Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAdmitted-Finance H NO 698 SECTOR 10 PANCHKULA HARYANA 134109 | PANCHKULA | PANCHKULA | HARYANA | 134109 | L1 | Admitted-Finance | |
| 2 | L2₹17.7 L+₹1.7 L (10.7%)Admitted-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L2 | Admitted-Finance | |
| 3 | L3₹19.5 L+₹3.5 L (21.8%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹21.3 L+₹5.3 L (33.3%)Admitted-Finance | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Goyal Engineers L3 | R N Enterprises L2 | bharat contrectors L1 | M/s Seerat Enterprises L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour for taking down ceiling fan of any size/ sweep after disconnecting the wire from existing ceiling rose dismantaling of blades and deposited to store for repair, complete all as specified and directed by Engineer-in-Charge. | 150 | EACH | 25 ₹3,750 | 10 ₹1,500 Lowest | 30 ₹4,500 | 60 ₹9,000 |
| 2.00 | Supply and fixing in repair fan condencer 2.5/ 4 MFD, 240 volts suitable capacity for ceiling/ exhaust Fan , complete all as specified and directed by Engineer-in-Charge. | 120 | EACH | 25 ₹3,000 | 35 ₹4,200 | 20 ₹2,400 Lowest | 25 ₹3,000 |
| 3.00 | Supply and fixing in repair ball bearing of suitable size and capacity for ceiling/ Exhaust fan, complete all as specified and directed by Engineer-in-Charge. | 80 | EACH | 40 ₹3,200 | 40 ₹3,200 | 20 ₹1,600 Lowest | 50 ₹4,000 |
| 4.00 | Supply and fixing in repair hanging assembly set comprising with rubber reel, MS clamps, nuts, bolts with one lock hole and lock pins suitable for any type of fans and down rods, complete all as specified and directed by Engineer-in-Charge. | 80 | EACH | 20 ₹1,600 Lowest | 40 ₹3,200 | 50 ₹4,000 | 120 ₹9,600 |
| 5.00 | Material and labour for painting of ceiling fan using synthetic enamel paint in two coats over one coat of primer of any make/sweep/model etc after cleaning/washing and fill up cavities using filler including writing MES NO Black Colour, complete all as specified and directed by Engineer-in-Charge. | 60 | EACH | 150 ₹9,000 | 100 ₹6,000 | 50 ₹3,000 Lowest | 80 ₹4,800 |
| 6.00 | Material and labour for hanging only ceiling fan any type/sweep after repair and connecting up including provision of cable from ceiling rose to connector to fan including refixing of blades, complete all as specified and directed by Engineer-in-Charge. | 150 | EACH | 25 ₹3,750 Lowest | 40 ₹6,000 | 40 ₹6,000 | 80 ₹12,000 |
| 7.00 | Material and labour for rewinding of ceiling fan of any size with super enameled copper wire of existing gauge incuding varnishing and drying and reassembling and testing of size 1200/ 1400 mm sweep, complete all as specified and directed by Engineer-in-Charge.
NOTE for item No 1 to 7 : -(i) Fans to be repaired/ rewinded will be handed over to contractor at MES store yard after cutting the burnt winding in presence of Engr-in-charge and cost of cutting of winding shall be included in the quoted rate.
(ii) The cost of shifting the fan from MES store yard to contractors workshop and back shall be included in the item.
(iii) Fans will be issued to the contractor in lots of 10 Nos and more for which, contractor shall ensure that minimum lot of 10 number each be returned to the department on every fifth day from the issue of fans after carried out rewinding and other repair, in failing so, the amount @ Rs. 20/- per fan per day shall be deducted from the contractor due till the returning of fan duly tested. | 80 | EACH | 180 ₹14,400 Lowest | 200 ₹16,000 | 200 ₹16,000 | 280 ₹22,400 |
| 8.00 | Material and labour for taking down Exhaust fan / wall mounted fan of any size/ sweep after disconnecting the wire from existing ceiling rose dismantaling of blades and deposited to store for repair, complete all as specified and directed by Engineer-in-Charge. | 30 | EACH | 25 ₹750 Lowest | 25 ₹750 Lowest | 30 ₹900 | 80 ₹2,400 |
| 9.00 | Material and labour for rewinding of Exhaust fan/wall fan of any size with super enameled copper wire of existing gauge incuding varnishing and drying reassembling and testing complete of size 230 to 450 mm sweep, complete all as specified and directed by Engineer-in-Charge.
NOTE for item No 2,3 and 8 to 12 : -(i) Fans to be repaired/ rewinded will be handed over to contractor at MES store yard after cutting the burnt winding in presence of Engr-in-charge and cost of cutting of winding shall be included in the quoted rate.
(ii) The cost of shifting the fan from MES store yard to contractors workshop and back shall be included in the item.
(iii) Fans will be issued to the contractor in lots of 10 Nos and more for which, contractor shall ensure that minimum lot of 10 number each be returned to the department on every fifth day from the issue of fans after carried out rewinding and other repair, in failing so, the amount @ Rs. 20/- per fan per day shall be deducted from the contractor due till the returning of fan duly tested. | 20 | EACH | 350 ₹7,000 | 200 ₹4,000 Lowest | 200 ₹4,000 Lowest | 280 ₹5,600 |
| 10.00 | Supply and fixing in repair metal fan blade including fixing mountings and accessories of exhaust fan of 230 to 450 mm sweep, complete all as specified and directed by Engineer-in-Charge. | 20 | EACH | 350 ₹7,000 | 150 ₹3,000 | 50 ₹1,000 Lowest | 350 ₹7,000 |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
28 Oct 2025, 6:00 pmClosed
SHRI ABHINANDAN KUMAR MISHRA, EE, IDSE
GE (SOUTH) AMBALA CANTT
REPAIR/MAINT OF INTERNAL ELECTRIFICATION SYSTEM AND DAY TO DAY MAINT/ASSOCIATED WORKS INCLUDING CEILING FANS GEYSERS EXHAUST FANS AT VARIOUS OTM ACCN IN THE AREA OF MAHATMA GANDHI ROAD AND ADJOINING AREA UNDER GE(S) AMBALA CANTT
2025_MES_733065_1
GE(SOUTH)/AMB-53/2025-2026
Open Tender
Civil Works
Item Rate
180 days
GE (SOUTH) AMBALA CANTT
AS PER NIT
9 documents required · 9 mandatory
₹500
GE (SOUTH) AMBALA CANTT
₹76,000
Yes
10 Nov 2025
27 Sept 2025
30 Oct 2025
27 Sept 2025
28 Oct 2025
14 Oct 2025
27 Sept 2025 - 13 Oct 2025
Amount
Material and labour for taking down ceiling fan of any size/ sweep after disconnecting the wire from existing ceiling rose dismantaling of blades and deposited to store for repair, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair fan condencer 2.5/ 4 MFD, 240 volts suitable capacity for ceiling/ exhaust Fan , complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair ball bearing of suitable size and capacity for ceiling/ Exhaust fan, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair hanging assembly set comprising with rubber reel, MS clamps, nuts, bolts with one lock hole and lock pins suitable for any type of fans and down rods, complete all as specified and directed by Engineer-in-Charge.
Material and labour for painting of ceiling fan using synthetic enamel paint in two coats over one coat of primer of any make/sweep/model etc after cleaning/washing and fill up cavities using filler including writing MES NO Black Colour, complete all as specified and directed by Engineer-in-Charge.
Material and labour for hanging only ceiling fan any type/sweep after repair and connecting up including provision of cable from ceiling rose to connector to fan including refixing of blades, complete all as specified and directed by Engineer-in-Charge.
Material and labour for rewinding of ceiling fan of any size with super enameled copper wire of existing gauge incuding varnishing and drying and reassembling and testing of size 1200/ 1400 mm sweep, complete all as specified and directed by Engineer-in-Charge. NOTE for item No 1 to 7 : -(i) Fans to be repaired/ rewinded will be handed over to contractor at MES store yard after cutting the burnt winding in presence of Engr-in-charge and cost of cutting of winding shall be included in the quoted rate. (ii) The cost of shifting the fan from MES store yard to contractors workshop and back shall be included in the item. (iii) Fans will be issued to the contractor in lots of 10 Nos and more for which, contractor shall ensure that minimum lot of 10 number each be returned to the department on every fifth day from the issue of fans after carried out rewinding and other repair, in failing so, the amount @ Rs. 20/- per fan per day shall be deducted from the contractor due till the returning of fan duly tested.
Material and labour for taking down Exhaust fan / wall mounted fan of any size/ sweep after disconnecting the wire from existing ceiling rose dismantaling of blades and deposited to store for repair, complete all as specified and directed by Engineer-in-Charge.
Material and labour for rewinding of Exhaust fan/wall fan of any size with super enameled copper wire of existing gauge incuding varnishing and drying reassembling and testing complete of size 230 to 450 mm sweep, complete all as specified and directed by Engineer-in-Charge. NOTE for item No 2,3 and 8 to 12 : -(i) Fans to be repaired/ rewinded will be handed over to contractor at MES store yard after cutting the burnt winding in presence of Engr-in-charge and cost of cutting of winding shall be included in the quoted rate. (ii) The cost of shifting the fan from MES store yard to contractors workshop and back shall be included in the item. (iii) Fans will be issued to the contractor in lots of 10 Nos and more for which, contractor shall ensure that minimum lot of 10 number each be returned to the department on every fifth day from the issue of fans after carried out rewinding and other repair, in failing so, the amount @ Rs. 20/- per fan per day shall be deducted from the contractor due till the returning of fan duly tested.
Supply and fixing in repair metal fan blade including fixing mountings and accessories of exhaust fan of 230 to 450 mm sweep, complete all as specified and directed by Engineer-in-Charge.
Material and labour for fixing only exhaust fan any type/sweep after repair and connecting up including provision of cable from ceiling rose to connector to fan including refixing of blades, louvers etc, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of plastic body exhaust fan, AC singal phase, 240 volts of size 250 mm sweep with heavy duty, plastic body with louvers connecting up including provision of fixing clamp, nut bolts and cable from ceiling rose or connector to fan,including taking down old unserviceable pastic body exhaust fan, complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable geyser of cap 25 ltrs including all necessary electrical/water connection and keeping in safe custody for reuse including all necessary minor repairs /servicing etc and checking serviceability of parts, necessary cleaning, soldering / welding works as required and reassembling the geyser, making necessary adjustment and refixing the repaired geyser in position, connecting to existing electric and water connections and testing at site, complete all as specified and directed by Engineer-in-Charge. Note : The cost of minor repair including following works deemed to be included in quoted rates. (a) Inspection of geyser after opening bottom cover plate. (b) Examine any water leakage from geyser/storage tank. (c) Carry out operation of all stop cocks, pressure reducing valves, etc. to ensure free movement of the working parts. (d) Replace washers and glands to ensure smooth functioning. (e) Inspect vent pipes and remove blockage obstruction if any. (f) Check and correct earth continuity of electrical items. (g) Check and correct temperature setting of thermostats. (h) Items reqd for replacement will measured under respective item of BOQ.
Taking down old unserviceable geyser of cap 50 ltrs including all necessary electrical/water connection and keeping in safe custody for reuse including all necessary minor repairs /servicing etc and checking serviceability of parts, necessary cleaning, soldering / welding works as required and reassembling the geyser, making necessary adjustment and refixing the repaired geyser in position, connecting to existing electric and water connections and testing at site , complete all as specified and directed by Engineer-in-Charge. Note : The cost of minor repair including following works deemed to be included in quoted rates. (a) Inspection of geyser after opening bottom cover plate. (b) Examine any water leakage from geyser/storage tank. (c) Carry out operation of all stop cocks, pressure reducing valves, etc. to ensure free movement of the working parts. (d) Replace washers and glands to ensure smooth functioning. (e) Inspect vent pipes and remove blockage obstruction if any. (f) Check and correct earth continuity of electrical items. (g) Check and correct temperature setting of thermostats. (h) Items reqd for replacement will measured under respective item of BOQ.
Supply only heating element of capacity 2 KW of geysers of any make ISI marked , complete all as specified and directed by Engineer-in-Charge.
Supply only apparatus plate assembly with rubber gasket including nuts, bolts, washers for geysers of 50/35/25 ltrs capacity , complete all as specified and directed by Engineer-in-Charge.
Supply only thermostat ISI marked suitable for the Geysers 25 ltrs capacity, 20 Amps, 240 Volts AC, adjustable type, 210 mm long or nearest size as per sample , complete all as specified and directed by Engineer-in-Charge.
Supply only thermostat ISI marked suitable for the Geysers 50 ltrs capacity,20 Amps, 240 Volts AC, fixed type,300 mm long or nearest size, Set at 90+/-6 degreeC as per sample , complete all as specified and directed by Engineer-in-Charge.
Supply only temperature resistent SS braided pipe suitable to sustaine pressure up to 8 bar 90 Cm long suitable for out going / Hot water connections of Geyser with washer etc, complete all as specified and directed by Engineer-in-Charge.
Supply only Non-return valve 15mm / 20mm dia of brass ISI marked as per requirement , complete all as specified and directed by Engineer-in-Charge.
Supply only Indicators of Geysers of any capacity/type (Red & Green) as per requirement , complete all as specified and directed by Engineer-in-Charge.
Supply only Geyser storage inner tank made out of stainless steel sheet suitable for 25 ltrs capacity , complete all as specified and directed by Engineer-in-Charge.
Supply only geyser storage inner tank made out of stainless steel sheet suitable for 50 ltrs capacity , complete all as specified and directed by Engineer-in-Charge.
Supply only nut and long bolt set fastener made of steel, length not less than 6 cm as per site requirement for fixing of geysers , complete all as specified and directed by Engineer-in-Charge.
Supply only safety valve plug made out brass metal with fusible lead, inner thread type suitable for geyser of any type/capacity , complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair copper cable PVC insulated and PVC sheathed flexible size 2.5 Sqmm 3 core , complete all as specified and directed by Engineer-in-Charge. (Cable shall be in suitable length as per site requirement).
Supply only heating element of capacity 1.5 KW of geysers of any make ISI marked , complete all as specified and directed by Engineer-in-Charge.
Supply only metal clad plug top 3 pin 20 Amp 230 Volts round shape suitable for AC box , complete all as specified and directed by Engineer-in-Charge.
Material and labour for attending day to day complaints of E/M nature by means of checking unserviceable Electrical fitting and fixture and emergent fault rectification in elctrical circuit including no light , earth leakage, short cicuit, neutral break mains /sub mains/internal circuits of existing system of main building / block ,making continious electric supply including carrying out minor repairs etc to make system in order / functional by replacing, copper cable , copper thimbles, glands, earthing wire complete all as specified and as directed as required at site by Engineer-in-Charge. NOTE : - (a) Items reqd for replacement such as switches, sockets for power/light/ fan/ bell/geyser points including complete will be measured and paid under respective items of BoQ. (b) Contractor rep/supervisor will report to MES Service Centre alongwith qualified/Experianced electrician and helper to collect dockets between 0900 hrs to 1000 hrs on all working days for rectification of complaints and resubmit the dockets after completion of each job of each job on the same day. If contractor is failed to submit the docket within 48 hours after issuing of dockets , the contractor i liable to pay the penalty i.e. 20.00 per docket per day till the re-submission of docket. (c) Contractor will attend emergent nature of work i.e. no light, short circuit after working hours/holiday as when ordered. The rate of the is deemed to be included in above quoted rates.
Supply only switch piano 5 Amps, flush type, single pole, one way, 230 volt, AC supply, ISI Marked, , complete all as specified and directed by Engineer-in-Charge.
Supply only switch piano 15 Amps flush type one way 230 Volts, 50 Hz , AC supply, , complete all as specified and directed by Engineer-in-Charge.
Supply only bell push 5 Amps, flush type, single pole, one way, 230 volt , AC supply, , complete all as specified and directed by Engineer-in-Charge.
Supply only socket outlet 3 pin 6 amps, 230 volt. flush type, ISI Marked, , complete all as specified and directed by Engineer-in-Charge.
Supply only socket outlet 2 in 1, 6 pin 5 /16 Amp and multi pin flush type, , complete all as specified and directed by Engineer-in-Charge.
Supply only ceiling rose surface bakelite 65x50mm, 3 terminal , complete all as specified and directed by Engineer-in-Charge.
Supply only fan regulator electronic step type ,230 Volts, AC supply, suitable for ceiling fan any type/make/sweep, , complete all as specified and directed by Engineer-in-Charge.
Supply only door bell electric ,ding dong /musical type, single phase 230 volts, ISI marked complete all as specified.
Supply only lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, , complete all as specified and directed by Engineer-in-Charge.
Supply only switch modular 6 amps, one way single module as per existing make and type , complete all as specified and directed by Engineer-in-Charge.
Supply only switch modular 16 amps, one way single module as per existing make and type , complete all as specified and directed by Engineer-in-Charge.
Supply only socket modular 6 amps, 5 pin combined universal socket 2 module as per existing make and type , complete all as specified and directed by Engineer-in-Charge.
Supply only socket modular 6/16 amps, 2 in 1, combined universal socket 2 module as per existing make and type , complete all as specified and directed by Engineer-in-Charge.
Supply only fan regulator step type one module / 2 module, 120W, 230 Volts, 50 Hz, AC complete as per existing make and type , complete all as specified and directed by Engineer-in-Charge.
Supply only bell push modular with and including necessary frame and cover i.e. inner and outer plate as per existing make and type , complete all as specified and directed by Engineer-in-Charge.
Supply only Fan condenser 2.5 mfd , complete all as specified and directed by Engineer-in-Charge.
Supply only PVC insulated, unsheathed cable 4.00 Sqmm single core 1100 volt grade with multi stranded copper conductor , complete all as specified and directed by Engineer-in-Charge.
Supply only PVC insulated, unsheathed cable 2.5 Sqmm single core 1100 volt grade with multi stranded copper conductor , complete all as specified and directed by Engineer-in-Charge.
Supply only Cable PVC copper conductor flexible twin core 0.75mm , complete all as specified and directed by Engineer-in-Charge.
Supply only MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 6 to 32 Amps, ISI marked , complete all as specified and directed by Engineer-in-Charge.
Supply only MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 40 to 63 Amps, ISI marked , complete all as specified and directed by Engineer-in-Charge.
Supply only MCB single pole and neutral 240 volts, 16 to 32 Amps,10KA, 50 Hz, 'B' Series , complete all as specified and directed by Engineer-in-Charge.
Supply only PVC Plug Top 3 pin suitable for 5/6 Amp socket complete all as specified and directed by Engr-in-Charge.
Supply only PVC Plug Top 3 pin suitable for 15 Amp socket complete all as specified and directed by Engr-in-Charge.
Supply only MCB single pole and neutral 240 volts, 40 to 63 Amps,10KA, 50 Hz, 'B' Series , complete all as specified and directed by Engineer-in-Charge.
Dismantling/taking down carefully aluminium/ copper point wiring (light, fan,socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of walls,ceilings etc. , complete all as specified and directed by Engineer-in-Charge.
Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH (FIRE Retardant Low Smoke and low Halogen), PVC insulated and unsheathed stranded cable drawn through and including non metallic,medium grade PVC concealed conduit not less than 20mm dia and its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI metal flush boxes made out of 1.2mm thick of any module from 2 to 18 module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly coated with two coats of anti corrosive paint including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over metal flush boxes for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbed surfaces as per existing for one light / fan / Bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH (FIRE Retardant Low Smoke and low Halogen) copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with suitable size of lugs for one light point/ fan point/bell point controlled by one switch , complete all as specified and directed by Engineer-in-Charge. NOTES:- 1. Switch, socket and fan regulators to be measured and paid for separately. 2. All chases will be cut by chase cutter only.
Description all as per item No 56.00 here in before but for socket out let point 5 Amps on same board , complete all as specified and directed by Engineer-in-Charge.
Description all as per item No 56.00 here in before but for socket out let point 5 Amps on independent board , complete all as specified and directed by Engineer-in-Charge.
Description all as per srl item No 56.00 above but point wiring for one socket out let 15&5 Amps (independent) controlled by one switch with using 2.5 Sq mm (nominal area) stranded copper conductor , complete all as specified and directed by Engineer-in-Charge.
Material and labour for point wiring in existing conduit using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH PVC insulated and unsheathed stranded cable drawn through in existing non metallic/mettalic medium grade concealed/Surface conduit and including replacement of its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI metal flush boxes made out of 1.2mm thick of any module from 2 to 18 module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly coated with two coats of anti corrosive paint including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over metal flush boxes for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbed surfaces as per existing for one light / fan / Bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with suitable size of lugs for one light point/ fan point/Bell Point controlled by one switch , complete all as specified and directed by Engineer-in-Charge. NOTES:- 1. Switch, socket and fan regulators to be measured and paid for separately. 2. All chases will be cut by chase cutter only.
Description all as per item No 60.00 here in before but for socket out let point 5 Amps on same board , complete all as specified and directed by Engineer-in-Charge.
Description all as per item No 60.00 here in before but for socket out let point 5 Amps on independent board , complete all as specified and directed by Engineer-in-Charge.
Description all as per srl item No 60.00 above but point wiring for onesocket out let 15&5 Amps (independent) controlled by one switch with using 2.5 Sq mm (nominal area) stranded copper conductor , complete all as specified and directed by Engineer-in-Charge.
Supply and fix modular switches, one way, 6 amps one module, 230V, 50 Hz supply, , complete all as specified and directed by Engineer-in-Charge.
Supply and fix modular switches, one way, 20 Amps, one module, 230 volt , AC supply, , complete all as specified and directed by Engineer-in-Charge.
Supply and fix modular socket outlet 6 amps, 2/3 pin combined 2 module, 230 volt, , complete all as specified and directed by Engineer-in-Charge.
Supply and fix modular socket outlet 6/20 amps,3 pin, 2 module, , complete all as specified and directed by Engineer-in-Charge.
Supply and fix fan regulator step type one module / 2 module, 100w 230 Volts, 50 Hz, AC , complete all as specified and directed by Engineer-in-Charge.
Supply and fix modular switches, bell push, 6 amps one module, 230V, 50 Hz supply, , complete all as specified and directed by Engineer-in-Charge.
Supply and fix modular blanking plate 1 module , complete all as specified and directed by Engineer-in-Charge.
Supply and fix ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and directed by Engineer-in-Charge.
Supply and fix lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings,complete all as specified and directed by Engineer-in-Charge.
Supply and fix door bell electric ,ding dong /musical type, single phase 230 volts, ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair sheet metal enclosure SP with two pin and earth plug and socket including metal clad top with one single pole, MCB 20 Amps, 'B' curve, 240 volts , complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of LED light fitting 1x20W , 220V,not less than 100 lumen per watt, Aluminium housing AC batten type with driver , holder including 20W LED tube light for connecting up with three core flexiable copper conductor cable of suitablae size from celing rose to connector complete all as specifid and directed. Note: LED cool white/warm white must get approved from engineer-in-charge.
Supply and fix channel for fixing of LED tube rod of CRCA body suitable for 18/20 watt LED tube, high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position , complete all as specified and directed by Engineer-in-Charge. ( Tube rod shall be measured and paid for separately ). Note: - Channel must be get approved from Engr in charge to check fesibilty i.e. one end contact or two end contact
Supply and fix in repair 18 W/ 20W LED tube rod, environment friendly, high efficient, T8 with aluminium extrusion heat sink for optimum performance with high luminous efficiency and easy and taking down existing tube light and removal complete all as specified and directed. Note: - Tube rod must be get approved from Engr in charge to check fesibilty i.e. one end contact or two end contact for fixing in existing LED fittings .
Supply and fix batten type with surface mounted LED tube light fitting with high efficient diffuser mirror light, polycarbonate housing in CRCA body suitable and including 10 watt LED tube rod high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position , complete all as specified and directed by Engineer-in-Charge.Note: LED cool white/warm white must get approved from engineer-in-charge.
Supply and fix bracket for security light made up of 25/40mm dia suitable for security light, 0.9 metre long MS pipe, light grade, bent not less than 100 degree to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts , complete all as specified and directed by Engineer-in-Charge.
Supply and fix LED security light luminaire 30 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDs having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with Two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position , complete all as specified and directed by Engineer-in-Charge.
Supply and fix LED security light luminaire 45 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDs having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with Two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position , complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of Inverter LED tube light fitting 1x20 Watt with minimum 03 hours battery back integrated batten with diffuser and including 20 Watt LED hight efficient , AC 220-240 V, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position , complete all as specified and directed by Engineer-in-Charge.
Supply and fixing recess/ surface mounted/POP ceiling mounted LED flat panel 2' x 2' with high efficient LEDs and glare free full decorative light fitting, 36 watt, energy efficient provided with including LED 36 watt with provision of 2/3 core PVC copper conductor cable 1.5 Sqmm size to light fitting and complete including disconnecting and taking down existing light fitting and removal , complete all as specified and directed by Engineer-in-Charge. Note: Recess/Surface mounting must get approved from Engineer-in-charge as per site requirement.
Material and labour for sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 2.5 sqmm drawn in and including rigid non metallic PVC medium grade 20 mm dia New concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 2.5 sqmm,green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface , complete all as specified and directed by Engineer-in-Charge. NOTE: - 3 run of 2.50 sqmm cable with concealed conduct shall be measured as 1 unit.
Material and labour for sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 6sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia New concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 6 sqmm, green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface , complete all as specified and directed by Engineer-in-Charge. NOTE:-3 run of 6.0 sqmm cable with concealed conduct shall be measured as 1 unit.
Material and labour for sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 4 sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia New concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 4 sqmm,green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface , complete all as specified and directed by Engineer-in-Charge. NOTE:- 3 run of 4.0 sqmm cable with concealed conduct shall be measured as 1 unit.
Material and labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6.0 mm thick buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron wire 4 mm as earthing lead (upto terminal point) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 1991(Part-I) Taking out old unserviceable earthing , complete all as specified and directed by Engineer-in-Charge. NOTE : - The rates for earth work, GI protection pipe, funnel, wire wesh, CI cover, etc shall be deemed to be including in quoted rates.
Supply and fixing in repair sheet metal enclosures vertical distribution board VTPN,(MCCB DB) 4 ways, double door , 415 volts with 200 amps rated bus bar IP 54 protection, with shrouded neutral bar and insulated bus bar and earth link, with and including MCCB 4 pole thermal release type ,125AMPS ,25 KA as incomer and MCB s as out going complete with making suitable size of MS cabinet 1.2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs and making good the disturbed surface matching with existing surface , complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair sheet metal enclosures vertical distribution board VTPN,(MCCB DB) 4 ways, double door , 415 volts with 200 amps rated bus bar IP 54 protection, with shrouded neutral bar and insulated bus bar and earth link, with and including MCCB 4 pole,100AMPS 16 KA as incomer and MCB s as out going complete with making suitable size of MS cabinet 1.2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs and making good the disturbed surface matching with existing surface , complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair SPN distibution board 8 way, double door, IP 43, as per IS 8623 including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles /gland/gaskets , complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair SPN distibution board 4 way, double door, IP 43, as per IS 8623 including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles /gland/gaskets , complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 6 to 32 Amps, ISI , complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 40 to 63 Amps, ISI marked , complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair MCB single pole and neutral 240 volts, 16 to 32 Amps,10KA, 50 Hz, 'B' Series , complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair MCB single pole and neutral 240 volts, 40 to 63 Amps,10KA, 50 Hz, 'B' Series , complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair PCB unit of suitable size for BLDC Ceiling fan of 1200mm sweep, single phase, 240 V , complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair post top lantern LED 30W , cast aluminium spigot, with high effieient LED light, with poly carbonate diffuser, complete with high efficient LED lamp 30 W and accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable including disconnecting and taking down existing light fitting and removal , complete all as specified and directed by Engineer-in-Charge. Note: LED cool white/warm white must get approved from engineer-in-charge.
Supply and fix in repair MCCB four pole 415 volts, 125 Amps,25KA, 50 Hz, thermal release , complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair MCCB four pole 415 volts, 100 Amps,16KA, 50 Hz thermal release , complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire or pvc conduit, one twin core cable circulat of size 6 Sqmm including all incoming and outgoing connection with proper size of thimble complete all as directed and specified.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire or pvc conduit, one twin core cable circulat of size 10 Sqmm including all incoming and outgoing connection with proper size of thimble complete all as directed and specified.
Material and labour for taking down existing lighting fiting any type/size/Make/capacity and re-fixing the same after minor repair/cleaning including replacement connection wire with suitable size coper wire twin core 0.75 sqmm for connection from ceiling rose to light fitting , complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs LED Lamps 9 Watt B22/E27 suitable for batten holder including taking down existing lamp of any description , complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs LED Lamps 12 Watt B22/E27 suitable for batten holder including taking down existing lamp of any description , complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking down old existing wall fitting of any description and in any position and Supply and fixing surface mounting type LED round type Decorative ,wall mouting , STYLO bowl type/metal base with glass with 7 Watt LED Warm white B22 Lamp including connecting up with three core 1.5 sqmm flexible copper conductor cable , complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking down old existing bollard light fitting of any description and in any position and supply and fix in repair LED based Bollard light 10 watt with aluminium pipe housing not less than 65mm dia with glare free PMMA Diffuser, IP 65 of height not less than 600mm with and including 10 watt LED including base frame made of sheet metal including necessary excavation,removal and PCC 1:3:6 work as directed etc , complete all as specified and directed by Engineer-in-Charge.Note:LED(cool white or warm white) must get approved from engr-in charge.
Disconnecting and taking down old existing bollard light fitting of any description and in any position and supply and fix in repair LED based Bollard light 15 watt with aluminium pipe housing not less than 65mm dia with glare free PMMA Diffuser, IP 65 of height not less than 1 m with and including 15 watt LED including base frame made of sheet metal including necessary excavation,removal and PCC 1:3:6 work as directed etc , complete all as specified and directed by Engineer-in-Charge.Note:LED(cool white or warm white) must get approved from engr-in charge.
Supply and fixing of recessed/surface mounted LED Flat panel 2`x 4` with high efficent LEDs and glare free full decorative light fitting 72 Watt , engergy efficient provided with including LED 72 Watt with provision of 2/3 core PVC copper conductor cable 1.5 sqmm size to light fitting and complete including disconnecting and taking down old existing light fitting of any description and in any position , complete all as specified and directed by Engineer-in-Charge.Note: Recess/Surface mounting must get approved from Engineer-in-charge as per site requirement
Material and labour for replacemnt of existing rusted modular metal flush box of 1 to 3 module and fixing of GI flush box of 1 to 3 module for housing of modular switch, sockets, regulators etc including taking down existing flush box and making good the disturbed surface after completion of work all as specified and as directed
Material and labour for replacemnt of existing rusted modular metal flush box of 4 to 8 module and fixing of GI flush box of 4 to 8 module for housing of modular switch, sockets, regulators etc including taking down existing flush box and making good the disturbed surface after completion of work all as specified and as directed
Material and labour for replacemnt of existing u/s modular cover plate with frame of 1 to 3 module and fixing modular cover plate of 1 to 3 module for housing of modular switch, sockets, regulators etc including taking down existing modular cover plate with frame all as specified and as directed
Material and labour for replacemnt of existing u/s modular cover plate with frame of 4 to 8 module and fixing modular cover plate of 4 to 8 module for housing of modular switch, sockets, regulators etc including taking down existing modular cover plate with frame all as specified and as directed
Material and labour for taking down existing light fitting of any type alongwith Any type of pipe/ pole of any dia upto 3 mtr height and supply and fixing of MS pipe (Hot dipped Galvanized) decorative pole in two sections i.e Top pipe not less than 75 mm outside dia x 2500 mm long and Bottom pipe not less than 110mm outside dia x 500 mm long, including aluminium emblishment in between top & bottom pipe thickness of pipe not less than 3 mm with base plate 250 x 250 x 12mm thick having 14mm dia hole for fixing of foundation 'J' bolts of size 12mm dia x 450 mm "J" including 115 x 200 mm long utility window in pole, fixing of suitable size nuts/bolts and washers, including decorative pole base cover complete with suitable rated aluminium bus bar mounted on porculine insulator for connection of light fittings, enhancing the apperance of the pole Tripple layer metallic PU paint (Etching, Epoxy & PU) suitable for pole including all fixing accessories including decorative pole mounted DOUBLE ARM SUSPENDED DESIGN BRACKET with integrated energy efficient suspended type LED light 30-40 W of suitable outer dia to fix on both arm of bracket fixed properly,designed for outdoor park environments. The bracket shall be fabricated from mild steel with height not less than 700mm X width not less than 1000mm and MS pipe dia not less than 60 mm with 42 mm outer dia for lights arrangement and ornamental design elements to complement the landscape aesthetics with triple layer PU paint glossy black with top design in glossy golden.The LED luminaire shall be IP-65 rated for outdoor use and provide warm and neutral white illumination.The bracket shall be securely fixed at the specified height on newly installed lighting poles and including making necessary nut bolt / threading /welding arrangements to mount the LED suspended lights firmly on both ends of the bracket arm. All associated wiring,mounting accessories ,and electrical connections shall be included necessary excavation, removal and PCC 1:3:6 work suitable to mount the base frame of pole and as specified & directed by engineer in charge etc complete. Note : (i) Quoted rates shall be inclusive of excavation, taking down existing pole, all fixing acessories & PCC 1:3:6 for fixing of pole & suspension type LED luminaire. (ii) Drawing of pole must get approved before installation.. (iii) MS pipe of pole (Top & Bottom) should be ISI marked as per latest standard.
Supply and laying in trenches service cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power 1100 volts grade with stranded aluminium conductorof size 10 Sqmm 2 core complete in repairs, complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 Mtrs wide and not exc. 1.5 Mtr deep and getting out soft/loose soil complete all as specified and as directed by Engineer -in-Charge
Returning, filling in including spreading levelling , watering and well ramming in layers not exc 25cm thick after the cable have been laid testing complete all as specified and directed by Engineer -in-Charge
Removal of excavated surplus soil to a distance not exc 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed by Engineer-in-Charge
Material and Labour for unwashed dry sand cushioning for cable protection , filling in treches complete all as specified and directed by Engineer-in-charge.
Material and labour for Protection to cable with one layer of new bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ bricks , complete all as specified and directed by Engineer-in-Charge.
NOTE:- Amount of credit of Rs. 69,823.00 for retrieved materials is mentioned in Schedule of Credit Page No 19 & 20 of tender documents in pdf form which will be deducted offline while acceptance of tender.
R N Enterprises (BID ID -3459944)
Goyal Engineers (BID ID -3454304)
M/s Seerat Enterprises (BID ID -3460453)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
Tenderdocuments53.pdf
Tender Documents • 0.93 MB
BOQ_820789.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .