| 1.00 | Supply of suitable oil immersed star delta starter ATS/stator rotor starter of standard make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS 8544- 1979 latest with upto date ammendments for squarrel cage motor mounted ( make to be specified by the tenders) mounted on pannel board with magnetic type cover load release and dashpit time lag under voltage release with initial oil filling as per the satisfaction of Engineer in charge. | 1 | Nos | 85,000 ₹85,000 | 87,000 ₹87,000 | 84,000 ₹84,000 Lowest |
| 2.00 | Providing MS sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with comprising and capable of mounting the following accessories with all internal electric connections. The drawing of pannel board shall be subject to approval of Engineer in charge. | 1 | Nos | 64,000 ₹64,000 | 65,000 ₹65,000 | 63,000 ₹63,000 Lowest |
| 2.01 | (a) Ammeter AC supply 100 mm Sqare type electric of AE/L&T make of 0-500 Amp range for 240 HP mptpr with selector switches confirming to BIS 1248-1983 latest with up to date ammendments. | 2 | Nos | - | - | - |
| 2.02 | (b) Voltmeter AC supply 100 mm Sqare type electric of AE/L&T make of 0-500 Amp range for 240 HP mptpr with selector switches confirming to BIS 4064-1978 latest with up to date ammendments. | 1 | Nos | - | - | - |
| 2.03 | (c ) ICTP switches 400 amps with HRC fuses of satndard/MEI/Kilburn/ L&T make and having 250 amp for the operational rating of motor as per BIS 4064-1978 latest with up to date ammendments immedadiatly after the power meter of HPSEB. | 2 | Set | - | - | - |
| 2.04 | (d) Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral confirming to BIS 8084-1976 and 11353- 1985 read with 5578-1985 all latest with upto date ammendments. | 1 | Nos | - | - | - |
| 2.05 | (e) MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in confirmong feeder for motor offered by the tenderer to BIS 2516 - 1985 latest with up to date ammendments with neytral linked under voltage release. | 1 | Nos | - | - | - |
| 2.06 | (f) 3 phase incating lamps complete with toggle switches for individual motors confirming to BIS 3452 part I & II latest with up to date ammendments. | 1 | Nos | - | - | - |
| 2.07 | (g) Earth leakage relay of recomeneded Havells/Standard make as per BIS-2516-1977 with up to date ammendments and of suitable range which should have control box, operating handle and trip/reset bush bitton on/off indicators, re-indicating of spring condition of the circuit breaker for over current protection. The ciecuit shoulld be equipped with magnet thermal release with metallic tape CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on /off nreaker load side. | 1 | Nos | - | - | - |
| 2.08 | (h) Hour run meter of reputed make of four digit capacity conforming to BIS - 722 ( latest edition)/ recommendations ( 0-9999 hrs). | 2 | Nos | - | - | - |
Tender Value
₹1.5 L
EMD Value
₹3,000
Closing Date
9 Jan 2026, 5:00 pmClosed
EE CHAUNTRA
CHAUNTRA
Restoration of rain damage of LWSS Makriri Lakhnot in GP Kuthera in Tehsil Joginder Nagar Distt Mandi HP SH Replacement of ATS starter and pannel for 50 HP motor at Basahi Jone Ladwan pump house
2025_HPIPH_124812_1
EE-CTR-10972-11022 dated 31.12.2025-5
Open Tender
Civil Works
Item Rate
90 days
Joginder Nagar
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
EE CHAUNTRA
₹3,000
28 Jan 2026
31 Dec 2025
12 Jan 2026
31 Dec 2025
9 Jan 2026
31 Dec 2025
Supply of suitable oil immersed star delta starter ATS/stator rotor starter of standard make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS 8544- 1979 latest with upto date ammendments for squarrel cage motor mounted ( make to be specified by the tenders) mounted on pannel board with magnetic type cover load release and dashpit time lag under voltage release with initial oil filling as per the satisfaction of Engineer in charge.
Providing MS sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with comprising and capable of mounting the following accessories with all internal electric connections. The drawing of pannel board shall be subject to approval of Engineer in charge.
(c ) ICTP switches 400 amps with HRC fuses of satndard/MEI/Kilburn/ L&T make and having 250 amp for the operational rating of motor as per BIS 4064-1978 latest with up to date ammendments immedadiatly after the power meter of HPSEB.
(d) Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral confirming to BIS 8084-1976 and 11353- 1985 read with 5578-1985 all latest with upto date ammendments.
(e) MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in confirmong feeder for motor offered by the tenderer to BIS 2516 - 1985 latest with up to date ammendments with neytral linked under voltage release.
(f) 3 phase incating lamps complete with toggle switches for individual motors confirming to BIS 3452 part I & II latest with up to date ammendments.
(g) Earth leakage relay of recomeneded Havells/Standard make as per BIS-2516-1977 with up to date ammendments and of suitable range which should have control box, operating handle and trip/reset bush bitton on/off indicators, re-indicating of spring condition of the circuit breaker for over current protection. The ciecuit shoulld be equipped with magnet thermal release with metallic tape CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on /off nreaker load side.
(h) Hour run meter of reputed make of four digit capacity conforming to BIS - 722 ( latest edition)/ recommendations ( 0-9999 hrs).
(i) Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing no volatge high voltage & overloading & phase voltage difference ( 380-440 volts).
(j) Change over switch of reputed make suitable capacity.
(k) Single phase preventor of reputed make & suitable capacity.
Errection testing and commissioning of all above offered equipts including head load carrarge.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.12 MB
BOQ_183649.xls
BOQ • 0.26 MB
02Form6.pdf
Tender Documents • 0.21 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .