Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-Finance 11 C GROUND FLOOR DYADER ENCLAVE VIKAS NAGAR ITTAM NAGAR WEST DELHI 110059 | WEST | DELHI | 110059 | ₹4.3 L | L1 | Accepted-Finance ok |
| 2 | L2₹4.3 LAccepted-Finance | ₹4.3 L | L2 | Accepted-Finance ok |
| 3 | L3₹4.5 LAccepted-Finance 272 VIKAS KUNJ VIKAS PURI NEW DELHI 110018 | WEST | DELHI | 110018 | ₹4.5 L | L3 | Accepted-Finance ok |
| 4 | L4₹4.7 LAccepted-Finance | ₹4.7 L | L4 | Accepted-Finance ok |
| 5 | L5₹4.7 LAccepted-Finance N A | NA | NA | 121004 | ₹4.7 L | L5 | Accepted-Finance ok |
Tender Value
₹5.7 L
EMD Value
₹11,476
Closing Date
19 Feb 2026, 3:00 pmClosed
Assistant Engineer ( E )
Assistant Engineer ( E ) NWESD-II, PWD, Pitampura Police Lines, Delhi
District Office F-Block Mangolpuri,Women Silai Center Sultanpuri, Civil Sub-Division Offices and other miscellaneous sites during 2025-26 (Replacement of Old STAC/WTAC).
2026_PWD_286741_1
184/EE(E)/AE(E)-II/NWED/PWD/ 2025-26
Open Tender
Electrical Works
30 days
Mangolpuri
Please refer Tender documents.
10 documents required · 10 mandatory
₹0
₹11,476
Yes
27 Feb 2026
12 Feb 2026
19 Feb 2026
12 Feb 2026
19 Feb 2026
12 Feb 2026
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group C
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole
b) Single pole and neutral
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
Supplying , Installation, Testing and Commissioning of Window type Air conditioners complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing, cooling, dehumidification, air circulation, R-32/R-410A /R-407B Green Refrigerant with Scroll / rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB), antifreeze thermostat on the coil as a safety feature, complete with fixing including T&P & labour etc as required complete in all respect as specified of following capacity. Sound level of up to 50dB inside the room is acceptable. The unit shall be in confirmation with IS 1391 Part-I 2023 and CPWD Specification. The system shall be able to deliver 100% of the rated capacity upto 42 0C. The system shall be able to operate up to 50 0C (out door ambient temperature). a) 1.5 TR with Inverter 5 Star BEE rating
Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R- 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). a)1.5 TR with 5 Star BEE Rating
Supplying &Fixing of 4 KVA capacity automatic voltage stabilizer with time delay relay and high/low\ voltage trip facility input voltage 150V to 290V and output voltage 220+10% with copper flexible cable connection etc. as required at site. (For 1.5 Ton Ac)
Supplying & Fixing of 5 KVA capacity automatic voltage stablizer with time delay relay and high/low voltage trip facility having voltage range 150 V to 280 V +10% with copper flexible cable connection i/c mounting of stabilizer unit with cutting of existing board frame & mounting arrangement etc. as required at site. (For 1.5 TR AC)
Supplying & fixing of 300-305 mm sweep 1400 RPM 230 Volt 1-ph 50 Hz AC heavy duty Exhaust fan in the existing opening including making good the damage, connection, testing and commissioning etc. as reqd.
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : a) 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
b) 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
SITC of Reverse Osmosis(RO) System of 50 LPH along with Pre Filter Bowl set of 20” designed for Treatment of saline water in the TDS range of 500-2000 ppm having 7-stage purification having Particulate Filter-Membrane Life Enhancer-Sediment Filter-Pre Carbon Filter- RO Membrane-Post Carbon Filter-UV Lamp. The unit has body of CRCA Powder Coated. The TDS Rejection is 90% along with 50% Purified Water Recovery etc as required.
Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Al armoured power cable of 1.1 KV grade of following size on wall surface/recess as reqd. a) size 3 X 10 sq. mm
Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor armoured power cable of 1.1 kV grade of following size DWC/HDPE/ RCC/ HUME/METAL as required. a) size 3 X 10 sq. mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. a) 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 3 X 10 sq. mm (22mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
SITC of New generation, IP 65 LED, 25 watt post-top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source. Opal Cover offers soothing uniform illumination for different applications etc. as required at site
Credit for following old/dismantle material received from above work i/c dismantling & removal from site. a) Assorted Window/Split Type Air Conditioner Unit 1.5/2 TR
b) Assorted Voltage Stabilizer 4 KVA/ 5KVA
c) Assorted Ceiling Fan/ Exhuast Fan
d) Assorted MCB
e) Post Top Lamp
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.28 MB
BOQ_379724.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid