| 1 | L1₹50.0 LAccepted-AOC 17 1305 ARIAKATTU PALLURUTHY KOCHI 682 006 | KOCHI | ERNAKULAM | KERALA | 682006 | L1 | Accepted-AOC BEING LOWEST TENDERER |
Tender Value
₹50.0 L
EMD Value
₹99,000
Closing Date
10 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(NW)KOCHI
GARRISON ENGINEER (NW) MILITARY ENGINEER SERVICES NAVAL BASE POST -682 004
AS PER BOQ AND TENDER DOCUMENT
2023_MES_589352_2
8314_GE_NW
Open Tender
Civil Works
Item Rate
180 days
KOCHI
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE(NW)KOCHI
₹99,000
Yes
3 Aug 2023
18 May 2023
12 Jun 2023
18 May 2023
10 Jun 2023
24 May 2023
18 May 2023 - 29 May 2023
Amount
Taking down of existing roof treatment of any descriptions and removal of dismantled materials to a distance exc 500m and n.exc 1 Km complete all as specified and directed.
M&L Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. Brushing neat cement slurry with 3.0kg of cement per sqm complete all as specified and directed
M&L for Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed
M&L for 50 mm PCC 1: 2: 4 Type B0 using 12.5mm graded stone aggregate as in levelling course of roof with WPC as per manufacturers instructions complete all as specified and directed. Note:- WPC shall be measured and paid separately
M&L for Concrete bed of width 300mm in PCC 1:3:6 type C2 using 40mm graded stone aggregate including packing under, and haunching against the top of roof and side of parapet wall complete all as specified and directed
M&L for screed bed or bedding layer of mortar 10 mm thick on concrete/brick surfaces in CM 1: 4 finished even and smooth without using extra cement with WPC as per manufacturers instructions complete all as specified and directed Note:- WPC shall be measured and paid separately
Supply only Water Proofing Compound
M&L for applying oil based bitumen primer @ 0.20 Kg/Sqm on the prepared surface, and then apply a coat of blown type bitumen grade 85/25 heated to a working temprature of 180 degree centigrade and applied @ 1.20 Kg/sqm onthe surface area and providing & laying 4mm thick APP modified water proofing membrane weighing not less than 4 Kg/Sqm reinforced with non woven polyester matt weighing not less than 160 gm/sqm having softening point not less than 140 ̌ C, longitudinal tensile strength not less than 650 N/5cm, tearing strength of 180 N(min) with a static puncture resistance of 180 by torch application incl min 10 cm side overlap and 15 cm end laps applying a coat of blown grade hot bitumen 85/25conforming to IS 702 heated to working temperature of 140 ̌ C over the membrane 1.20 Kg/sqm finishingthe surface with solar reflective bituminous aluminium paint @ 0.10 Kg/Sqm complete all as specified and as directed by Engr-in-charge. Note:- Work has to be executed without disturbing/causing any damage to the existing solar panels.
S&F 110 mm bore PVC (SWR) rain water pipes single socketed in any length with rubber ring joints fixed to walls (jointing shall be done with solvent cement) complete all as specified and as directed .
S&F in repair PVC bend 110 mm dia complete all as specified and directed
S&F in repair PVC Brackets suitable for fixing 110 mm dia PVC pipes
Taking down chowkhats or frames n.exc 1.5 Sqm each with shutters (with out taking of shutters from the frames).
Taking down chowkhats or frames exc 1.50 sqm but not exc 4 sqm each
S&F for powder coated aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc.(minimum thickness of powder coating 50 micron), complete all as specified and directed
M&L Powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 nos.) suitable handle (1 no.) tower bolt 100mm (02 Nos) complete all as specified and directed. Note:- Minimum thickness of powder coating shall be 50 micron.
M&L Powder coated aluminium window and ventilator shutters, fixed type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable handle (1 no.) tower bolt 100mm (02 Nos) (minimum thickness of powder coating 50 micron) complete all as specified and directed. Note:- Minimum thickness of powder coating shall be 50 micron.
S&F sheet glass, ordinary quality 4mm thick and glazing with oil putty in square n exc 0.5 sq. m in each pane, complete all as specified and directed
S&F Figured glass pin head type and glazing with oil putty in squares not exc 0.5 sqm in each pane thickness in 3 mm complete all as specified and directed
M&L Powder coated aluminium sliding window and ventilator frame without sash bar including all necessary jointing cleat , hold fasts , rubber gasket, anodised snap beading, anodised aluminium fitting such as aluminium fitting such as 'F' channel if required for wire mesh or aluminium grill, aluminium handle, locking arrangement etc with following HINDALCO section catalog Nos or equivalent of other manufactureres.. 1. 4095 - 61.98x29.70x1.60 mm = 2 Track Bottom 2. 4096 - 61.98x29.70x1.60 mm = 2 Track side and top 2 .9777 - 39.00x20.00x1.60 mm = Shutter Vertical 3. 3994 - 41.00x20.00x1.20 mm = Shutter top & Bottom. 4. 9778 - 39.00x20.00x1.50xmm = Shutter Vertical Inter Lock, including provn of 4mm thick sheet glass complete all as specified and as directed
S&F Powder coated aluminium sliding window and ventilator frame without sash bar including all necessary jointing cleat , hold fasts , rubber gasket, anodised snap beading, anodised aluminium fitting such as aluminium fitting such as 'F' channel if required for wire mesh or aluminium grill, aluminium handle, locking arrangement etc with following HINDALCO catalog No. or equivalent.of other manufactureres. 1. 4087 - 92.36x29.70x1.20 mm = 3 Track Bottom 2. 4099 - 92.36x29.70x1.20 mm = 3 Track Side and Top 3. 9395 - 39.00x20.00x1.10 mm = Shutter Vertical 4. 3994 - 41.00x20.00x1.20 mm = Shutter top & Bottom. 5. 9779 - 39.00x20.00x1.16xmm = Shutter Vertical Inter Lock, including provn of4mm thick sheet glass and stainless steel ,wire mesh 0.36mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and directed
S&F aluminium powder coated dark coloured deco grill 75 mm aperture, made out of 7.5 mm plate and finished decogrillfe will have 7.5 mm width and 6 mm thick with rubber beading & looks etc complete all as specified and directed.
M&L for rendering 8mm thick cement plaster in CM 1:4 finished even and smooth without using extra cement over 12mm thick back coat on brick or concret wall surfaces with cement mortar (1:6) complete all as specified and directed
M&L for rendering 10 mm thick on surfaces other than fair face of brick work in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed
M&L for preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over and including two coats of wall putty over one coat of alkali resistant primer complete all as specified and directed. Note:- The work shall be carried out all as per manufactureres instruction.
M&L for preparation of newly plastered wall surfaces and applying two coats of antifungal exterior emulsion paint over a coat of alkali resistant primer complete all as specified and directed. Note:- Application of paint and primer shall be as per manufacturer's instruction.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed .
Taking down cement plastered on Brick/Concrete wall and ceiling including racking out joints, hacking for key, scrubbing down with watercomplete all as specified and directed
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for Pre-cast cement concrete block masonry with solid blocks 1:3:6 type C1, (20 mm graded stone aggregate), exc. 10 cm in width and setting in 1:6 cement mortar, complete all as specified and directed
M&L for cement plaster in two coat 8 mm thick in cement mortar 1:4 using WPC over 12mm in cm 1:6 on external surfaces finished even & smooth without using extra cement complete all as specified and directed. (Note:- WPC shall be measured and paid seperately)
M&L for preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over one coat of alkali resistant primer complete all as specified and directed. Note:- The work shall be carried out all as per manufactureres instruction.
Dismantling structural steel work including doors, gates but excluding framed truss etc
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation and getting out in soft/ loose soil.
Removing excavated soil to a distance exc.250m but n.exc 500m and depositing where directed by Engr-in -charge.
Returning filling in soft/loose soil including spreading levelling watering and wall ramming in layers n/exc 25 cm thick all as specified and directed
M&L Plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation complete all as specified and directed
M&L for cement concrete 1:2:4 type C1 using 20 mm graded stone aggregate as in coping including use and waste of formwork etc complete all as specified and directed
M&L 10mm thick rendering in cement mortar (1:4) on fair faces of concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
S&F Concertina coil 7.15mm outer dia in closed condition and stretch to 700mm dia 8mm long with core wire dia 2.59mm, galvanised with 240 gm/sqm of zinc coating, the weight of each shall not be less than 8.57 kg/Metre (plus or minus 5%) and shall contain 50 turns with fixing clips including taking down of old concertina coil and complete all as specified as directed by Engr-in-Charge.
S&F in repair Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)
Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and as directed.
M & L for Preparation of new steel surface of any description exc 10cm width or girth and applying 2 coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S&F 180mm bore PVC (SWR) rain water pipes singles socked in any length with rubber rings fixed to walls (jointing shall be with solvent cement) complete all as specified and as directed.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .