Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹22.2 L
EMD Value
₹44,420
Closing Date
10 Oct 2022, 4:00 pmClosed
Executive Engineer STD Ganderbal
Office of the Executive Engineer STD Ganderbal
33KV Line Bay, 33KV Transformer Bay and Power Transformer for Receiving Station Saloora Under Capex Budget
2022_PDD_188844_1
STD GBL 26 OF 2022-23 DATED 17-09-2022
Open Tender
Electrical Works
Item Rate
30 days
Saloor Ganderbal
REFER SBD
10 documents required · 10 mandatory
₹1,000
Yes
Office of the Executive Engineer STD Ganderbal
₹44,420
Yes
29 Oct 2022
17 Sept 2022
11 Oct 2022
17 Sept 2022
10 Oct 2022
21 Sept 2022
17 Sept 2022 - 10 Oct 2022
Amount
33KV Line Bay, 33KV Transformer Bay and Power Transformer for Receiving Station Saloora
Loading, Transportation, installation and commisioning of 33 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type) (*to be lifted from the Divisonal Store Safapora) along with providing and fixing of allied accessories and heavy duty pad clamps if required
SITC of 33 kV Isolator without Earthing Blade with allied accessories and pad clamps (36kV,1250A, Outdoor, 3 poles, 25 kA) with multi fingered female contacts with tin coated contacts and Blate tips.
SITC of 33 kV Isolator with Earthing Blade with allied accessories and pad clamps (36kV,1250A, Outdoor, 3 poles, 25 kA) with multi fingered female contacts with tin coated contacts, The isolator is to be provided a locking arrangement for un-authorized operation.
Loading, Transportation, installation and commisioning of 33 kV Current Transformer (*to be lifted from the Divisonal Store Safapora) along with providing of allied accessories if required
SITC of 33KV/110V PT dead tank oil type with to single phase mounted brass clamps with and as per DDUGJY specifications.
SITC of 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Porclean type) gap less including its clamps and base insulators complete.
Loading, Transportation, installation and commisioning of 33kV C&R Panel along with O/C, E/F relays, mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps with RS-485 port, DLMS Compliant with RS-485 port (*to be lifted from the Divisonal Store Safapora) and providing and fixing of of extra terminals for remote switching of switchgear
SITC of 600/300/5A-5A 11kV dead tank type Neutral Current Transformer for Transformer Neutral with flow meter attachment including earthing with GI 50x6mm Strip and its terminations complete
SITC of 33/0.433kV, 100KVA 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, Copper wound, and with LV Cable Box having detachable Aluminium Gland plate to be mounted on 33KV Gantry structure and firmly fixed with angles and channel iron. the Job includes the mounting of transformer at 33kv Gantry beams.
SITC of Junction Boxes for CT and PT of size 1.5x1.5 ft 12 swg sheet metal body with powder coated with weather proof chamber IP-67 protected having Din rail terminals mounted termination contacts of 36 Numbers as per REC standard
SITC of 33 kV Horn Gap Fuse Set 3 Phase 100A in fibre rod with allied accessories complete
SITC of 120 mm² 4-Core Cable,1.1kV Grade, PVC Insulated Armoured with aluminium Stranded Conductor FRLS type including fixing of lugs at cable terminations ends.
SITC of 160A MCCB 36KA with Kiosk box IP-65 Protected with inbuilt bus bars with cable gland cut outs with door and clamps.
Installation and commisioning of 33/11kV, ONAN, Copper wound, Out-door Type, conventional 6.3MVA Power Transformer, Oil Filled with OLTC and all accessories including HT and LT Terminal connections (Trasnformer to be provided by the department)
Testing installation commissioning of RTCC pannel along with allied accessories (Provided by Department)
Supply & Installation of 33 kV Post Insulator Polymer 36kV,170kV Impulse, creepage distance 1224m, as per DDUGJY spec.s
Supply & Installation of 33KV Polymer Disc insulator sets with 70KN and as per DDUGJY Specifications.
Providing & fixing of heavy duty Pressure di-cast aluminium 630A T-clamps suitable for 0.15 ACSR Conductor having 8 no,'s GI bolts of 19mm thick.
Providing & fixing of heavy duty Pressure di-cast aluminium 630A PG-clamps suitable for 0.15 ACSR Conductor having GI bolts of 19mm thick.
Supply & laying of multi core 12-core 2.5 sq.mm Copper Armoured control cables with suitable brass/PVC glands for each cable including codding, thimbling and labelling of each cable interconnection and terminations
Supply & laying of multi core 8-core 2.5 sq.mm Copper Armoured control cables with suitable brass/PVC glands for each cable including codding, thimbling and labelling of each cable interconnection and terminations
Supply & laying of multi core 4-core 2.5 sq.mm Copper Armoured control cables with suitable brass/PVC glands for each cable including codding, thimbling and labelling of each cable interconnection and terminations
Supply & laying of multi core 2-core 2.5 sq.mm Copper Armoured control cables with suitable brass/PVC glands for each cable including codding, thimbling and labelling of each cable interconnection and terminations
Providing & fixing of 75x75x6mm GI iron Angles of sorts including cutting, bending, drilling, welding etc complete modification as per site requirement.
Providing & fixing of 65x65x6mm GI iron Angle of sorts including cutting, bending, drilling, welding etc complete modification as per site requirement.
Providing & fixing of 50x50x6mm GI iron Angles of sorts including cutting, bending, drilling, welding etc complete modification as per site requirement.
Providing & fixing of 100x50x6mm GI Channel iron of sorts including cutting, bending, drilling, welding etc complete modification as per site requirement.
Providing & fixing of Flat iron 50x6mm of sorts including cutting, bending, drilling, welding etc complete modification as per site requirement.
Providing & fixing of GI Nuts and bolts with washers of sorts
Providing and laying of HDPE Pipe 180mm dia for laying of auxilliary cable from transformer to ACDB, Charger, Battery bank and DCDP pannel underground by way of excavation and backfilling complete job
Control wiring including commisssioning, thimbling, furel codding, cable glanding and relay testing of each pannel/control circuits from approved agency with reports. Complete job
Providing and laying of 0.15 ACSR aluminium conductor at 33kv yard for connecting of 33kv gantry and equipment including cutting, connecting of jumpers, tighting, stringing etc complete job.
Providing and fixing of 10-36Ka 440v-650 VAC/DC Surge absorbers 3-phase with neutral to be installed at LT terminal box of auxilliary supply/ACDB on din rail channel inlcuding its Separate chemical earthing electrode type 8 -10 feet long with ashgel/betonite chemical and earthing with 10. sq.mm flexible copper cable from earthing point to surge absorbers 1x1 feet inspection plate. complete job
Providing of FOS Search lights LED type 10 Watt Protector with dual Charging with mains 220v and solar 6 vdc plate based having 1km range with allied accessories complete
Providing of Bolt cutter of Taparia make BC-42 with allied accessories.
Providing and fixing of Aluminium Bus Bars for Transformer terminals of suitable size with color codding Heat shrink sleeves covered including drilling, welding, etc complete modification as per requirement to be fixed on LV side of Power Transformer and Neutral Ct.
M/S RB POWER SOLOTIONS
KAPH TECH CONSULTANCY (P) Ltd.
stage.html
html • 0.03 MB
tech_bid_open.pdf
PDF • 0.44 MB
tech_eval.pdf
PDF • 0.45 MB
fin_bid_open.pdf
PDF • 0.60 MB
boq_comp_chart.xlsx
xlsx • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .