Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹23.9 LAccepted-AOC 1ST FLOOR BUILDING NO 49 176 SYAMA BUSINESS CENTRE NH BYPASS VYTTILA ERNAKULAM 682019 | ERNAKULAM | ERNAKULAM | KERALA | 682019 | ₹23.9 L | 1 | Accepted-AOC L1 |
| 2 | 2₹26.6 LRejected-AOC 1ST FLOOR JM BUILDING M DOS TECH SOLUTIONS ANAMIKA STREET CIVIL STATION CALICUT KOZHIKODE KERALA 673020 | KOZHIKODE | KERALA | 673020 | ₹26.6 L | 2 | Rejected-AOC L2 |
| 3 | 3₹28.7 LRejected-Finance 5 3205F 1ST FLOOR RAJEEVARI ARCADE UKS ROAD KOZHIKODE 673 001 | KOZHIKODE | KOZHIKODE | KERALA | 673001 | ₹28.7 L | 3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | M.DOS TECH SOLUTIONS L2 | Syama Dynamic IT Services Pvt.Ltd L1 | Xybo3 IT Solution L3 |
|---|---|---|---|---|---|---|
| 1.00 | 1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | 550 | metre | 76 ₹41,800 | 86.4 ₹47,520 | 70 ₹38,500 Lowest |
| 2.00 | 1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm | 225 | metre | 106 ₹23,850 Lowest | 129.6 ₹29,160 | 110 ₹24,750 |
| 3.00 | 1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm | 1,250 | metre | 67 ₹83,750 | 54 ₹67,500 Lowest | 90 ₹1,12,500 |
| 4.00 | 1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm | 870 | metre | 71 ₹61,770 | 60.75 ₹52,852.5 Lowest | 100 ₹87,000 |
| 5.00 | 1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch | 15 | each | 475 ₹7,125 | 94.5 ₹1,417.5 Lowest | 250 ₹3,750 |
| 6.00 | 1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet | 5 | each | 475 ₹2,375 | 148.5 ₹742.5 Lowest | 450 ₹2,250 |
| 7.00 | 1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) | 15 | each | 475 ₹7,125 | 209.25 ₹3,138.75 Lowest | 650 ₹9,750 |
| 8.00 | 1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in
recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps
modular switch, connection etc. as required. (For light plugs to be used in non residential
buildings). | 18 | each | 475 ₹8,550 | 380.7 ₹6,852.6 Lowest | 650 ₹11,700 |
| 9.00 | 1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable | 7,900 | metre | 51 ₹4,02,900 | 49.81 ₹3,93,538.5 Lowest | 53 ₹4,18,700 |
| 10.00 | 1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). | 50 | each | 475 ₹23,750 Lowest | 598.05 ₹29,902.5 | 1,000 ₹50,000 |
Tender Value
₹30.0 L
EMD Value
₹50,000
Closing Date
2 Sept 2024, 6:00 pmClosed
University Engineer
Office of the University Engineer Engineering Department University of Calicut Calicut University P O Malappuram District Kerala 673635
Providing Local Area Network connection to the rooms of research scholars at Womens hostel
2024_UoC_687507_1
D3/276216/E-Tender No.7/2023--24
Open Tender
Electrical Works
Item Rate
90 days
University of Calicut
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,950
Yes
₹50,000
Yes
19 Aug 2026
23 Aug 2024
4 Sept 2024
23 Aug 2024
2 Sept 2024
23 Aug 2024
Amount
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
od267384/2023_2024 : Supplying and fixing 19" double section wall mount 6U 500D Rack with all accessories and including fixing charges
od267385/2023_2024 : Supplying and fixing layer 2, 24 gigabit ethernet port with additional 2 combo gigabit (SF/copper) switch with slot.<br>
od267386/2023_2024 : Supplying and fixing fully loaded fibre patch panel (LIU) including complete fibre PiG Tails. etc completed.
od267387/2023_2024 : Supplying and fixing one Splicing Box with complete Splicing for the OFC .
od267388/2023_2024 : Supplying and fixing 24 port CAT 6 Jack panel fully loaded including termination (Proper numbering should be done)<br>
od267389/2023_2024 : Sup[plying and fixing of Cat 6 patch cord 1 mtr.<br>
od267390/2023_2024 : Supplying and fixing of Cat 6 patch cord 3 metre length<br>
od267391/2023_2024 : Supply and fixing surface mount box for fixing face plate.<br><br>
od267392/2023_2024 : Supplying and fixing Cat FACE PLATE and information outlet (Key stone)<br>
od267393/2023_2024 : Supply and drawing optic fibre cable 6 core.
od267394/2023_2024 : Supply and fixing optical patch cord (2 mtr) (SC to LC Duplex)<br>
od267395/2023_2024 : Supply and fixing fibre module - 1G multi mode<br>
od267396/2023_2024 : Supplying and fixing SC to SC patch cord
od267397/2023_2024 : Supplying and fixing LC to LC patch cord.
od267398/2023_2024 : Supplying and fixing media converter 10/100/1000(single mode single)
od267409/2023_2024 : Supply & laying of DWC pipe in the existing pit for UG cables<br>50/38 mm or nearest size.
od267410/2023_2024 : Cutting the floor/wall (Tile/Marble etc.) for laying 20 to 25 mm PVC pipe with minimum portion and fixing the same/similar pieces, in the required length after laying the same by using cement sand etc. by neatly
od267436/2023_2024 : Dismantling all local area network equipment's including in the network rack in sizes 6U, including removing of connected wire cables to upgrade the size of rack, ports and mounting boxes without any damage, if required, including necessary arrangements to relocate the existing 6 core OH fibre cable to another rack, splicing etc. complete. dismantled items should be brought back in to the electrical store.
od267438/2023_2024 : Supplying and fixing 19" double section wall mount 9U 500D Rack with all accessories and including fixing charges
od268528/2023_2024 : Supplying and fixing 19" double section wall mount 12U 500D rack with all accessories and including fixing charges.
od268533/2023_2024 : Supply & Laying of DWC pipe in Hard Soil 0.7 m below ground level including excavation. 50/38 mm or nearest size.
od270359/2023_2024 : Supply laying testing of 12 core single mode out door loose tube armoured 9/125μM OS2 type optical, low water peak fibre indoor/ outdoor rated with loose tube diameter 1.8mm (Normal) outer sheath : anti radent anti termite and UV HD polyethylene - back, overall cable Dimensions (Normal) : 10.0 ± 1mm,Mass normal 130 Kg/Km ± 10% Max. Tensile strength Short term : 3400N, Min. Crush resistance- 4200N/10cm, optical performance Max attenuation At 1310mm :0.35 db/km at 1550mm : 0.20db/km, RoHS compliant Make : Molex, Belden, panduit, Commscope.
M.DOS TECH SOLUTIONS
Xybo3 IT Solution
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1069736.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].