Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹97.8 LAccepted-AOC | L1 | Accepted-AOC Lowest Bid Accepted | |
| 2 | L2₹1.2 Cr+₹17.9 L (18.2%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | L2 | Rejected-Finance Not Being Lowest Bidder | |
| 3 | L3₹1.2 Cr+₹22.7 L (23.2%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest Bidder | |
| 4 | L4₹1.3 Cr+₹30.9 L (31.5%)Rejected-Finance DOOR NO 50 01 56 9 FLAT NO 9 SURYA TOWERS ASR NAGAR SEETHAMMADHARA NE VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | L4 | Rejected-Finance Not Being Lowest Bidder | |
| 5 | L5₹1.4 Cr+₹39.9 L (40.8%)Rejected-Finance | L5 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹1.2 Cr
EMD Value
₹1.9 L
Closing Date
3 Feb 2022, 6:00 pmClosed
Shri VK Tiwari, IDSE, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
Demolition and Reconstruction of MT Accn at HQ FOCEF, Naval Dockyard, Visakhapatnam
2021_MES_498401_1
82206 / E8
Open Tender
Civil Works
Lump-sum
270 days
Visakhapatnam
Class B Category a i
11 documents required · 11 mandatory
₹1,000
Garrison Engineer Naval Base
₹1.9 L
Yes
28 Feb 2022
31 Dec 2021
8 Feb 2022
31 Dec 2021
3 Feb 2022
27 Jan 2022
31 Dec 2021 - 7 Jan 2022
Amount
Schedule "A" Part – I to Schedule "A" Part – XII: Note: Schedule "A" Part – I to Part – XII are Prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lumpsum price worked out by the contractor for "Building & Structure", as listed in Schedule "A" Part – I on Serial Page No. 21[R]
Lumpsum price worked out by the contractor for "Pile foundation", as listed in Schedule "A" Part – II on Serial Page No. 22[R]
Lumpsum price worked out by the contractor for "Demolition/ Dismantling/ Taking down", as listed in Schedule "A" Part – III on Serial Page No. 23.
Lumpsum price worked out by the contractor for "Internal water supply", as listed in Schedule "A" Part – IV on Serial Page No. 24[R]
Lumpsum price worked out by the contractor for "Internal electrification", as listed in Schedule "A" Part – V on Serial Page No. 25[R]
Lumpsum price worked out by the contractor for "Earthwork and Excavation ", as listed in Schedule "A" Part – VI on Serial Page No. 26[R]
Lumpsum price worked out by the contractor for "Area drainage", as listed in Schedule "A" Part – VII on Serial Page No. 27.
Lumpsum price worked out by the contractor for "Sewage disposal", as listed in Schedule "A" Part – VIII on Serial Page No. 29.
Lumpsum price worked out by the contractor for "External water supply", as listed in Schedule "A" Part – IX on Serial Page No. 30.
Lumpsum price worked out by the contractor for "External electrification", as listed in Schedule "A" Part – X on Serial Page No. 31[R]
Lumpsum price worked out by the contractor for "Lightning protection", as listed in Schedule "A" Part – XI on Serial Page No. 32.
Lumpsum price worked out by the contractor for "Water Cooler", as listed in Schedule "A" Part – XII on Serial Page No. 33.
Schedule "A" Part – XIII: [Miscellaneous Items] [Pile foundation, Demolition/ Dismantling/ Taking down, Internal Water Supply, Internal Electrification, External Water Supply, External Electrification, Lightning protection]:
PILE FOUNDATION
Boring holes for bored cast–in–situ piles of 450mm dia in any strata except hard rock using Hydraulic Rotary Rig/ DMC method including getting out and disposal of spoil out side MD land to a distance exceeding 5.0km but not exceeding 10.0km complete all as specified and as directed. Notes: [a] Truck mounted Rotary / TMRT / Tubewell boring Machine shall not be used. [b] The rate quoted shall be deemed to be inclusive of the cost for shifting of Rigs as many times as required. [c] The rate quoted shall be deemed to be inclusive of the cost of Bentonite as required at site. [d] All tanks and connected channels made for Bentonite circulation process shall be made good by filling approved moorum including clearing all Bentonite cakes and the rate quoted shall be deemed to include for this provision also. [e] RCC and Reinforcement bars shall be measured and paid seperately.
Boring holes for bored cast–in–situ piles of 450mm dia in hard rock using Hydraulic Rotary Rig/ DMC method including getting out and disposal of spoil out side MD land to a distance exceeding 5.0km but not exceeding 10.0km complete all as specified and as directed. Notes: [a] Truck mounted Rotary / TMRT / Tubewell boring Machine shall not be used. [b] The rate quoted shall be deemed to be inclusive of the cost for shifting of Rigs as many times as required. [c] RCC and Reinforcement bars shall be measured and paid seperately.
M&L for providing mild steel lining pipes, not less than 6mm thick, conforming to Grade E-250, Quality B, suitable for 450mm nominal dia bored cast in situ concrete piles, driven upto a depth as directed by the Engineer-in-charge including provision of necessary stiffeners, driving shoe, etc. with continuous welding and painting two coats with epoxy based anticorrosive paint over a coat of primer all as specified and as directed. Notes: [a] The MS lining pipe shall be cut and removed upto Cut-Off level from the the top and the cost of the salvage value of material so removed shall be deemed to included in the rate quoted for this item and no extra claim shall be admissible on this account. [b] The depth of MS lining pipe shall be as decided by the Engineer-in-charge as per site requirement and based on the laboratory test results of Bailer samples from bore hole of piles which is final and binding.
Chipping out laitance concrete upto a maximum of 1m above cut off level of pile including disposal of debris up to a distance of 50m complete all as specified and as directed.
Carrying out Initial Load Test on 450mm dia bored cast–in–situ piles as per IS – 2911 [Part – IV] complete all as specified and as directed.
Carrying out Routine Load Test on 450mm dia bored cast–in–situ piles as per IS – 2911 [Part – IV] complete all as specified and as directed.
Carrying out Low Strain Integrity Test on 450mm dia bored cast–in–situ piles including analysing the results as per IS – 14893 & ASTM D 5882 complete all as specified and as directed.
DEMOLITION/ DISMANTLING/ TAKING DOWN
Dismantling of existing Rolling Shutters of any type/ any size and of any thickness of lathing including top cover, anchoring rod, hasp and staple including guide channel, hold fast, gear set & wheelcomplete all as specified and as directed.
Taking down carefully submain wiring of any description and size complete including wooden battens / conduits / casing capping and making good the disturbed surfaces all as per existing complete all as specified and as directed.
Taking down of MCB DB, SPN / TPN Enclosure including MCBs etc of any description and any capacity and making good the disturbed surfaces all as per existing complete all as specified and as directed.
INTERNAL WATER SUPPLY
S & F 15mm bore Two way Bib Taps, brass, Chromium Plated, screwed for iron pipe and fixed complete all as specified and as directed.
INTERNAL ELECTRIFICATION
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories, concealed in Walls / Roofs / Floors / Ceiling etc. and provision of Modular Type switch Box made out of 2mm thick GI Sheet of suitable size flush mounted with walls and Modular type white cover plate with grid Frame for housing Modular Type Switches, Sockets and Regulators etc. including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified and as directed.
All as per Serial Item No. 24 above but One 3 Pin Socket Outlet 6 Amps on Independent Board complete all as specified and as directed.
All as per Serial Item No. 24 above but one Power Point 16 Amps on independent board, with 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
All as per Serial Item No. 24 above but one AC/ Geyser outlet point on independent board, with 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
M & L for Sub main wiring with 2 runs of 6 Sq.mm, Single Core PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 3 runs of 6 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit
M & L for Sub main wiring with 2 runs of 2.5 Sq.mm, Single Core PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 3 runs of 2.5 Sq.mm & one run of 20 mm dia PVC Conduit will be measured as one unit
S&F Telephone Jack with shutter, 2 line, PVC/ polycarbonate body, white, modular type, 1 module, with metal box and modular cover plate and frame all as specified and as directed.
S&F TV socket outlet, PVC/ polycarbonate body, white, modular type, 1 module, with metal box and modular cover plate and frame all as specified and as directed.
S&F Computer RJ-45 Modem Jack with shutter, modular type, 2 module, with metal box and modular cover plate and frame all as specified and as directed.
S&F Distribution Board, Vertical type, TPN, 4 Way, 415 Volts, Double Door, suitable for MCCB 125A incomer IP 54 protection, with rated bus bars including connecting up, testing and commissioning complete all as specified and as directed. Note: MCCB/ MCB shall be measured and paid separately.
S & F Energy efficient & Long life Street Light Luminaire of not less than 3000 Lumens output, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power COB LED's as light source, electronic driver including GI Bracket made out of 32 mm bore GI Tube, Medium Grade of size not exceeding 1.50 m in length and bent to shape required and fixed with 2 Nos of Pole fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of aluminium paint over a coat of primer red oxide zinc chrome primer and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F Square recessed mounted Flat Panel LED Ceiling Light suitable for fixing in 2' X 2' Grid False Ceiling of not less than 3600 Lumens output, 5700 K, with PMMA diffuser for soft-light and glare free symmetrical illumination with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F Surface & wall mounted Energy efficient LED Tube Light Fitting of not less than 2000 Lumens output, 5700 K of cool white, with box type extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F Exhaust Fan, 300mm Sweep, 1400 RPM, Metal Body, Heavy Duty, with Double Ball Bearing, Conforming to IS - 2312, ISI Marked, suitable for operation on Single Phase, 240 Volts, AC, 50 Hz, including Louvers Shutter/ Grill, BEE 5 Star Rated and of approved colour including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed.
S & F Energy efficient, Low Noise, Ceiling Fan, 1200mm Sweep, BEE 5 Star Rated, with BLDC Motor, Copper Wound, 350 RPM, with Double Ball Bearing, Conforming to IS - 373, ISI Marked, suitable for operation on Single Phase, 240 Volts, AC, 50Hz, of approved colour including Down Rod, Canopies, 3 Nos. Blades, Shackles, Safety Rope, Hanging Clamps, Bushes and having P.F >0.94, Service Value >6.5, Air Delivery >215 CMM, Power Consumption less than 35 Watt, THD less than 5% with speed control by Electronic Regulator including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed.
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. of any description complete all as specified and as directed.
EXTERNAL WATER SUPPLY
M & L for Cutting existing 250mm bore CI/ DI Water Mains in situ and providing 80mm bore branch connection with and including 250 X 250 X 80 mm CI/ DI reducer Tee and necessary Specials complete all as specified and as directed.
EXTERNAL ELECTRIFICATION
M&L for trenchless lateral drilling of bore at a depth not exceeding 1 m below the road, monitoring using ultra sound technique suitable for drawing and including 150 mm bore 6 Kg/sqm heavy duty HDPE pipe in suitable lengths all as per site requirement and as directed.
LIGHTNING PROTECTION
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 25 X 4mm GI Strip [Earth Lead] and GI pipe 40 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed.
S & F Test Point Terminal Box of size 200 X 100 X 100mm made out of 2mm thick hot dip galvanised sheet, drilled and screwed including 6 Nos 15mm long hexagonal head screws complete all as specified and as directed.
SREE CONSTRUCTIONS
CIVILEC ENGINEERING WORKS
SREE VIJAYALAKSHMI ENTERPRISES
HARSHITHA INFRA
GAGANSRI INFRA
SRI SURYA PROJECTS
SAI KRISHNA ASSOCIATES
SOUTHERN BUILDERS
ANIL KUMAR BISWAL
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .