| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67.1 LAccepted-AOC | L1 | Accepted-AOC Eligible due to Low quoted bidder | |
| 2 | L2₹67.6 L+₹50,651.51 (0.75%)Rejected-Finance | L2 | Rejected-Finance Not Eligible | |
| 3 | L3₹68.3 L+₹1.1 L (1.71%)Rejected-Finance | L3 | Rejected-Finance Not Eligible | |
| 4 | L4₹72.9 L+₹5.8 L (8.62%)Rejected-Finance | L4 | Rejected-Finance Not Eligible | |
| 5 | L5₹76.4 L+₹9.3 L (13.9%)Rejected-Finance JAIPUR RAJASTHAN 302021 INDIA UDYAM RJ 17 0037439 02AAVFB5117E1ZQ B R | JAIPUR | RAJASTHAN | 302021 | L5 | Rejected-Finance Not Eligible |
Tender Value
Refer Docs
Closing Date
24 Dec 2021, 6:00 pmClosed
Asstt. Gen. Manager (E-C)
New Operational Building, NSCBI Airport, Kolkata-52.
Construction of Boundary Wall for balance portion and raising of Boundary wall over existing Boundary wall at Bagjola at NSCBI Airport, Kolkata
2021_AAI_98199_1
AAI/KOL/E-C/KOL/NIT-07/2021-22
Open Tender
Civil Works
Item Rate
183 days
Kolkata
Please refer Tender documents.
17 documents required · 17 mandatory
₹1,180
Exempted
8 Mar 2022
14 Dec 2021
27 Dec 2021
15 Dec 2021
24 Dec 2021
15 Dec 2021
15 Dec 2021 - 17 Dec 2021
Amount
Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like.
Drum Sheet Walling 1.5m (av.) high on Eucalyptus bullah piling of 10 cm dia. and 3.00m long driven 1.5m (av.) below G.L. and 50cm centre to centre including fitting fixing 3 nos. of half bullah pieces (from 10 cm dia) and drum(empty bitumen) sheet (approved condition) of height 1.5m , cutting and straightening drum sheet (each joint must have lap length of min.50mm) including cost of necessary nails, bolts, nuts etc. and providing 2 to 3m long half bullah ties of 10cm dia. @ 2.25 m centre to centre fixed with 10 cm dia. bullah posts driven 1.5m below G.L. including cost of all materials and one coat of coal tarring to all bullah etc. complete as per direction.(Refer Sketch enclosed under Drawing section in Tender document )
Removing sludge/mud and other submerged debris by mechanical means (Hydraulic excavator)/manual means including getting out and disposal of excavated earth lead upto 50m, as directed by Engineer-in-charge. .(Refer Sketch enclosed under Drawing section in Tender document )
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand)
12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand).
15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand)
Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) : 450 mm dia piles
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.Initial test (Test Load 2.5 times the Safe capacity)
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge /Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. Routine test (Test Load 1.5 times the Safe capacity)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removalof form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Providing and fixing uPVC pipe of 75 mm dia and 350 mm length (working pressure 4 kg / cm 2) for making weep hole of boundary wall, Pipe to be fixed with cement mortar of 1:4 (1 Cement:4 Coarse sand) as per the direction of Engineer-in-charge.
Lettering with black enamel paint of approved brand and manufacture. (Lettering to be made by cutting stencil and painted on the wall so that uniformity can be maintained on whole boundary.
Providing and Making AAI logo of 450 mm height, Logo should be painted with synthetic enamel paint in blue colour. (A sample of the Logo to be made and get approved by EIC and after getting approval only work to be continued).
Sanjib Saha
L K BUILDERS
M/s. Sharma Traders
Baltej Infra LLP
CIS GLOBAL INFRATECH PRIVATE LIMITED
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .