| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 CrAccepted-AOC | ₹13.7 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹13.8 CrRejected-Finance | ₹13.8 Cr | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹13.9 CrRejected-Finance 121 MODEL TOWN AMBALA CITY HARYANA 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | ₹13.9 Cr | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹14.8 CrRejected-Finance NOT SPECIFIED | ₹14.8 Cr | L4 | Rejected-Finance NOT LOWEST |
| 5 | L5₹16.1 CrRejected-Finance | ₹16.1 Cr | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹12.8 Cr
EMD Value
₹9.6 L
Closing Date
24 Jan 2023, 6:00 pmClosed
CE (AF) WAC PALAM
HQ CE (AF) WAC PALAM DELHI CANTT-10
PROVISION OF EXTERNAL SERVICES AT AF STN AMBALA
2022_MES_513820_5
CEWAC/AMB/T-14/2021-22
Open Tender
Civil Works
365 days
GE (P) (AF) AMBALA
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
Yes
GE (P) (AF) AMBALA
₹9.6 L
Yes
14 Feb 2023
4 Jan 2023
26 Jan 2023
4 Jan 2023
24 Jan 2023
11 Jan 2023
Amount
SCHEDULE `A' PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.00 under column 5 signifies this fact only.
Construction of Pump House with permanent specification and as shown on drawings complete.
Construction of Ramp for 3D Car with permanent specification and as shown on drawings complete.
Construction of Under Ground Sump 50KL (50000 Ltrs) capacity with permanent specification and as shown on drawings complete.
Construction of Static Water Tank (SWT) 40000 Ltrs capacity with permanent specification and as shown on drawings complete.
Construction of Fire Point Shed as shown on drawings complete.
Construction of Septic Tank for 10 users complete all as specified and shown on drawings.
Construction of Soakage well 1.2 M x 3.0 M deep complete all as specified and shown on drawings.
NOTE: Schedule ‘A’ Part II to XII under Ser No 2.01 to 2.10 are Prepriced by MES.
Lump sum price worked out by the Contractor for “SITE CLEARANCE AND EARTH WORK” as listed in Schedule ‘A’ Part II
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part III
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part IV
Lump sum price worked out by the Contractor for "SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part V
Lump sum price worked out by the Contractor for “AREA DRAINAGE " as listed in Schedule ‘A’ Part VI
Lump sum price worked out by the Contractor for “ROAD, PATH AND CULVERT ” as listed in Schedule ‘A’ Part- VII
Lump sum price worked out by the Contractor for “FENCING AND GATE ” as listed in Schedule ‘A’ Part- VIII
Lump sum price worked out by the Contractor for “SHIFTING OF WATCH TOWER ” as listed in Schedule ‘A’ Part- IX
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - X
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - XI
Lump sum price worked out by the Contractor for "DEMOLITION AND DISMANTLING” as listed in Schedule ‘A’ Part XII
SCHEDULE `A' PART - XII MISC ITEMS (B/R & E/M) is not prepriced by MES and prepriced rates indicate 0.00 under column 5 signifie this fact only.
INTERNAL ELECTRIFICATION
S&F LED security light fitting 15 Watt, input 110 to 220 Volts as per IP 65 luminaries comprsing of rectangular shape, high pressure die cast aluminium housing with weather proof gaskets for lamp and driver compartment with GI pipe 25 mm dia light grade bend to shape including necessary fixing arrengement complete all as specified and as directed.
S&F stepped type electronic fan regulator flush type suitable for upto 1200 mm ceiling fan on the laminated white sheet etc all as specifed and as directed.
S&F MCB SPN 32 Amps, B curve type 10 KA, 240 Volts complete all as specified and as directed.
EXTERNAL ELECTRIFICATION
Supply, Install, test & commissioning copper wound step down transformer oil filled , ONAN, Dyn 11, delta star type, insulation class F Outdoor type, HT, 11 KV, 3 phase, LT, 433 V, 3 phase , 4 wire with off load tapings on primary side to vary secondary voltage +-7.5 % with tapings at every 2.5% step with max losses at 50% loading 2620 Watt and at 100% loading 7000 Watts as per IS-1180 of capacity 1000 KVA Complete all as specified and including of following:- (A) Three nos procelain bushings HT 11 KV brass busing rods, nuts and washers with cable end box. (b) Cable box LV side and HV side consisting of 4 Nos procelain bushings with brass bushing rods, complete with nuts and washers with four nos Cable glad suitable LT/UG Cable. (c) Oil conservator with filter type drain valve and oil level indicator. (d) Dehydrating breather with first fill of dehydrating agent. (e) Pressure relief valve.
Supply, Install, test & commissioning copper wound step down transformer oil filled , ONAN, Dyn 11, delta star type, insulation class F, Outdoor type, HT, 11 KV, 3 phase, LT, 433 V, 3 phase , 4 wire with off load tapings on primary side to vary secondary voltage +- 7.5% with tapings ar every 2.5% with max loses at 50% loading 670 Watts at 100% loading 2100 Watts as per IS-1911 , lifting lugs 02 Nos and 02 Nos earth terminals bidirectional rollers all as IS 11171 of capacity 200 KVA Complete all as specified and including of following:- (A) Three nos procelain bushings HT 11 KV brass busing rods, nuts and washers with cable end box. (b)Cable box on HV and LV side consisting of 4 Nos procelain bushings with brass bushing rods, complete with nuts and washers with four nos Cable glad suitable LT/UG Cable. (c) Oil conservator with filter type drain valve and oil level indicator. (d) Dehydrating breather with first fill of dehydrating agent. (e) Pressure relief valvs.
Supply, Install, test & commissioning copper wound step down transformer oil filled ONAN, Dyn 11, delta star type, insulation class F, Outdoor type, HT, 11 KV, 3 phase, LT, 433 V, 3 phase , 4 wire with off load tapings on primary side to vary secondary voltage +-7.5% with tapings ar every 2.5% with max loses at 50% loading 300 Watts at 100% loading to 1050 Watts as per IS 1050 of capacity 63 KVA Complete all as specified and including of following:- (A) Three nos procelain bushings HT 11 KV brass busing rods, nuts and washers with cable end box, (b) Cable box on HV and LV side consisting of 4 Nos procelain bushings with brass bushing rods, complete with nuts and washers with four nos Cable glad suitable LT/UG Cable. (c) Oil conservator with filter type drain valve and oil level indicator. (d) Dehydrating breather with first fill of dehydrating agent. (e) Pressure relief valve
Supply, Installation commissioning of HT VCB panel indoor type having followings: (a) Incoming vacuum circuit breaker of 11 KV, 630 AMP, 25 KA for 3 Sec HT conf to IEC 62271-200 with followings: (i) 630A continuous rated electrolyte copper bus bar should be insulated with full system voltage sleeve of Raychem (b) Floor trunck mounted horizontal isolation and horizontal draw out vacuum circuit breaker as per IEC 62271-200 should have three no vacuum bottles (iii) Motorised spring charging mech with integral spring charging handle for manual charging (iv) Cast resin current transformer 11 KV,200/5-5A,core 1, for metering with burden 15 VA, class 0.5 and core 2 for protection with burden 15 VA class 5P10 (v) Core regin potential transformer 11 KV/√3/110V/ √3/110V/ √3,100VA, class 3P (vi) Accessories like local remote switch and all other switches as per manufacturer. (viii) multifunction meter with RS 485 port Model No EM6400 (viii) Master trip relay
(ix) Solid state microprocessor based programmable protection relay having additional facilities: trip ckt supervision, disturbance recorder etc & sensing rated secondary current of CT (x) Panel should also have facility like: intermittent rates closing and tripping Coil, Fuel INternal arc type tested as per IEC Vacuum bottle should be epoxy encapsulated, Aux Switch wtih 6No+6NC (xi) Panel height should not exceed 2300mm (xii) Breaker and panel should be of same make-01 No Location 66 KV sub stn Ambala Additional eqpt delivered separately or mounted separately. (a) operating handle (b) Cable clamping provision © Operation installation & commissioning mannual (d) Batttry charger for motorization
Supply,installation,testing & commissioning of 11 KV out door both side extensible type with 01 No VCB floor mounted & 2 LBS outgoing with internal copper bus bars, consisting of 630 Amp fixed manual Load Break Switch . All live parts, bus bars,VCB & LBSs shall be enclosed in one tank to avoid multiple interconnections & sealed for life robotically welded non magnetic and non ferrite grade stainless steel tank Grade 304 of minimum 2.5 mm thick having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. Location: Sub stn SMB & VMB Kalpi (I) The unit shall have front cable entry for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown. it should be complete with all accessories such as Terminal boots, VPIS, cable supports, all front cable terminations, mechanical indications for Load break switch ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation up to 1000m as per IEC 60120. Extensible Bushings,if applicable shall be bolted type top mounted outside the tank for connection of external bus bar .Also, the outer enclosure shall cover the full length of the switchgear,to ensure IP3X+IP54 protection for cable boxes .
(II) The unit shall be internal arc proof 25kA for 3 sec. for tank+Cable Box ,and tested and totally safe for human beings. (III) Bidder shall provide type test report to prove compliance to the ‘Internal fault IAC-AFLR as per IEC 62271-200.Internal arc proof & testing shall be done with enclosure door in open condition, with switching devices in operation mode.(IV) 630A Load Break Switch module for making of fault current alongwith Earth Switch of full making capacity Short time withstand current - 21KA/ 3 sec Making Capacity - 52.5kAp Auxiliary contacts - 1NO + 1NC Power frequency withstand voltage - 38kV Impulse withstand voltage - 95kV Nominal operating gas pressure - 1.4 Bar abs. Front cover mechanism - IP2X Cable covers - 3X Snap action mechanism for manual operation Cable box for front termination of the cable suitable upto 3 core 185 Sqmm, 11 KV XLPE cable Right angle non-touch proof Termination boots - 1 Set (R,Y,B)
(vi) Manual operated 630 A Vacuum circuit breaker having spring stored mechanism. Three position disconnector/earthing switch downstream vacuum circuit-breaker. Three position single spring mechanism for disconnector/earthing switch “Live Cable” LED Indicators thru Capacitor Voltage Dividers mounted on the bushings. Short time breaking current - 25kA for 3 sec Making Capacity - 52.5 kAp Auxiliary contacts - 1NO + 1NC Power frequency withstand voltage - 38KV Impulse withstand voltage - 98KV Nominal operating gas pressure - 1.4 Bar abs. Front cover mechanism - IP2X Cable covers - 3X Green(ON)/Red(OFF) push buttons to operate VCB. 3O/C + 1E/F self powered solid state microprocessor based programmable protection relay with Low and High set for Over current and Earth Fault. Resin cast ring core protection CT plate mounted type : 100/5-5A core 1 for mounting with burden 15 VA, class 0.5 and core 2 for protection with burden 15 VA, class 5 P 10 A, 5P10, 2.5 VA - 3 Nos Mechanical ON/OFF/EARTH/Spring charge Indication of
Supply,installation,testing & commissioning of 11 KV out door both side extensible floor mounted 1 LBS with internal copper bus bars, consisting of 630 Amp fixed manual Load Break Switch . All live parts, bus bars, LBS shall be enclosed in one tank to avoid multiple interconnections & sealed for life robotically welded non magnetic and non ferrite grade stainless steel tank Grade 304 of minimum 2.5 mm thick having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. Location:VMB Kalpi-01 , WSB--01, FU B-01, FU A-01(Ambala) (I) The unit shall have front cable entry for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown. it should be complete with all accessories such as Terminal boots, VPIS, cable supports, all front cable terminations, mechanical indications for Load break switch ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation up to 1000m as per IEC 60120. Extensible Bushings, shall be bolted type top mounted outside the tank for connection of external bus bar .Also, the outer enclosure shall cover the full length of the switchgear,to ensure IP3X+IP54 protection for cable boxes
(II) The unit shall be internal arc proof 25kA for 3 sec. for tank+Cable Box ,and tested and totally safe for human beings. (III) Bidder shall provide type test report to prove compliance to the ‘Internal fault IAC-AFLR as per IEC 62271-200.Internal arc proof & testing shall be done with enclosure door in open condition, with switching devices in operation mode. The unit shall include the following with all necessary standard fitting required at site. (IV) 630A Load Break Switch module for making of fault current alongwith Earth Switch of full making capacity Short time withstand current - 25 kA/3 sec Making Capacity - 52.5kAp Auxiliary contacts - 1NO + 1NC Power frequency withstand voltage - 38kV Impulse withstand voltage - 95kV Nominal operating gas pressure - 1.4 Bar abs. Front cover mechanism - IP2X Cable covers - 3X Snap action mechanism for manual operation Cable box for front termination of the cable suitable upto 3 core 185 Sqmm, 11 KV XLPE cable Right angle non-touch proof Termination boots - 1 Set (R,Y,B)
Supply,installation,testing & commissioning of 11 KV out door type extensible floor mounted 1 Nos in coming V.C.B & 3 LBS with internal copper bus bars, consisting of 630 Amp fixed manual Load Break Switch . All live parts, bus bars, LBSs connections of RMU shall be enclosed in one tank to avoid multiple interconnections & sealed for life robotically welded non magnetic and non ferrite grade stainless steel tank Grade 304 of minimum 2.5 mm thick having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. Location 3 D CAR (I) The unit shall have front cable entry for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown. RMU should be complete with all accessories such as Terminal boots, VPIS, cable supports, all front cable terminations, mechanical indications for Load break switch ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation up to 1000m as per IEC 60120. Extensible Bushings,if applicable shall be bolted type top mounted outside the tank for connection of external bus bar .Also, the outer enclosure shall cover the full length of the switchgear,to ensure IP3X+IP54 protection for cable boxes .
(II) The unit shall be internal arc proof 25 kA for 3 sec. for tank+Cable Box ,and tested and totally safe for human beings. (III) Bidder shall provide type test report to prove compliance to the ‘Internal fault IAC-AFLR as per IEC 62271-200.Internal arc proof & testing shall be done with enclosure door in open condition, with switching devices in operation mode. The unit shall include the following with all necessary standard fitting required at site. (IV) 630A Load Break Switch module for making of fault current alongwith Earth Switch of full making capacity Short time withstand current - 25 kA for 3 sec Making Capacity - 52.5kAp Auxiliary contacts - 1NO + 1NC Power frequency withstand voltage - 38kV Impulse withstand voltage - 95kV Nominal operating gas pressure - 1.4 Bar abs. Front cover mechanism - IP2X Cable covers - 3X Snap action mechanism for manual operation Cable box for front termination of the cable suitable upto 3 core 185 Sqmm, 11 KV XLPE cable Right angle non-touch proof Termination boots - 1 Set (R,Y,B)
(vi) Manual operated 630 A Vacuum circuit breaker having spring stored mechanism. Three position disconnector/earthing switch downstream vacuum circuit-breaker. Three position single spring mechanism for disconnector/earthing switch “Live Cable” LED Indicators thru Capacitor Voltage Dividers mounted on the bushings. Short time breaking current - 21KA/ 3 sec Making Capacity - 52.5 kAp Auxiliary contacts - 1NO + 1NC Power frequency withstand voltage - 38KV Impulse withstand voltage - 98KV Nominal operating gas pressure - 1.4 Bar abs. Front cover mechanism - IP2X Cable covers - 3X Green(ON)/Red(OFF) push buttons to operate VCB. 3O/C + 1E/F self powered solid state microprocessor based programmable protection relay with Low and High set for Over current and Earth Fault. Resin cast ring core protection CT plate mounted type : 25/5-5A core 1 for mounting with burden 15 VA, class 0.5 and core 2 for protection with burden 15 VA, class 5 P 10 A, 5P10, 2.5 VA - 3 Nos Mechanical ON/OFF/EARTH/Spring charge Indication of Core regin potential transformer 11 KV/√3/110V/ √3/110V/ √3,100VA,class 3P
Supply, install, testing & commissioning of servo voltage stabilizer conforming to BIS 9815 -Part-1 for automatic operation, 3 phase naturally oil cooled, unbalanced type , copper wound , indoor type and designed for input variation between 360 V to 480 Volt with out put voltage stabilized at 415 V + 1% and speed of correction not more than 8 volt per second, efficiency not less than 95% capacity 1000 KVA complete all as per IS 9815 (Part I): 1994 or other relevant IS and as directed by Engineer-in-charge (Note) a. the rate inclusive for supplying stabilizer with standard fitting with protection like over load, short circuit, high/loss voltage cut off manual bypass system , IC base control circuit and installing complete including all jointing material , connecting with electrical system, earthing testing and commissioning . (b) Factory testing of acceptance test of the Voltage stabilizer shall be carried out in factory premises of OEM in presence of rep of AO prior to dispatch, information for which shall be given by the contractor to the deptt at least one month advance. (c) The contractor shall submit type test report of similar capacity or next higher capacity Servo voltage stabilize of any voltage range as per BIS clause 5.1 of 9815:1994 along with drg for Approval of Accepting officer before procurement.
Supply, install, testing & commissioning of static servo voltage stabilizer for automatic IGBT ( Insulated Gate Bipolar transistor) controlled micro processor based digital for automatic operation, 3 phase naturally air cooled, unbalanced type , copper wound , indoor type and designed for input variation between 360 V to 480 Volt with out put voltage stabilized at 415 V + 1% efficiency not less than 95% , capacity 200 KVA complete all as per IS 9815 (Part I): 1994 or other relevant IS and as directed by Engineer-in-charge with followings :- (i) Wave from distortion: Nil (ii) Response time not to exceed 10 milliseconds. (iii) Duty Cycle: Continuous 100% loading at lowest input voltage for indefinite time (iv) Rate of correction: Greater than 3000 volts/sec, the said voltage regulator should sense as well as correct any voltage sag/ fluctuation within 20 milisecons, i.e. one wave from. (v) Overload capacity: 125%, it should be able to take startup load with high in rush currents. (vi) Protections: (a) MCCB/MCB for overload and short circuit protection as per manufacturer recommendations. (b) Intelligent bypass & manual bypass arrangement.
(vii) Voltage regulations shall be performed by IGBT driven PWM invertor operating at around 20 KHZ switiching frequency with typical voltage correction time of 20 ms (one cycle for 50 Hz supply) so that output voltage complies with the requirements of ITIC curve for regulated voltage supply to electronic machinery. (viii) Voltage regulation should be achieved by superimposition of PWM wave on incoming wave, without any brake in the power path. (Note) : - (a) the rate inclusive for supplying stabilizer with standard fitting with protection like over load, short circuit, high/low voltage cut off manual bypass system , IC base control circuit and installing complete including all jointing material , connecting with electrical system, earthing testing and commissioning . (b) Factory testing of acceptance test of the Voltage stabilizer shall be carried out in factory premises of OEM in presence of rep of AO prior to dispatch, information for which shall be given by the contractor to the deptt at least one month advance. (c) The IGBT module of made in China shall not be acceptable. The contractor shall submit make & origin of country at the time of approval of drg of voltage stabiliser.
Supply install testing & commissioning of static servo voltage stabilizer for automatic IGBT ( Insulated Gate Bipolar transistor) controlled micro processor based digital for automatic operation, 3 phase naturally air cooled, unbalanced type , copper wound , indoor type and designed for input variation between 360 V to 480 Volt with out put voltage stabilized at 415 V + 1% efficiency not less than 95% , capacity 75 KVA complete all as per IS 9815 (Part I): 1994 or other relevant IS and as directed by Engineer-in-charge with followings :- (i) Wave from distortion: Nil (ii) Response time not to exceed 10 milliseconds. (iii) Duty Cycle: Continuous 100% loading at lowest input voltage for indefinite time (iv) Rate of correction: Greater than 3000 volts/sec, the said voltage regulator should sense as well as correct any voltage sag/ fluctuation within 20 milisecons, i.e. one wave from. (v) Overload capacity: 125%, it should be able to take startup load with high in rush currents. (vi) Protections: (a) MCCB/MCB for overload and short circuit protection as per manufacture recommendations. (b) Intelligent bypass & manual bypass arrangement.
(vii) Voltage regulations shall be performed by IGBT driven PWM invertor operating at around 20 KHZ switiching frequency with typical voltage correction time of 20 ms (one cycle for 50 Hz supply) so that output voltage complies with the requirements of ITIC curve for regulated voltage supply to electronic machinery. (viii) Voltage regulation should be achieved by superimposition of PWM wave on incoming wave, without any brake in the power path. (Note) : (a) the rate inclusive for supplying stabilizer with standard fitting with protection like over load, short circuit, high/low voltage cut off manual bypass system , IC base control circuit and installing complete including all jointing material , connecting with electrical system, earthing testing and commissioning . (b) Factory testing of acceptance test of the Voltage stabilizer shall be carried out in factory premises of OEM in presence of rep of AO prior to dispatch, information for which shall be given by the contractor to the deptt at least one month advance. (c) The IGBT module of made in China shall not be acceptable. The contractor shall submit make & design of country at the time of approval of drg of voltage stabiliser.
Supply and fix 250 W LED flood light with high power discrete LED housing and integral driver with IP 65 protection class, (i) CRI>70 (ii) PF >0.9 (iii) lumens min 120 lux/watt with all accessory prewired including connecting with twin core twisted flexible copperconductor cable with suitable size as required to fix on steel pole complete all as specified and as required.
Supply and fix LED street light fitting 100 watts 230 V, 50 Hz suitable for operation over voltage range of 140 volt to 270 volt duly housed in pressure die cast aluminium housing compressing of LED with individual optical lens, electronic driver with IP 66 protection including connecting lead of 3 core 1.5 Sqmm flexible copper wire from junction box to fitting complete all as specified and as directed.
Supply and fix LED post top latern 25 W input voltage 230 volt 50 Hz with die cast aluminium spigot & prismatic diffuser, IP 66 protection class including fixing arrangement like suitable clamps nut bolts and washers and connecting up with suitable size of copper conductor cable complete all as specified and as directed.
Supply and fixing 3 core PVC insulated and PVC sheathed copper conductor cable 1100 volt grade 1.5 Sqmm along the pole drawn in and including PVC conduit 20 mm dia complete with saddles/clamps as required complete all as specified and as directed
Make bore to road/cement path/hard standing for providing GI pipe 50mm both end socketed for passing armoured cable incl making good the disturbed surface complete all as specified.
Supply, testing, installation, commissioning of APFC panel of capacity 400 KVAR, 3 phase, 4 pole, 415 Volts indoor type mea out of 2mm thick CRCA sheet duly powder coated paint over a coat of red oxide perimeter suitable for IP 54 protection class and having the name plate of the manufacturer fixed and complete with contractor APFC relay and power factor meter, making bank connection with suitable size of copper wire angle iron 50x50x6mm frame and including PCC foundation with 1:2:4 type CI with 20mm graded stone aggregate complete with the followings:- (i) MCCB 4 pole 400 Amps, 35 KA with thermal adjustable -01 No. (ii) Heavy duty shunt capacitor – 50 KVAR – 06 Nos, 20 KVAR-03 Nos, 10 KVAR-02 Nos, 5 KVAR- 02 No, 2 KVAR-02 Nos, 1 KVAR-01 No (iii) Capacitor duty contactor of suitable capacity for capacitor. (iv) 4 Pole aluminium bus bar of rating 630 Amps with PVC coloured heat shrinkable sleeves. (v) Digital power factor meter- 01 No. (vi) APFC relay of suitable step. (vii) Outgoing MCCB/MCB of suitable size for capacitors. (viii) Indicator Lamp – 01 set. (ix) LED indicator for each type of bank Note :- Drg shall be got approved from AO befor procurement.
Supply and fixing thermoplastic cable junction box with 02 Nos PVC gland weather proof IP 65/66 protection class for outdoor installation with knock outs for cable entry of size 250x200x150mm hinged type with 04 Nos aluminium bus bar of sixe 25x4 mm and 08 Nos terminals with all required nuts bolts mounted on bus bar and connecting up with existing cable and duly fixed with MS clamps made out of Flat 40x3 mm thick with nuts & bolts as required complete all as specified and as directed.
M&L for maint free Chemical earthing system consisting of earth electrode 17.2 mm dia and 3 mtr long made of high tensil low carbon steel circular rod having 250 micron molecularly bonded copper on outer surface of earth electrode to be lowered in 150 mm dia bore including filling of back compound in 150 mm dia bore in immediate contact around the earth electrode and the rest of the bore shall be fitted with well compound earth and top of the bore shall be finished with 40 mm thick PCC 1:2:3 type B1 over 75 mm thick PCC 1:4:8 type D2 and back fill jam compound shall be covered of 30mmx30mm size complete all as specified
(A) (a) ACB 415 volt 800 Amps 4 pole 50 KA 01 sec 50 Hz supply draw out type with safety shutter electrically operated with 230 volt AC motor with manual handle, closing/ tripping coil UV voltage 230 volt AC, relay type-microprosser based with earth leakge, over current short circuit protection and auxillary contact minimum 7 No NO+NC, 3 NO+3NC extended upto panel terminal block for remote PLC inter lock - 03 Nos
M&L for fabrication, installation testing and commissioning of main LT panel suitable 3 phase 415 volt suitable outdoor type made out of 3.15 mm thick CRCA sheet with angle iron frame of size 50x50x6 mm cubical type complete with front and back operable, locking arrangement louver and air vent gasket for natural flow of air with front operation,having separate compartment for each MCCB of incoming and outgoing, including internal connectivity of accessories with copper strip of appropriate size with locking arrangement copper bus bar three phase 400 amps and half neutral, marking red yellow blue and black mounted on insulators made of high strength insulated material suitable for 1100 volt grade with IP 54 as per IS-13947 cable alley both side of the panel as per IS including powdered coated inside and outside of panel, PCC platform as per manufacturer Drg suitable for housing in and including the following accessories, grouting the panel in PCC complete for Tr 63 KVA :-
M&L for fabrication, installation testing and commissioning of main LT panel suitable 3 phase 415 volt suitable outdoor type made out of 3.15 mm thick CRCA sheet with angle iron frame of size 50x50x6 mm cubical type complete with front and back operable, locking arrangement louver and air vent gasket for natural flow of air with front operation,having separate compartment for each MCCB of incoming and outgoing, including internal connectivity of accessories with copper strip of appropriate size with locking arrangement copper bus bar three phase 800 amps and half neutral, marking red yellow blue and black mounted on insulators made of high strength insulated material suitable for 1100 volt grade with IP 54 as per IS-13947 cable alley both side of the panel as per IS including powdered coated inside and outside of panel, PCC platform as per manufacturer Drg suitable for housing in and including the following accessories, grouting the panel in PCC complete for Tr 200 KVA :-
M&L for fabrication, installation testing and commissioning of main LT panel suitable 3 phase 415 volt suitable outdoor type made out of 3.15 mm thick CRCA sheet with angle iron frame of size 50x50x6 mm cubical type complete with front and back operable, locking arrangement louver and air vent gasket for natural flow of air with front operation,having separate compartment for each MCCB of incoming and outgoing, including internal connectivity of accessories with copper strip of appropriate size with locking arrangement copper bus bar three phase 400 amps and half neutral, marking red yellow blue and black mounted on insulators made of high strength insulated material suitable for 1100 volt grade with IP 54 as per IS-13947 cable alley both side of the panel as per IS including powdered coated inside and outside of panel, PCC platform as per manufacturer Drg suitable for housing in and including the following accessories, grouting the panel in PCC complete for Pump House :-
S&F cable rout indicator made out of MS/CI including arrow indicating towards route of cable including imbossing mark HT cable complete all as specified and as directed.
M&L erection of medium grade GI pipe 40mm dia, 2.5 mtr long above Ground, for fixing of Post top lantern fitting including painting with two coat of silver colour paint and necessary excavation and earth work including foundation
ROAD HARDSTANDING AND CULVERT
M & L for Rolling and consolidation of subgrade (500 mm) using power roller 8 to 12 tonne capacity to the compaction of 98% of MDD and minimum 4% soaked CBR throughout complete all as specified and directed.
M & L for 200mm thick (compacted thickness) in two layers of 100 mm thick each GSBC (Granular Sub Base Concrete) grading I as per table 400-I MORTH specifications and mixed with 35% coarse graded crushed stone agg by providing close graded material mixing by any means as per site conditions, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory roller 8-10 tonne capacity and maintaining the required density, grading and moisture content as per MORTH specifications complete all as specified and directed
M & L for 225 mm thick (compacted thickness) WMM (Wet Mix Macadam) in three layers of 75 mm each with granite, trap or basalt stone aggregate of grading 2 (63 mm to 40 mm size) or of grading 2 (63 mm to 40 mm) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site for all leads and lifts, to be laid using mechanical paver, spread watered, rolled and consolidated to required gradient and camber with vibratory type power roller 8-10 tonne capacity to achieve the desired density complete all as specified and directed
M & L for 50 mm thick (average consolidated thickness) laying premix bituminous macadam using graded crushed stone aggregate mixed with paving bitumen of grade (VG-30) @ 4% by weight of total mix laid, rolled and compacted to required gradient and camber using 8 to 12 tonne power road roller complete all as specified and as directed.
M & L road line painting 100 mm wide with golden yellow, white thermostatic compound with reflectorised glass beads on bitumen road providing and laying of hot applied thermostatic compound 2.5 mm thick including reflectorised glass beads @ 250 gm per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35 including cleaning of old road marking paint, the finished surface to be levelled, uniform and free streaks and holes in addition where arrows of letters are to be provided thermostatic compound may be machine sprayed the colour of compound with traffic diversion arrangements if required as per MORT&H clause 803.4 complete all as specified and as directed
Rolling and consolidating to required level gradient or camber formation surface of road /berms in cutting using power roller exc 8 tonne and not exc 12 tonne to the stabilised compaction of sub base to achieve 98% of MDD and saturated stabilise 'K' value of minimum 4% (4.0 kg/cm²/cm) soaked CBR throughout complete all as specified and directed.
M&L for 150 mm thick GSBC (Granular sub base concrete) grading I as per table 400-1 morth specifications and mixed with 35% coarse graded crushed stone agg by providing close graded material mixing by any means as per site conditions, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory roller 8-10 tonne capacity and maintaining the required density, grading and moisture content as per MORTH specifications, compacted stabilised sub base of 98% MDD to achieve saturated stabilised 'K' Valve of min 4.0 Kg/sqcm complete all as specified and as directed
M & L for 150 mm thick WMM with coarse stone aggregate of grading as specified in double layer of 75 mm thick each using mechanical paver and rolled with vibratory type power roller 8-10 tonne capacity to required gradient and camber complete all as specified
M& L for providing 100 mm thick (compacted thickness) DLC (Dry Lean concrete), grade M-15 (Design Mix) 7 day compressive strength 10 N/ MMsq using 20 mm graded stone aggregate with min cement content of 250 kg/Cum including spreading, rolling and consolidating to required gradient and camber using mechanical paver complete all as specified and directed.
Material and labour providing 250 mm thick pavement quality concrete (PQC) of flexural stength 4.5 MPa (28 Days) Kilogram per sq.cm in field using min 400 kg of cement per cubic metre, ( with maximum size of coarse aggregate upto 40mm) as per mix design, with incorporation of non-circular synthetic fibre @ 1.00 kg/cum, including all necessary form work for laying in bays complete all as specified and as shown on drawings. Notes:- (i) construction joints, dummy joints (contraction joints) and expansion joints shall be measured and paid separately under respective items. (ii) Deduction shall be made in computing concrete quantity for expansion joints. (iii) Polyster non-circular fibre as secondary reinforcement mixed in concrete. (v) The PQC shall be laid using mechanical paver cum vibrator of requisite capacity (vi) Necessary finishing of concrete surface by brooming while the concrete is green all as specified and directed
Providing textured finish by brooming surface of concrete pavement while concrete is green all as specified and directed.
Supply only synthetics polyster micro fibres all as specified in particular specificatoin of synthetic fibers.
Material and labour for forming contraction joint (dummy joint) upto 1/3rd to 1/4th depth of concrete slab (PQC) x 8 mm wide (using diamond cutter) an filled with poly sulphide or polyurathene joints sealant compound using mechanical means to a depth of 10mm (depth min above the back up rod) with min performance gurantee of 10 years and min movement accomanadances factor (MAF) + 30 % conforming to the requirment of BS 5212 AND EN-141875-2003 for hydrolysis/water resistance test inculding two coats primer and providing 10mm dia, approved quality closed cell polythene back up rod, applying masking tape on edge of joint to prevent accidnental slipage of seleant on top surfaces and to give a neat finish to the selant and removing the masking tape after seleant is applied complete all as specified and as directed .
Material and labour for forming construction joint 10mm wide upto 25mm depth of concrete to form joint using diamond cutter ) and filled with slab filled with poly sulphide or polyurathene joints sealant compound using mechanical means to a depth of 10mm (depth min above the back up rod) with min performance gurantee of 10 years and min movement accomanadances factor (MAF) + 30 % conforming to the requirment of BS 5212 AND EN-141875-2003 for hydrolysis/water resistance test inculding two coats primer and providing 12mm dia, approved quality closed cell polythene back up rod, applying masking tape on edge of joint to prevent accidnental slipage of seleant on top surfaces and to give a neat finish to the seleant and removing the masking tape after seleant is applied complete all as specifed and as directed.
Providing and laying expansion joint 25mm thick full depth of concrete using expanded polythylene form expansion joint filler pad in sheet form of brand 'Supreme capcell HD 100" or equivalent as approved by the GE and 30mm dia non cross linked Expanded polyethylene armour rod as per manufactures specifications. Density of expansion pad shall be 100 Kg/cum ± 10% and density of 30mm dia armour rod shall be 24 to 26 Kg/cum and filled with 10mm deep polysulphide (pour grade) RDL 941 EH, including painting of sides with polyethyelene primer applied in two coats with brushes on the sides of joint at an interval of 30 minutes, armour rods of approved quality fixed with suitable arrangements complete as per directions of Engineer-in-charge. Polythylene shall be confirm to BS 5212-1990 and primer shall be graded RDL-942 of Cholsey or equivalent as approved by the GE.
M&L Painting lines , dashes, arrows, letters etc. on pavement , roads and the like exceeding 10 cm width with aqua based road marking paints in two coats over a coat of primer including preparation of surfaces etc complete all as specifed and as directed.
M&L for soil stabilisation by mixing with cement upto 6 to 12 % of cement by weight of dry soil to improve the subgrade modulus (K Value) to 4 Kg/cm2/cm and compacted to 98% of MDD. Mix to be done with mechanical means, spread and compacted with power vibrating roller to achieve 'K' Value of 4 % and CBR Value of 98% of MDD, using all mechanical equipments complete all as specified and as directed.
EXTERNAL WATER SUPPLY
Drilling trial bore hole by direct or reverse rotry combination rig plant and equipment through any kind of soil/rock strata by drilling not less than 250mm bore hole upto 350 mtr depth below ground level with and including disposal of retrieved/surplus soil to a distance not exceeding 500 mtr complete all as specified & as directed.( Note: sample of strata shall be collected at 3 mtr interval/depth and shall be kept in strata box as a recored.)
Expanding trial bore direct or reverse rotry combination rig plant and equipment through any kind of soil/rock strata by drilling not less than 680mm bore hole upto 120 mtr for 350 mm casing pipe from ground level with and including disposal of surplus soil to a distance not exceeding 500 mtr complete all as specified & as directed.
Supplying, lowering and fixing into bore hole 350mm bore dia MS housing pipe ERW, 8mm wall thickness in six metre length having threading and welding at both ends externally complete all as specified and as directed.
Supplying, lowering and fixing into bore hole 250mm bore dia MS casing pipe ERW, 8 mm wall thickness in six metre length having threading and welding at both ends externally complete all as specified and as directed.
Supplying, lowering and fixing into bore hole 250mm dia stainless steel slotted pipe of grade SS 304 , 8 mm wall thickness having longitudinal slotes of 1 mm width cut into the pipe including fixing/jointing to the casing pipe by threading and welding as per the strata and ground requirements complete all as specified and as directed.
Supplying, fixing and lowering of centering guide into bore well made out of flat rings, ribs suitable for 350/250 mm nominal bore MS casing pipe complete all as specifcied and as directed.
Supply & fixing mild steel socket of size 350mm heavy duty for connecting casing pipe with proper welding complete all as specified and as directed
Supply & fixing mild steel socket of size 250mm for connecting casing pipe with proper welding complete all as specified and as directed
Supply and fixing Mild steel reducer of size 350x250mm (nominal bore) having wall thickness 8mm, screwed at both ends with & including necessary fittings and jointing with jointing material complete all as specifcied and as directed.
Supply and fixing bore well cap suitable for 350mm nominal bore casing pipe made out of MS sheert 4.0 mm thick in two half duply drilled/hole two nos each side including nut, bolt and washer etc complete all as specifcied and as directed.
Supply and fixing holding clamp of 2.5 Mtr long made out of MS plate 16 mm thick suitable suitable casing pipe 350 mm bore and GI pipe 80 mm bore including necessary nuts,bolts and twin washers at groung level embeded in PCC block complete all as specified & as directed . Note :- PCC block and GI pipe shall be measured and paid seperetely.
Supply and fixing 80 mm bore GI pipe , heavy duty for watering with cap complete all as specified & as directed .
Material and labour for PCC 1:2:4 type B1 using 20 mm graded mechanically crushed stone aggregates finished even and smooth without using extra cement for embedding clamps complete all as specified & as directed .
Supplying, pouring and packing pea gravel of size 3 to 6 mm size duly screened and washed around casing pipe and slotted pipes complete all as specified and as directed. Note: - For the purpose of measurement, gravel brought by the contractor shall be stacked properly at site and measurement shall be taken in measurement box to arrive at the net quantity of gravel used.
Development of tube well bore by compressor of capacity not less than 100 Cum/hr and 600 PSI till clear water is obtained including stabilization of the tube well and carrying out yield test indicating static water level, draw down complete all as specified and as directed.
Development of tube well bore by heavy duty submersible pump set of capacity not less than 20000 GPH so as obtain sand/silt free water complete all as specified and as directed. Note :- Test record for the same duly signed by the Engr-in-Charge & contractor shall be kept on record .
Supplying and fixing drawing of assembly lowered alongwith bore well details on full scape size paper duly laminated and framed on and including 10mm thick commercial type veneered particle board complete all as specified and as directed.
Testing of water sample for potability by chemical analysis as well as bacteriological potability from Govt Laboratory and submission of the report complete all as specifcied and as directed.
Electronic logging by means of electric logger for the total depth of tube well submission of 4 copies of logging sheet alongwith one original copy and its interpreation complete all as specified and as directed
Supplying and lowering in bore hole ERW column pipe 80mm dia, heavy grade in approximately 3 mtr length each duly flanged at both ends by welding with special provision such as slots for housing two Nos submersible cable of size 16 Sqmm and holes for fixing nuts & bolts with and including rubber flange and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Supplying, fixing and jointing Cast iron sluice valve, ISI marked, Class PN-1 with flanged and drilled ends, suitable for 80mm nominal bore pipe/fittings with iron wheel high tensile steel spindle with & including joints and jointing materials such as bolt, nuts, washers and rubber gasket etc including taking down of old valve as exist at site complete all as specified & as directed.
Supplying, fixing and jointing Non return valve of cast iron for 80mm bore pipe Class-I (ISI marked) with brass flap and seat without by pass engagement, flanged both ends, joints and jointing material such as nuts,bolts,washers & rubber gasket etc complete all as specified and as directed.
Material and labour for water pressure gauge, range 0-100 PSI, dial type 100mm nominal dia with and including control valve adopter etc and testing on pipe line complete all as specified and as directed
Supplying, lowering, jointing and testing PVC insulated, multistranded copper conductor 16 Sqmm (nominal area), 3 core flat submersible cable complete all as specified and as directed
Supplying, installing,commissioning and testing Granular chlorination dosing pump, high pressure, single head, gear motored adjustable dosing pump having output 0 to 5 ltrs per hour, adjustable high pressure upto 10 Kg per Sqcm with and including preperation tank, dosing tank with lid of suitable capacity consisting of water inlet line, outlet with Y strainer, drain, overflow, NRV, foot valve with strainer, conical bottom for sludge deposition, pot hole with cover, level gauge, agitalor ofsuitable capacity single phase mounted motor with plastic shaft & impeller, injector dosing pump, inlet arrangements, drain, overflow level gauge , inspection port all as per manufecturer's recommendations with and including necessary electric extension cable upto socket point complete all as specified and as directed.
M&L for Construction of valves pit chamber of internal size 900mmx1200mmx900mm with one brick thick brick masonary wall in cement mortor(1:4),PCC foundation 10cm thick (1:4:8) type D2 with rendering 15 mm thick internally and top surface ,MS frame of angle iron 50x50x4mm and 3mm thick MS sheet cover with locking arrangement, hold fast, hinges including painting to steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer and necessory excavation and earth work including dismantling of existing complete all as specified and directed.
S&F Punched tape razer blade concertina coil of 600 mm coil dia including provision of mild steel (annealed) binding wire complete all as specified and as directed.
M&L for Construction of valves pit chamber of internal size 600mmx600mmx450mm with one brick thick brick masonary wall in cement mortor(1:4),PCC foundation 10cm thick (1:4:8) type D2 with rendering 15 mm thick internally and top surface ,MS frame of angle iron 50x50x4mm and 3mm thick MS sheet cover with locking arrangement, hold fast, hinges including painting to steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer and necessory excavation and earth work including dismantling of existing complete all as specified and directed.
S&F reflex valve 50m dia with all fixing accessories complete all as specified and as directed.
DG SET
Supply, installation and testing of silent Diesel Engine driven generating set Capacity 1010 KVA/808 KW 3 phase 415 volt CPCB II compliant prime rated DG, radiator cooled powered by full authority electronic CRDI mpower engine coupled with 1010 KVA alternator microprocessor based controller silencer, antivibration mounting, exhaust flexible connector, battery with cable fuel tank acoustic enclosure with the following description:- DIESEL ENGINE: 4 stroke cycles, liquid cooled developing appropriate BHP @ 1500 rpm as per BS: 5514/ISO 3046. Engine shall be provided with electrical starting system, fuel system, lube oil system combustion air system and cooling system. ALTERNATOR: Synchronous alternator of 1010 KVA suitable for operation at 1500 RPM generating 415 Volt at 0.8 PF , 50 Hz 3 phase and 4 wire system, brushless type, separately excited & self regulated through an AVR. Alternator shall be suitable for tropical climate and generally confirm to BS: 2613/IS: 4722.Alternator should have Max +- 1% voltage regulation static conditions, IP 23 proteation with H class insulation,permissible overload of 10% for one hour in 12 hour of operation and AREP excitation system and standard AMF controller complete with all standard accessories all as per manufacturer recommended
Supply, installation and testing of silent Diesel Engine driven generating set Capacity 250 KVA/200 KW 3 phase 415 volt CPCB II compliant prime rated DG, radiator cooled engine coupled with 250 KVA alternator microprocessor based controller silencer, antivibration mounting, exhaust flexible connector, battery with cable fuel tank acoustic enclosure with the following description:- DIESEL ENGINE: 4 stroke cycles, liquid cooled developing min 310 BHP @ 1500 rpm as per BS: 5514/ISO 3046. Engine shall be provided with electrical starting system, fuel system, lube oil system combustion air system and cooling system. ALTERNATOR: Synchronous alternator of 250 KVA suitable for operation at 1500 RPM generating 415 Volt at 0.8 PF , 50 Hz 3 phase and 4 wire system, brushless type, separately excited & self regulated through an AVR. Alternator shall be suitable for tropical climate and generally confirm to BS: 2613/IS: 4722.Alternator should have Max +- 1% voltage regulation static conditions, IP 23 proteation with H class insulation,permissible overload of 10% for one hour in 12 hour of operation and AREP excitation system and standard AMF controller complete with all standard accessories all as per manufacturer recommended
Supply, installation and testing of silent Diesel Engine driven generating set Capacity 62.5 KVA/50 KW 3 phase 415 volt CPCB II compliant prime rated DG, radiator cooled engine coupled with 62.5 KVA alternator microprocessor based controller silencer, antivibration mounting, exhaust flexible connector, battery with cable fuel tank acoustic enclosure with the following description:- DIESEL ENGINE: 4 stroke cycles, liquid cooled developing min 90 BHP @ 1500 rpm as per BS: 5514/ISO 3046. Engine shall be provided with electrical starting system, fuel system, lube oil system combustion air system and cooling system. ALTERNATOR: Synchronous alternator of 62.5 KVA suitable for operation at 1500 RPM generating 415 Volt at 0.8 PF , 50 Hz 3 phase and 4 wire system, brushless type, separately excited & self regulated through an AVR. Alternator shall be suitable for tropical climate and generally confirm to BS: 2613/IS: 4722.Alternator should have Max +- 1% voltage regulation static conditions, IP 23 proteation with H class insulation,permissible overload of 10% for one hour in 12 hour of operation and AREP excitation system and standard AMF controller complete with all standard accessories all as per manufacturer recommended
Supply and insulation of high galvanized mast light 12.5 Mtr long with and including 04 Nos 120 Watt LED flood light symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 5 mm dia 97/19 gauge and double drum winch with luminaire mounting arms, pully assemble, aviation obstruction light, suitable FP lightening arrester spike including RCC foundation as per recommendation of manufacturer all as specified and as directed
PRIME COST SUM Supply and install testing and commissioning multi stage submersible pump set alongwith bronze impeller, directly coupled with motor, suitable for 250 mm bore well operated on AC 3 phase, voltage range 440V, 50 Hz and control panel outdoor type complete. The motor casing shall be of stainless steel, pump shaft/ motor shaft shall be of stainless steel, pump bowls shall be of high graded cast iron all as specified and directed. The pump and motor shall comply to all the requirements of relevant IS and Submerssible cable 3 core multi stranded copper conductor PVC insulated, water proof, ISI marked of suitable size for connecting bore well submerssible pump sets. Note: i) The tenderer are required to work out and quote their rates for item of works in the manner set out in condition 5 of IAFW-2249 and quote their rates per unit in “figures” and percentages derived by the software, the amount quoted by tenderer in figures shall not exceed the percentage of 15%(Plus). In the event of percentage quoted by contractor exceeds 15%(Plus) the percentage amended to 15% over the amount inserted by department and figures amount shall be amended accordingly.
A K BANSAL AND CO
J.D.Builders
United Sales Corporation
Onkar Nath Bhalla And Sons Contractor Pvt. Ltd.
M/s Khanna Enterprises
Bidder Name
A K BANSAL AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid