| Sl No | Description | Qty | Unit | JAYBEECO L3 | T.D.K. ENTERPRISE L1 | PARTHA SARKAR L2 |
|---|---|---|---|---|---|---|
| 1.00 | Charge for servicing 3 Panel 630A VCB HT Breaker using skilled personnel incl. thoroughly cleaning & removing corrosion from busbar surface, tightening of all nuts bolts etc. as per EIC. | 3 | Units | 15,500 ₹46,500 | 15,500 ₹46,500 | 16,000 ₹48,000 |
| 2.00 | Charge for testing CT Ratio & Insulation test as per direction of EIC | 3 | Units | 3,000 ₹9,000 | 3,000 ₹9,000 | 2,000 ₹6,000 |
| 3.00 | Panel alignment incl. control wiring checking & tightening as per direction of EIC | 3 | mtr | 4,500 ₹13,500 | 4,000 ₹12,000 | 5,000 ₹15,000 |
| 4.00 | Charge for testing of Breaker Timing & Contact Resistance Check (CRM) as per direction of EIC | 3 | mtr | 1,300 ₹3,900 | 1,300 ₹3,900 | 1,200 ₹3,600 |
| 5.00 | Charge for Insulaion Resistance (IR) Test as per direction of EIC | 1 | nos | 1,100 ₹1,100 | 1,000 ₹1,000 | 1,000 ₹1,000 |
| 6.00 | Charge for protection testing by primary injection test kit as per direction of EIC | 3 | sqmtr | 3,500 ₹10,500 | 3,000 ₹9,000 | 3,600 ₹10,800 |
| 7.00 | Charge for servicing, cleaning, testing of all accessories of 750 KVA dry type transformers as per direction of EIC | 2 | nos | 25,000 ₹50,000 | 22,500 ₹45,000 | 22,500 ₹45,000 |
| 8.00 | Charge for servicing, cleaning of all accessories, minor repairing, tightening of all nut bolts etc. of the existing service LT Panel as per the direction of EIC incl preventive maintenance of 3 nos. ACB. | 1 | nos | 15,000 ₹15,000 | 16,000 ₹16,000 | 16,000 ₹16,000 |
| 9.00 | Add GST % 18% | 1 | Job | 0 ₹26,910 | 0 ₹25,632 | 0 ₹26,172 |
| 10.00 | Add CESS % 1% | 1 | Job | 0 ₹1,764.1 | 0 ₹1,680.32 | 0 ₹1,715.72 |
Tender Value
Refer Docs
EMD Value
₹3,395
Closing Date
9 Feb 2026, 2:00 pmClosed
Assistant Engineer, RanaghatElect Sub Dvn
Silver Jubilee Road Ranaghat Nadia
Servicing and repairing of the 2x750kVA Sub-Station at Nadia District Hospital Sadar Campus
2026_WBPWD_996266_1
WBPWD/AE/e-NIT/06/RH/25-26
Open Tender
ELECTRICAL WORKS M/R
10 days
Assistant Engineer Ranaghat Elect Sub Dvn
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,395
2 Mar 2026
30 Jan 2026
11 Feb 2026
30 Jan 2026
9 Feb 2026
2 Feb 2026
Charge for servicing 3 Panel 630A VCB HT Breaker using skilled personnel incl. thoroughly cleaning & removing corrosion from busbar surface, tightening of all nuts bolts etc. as per EIC.
Charge for testing CT Ratio & Insulation test as per direction of EIC
Panel alignment incl. control wiring checking & tightening as per direction of EIC
Charge for testing of Breaker Timing & Contact Resistance Check (CRM) as per direction of EIC
Charge for Insulaion Resistance (IR) Test as per direction of EIC
Charge for protection testing by primary injection test kit as per direction of EIC
Charge for servicing, cleaning, testing of all accessories of 750 KVA dry type transformers as per direction of EIC
Charge for servicing, cleaning of all accessories, minor repairing, tightening of all nut bolts etc. of the existing service LT Panel as per the direction of EIC incl preventive maintenance of 3 nos. ACB.
Add GST % 18%
Add CESS % 1%
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
BOQ_2438235.xls
BOQ • 0.28 MB
2911.pdf
Tender Documents • 0.50 MB
Download all tender documents and submit your bid