Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance EN 62 7TH FLOOR SALTLAKE CITY KOLKATA SECTOR V WEST BENGAL 700091 | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical Not Meeting Eligibility Criteria |
| 5 | Rejected-Technical | Rejected-Technical Not Meeting Eligibility Criteria |
Tender Value
Refer Docs
EMD Value
₹90 L
Closing Date
29 Jul 2022, 10:00 amClosed
DIRECTOR GENERAL
DIRECTOR GENERAL NAVAL PROJECTS, NAVAL BASE POST, NAVAL BASE, VISAKHAPATNAM -14
SETTING UP OF POWER SUPPLY FACILITY FOR EAST SIDE JETTIES AT NAVAL DOCKYARD VISAKHAPATNAM
2022_NAVY_528456_1
DG/6500/DGNP(V)/GP2/TOKEN-01 OF 2022-23
Open Tender
Miscellaneous Goods
730 days
NAVAL DOCKYARD, VISAKHAPATNAM
AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹1,000
DGNP VISAKHAPATNAM
₹90 L
Yes
PD AND CWE EQPT 2, CONFERENCE HALL, DGNP, VISAKHAP
19 Sept 2022
4 Jun 2022
1 Aug 2022
4 Jun 2022
29 Jul 2022
8 Jul 2022
4 Jun 2022 - 11 Jun 2022
23 Jun 2022
ANNEXURE-1 (CIVIL SERVICES FOR MRS AREA) - Serials quoted in column 2 below refer to corresponding serials in the pdf doc "BOQSheetsAnnex1to20" uploaded alongwith the tender.
Site Clearance (Sl.No-1 to 2)
Cutting Down Trees (Sl.No-3 to 4)
Excavation (Sl.No-5 to 10)
Anti Termite Treatment (Sl.No-11 to 15)
Pile Works(Sl.No-16 to 19)
Plain Cement Concrete (Sl.No-20 to 25)
Reinforcement Cement Concrete (Sl.No-26 to 27)
Form Work (Sl.No-28 to 33)
Reinforcement steel - MT Steel bars of Grade Fe 500. (Sl.No-34 to 35)
Masonry Work (Sl.No-36 to 38)
Plastering (Sl.No-39 to 41)
Painting (Sl.No-42 to 46)
Joinery (Sl.No-47 to 59)
Glazing (Sl.No-60)
Flooring (Sl.No-61 to 63)
Skirting (Sl.No-64 to 65)
Dadooing/Cladding (Sl.No-66,66.1 to 68)
TRANSFORMER, BPI, ISOLATAR
Excavation (Sl.No-69 to 73)
Plain Cement Concrete (Sl.No-74)
Reinforcement Cement Concrete (Sl.No-75)
Form Work (Sl.No-76)
Reinforcement steel - mt steel bars of grade fe 500. (Sl.No-77 to 80)
Dismantling (Sl.No-81 to 87)
Terrace Area Drainage Works (Sl.No-88 to 89)
ANNEXURE-2 (LIST OF LINE ITEMS FOR SUPPLY, INSTALLATION TESTING AND COMMISIONING OF ELECTRICAL WORKS IN MRS AREA FOR 132/11KV EQUIPMENTS WITH SPECIFICATION )
Design, Supply,Transportation,Storing,Loading,Unloading ,Handlling, Erection, Testing and Commissioning of 145KV, 31.5KA for 3 Sec outdoor type BUS POST INSULATORS to be mounted on complete Steel Structure for supporting the MOOSE conductor for Each Incoming Transformer bay as per Technical Specifications ,Tender Documents and as per the Condition of Contract . (Sl.No-1)
Design, Supply,Transportation,Storing,Loading,Unloading ,Handlling, Erection, Testing and Commissioning of 145kV, 3 phase, 1600A, 40 KA for 3 Sec Double Break Type Motor Operated Isolators with Single Earth Switch including Supporting Insulators for Isolators suitable for outdoor with Complete all accessories and with complete Steel Structure for Each Incoming Transformer bay as per Technical Specifications ,Tender Documents and as per the Condition of Contract. (Sl.No-2)
Design, Supply,Transportation,Storing,Loading,Unloading ,Handlling, Erection, Testing and Commissioning of 120kV, 10kA, Class-3 Station Class Zinc Oxide Gapless Type Lightning Arrestor complete with insulating Base and Surge Counter with all accessories complete as per Technical Specifications. (Sl.No-3)
Design, Supply,Transportation,Storing,Loading,Unloading ,Handlling, Erection, Testing and Commissioning of MOOSE ACSR Conductor Interconnecting between BPI, Isolator, LA and Transformer including all the Clamps and Connectors ,Nuts and Bolts with complete accessories suitable for the Respective Equipment. (Sl.No-4)
Design, Supply,Transportation,Storing,Loading,Unloading ,Handlling, Erection, Testing and Commissioning of the 1C x 630 sq.mm XLPE EHV Copper Cable to be laid on trays, built in trenches or through Hume pipes / GI pipes including supply of saddles, hardware and Consumables complete as per specifications. The Power Cable required between BPI, Isolator, LA and Transformer. (Sl.No-5)
Design, Supply,Transportation,Storing,Loading,Unloading ,Handlling, Erection, Testing and Commissioning of the 1C x 630 sq.mm XLPE EHV Copper Cable termination (Cold/Heat Shrinkable Type) Indoor/Outdoor Type including Cable Glanding, Lugs, ferrules, Ties and Cable Tags etc., including all accessories / consumables complete as per specifications. (Sl.No-6,6.1 to 6.2)
Design, Supply,Transportation,Storing,Loading,Unloading, Positioning ,Handlling, Erection, Testing and Commissioning of the NEW 132 KV / 11KV, 20/25 MVA, ONAN/ONAF, 3 phase, 50 HZ, Dyn11, Z = 10% with OLTC + 5% and -15% in steps of 1.25%, with RTCC, AVR, Mineral oil filled as per (IS 335) POWER TRANSFORMER with all fittings, accessories, associated equipment and mandatory space complete as per Technical Specifications and as per relevant IEC / IS Specifications including oil Filtaration, BDV, Cabling Complete. Note:- (a) All the Mandatory Spare Parts of the Transformer as mentioned in the Tender Documets Should be quoted by considering the Extended Warranty of 2Years on Transformer. (b) The Bidder shall quote including the Extended Warranty of 3Years of the Transformer. (Sl.No-7) A) to B)
The Power Transformer should be provided with Fire prevention and extinguishing system with NITROGEN INJECTION FIRE PROTECTION AND EXTINGUISHING system which should work on the " OIL DRAIN, NITROGEN INJECTION AND STIR" method. The system shall operate during internal fault in Transformer or External fire on Transformer which includes fire due to bursting of transformer bushing. The Fire Protection shall operate in Auto mode on receipt of minimum three positive feedback signals namely from relay or Fire detector or PRV or PRD or Buchholz relay complete with all requirements as per the specifications. (Sl.No-7) C)
MRS Earthing System. (Sl.No-8,8.1)
External Water Supply for Earth Pits and Earthing Strips (Sl.No-9, 9.1 to 9.7)
Design, Supply,Transportation,Storing,Loading,Unloading ,Handlling, Erection, Testing and Commissioning of the XLPE insulated screen PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty (Earthed) with standard aluminium conductor of 11kV(E) HT CABLE 3C x 400 sq.mm XLPE AL CABLE to be laid on trays, built in trenches or through Hume pipes / GI pipes/ Buried in Ground including supply of saddles, hardware and Consumables complete as per specifications. (For the interconnectivity between the Newly Installed 20/25 Transformer to the Existing MRS 11KV HT Panel and from the Existing MRS HT Panel to the 11KV,NEW HT PANEL LOCATED IN PROPOSED NEW BUILDING ) Note:- (a) The Bidder shall quote including the Extended Warranty of 3Years for the cable. (Sl.No-10)
Design, Supply,Transportation,Storing,Loading,Unloading ,Handlling, Erection, Testing and Commissioning of the 11kV(E) HT CABLE 3C x 400 sq.mm XLPE AL CABLE termination (Cold/Heat Shrinkable Type) Indoor/Outdoor Type including Cable Glanding, Lugs, ferrules, Ties and Cable Tags etc., including all accessories / consumables complete as per specifications. (Sl.No-11,11.1,11.2)
Design, Supply,Transportation,Storing,Loading,Unloading ,Handlling, Erection, Testing and Commissioning of the XLPE insulated screen PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty (Earthed) with standard aluminium conductor of 11kV(E) HT CABLE 3C x 240 sq.mm XLPE AL CABLE to be laid on trays, built in trenches or through Hume pipes / GI pipes including supply of saddles, hardware and Consumables complete as per specifications. (For the interconnectivity between the Newly HT PANEL and to the NEW APFC PANEL and from the APFC PANEL to the Capacitor Banks ) Note:- (a) The Bidder shall quote including the Extended Warranty of 3Years for the cable. (Sl.No-12)
Design, Supply,Transportation,Storing,Loading,Unloading ,Handlling, Erection, Testing and Commissioning of the 11kV(E) HT CABLE 3C x 240 sq.mm XLPE AL CABLE termination (Cold/Heat Shrinkable Type) Indoor/Outdoor Type including Cable Glanding, Lugs, ferrules, Ties and Cable Tags etc., including all accessories / consumables complete as per specifications. (Sl.No-13,13.1,13.2)
Design, Supply,Transportation,Storing,Loading,Unloading ,Handlling, Erection, Testing and Commissioning of the 11kV(E) CABLE Jointing Material (Cold/Heat Shrinkable Type) with complete accessories Suitable for 11KV ,3C x 240 to 400 sq.mm XLPE AL Cable as per the requirement and Tender specifications. (Sl.No-14)
Design, Supply,Transportation,Storing,Loading,Unloading ,Handlling, Erection, Testing and Commissioning of the Interconnecting control cabling between GIS and the Filed Equipment to be laid on trays, built in trenches or through Hume pipes / GI pipes including supply of saddles, hardware and Consumables complete as per specifications. The Control cables for 132KV and 11KV Side Equipments required between all equipments such as BPI ,Isolators ,LA’s / marshalling box / Relay and control panel / OLTC panel, Battery Charger and for complete wiring of the receiving control station to be laid in a proper manner. (Sl.No-15,15.1 to 15.5)
11KV, New HT Panel Located in Proposed New Building (Indoor Type) (Only Provision for Future Expandable Panel has to be provided for 2 No's of Spare Feeder (1VCB on B/S-1 and 1VCB on B/S-2.) (Sl.No-16)
Supply, Installation, Fixing, Testing and Commissioning of AUTOMATIC POWER FACTOR CONTROL PANEL for Auto/Manual Operation Mode Suitable for 3600 KVAR. (Sl.No-17)
Supply, Installation, Fixing, Testing and Commissioning of 3600 KVAR OUTDOOR CAPACITOR BANKS Including Reactors With following configuration:- 2x1200KVAR-1Set. 1X 600KVAR-1Set. 1X 400KVAR-1Set. 1x200KVAR-1Set. This should Include Complete Steel Structure ,Supports ,Saddles with all the Necessory accessories to do the complete Installation of the Outdoor Capacitor Banks as per Technical Specifications ,Tender Documents and as per the Condition of Contract . (Sl.No-18)
GENERAL ITEMS (Sl.No-19, 19.1 to 19.5)
Lightning Protection Material for Switchyard Area (Sl.No-20,20.1 , 20.2)
110V DC, 200 AH 55 Nos of 2 volt each Ni-Cd maintenance free battery Battery Bank including Boost and Float System and Battery Charger and Inter Connection Cable from Battery Bank to Chargers including ACDB and DCDB. (Sl.No-21,21.1,21.2)
AC DB's and DC DB's (Sl.No-22,22.1,22.1.1,22.1.2,22.2,22.2.1,22.2.2)
Power Cables (Sl.No-23,23.1 to 23.5)
SCADA Upgradation Works at Naval Dockyard MRS Area (Sl.No-24.1 to 24.11)
UPS/INVERTERS : (Sl.No-25,25.1)
PAYBACK LINE ITEMS OF ANNEXURES II
The Existing 10/16MVA, 132/11KV, Transformer with ONAN/ONAF with OLTC with all accesseris under live working condition at DGNP site Working from since : 2011. Make : CGL (Sl.No-27)
The existing LA 120KV ,10KA configuration working condition as on dated site Make : OBLUM (Sl.No-28)
Bus post insulator suitable for 132kv , 1C x 630sqmm Cu cable termination is in working condition. (Sl.No-29)
The following HT/LT Cable configuration or Any other Size of the cables a ) 1C x 630 sqmm Cu Screen cable 132KV b ) 11kv , 3C x 400 sqmm AL AYFY Cable c ) 11kv , 3C x 240 sqmm AL AYFY cable d ) 11kv , 3C x 185 sqmm AL AYFY cable e ) 11kv , 3C x 120 sqmm AL AYFY cable (Sl.No-30)
The Material like Electrical item like Conduits, wires,Switch board, Sockets DB's etc..Which are related to the Old MRS building accessories.(Scrap Item) (Sl.No-31)
ANNEXURE-3
List of line items for Dismantling /Taking Down, Handling, Receiving and Unloading of 132/11KV Equipment as directed in MRS area.
ANNEXURE-4
Cost Estimation for Internal Electrification Works for MRS Area Control Room
ANNEXURE-5
Lightning Protection System for MRS Area
ANNEXURE-6
Fire Alarm (Addressable) System & PA System for MRS Area
ANNEXURE-7 (CIVIL SERVICES FOR JRS AREA AND CIVIL WORKS FOR JRS CONTROL ROOM)
Site Clearance (Sl.No-1 to 2)
Cutting Down Trees (Sl.No-3 to 4)
Excavation (Sl.No-5 to 10)
Anti Termite Treatment (Sl.No-11 to 15)
Pile Works (Sl.No-16 to 19)
Plain Cement Concrete (Sl.No-20 to 25)
Reinforcement Cement Concrete (Sl.No-26 to 27)
Form Work (Sl.No-28 to 33)
Reinforcement Steel - MT Steel Bars of Grade FE 500. (Sl.No-34 to 35)
Masonry Work (Sl.No-36 to 38)
Plastering (Sl.No-39 to 41)
Painting (Sl.No-42 to 46)
Joinery (Sl.No-47 to 59)
Glazing (Sl.No-60)
Flooring (Sl.No-61 to 63)
Skirting (Sl.No-64 to 65)
Dadooing/Cladding (Sl.No-66,66.1 to 68)
Nomenclature Board for JRS (Sl.No-69)
Area External Water Drains and Terrace Drain JRS (Sl.No-70 to 78)
ANNEXURE-8 (LIST OF LINE ITEMS FOR SUPPLY, INSTALLATION TESTING AND COMMISIONING OF ELECTRICAL WORKS IN JRS AREA FOR 11KV AND LT EQUIPMENTS WITH SPECIFICATION)
11KV, New 8Way VCB HT Panel-1 to VLM Jetty (Indoor Type) (As Per Option-1) (Sl.No-1)
11KV, New 6Way VCB HT Panel-2 to SSP Jetty (Indoor Type) (As Per Option-1) (Sl.No-2)
11KV, New 7Way VCB HT Panel-3 to to DLB and Incoming (Indoor Type) (As Per Option-1) (Sl.No-3)
Design, Supply,Transportation,Storing,Loading,Unloading ,Handlling, Erection, Testing and Commissioning of the 11kV(E) HT CABLE 3C x 400 sq.mm XLPE AL CABLE termination (Cold/Heat Shrinkable Type) including Cable Glanding, Lugs, ferrules, Ties and Cable Tags etc., including all accessories / consumables complete as per specifications. (For the interconnectivity between the Newly Installed HT PANEL Located in the New Building in MRS Area to the Jetty Area Incoming cable of HT Panels Like 11KV, NEW 7WAY VCB HT PANEL-1 TO VLM JETTY 11KV, NEW 6WAY VCB HT PANEL-2 TO SSP JETTY 11KV, NEW 7WAY VCB HT PANEL-3 TO DLB AND INCOMING ) (Sl.No-4)
Design, Supply,Transportation,Storing,Loading,Unloading ,Handlling, Erection, Testing and Commissioning of the 11kV(E) HT CABLE 3C x 400 sq.mm XLPE AL CABLE termination (Cold/Heat Shrinkable Type) Indoor/Outdoor Type including Cable Glanding, Lugs, ferrules, Ties and Cable Tags etc., including all accessories / consumables complete as per specifications. (Sl.No-5)
Design, Supply,Transportation,Storing,Loading,Unloading ,Handlling, Erection, Testing and Commissioning of the 11kV(E) CABLE Jointing Material (Cold/Heat Shrinkable Type) with complete accessories Suitable for 11KV ,3C x 240 to 400 sq.mm XLPE AL Cable as per the requirement and Tender specifications.(Sl.No-6)
Design, Supply,Transportation,Storing,Loading,Unloading ,Handlling, Erection, Testing and Commissioning of the Interconnecting control cabling between GIS and the Filed Equipment to be laid on trays, built in trenches or through Hume pipes / GI pipes including supply of saddles, hardware and Consumables complete as per specifications. The Control cables for 11KV Side and LT Side Equipments required between all equipments such as Relay and control panel / OLTC panel, Battery Charger and for complete wiring of the receiving control station to be laid in a proper manner.(Sl.No-7,7.1 to 7.5)
GENERAL ITEMS (Sl.No-8,8.1 to 8.5)
110V DC, 200 AH 55 Nos of 2 volt each Ni-Cd maintenance free battery Battery Bank including Boost and Float System and Battery Charger and Inter Connection Cable from Battery Bank to Chargers including ACDB and DCDB.(Sl.No-9,9.1,9.2)
AC DB's and DC DB's Supply, Erection, Fixing, Testing and Commissioning of the following distribution boards as per the requirement. 415V AC Distribution Board 110V DC Distribution Board (Sl.No-10,10.1.1,10.1.2,10.2,10.2.1,10.2.2)
Power Cables (Sl.No-11,11.1 to 11.5)
JRS Area Earthing System. (Sl.No-12 to 12.1)
External Water Supply for Earth Pits (Sl.No-13,13.1 to 13.4)
Design, Supply,Transportation,Storing,Loading,Unloading ,Positioning ,Handlling, Erection, Testing and Commissioning of the 11 KV/ 433V, 63KVA, AF, 3 phase, 50 HZ, Dyn11, Z = 2.5% with OLTC CAST RESIN DRY TYPE DISTRIBUTION TRANSFORMER with all fittings, accessories, associated equipment and mandatory space complete as per Technical Specifications and as per relevant IEC / IS Specifications including Cabling Complete.(Sl.No-14)
SCADA Works at Naval Dockyard JRS Area (Sl.No-15)
UPS/INVERTERS (Sl.No-16,16.1)
ANNEXURE-9
Cost Estimation for Internal Electrification Works for JRS Area Control Room
ANNEXURE-10
Lightning Protection System for JRS Area
ANNEXURE-11
Fire Alarm (Addressable )System & PA System for JRS Area
ANNEXURE-12
Internal Water Supply & Sewage Disposal Services for JRS Area
ANNEXURE-13 (RCC TRENCH)
Excavation (Sl.No-1 to 5)
Plain Cement Concrete (Sl.No-6)
Reinforcement Cement Concrete (Sl.No-7 to 22)
Inspection Chambers (Sl.No-23 to 37)
ANNEXURE-14
Compound Wall
ANNEXURE-15
BT Road
ANNEXURE-16
List of line items for Supply, Installation Testing and Commissioning of Electrical Works in JRS Area for 11KV and LT Equipments with specification
ANNEXURE-17
CCTV System for MRS Area
ANNEXURE-18
CCTV System for JRS Area
ANNEXURE-19
JRS Water Cooler-Internal PHE
ANNEXURE-20
Schedule of Credits for Civil Item of Dismantled Building
GUPTA POWER INFRASTRUCTURE LIMITED
SRI SAI LEELA ELECTRICAL PROJECTS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid