Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
29 Jul 2022, 6:00 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2022_MES_527893_2
GE MAINT EZHIMALA 8477
Open Tender
Civil Works
Item Rate
330 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹40,000
Yes
18 Aug 2022
1 Jul 2022
1 Aug 2022
1 Jul 2022
29 Jul 2022
8 Jul 2022
2 Jul 2022 - 5 Jul 2022
Amount
Comprehensive maintenance including repairs but excluding spare parts as required for all the SCADA equipment as described below:- (a) Servicing and maintenance of components of PLC based control panels including all accessories modem, antenna etc. installed at various pump houses,sumps and master control station. The scope of work also covers:- (i) Maintenance and operation of SCADA based water supply pumping and distribution system, including servicing of all the Programmable Logic Control based Control Panels, checking the circuits,changing the time of pumps/valves from the control panel/ SCADA system. (ii) Manual/ Remote operations from the Control panel/ SCADA System - 01 Nos highly skilled Technician /shift of 8hrs in three shifts,he shall report to JE E/M or Engr-in-charge daily including sundays and holidays. Contractor should follow as per labour laws for attending the SCADA maintenance and operation.The payment to high skilled technician is included in this quoted rate. (iii) If contractor failed to provide the highly skilled technician in shift wise for three shifts on daily basis as per labour law (including sundays and holidays), then a recovery of 1500/- per shift will be penalised. (iv)The technician should be having the trained certificate from the control panel manufacturer.
(b) The quoted rate is deemed to include the charges for communication for all the existing SIM cards used in PLC based control panel. (c) The rate also include the charges for the existing broad band connection with static IP(BSNL) at RL 30 pump house. (d)The servicing and repair of motorised valves, PLC based control Panels, communication Panels, Mimic Panels shall be done by authorized representative of the manufacturer only. (e)The programmer shall submit a letter from the manufacturer as proof of his being a authorized representative of the manufacturer.The technician shall also submit a signed report on original letter head of the manufacturer that servicing has been carried out by him. (f) Any changes to the Programmable Logic Controller(PLC), e.g. Changes in ladder logic of programme, changes in operational timing, etc. (limited to the scope of work covered under this AMC) shall be carried out by authorized representative of the manfacturer of PLC based Panels only. (g) Any changes to the SCADA software, e.g. Changes in report format, changes in operational screens, creation of soft keys etc. (limited to the scope of work covered under this AMC) shall be carried out by authorized representative of the Manufacturer of PLC based Panels only. (h) SCADA reports related to all the systems to be mailed to JE / Engr-in-charge on monthly basis. (j)To attend break down maintenance( within 2 hours of reported time) and replacement of unserviceable spare parts as required at site complete all as specified and directed by Engineer in charge. (k) All components/spare parts replaced shall be measured and paid separately as per item mentioned in below schedule .All minor maintenance repair works of SCADA are to be attended by the technician who is in duty. (l) All the calls related to unserviceability/ break down of the system should be attended within 2 hours.
Supply and fix in repair/replacement of Single Phasing Preventor complete all as specified and directed. Make:- MINILEC Part No. :- VSPD2 or equivalent in L&T.
Supply and fix in repair/replacement of Relay with base - 4 C/O, 240V DC complete all as specified and directed. Make:- IDEC (Part No. :- RU4S-A220) or equivalent in LEONE/ Omron.
Supply and fix in repair/replacement of Relay with base - 4 C/O, 24V DC complete all as specified and directed. Make:- IDEC (Part No. :- RU4S-D24) or equivalent in LEONE/ Omron.
Supply and fix in repair/replacement of LED Indicators of Colour : Red/Yellow/ Green complete all as specified and directed. Make:- TELEMECHANIQUE (Part No. :- Red-XB7-EV 04 MPN,Yellow-XB7-EV 05 MPN,Green-XB7-EV 03 MPN) or equivalent in ESBEE/TEKNIC.
Supply and fix in repair/replacement of LED Indicators of Colour : Blue complete all as specified and directed. Make:- TELEMECHANIQUE (Part No. :- XB7-EV 06 MPN) or equivalent in ESBEE /TEKNIC.
Supply and fix in repair/replacement of Pressure Transmitter complete all as specified and directed. Make: DANFOSS (Part No. :- 060G1133MBS3000 (0-16 Bar)) or equivalent in INDFOSS.
Supply and fix in repair/replacement of Push Button with LED Indicator – 240V A.C, Colour : Red / Yellow / Green. complete all as specified and directed. Make:-TELEMECHANIQUE (Part No. :- Red-XB5-AW 34 M 2 N,Yellow-XB5-AW 35 M 1 N,Green-XB5-AW 33 M 1 N) or equivalent in TEKNIC/ ESBEE.
Supply and fix in repair/replacement only NO Contact - 240V A.C.,3 A complete all as specified and directed. Make:-TELEMECHANIQUE (Part No. :- 2BE-101N) or equivalent in TEKNIC/ ESBEE/L&T.
Supply and fix in repair/replacement only NC Contact - 240V A.C.,3 A complete all as specified and directed. Make:-TELEMECHANIQUE (Part No. :- 2BE-102N) or Equivalent in TEKNIC/ ESBEE/L&T.
Supply and fix in repair/ replacement SMPS Input Voltage: 230 V, Output Voltage: 24 V complete all as specified and directed. Make:- NHP (Part No. :- NHP-ES-240) or equivalent in TELEMECHANIQUE.
Supply and fix in repair/ replacement of Programmable Logic Controller complete all as specified and directed. Make:- MESSUNG or as equivalent as approved by GE. Note:- Downloading and uploading of the PLC Programs carried out only in the presence of authorized panel manufacturer and the Engineer in charge.
Supply and fix in repair/replacement of I/O Module complete all as specified and directed. Make:- MESSUNG (Part No. :- NEXGENIE-2000) or equivalent in INDFOSS/ Unitronics. Note:- Replacement of the I/O Module should be carried out without harming the existing PLC Programme and in the presence of authorized panel manufacturer and the Engineer in charge.
Supply and fix in repair/ replacement of wireless modem complete all as specified and directed. Make:- MAESTRO HERITAGE (Part No. :- M1003G) or equivalent in LEO/MAXON
Supply and fix in repair/ replacement of antenna for wireless communication complete all as specified and directed. Make:- KENSTEL (Part No. :- KSA-5800) or equivalent in MAXON.
Supply and fix in repair/replacement of transformer input voltage: 230v AC Output voltage: 12V AC 3 phase complete all as specified and directed. Make:- AIM or equivalent in L&T/ABB/Legrand/Schneider.
Supply and fix in repair/replacement of MCB 3P,10 A complete all as specified and directed. Make:- HAVELLS ( Part No. :- Havells C10) or equivalent in L&T/ TELEMECHANIQUE
Supply and fix in repair/replacement of Ultrasonic Level Sensor complete (sensing element for ULS Part No. QT50ULB of make- BANNER and PCB for ULS Part No. 20010973 of BANNER) as specified and directed. Make:- BANNER (Part No. QT 50 ULB P/N 2726 ) or equivalent in Endress+Hauser/Siemens.
Supply and fix in repair/replacement of electric motor suitable for actuator for 150mm dia butterfly valve complete all as specified and directed. Make:- RITETORK ( Part No. RT 10) or equivalent in MARSH/ Mitsubishi/ Grundfos.
Supply and fix in repair/replacement of electric motor suitable for actuator for 200mm dia butterfly valve complete all as specified and directed. Make:- RITETORK ( Part No. RT 20) or equivalent in MARSH/ Mitsubishi/ Grundfos.
Supply and fix in repair/replacement of electric motor suitable for actuator for 300 mm dia butterfly valve complete all as specified and directed. Make:- RITETORK ( Part No. RT 30) or equivalent in MARSH/ Mitsubishi/ Grundfos.
Supply and fix in repair/replacement of M.S. spiral gear for gear box of actuator for 100mm dia butterfly valve complete all as specified and directed. Make: RITETORK ( Part No. Worm RT 5) or equivalent in MARSH/ Mitsubishi/ Grundfos.
Supply and fix in repair/replacement of M.S. spiral gear for gear box of actuator for 150mm dia butterfly valve complete all as specified and directed. Make:- RITETORK ( Part No. Worm RT 10) or equivalent in MARSH/ Mitsubishi/ Grundfos.
Supply and fix in repair/replacement of M.S. spiral gear for gear box of actuator for 200mm dia butterfly valve complete all as specified and directed. Make:- RITETORK ( Part No. Worm RT 20) or equivalent in MARSH/ Mitsubishi/ Grundfos.
Supply and fix in repair/replacement of M.S. Spiral gear for gear box of actuator for 300mm dia butterfly valve complete all as specified and directed. Make:- RITETORK ( Part No. Worm RT30) or equivalent in MARSH/ Mitsubishi/ Grundfos.
Supply and fix butterfly valve of size 100 mm dia complete all as specified and directed. Make:- AUDCO ( Part No. IBFLPC100) or Equivalent in VIRGO/ INTERVALVE/ LEADER/ZOLOTO/SANT/L&T/KIRLOSKAR.
Supply and fix butterfly valve of size 150 mm dia complete all as specified and directed. Make:- AUDCO ( Part No. IBFLPC150) or Equivalent in VIRGO/ INTERVALVE/ LEADER/ZOLOTO/SANT/L&T/KIRLOSKAR.
Supply and fix butterfly valve of size 200 mm dia complete all as specified and directed. Make:- AUDCO ( Part No. IBFLPC200) or Equivalent in VIRGO/ INTERVALVE/ LEADER/ZOLOTO/SANT/L&T/KIRLOSKAR.
Supply and fix butterfly valve of size 300 mm dia complete all as specified and directed. Make:- AUDCO ( Part No. IBFLPC300) or Equivalent in VIRGO/ INTERVALVE/ LEADER/ZOLOTO/SANT/L&T/KIRLOSKAR.
Supply and fix in repair/replacement of capacitor for actuator suitable for 100/150/ 200/300mm dia butterfly valve complete all as specified and directed. Make:- L&T/HAVELLS/LEGRAND/SCHNEIDER.
Supply and fix in repair/replacement of resistor for actuator suitable for 100/150/ 200/300mm dia butterfly valve complete all as specified and directed. Make:- L&T/HAVELLS/LEGRAND/SCHNEIDER.
Supply and fix in repair/replacement of hand wheel for actuator suitable for 100/ 150/200/300mm dia butterfly valve complete all as specified and directed.
Supply and fix in repair/replacement of limit switch for actuator suitable for 100 / 150/200/300mm dia butterfly valve complete all as specified and directed. Make:- L&T/HAVELLS/LEGRAND/SCHNEIDER.
Supply and fix in repair/replacement of top cover for actuator suitable for 100mm/ 150mm/200mm/300 mm dia butterfly valve complete all as specified and directed. Make:- AUDCO/VIRGO/ INTERVALVE/LEADER /ZOLOTO/SANT / L&T/ KIRLOSKAR.
Supply and fix in repair/replacement of 6 Core 1.5sq.mm. dia. armoured cable complete all as specified and directed. Make:- POLYCAB/ HAVELLS/ FINOLEX
Supply and fix in repair/replacement of battery for 1.1 KVA UPS complete all as specified and directed. Make:- Exide/Amaron
Supply and fix HMI for programmable logic controller complete all as specified and directed. Make:- Mitsubishi, Siemens or existing make/brand of defective components/ spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
CIMCON SOFTWARE INDIA PVT. LTD.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .