| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.5 LAccepted-AOC 00 KANOONGOPURA NORTH MAHILA DISTRICT HOSPITAL BAHRAICH BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | 1 | Accepted-AOC MOM No 1706 dt 24.08.2023 | |
| 2 | 2₹12.6 L+₹7,698 (0.61%)Rejected-Finance | 2 | Rejected-Finance Bidder are Second | |
| 3 | 3₹12.7 L+₹14,573 (1.16%)Rejected-Finance | 3 | Rejected-Finance Bidder are thirrd |
Tender Value
Refer Docs
EMD Value
₹37,850
Closing Date
4 Jul 2023, 12:00 pmClosed
Executive Engineer
33/11 KV Sub Station Doraha Campus Rampur Road Doraha
Laying of LT AB Cable and Supply of its associated decentralized material in 11 KV Bhikampuri feeder emanation form 33/11 KV Sub Station Barhani under EDD Bazpur
2023_UPCL9_59288_1
E Tender No 12/EDD(Bazpur)2023-24
Open Tender
Electrical Works
Item Rate
365 days
Bazpur
As Per Tender NIT and Tender Documents with PQR
3 documents required · 3 mandatory
₹1,180
Yes
EE EDD Bazpur
₹37,850
Yes
6 Sept 2023
5 Jun 2023
5 Jul 2023
5 Jun 2023
4 Jul 2023
5 Jun 2023
Supply Item
Supply of SMC Three Phase L.T. Distribution Box for connection of LT consumer With in built Panel Lock with key, Al bus bar RYB 25x6 mm & Al bus bar N 40x6 mm. MAKE- (SINTEX/Other IS Complied Reputed Company)
Supply of Dead End Clamps With I Hook. (As Per Specification & Drawing of UPCL)
Supply of Suspension Clamps With I Hook. (As Per Specification & Drawing of UPCL)
Supply of L.T. Bare Neutral Connectors PG Clamp 95 sq mm to 25 sq mm single bolt. (As Per Specification & Drawing of UPCL)
Supply of L.T. Bare Neutral Connectors PG Clamp 95 sq mm to 95 sq mm double bolt. (As Per Specification & Drawing of UPCL)
Supply of Shear Head type Insulated Piercing Connector body moulded from high quality mechanical Climate and UV resistant glass reinforced polyamide hot dipped galvanized bolts & contact teeth ABC size 95 Sq mm to 95 sq mm. MAKE- (TYCO/RPG/3M/SICAME/ENSTO)
Supply of Shear Head type Insulated Piercing Connector body moulded from high quality mechanical Climate and UV resistant glass reinforced polyamide hot dipped galvanized bolts & contact teeth ABC size 95 Sq mm to 25/16 Sq mm MAKE- (TYCO/RPG/3M/SICAME/ENSTO)
Supply of Stay Clamp for PCC Pole made of M.S. Flate Size 50x6 mm duly Red Oxide Painted with Fitted 18m dia hole for 65x16 mm nut and bolts and washer without cracks & burrs. (As Per Specification & Drawing of UPCL)
Supply of M.S. Half Clamp for PCC Pole made of M.S. Flate Size 35x5 mm duly Red Oxide Painted with Fitted 18m dia hole for 65x16 mm nut and bolts and washer without cracks & burrs for Fixing of LT Distribution box. (As Per Specification & Drawing of UPCL)
Supply of M.S Clamp for PCC Pole made of M.S. Flate Size 50x6 mm duly Red Oxide Painted with Fitted 18m dia hole for 65x16 mm nut and bolts and washer without cracks & burrs for Dead End Clamp. (As Per Specification & Drawing of UPCL)
Supply of M.S Clamp for PCC Pole made of M.S. Flate Size 50x6 mm duly Red Oxide Painted with Fitted 18m dia hole for 65x16 mm nut and bolts and washer without cracks & burrs for Suspension Clamp. (As Per Specification & Drawing of UPCL)
Supply of Aluminum Lugs 'O' type size 25 mm for connecting PVC cable 4x25 sq mm. (As Per Specification & Drawing of UPCL)
Supply of Aluminium Lugs 'O' type Size 95 mm for connection LT AB Cable to T/F. (As Per Specification & Drawing of UPCL)
Aerial Bunch Cable Laying Work
Cartage of PCC Pole by private truck from store centre Rudrapur /Haldwani/ Kashipur to dump store approx. distance 5 to 80 Km. including loading into truck and unloading at road work site.
Cartage of Small line material by private truck from store centre Rudrapur /Haldwani/ Kashipur to dump store approx. distance 5 to 80 Km. including loading into truck and unloading at road work site.
Erection of PCC Pole after digging of pit size 0.6×0.6 mtrs & 1/6 length of support on 300×300×75 mm stone pad including fixing with all accessories complete in all respect as per Specification of UPCL.
Fixing of Grouting of stay set complete as per RESPO drawing no. RES-16 with stay rod 16×1800 mm stay wire 7/10 SWG including excavation of earth and grouting of stay in pit with CC 1:4:8 in bottom of pit in size 0.60×0.60×0.60 mtrs, including cost of cement, sand and stone ballast etc. fixing of all accessories complete in all respect as per Specification of UPCL.
Fixing of M.S. earthing rod 20×2500 mm for earthing of support as per RESPO drawing No. RES-12 including digging earth rod 2.5 m deep below ground level connected to support with earth wire 7/16 swg fixing of all accessories complete in all respect as per Specification of UPCL.
Dismantling of Old ACSR Conductor from following Existing LT Line including Re- rolling back its conductor,wire,clamp, insulator, any other wire or items etc.including stacking and transportation of material to the UPCL Central stores 2-40 Km.
3 Phase 4 wire
2 Phase 3 wire
1 Phase 2 wire
Laying,Stringing and sagging of LT A.B Cable size (3x120+1x95) including Fixing of Insulated Piercing Connector,Dead end Clamps With I Hook, Suspention Clamp,Holding Clamps, etc. complete in all respect as per Specification of UPCL.
Laying and Fixing Insulated Cable 4x25 sq mm insulated lead.
Fixing of L.T. Distribution Box in all respect.
Labour Charges of Disconnection & Re-Connection of Single Phase L.T.Consumer Service Connection.
Labour Charges of Disconnection & Re-Connection of Three Phase L.T.Consumer Service Connection.
UTTARANCHAL ENTERPRISES
M J ASSOCIATES
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .