| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.0 LAccepted-AOC 13 THAKKAR PLOT DEEPAK KUNJ PORBANDAR 360575 | PORBANDAR | GUJARAT | 360575 | ₹45.0 L Quoted ₹46.4 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹50.7 LRejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | ₹50.7 L | L2 | Rejected-Finance BEING L2 |
| 3 | L3₹54.2 LRejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹54.2 L | L3 | Rejected-Finance BEING L3 |
| 4 | Rejected-Technical PLOT NO P PARASNAGAR NR SBI BANK NARSANG TEKRI PORBANDAR 360 575 | PORBANDAR | GUJARAT | 360575 | - | - | Rejected-Technical NOT RECOMMENDED DUE TO FIRM NOT ENLISTED WITH REQUIRED APPROPRIATE CATEGORY b(ii) AS PER NIT |
| 5 | Rejected-Technical C O BHAGYODAY STORES BAZAR CHOWK NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | - | - | Rejected-Technical NOT RECOMMENDED DUE TO FIRM NOT ENLISTED WITH REQUIRED APPROPRIATE CATEGORY b(ii) AS PER NIT |
| Sl No | Description | Qty | Unit | JAMNAGAR ELECTRIC AND MACHINERY CO L3 | OM ENGINEERING L1 | SURESH ELECTRICALS L2 |
|---|---|---|---|---|---|---|
| 0.00Schedule 'A' | ||||||
| 1.00 | Taking down carefully burnt out aluminium/copper point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, fluorescent tube light fittings etc., to be measured and paid for separately) removing materials to store for schedule of credit and making good to the disturbed surfaces of walls ceilings and floors etc., complete all as specified and directed by Engineer-in-Charge. | 103 | Per Point | 35 ₹3,605 | 19 ₹1,957 | 25 ₹2,575 |
| 2.00 | Disconnecting of unserviceable sub main wiring of any size and including steel conduit and accessories & removing from site and making good the disturbed surfaces including painting, complete all as specified and directed by Engineer-in-Charge. | 120 | Running Metre | 55 ₹6,600 | 19 ₹2,280 | 30 ₹3,600 |
| 3.00Material & Labour for point wiring using ISI marked 1.1 kV grade single core FR-LSH flexible cable, conforming to IS: 694-1990, having multi-drawn thin strands of electrolytic copper conductors in existing conduit/ Provision of PVC casing capping as per site requirement size conforming to IS: 8130- 1984 and insulation conforming to IS: 5831- 1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm size PVC medium grade surface/recessed casing capping, modular cover-plates and frame complete all as specified in IS: 732- 1989, complete all as specified and directed by Engineer-in-Charge. NOTE: Circuit wire from DB to switch boards shall be included in quoted rate. Note (i) Existing Modular sheet metal box should not be removed (ii) Mounting plate and cover plate of existing size is to be replace and rate are deemed to be included in quoted rate. (iii) PVC casing capping measured and paid under relevant Item. | ||||||
| 3.01 | One light /fan/exhaust point controlled by one, one way switch | 40 | Per Point | 890 ₹35,600 | 816 ₹32,640 | 888 ₹35,520 |
| 3.02 | One light point controlled by 2, Two way switch | 2 | Per Point | 990 ₹1,980 | 816 ₹1,632 | 950 ₹1,900 |
| 3.03 | One 5 pin socket outlet 5/6 amps on the same board. | 20 | Per Point | 390 ₹7,800 | 240 ₹4,800 | 200 ₹4,000 |
| 3.04 | One 5 pin socket outlet 5/6 amps on independent board. | 25 | Per Point | 890 ₹22,250 | 816 ₹20,400 | 888 ₹22,200 |
| 3.05 | One bell point controlled by one, one way switch | 2 | Per Point | 990 ₹1,980 | 816 ₹1,632 | 950 ₹1,900 |
| 4.00Material & Labour for point wiring using ISI marked 1.1 kV grade single core FR-LSH flexible cable, conforming to IS: 694- 1990, having multi drawn thin strands of electrolytic copper conductors, conforming to IS: 8130- 1984 and insulation conforming to IS: 5831- 1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm size PVC medium grade surface/recessed casing capping conforming to IS: 537 (Part 3)-1983, colour-coded as specified in IS: 11353-1985, and including modular cover plates complete all as specified in IS: 732- 1989, complete all as specified and directed by Engineer-in-Charge. Note:- (i) Existing Modular sheet metal box should not be removed (ii) Mounting plate and cover plate of existing size is to be replace and rate are deemed to be included in quoted rate. | ||||||
Updated dates
Tender Value
₹44.1 L
EMD Value
₹88,500
Closing Date
9 Apr 2026, 6:00 pmClosed
GE (I) CG PORBANDAR
COAST GUARD DHQ NO 1, OPP BIRLA FACTORY
REPAIR MAINTENANCE OF INTERNAL ELECTRIFICATION EXTERNAL ELECTRIC SUPPLY EXTERNAL WATER SUPPLY HT VCBS RMU AND CSS MAINTENANCE TO LT PANELS APFC PANELS AND MISC ITEMS AT DHQ NO 1 AND CG JETTY UNDER GE (I) CG PORBANDAR
2026_MES_756232_1
8125A/E8
Open Tender
Electrical and Maintenance Works
180 days
PORBANDAR
AS PER NIT
10 documents required · 10 mandatory
₹500
GE (I) CG PORBANDAR
₹88,500
Yes
11 May 2026
13 Mar 2026
11 Apr 2026
13 Mar 2026
9 Apr 2026
28 Mar 2026
Schedule 'A'
Taking down carefully burnt out aluminium/copper point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, fluorescent tube light fittings etc., to be measured and paid for separately) removing materials to store for schedule of credit and making good to the disturbed surfaces of walls ceilings and floors etc., complete all as specified and directed by Engineer-in-Charge.
Disconnecting of unserviceable sub main wiring of any size and including steel conduit and accessories & removing from site and making good the disturbed surfaces including painting, complete all as specified and directed by Engineer-in-Charge.
One light /fan/exhaust point controlled by one, one way switch
One light point controlled by 2, Two way switch
One 5 pin socket outlet 5/6 amps on the same board.
One 5 pin socket outlet 5/6 amps on independent board.
One bell point controlled by one, one way switch
All as per item No 4 above but One 16 Amp socket outlet, independent, with cables 4.0 mm² size
Supply & Fixing in replacement of modular type 6 Amp one-way SP switch, conforming to IS: 3854-1997 with finger proof terminal, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing replacement of modular type 16 Amp one-way SP switch, conforming to IS: 3854- 1997 with finger proof terminal, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing replacement of modular type 2/3 pin combined shuttered type 6 Amp socket conforming to IS: 1293- 2005, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing replacement of modular type 2/3 pin combined shuttered type 6/16 Amp socket conforming to IS: 1293- 2005, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing replacement of modular type 6 Amp bell-push conforming to IS: 8884- 1978 with finger proof terminal, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing replacement of Bell multi music type 230 Volt, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of modular type 120 W step fan regulator of 2 module size, conforming to IS: 11037-1984, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of 6 Amp, 250 V high quality robust surface/flush type polycarbonate/PVC ceiling rose, conforming to IS: 371- 1979, having 2/3 terminals and outside diameter not less than 63.5mm, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of Modular switch 2 way 6 Amp, 1 module, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of PVC Modular surface box, complete all as specified and directed by Engineer-in-Charge. of following size:-
1 or 2 Module of size 85mm x 85mm
3 Module of size 85mm x 115mm
4 Module of size 85mm x 145mm
6 Module of size 132mm x 135mm
Supply and fixing in replacement of Modular cover plate with frame, complete all as specified and directed by Engineer-in-Charge. of following size:-
1 or 2 Module of size 85mm x 85mm
3 Module of size 85mm x 115mm
4 Module of size 85mm x 145mm
6 Module of size 132mm x 135mm
Supply & fixing in replacement switch piano flush button, 240 volts, 6 Amps, single pole, one way (ISI marked), complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of Socket outlet 2 in 1, 3 pin, 5 Amp flush type (ISI marked), complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Socket outlet 3 pin, 16 Amp, flush type, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of switch piano flush button 230 V, 16 Amps, Single pole, one way ISI marked, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of MCB DB sheet enclosure double door type, single pole and neutral 240 V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 16 way type, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of MCB DB sheet enclosure double door type, single pole and neutral 240 V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 12 way type, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of MCB DB sheet enclosure double door type, single pole and neutral 240 V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 8 way type, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of MCB DB sheet enclosure double door type, single pole and neutral 240V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 4 way type, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of MCB DB sheet enclosure double door type, triple pole and neutral 415 V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 6 way type, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and directed by Engineer-in-Charge. of following size:-
MCB 6 to 32 Amps, single pole
MCB 32Amps, double Pole / SPN
MCB 40 to 63 Amps, double Pole / SPN
Supply and fixing in replacement of 415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning, complete all as specified and directed by Engineer-in-Charge.
MCB, TP 25 to 63 Amps
MCB, TPN / FP 16 to 32 Amps
Material & Labour for sub-main wiring using ISI marked 1.1 kV grade single core FRLS flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831-1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm size in existing conduits / PVC Casing capping surface/recessed conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall / ceiling / floor with painting, complete all as specified and directed by Engineer-in-Charge. NOTE: 01 run of phase conductor, 01 run of neutral conductor, 01 run of earth continuity conductor and 01 run of PVC Casing capping shall be measured as one length.
2 x 6.0 Sqmm + 1 x 6.0 Sqmm earth wire
2 x 4.0 Sqmm + 1 x 4.0 Sqmm earth wire
2 x 2.5 Sqmm + 1 x 2.5 Sqmm earth wire
Material & Labour for sub-main wiring using ISI marked 1.1 kV grade single core FRLS flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm size in existing conduits / PVC Casing capping surface/recessed conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor with painting, complete all as specified and directed by Engineer-in-Charge. NOTE: 03 run of phase conductor, 01 run of neutral conductor, 02 run of earth continuity conductor and 01 run of PVC Casing capping shall be measured as one length.
4 x 6.0 Sqmm + 1 x 6.0 Sqmm earth wire
4 x 4.0 Sqmm + 1 x 4.0 Sqmm earth wire
Supply and fixing in replacement of casing capping of 25mm x 12mm size, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of casing capping of 32mm x 16mm size, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of wall mounted LED Tube light fitting 1 x 10 W LED (6500K), 2 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of wall mounted LED Tube light fitting 1 x 20W LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of LED Luminaires recessed mounted down lighter 18 watt 5700K system efficiency not less than 100lm/watt, thd<10% single phase including connecting cable from ceiling rose to terminal block of luminaires, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of 6 W LED down light with multiple beam tilting angles, no UV radiation and dimmable ballast, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of square shape slim recessed mounted LED down light of capacity 36 Watt (2ft x 2ft) with die cast housing finished in white powder coating, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of square surface mounted LED down light of capacity 36 Watt (2ft x 2ft) with die cast housing finished in white powder coating, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of 80 Watt LED bay light made of PDC aluminium housing with direct modular IP Lens, potted driver, 10 KV SPD, IP66 and with system efficacy of 12lm/ including connecting cable from ceiling rose to terminal block of luminaires, complete all as specified and directed by Engineer-in-Charge.
Taking down ceiling fan 1200mm/1400mm sweep and Exhaust fan upto 250mm sweep complete servicing, painting of fan blade and body, repair of fan motor and replacement of worn out parts such as capacitor and bearing hanging of ceiling fan/Exhaust fan in situ, complete all as specified and directed by Engineer-in-Charge. Note: (i) Rewinding of fan motor will be measured and paid separately.
Dismantling of fan (1200mm sweep) motor, cutting of burnt winding of rotor and rewinding with same gauge copper wire winding with insulated material and reassembling, complete all as specified and directed by Engineer-in-Charge.
Dismantling of Exhaust fan 250/300mm sweep motor, cutting of burnt winding of rotor and rewinding with same gauge copper winding wire with insulated material and reassembling, complete all as specified and directed by Engineer-in-Charge.
Dismantling of Exhaust fan Plastic Body 250/300mm motor, and replace with new motor and reassembling, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of BLDC fan Printed circuit board(PCB) assembly with remote for 1200mm sweep suitable for existing, complete all as specified and directed by Engineer-in-Charge.
Supply only capacitor 2.5/3.15 mfd AC 230 volts for ceiling fans 1200/1400mm sweep and any make, complete all as specified and directed by Engineer-in-Charge. Make:- Epcos/ Unistar/ Usha/Bajaj or equivalent
Supply only capacitor 4 mfd suitable for exhaust fans 250/300mm sweep, complete all as specified and directed by Engineer-in-Charge. Make:- Epcos/ Unistar/ Usha/Bajaj or equivalent
Supply and fixing in replacement of ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm, complete all as specified and directed by Engineer-in-Charge.
Dismantling electric/water connection and taking down of storage type water heater, servicing, cleaning of inner tank etc. at site and replacement of burnout parts etc. and re-fixing in situ, complete all as specified and directed by Engineer-in-Charge. Note- worn out parts shall be measured as separately.
Supply & Fixing spare parts of Geyser and including taking down old unserviceable Part
Supply only Heating element 1.5 KW with rubber gasket.
Supply only Thermostat as per sample/suitable to 25 Ltrs capacity ISI marked.
Supply only Hot/Cold water connection pipe 450 mm length.
Supply only Geyser assembly as per sample suitable for 25 ltr capacity Make: Bajaj Model : Cladia
Supply only Indication lamp red and green suitable for geyser as required
16 Amps top plug suitable as per existing socket
Supply and fixing in replacement of electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc., complete all as specified and directed by Engineer-in-Charge.
Material & Labour for annual servicing of Split Air conditioner cap 1.5/2.0 ton by disconnecting electric connection from its stabilizer or its electric board and remove the front cover or indoor AC unit and cleaning it with pressurized water and nylon brush, re-fixing the front cover of indoor unit. Remove the outer cover of outdoor unit and covered the condensing unit with ploythene/plastic cover so that water shall not be entered in the motor while cleaning the unit and filter with pressurized water then apply one coat of descaling solution and clean with wire mesh brush/nylon brush to the condensing coil of outdoor unit and greasing of all moving parts. Cleaning of Cooling and condenser coil of indoor and outdoor unit shall be properly carried out without damaging other parts. Checking and making serviceable electrical connection of DBs, Stabilizer, wiring of ACs as per site condition and tightening all electrical connection, complete all as specified and directed by Engineer-in-Charge. Note:- Replacement of defective parts with new parts shall be measured and paid separately under respective items in the schedule.
Taking down of outdoor/indoor unit of split type AC of capacity 1.5 tonne by duly dismantling copper coil, electrical connections mounting etc. and re-installing the same in new position with replacement MS bracket, and toping up of refrigerant gas and other items as per site requirement, complete all as specified and directed by Engineer-in-Charge.
Material and labour for maintenance of air conditioner 1.5/2.0 ton capacity, Split type unit with replacement of old/unsv spare parts mentioned as under or as per manufacturer instructions including testing on load, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair over load protector suitable range and capacity
Supply & Fixing in repair Running capacitor of 36/45/50/60 + 5/6 mfd suitable for 240 volts 50 HZ AC Supply
Supply & Fixing in repair capacitor of 2.5 mfd suitable for blower fan motor of 1.5/2.0 ton AC
Supply & Fixing in repair thermostat switch of suitable for 1.5/2.0 ton AC
Supply & Fixing in repair Contactor relay of suitable for 1.5/2.0 ton AC
Supply & Fixing in repairs Blower motor of 1/7 HP to 1/6 HP 230 volts 930 RPM, 20 Watt, 3 speed for indoor unit of split AC 1.5/2.0 TR of existing make complete
Supply & Fixing in repairs condenser fan motor 1/8 to 1/12 HP, 900/1400 RPM, 60 Watt suitable for 1.5/2 TR split AC outdoor unit, single phase, of existing make complete. Make:- LG/Blue-star/Voltas or as per existing make of AC at site.
Supply & Fixing in repairs Pre-air filter made up of PVC for indoor unit of split AC suitable for any make and description complete
Supply & Fixing in repairs PVC fan blower assembly for 1.5 /2TR split AC's any make
Supply & Fixing in Replacement of Printed circuit board(PCB) with suitable for non-inverter type Split AC 1.5/2.0 TR of any capacity, model and make as per existing complete with necessary electrical connection.
Material & Labour for replacement of defective cut open compressor/Uncut compressor suitable for air conditioner with new compressor filled with capila D and charging of refrigerant gas up to required capacity after flushing the complete refrigerant system including repair to leakage if any in refrigerant piping and replacement of filter complete for split type AC's, complete all as specified and directed by Engineer-in-Charge. of the following capacity
1.5 ton capacity
2.0 ton capacity
Supply & Fixing in repairs/replacement of condenser fan motor for outdoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repairs / replacement of blower motor for indoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of Printed circuit board(PCB) with hand set of indoor and display unit suitable for Inverter type Split AC 1.5/2.0 TR of any capacity, model and make as per existing complete with necessary electrical connection, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repairs of Printed circuit board(PCB) with hand set of outdoor and display unit suitable for Inverter type Split AC 1.5/2.0 TR of any capacity, model and make as per existing complete with necessary electrical connection, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of outdoor condenser unit of copper with 2 run of copper pipe of outdoor unit of split type AC 1.5/2.0 TR, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of swing motor 230 Volt for 1.5/2.0 Ton indoor unit of split AC, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repairs Blade set of fan motor of outdoor unit, made out of Aluminium sheet Suitable for shaft bore dia 1/2" and fan dia 16"/ 18" in existing air conditioner split type, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repairs Blade set of fan motor of outdoor unit, made out of PVC Suitable for shaft bore dia 1/2" and fan dia 16"/ 18" in existing air conditioner split type, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repairs copper tubing of size 3/8" suitable for split AC with nitrile self-adhesive foam wrapped with PVC insulation all around the pipe line, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repairs copper tubing of size 5/8" suitable for split AC with nitrile self-adhesive foam wrapped with PVC insulation all around the pipe line, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair flexible PVC pipe for condense water outlet for Split AC as per existing, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for charging of refrigerant R-410/R-22/R-32 gas to air conditioner or as per existing /manufacturer instructions suitable for split air conditioner cap 1.5 ton after flushing out the entire refrigerant, vacuum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas, as per manufacturer instructions, as mentioned above, complete all as specified and directed by Engineer-in-Charge.
All as per item no 66 above but for 2.0 ton capacity complete as per manufacturer instructions, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of remote for split AC 1.5/2 Ton unit suitable for existing make and model including with battery, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of outdoor unit stand of metal including fixing accessories such as nut bolt washers and fastener for 1.5/2 Ton outdoor unit, complete all as specified and directed by Engineer-in-Charge.
Material and labour for servicing/cleaning of water cooler of storage capacity/ nominal cooling capacity(Ltrs/hr) 80/40 & 120/60 litres with the use of anti-scaling agent for internal steel water tank, outer body and condenser coil of water cooler, Removal of dust and other deposited material for the various functional equipment using smooth nylon brush, cleaning of drainage for speedy water removal and checking of electrical connection to compressor and other electrically operated equipment’s, cleaning of fins and tubes of condenser, repair/replacement of PUF thermal insulation, checking of refrigerant leakage and functionality of water tap, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing hermetically sealed compressor of water cooler of capacity 40 ltr/hr suitable for R134a gas, single phase alongwith capacitor and relay, including gas charging in the system and testing of water cooler, complete all as specified and directed by Engineer-in-Charge. Make:- Copeland/Tecumseh. Note : Cost of cutting of existing worn out compressor will be deemed to be included in unit rate.
Taking out burnt unserviceable condenser fan motor, and replacement with new electric motor, single phase 230V of water cooler 40ltrs/hrs with condenser fan blade, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of following items of water cooler
Thermostat for water cooler capacity 40/80 ltr/hrs.
Push type Bib tap Cast copper alloy 15mm Push type chromium plated.
PVC Connection with brass unions at both ends with brass nuts, suitable for fixing to 15mm dia GI Pipe.
Supply & Fixing in repair / replacement of over load protector suitable range and capacity for Refrigerator
Material and labour for carrying out repair /maintenance/ servicing of Refrigerator of any capacity by periodic cleaning of internal and external parts, cleaning of water collection area and checking of electrical circuit repair/ replacement of unserviceable/worn out spares and accessories to make the Refrigerator in good working condition, complete all as specified and directed by Engineer-in-Charge. Note: Defective spares required for replacement shall be measured and paid separately under respective items.
Material and labour for maintenance of Refrigerator any capacity with replacement of old/unsv spare parts as under including testing on load, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair condenser suitable for Refrigerator of 195/ 250/ 300 ltr cap
Supply & Fixing in repair cooling effect transmitting fan motor suitable for Refrigerator of 195/ 250 / 300 ltr cap
Supply & Fixing in repair Compressor Relay suitable for Refrigerator of 195/250 / 300 ltr cap or as per existing Make KCL/Rentrol/Indofos
Supply & Fixing in repair thermostat suitable for Refrigerator of 195/250 / 300 ltr cap
Supply & Fixing in repair Compressor suitable for Refrigerator of 195 / 300 ltr cap or as per existing
Supply & Fixing in repair frost free fan motor suitable for Refrigerator of 195 / 300 ltr cap or as per existing
Supply & Fixing in repair defrost timer suitable for Refrigerator of 195 / 300 ltr cap or as per existing
Material & Labour for charging of refrigerant R-134a gas to Refrigerator for the following capacities as per existing /manufacturer instructions after flushing out the entire refrigerant, vacuum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas, as per manufacturer instructions, as mentioned above, complete all as specified and directed by Engineer-in-Charge. Refrigerator cap 230/250 Ltrs
Earthing complete with galvanised steel earth plate electrode 60cm × 60cm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less ‘than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to Earthing test point all as specified or indicated including testing on completion, including taking down old unserviceable Earthing, complete all as specified and directed by Engineer-in-Charge.
Servicing of DG set ('C' Check) of Cap 20 KVA to 25 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system, complete and rectification of defect if any and including replacement of following, complete all as specified and directed by Engr-in-Charge. (a) Diesel Filter (b) Oil Filter (c) Coolant ( Top up) (d) Lubrication oil (top up) Make of DG set: Ashok Leyland/ Greaves Cotton/ kirloskar/Mahindra Note: Defective parts if any other than listed at (a) to (d) above will be measured and paid separately
Servicing of DG set ('C' Check) of Cap 62.5 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system complete and rectification of defect if any and including replacement of following, complete all as specified and directed by Engr-in-Charge. (a) Diesel Filter (b) Oil Filter (c) Coolant ( Top up) (d) Lubrication oil (Top up) Make of DG set: Ashok Leyland/ Greaves Cotton/ kirloskar/Mahindra Note: Defective parts if any other than listed at (a) to (d) above will be measured and paid separately
Supply only parts / Items of DG set 20-62.5 KVA, including taking down old unserviceable Part, complete all as specified and directed by Engr-in-Charge.
Engine Oil 20W / 40 Make : Castrol/Servo/IOC/HP
Coolant
AVR of DG for 20/25 KVA capacity including with connection complete all as specified and directed by Engineer-in-Charge.
AVR of DG for 62.5 KVA capacity including with connection complete all as specified and directed by Engineer-in-Charge.
Water Pump Assembly of any cap
V belt as per existing size
Hose pipe set
Battery Terminal
Fuel pipe
Material & Labour for DIOD assembly Set for 20/62.5 KVA DG Set, complete all as specified and directed by Engr-in-Charge.
Material & Labour for servicing checking the connection of main rotor of DG Set, cleaning the dust particle, complete all as specified and directed by Engr-in-Charge.
Materials and labour for scraping removing and cleaning old rusty paint from enclosure of DG set 20 KVA to 62.5 KVA capacity any make by cleaning agents & painting the above DG set complete with Polyurethane (PU) paint, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement battery heavy duty 12 volts 80 / 88 AH maintenance free, complete all as specified and directed by Engr-in-Charge.
Supply, laying and replacement of jointing in trenches DI pipes class K-7 of standard length spigot and socketed end push type joint with rubber gasket as jointing material, internal cement mortar coating an external surface with bituminous paint of size 100mm dia ISI, complete all as specified and directed by Engr-in-Charge.
Supply, laying and replacement of jointing in trenches DI pipes class K-7 of standard length spigot and socketed end push type joint with rubber gasket as jointing material, internal cement mortar coating an external surface with bituminous paint of size 80mm dia ISI, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of size 110mm outer dia, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of size 50mm outer dia, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of size 32mm outer dia, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of size 25mm outer dia, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in repair of size 50mm dia, PP-R Ball valves (brass insert) as per requirement of the site, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in repair of size 32mm dia, PP-R Ball valves (brass insert) as per requirement of the site, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in repair of size 25mm dia, PP-R Ball valves (brass insert) as per requirement of the site, complete all as specified and directed by Engr-in-Charge.
Supplying and laying in replacement of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches, complete all as specified and directed by Engr-in-Charge. of following sizes:
20mm dia
40mm dia
Taking down GI tubing 80 to 100mm bore of any description, complete all as specified and directed by Engr-in-Charge.
Material and labour for GI tubing 100mm dia medium grade galvanized with all fittings fixed on wall / ceiling / structure complete in trenches, complete all as specified and directed by Engr-in-Charge.
Material and labour for GI tubing 80mm dia medium grade galvanized with all fittings fixed on wall / ceiling / structure complete in trenches, complete all as specified and directed by Engr-in-Charge.
Material and labour in replacement of ISI marked ductile iron socketed fittings supplied as per IS: 9523/2000 of class K-12, PN-10 for pressurized water delivery with inside Cement Mortar lining and outside zinc followed by black bitumen coating for size 80mm dia to 150mm dia such as bends, Tapers tale pieces, Tee pieces (single branch) Y junction double branch, cross collars, caps and plug set including rubber ring push on joints, complete all as specified and directed by Engr-in-Charge.
Material and labour for rubber gasket (Tyton) joints suitable for 100mm bore CI/DI pipe and fittings including jointing material, complete all as specified and directed by Engr-in-Charge.
Material and labour for rubber gasket (Tyton) joints suitable for 80mm bore CI/DI pipe and fittings including jointing material, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of sluice valve 100mm dia class PN 1.6, cast iron body flanged type including fitting with suitable size of nut, bolts, washer and rubber gasket, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of sluice valve 80mm dia class PN 1.6, cast iron body flanged type including fitting with suitable size of nut, bolts, washer and rubber gasket, complete all as specified and directed by Engr-in-Charge.
Supply only ball bearing suitable for 10 HP of mono-block/pump set motor, complete all as specified and directed by Engr-in-Charge.
All as per Sl. item No. 106 here in above but capacity upto 5 HP, complete all as specified and directed by Engr-in-Charge.
Supply in replacement of bush/bearing (gun metal) of suitable size for 7.5 to 15 HP for the submersible motor, complete all as specified and directed by Engr-in-Charge.
Supply in replacement of stainless steel sleeve of suitable size for 7.5 to 15 HP, complete all as specified and directed by Engr-in-Charge.
Supply in replacement of thrust plate set 7.5 to 15 HP, complete all as specified and directed by Engr-in-Charge.
Dismantling and opening/ Repair and re-fixing of defective submersible pump set bowl assembly of any size 7.5 HP and reassembling after repairing by lathe work and other machinery work as required and replacement of studs, nuts, bolts etc., re-fixing the same after making it serviceable in its existing position including test and commissioning, complete all as specified and directed by Engr-in-Charge. Note: Defective spare parts of bowl assembly shall be measured and paid under relevant items.
Supply only submersible pump bowl assembly of gun metal impeller suitable for 7.5 HP to 10 HP, complete all as specified and directed by Engr-in-Charge.
Supply only submersible intermediate bowl suitable for 7.5 HP to 15 HP, complete all as specified and directed by Engr-in-Charge.
Supply only submersible bowl bush (rubber) suitable for 7.5 HP to 15 HP, complete all as specified and directed by Engr-in-Charge.
Supply only submersible bowl bush (gun metal) suitable for 7.5 HP to 15 HP, complete all as specified and directed by Engr-in-Charge.
Supply only submersible cast iron impeller seal ring (neck ring) suitable for 7.5 HP to 15 HP, complete all as specified and directed by Engr-in-Charge.
Supply only submersible stainless steel running sleeves (off size) suitable for 7.5 HP to 15 HP, complete all as specified and directed by Engr-in-Charge.
Supply only submersible impellor locking keys stainless steel (off size) suitable for 7.5 HP to 15 HP, complete all as specified and directed by Engr-in-Charge.
Supply only submersible pump set shaft upto16mm to 25.40 mm dia of any capacity suitable for 7.5 HP to 15 HP, complete all as specified and directed by Engr-in-Charge.
Material and labour in replacement of submersible flat cable stranded copper conductor PVC insulated PVC sheathed 3 core flat size, 4 Sqmm, 1100 volts, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing DOL starter Three phase with MCB, over load relay, contactor capacitor, voltmeter, ammeter ON and OFF push button including fixing arrangement suitable for 5 HP submersible pump, complete all as specified and directed by Engr-in-Charge. Make: L&T/Bentex/Seimens.
Water Testing, Collecting the sample of water at Pump house and testing of water for iron, PH value, TDS, colour, Total Hardness, chloride, Chlorine, fluoride, Coliform, arsenic test and submitting the test report from reputed laboratory, complete all as specified and directed by Engr-in-Charge.
Supply only Hypochlorous Acid net wt 38 kg, high strength chlorination chemical for water disinfectant in any form granular or in liquid form in factory sealed HDPE container (45/50 Kg 45 Kg container), chlorine concentration level 40-60% 65-70 % and delivered at STP, complete all as specified and directed by Engr-in-Charge.
Supply only Bleaching powder suitable for disinfection, complete all as specified and directed by Engr-in-Charge.
Supply only Swimming Pool Alum Powder of approved Make by Accepting Officer, complete all as specified and directed by Engineer-in-Charge.
Supply only TCCA of approved Make by Accepting Officer, complete all as specified and directed by Engineer-in-Charge.
Supply only Swimming Pool Aigiecide in 05 Liters Can of approved Make, complete all as specified and directed by Engineer-in-Charge.
Carry out water testing of bacterial, chemical and biological analysis of sewage water treated water from NABL accredited Govt approved lab for following parameters and submission of test reports all as directed. (a) PH(b) Chemical Oxygen demand/COD(c) Biological Oxygen Demand/BOD(d) Total Suspended solids(e) Oil and grease(f) TKN(g) Total Coliform(h) Organism MPN(k) Dissolved OxygenNote: Every Quarterly water testing shall be carried out as per CA Qty in period of contract all as directed without fail else recovery will be made at Rs 15000/- per test for execution of item and for non-submission of Test Report.
Supply only ball bearing suitable for 3/5 HP of mono-block/pump set motor, complete all as specified and directed by Engr-in-Charge.
Supply in replacement of bush/bearing (gun metal) of suitable size for 5 HP for the Sewage submersible motor, complete all as specified and directed by Engr-in-Charge.
Taking down air blower of Air blowers with working pressure 0.3 Kg/cm2 alongwith motor of capacity 5HP with blower pipe of size 3", from the existing position after disconnecting all electrical connection and transportation to workshop for repair for un-serviceable parts complete and removing the defective parts, repair the air blower thoroughly including machine work and re-assembling the air blower and commissioning testing complete on full load, complete all as specified and directed by Engr-in-Charge. (new spares will be measured and paid separately).
Supply & Fixing in replacement of "V" Belt (SPA 1250) unserviceable /worm-out 'V' belt of air blower etc, complete all as specified and directed by Engr-in-Charge. Makes:- Fenner/Dunlop/Nerlon/Super flix/Ecodrive.
Material & Labour in replacement of Gear oil 90 EP, Pressure Gear Oil etc., complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of air-filter for blower suitable size for existing air-filter etc, complete all as specified and directed by Engr-in-Charge.
Supply only Grease 30K, for using ensure protection of mental surfaces extending bearings, hinges etc., complete all as specified and directed by Engr-in-Charge.
Material and labour for painting of the transformer 100 KVA to 400 KVA, RMU, VCB and CSS Body complete by removing old paint by scrapping and providing spray painting with epoxy paint of approved (suitable for existing colour) make duly marking/writing MES/SM No., complete all as specified and directed by Engr-in-Charge.
Material and labour for painting of the transformer 500 KVA to 1000 KVA, RMU, VCB and CSS Body complete by removing old paint by scrapping and providing spray painting with epoxy paint of approved (suitable for existing colour) make duly marking/writing MES/SM No., complete all as specified and directed by Engr-in-Charge.
Taking out UNSV HT UG cables of any sizes from trenches, complete all as specified and directed by Engr-in-Charge.
120 Sqmm 3 Core
185 Sqmm 3 Core
240 Sqmm 3 core
Supply & Fixing in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for Straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable, complete all as specified and directed by Engr-in-Charge. for following size of cable
95 Sqmm 3core
120 to 185 Sqmm 3core
240 Sqmm 3core
Supply & Fixing in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for Indoor type termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to185 Sqmm, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for Outdoor type termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to185 Sqmm, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement air break switch triple pole, 11KV, mechanically operated mounted on polymeric insulators and steel frame, with operating mechanism worked from ground level, for current rating up to 200 amps complete with including insulators horizontal /vertical rod and operating pipe of suitable size and length including taking down the old unserviceable air break switch, jumper connections and reconnecting of suitable size and length and making connection to new AB switch gang operated, complete all as specified and directed by Engr-in-Charge. Make: Jaipuria / Atlas / Pactil
Supply & Fixing in replacement of Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo am for 11 KV (triple pole set -1)as per existing make and model and directed at site, complete all as specified and directed by Engr-in-Charge.
Preventive Maintenance and Servicing, 11/0.433 KV Step down Transformer Indoor and Oil Cooled type by disconnecting carefully electric connection on primary & secondary side, Checking both side HT bushing, bushing rod, opening top cover of the transformer by unscrewing nuts, bolts, washers etc., rectify the oil leakages issues, if noticed any from the entire body of the transformer, during servicing and re-fixing the top cover of transformer according to previous system. Servicing of the transformer must be done through OEM or authorised personnel including maintaining and submitting the inspection and testing records of each transformer to the Engr-in-Charge. 100 to 630 KVA Note 1. :- Inspection of transformer shall involve :-(a) Checking of all clamps, nuts, bolts including core bolts & cover fixing bolts etc. (b) Checking all brazings, joints, tap heads, gaskets and connection joints. (c) Checking all terminations / connections inside/outside the transformer.
(d) Checking of off load tap changer assembly, checking the moving and fixed contacts for contact wear and connection to winding. (e) Conducting the test on core and windings as per IS like ratio, magnetic imbalance, short circuit, IR Value, High Voltage Test etc. in presence of Engr-in-Charge. Note 2. : Spares used bushes studs HT/LT, bushing rod HT/LT, transformer oil, filtration of oil, buchholtz relay, Gaskets set, Off Load Change over switch etc., will be measured and paid separately under respective item of BOQ. Note 3 :- The rates quoted against the item is deemed to be included for cost of Labour for lifting/transporting to civil workshop and vice-versa, if required as per site requirement.
Material & Labour for Dehydration/Filtration of transformer oil at site by means of centrifuging machine in order to improve dielectric strength of oil as per IS-355. Break down voltage should not be less than 50 KV, complete all as specified and directed by Engr-in-Charge.
Material & Labour Transformer oil having di-electric strength of 60 KV as per IS complete for top up/ replacement, complete all as specified and directed by Engr-in-Charge. (Oil should be supplied in sealed barrel of Power/Transol brand) Note: oil shall be filled in the transformers/stabilizers to be repaired or installed at site at different locations.
Supply & Fixing in replacement of Silica Gel (Moisture absorbent chemical ) for breather of transformer 11 KV /433 Volt of any make / rating, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of oil temperature indicator gauge suitable for transformer of capacity 11KV/433 Volt, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of LT bushings with brass studs complete washer with nuts bolts and washers of brass of suitable size for 200 KVA to 630 KVA transformer, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of HT bushing with brass studs complete washer with nuts bolts and washers of brass of suitable size for 200 KVA to 630 KVA transformer, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of lightning arrester suitable for 11 KV as per existing make and model and directed at site, complete all as specified and directed by Engr-in-Charge.
Material & Labour for Maintenance/Over hauling of HT VCB 11 KV by taking shunt down with prior intimation and cleaning of HT VCB by using air blower, tightening the control circuit, Checking the all fuses, to ensure the smooth functioning of HT VCB by employing the Skilled trades man and helper, complete all as specified and directed by Engr-in-Charge. Note: Rate Include following (i) Replacement of small piece of wire of sq area up to 1.5 sqmm Control Ckt cable) of Max length 5 Mtrs and replacement of unserviceable indicator lamps as per colour code all as specified and as directed by Engineer - In - Charge. (ii) Rack out /Down the HT VCB kept in Test position, Check the megger value of VCB terminals with body by suitable HT megger of range 5000 Volt and check the serviceability of Earthing connection by Earth megger note down the readings.
Supply & Fixing in replacement of charging motor suitable for 11 KV VCB 630/800 Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of closing coil 24 Volt DC suitable for 11 KV VCB 630/800 Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of Tripping coil 24 Volt DC suitable for 11 KV VCB 630/800Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of master Trip Relay 110 volt DC suitable for 11 KV VCB 630/800 Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of Auxiliary Relay 110 volt DC suitable for 11 KV VCB 630/800Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of vacuum bottle suitable for 11 KV VCB 630/800 Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of Finger contacts for 2 Nos suitable for 11 KV VCB 630/ 800 Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of indication LED lights for each phase of 230 Volt, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of indication panel suitable for 11 KV VCB 630/800 Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of protection Relay (over short Circuit /earth fault) 110 volt DC suitable for 11 KV VCB 630/800 Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement bus bar spout top for RYB suitable for 11 KV VCB 800 Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement bus bar spout Bottom for RYB suitable for 11 KV VCB 800 Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of space heater and Thermostat set suitable for 11 KV VCB 800 Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of male and female spout suitable for existing PT, for 11 KV VCB of cap 630 Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of HT 11 KV drop out fuse assembly with insulator and base including fuse tube, fuse carrier top connectors incoming and outgoing connectors, complete all as specified and directed by Engr-in-Charge. Note: Rate include taking down existing unserviceable/ Faulty DO fuse assembly and fix the new one and make the incoming and outgoing connections and switch on the supply through the new DO fuse assembly all as directed by EIC.
Material & Labour for preventive maintenance of HT ring main unit at main receiving substation comprising of one incoming Two out going as per manufacture specification, work is to be carried out with prior intimation, and taking shut down of Ring main unit, earth the unit completely, complete all as specified and directed by Engr-in-Charge. Scope of work consist of following (a) Check and clean termination and bushing compartment (b) Checking of sealing of gland plate area (c) Checking of mechanical interlock (d) Check close and trip coil condition and gap setting (e) Checking of control circuit , fuses and Electrical interlocks (f) Following test should be carried out at site (i) Test the insulation testing of each Breaker/Isolator (ii) Test Test contacts of breaker and isolators (iii) Check /Reset the relays (g) Checking/Testing of Relays as per following (i) Functional verification of Individual feeder by switch On /Off by both incoming so as to confirm with both incoming unit is functional (ii) Check the auxiliary supply and control voltage , (iii) Check the power pack unit and its Voltage. (iv) Check the CT connections, inspection and testing of closing and trip coil by using external test kit. Note: Contractor has to submit the inspection report to department after completion of work
Supplying and laying in replacement of synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 25x20cm size, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole, complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth and getting out in hard/dense soil, complete all as specified and directed by Engr-in-Charge.
Returning filling in including spreading levelling watering and well Ramming in layers not exc 25 cm thick, complete all as specified and directed by Engr-in-Charge.
Removing excavated material not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point, complete all as specified and directed by Engr-in-Charge.
Material & Labour for cutting existing road/hard standing not exc 45 x 45 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well ramming watering finish surface 10 cm from top using PCC 1:2:4; including removal of surpluses soil, complete all as specified and directed by Engr-in-Charge.
Servicing and repair of APFC panel upto 300 KVAR by replacement of worn out spare parts and cleaning of the serviceable contactors and tightening/ checking of all internal electrical connections and accessories to maintain PF not less than 0.99 by adjusting/ calibrating the APFC relay of any type, complete all as specified and directed by Engr-in-Charge. Note: Defective parts if any will be measured and paid separately.
Supply & Fixing in replacement of heavy duty gas filled Capacitor 5 KVAR, 440V, 3 phase, 50 Hz, complete all as specified and directed by Engr-in-Charge. Make: L&T/Epcos/Schneider/C&S
Supply & Fixing in replacement of heavy duty gas filled Capacitor 10 KVAR, 440V, 3 phase, 50 Hz, complete all as specified and directed by Engr-in-Charge. Make: L&T/Epcos/Schneider/C&S
Supply & Fixing in replacement of heavy duty gas filled Capacitor 20 KVAR, 440V, 3 phase, 50 Hz, complete all as specified and directed by Engr-in-Charge. Make: L&T/Epcos/Schneider/C&S
Supply & Fixing in replacement of heavy duty gas filled Capacitor 25 KVAR, 440V, 3 phase, 50 Hz, complete all as specified and directed by Engr-in-Charge. Make: L&T/Epcos/Schneider/C&S
Supply & Fixing in replacement of 6 Steps APFC Relay, microprocessor based and connected items, complete all as specified and directed by Engr-in-Charge. Make: L&T/Epcos/Schneider/C&S
Material & Labour for apply two coat of epoxy paint on LT Panels of any size, including preparation of rusted surface of panel by means of sand paper/scrubbing of dust etc and apply one coat of epoxy based primer before painting, complete all as specified and directed by Engr-in-Charge. Note: Minor repair/ replacement of hinges suitable for screw fasteners and fixed in original position deemed to be included in unit rate.
Supply & Fixing in replacement of Digital time switches (SST 15 min) for street light 215 V single Phase, complete all as specified and directed by Engr-in-Charge. Make :L&T/Havells
Material & Labour in replacement of Cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (heat shrinkable) and accessories suitable for 3½/ 4 core XLPE armoured Al conductor, complete all as specified and directed by Engr-in-Charge. cable of following sizes- Make-Denson/Raychem/3M,
25 Sqmm to 50 Sqmm
70 Sqmm to 120 Sqmm
150 Sqmm to 185 Sqmm
Taking out UNSV LT UG cables of any sizes from trenches, complete all as specified and directed by Engr-in-Charge.
Supply & Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, complete all as specified and directed by Engr-in-Charge. of cross-sectional area:-
16 Sqmm 4 Core
25 Sqmm 4 Core
35 Sqmm 4 Core
50 Sqmm 3.5 Core
70 Sqmm 3.5 Core
95 Sqmm 3.5 Core
Material and Labour for DWC pipe laying in trenches/ under floor/on walls for protection of UG cables, complete with coupler and connected accessories, including taking down old unserviceable DWC Pipe, complete all as specified and directed by Engr-in-Charge. Note: Cutting of floor/ road and making good with PCC deemed to be included in item rate. of following sizes:- Make: Rex/Poly/Gemini
Supply & Fixing in replacement of MCB/MCCB FP, 415 V fixed type, including taking down of old unsv panel after disconnecting Existing cables and reconnecting the cables with proper lugs and glands, complete all as specified and directed by Engr-in-Charge. of following:- Make: Havells/ L&T / ABB /Schneider
MCCB 63/100 Amp FP, 415 V breaking capacity 25 KA
MCCB 200 Amp FP, 415 V breaking capacity 25 KA
MCCB 250 Amp FP, 415 V breaking capacity 36 KA
MCB 63 Amps FP, 415 V breaking capacity 10 KA
MCB 6 TO 32 Amps SP, 240 V breaking capacity 10 KA
Dismantling and taking down the existing defective street light /flood light fitting of any type and any capacity LED street light from steel tubular pole, opening the street light fitting, checking the serviceability, remove the cable carbon and replacement of 3 Core 1.5 Sqmm size multi-stranded copper conductor including taking down old unsv 3 Core 1.5 Sqmm size copper conductor, complete all as specified and directed by Engr-in-Charge. Note:- 1.5 Sqmm 3 core size multi-stranded copper conductor etc will be measured and paid separately.
Supply & Fixing in replacement of street light fitting LED type 70 watts with Pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening separate driver compartment with IP66 protection and including driver unit etc and taking down old unsv any size/watt of security light, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of LED flood Light fitting 150 watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, including taking down old light fitting of any description, complete all as specified and directed by Engr-in-Charge. Make: Wipro/Philips/crompton
Supply & Fixing in replacement of LED flood Light fitting 200 watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, including taking down old light fitting of any description, complete all as specified and directed by Engr-in-Charge. Make: Wipro/Philips/ Crompton
Supply & Fixing in replacement of LED ornamental street light with lens & spun aluminium designer housing with clear with clear acrylic for city beautification, IP65, and with system efficacy of 100lm/ w fitting 90 watt, fixed on existing pole & connecting, including taking down old light fitting, complete all as specified and directed by Engr-in-Charge. Make: Bajaj/Crompton / Wipro/ Halonix cat part no HLOSL-04-90CWL
Supply & Fixing in replacement of Multi standard Copper Conductor cable of size 1.5 Sqmm 3 Core, inclusive of all tees, bends, elbows, reducers and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for interconnection of cable light/looping box to street light fitting etc., complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in repair 4 pole power contactor MCX-13, 50 Hz, complete all as specified and directed by Engr-in-Charge. Make : L&T or equivalent
Supply & Fixing in repair power Relay MNX - A1, /MNX - A2, 50 Hz, and complete all as specified and directed by Engr-in-Charge. Make : L&T or equivalent
Supply & Fixing in replacement of Bldg Security light fitting LED type 25 watts with Pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening separate driver compartment with IP66 protection and including driver unit etc and taking down old unsv any size/watt of security light, complete all as specified and directed by Engr-in-Charge. Make: Wipro or equivalent from Bajaj/Philips
Supply & Fixing in replacement of LED Bollard 10W, IP 65, Die cast aluminium housing with polycarbonate cover, operating voltage 220-240 V, pole mounted, including PCC 1:2:4 type, base of size 300mm x 300mm and depth 500mm for fixing of Bollard with nuts bolts etc required as per site, complete all as specified and directed by Engr-in-Charge. Make : Crompton Cat No LBLSN-10-CDL or its equivalent in Bajaj/Wipro/Philips
Supply & Fixing in replacement of automatic street light switch (5 KW to 8 KW) Amps rating 20 Amps NATURE SWITCH for automatic switching of streets lights based on lux level of natural light. The sensor (nature switch) along with suitable power contactor, MCB and support terminals should be enclosed in pole /wall mountable enclosure made out of rust proof, electric shock proof, termite proof and FR grade special moulding compound conforming to IP-54. The contactor, MCB and circuit wiring 16/10 sqmm copper shall be suitable, complete all as specified and directed by Engr-in-Charge. Make :- Model No. SWADEEP-02EC-5KW, 3P (3 PHASE) of Healer or equivalent to Havells /L&T
Supply & Fixing in replacement of Pole box with 6 Amps MCB provision and suitable connector for single hose connections loop in and out 10 to 16 Sqmm 4 core aluminium armoured cable branch out 1.5 Sqmm single core copper PVC insulated cable enclosed in a thermoplastic polycarbonate enclosure which should be shock proof safe IP 66/67 weather proof, rust proof, dust proof, water proof, internally embedded gasket with provision for cable entry through IP 66/67 thermoplastic metric size glands and/or grommets enclosure size (155 x 210 x 92mm ), fixing arrangement and clamps including making connections, complete all as specified and directed by Engr-in-Charge. (Cat Part No KF 1616 G of Make : Hensel or equivalent model of Sintex)
Supply & Fixing in replacement of Aluminium lugs long barrel of size 185-240sqmm, complete all as specified and directed by Engr-in-Charge. Make: Dowells or equivalent
Supply & Fixing in replacement of Aluminium lugs long barrel of size 120-150 sqmm, complete all as specified and directed by Engr-in-Charge. Make: Dowells or equivalent
Supply & Fixing in replacement of Aluminium lugs long barrel of size 70-95 sqmm, complete all as specified and directed by Engr-in-Charge. Make: Dowells or equivalent
Supply & Fixing in replacement of Aluminium lugs long barrel of size 35-50 sqmm, complete all as specified and directed by Engr-in-Charge. Make: Dowells or equivalent
Supply & Fixing in replacement of Aluminium lugs long barrel of size 16-25 sqmm, complete all as specified and directed by Engr-in-Charge. Make: Dowells or equivalent
Material and Labour for painting the MS supporting structure of solar ON Grid power plant up to capacity 90/45/40/20KW, complete as per original shade with two coats of synthetic enamel paint over one coat of primer by spray gun after scrapping the existing paint, denting, filling depression with putty etc., complete all as specified and directed by Engr-in-Charge.
Material & Labour for bore Earthing 150mm bore for earthing with galvanised steel pipe electrode, 40mm bore, medium grade, 3 metres length, top edge of GI pipe not less than 1.25 metres below ground level, connected with Earthing lead of 25 x 4 mm GI strip to the earthing test point and filling of charcoal dust, salt etc., and testing on completion, including taking down old unserviceable earthing, complete all as specified and directed by Engr-in-Charge. Note: IR Value should be less than 5 Ohms. Note: GI earth stip of size 25 x 4 including installation 7.5 Mtr is deemed to be included in the unit rate.
Supply & Fixing in repair aluminium earth strip of size 25 x 3 mm with epoxy insulators and fixing screws etc for earth continuity conductors to test point terminal including taking down old strip, complete all as specified and directed by Engr-in-Charge.
Deployment of manpower, instrument, tools, and all connected accessories for testing of earth resistance of existing Earthing at provided earth test point for each earth set by competent calibrated digital earth test meter electronic type along with accessories (earth rod set with Cu wire with clips) and recording the result dully signed with date by MES representative and contractor, complete all as specified and directed by Engr-in-Charge.
NOTE:- (a) Testing of each Earthing shall be carried out at the interval of 3 months and measurement shall be done each time separately and test result shall be maintained dully signed with date by MES representative and contractor. (b) Pouring of water in each earth pit is deemed to be included in the rate quoted. (c) Necessary arrangement to be made by the contractor for pouring the water in earth pits. Vehicle reqd for carrying/storage of water (upto to the site) with helper will be arranged by contractor and deemed to be included in the rate quoted. (d) Cost of Maintenance of carrying vehicle (if any) and cost of fuel reqd for veh is deemed to be included in the rate quoted.
Supply & Fixing in replacement of thermoplastic polycarbonate three phase connector 415 vols, IP 65/66 electric shock proof for street light pole mounted on steel channel including provision of 6 Amps SP MCB complete fixing arrangement all, complete all as specified and directed by Engr-in-Charge.
Material & Labour for marking of Earthing pit (GI earth / Copper earth / Chemical earth) with two or more coat synthetic enamel paint, colour & pattern as approved by the Engr-in-Charge, Letter size shall not be less than 50 mm, complete all as specified and directed by Engr-in-Charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
8125AT.pdf
Tender Documents • 4.00 MB
BOQ_847073.xls
BOQ • 0.51 MB
Download all tender documents and submit your bid