Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC TEHSIL SARKAGHAT P O RAKHOH VILL GADHANI SARKAGHAT MANDI HP 175024 | MANDI | HIMACHAL PRADESH | 175024 | ₹12.5 L Quoted ₹12.9 L | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER |
| 2 | L2₹16.3 L+₹3.5 L (26.9%)Rejected-Finance PLOT NO 86 SHIVAM PARK 2 AIR PORT ROAD BEHIND SANATAN MANDIR BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | ₹16.3 L+₹3.5 L (26.9%) | L2 | Rejected-Finance REJECTED BEING NOT LOWEST TENDER |
| 3 | L3₹16.8 L+₹3.9 L (30.5%)Rejected-Finance | ₹16.8 L+₹3.9 L (30.5%) | L3 | Rejected-Finance REJECTED BEING NOT LOWEST TENDER |
| 4 | L4₹17.0 L+₹4.2 L (32.5%)Rejected-Finance | ₹17.0 L+₹4.2 L (32.5%) | L4 | Rejected-Finance REJECTED BEING NOT LOWEST TENDER |
| 5 | L5₹18.0 L+₹5.1 L (39.9%)Rejected-Finance | ₹18.0 L+₹5.1 L (39.9%) | L5 | Rejected-Finance REJECTED BEING NOT LOWEST TENDER |
| Sl No | Description | Qty | Unit | shivrefrigeration L6 | Pal Engineering Services L5 | MAHADEV ELECTRICALS L3 | VATANUCOOL ENGINEERS L1 | PANTECH INSTRUMENTS AND SERVICES L4 | JYOTI TRADERS L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Disconnecting, dismantling of air cooled Packaged type AC Plant 16.5 TR capacity complete with indoor and out door unit, strip opening, cleaning & descaling complete with dust cleaning equipment and servicing of the AC plant with using caustic soda/detergent powder solution, taking out and removing unserviceable/defective minor parts & wiring , painting the bottom with one coat of black synthetic enameled paint of out-door unit, replacement of air filters, belt and replacement of the unserviceable and defective minor parts, heater, brazing, reassembling and testing of the AC plant complete all as specified and directed. NOTE :- (i) The defective/nonfunctional minor parts will be replaced by the contractor under the unit rate quoted for this item. (ii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item. | 3 | Each job | 7,500 ₹22,500 | 3,000 ₹9,000 Lowest | 10,000 ₹30,000 | 5,000 ₹15,000 | 5,000 ₹15,000 | 6,250 ₹18,750 |
| 2.00 | Supply of lubricating oil anti freezing for refrigeration in factory sealed container of standard capacity for filling under Sch ‘A’ items No 1 complete,all as specified and directed. Make: Servo froze -68-10c of IOC. | 10 | Per Litre | 550 ₹5,500 | 444 ₹4,440 | 500 ₹5,000 | 200 ₹2,000 Lowest | 400 ₹4,000 | 650 ₹6,500 |
| 3.00 | Supply fixing and testing in replacement of UNSV liquid line filtter driers of suitable size for Package type AC plant 16.5TR complete all as specified & directed. | 2 | Each | 2,000 ₹4,000 | 999 ₹1,998 | 1,200 ₹2,400 | 900 ₹1,800 Lowest | 1,000 ₹2,000 | 1,200 ₹2,400 |
| 4.00 | Supply and fixing/testing in replacement of UNSV V belt 'A' type as per existing for blower fan of packege type unit complete, all as specified and directed. | 2 | Each Job | 500 ₹1,000 | 333 ₹666 | 350 ₹700 | 300 ₹600 Lowest | 400 ₹800 | 550 ₹1,100 |
| 5.00 | Supply and fixing/testing in replacement of UNSV compressore 5.5 tr make denfoss/copland scroll compressore R-407 with pressure testing complete, all as specified and directed. | 1 | Each Job | 65,000 ₹65,000 | 55,555 ₹55,555 | 55,000 ₹55,000 | 5,000 ₹5,000 Lowest | 40,000 ₹40,000 | 95,000 ₹95,000 |
| 6.00 | Disconnecting & taking out existing defective blower motor Package type AC Plant of any description & in any position of size 2/3 HP, 415 volts strip opening for rewinding, removing for rewinding to & from to workshop, rewinding with appropriate size copper super enameled wire (Make : Atlas /Finolex /Devi Dayal ) including suitable bearing, insulating material such as illuminous paper, Leatherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation & fixing the motor at site including necessary connecting & testing at site complete all as specified and directed. | 3 | Each | 4,400 ₹13,200 | 5,555 ₹16,665 | 8,500 ₹25,500 | 4,000 ₹12,000 Lowest | 5,000 ₹15,000 | 4,700 ₹14,100 |
| 7.00 | Supply and fixing/testing in replacement of UNSV blower motor Package type AC Plant of any description & in any position of size 2/3 HP, 415 volts suitable for package type plant 16.5 TR | 1 | Each | 3,200 ₹3,200 | 4,444 ₹4,444 | 6,000 ₹6,000 | 3,000 ₹3,000 Lowest | 6,000 ₹6,000 | 3,690 ₹3,690 |
| 8.00 | M&L for replacement of unserviceable remote control assembly with PCB plate complete with connections suitable for Package type AC 16.5 TR three phase capacity complete all as specified and directed .(Make : Carrier/Hitachi/LG ) | 1 | Each | 1,650 ₹1,650 Lowest | 16,780 ₹16,780 | 3,200 ₹3,200 | 15,000 ₹15,000 | 3,500 ₹3,500 | 15,450 ₹15,450 |
| 9.00 | M&L for replacement of unserviceable condensing coil unit for Package type AC of any type/ any capacity complete, all as specified and directed by Engr-in-charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH ) | 2 | Each | 1,670 ₹3,340 | 1,678 ₹3,356 | 2,500 ₹5,000 | 1,500 ₹3,000 | 2,000 ₹4,000 | 1,400 ₹2,800 Lowest |
| 10.00 | Supply, fixing, connecting and testing in replacement of UNSV thermostate heating/cooling of any description complete,all as specified and directed. | 3 | Each Job | 1,340 ₹4,020 | 1,212 ₹3,636 | 200 ₹600 Lowest | 1,200 ₹3,600 | 250 ₹750 | 1,212 ₹3,636 |
Tender Value
₹18.4 L
EMD Value
₹36,800
Closing Date
13 Jul 2026, 6:00 pmClosed
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
REPAIR/MAINT OF EXTERNAL E/M SERVICES OF WATER ELECTRIC SUPPLY INCL CERTAIN OTHER REPAIRS ACS, WATER COOLERS AND INTERNAL ELECTRIC SUPPLY OF BUILDING INCLUDING SUBMAIN, DB AND ALLIED WORKS IN TECHNICAL AND RESIDENTIAL AREA CQA (I) RAIPUR DEHRADUN
2026_MES_774046_1
GE(I)RND/9591/E8/26-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Dehradun
As per tender documents
7 documents required · 7 mandatory
₹500
GE I RND DEHRADUN
₹36,800
Yes
12 Sept 2026
22 Jun 2026
15 Jul 2026
22 Jun 2026
13 Jul 2026
6 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Disconnecting, dismantling of air cooled Packaged type AC Plant 16.5 TR capacity complete with indoor and out door unit, strip opening, cleaning & descaling complete with dust cleaning equipment and servicing of the AC plant with using caustic soda/detergent powder solution, taking out and removing unserviceable/defective minor parts & wiring , painting the bottom with one coat of black synthetic enameled paint of out-door unit, replacement of air filters, belt and replacement of the unserviceable and defective minor parts, heater, brazing, reassembling and testing of the AC plant complete all as specified and directed. NOTE :- (i) The defective/nonfunctional minor parts will be replaced by the contractor under the unit rate quoted for this item. (ii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item. | 3 | Each job | - | - |
| 2 | Supply of lubricating oil anti freezing for refrigeration in factory sealed container of standard capacity for filling under Sch ‘A’ items No 1 complete,all as specified and directed. Make: Servo froze -68-10c of IOC. | 10 | Per Litre | - | - |
| 3 | Supply fixing and testing in replacement of UNSV liquid line filtter driers of suitable size for Package type AC plant 16.5TR complete all as specified & directed. | 2 | Each | - | - |
| 4 | Supply and fixing/testing in replacement of UNSV V belt 'A' type as per existing for blower fan of packege type unit complete, all as specified and directed. | 2 | Each Job | - | - |
| 5 | Supply and fixing/testing in replacement of UNSV compressore 5.5 tr make denfoss/copland scroll compressore R-407 with pressure testing complete, all as specified and directed. | 1 | Each Job | - | - |
| 6 | Disconnecting & taking out existing defective blower motor Package type AC Plant of any description & in any position of size 2/3 HP, 415 volts strip opening for rewinding, removing for rewinding to & from to workshop, rewinding with appropriate size copper super enameled wire (Make : Atlas /Finolex /Devi Dayal ) including suitable bearing, insulating material such as illuminous paper, Leatherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation & fixing the motor at site including necessary connecting & testing at site complete all as specified and directed. | 3 | Each | - | - |
| 7 | Supply and fixing/testing in replacement of UNSV blower motor Package type AC Plant of any description & in any position of size 2/3 HP, 415 volts suitable for package type plant 16.5 TR | 1 | Each | - | - |
| 8 | M&L for replacement of unserviceable remote control assembly with PCB plate complete with connections suitable for Package type AC 16.5 TR three phase capacity complete all as specified and directed .(Make : Carrier/Hitachi/LG ) | 1 | Each | - | - |
| 9 | M&L for replacement of unserviceable condensing coil unit for Package type AC of any type/ any capacity complete, all as specified and directed by Engr-in-charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH ) | 2 | Each | - | - |
| 10 | Supply, fixing, connecting and testing in replacement of UNSV thermostate heating/cooling of any description complete,all as specified and directed. | 3 | Each Job | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
Tenderdocuments.pdf
Tender Documents • 0.85 MB
BOQ_866738.xls
BOQ • 3.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .