| 1 | L1₹13.8 LAccepted-AOC | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER | |
| 2 | L2₹14.9 L+₹1.1 L (7.65%)Rejected-AOC AMBEDKAR PARK AND RAWAT PG HOUSE WARD NO 10 KHASRA NO 2435 DEHRADUN UTTARAKHAND 248 140 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248140 | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 3 | L3₹17.4 L+₹3.5 L (25.5%)Rejected-AOC | L3 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 4 | L4₹18.1 L+₹4.3 L (30.8%)Rejected-AOC SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | L4 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 5 | Rejected-Technical RZF 498 MG MARG RAJ NAGAR II PALAM DELHI CANTT 110077 | NEW DELHI | DELHI | 110077 | - | Rejected-Technical Not Verfied |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
17 Feb 2024, 6:00 pmClosed
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
PROVN OF 63 KVA TRANSFORMER AND ASSOCIATED PANELS, WIRING AND EARTHING AT PHYSICAL AND ENVIRONMENTAL LAB AND PROVN OF 10 NOS CHEMICAL EARTHING AT TECH AREA OF CQA (I) UNDER GE (I) RND DEHRADUN
2024_MES_638299_1
GE(I)RND/9321/E8/23-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Dehradun
Class E Category b (ii) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 and 1.5 of section of Part I of MES Manual on contracts-2020 as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
Yes
GE I RND DEHRADUN
₹38,000
Yes
27 Feb 2024
19 Jan 2024
19 Feb 2024
19 Jan 2024
17 Feb 2024
5 Feb 2024
19 Jan 2024 - 5 Feb 2024
Amount
Supplying,erecting and fixing of steel tubular swaged pole 410 SP-55 (11 metre long),in true vertical position complete conforming to IS : 2713 (Part-I & III) 1980 with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole with and including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole finished with two coat of aluminum paint over and including one coat of red oxide primer complete, all as specified and directed. Note :- Earthwork, cement concrete in foundation, coping, cross arms will be measured and paid separately under relevant items of BOQ.
Supply and fixing of steel & iron items from poles i.e cross arms, bracing, supports, clamps and back plates etc. including nuts & bolts complete and Supply & fixing cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts & bolts , washers , welding bending cold or hot , drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide primer ccomplete, all as specified and directed.
Supply, fixing, commissioning & testing of distribution class lighting arrestor of rating 12 KV capacity and 10 KA NDC(Peak) confirming to to IEC-99.4 including brackets, clamps, bolts, nuts and washers complete, all as specified and directed.
Supply , fixing commissioning & testing of outdoor gang operated switch air break tilting type of current rating up to 200 Amps , triple pole each pole consisting of galvanized steel base. HT insulators as per IS, consisting of twelve insulator (3 insulators in each phase and one each for DO fuse), non ferrous knife and spray loaded contacts, arcing horns of adequate section to break magnetizing current of the transformers adequate lenth of GI pipe for phase separation, adequate length of GI pipe 25 mm dia light grade,for operation from ground level and operating handle with locking arrangement complete in both OFF & ON positions. All ferrous part hot dripped galvanized and non ferrous heavily tinned to with stand weather and suitable for vertical mounting 11000 volt 200 Amp current rating complete, all as specified and directed.
Supply, fixing, commissioning & testing of out door transformer 63 KVA capacity copper wound, three phase, step-down hermatically sealed, 11000/433 Volts at no load, oil immersed naturally cooled, corrugated wall design with external coolling tubes/fins core type, Delta connection on primary (HV side) in accordance with vector group DY-11 with neutral brought on secondary (LV side) and having tappings at + 2.5, + 5.0%, + 7.5% be changed by means of hand operated "OFF LOAD" tap changer gear complete, mounted on suitable size of PCC plate form as per manufacturer NORMS/ Latest IS standard IS:2026, IS : 1180, IS:649, IS: 12444, IS: 335, including testing and comprising with followings :-
(a) HT bushing suitable for 11 KV complete with all accessories -03 nos. (b) LT bushing suitable for 1100 V complete with all accessories -04 nos. (c) Oil conservator with filler type drain valve and oil level gauge. (d) Dehydrating breather with first fill dehydrating agent. (e) Expiosive vent. (f) Thermometer pocket on tank cover. (g) One number 100mm dial type thermometer, vapour pressure type, having range 0-120 degree centigrade with maximum reading pointer, Max. Temperature indicator and resting device. (h) Rating plate with terminal marking. (i) Two Nos, earting terminals on tank and cover to facilitable fixing of 32mm x6mm strip. (j) Oil level gauge. (k) Oil drain filter valve. (l) Lifting lugs. (m) Oil filter hole with cap/plug with connection complete. (n) Air release valve plug. (o) Four plain solid cast steel detachable rollers. (p) First fill of fresh trams former oil conforming to relevant IS and tested upto 60 KV dielectric strength complete, all as specified and directed. Note :- PCC Plate form will be measured and paid separately under relevant items of BOQ.
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. including removing cable protection covers/ bricks complete, all as specified and directed.
Excavation in trenches in any type of soil t exceeding 1.5 metre deep not exceeding 3.00 metre deep not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. including removing cable protection covers/ bricks complete, all as specified and directed.
M&L for Returning, filling in, including spreading leveling, watering and well ramming the excavated soil in layers not exceeding 25 cm thick complete, all as specified and directed
M&L for Removal of surplus excavated soil to a distance not exceeding 50 Mtr distance and depositing as directed at a level not exceeding 1.5 mtr above the starting point complete, all as specified and directed
Material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches/ducts for cable protection complete, all as specified and directed (NOTE : Thickness after punning shall be measured for payment)
Supplying & Laying un-reinforced pre cast flat concrete cable protection cover of class HV, type I, size 300mm x 180mm x 40mm, factory made complete, all as specified and directed.
Supplying & Laying un-reinforced pre cast flat concrete cable protection cover of Class LV, Type I, flat, size 250mm x 150mm x 40mm complete, all as specified and directed.
Supplying, laying & jointing of 80 mm boreGI water tubing light grade pipe as in sleeving etc laid in trenches /road/ ducts etc complete, all as specified and directed. MAKE : TATA/JINDAL/TT SWASTIK
Supplying, Laying, testing and commissioning of XLPE insulated, PVC sheathed (heavy duty) armoured shielded cable with aluminium conductor for working voltage upto 11KV (Earthed) of size 3 core95sq mm ,conforming to IS 7098 Part-II amended upto date complete, having cross sectional area under mentioned size of cables laid in trenches/fixed on pole/wall / passed through pipe including making necessary connection with VCB/2 pole structure etc.complete, all as specified and directed. Make:Havells/CCI/ICL/GLOSTER/Incab/ Nicco/Polycab/Plaza) (NOTE: Earth work, sand cushioning, PCC cover,GI pipe and clamps for holding cables shall be measured and paid separately )
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured aluminium conductor cable of sixe 95sq mm complete, all as specified and directed
Supply and fix cable jointing kit for 1.1 KV grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3.5core XLPE, armoured aluminium conductor cable of sixe 95sq mm complete, all as specified and directed
Supplying, Laying, testing and commissioning of XLPE insulated,IS 7098 (Part-I)-1988 marked screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 1100V grade cross section area of size 3.5 core95sq mmcables laid in trenches/fixed on pole/wall / passed through pipe including making necessary connection, with busbar/MCCB/DB's & testing complete, all as specified and directed Make:Havells/CCI/ICL/GLOSTER/Incab/Nicco/Polycab/Plaza) (NOTE: Earth work, sand cushioning, shall be measured and paid separately )
M&L in door type LT cubical pannel board outdoor type, front and rear openning with dust proof vermin proof made of 3.15 mm thick CRCA sheet steel factory made CPRI approved suitable for operation on 415 volts, 50 Hz AC supply conforming to IP-66 including suitable size of four pole aluminium bus bar complete with frame for mounting of panel 45 cm above the ground level, made out of 50x50x6mm thick and grouting by providing PCC 1:3:6 type C-1, using 20 mm grade crushed stone aggregate and painting with spray painting with seven tank process by using superior quality paint including provision of the following items (Make: L&T/ ABB / Shalabh / Advance Tricolite Adlac ) (a) MCCB 4 pole adjustable and thermal magnetic setting, 100 Amp, 415 Volts, 25 KA-01 No (Incoming) (b) MCCB 4 pole Fixed type, 63 Amp, 415 Volts, 25 KA -02 Nos (outgoing) for outgoing STP. (c) MCCB 4 pole fixed type, 40 Amps, 415 Volts, 16 KA-01 Nos (outgoing) spare (d) On load changeover switch, 100 Amps, 415 V, 4 pole-01 Nos (e) Aluminium bus bars sleeve insulated 200 Amps capacity TPN mounted on expoxy insulators-01 Set (f) LED indicator lamp RYB (Set of 3) - 01 Set (g) Digital voltmeter 0-500 V range 96 x 96 sqmm size within in built VSS - 01 No (h) Digital ammeter 0-200 Amps range 96 x 96 sqmm size with CTs and in built ASS-01 No (j) Internal wiring of the panel board with single core copper cable PVC insiulated of suitable size and control fuses. (k) Cable entry glands and two Nos earthing terminals. (l) Interconnection of busbar and MCCB with suitable size of copper cable and fixing material and color coat including PVC sleeves etc.
Earthing complete with galvanised MS earth plate electrode 600x600x6mm burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5mtr below normal ground level connected to and including copper earth strip 32x6 mm by means of bolts ,nuts,check nuts and washers of galvanised iron incl PCC pit in PCC1:2:4 type B-I, Angle iron 40x40x3mm frame, pit in PCC 1:2:4 type B-I cover 40mm reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle, excavation and earth work in any type of soil ,charcoal dust and salt light grade GI watering pipe 15 mm bore with funnel and wiremesh and medium grade GI protection pipe 40 mm bore 5 Mtr long and earth wire upto main earthing of pole complete all as shown in electrical plate No 5 of MES Sch 191 Part-I complete all as specified and as directed.
Earthing complete with Copper earth plate electrode 600x600x3.15mm burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5mtr below normal ground level connected to and including copper earth strip 25x3 mm by means of bolts ,nuts,check nuts and washers of galvanised iron incl PCC pit in PCC1:2:4 type B-i ,Angle iron 40x40x3mm frame, pit in PCC 1:2:4 type B-I cover 40mm reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil ,charcoal dust and salt light grade GI watering pipe 40 mm bore with funnel and wiremesh and medium grade GI protection pipe 15mm bore 5 Mtr long and earth wire upto main earthing of pole complete all as shown in electrical plate No 5 of MES Sch 191 Part-I complete all as specified and diected.
M&L for PCC 1:4:8 type (nominal mix) D-2 with 40 mm graded crushed stone aggregates as in foundation filling land mass concrete for poles and stay/installation paths & near feeder pillar/LT panel, including form work, fair finishing to exposed surface complete all as specified and as directed.
M&L for PCC 1:2:4 type (nominal mix) B-2 using 40 mm graded crushed stone aggregates as in plate-form coping of pole and the like complete including weather slightly rounded or chamfered angles and throaty includinf use of form work complete, all as specified and directed.
M&L for PCC 1:3:6 type (nominal mix) C-2 using 40 mm graded crushed stone aggregates as in foundation filling land mass concrete for pole and stay/ installation paths complete, all as specified and directed.
Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and diected.
Supply and fix Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts,bolts, washers and welding in two halves made to shape to suit thecross section of the pole complete all as specified and directed.
Supply and fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed.
Chemical Earthing with copper pipe electrode 3.0 M long having outer pipe dia 50mm & inner pipe dia 44mm duly filled with highly conductive and anti corrosive compound of required quantity having chemical compostion Bentonite 40%, copper sulphate 20%, Gypsom 5%, Graphite 10%, Alum 5%, Zinc sulphate 10%, Aluminium sulphate 10% buried in ground by digging a bore of 150mm dia surrounded by soil friendly backfill compound non soluble in water including connection with Copper earth strip 20x3mm upto 7 meter length, making PCC pit of size 0.3mx0.3mx0.3m (inner size) in mix 1:3:6 type CI with RCC 1:2:4 type B-1, 40mm thick cover reinforced with 6mm dia MS bars 3 Nos both ways with lifting hook made out of 8mm dia bar and testing on completion to acheive value not more than 0.5 ohm complete all as specified and directed.
Copper strip 32 x 6mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and diected.
Supply & fix Test point terminal block made out of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 Nos, 8mm dia 25mm long hexagonal head screws complete all as specified and directed.
S.K ASSOCIATE
shivrefrigeration
JS CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .