Revamping of PA and FAS of CRI and CRC building ACTREC
2026_TMC_903269_1
ATA/ET-90 /Revamping of PA and FAS System
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
120 days
ACTREC, Kharghar
As per tender terms and conditions
5 documents required · 5 mandatory
₹0
₹1.1 L
ACTREC, Kharghar
20 Mar 2026
20 Mar 2026
7 Apr 2026
20 Mar 2026
6 Apr 2026
20 Mar 2026
20 Mar 2026 - 26 Mar 2026
27 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1AUTOMATIC DETECTION AND ALARM SYSTEM | |||||
| 2Panel | |||||
| 3Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting not less than 250 devices and detectors per loop, with on-board LCD alphanumeric backlit display suitable for minimum 80 characters, operating at 230 V 50 Hz - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 minutes in alarm condition, The panel shall have suitable provision for network connectivity & compatible for third party integration(Open Protocol to communicate) via a MODBUS/BACNET interface etc. conforming to IS 15908:2021, IS 2189: 2008, NFPA-72, EN 54 / VdS/FM & UL 864(10th edition) with 3 years replacement warranty and inclusive of lifetime software license validity , as per specification noFF-AFAS/CP. | |||||
| 4Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. | |||||
| 5Supplying, installation, testing & commissioning of fault isolator complete with base as required. | |||||
| 6Supplying, installing, testing and commissioning of addressable fire monitor module for flow switches, Panic Bars & other Third Party Inputs. The monitor module shall monitor potential free contacts. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the health status of the device complete as required. Module shall conforming to IS 5051 Part 2 (Sec 1 to 3) : 1982 Reed relays, EN 54/VdS / UL & FM approved with 3 years equipment replacement warranty, as per specification no FF-AFAS/MM | |||||
| 7Supplying, installation, testing & commissioning of addressable fire control module complete as required. | |||||
| 8Supplying, installing, testing and commissioning of addressable fire control/ relay module for AHU, Access Control, Lifts, Staircase Pressurization, Fire Suppression & other Third Party Outputs etc., Module shall conforming to IS 5051 Part 2 (Sec 1 to 3) : 1982 reed relays / EN 54/VdS / UL & FM approved with 3 years equipment replacement warranty, as per specification no FFAFAS/CRM-FCM | |||||
| 9Supplying, installation, testing & commissioning of addressable manual call point complete as required. | |||||
| 10Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. | |||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.78 MB
BOQ_949428.xls
BOQ • 0.31 MB
AnnexureForm.xls
Additional Documents • 0.12 MB
TD.pdf
Tender Documents • 2.07 MB
PreBidLink.pdf
PDF • 0.22 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .