Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC JOGESHWARI W 758 ADARS NEW LINK ROAD 758 ADARS MUMBAI 400101 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400101 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹7.8 L+₹1.4 L (21.5%)Rejected-Finance GANDHI CHOWK LANSDOWNE DISTT PAURI GARHWAL 246155 | LANSDOWNE | PAURI GARHWAL | UTTARAKHAND | 246155 | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹9.2 L+₹2.8 L (44.6%)Rejected-Finance 289 KASERU KHERA MAWANA ROAD MEERUT 250001 U P | MEERUT | UTTAR PRADESH | 250001 | L3 | Rejected-Finance BEING LOWEST |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
2 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I Lansdowne
Asst Garrison Engineer (I) Lansdowne, Disst- Pauri Garhwal Pin-246155
REPAIR TO MAINTENANCE OF LIGHTING PROTECTION SYSTEM AT VARIOUS LOCATION UNDER AGE I LANSDOWNE
2022_MES_536249_1
8756/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I Lansdowne
Class E Cat b i
6 documents required · 6 mandatory
₹500
AGE I Lansdowne
₹19,000
24 Aug 2022
7 Jul 2022
4 Aug 2022
7 Jul 2022
2 Aug 2022
21 Jul 2022
60 days
Amount
Supply and fixing in replacement of Air termination single pointed aluminium rod 12mm dia and 300mm long including taking out the existing one complete all as specified and directed a
S&F in replacement of Brass Copper lightning Arrestor 9.2mm diameter and 915mm length with 5 spikes and base plate 8.5x8.5 cm for Bldg protection including taking out the existing one complete all as specified and directed.
All as per serl Item No 01 here in before but Fixing only of Air Termination rod 12mm dia and 300mm long complete etc retrieved for reuse complete or all as directed and Specified.
Supply and fixing in replacement of test terminal block made of gun metal or phosporus bronze size 75x75x25 mm drilled and screwed including 03 Nos, 8mm dia 25 mm long hex, head scew including taking out existing unsv test terminal blocks complete all as specified and direted.
All as per serl Item No 04 here in above but Fixing only test terminal block made of gun metal of any size complete etc retrieved for reuse complete or all as directed and Specified by Engr-in-Charge.
Supply and fixing in replacement aluminum strip 25x3.15mm with saddles and fixing screws with rubber washers for protection of water leakage etc for roof conductors and down conductors above ground including taking out existing aluminium strip complete all as specified and directed
All as per serial Item No 06 here in above but Refixing only Aluminium strip including realiging of strip and refixing of PVC/Porcelain insulators with 6cm long screws etc for roof conductors and down conductors retrieved ground complete all as speciifed and directed.
Supply and fixing in repair/replacement of Galvanized iron strip 32x 6mm burried in ground/on surface/on wall including taking out the existing one complete all as specified and directed.
All as per ser Item No 08 here in above but Fixing only Galvanized iron strip 32x 6mm complete etc retrieved agaist e for reuse complete or all as directed and Specified.
S&F for GI tubing, 40mm bore, light grade with fittings like MS clamps, Nut & Bolts for fixing to wall or laind infloors complete all as specified and directed.
M&l PCC 1:2:4, type B1 (using 20mm stone aggregate) for install to air termination rod complete all specifed and direccted
S&F in repair/replacement of PVC Sleeve suitable for insulation of earth strip of size not more than 32mm width incl disconnecting earth strip for insertion of sleeve all as required at site or as directed by Engr-in-Charge.
S&F for Porcelain based post insulators suitable to insulated strip from wall/fllor/ceiling including drilling holes to al strip for fixing insulators and providing 2 nos rawl plugs and two rubber wahers to avoid any leakage in roof of appropriate size for sixing insulator to wall or floor or ceiling complete all as specified and directed.
M&L for UL listed, CPRI tested at 25 KA fault current for one second maintenance free, low carbon High tensile copper bonded steel earth rod of 10 feet long having diameter of 17.2mm with copper bonding thickness of 250 micron tested as per IEC 62561-2 & is provided with universal clamp made of SS to connect rod with flat conductor. Earth enchancing compund shall be of 30 Kg/pit (resistivity is 0.12 ohm meter) tested as per IEC 62561-7, by lab. The above arrngements shall be provided with heavy duty earth poly plastic cover of 6000Kg load bearing capacity.earth electrode shall be covered with not less than 30 Kgs of earth life compund .The excavaed gap shall be back filled with excavated earth and shall be properly consolidated with water. the earth pit entry is to be sealed with bitumen compound. the eath strip of size 32 x6mm from earth bus is connected to earth test point by means of nut, bolts and washers. Necessary meggar is to be done in the presence of the Engr-in -Charge , and the reading should be as per IE standards and if desired results are not obtained the earthing will be redone at no extra cost . The earthing shall comply to IS 3043 (h) Contractor has to provide manufacturer drawing and get if approved from Engr-in -Charge and AGE(I) before executing the work.
PIONEER REFRIGERATION AND ELECTRICALS
Shikha Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .