Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 2 KALKAJI INDUSTRIAL AREA KALKAJI KALKAJI SOUTH DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹74.5 L
EMD Value
₹1.5 L
Closing Date
28 Sept 2024, 2:00 pmClosed
GM HWP Tuticorin
HWP Tuticorin
Supply and application of thermal insulation in 11th 12th unit for vessels and pipelines
2024_HWB_826018_1
HWPT/MECH/2024/1005
Open Tender
Oil/Gas
Works
240 days
HWP Tuticorin
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹1.5 L
Yes
15 Oct 2024
14 Sept 2024
30 Sept 2024
14 Sept 2024
28 Sept 2024
15 Sept 2024
Amount
Inhibited Rockwool pre-formed/Machine Laid machine stitched(LRB) having density 128 Kg/M3SS Hexagonal Wire Netting of size 3/4" x 22 SWG & Additional layer GI wire netting of size 3/4"X 22 SWG IS: 9842 for pipelines up to 2" NB as per thickness mentioned below 1/2"NB XTHICK 80MM
1/2"NB XTHICK 60 MM
1/2"NB XTHICK 50 MM
1/2"NB XTHICK 100 MM
3/4 "NB XTHICK 60MM
1"NB XTHICK 100 MM
1"NB XTHICK 60 MM
1"NB XTHICK 80 MM
1.25"NB XTHICK 80 MM
1.25"NB XTHICK 60 MM
1.5 "NB XTHICK 60MM
1.5 "NB XTHICK 80 MM
2"NB XTHICK 50 MM
2"NB XTHICK 60 MM
2"NB XTHICK 80 MM
Supply and apply of Inhibited Lightly Resin Bonded Machine Laid machine stitched Rockwool Mattresses (LRB) having density 128 Kg/m3 backed with one side SS Hexagonal Wire Netting of size 3/4" x 22 SWG for pipelines above 2" NB. For insulation thicknes up to 75mm it shall be of single layer and above 75mm it shall be of two layers in equal thickness wherever possible. This material shall conform to IS: 8183. 3" NB XTHICK 50MM
4" NBX THICK80MM
6" NBX THICK60MM
5" NBX THICK80MM
5" NBX THICK60MM
6" NBX THICK80MM
8" NBX THICK80MM
8" NBX THICK100MM
8" NBX THICK50MM
10" NBX THICK80MM
Supply and apply of Cast-in-Situ(injection method) Polyurethane Foam Insulation having density 48 ±2 Kg/cum in required thicknesses for pipelines. This material shall conform to IS: 13205.Thickness of the insulation is as mentioned below 1/2" NBX THICK 80MM
1/2" NBX THICK 30MM
1/2" NBX THICK 25MM
1/2" NBX THICK 50MM
1/2" NBX THICK 65MM
1/2" NBX THICK 100MM
1/2" NBX THICK 80MM
3/4" NBX THICK 90MM
3/4" NBX THICK 75MM
3/4" NBX THICK 50MM
1" NBX THICK 60MM
1" NBX THICK 25MM
1" NBX THICK 100MM
1" NBX THICK 220MM
1" NBX THICK 75MM
1" NBX THICK 50MM
11/2" NBX THICK 60MM
1 1/2" NBX THICK 50MM
2" NBX THICK 60MM
2" NBX THICK 65MM
2" NBX THICK 50MM
3" NBX THICK 100MM
3" NBX THICK 60MM
3" NBX THICK 50MM
3" NBX THICK 75MM
4" NBX THICK 50MM
4" NBX THICK 75 MM
5" NBX THICK 60MM
5" NBX THICK 50MM
6" NBX THICK 50 MM
8" NBX THICK 100MM
8" NBX THICK 50MM
8" NBX THICK 75MM
8" NBX THICK 60MM
10" NBX THICK 60MM
10" NBX THICK 100 MM
10" NBX THICK 75 MM
10" NBX THICK 50 MM
10" NBX THICK 90MM
12" NBX THICK 100MM
Supply and apply of Inhibited Lightly Resin Bonded Machine Laid machine stitched Rockwool Mattresses (LRB) having density 128 Kg/m3 backed with one side SS Hexagonal Wire Netting of size 3/4" x 22 SWG for the vessels / equipments mentioned below. For insulation thickness up to 75mm it shall be of single layer and above 75mm it shall be of two layers in equal thickness wherever possible. This material shall conform to IS: 8183. AEA101 THICK 100 MM
Supply and apply of Cast-in-Situ(injection method) Polyurethane Foam Insulation having density 48 ±2 Kg/cum in required thicknesses for equipments. This material shall conform to IS: 13205.Thickness of the insulation is as mentioned below 11R2 THICK 160MM
12T1 THICK 220 VESSEL
12T1 THICK 400 FLANGE
AEA201 THICK 100MM VESSEL
AEA104 THICK 100MM
AFA101 THICK 75 MM
Supply of anti-condensate tape and application/applying to the pipe lines in different sizes and thickness, 1/2 " NB XTHICK 3 TO 6MM
1" NBX THICK 3 TO 6MM
2 1/2" NB X THICK 3-6 MM
Removal of hot insulation up to 6 " NB
Removal of hot insulation of above 6 " NB
Removal of cold insulation up to 6"NB
Removal of cold insulation ABOVE 6"NB
Removal of hot insulation from equipmet
Removal of cold insulation from equipmet
Erection and de-erection of scaffolding at various locations in the plant required for application of paint & insulation.
Mechanised surface cleaning using flap wheel machine , application of two coats of 30 micron thick each bituminous black/heat resistant aluminium paint for pipelines / equpments prior to application of hot/cold insulation.
Supply of bitumionus black paint as per IS:3384
Supply of heat resistance aluminium paint for temperature up to 600 deg C as per IS:3384
LLOYD INSULATIONS (INDIA) LIMITED
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .