.42.3 Single Tee with door
D) 12.42.6 Shoe (Plain)
51 12.43 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised -PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
52 12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams. Each 1 8 8.00
53 Providing and fixing PTMT grating of approved quality and colour.
Rectangular type with openable circular lid 18.58.2.1 150 mm nominal size square 100 mm diameter of the inner hinged round grating Each 1 8 8.00
54 13.4 12 mm cement plaster of mix : slab 6 MM
13.4.2 1:6 (1 cement : 6 coarse sand). Sq.m.
Ground Floor 190
55 13.5 15 mm cement plaster on rough side of single or half brick masonry wall of mix :
13.5.2 1:6 ( 1 cement : 6 coarse sand) Sqm.
PERIMITER Internal 1 155.05 3.3 511.665
56 13.9 Cement plaster 1:3 ( 1cement : 3 coarse sand) finished with a floating coat of neat cement :
13.9.1 12 mm cement plaster Sqm. LS 20.00
57 13.11 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 Cement : 5 Coarse sand) finished with top layer 6 mm thick cement plaster 1:6 (1 Cement : 6 Fine sand) Sq.m.
58 13.24 Extra for plastering done on moulding cornices or architraves including neat finish to line and level:
13.24.2 In two coats Sq.m. LS 180.00
59 13.26 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete Sqm Qty same as internal plaster including ceiling except staircase, stilt area 511.67 INCLUDING STAIR
61 13.47 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) Sq.m. 530.00 FULL
62 13.83 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
13.83.2 Two coats Qty same as internal plaster including ceiling except staircase, stilt area 511.67
63 13.85 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.
A 13.85.3 With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre Qty same as internal plaster including ceiling except staircase, stilt area 511.67
64 13.62.1 Painting with synthetic enamel paint, having VOC(Volatile Organic Compound ) content less than 150 grams/litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
13.62.1 Two coats Sqm
MS Work wherever required 150.00
65 16.68 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. Sq.m.
Entrance pavement Sq.m. 1 50 1 50.00
66 17.1 Providing and fixing water closet Squatting pan (Indian WC type) with 100 mm sand cast iron P or S trap, 10 litres low level white PVC flushing cistern including flush pipe with manually controlled device (handle lever) confirming to IS 7231 with all fittings and fixtures complete including, cutting and making good the walls and floors wherever required.
17.1.1 White vitreous china Orissa pattern WC pan of size 580 mm x 440 mm with integral type foot rest, Each 1 1 1 1.00
67 17.7B Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock.
(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer Each 5 1 1 5.00
68.1 8.10 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
8.10.2 Granite Stone of approved shade sq.m 3 1 0.6 1.80
68.2 17.23 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. Each
68.3 17.25 Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2" BSP thread and shapes, weighing not less than 60 gms. each
68.4 17.76 Providing and fixing PTMT urinal cock of approved quality and colour
17.76.1 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms each
68 17.10 Providing and fixing stainless steel A ISI 304(18/8) kitchen sink as per IS:13983 with CI brackets and stainless steel plug 40 mm, including painting of fittings & brackets cutting and making good the walls wherever required
17.10.1 Kitchen sink with drain board
17.10.1.4 Size 510 x 1040 bowl depth 178 mm Each 1 1 1 1.00
69 17.22A Providing and fixing PTMT Bottle Trap for Wash basin and sink Each 1 1 11 11.00
70 17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P . brass screws and washers complete. each 817.95 Each 1 5 1 5.00
71 17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality, colour and make weighing not less than 88 gms Each 1 5 1 5.00
72 17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved qualityand colour
17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm wide and effective height of 88 mm, weighing not less than 190 gms. Each 5 1 1 5.00
73 17.74 Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. Each 0 1 1 0.00
74 17.78 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover , and cistern fittings, nuts, bolts and gasket etc complete. Each 1 4 1 4.00
75 17.34 Providing and fixing toilet paper holder :
(A) 17.34.1 C.P. brass Each 4 1 1 4.00
76 17.69 Providing and fixing PTMT Waste Coupling for wash basin and sink,of approved quality and colour.
17.69.2 Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms Each 4 3 1 12.00
77 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes
18.7.2 20 mm nominal outer dia Pipes meter 50.00
18.7.4 32 mm nominal dia Pipes meter 30.00
18.7.5 40 mm nominal dia Pipes meter 10.00
78 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
A 18.8.1 15 mm nominal outer dia Pipes meter 100.00
B 18.8.2 20 mm nominal outer dia Pipes meter 50.00
79 18.17 Providing and fixing gun metal gate valve with CI wheel of approved quality (screwed end)
A 18.17.1 25 mm nominal bore each 4.00
B 18.17.2 32 mm nominal bore. each 4.00
80 18.18 Providing and fixing ball valve (brass) of approved quality High or low pressure with plastic floats complete.
18.18.3 25 mm nominal bore Each 2 1 1 2.00
81 18.19 Providing and fixing gun metal non-return valve of approved quality (screwed end)
18.19.3 40 mm nominal bore
A) 18.19.3.1 Horizontal Each 1 1 1 1.00
18.19.3.2 Vertical Each 1 1 1 1.00
82 18.21 Providing and fixing uplasticised PVC connection pipe with brass unions :
(A) 18.21.2 45 cm length
18.21.2.1 15 mm nominal bore Each 4 2 1 8.00
83 18.22 Providing and fixing CP brass shower rose with 15 or 20 mm inlet.
(A) 18.22.1 100 mm diameter Each 1 5 1 5.00
84 18.32 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :
(A) 18.32.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Each 1 7 1 7.00
85 18.48 Providing and placing on terrace(at all floor levels) polyethylene water storage tank ISI: 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base suport for tank: per litre 1 1 5000 5000.00
86 18.54 Providing and fixing PTMT bib cock of approved quality and colour
18.54.2 15 mm nominal bore Each 1 1 4 4.00
87 18.55 Providing and fixing PTMT stop cock of approved quality and colour
18.55.2 15 mm nominal bore Each 1 5 1 5.00
88 18.56 Providing and fixing PTMT pillar cock of approved quality and colour.
18.56.2 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms each 4.00
89 18.58 Providing and fixing PTMT grating of approved quality and colour
18.58.2 Rectangular tupe with openable circular lid
18.58.2.1 150 mm nominal size square 100mm diametre of the inner hinged round grating Each
For toilets Each 6.00
For kitchen Each 1.00
For wash area Each 1.00
90 18.65 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. Each 5.00
91 19.4 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
(A) 19.4.3 180x150 mm size P type
19.4.3.2 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Each 1 1 5 5.00
92 19.7 Constructing brick masonry manhole in bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of a neat cement complete as per standard design.
19.7.1 Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total wt. of cover and frame to be not less than 38 kg. (wt. of the cover 23 kg and wt. of the frame 15 kg.)
19.7.1.2 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Each 1 5 5.00
93 19.8 Extra for depth for manholes
(A) 19.8.1 Size 90 x 80 cm
19.8.1.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Meter 9 0.5 4.50
94 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners o
A 21.1.1. fixed portion
For sliding windows SQ.MT 1 49.14 8 kg oer sq,mt 393.12
B 21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
(i) 21.1.2.3 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) SQ.M 49.14
94 21.3 Providing and fixing glazing in aluminium door, window,ventilator,shutter and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the architectual drawings and the directions of Engineer in charge(Cost of aluminium snap beading shall be paid in basic item)
B 21.3.2 With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) sqm
qty w ht 0.45 #VALUE!
95 21.8 Filling the gap in between aluminium frame and adjacent RCC/Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in Charge complete.
21.8.1 Up to 5mm depth and 5mm width metre
96 21.15 Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete.
21.15.3 Polyester powder coated minimum thickness 50 micron aluminium Each
97 22.5 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of:
(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surfaces.
(ii) Iind course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand ) mixed with water proofing compound in recommended prportion including rounding off junction of vertical and horizontal surfaces.
(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg per sq.m. of area.
(iv) Ivth course of 400 micron thick PVC sheet. (overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sq.m.)
Toilet area 18.75
98 22.7 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies terraces etc. consisting of following operations.
(a) Applying a slurry coat of neat cement using 2.75Kg/sq.m. of cement admixed with water proofing compound conforming to IS:2645 and approved by Engneer in charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.
(b)Laying brick bats with mortar using broken bricks/brick bats 25mm to 1115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineer in charge over 20mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineer in charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of the junctions of walls and slabs.
(c )After two days of proper curing applying a second coat of cement slurry using 2.75 kg/sq.m. of cement admixed with water proofing compound conforming to IS:2645 and approved by the Engineer in charge.
(d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineer in charge and finally finishing the surface with trowel with neat cement slurry and making of 300 x 300mm square 3 mm deep.
(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order & as directed and specified by the Engineer-in-charge.
22.7.1 With average thickness of 120 mm and minimum thickness at Khurra as 65mm Sq.m.
Terrace area- as per plan Sq.m. 210.00
PART-(B) : NON DSR ITEMS(NON SCHEDULED ITEM)
SL.No. Non D.S.R DESCRIPTION OF ITEM UNIT No. Length Breadth/Width Height B2(Qty for 01 block)
1 NS-1 Supply, Diluting & injecting chemical emulsion ecluding of the cost of the chemical emulsion) for PRE-CONSTRUCTIONAL ANTI TERMITE treatment and creating a continuos chemical barrier under all round the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes, conduits etc. complete as per specifications. (Plinth area of the building at ground floor only shall be measured for payment)
(A) Chloropyriphos/Lindane emulsifiable concentrate of 20% Sq.m. 211.00
Plinth area Sq.m. 210.00
2 NS-2 Providing and fixing rubber shock absorbers of minimum 25 mm dia and 40 mm length to be fixed on back side of door including screws and nuts etc. all complete. Each
3 NS-3 Providing and placing cinder/brick bat filling to the sunk floors in toilets/kitchen sunks, well compacted carefully by hand beating to required slopes including consolidation, curing, (mix shall be one part of cement mortar 4 parts of Cinder/brickbat finishing the same with the cement mortor 1:4 (1cement:4 coarse sand) by adding water proofing compound as per manufacturers recommendations including providing 25mm dia PVC drain pipe of required length. For toilet and Kitchen sunkun portions Cu.m
Toilet area 18.75
4 NS-4 Providing, fixing , laying, testing & commissioning (Concealed/surface mounted or underground) uPVC SWR Rigid pipes confirming to IS 13592-1992 of PRICE/SUPREME/FINOLEX or equivalent make of working pressure 6kg/sq.cm for drainage line including necessary fittings such as couplers, bends, tees, cross tees, cowls, clamps, rubber packing ring etc. confirming to DIN 19561, DIN 19534, IS 14735-99, IS-5382, joining with adhessive solvent cement including cost of jointing materials and all other necessary fixtures, fitting, air and water tight testing of the line etc. complete at all levels. (Centre line length of completed pipe line shall be measured for payment purpose)
NS-4A A 40mm outer dia. Metre
In toilets 20.00
In kitchen 10.00
NS-4B B 75mm outer dia.
In toilets Metre 20.00
In kitchen Metre 10.00
NS-4C C 110mm outer dia.
5 NS-8 Providing, fixing, testing and commissioning uPVC SWR Nahani trap, plain floor trap/ Multi floor trap with strainer/top cover etc. confirming to DIN 19531, DIN 19534, IS 14735-99, IS-5382 of 110 mm dia inlet and 75 mm outlet nominal dia. including fixing PVC reducer of 110mm dia. to 75 mm dia. and jointing with adhessive solvent cement including cost of cutting and making good the walls and floors at all levels etc. complete.
Toilets Each 12 12.00
Kitchen Each 1 1 1 1.00
6 NS-6 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clrestory windows using wire gauge with average width of aperture 1.4mm in both directions with wire of dia. 0.50mm all complete.
With anodised aluminium beading in aluminium window shutter leaf. Sq.m. 15 1.5 1.8 1 1.2 48.60
7 NS-7 Providing & fixing Hindware/Jaquar make or equivalent bathroom accessories including cutting wall/making holes and making good the surface with the same finish as directed by the Engineer in charge.
NS 7A A CP brass high flow single lever concealed diverter with body and plate for bath and shower system.
Batch cum WC Each 4.00
NS 7B B CP brass hand shower (Health faucet) for WC/EWC system
Batch cum WC Each 4.00
NS-7C C CP Concealed flush valve 32 mm of make Jaquar FLV-CHR-1095 or equivalent make as approved complete. Each 4.00
NS-8 Forming groove of uniform size in the external plaster surface as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge :
20 mm wide and 6 mm deep groove metre 90.00
NS-9 Providing and fixing C.P. brass towel ring of make kohler cat no- 17528T-CP or Jaquar Continental: ACN-CHR-1121N or equivalent make fixed with PVC cleats and brass screws including cutting and making good the walls wherever required complete as directed by Engineer-in-charge. Each 4.00
NS-10 Providing and Fixing Towel rack with single rail of make Jaquar -Cat No: AHS-CHR-1581 or ,kohler cat no- 17529T-CP or equivalent as approved with Rawl Plugs and brass screws complete as directed by Engineer-in-charge. Each 4.00
NS-11 Providing and fixing liquid soap dispenser horizontal /vertical matt finish with simple push lever of make Jaquar ACN-CHR-1137N or Kohler cat K -10712D-CP or equivalent as approved including cutting and making good the walls, wherever required complete as directed by Engineer-in-charge. Each 4.00
NS-12 Providing and Fixing C.P. brass Central Hole basin mixer without pop up waste system of make Jaquar Model: CON-CHR-167KNB or kohler cat no- 16027IN-4ND-CP or equivalent make as approved with 450mm long copper pipe and brass nuts including cutting and making good the walls wherever required complete as directed by Engineer-in-charge. Each 4.00
NS-13 Providing and Fixing Over head Rose shower with revolving joint (with body rotation), 115 mm long shower arm of make Jaquar Cat No: OHS-CHR-1989 or kohler cat no- 16356IN-A-CP or equivalent make as approved complete as directed by Engineer-in-charge Each 4.00
NS-14 Providing and Fixing Soap dish of make Jaquar Continental ACN-CHR-1131 N or kohler cat no- 17524T-CP or equivalent make as approved with PVC / Wooden plugs and screws including making good the walls wherever required complete as directed by Engineer-in-charge. Each 4.00
NS-15 Providing and fixing 6mm thick Clear mirror with bevelled edge on the wall over 6mm thick polycorbonate sheet with ss screw / stud, machine cut in required size, approved shade & colour etc. complete with all respect at all levels as directed by Engineer-in-charge. (Sample of Mirror shall be got approved from Engineer-in-Charge). Each 4.00
NS-16 Providing and Fixing 32mm CP Brass bottle trap complete with 250 mm long wall connecting pipe of Jaquar ALD-CHR-769 B or kohler cat no- 16407IN-CP or equivalent make as approved of size including CP Wall flange complete as directed by Engineer-in-charge. Each 4.00
NS-17 Providing and fixing white color vitreous China oval shape, under counter wash basin of make of Kohler cat. no. 2211 IN-O or jaquar FLS-WHT-0401 or equivalent as approved of 32mm dia outlet with CP Brass connection, Rubber adopter for waste connection and CI Brackets etc including cutting and making good the walls wherever required complete as per direction of engineer-in-charge. Each 4.00
NS-18 Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in alkuminium doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). SqM 15.00
NS-19 Grouting of pressed steel door frames, profile B and Profile C with CC 1:2:4(1 cement:2 sand:4 gardeded agrregate 12.5mm nominal size) CuM 3.00
9 NS-20 NS-13 : NS-01: Supply and filling of good quality moorum under floor in layers not exceeding 20 cms in depth, consolidating each deposited layer by ramming and watering, consolidating and dressing complete. (Measurement shall be based on compacted volum CU.M 1 211 0.75 158.25
Control Room Building
21.1.1.1 Aluminium Window Work_Fixed Portion
Sr. No. Description of Item Section Nos. Length Total Length Unit Weight Total Weight Remarks
1 Curtain wall C1 (5x5.65) 04 nos.
Fixed Glazing Horizontal Member 22703 8 5.65 45.2 1.751 79.145
Vertical Member 22703 8 5 40 1.751 70.040
Glass Clip Horizontal Member 19377 16 5.65 90.4 0.154 13.922
Vertical Member 19377 16 5 80 0.154 12.320
2 Curtain wall C2 (2.75x2.4), 01 Nos
Fixed Glazing with Door Horizontal Member 22703 2 2.75 5.5 1.751 9.631
Vertical Member 22703 4 2.4 9.6 1.751 16.810
Glass Clip Horizontal Member 19377 4 2.75 11 0.154 1.694
Vertical Member 19377 8 2.4 19.2 0.154 2.957
3 Curtain wall C3 (3x9.35), 01 Nos
Fixed Glazing Horizontal Member 22703 11 3 33 1.751 57.783
Vertical Member 22703 4 9.35 37.4 1.751 65.487
Glass Clip Horizontal Member 19377 40 3 120 0.154 18.480
4 Curtain wall F1(3x1.65), 04 Nos
Fixed Glazing Horizontal Member 22703 8 3 24 1.751 42.024
Vertical Member 22703 8 1.65 13.2 1.751 23.113
Glass Clip Horizontal Member 19377 16 3 48 0.154 7.392
Vertical Member 19377 16 1.65 26.4 0.154 4.066
5 Ventilator V1 (1.8x0.6) 02 nos
Fixed Frame Horizontal Member 20036 4 1.8 7.2 1.139 8.201
Outer Vertical Member 20036 8 0.6 4.8 1.139 5.467
Glass Clip Horizontal Member 19377 24 0.6 14.4 0.154 2.218
Vertical Member 19377 24 0.6 14.4 0.154 2.218
Total Quantity (Kg) 460.245
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
Attach-11_Ex employee.pdf
pdf • 0.23 MB
Attach-22_Auditor.pdf
pdf • 0.13 MB
Attach-25_e-RA.pdf
pdf • 0.13 MB
Attach-26_Events.pdf
pdf • 0.23 MB
Attach-27_Landbor.pdf
pdf • 0.17 MB
Attachment 28_CIPP.pdf
pdf • 0.20 MB
Attachment-14 IP.pdf
pdf • 0.18 MB
Attachment-20_KMP_.pdf
pdf • 0.17 MB
Attachment-21_MII.pdf
pdf • 0.18 MB
Attach_23_hardcopy.pdf
pdf • 0.15 MB
Attach_32_whistle.pdf
pdf • 0.13 MB
First envelope_.xlsx
xlsx • 1.57 MB
Price_Schedule.xlsx
xlsx • 0.54 MB
Drawing ACP-1 DCP Air conditioning DB.pdf
pdf • 5.20 MB
GA Floor Plan Details of CRB.pdf
pdf • 7.21 MB
Fire alarm system drawing.pdf
pdf • 1.76 MB
Fire alarm Sys_First Floor.pdf
pdf • 0.87 MB
Fire alarm Sys_Ground Floor.pdf
pdf • 0.89 MB
Fire Protection Rev 6 (2).pdf
pdf • 1.97 MB
Post top lantern drawing.pdf
pdf • 1.00 MB
Top post laltern_annex-1.pdf
pdf • 1.00 MB
TS Air conditioning R4.pdf
pdf • 0.04 MB
TS for Civil Works.pdf
pdf • 0.21 MB
TS Lighting Panel.pdf
pdf • 0.81 MB
Commented Detail of Ground Floor and Layout RCC Detail of First Floor Slab Beam along with St.pdf
pdf • 3.72 MB
Design and Drawing of Foundation of CRB.pdf
pdf • 3.06 MB
1_VDRA-ILLUMINATION-LAYOUT_250715_133804.pdf
pdf • 1.22 MB
Annexure-3 (SFQP for Site awarded package).pdf
pdf • 2.86 MB
Annexure-4 (TS Rev 11A).pdf
pdf • 5.21 MB
Annexure -C(BDS)_.pdf
pdf • 0.18 MB
Annexure -D (BDS) e-Reverse Auction - Bidder Manual.pdf
pdf • 2.00 MB
Annexure -E EMD format (BDS ).pdf
pdf • 0.17 MB
Annexure- B ERABDS.pdf
pdf • 0.14 MB
QR for New CRB.pdf
pdf • 0.07 MB
Sec - I IFB.pdf
pdf • 0.31 MB
Sec- III BDS.pdf
pdf • 0.20 MB
Section - II ITB.pdf
pdf • 0.53 MB
Section - IV GCC.pdf
pdf • 0.59 MB
Section - V SCC.pdf
pdf • 0.17 MB
Section - VIAppd_SCC.pdf
pdf • 0.42 MB
~$RD3019.tmp
tmp • 0.00 MB
~WRL0007.tmp
tmp • 0.09 MB
~WRL0111.tmp
tmp • 0.09 MB
~WRL2356.tmp
tmp • 0.09 MB
~WRL3792.tmp
tmp • 0.09 MB
~WRL3932.tmp
tmp • 0.09 MB
~WRL4029.tmp
tmp • 0.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .