Loading…
Loading…
Tender Value
₹14.3 L
EMD Value
₹28,560
Closing Date
31 Aug 2026, 4:00 pm7d left
Cheif Executive Officer, SJDA
Near Passport Seva Laghu Kendra, Himanchal Vihar, Matigara, Pin 734010
Supply, Installation, Testing and Commissioning of EV Charging Infrastructure for Electric Vehicle including all accessories and allied works for Parking area at Mela Ground, Kanchanjungha Stadium
2026_SJDA_1037806_1
NIT NO. 039/ ENGG/ ELECT/ 2026-27 OF SJDA
Open Tender
Electrical Work/ Equipment
Percentage
30 days
Siliguri
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹28,560
Yes
13 Aug 2026
13 Aug 2026
3 Sept 2026
13 Aug 2026
31 Aug 2026
13 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Light EV DC Charger (Mode 4) Power Level 1: Up to 7 kW, Input power supply: 1phase 230 +10% Volt/3phase 415 Volt, Frequency: 50 Hz +/-5%, output supply: 12/24 Volt DC. Operational temperature range : -25 to 55 0C (outdoor), -5 to 55 0C (Indoor), RH upto 95%, Charging Device as per IS-17017-25, EV-EVSE Communication:IS-17017-25, one Charge Point Plug/ Socket as per IS-60309 and IS-17017-2, Vehicle Inlet/ Connector As per EV manufacturer, suitable for 2
Wheelers and 4 wheelers. Indoor use: at least IP42;
Outdoor use: at least IP54. Mechanical Strength
:protection of the external enclosure against
mechanical impact shall be IK08 according to IEC
62262.O/L,S/C protection. Insulation Resistance > 1
M Ω. Cable Length: 7.5 m. RCD having a rated
residual operating current not exceeding 30 mA; Separate RCD for multiple outputs. Telecommunication port of the EV supply equipment according to IS 13252 (Part 1) : 2010. OCPP(Open charge point protocol) 1.6J upgradable to ocpp 2.0. Device Should follow 17017 series of IS codes in general and the installation of the system shall comply with relevant IS Codes. | 1 | Each | 3,50,914 | ₹3,50,914 |
| 2 | Parkbay DC Charger (Mode-3) Power Level 2: Normal
Power ~24KW and above, 3 phase 415VAC(-40% to
+20%), Frequency:50 Hz +/-5%, output supply: DC
12/24 Volt, Operational temperature range : -25 to 55
0C (outdoor), -5 to 55 0C (Indoor), RH upto 95%,
Charging Device as per Device/protocol: IS-17017-23,
EV-EVSE Communication as per IS-17017-24, ISO
15118, Infrastructure Socket as per IS-17017-2-2/3,
Vehicle Connector as per IS-17017-2-3 Vehicle Inlet/
Connector As per EV manufacturer, suitable for 4
wheelers. Indoor use: at least IP42; Outdoor use: at
least IP54. Mechanical Strength: protection of the
external enclosure against mechanical impact shall be
IK08 according to IEC 62262. O/L,S/C protection.
Insulation Resistance > 1 M Ω. Cable Length: 7.5 m.
RCD having a rated residual operating current not
exceeding 30 mA; Separate RCD for multiple outputs. Telecommunication port of the EV supply equipment
according to IS 13252 (Part 1) : 2010. OCPP (Open charge point protocol) 1.6J upgradable to
ocpp 2.0. Device Should follow 17017 series of IS
codes in general and the installation of the system
shall comply with relevant IS Codes. | 1 | Each | 8,88,982 | ₹8,88,982 |
| 3 | Wiring for circuit/ submain wiring along with earth wire
with the following sizes of FRLS/HFFR PVC insulated
copper conductor, single core cable in surface/
recessed steel conduit as required. : 4 X 6 sq. mm + 2 X 6 sq. mm earth wire | 45 | RM | 1,001 | ₹45,045 |
| 4 | Supplying & Erection of mini size feeder pillar box of Size (918 x 561 x 382 mm) made up of 2 mm thick MS Plate along with suitable M.S. Angle. The P.B. have double hinge door at the front & back with suitable locking arrangement. The box will be painted by 2 cores of aluminiam paint over 1 coat of red oxide paint. Suitable arrangement should be provided for fixing of Timer unit, fuse unit & other accessories. Leg of the pillar box will be 900 mm in length by made up of (35 x 35 x 3 mm MS Angle with suitable base Plate. Legs of the Pillar box will be erected at 300 mm below the ground level with cement concrete (6:3:1). Rest portion coverd by 5" Brick Wall with plastering & net cement & bottom portion filled with silver sand as drawing & direction of E.I.C | 1 | Each | 8,405.77 | ₹8,405.77 |
| 5 | Supplying & fixing sheetmetal (16SWG) Iron Clad Busbar chambers on angle ironframe on wall, incl. Earthing attachment and paintingas required–(As per Drawing no. 470 of PWDSpecification Book – May 1991) : Cu 4 bars 415 V, 100/125 A | 2 | Set | 3,376.8 | ₹6,753.6 |
| 6 | Supplying and fixing 415V Four Pole MCCB of
Breaking capacity 25kA/35kA with fixed thermal
and fixed magnetic /adjustable thermal and fixed
magnetic setting inexisting DBs / enclosureand
necessary connection: 63 A (Make: Legrand) | 2 | Each | 9,017.12 | ₹18,034.24 |
| 7 | Earthing with copper earth plate 600 mm X 600 mm X
3 mm thick including accessories, and providing
masonry enclosure with cover plate having locking
arrangement and watering pipe of 2.7 Meter long etc.
with charcoal/ coke and salt as required. | 4 | Each | 15,004 | ₹60,016 |
| 8 | Providing and fixing 25 mm X 5 mm copper strip on
surface or in recess for connections etc. as required. | 40 | Meter | 1,246 | ₹49,840 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.01 MB
BOQ_2549416.xls
BOQ • 0.33 MB
Form_No_2911.pdf
Additional Documents • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].