| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC 708 PREM NAGAR KARNAL HARYANA 132001 | KARNAL | KARNAL | HARYANA | 132001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹20.2 L+₹1.8 L (9.98%)Rejected-Finance AMAR NIWAS RA 288 GANDHI CHOWK SADAR BAZAR KARNAL | KARNAL | KARNAL | HARYANA | L2 | Rejected-Finance Highest | |
| 3 | L3₹21.2 L+₹2.8 L (15.2%)Rejected-Finance KHASRA NO 183 10 SHYAM VIHAR HISAR HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L3 | Rejected-Finance Highest | |
| 4 | L4₹21.3 L+₹3.0 L (16.1%)Rejected-Finance | L4 | Rejected-Finance Highest |
Tender Value
₹19.8 L
EMD Value
₹39,540
Closing Date
5 Nov 2020, 5:00 pmClosed
Ritesh Nandal
Executive Engineer, Electrical Division, PWD B and R Br., Ambala Cantt.
Const. of Govt. Industrial Training Institute (ITI) at Shahabad in Distt. Kurukshetra (Pdg. 250 KVA Elect. Sub Station).
2020_HRY_148790_1
PWD/Elect-KNL/Elect-AMB/110060
Open Tender
Construction Works
Works
120 days
Ambala Cantt
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
E.E., Elect. Division PWD B and R Br.,
₹39,540
11 Jan 2021
26 Oct 2020
6 Nov 2020
26 Oct 2020
5 Nov 2020
26 Oct 2020
Amount
( c )Moulded case Circuit breakers. Supply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections. 100 amp.to 220 amp.415 V,10 KA 3-phase. HSR No 31.12 c (ii)
Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suiteble size of rag bolts with cement concrete ,duly painted with three coats of approved paint including one coat of red oxide. Size 50 mm x 50 mm x 6 mm. HSR No 31.13(I)
(P) Pipe Laying. Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. Galvanised iron pipe 65 mm dia on flushed. HSR No 31.21 (xiv)
Supply and erection of PVC pipe of 6 kg. pressure laid 1 metre below ground level complete including digging refilling of the trench with jointing etc. PVC pipe 120 mm dia. HSR No 31.21(xxx) (a)
(Q) Earthing Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required . HSR No 31.22(i)
Extra for using salt and charcoal / coke for pipe earth electrode as required. HSR No 31.22(ii)
Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as equired. HSR No 31.22(iii)
Earthing with tinned copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) comlete as equired. HSR No 31.22(iv)
Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode. HSR No 31.22(v)
Pdg. and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required . HSR No 31.22(x)
Pdg. and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required with all labour and material. HSR No 31.22(xiv)
Pdg. and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode as required . HSR No 31.22(xi)
Pdg. and fixing 25 mm x 5 mm GI strip on surface or in recess for connections etc. as required with all labour and material. HSR No 31.22(xv)
Supply and erection of 20 mm x 3 mm thick G.I. tape fixed with suitable G.I. stapples of same size. HSR No 31.22(xix)
Pdg. and fixing 4.00 mm dia G.I.wire on surface or in recess for loop earthing as required . HSR No 31.22(xvi)
Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections . 95 Sq. mm 3.5 Core Cable . HSR No 31.26 (xxix) Ard.
120 Sq. mm 3.5 Core Cable . HSR No 31.26 (xxx) Ard.
240 Sq. mm 3.5 Core Cable . HSR No 31.26 (xxxiii) Ard.
Supply and erection of suitable compression type brass cable glands for underground Cable. 120 Sqmm to 185 Sqmm Cable 3 to 3.5 Core HSR No 31.28 (v)
240 Sqmm Cable 3 to 3.5 Core . HSR No 31.28 (vi)
( T ) Street Light. Supply and erection of prestressed cement concrete pole as per IS : 1678-1960. 9 metres long 105 mm x 115 mm at top and 105 mm x 315 mm at bottom with working load of 200 Kg. burried 1.80 m in ground. HSR No 31.30 (VI) (ii)
(X) Miscellaneous . Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer-in-charge of the work. 120 sqmm . HSR No 31.35 (ix) (j)
240 sqmm . HSR No 31.35 (iX) (m)
Supply and erection of cable route marker made of 50 cm long 10 mm dia M.S.rod welded / revitted at the top with 10 cm. Dia 5 mm thick G.I.plate inscribed with `cable' world on it , having a cross arm 30 cm. long of the same dia welded at the bottom , in existing trench 45 cm. below ground level . HSR No 31.35 (xi)
Supply, Installation, Testing and Commissioning of Wall/ free standing flooor mounting dust & vermin proof compartmentalized cubical panel made out of 2 mm thick CRCA sheet, required hardware 3 mm thick bakelite sheet provided all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 coat of Zinc/Red oxide primer followed by 2 coats of powder coating in grey or required shade after rinsing. The panel having PU/Neoprene rubber gasket of not less than 3 mm thicness seperate detacable gland plate MS base channel hinged door with inter locking arrangement for equipment/switch wear.Transparent acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar bakelite sheet 3 mm thick for separately cable alley to BBC from switch chamber Extended solid copper bars up to cable cable alleys shall be provided for outgoing connection which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors withdetachable extension type structure. The panel will be complete with control wirring (copper) and fuse protection.(only outer area on all sides shall be measured) HSR No 31.63
Supply and fixing of copper bus bar duly tinned by means of SMC/DMC type insulator high tensile nuts and bolts spring washers fixing to same in existing panel including bending, cutting in required shape and size and insulation with colour coding heat shrinkable PVC insulation complete in all respect. HSR No 31.64
Supply and fixing of rotary handle for on / off operation of existing MCCB in the LT panel including fixing the same in position with all labour and material required to complete the job in all respect. Rotary handle upto 125 A, MCCB HSR No 31.66 (i)
Rotary handle above 125 A, MCCB HSR No 31.66(ii)
S/E of mark double walled corrugated (DWC) HDPE pipe laid 1 Mtr. Below ground level including diging and refilling of earth including cost of suitable size socket cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to entire satisfaction of Engineer- incharge of the work. HDPE Pipe 145/123 outer dia / inner dia. HSR No 31.67(iii)
Supply & erection of Module case circuit breaker single pole / 4 pole on wall/ on existing pedestal including bounding to earth and making necessary connection required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of work. 4 pole MCCB 500 amp HSR No 31.69 viii
S/E of XLPE (E)11 KV HT aluminum conductor armoured cable ISI mark laid in existing pipe /trenches/surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. Size 50mm 3 core HT XLPE cable HSR No 31.71 ii)
Supply and erection of heat shrinkage type end termination jointing kit indoor type of suitable to accommodate 3 core 11 KV XLPE aluminum cable/ ABC cable complete with all the kit contents including earth continuing connection along with 3 nos. crimpling type aluminum lugs of suitable capacity including making joining etc complete in all respect. Suitable for 16 to 50 sqmm 3core XLPE Cable HSR No 31.72 i
Supply and erection of heat shrinkage type end termination jointing kit outdoor type of suitable to accommodate 3 core 11 KV XLPE aluminum cable/ ABC cable complete with all the kit contents including earth continuing connection along with 3 nos. crimpling type aluminum lugs of suitable capacity including making joining etc complete in all respect. Suitable for 16 to 50 sqmm 3core XLPE Cable HSR No 31.73 i
SITC of 250 KVA, Outdoor type, oil cooled Transformer, 11/0.433 KV, Copper Wound with Off Circuit Tap Changer ( Kirloskar Make ) as per IS 1180, Level-2, complete in all respect upto the entire satisfaction fo Engineer- in Charge of work. Make -Alstom, Bharat Bijlee, CG , Crompton, Voltamp, ABB, Siemens, Schneider. (Only valid approved makes). Rating -250 KVA No Load Voltage Ratio (KV) -11/0.433KV No. of Phase 3 Frequency Cycle 50Hz Type - Oil Cooled Type Cooling ONAN Connection -HV/LV -Delta / Star Vector Group - Dyn -11/IS : 1180 Level 2 Tapings on HV Compensation: +5% to -5% In steps of 2.5% Tempearture Rise ( Winding ) Ambient : Not Exceeding 90Deg C. " OFF Circuit" Tap Changer Altitude upto 1000M above M.S.L Externally Hand Operated Oil Conservator with filling hole & cap plain oil level gauge with min. level marking thermometer pocket 4 Nos. Plain roller Uni- directional Silica Gel Breather 1st filling of oil Drain Cum Filter Valve Rating & Diagram Plate Two Earthing Terminals Lifting Arrangement Explosion vent Air Release Plug Oil Temp. indicator with alarm and trip indicator Double Float Buchloz Relay & Conservator Shut Off valve between Buchloz Relay & Conservator Winding Temp. indicator with alarm & trip contact Complete in all respect NS-1
SITC of LT Capacitor Bank Panel 95KVAR capacity having size 650mm x 1900mm x 500mm made out of 14SWG CRCA sheet for load bearing surfaces & 16SWG for non load bearing surfaces with 2nos. 10 KVAR, 1No. 15 KVAR & 3 Nos. 20KVAR capacity Capacitors alongwith control wiring etc. copmplete in all respect upto the entire satisfaction of Engineer-in-charge of work. Incomer side MCCB 250 A 3P =1No. ROH=1No. SPREADER LINKS =1No. APFC RELAY =1No. MCB SP 2/6A =3Nos. Control Terminal =8Nos. 10 KVAR CAPACITOR FEEDER MCB 32 A TP CAP DUTY =2Nos. CONTACTOR CAP.DUTY. 10 KVAR =2Nos. PUSH BOTTEN =4Nos. ON INDICATION =2Nos. AUTO-MANUAL SWITCH =2Nos. 6 Amp Control MCB SP =2Nos. 15 KVAR CAPACITOR FEEDER MCB 32 A TP CAP DUTY =1No. CONTACTOR CAP.DUTY. 15 KVAR =1No. PUSH BOTTEN =2No. ON INDICATION =1No. AUTO-MANUAL SWITCH =2Nos. 6 Amp Control MCB SP =2Nos. 20 KVAR CAPACITOR FEEDER MCB 63 A TP CAP DUTY =3No. CONTACTOR CAP.DUTY. 20 KVAR = 3Nos. PUSH BOTTEN =6Nos. ON INDICATION =3Nos. AUTO-MANUAL SWITCH =3Nos. 6 Amp Control MCB SP =3Nos. BUS BAR (B) Bus Bar will be of Electrolytic COPPER of size:250A ENCLOSURER ( C) CRCA sheet steel enclosure. Panel will be fabricated with 14SWG CRCA sheet steel for load bearing surfaces and 16SWG for non load bearing surfaces. Tentative Dimensions - 650 X 1900 X 500 MM WIRING (D) Harness for starter & metering, Thimbles, Ferrules, Sleeves, PVC channel, Gourmets, Braided wire for earthing etc HARDWARE (E) (Nuts, Bolts, Spring washers, Door hinges, Door Locks & Key, Lifting hocks, Base channel, C-type Channels, DMC Busbar Insulators etc) ACCESSORIES (F) Danger plate, Feeder detail Inscription plates, Acrylic/Bakelite/Perforated sheet cover for busbar, Door gasket etc. NS-2
S/E of 11KV gang operated switch Rashtriya / Jayshree / BHEL make conforming to IS with latest amendment including suitable size of copper blade erection of same on the existing 'H'pole with the help of 3 Nos. channels of size 75mmx40mmx6mm, 1.8M long fixed with suitable size of MS clamp, nuts and bolts including cost of 6 Nos. 11KV insulator with GI pin, RD fuses and painting with 2 coat of approved paint and one coat of red oxide material required to complete the job in all respect up to entire satisfaction of the Engineer-in-Charge of the works. NS-3
Providing and fixing of 11 KV oil cooled CT/PT :combined unit ratio 20/5 A.0 0.5 (5) VA 5 and PT ratio 11/110 volt AC 0.5 VA / 0 along with ;metering cubicle etc. fixing on H. pole metering cubicle wiring with plate form required to complete the job in all respect upto the entire satisfaction of the engineer it charge of the work. NS-4
S/E of Rubber mat of size 2mX1m & 12 mm thick suitable for 11 KV complete in all respect upto the entire satisfaction of the engineer it charge of the work. NS-5
Supply & Erection MS bucket stand which including cost of 6 nos. buckets of 9 liter capacity with sand filling including cost of welding & painting of complete stand & buckets with one coat of red oxide and two coats of approved paint of red colour with all labour & petty material to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of work. NS-6
S/E of fire extinguiher ISI marked ABC type 6 kg. capacity powder base with square grip gavle duly erected/hung on wall with hook including the cost of hook, screw etc. with all the all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works. (make- Safex/Ceasefire/Minimax) NS-7
Pdg. & Fixing of Wire Mesh Jali around the Transformer of size 4' x 8' made out of 75 x 25x 3.25 mm Jali fixed with angle iron frame made out of MS Angle 50 x 50 x 6 mm support of MS flat 50 x 6 mm and fixed in CC block 1:2:4 incliding cutting, welding etc. as per drawing complete in all respect upto the entire satisfaction of the Engineer - in - charge. NS-8
Supply and erection of MS flat 50x6mm including cutting bending to the required shape drilling hole carriage Painting loading unloading complete in all respect upto the entire satisfaction of Engineer-in-charge of work NS-9
Supply and erection of MS channel 100x50x6mm including cutting bending to the required shape drilling hole carriage Painting loading unloading complete in all respect upto the entire satisfaction of Engineer-in-charge of work. NS-10
DSR ITEMS Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. DSR No. 13.1
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per,metre) pole top bracket/ cross arm for single 11 KV over head, line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required. DSR No. 13.2
Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required DSR No. 13.6
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. DSR No. 13.1
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. DSR No. 13.13
Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required (excluding reinforcement). DSR No. 14.1
Som Nath Contractor
M/s JSB Enterprises
Ecs Engineering Chd. Pvt. Ltd.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .