Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 CrAccepted-AOC BAJUGAON CITY TOWN GOSSAIGAON P O JARAGURI P S GOSSAIGAON DIST KOKRAJHAR PIN 787000 | 787000 | ₹21.9 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹22.5 CrRejected-AOC | ₹22.5 Cr | L2 | Rejected-AOC L2 |
Tender Value
₹21.2 Cr
EMD Value
₹42.4 L
Closing Date
23 Jan 2024, 2:00 pmClosed
The Addl. Chief Engineer cum Director, PWD BTC
O/o the Addl. Chief Engineer cum Director, PWD, BTC, Kokrajhar.
Development of State Guest House at Kokrajhar, BTC under Grant to BTC for infrastructure Development Fund for the financial year 2022-23.
2024_BTC_35141_1
125/ACE/NIT/Infra/BTC/2022-23
Open Tender
Civil Works - Building
730 days
Kokrajhar
Please refer Tender documents.
4 documents required · 4 mandatory
₹20,000
₹42.4 L
Yes
O/o the Addl. Chief Engineer cum Director, PWD BTC
21 Mar 2024
3 Jan 2024
24 Jan 2024
3 Jan 2024
23 Jan 2024
3 Jan 2024
3 Jan 2024 - 23 Jan 2024
17 Jan 2024
Amount
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
Second Depth (1.5 to 3.00m)
Third Depth (3.00 to 4.50m)
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating Each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
2.34.1 Supplying chemical emulsion in sealed containers including delivery as specified . Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
2.35.3.1 Treatment of soil under existing floors using chemical emulsion @ one liter per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration (Excluding cost of Chemical Emulsion).
2.25(a) Supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size).
5.9 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete.
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers.
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts.
5.9.3 Suspended floors, roofs, landings, balconies and access platform.
5.9.7 Stairs, (excluding landings) except spiral-staircases.
5.9.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.33 Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge.“(Note :- Cement content considered in this item is @ 340 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). 5.33.1.2 All works upto plinth level.
5.33.2.2 All works above plinth level upto floor V level.
5.22.6 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
5.22A.6 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
6.1.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand).
22.12 Supplying and applying bituminous solution primer on roof and / or wall surface at 0.24 litre per sqm.
6.4.2 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand).
6.13.2 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
6.15 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
13.1.1 12 mm ceiling Plastering in cement plaster of mix : 1:4 (1 cement: 4 fine sand).
13.7.2 12 mm Wall Plastering cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand).
13.12 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
13.37.1 White washing with lime to give an even shade for New work.
13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer.
13.60.1 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work.
13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).
9.1.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Second class teak wood.
9.5.1 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)Second class teak wood. 9.5.1.1 35 mm thick shutters.
9.5.1.2 30 mm thick shutters.
9.20.1 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
9.72 Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 9.72.1 125x85x5.5 mm (heavy type).
9.72.3 100x85x5.5 mm (heavy type)
9.72.5 75x65x4 mm (heavy type).
9.72.6 75x40x2.5 mm (ordinary type).
9.74 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 9.74.2 200x10 mm
9.75 Providing and fixing bright finished brass door latch with necessary screws etc. complete : 9.75.1 300x16x5 mm
9.76 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
9.82 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
9.84 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
9.85 Providing and fixing bright finished brass casement window fastener with necessary screws etc. complete.
9.129 Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge.
9.79 Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 9.79.2 50mm
9.81 Providing and fixing bright finished brass handles with screws etc. complete: 9.81.1 125mm.
Providing and fixing of Curtains For Windows.
9.147B Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
11.37 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
16.1 Providing & fixing in position Phenol bonded Bamboowood flooring with planks of sizes 14mm thick, minimum 1800mm length and minimum 100 mm wide, in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building Materials & Technology Promotion Council (BMTPC). The flooring shall be fixed with tongue and groove interlocking system, with underlayment of 4mm thick expanded polyethylene foam sheets having density 40kg/cum, over prepared surface with necessary quarter round planks of size 1900mm x 18mm and door reducer of size 1900mm x 44mm, wherever required. The bamboowood planks shall have minimum density of 1000 Kg/cum & minimum Hardness 1000 Kgf. with Eco friendly UV coating, all complete as per direction of the Engineer in-charge.
11.41A.1 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easilyDouble charge vitrified tile polished finish Size of Tile 600 x 600 mm
Providing and laying Carpet Sheet For Flooring.
11.55.1 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
11.24 Extra for pre finished nosing to treads of steps of marble stone.
8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing And Laying Of Wall Stickers On Wall Surfaces.
13.116 Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)
13.48.2 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture.
13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture.
9.48.1 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.
12.17.1 10cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar with bhusha @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow-dung) and covered with machine moulded tile bricks, grouted with cement mortar 1:3 ( 1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat.With machine moulded common burnt clay F.P.S. (non modular) brick tiles of class designation 12.5, conforming to IS 2690.
12.20 Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.
12.22 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
22.6 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured.
11.41A.3 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Size of Tile 600 x 1200 mm.
12.20 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm Each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with12.5 mm thick tapered edge Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3):1996 (Boards with BIS certification mar
10.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
12.1.3 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified 2mm thick flat
10.10 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
25.8 Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.
Providing & Laying On Manglore Tile In Xie Shan Roof.
WATER SUPPLY AND SANITARY ARRANGEMENTS 12.41.2 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
12.42.3.2 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee with door- 110x110x110 mm.
12.42.6.2 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain)-110 mm
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete- 100mm
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 18.17.2 32 mm nominal bore
18.11.1 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 15 mm dia nominal bore
18.49.1 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore.
17.7.1 Providing and fixing wash basin with C.I. brackets,15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.
17.22A Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
17.3.1 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
17.22B Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.
18.74.2 Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 18.74.1 15 mm nominal bore with 30cm length 15 mm nominal bore with 45 cm length.
18.53.1 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore.
18.17.1A Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore.
Providing and fixing on wall / column face unplasticed - PVC soil and waste pipes (type - B) conforming to IS : 13592- 1992 including jointing with seal ring conformation to IS : 5382 leaving 10mm gap for thermal expansion - single socked pipes a) 110 mm dia.
b) 75 mm dia.
Providing and fixing on wall face / column face unplasticised - PVC moulded fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS : 14735 -1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion. a) 110 mm dia, (i) Door bends
(ii) plain bends
(iii) Plain tee
(iv) Door tee
(v) Collars
a) 75 mm dia (i) Door bends
(ii) plain bends
(iii) Plain tee
(iv) Door tee
(v) Collars
Providing and Fixing of PVC floor trap 75 MM
19.4.1.1 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 18.8.2 20 mm nominal dia Pipes.
18.8.3 25 mm nominal dia Pipes.
18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 18.7.4 32 mm nominal dia Pipes
18.34 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
18.65 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
18.22.1 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter.
17.73.2 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms
18.52.1 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore.
17.10.1.1 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board 510x1040 mm bowl depth 250 mm.
ELECTRICAL WORK 1.8 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
1.2 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.1 5/6 amps switch
1.24.3 15/16 amp switch
1.24.4 3 pin 5/6 amp socket outlet
1.24.5 6 pin 15/16 amp socket outlet
1.24.6 Telephone Socket oulet
1.24.7 TV antenna socket outlet
1.22 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 1.22.1 75 mm X 75 mm X 60 mm deep
1.22.2 100 mm X 100 mm X 60 mm deep
1.22.3 150 mm X 75 mm X 60 mm deep
1.22.4 150 mm X 150 mm X 60 mm deep
1.22.5 180 mm X 100 mm X 60 mm
1.22.6 200 mm X 125 mm X 60 mm
1.22.7 200 mm X 150 mm X 60 mm
1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1.21.1 20 mm
1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1.14.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.14.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying, Installation, testing and commissioning of Ceiling Fan including cost of material, labour etc., complete.
Supplying, Installation, testing and commissioning of Exhaust Fan including cost of material, labour etc., complete.
Supplying, Installation, testing and commissioning of 6Watt LED spot light including cost of material, labour etc., complete.
Supplying, Installation, testing and commissioning of 36Watt LED Ceiling light including cost of material, labour etc., complete.
Supplying, Installation, testing and commissioning of 12 Watt LED Ground Burial light including cost of material, labour etc., complete.
Supplying, Installation, testing and commissioning of 36Watt LED Modern Ceiling light including cost of material, labour etc., complete.
Supplying, Installation, testing and commissioning of 6Watt/Meter LED Strip light including cost of material, labour etc., complete.
Supplying, Installation, testing and commissioning of 6Watt LED Brick light including cost of material, labour etc., complete.
Supplying, Installation, testing and commissioning of 6Watt LED Under Water light including cost of material, labour etc., complete.
Supplying, Installation, testing and commissioning of 10 Watt LED Track light including cost of material, labour etc., complete.
Supplying, Installation, testing and commissioning of 16Watt LED Concealed Light Chandelier including cost of material, labour etc., complete.
Supplying, Installation, testing and commissioning of 36Watt LED Concealed Light Chandelier including cost of material, labour etc., complete.
Supplying, Installation, testing and commissioning of 18Watt LED Hanging Ceiling Light including cost of material, labour etc., complete.
Supplying, Installation, testing and commissioning of 15Watt LED Modern Chandelier Light including cost of material, labour etc., complete.
Supplying, Installation, testing and commissioning of 280Watt LED Tiered Candle Chandelier Light including cost of material, labour etc., complete.
Supplying, Installation, testing and commissioning of 20Watt 4 Feet LED Tube Light including cost of material, labour etc., complete.
Supplying, Installation, testing and commissioning of 20Watt LED Projector Light including cost of material, labour etc., complete.
Supplying, Installation, testing and commissioning of 8 Passanger Lift including cost of material, labour etc., complete.
Supplying, Installation, testing and commissioning of 1.5 Tonne A.C 5 Star Rating including cost of material, labour etc., complete.
Supplying, Installation, testing and commissioning of Geyser/Water Heater including cost of material, labour etc., complete.
CCTV WORK Design, Detailing, Approval of Client, Supply, Install, testing & commissioning of entire System of CCTV with the followings Supply, Install, testing & commissioning of 4MP IP Dome Camera with the following specifications: a)1/3" 4.1 MP CMOS, b) Resolution (2560 x 1440) c) 3.6 mm Fixed Lens d) High-Powered IR LEDs e) Voltage 12 V DC f) Picture elements: 2688x1520 g) Protection IP66 h) Operating Temprature degC: -30 TO +60 C
Supply, Install, testing & commissioning of 64 Channel NVR with 4 Sata with the following specifications: a) Up to 12 Megapixels resolution recording b) Support 2-ch HDMI, 2-ch VGA, HMDI1 at up to 4K(3840x2160) resolution c) Up to 64 IP cameras can be connected with 320M incoming bandwidth d) Support H.265/H.264/MPEG4 video formats
Supply, Install, testing & commissioning of 6 TB HDD with the following specifications: a) Interface Tranfer rate Buffer to host : 6GB/s b) Host to/from drive (sustained): 180 MB/s c) Temperature Operating : 0 to 60 deg C, Non-Operating :-40 to 60 deg C
Supply, Install, testing & commissioning of 16 port POE Switch with the following specifications: a) 16X 1000 Mbps PoE ports b) 2 x1000 Mbps combos c) 100 Mbps network access d) Operating Temperature : 0 to 40 deg C e) Voltage -100-240 V DC
Supply, Install, testing & commissioning of 8 port POE Switch with the following specifications: a) 8 X 1000 Mbps PoE ports b) 2 x1000 Mbps combos c) 100 Mbps network access d) Operating Temperature : 0 to 40 deg C e) Voltage -100-240 V DC
Supply, Install, testing & commissioning of 43" LED Smart Television with the following specifications: a) Display Size : 43 inch, Color:Black b) Sreen Type : LED c) Resolution(pixels) : 3840 x 2160 d) Dimensions: 977mm x57mm x80.8mm e) No of HDM1 Port:2, n OF usb Port:1 f)Wifi- Type:802.11ac g)Ethernet RJ45 h) No of speaker:2 i)Sound Technology: Dolby Digital Decoder
Supply, Install, testing & commissioning of OEM PVC Box for Camera Mounting 4x4 ( White ) , Wall Mount/ Ceiling Mount , 22.4 x 21.69 x 10.39 cm ; 680.39 Grams
Supply, Install, testing & commissioning of 12u rack , rack mount hardware , rack mount power strip 6 socket with fuse protection , 1u cantilever tray , 1u cable organizer , with fan and hardare kit
Supply, Install, testing & commissioning of 2U Rack with Power Manager
Supply, Install, testing & commissioning of UPS 2KVA / 72V With inbuilt batteries with the following specifications: a) Output Power Wattage: 1800 W b) Input Voltage: 220 V c) Output Voltage: 230 V d) Input Frequency: 40-70 Hz e) Output Frequency: 50-60 Hz
Supply and Laying of CAT6 cable with pipe and fittings
Supply and Laying of Power cable for POE Switches with pipe and fittings
100 NB, Heavy Class
80 NB, Heavy Class
65 NB, Heavy Class
40 NB, Heavy Class
32 NB, Heavy Class
25 NB, Heavy Class
Supplying, Installing, testing and commissioning of PN 16 lever operated Butterfly valve with required flanges, nuts, bolts etc. complete. 150 NB
Supply, Installation, Testing & Commissioning of 150dia Flow Switches with two NO and two NC contacts with necessary nipple & other fittings
Supply ,Installation, Testing & Commissioning of standard response Glass bulb sprinkler Pendent type rated 68 Deg. C.K-80
Supply ,Installation, Testing & Commissioning of standard response Glass bulb sprinkler Upright type rated 68 Deg. C.K-80
Supply ,Installation, Testing & Commissioning of standard response Glass bulb sprinkler Side Wall type rated 68 Deg. C.K-80
Supply, Installation, Testing & Commissioning of Dial type pressure guageIndustrial type) with necessary nipple & other fittings. 150 NB
Supply, Installation, Testing & Commissioning of 25mm Ball valve with necessary nipple & other fittings
Supply Installation, Testing & Commissioning of Flexible Hose of Minimum 1500mm in length with the required mounting arrangment
Supply Installation, Testing & Commissioning of Alarm Gong VALVE 150DIA As Per Complete setup with Specification
Internal Hydrant Supply, Erection, Testing and Commissioning of above ground piping carried out of MS class C Heavy duty pipe as per IS : 1239 for pipes up to 150mm NB and as per IS : 3589 with a wall thickness of 6.35mm for pipes 200mm NB and above together with fittings, valves and accessories as under : pipe grade shall be Fe330.Work will include all structural supports, painting for the above ground piping with one coat of primer and two coat of enamel paint of approved colour. Work will include cleaning of pipe, degreasing, etc. 150mm nominal dia (Sprinkler Raiser)
100mm nominal dia
50mm nominal dia (Drain Raiser)
80mm nominal dia
25mm nominal dia
Supplying, Installing, testing and commissioning of PN 16 lever operated Butterfly valve with required flanges, nuts, bolts etc. complete. 150mm nominal dia
100mm nominal dia
50mm nominal dia
Supplying, installing, testing and commissioning of Internal Hydrant System comprising of ; Single headed GM hydrant valve as per IS: 5290 (Type A). The valves should be complete with hand wheels, quick coupling connections, springs and blank caps.
2 lengths of 15 M long, 63mm dia RRL hose with couplings and Hoses shall be rolled & hug tosuitable M.S. structural support fixed inside the Fire duct wall.RRL Hose as per IS: 636.
1 no. SS branch pipe with nozzle, As per IS: 903
M.S. cabinet - 18 Gauge with powder coated finish of 750mm x 600mm x 250mm in size and mounted on structural support.
Supply ,installation, testing and commissioning of Fire Hose Reel (as per ISI) wall mounted, swinging type18 SWG MS sheet, fitted with 19 mm dia x 36 M long, high pressure hose with 5 mm outlet GM nozzle with shut off valve (IS: 884-1969)includes Gate valve. and chrome plated nozzle with all necessary fixing materials complete.
Supplying and fixing approved make 25mm dia.automatic air release valve with ball valve, unions etc. complete.
Supplying, fabricating, structural steel supports such as MS channels, angles, flats, rods as required at site with anchor fasteners, clamps, threaded rods, nuts, bolts, washers etc. complete with painting for pipe support.
PUMP ROOM Supply, Installation, Testing & Commissioning of Diesel Engine driven horizontal end suction pump capable to deliver 2280LPM (137m3hr) @ 88Mtrs head. Including controller, complete with Diesel Engine with following Accessories. Diesel Engine Controller, Exhaust Pipe with insulation, Diesel oil Tank with piping, Battery with terminals, Cooling water piping. The rate shall include pressure guage, pressure switch, valves and all accessories.
Supply, Installation, Testing & Commissioning of electrical motor driven sprinkler pump of horizontal end suction pump capable to deliver 2280LPM (137m3hr) @ 88Mtrs head. head The pump shall be coupled to TEFC motor of suitable HP with speed of 2900 RPM and complete set shall mounted on common MS base frame. The rate include pressure guage, pressure switch, valves and all accessories. (HYDRANT ONLY)
Supply, Installation, Testing & Commissioning of electrical motor driven vertical in line Jockey pump of 20.8 cum/hr/335Lpm @ 88Mtrs head. The pump shall be coupled to TEFC motor of suitable speed of 2900 RPM and complete set shall mounted on common MS base frame. The rate include pressure guage, pressure switch, valves and all accessories.
Supply, Erection, Testing and Commissioning of the following size PVC insulated and PVC sheathed / XLPE Power cable of 1.1KV grade FRLS Aluminium / Copper conductor armoured / unarmoured cables. The cables shall be laying on the cable tray and partially laid on wall / ceiling with suitable clamps & necessary fixing accessories etc. as required. Rate shall inclusive of Double compression cable gland and suitable Copper crimping sockets/lugs, crimping paste, sleeves, ferrules etc., as required. 3.5C x 120 sq.mm Aluminium.
4 C x 16 Sqmm. Aluminium
12 C x 1.5 Sqmm. Copper
2 C x 1.5 Sqmm. Copper
3 C x 1.5 Sqmm. Copper
14C x 2.5 Sqmm. Copper Armoured Cable for Diesel Pump
2 C x 2.5 Sqmm. Copper Armoured Cable for instrumentations
1R x 4 Core 25 Sq.mm PVC Copper Armoured Cable for Jockey Pump
Supplying and fixing of perforated G.I.sheet cable tray with neccessory angle iron suspension supports, anchor fasteners etc. complete. Maximum height of suspension shall not exceed 500 mm. 300mm x 50mm x 2.0mm
150mm x 50mm x 2.0mm
100mm x 50mm x 2.0mm
G.I. Earthing strips of , strip shall be run on floor / ceiling / walls, from the equipment to the nearest Earth pit with neccessory accessories as required. ( Earth pit shall be executed by other agencies). 25mm x 3mm thick
50mm x 6mm thick
80gauge strip
Supplying, installing, testing and commissioning of G.I Pipes confirming to IS 1239, with specials such as Tees, elbows, flanges. Including cutting, Painting,Welding, fixing in / on walls, ceiling by using suitable supports etc, as per drawings. 250mm nominal dia
200mm nominal dia
Supplying, installing, testing and commissioning of Heavy grade G.I. Pipes confirming to IS :1239 part - I with butt welded specials confirming to IS:1239 part - II, such as Tees, elbows, check nuts, unions, flanges, nipplesetc. Including cutting,painting Welding, fixing in / on walls, ceiling by using suitable supports, including pipes travelling under ground etc, as per drawings. 200mmnominal dia
150mm nominal dia
100mm nominal dia
80mm nominal dia
50mm nominal dia
25mm nominal dia
Exhuast pipe for Diesel engine of with mineral wool insulation with aluminum sheet.- M.S. 'B' class pipe 150 mm dia
Exhuast pipe for Diesel engine 150mdia
Supplying, installing, testing and commissioning of C.I. Non-return Valve type with required flanges, nuts, bolts and gaskets etc. complete. 250 mm nominal dia
200 mm nominal dia
150 mm nominal dia
80 mm nominal dia
Supplying, fabricating, structural steel supports such as MS channels, angles, flats, rods as required at site with anchor fasteners, clamps, threaded rods, nuts, bolts, washers etc. complete with painting.
Supplying, Installing, testing and commissioning CI Butterfly valves/Gate Valve( PN 20) steam rising operated type with required flanges, nuts, bolts etc. complete. 250mm nominal dia
200mm nominal dia
150mm nominal dia
100mm nominal dia
80mm nominal dia
50mm nominal dia
Supplying, installing, testing and commissioning of Gun metal chrome finished Ball valves with fittings of screwed end type. 25mm dia.
15mm dia
Supplying, installing, testing and commissioning of C. I. Flanged Y-TYPE valve Strainer with SS mesh,suitable flanges, nuts, bolts, gaskets etc. complete.(PN 20) 250 NB
Supply, Installation, Testing & Commissioning of pressure switch With Required Ball Valve As per Specification
Supply, Installation, Testing & Commissioning of Flow meter (150mm) size with required flanges, nuts, bolts etc. complete.
Supply, Installation, Testing & Commissioning of Dial type pressure guage (100mm Industrial type) with Ball Valve necessary nipple & other fittings
Supply, fixing, testing and commissioning of M.S. material Air Vessel Tank of size 300 mm dia x 1000 mm long x 6 mm thickness with necessary inlet & outlet flange, 20 NB brass air release valve, 25 NB drain valve with supporting leg and etc., complete as per detailed specification.
Supply, fixing, Priming tank 'Sintex' 1000 Lts. Capacity complete with25nb float valve, level indicator,Drain valve, etc
Supply, Erection, Testing and Commissioning of Metallic-Rubber bellow flexible connections of suitable pressure rating to be installed at equipments suction and discharge.with necessary fittings and accessories like flanges, GI bolts, nuts & washers, painting etc. 250 NB
Supply, Installation, Testing & Commissioning of Puddle Flange aAs Per specification 200dia
Extinguisher Supply of Hand held Fire Extinguisher - CO2 - 4.5 Kg with suitable Metal Floor stand MS fabricated painted in black colour
Supply of Hand held Fire Extinguisher - ABC Powder - 6 Kg with suitable Metal Floor stand MS fabricated painted in black colour
Supply of Wet Chemical Poweder K-Type Fire Extinguisher - 6 Kg with suitable Metal Floor stand MS fabricated painted in black colour
Exit signage FIRE EXIT (400mmx150mm double side)
FIRE EXTINGUISHER (100mmx150mm single side)
MANUAL CALL POINT (100mmx150mm single side)
EVACUATION PLAN with AUTO GLOW in A2
ELECTRICAL PANEL BOARD AND CABELS 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.10.3 Group C
1.11 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
1.12 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
1.14 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.14.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
1.14.10 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
1.14.11 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1.17.3 A. 3x1.5 sq. mm
1.17.12 3x2.5 sq.mm
1.17.13 4x2.5 sq.mm
1.17.21 3x4 sq.mm
1.19 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
1.20 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 1.20.1 20 mm
1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1.21.1 20 mm
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.1 5/6 A switch
1.24.3 15/16 A switch
1.24.4 3 pin 5/6 A socket outlet
1.24.5 6 pin 15/16 A socket outlet
1.24.7 TV antenna socket outlet
1.24.8 Bell push
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.27 Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required. 1.27.1 1 or 2 Module (75mmX75mm)
1.27.2 3 Module (100mmX75mm)
1.27.3 4 Module (125mmX75mm)
1.27.4 6 Module (200mmX75mm)
1.27.5 8 Module (125mmX125mm)
1.27.6 12 Module (200mmX150mm)
1.31 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
1.32 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1.34 Supplying and fixing brass batten/ angle holder including connection etc. as required.
1.35 Installation .Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing up to two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
1.36 Supplying and fixing stiff pendent with 300 mm long, 20 mm dia X 1.6 mm thick steel conduit, aluminium cast back plate and brass holder complete, including wiring the down rod with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and painting etc. as required.
1.38 Supplying and fixing call bell/ buzzer suitable for single phase, V, complete as required.
1.41 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
1.42 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc., including supplying and fixing ball and socket arrangement, 2 Nos. down rods of 20 mm dia X 1.6 mm thick steel conduit up to 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
1.44 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1.49 Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
1.50 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1.50.1 Up to 450 mm sweep
1.51 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
1.55 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. A. 1.55.3 Group C
1.57 Supplying & fixing suitable size Gl box with modular plate and cover in fronton surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Sub-Head : MCCB, MCB & OB'S 2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator). 2.3.2 8 way , Double door
2.3.3 12 way , Double door
2.3.4 16 way, Double door
2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator). 2.4.2 6 way (4 + 18), Double door
2.4.3 8 way (4 + 24), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 2.5.2 8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 Single pole
2.10.3 Double pole
2.10.4 Triple pole
2.10.5 Triple pole and neutral
2.11 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.12 Supplying and fixing following rating, double pole, the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.12.1 40 A
2.13 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.13.2 63 A
2.15 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.15.3 63 A
2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
2.17 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
2.18 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
2.21 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
2.23 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. 2.23.2 For 8 way, Double door SPN MCBDB
2.23.3 For 10 way, Double door SPN MCBDB
2.23.4 For 14 way, Double door SPN MCBDB
2.24 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. 2.24.2 For 6 way, Double door TPN MCBDB
2.24.3 For 8 way, Double door TPN MCBDB
2.25 Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
Sub-Head : CABLE TRAYS 4.1 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 4.1.1 100 mm width X 50 mm depth X 1.6 mm thickness
4.1.4 300 mm width X 50 mm depth X 1.6 mm thickness
4.1.6 450 mm width X 50 mm depth X 2.0 mm thickness
4.1.14 600 mm width X 75 mm depth X 2.0 mm thickness
4.2 Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 4.2.1 100 mm width X 50 mm depth X 1.6 mm thickness
4.2.4 300 mm width X 50 mm depth X 1.6 mm thickness
4.2.6 450 mm width X 50 mm depth X 2.0 mm thickness
4.3 Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 4.3.4 300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
4.4 Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 4.4.6 450 mm width X 50 mm depth X 2.0 mm thickness.
4.4.14 600 mm width X 75 mm depth X 2.0 mm thickness
4.5 Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 4.5.4 300 mm width X 50 mm depth X 1.6 mm thickness
4.5.6 450 mm width X 50 mm depth X 2.0 mm thickness
4.5.14 600 mm width X 75 mm depth X 2.0 mm thickness
4.6 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.l. suspenders including G.l. bolts & nuts, etc. as required. 4.6.6. 450 mm width X 50 mm depth X 2.0 mm thickness
4.6.14 600 mm width X 75 mm depth X 2.0 mm thickness
4.6.15 750 mm width X 75 mm depth X 2.0 mm thickness
4.7 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (Galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.l. suspenders including G.l. bolts & nuts, etc. as required. 4.7.6 450 mm width X 50 mm depth X 2.0 mm thickness
4.7.14 600 mm width X 75 mm depth X 2.0 mm thickness
4.7.15 750 mm width X 75 mm depth X 2.0 mm thickness
4.8 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (Galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.l. suspenders including G.l. bolts & nuts, etc. as required. 4.8.14 600 mm width X 75 mm depth X 2.0 mm thickness
4.8.15 750 mm width X 75 mm depth X 2.0 mm thickness
4.9 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member" (Galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.l. suspenders including G.l. bolts & nuts, etc as required. 4.9.14 600 mm width X 75 mm depth X 2.0 mm thickness
4.9.15 750 mm width X 75 mm depth X 2.0 mm thickness
Sub-Head : EARTHING 5.2 Earthing with G.l. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
5.4 Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.7 Supplying and laying 6 SWG G.l. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with Gl thimble etc. as required.
5.9 Supplying and laying 25 mm X 5 mm G.l. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.l. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.l. nut bolt & spring washer spaced at 50mm)
5.11 Providing and fixing 25 mm X 5 mm G.l. strip in 40 mm dia G.l. pipe from earth electrode including connection with G.l. nut, bolt, spring, washer excavation and re-filling etc. as required.
5.13 Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.l. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
5.15 Providing and fixing 25 mm X 5 mm G.l. strip on surface or in recess for connections etc. as required.
5.16 Providing and fixing 6 SWG dia G.l. wire on surface or in recess for loop earthing as required.
5.19 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/cable as required.
Sub-Head : Ceiling Fan with BLDC Motor 19.1 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
LED LIGHT FITTINGS 1) All light fittings and fans shall be got approved by Client before supply at site. 2) All the light fittings should have the following features a) THD shall be less than 10% b) PF should be 0.9 or better c) RoHS complaince d) LED lamps should have a luminous efficacy of 90lumens/Watt e) UGR should be 19 or less f) For indoor lights CRI shall be greater than 80 and that of Outdoor lights greater than 70. g) All indoor luminaries should have passed "Photo Biological Safety Standards Test" 3) IES files of all the luminaries shall be submitted 4) Corelated Colour temperature (CCT) mentioned against each fittings are indicative only and the exact CCT of each fitting shall be finalised before supply in consultation with Engineer-in-Charge / Authorities according to the application) Supply and installation of the following LED Light fittings / Fans with required fixing supports, etc., Surface/suspended type 4Feet Long 20Watts LED Light fitting with Polycarbonate / Metallic body, operating voltage 150-270V, IP-20 with LED Batten type light fitting
Surface/suspended type 4Feet Long 40Watts LED Light fitting with Polycarbonate / Metallic body, operating voltage 150-270V, IP-20 with LED Batten type light fitting
LED recess / surface mounted type Luminaire 2'x2' size up to 36Watts (max), capable of delivering 3200 lumens (min) output
Surface / Recess mounting type LED Integrated Down Lighter with maximum power input of 9Watts and with Lumens output as per standards
Surface / Recess mounting type LED Integrated Down Lighter with maximum power input of 12Watts / 15Watts and with Lumens output as per standards
Surface / Recess mounting type LED Integrated Down Lighter with maximum power input of 22Watts and with Lumens output as per standards
10Watts LED Up-Down IP65 rated light fitting with fixing supports
12Watts / 15Watts LED Wall mounted type Light ftting
10Watts IP65 rated LED Bulk head light fitting
Supply, Installation, testing and comissioning of medium duty exhaust fan 900-1350 rpm, 300mm, in metal body in the existing opening, including louver shutter, making the hole to suit the size of the above fan, making good the damage, connection, etc., as required
SWAPAN LODH ROY
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid