Loading…
Loading…
Tender Value
₹2.5 Cr
EMD Value
₹5.1 L
Closing Date
24 Jun 2026, 12:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
TENDER
25 conditions · 14 needing a document upload
Financial Eligibility Criteria Criteria (Para-10.2 (Pt-I) of GCC April 2022):The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per AnnexureVIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Technical Eligibility Criteria: The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender.
(b) (1)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii)One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfilment of technical eligibility criteria for different components.
b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contract or through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing.
Tender not accompanied by documentary evidence in support of eligibility criteria for similar nature of work will be summarily rejected. (For complete details of the technical eligibility criteria for similar nature of the work, please refer clause 2.0, chapter-3 of the tender document).
Contractors should have valid electrical contractors license for the required voltage level or above the required voltage level issued from any state/Central government licensing board. The intended participant shall upload the valid Electrical contractor's license along with the offer/tender as credential.
Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Regarding technical and financial eligibility criteria, scanned copies of supportive documents/certificates from competent officials are to be submitted along with their offer.
Scanned copies of documents in support of formation/registration of the company/firm/legal authorization of the person to deal with the tender/notarized/registered copies of the documents wherever required as per tender conditions are to be submitted along with offer.
Bid Capacity: ( Applicable ) For works costing more than 10 cr. or as prescribed by Railways through instruction/NIT issued for the work, the tenderers who meet the minimum eligibility criteria will be qualified only if their available bid capacity is equal to or more than the total value of the present tender. Bid Capacity: The tender/technical bid will be evaluated based on bid capacity formula detailed as Annexure-VI of GCC April 2022.
If a bidder has successfully completed a work as subcontractor and the work experience certificate has been issued for such work to the subcontractor by a Govt. Organization or public listed company as defined in Note for Item 10.1 Para 10 of the Tender Form (Second Sheet), the same shall be considered for the purpose of fulfillment of credentials.
During the execution of work, all materials brought to site by the Contractor must be offered for inspection within advance notice of one month prior to actual date of inspection. Inspection of materials will generally be done by RITES. If volume of material of nature does not fall in the category of RITES inspection, then inspection of material will be done on the basis of MTC & GC ( Manufacturer's TC & GC ) with the approval of competent authority. All site acceptance of material must be maintained in one material receipt & issue Register which may be verified by any agency at any time. Supplied Materials must be from Railway Approved approved vendors list.
Definition of Similar Work:- 1) Erection of LT or above voltage level distribution panels. 2) Erection and commissioning of LT or above voltage level line (Overhead or underground) 3) Electrification /rewiring service building , bungalow and quarters. 4)Supply and erection of tower light. 5) Lighting of station /Administrative building/Circulating area. . ."
Deployment of Qualified engineers at work site by the Contractor: The Contractor shall also employ qualified Graduate Engineer (s) or equivalent or qualified diploma engineer (s). 1. Project Manager : 01 nos. Graduate in Engineering/MBA, 10 years (Out of which 3 Yrs in charge of Sub station project). 2.Sr. Engineer : 1 nos. Graduate/ Diploma in Electrical Engg. Experience of 5 Yrs of Graduate , 10 Yrs of Diploma Holder 3. Engineer : 3 nos.Diploma in Electrical Engg. Experiance 5 Yrs 4. Draftsman : 1 nos. Diploma, 3 Yrs experience with knowledge of Auto CAD. In Case the contractor fails to employ the engineer , as aforesaid in Para he shall be liable to pay liquidity damages at the rates as prescribed in the tender. Project Manager is to be deployed within 30 days of issue of LOA. The program for deployment of other personnel shall be conveyed by Railway and personnel shall be deployed within 30 days of the stated requirement, a failure to deploy any personnel within 30 days o f the stated requirement a penalty shall be imposed for each day of delay as under. (a)Rs 5000/- per person per day for project manager. (b) Rs 4000/- per person per day for Sr. Engineer. (c ) Rs 3000/- per person per day for other personnel.
3 conditions
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
I have read all instruction mentioned in GCC and its latest ammendment.
Electrification, wiring lighting and seperate power supply arrangement of Block-C and left over electrical work at Pataliputra Rail Parisar Digha Patna and any other location under Dy.CEE/Con/N/SPJ
EL-C-N-MHX-ETEN-9-25-26~ECR
EL-C-N-MHX-ETEN-9-25-26
Open
Works - General
12 Months
Purbi Champaran, Bihar
₹0
₹5.1 L
24 Jun 2026
29 May 2026
10 Jun 2026
97 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,52,63,559.92 | ||
| — | 2950.00 | — | — | ||
| Wiring of Light point, fan point and 5 A plug point in a concealed / Casing Capping with a heavy gauge PVC conduit pipe with single core 3/22 SWG(1.5 sq mm) copper wire(Make- Natural White,Havells,Anchore,HPL,or any ISI marked IS: 694/1977 with latest amdt.) complete with controlling Modular switch anchor make and 16 SWG tinned copper wire as ECC. (a) Light point. | — | — | — | 11,36,723.5 | |
| — | 350.00 | — | — | ||
| (b) Fan/Ex.Fan point. | — | — | — | 1,34,162 | |
| — | 299.00 | — | — | ||
| (c) 5 Amp. Plug Points | — | — | — | 52,770.51 | |
| — | 6000.00 | — | — | ||
| Wiring of sub-main in concealed heavy gauge PVC conduit pipe complete with PVC insulated 2x7/22 SWG(2.5 sq mm) copper wire(Make -Natural White,Havells,Anchore,,or any ISI marked IS: 694/1977 ) from D.B. to switch board for light and fan & power plug circuits with ECC 16 SWG copper wire etc. | — | — | — | 3,54,780 | |
| — | 6000.00 | — | — | ||
| Wiring of sub-main in concealed heavy gauge PVC conduit pipe complete with PVC insulated 2x4 sq mm FRLS copper wire(Make -Natural White,Havells,Anchore,HPL,or any ISI marked IS: 694/1977 with latest amdt.) from D.B. to switch board for light and fan & power plug circuits with ECC 16 SWG copper wire etc. | — | — | — | 7,63,200 | |
| — | 5000.00 | — | — | ||
| Wiring of sub-main in concealed heavy gauge PVC conduit pipe complete with PVC insulated 2x6 sq mm FRLS copper wire(Make -Natural White,Havells,Anchore,HPL,or any ISI marked IS: 694/1977 with latest amdt.) from D.B. to switch board for light and fan & power plug circuits with ECC 16 SWG copper wire etc. | — | — | — | 6,35,600 | |
| — | 4000.00 | — | — | ||
| Wiring of sub-main in concealed heavy gauge PVC conduit pipe complete with PVC insulated 2x10 sq mm FRLS copper wire(Make Natural White,-Havells,Anchore,HPL,or any ISI marked IS: 694/1977 with latest amdt.) from D.B. to switch board for light and fan & power plug circuits with ECC 16 SWG copper wire etc. | — | — | — | 5,72,120 | |
| — | 5000.00 | — | — | ||
| Wiring of sub-main in concealed heavy gauge PVC conduit pipe complete with PVC insulated 2x16 sq mm FRLS copper wire(Make -Natural White,Havells,Anchore,HPL,or any ISI marked IS: 694/1977 with latest amdt.) from D.B. to switch board for light and fan & power plug circuits with ECC 16 SWG copper wire etc. | — | — | — | 10,05,000 | |
| — | 250.00 | — | — | ||
| Supplying and fixing 6 pin15/16 Amps modular type socket outlet and 16 Amps modular type switch in suitable modular type metal box with plate etc.including connection,earthing, painting etc, as require. ( Make-Natural White,North west,Crabtree,Kolar's, Havells, Polycab) | — | — | — | 51,772.5 | |
| — | 300.00 | — | — | ||
| Supply , fixing ,testing and Commissioning of single phase power unit for room air conditioners complete with double pole 32 Amp. Tiny tip MCB, single phase motor starter for over load protection & 25 Amp. heavy duty socket and transparent plug with indicator complete etc. as required Make- Natural White,North West,Crabtree, Kolar's, Legrand,Indo Asian,L&T, HPL,Siemens,BCH | — | — | — | 4,65,000 | |
| — | 450.00 | — | — | ||
| Supply and fixing of MS sheet metal recessed type fan box complete with phenolic laminated type sheet cover of suitable size. | — | — | — | 65,025 | |
| — | 4000.00 | — | — | ||
| Supply and fixing of corgated PVC flexible pipe of size 1"/3/4" dia from existing cable connection main switch for cable loop protection | — | — | — | 35,640 | |
| — | 250.00 | — | — | ||
| Supply and fixing of MS sheet metal recessed type board complete with phenolic laminated type sheet cover of suitable size. (a)8"x12"x3" | — | — | — | 43,982.5 | |
| — | 200.00 | — | — | ||
| Size 8"x6"x3" | — | — | — | 28,850 | |
| — | 175.00 | — | — | ||
| Size 6"x4"x3" | — | — | — | 18,119.5 | |
| — | 80.00 | — | — | ||
| Supply, fixing, connection and testing of 4 Way MCB DB with 6/20A SP MCB - 4Nos.complete with sheet metal enclosure with all accessories etc. as required (Including cutting of wall and making good the damages).( Make -Havells, BCH, Natural White, | — | — | — | 1,14,640 | |
| — | 60.00 | — | — | ||
| Supply, fixing, connection & testing of 32A. SPN MCB-2Nos and 4 way MCB DB in a sheet metal enclosure type board complete with all accessories etc. Make:Havells/Standard/HPL/ Legrand/BCH | — | — | — | 67,698 | |
| — | 70.00 | — | — | ||
| supplying and fixing of 8 way , prewired single pole &neutral sheet steel ,MCB consumer unit, 240 volts on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, hinged front acrelic cover for the MCB knobs detachable gland plate, interconnections, including painting, earthing etc. as requiredMake:Havells/Standard/HPL/ Legrand/BCH, | — | — | — | 1,63,450 | |
| — | 400.00 | — | — | ||
| Supply,fixing, connection testing & commissioning of 1x20 W LED batten type fitting . Make : Bajaj, Crompton,Philips,Surya, Havells,HPL,Eveready | — | — | — | 3,39,404 | |
| — | 100.00 | — | — | ||
| Supply installation,testing & commissioning of Integra( surface)mounted down light with white powder coated polycarbonate housing and pressure die- cast heat sink having high efficiency 15 watt 857 LED LHEAAGP7PL1W015 HSN Code 9405 or similar complying spec. Make- havells,Eveready, philips Bajaj or similar | — | — | — | 1,67,000 | |
| — | 85.00 | — | — | ||
| Supply fixing connection& testing of EURO FRESHAIR(Exhaust) fan 4 pole 300 mm sweep metal blade complete with all accessories, including cutting of wall and making good the damages. Make -Khaitan or similar | — | — | — | 67,839.35 | |
| — | 300.00 | — | — | ||
| Supply,fixing & commissioning of 1200/1400 mm sweep ceiling Fan decorative type (5 star rated) with electronic Fan regulator and all other accessories. Make: Usha, Crompton Greaves, Havells, Bajaj, Philips | — | — | — | 6,99,585 | |
| — | 50.00 | — | — | ||
| Supply, fixing, connection, testing and commissioning of 1.5 Ton split type AC 5 star rated Make- Hitachi, Samsung, LG, Carrier, Daiekin, O'General | — | — | — | 20,94,535.5 | |
| — | 50.00 | — | — | ||
| "Supply, fixing, connection, testing and commissioning of Electronic digital type wall mounted 5 KVA, single phase automatic voltage stablizer complete with low & high voltage trip and time delay relay 3 minutes delay time suitable for input 140V- 280V, output 200V- 240V and digital display. Make Sen & Pandit, Magno, ACPL." | — | — | — | 2,46,141.5 | |
| — | 75.00 | — | — | ||
| Supply installation of (Five star Rating) 25 Ltr capacity Gyser of plastic Body Make :Usha,Bajaj ,Symphony ,Havells | — | — | — | 6,68,785.5 | |
| — | 75.00 | — | — | ||
| Supply installation,testing & commissioning of cove light Model no- 7010131p6p (Euplug) or similar complying spec. light Strip RGB light colour 30 c dimmable with remote 17 Watt LED(included) 3000k/4000/6500k lumen260 make- philips bajaj, syska Havells or Natural White,similar | — | — | — | 3,21,750 | |
| — | 5.00 | — | — | ||
| Fabrication, supply testing connection and installation of LTTPN distribution board cubical type wall mounted dust & vermin proof made of 16 SWG MS sheet metal on suitable support on MS angel painted with two coats of best quality red oxide iron primer and two coats of synthetic enamelled paint with front operable type suitable for system of 3 phase 415 volts 50 c/s AC supply complete with 200 amp TPN copper bus bar from entire length of panel interconnection with nut bolts providing all necessary material and accessories with following MCB / MCCB panel mounting as required :INCOMING (A)MCCB DTH 200 A range 140-200 amp make L&T/ Standard/HPL-01 No. (B) Voltmeter with selector switch 0-500 volt - 01 nos. (C)Ammeter with selector switch CT operated 200/5 Amps - 1 No. (D) Indicating Lamp R, Y, B ---03 Nos. OUTGOING a) MCB 63 Amp 4 pole make standard/ Natural White/Havells/HPL 06-Nos. | — | — | — | 2,61,073.15 | |
| — | 1000.00 | — | — | ||
| Supply of medium gauge TATA / JINDAL make Or any ISI markedG.I. pipe for protection of cable. (Fixing cost included in cable laying items.) (a)100mm dia. | — | — | — | 5,43,000 | |
| — | 1000.00 | — | — | ||
| Supply and delivery of 4 Core, 120mm², 650/1100V PVC/ XLPE insulated, armored Aluminium conductor cable.(Make: Gloster /Crystal/CCIL/Natural White,/Havells , or similar ISI marked IS: 7098(Pt.I)/1993 or CEE's ER/NER approved make) | — | — | — | 6,13,590 | |
| — | 1000.00 | — | — | ||
| Supply and delivery at site of PVC insulated (Heavy duty of 4 core,25 sqmm ,650/1100V PVC/XLPE insulated ,armored Aluminium conductor cable(Make: Gloster/Natural White,/Havells or simillar ISI marked IS 7098(Pt.I)/1988 or CEE's ER/NER approved make) | — | — | — | 2,97,710 | |
| — | 1000.00 | — | — | ||
| Supply and delivery at site of PVC insulated (Heavy duty of 4 core,70 sqmm ,650/1100V PVC/XLPE insulated ,armored aluminium conductor cable(Make: Gloster/Natural White,/CCIL/MP Cab/Havells or simillar ISI marked IS 7098(Pt.I)/1988 or CEE's ER/NER approved make) | — | — | — | 3,95,000 | |
| — | 2000.00 | — | — | ||
| Supply and delivery at site of PVC insulated (Heavy duty) of 4 Core, 300 mm², 1100V PVC/ XLPE insulated, armored Aluminium conductor cable.(Make: Gloster, Crystal, Natural White,Havells, | — | — | — | 45,48,000 | |
| — | 1000.00 | — | — | ||
| Supply of heavy gauge HDPE pipe 100 mm dia for protection of cable. | — | — | — | 2,62,000 | |
| — | 1000.00 | — | — | ||
| Insertion of GI/HDPE pipe by horizontal drilling pipe pushing method. | — | — | — | 9,03,000 | |
| — | 5000.00 | — | — | ||
| Laying of cable {4+1(spare) to be layed for single core cable}partly through trench at a depth of 1m and filling with sand, brick work or under the road by laying of G.I./HDPE pipe at depth of not less than 1m or either in existing masonary trench or on cable tray or fixed on wall/post with suitable MS flat 35x6mm clamp and saddle including supplying and fixing suitable end termination with cable gland and aluminium lugs wherever required as per instruction of enginer -in- Charge, and refilling with earth etc. complete as required.(Cable supplied by Rly.) | — | — | — | 4,57,750 | |
| — | 20.00 | — | — | ||
| Supply & erection of earthing station as per CEE/CCC's specification with GI earth electrode ,50mm dia and 3m long medium gauge TATA/JINDAL make G.I. pipe brackets at both ends and provided with alternate layer of charcoal and salt in the pit and connection with 4 SWG , G.I. wire from earth electrode to rail pole/DB of Quarter along with masonry work encasing the pit. | — | — | — | 23,220 | |
| — | 10.00 | — | — | ||
| Supply installation, testing & commissioning of Refrigerator Model no RT34M5438R8 capacity 324 liters or similar comlying spec. Make- samsung /whirlpool/LG or similar with stand | — | — | — | 4,18,000 | |
| — | 70.00 | — | — | ||
| Supply, fixing, connection, testing and commissioning of Wall mounting bracket fan 16" sweep make Khetan/Polar/Bajaj/Usha./Natural White | — | — | — | 1,27,844.5 | |
| — | 6.00 | — | — | ||
| Supply, installation, , testing and commissioning of 10 KVA IGBT based Rectifire & Inverter Both side online UPS with 60 mints. Battry backup on full load using 20 nos 12 volt 150 Ah SMF batteries along with MS Rack and inter connecting cable Specification is 3PH-3PH, 240 volt DC Make- Numeric ,Tritonics,Consul | — | — | — | 21,00,000 | |
| — | 1.00 | — | — | ||
| Fabrication, supply, installation, testing & commissioning of floor mounted cubical type LT panel board made of 50mm x 50mm x 6mm MS angle and 50mm x 6mm MS flat and 16 SWG M.S. sheet complete with 800 A TPN Copper Bus bar including powder coated painting (Semens Gray) & consisting the followings. (A) Incoming-800 Amp ACB Microprocessor release , 4 pole( Make Indo Asian,Legrand,Havells.L&T, siemens Drowout type . along with overload , short circuit and earth fault protection)-----1no. (B) Voltmeter with selector switch (0-500V) AE make--1 no. (C) Ammeter (AE make ) 0-800 A, C.T. operated with CT ratio 800:5 along with selector switch---1 no. (D) L.E.D. with indication l;amp (RYB)-----3 nos. (E) Outgoing:- (i) 800 A 4 pole change over switch ( Inter connection with copper flat of 800 Amp Capacity)-1 nos. (ii) 4oo Amp 4 pole MCCB with Rotery handle -3 nos. (iii) 250 Amp 4 pole MCCB with Rotery handle -1 nos . (iv) 200 Amp 4 pole MCCB with Rotery handle -3 nos. (v) 100 Amp 4 pole MCCB with Rotery handle -6 nos. (MCCB & Change over switch make- L&T/Havell's ,Indo Asian ,Legrand) (vi)Duel sorce KWH Meter -13 no (vii)Multifunction meter -2 no (viii)Control MCB 6 Amp SP-45 no | — | — | — | 11,76,284 | |
| — | 2.00 | — | — | ||
| Fabrication, supply, installation, testing & commissioning of floor mounted cubical type LT panel board made of 50mm x 50mm x 6mm MS angle and 50mm x 6mm MS flat and 16 SWG M.S. sheet complete with 800 A TPN Copper Bus bar including powder coated painting (Semens Gray) & consisting the followings. (A) Incoming-800 Amp ACB Microprocessor release , 4 pole( Make Indo Asian,Legrand,Havells.L&T, siemens Drowout type . along with overload , short circuit and earth fault protection)-----1no. (B) Voltmeter with selector switch (0-500V) AE make--1 no. (C) Ammeter (AE make ) 0-800 A, C.T. operated with CT ratio 800:5 along with selector switch---1 no. (D) L.E.D. with indication l;amp (RYB)-----3 nos. (E) Outgoing:- (i) 800 A 4 pole change over switch ( Inter connection with copper flat of 800 Amp Capacity)-1 nos. (ii) 4oo Amp 4 pole MCCB with Rotery handle -3 nos. (iii) 250 Amp 4 pole MCCB with Rotery handle -1 nos . (iv) 200 Amp 4 pole MCCB with Rotery handle -3 nos. (v) 100 Amp 4 pole MCCB with Rotery handle -6 nos. (MCCB & Change over switch make- L&T/Havell's ,Indo Asian ,Legrand) (vi)Duel sorce KWH Meter -13 no (vii)Multifunction meter -2 no (viii)Control MCB 6 Amp SP-45 no " | — | — | — | 20,36,200 | |
| — | 2.00 | — | — | ||
| Supply and delivery at site, (12.5 HP)15000 GPH x 46 mtrs head submersible pump set complete with coupled motor of appropriate size suitable for operation in AC supply, 3 phase, 50Hz,415V(±5 to 10%) including wiring and connection of motor pump set as per CEE/CCC specification. Make: KSB, Crompton, Polar, Jyoti | — | — | — | 4,98,406.86 | |
| — | 2.00 | — | — | ||
| Installation, testing and commissioning of the above 15000 GPH pump set. | — | — | — | 67,194.64 | |
| — | 150.00 | — | — | ||
| Supply & Installation of black steel pipe 'B' class (TATA/JINDAL) 4" dia. | — | — | — | 62,662.5 | |
| — | 100.00 | — | — | ||
| Supply and delivery of Finolex/Anchor/Polycab make Submersible cable of 3 core 16 sq mm, 600 V including connection with pump, motor , pannel. | — | — | — | 91,400 | |
| — | 4.00 | — | — | ||
| Supply and fixing of sluice valve ISI mark 4" dia. | — | — | — | 24,836.8 | |
| — | 1.00 | — | — | ||
| Supply and fixing of clamp 4" dia suitable for above pump with nuts & bolts. | — | — | — | 2,357.03 | |
| — | 2.00 | — | — | ||
| Supply, fixing, connection, testing & commissioning of automatic star delta starter(confirms to IS 13947-4) suitable for above pump, 415V,3 phase motor as per Havells type ASDSE2G0 AND cat. No. PASD2G00. (Make: Cromton, L&T, Kirloskar or similar) | — | — | — | 40,456.08 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .