GE (AF) Halwara
GE (AF) Halwara
REPAIR / MAINT OF LT PANELS AND ALLIED WORKS IN OFFICER ENCLAVE AT AF STN HALWARA
2026_MES_799142_1
GE/HAL-77/2026-27
Open Tender
Civil Works
Item Rate
183 days
Halwara
As per cover 1
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Halwara
₹50,000
Yes
17 Nov 2026
17 Nov 2026
11 Dec 2026
17 Nov 2026
9 Dec 2026
2 Dec 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L in replacement for feeder pillers box factory made -out door type made out of MS sheet (CRCA) of thickness not less that 3 mm. of size 75 x 75 x 45 cm with aluminium bus bar strip 4 Nos of 250 Amps rated suitable for 1100 volt (LT) mounted on LT porcelain insulator front opening door two leaf braced with hinged, mounted on 4 Nos of angle iron 50x50 mm duly welded with box and grouted in PCC block of size 30cmx30cmx 15cm in concrete 1: 3 : 6. Top of box MS sheet duly bent in/slope, tapper with projection of 30 mm on all side, weather/vermin proof with high quality of rubber beeding on panel door, cable entry arrangements at bottom includes earthing terminals 2 Nos at both side and painted with two coats of smoke grey stove enameled paint over a primer coat including providing MCCB, 4 pole,fixed type 200 Amps, 36 KA rating-01 No, complete all as specified and directed. | 3 | Each | - | - |
| 2 | Supply, installation, testing and commissioning in replacement of LT panel board as pere IS 8632, made out of 3.15mm thick CRCA sheet, outdoor cubical type (double door) totally enclosed weather, dust and vermin proof with front and rear opening of 415 volots, 3 phase, 4 wire 50 Hz including internal wiring with copper conductor and two coats of synthetic enamel paint over a coat of red oxide primer including connecting all incoming and outgoing cable feeders with necessary cable glands, thimbles etc. The panel should have 4 No of angle iron base frame made of 40x40x6mm (60 cm long legs) fixed in ground including 30x30x30cm PCC 1:2:4 type B-1 using 20mm graded stone aggregates, finishing with cement plaster 15mm thick in cement mortar 1:4 and comprising of the following switchgear, accessories, complete all as specified and directed :-
(a) 04 strips of Aluminium bus bars with insulation colour sleeves of capacity 600 Amp fixed on PVC heat shrinkable insulator heavy duty.
(b) Volt meter 0-500 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch - 01 No
(c) Amp meter 0-300 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch with suitable size CTs - 01 No
(d) Indicator lamp LED type on all phases (R. Y. B.) -03 Nos
(e) MCCB 3 phase, 415 volts, 4 pole 36 KA, 400 Amp -01 No (incoming)
(f) MCCB 3 phase, 415 volts, 4 pole 25 KA, 100 Amp -01 Nos (outgoing)
(j) MCCB 3 phase, 415 volts, 4 pole 16 KA, 125 Amp - 04 Nos (outgoing)
(k) MCB DP 16 KA, 40 Amp - 01 Nos (outgoing) | 1 | Each Job | - | - |
| 3 | Supply, installation, testing and commissioning in replacement of LT panel board as pere IS 8632, made out of 3.15mm thick CRCA sheet, outdoor cubical type (double door) totally enclosed weather, dust and vermin proof with front and rear opening of 415 volots, 3 phase, 4 wire 50 Hz including internal wiring with copper conductor and two coats of synthetic enamel paint over a coat of red oxide primer including connecting all incoming and outgoing cable feeders with necessary cable glants, thimbles etc. The panel should have 4 No of angle iron base frame made of 40x40x6mm (60 cm long legs) fixed in ground including 30x30x30cm PCC 1:2:4 type B-1 using 20mm graded stone aggregates, finishing with plaster 15mm thick in cement mortar 1:4 and comprising of the following switchgear, accessories, complete all as specified and directed :-
(a) 04 strips of Aluminium bus bars with insulation colour sleeves of capacity 600 Amp fixed on PVC heat shrinkable insulator heavy duty.
(b) Volt meter 0-500 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch - 01 No
(c) Amp meter 0-300 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch with suitable size CTs - 01 No
(d) Indicator lamp LED type on all phases (R. Y. B.) -03 Nos
(e) MCCB 3 phase, 415 volts, 4 pole 25 KA, 315 Amp -01 No (incoming)
(f) MCCB 3 phase, 415 volts, 4 pole 25 KA, 100 Amp -05 Nos (outgoing) | 1 | Each Job | - | - |
| 4 | Supply, installation, testing and commissioning in replacement of LT panel board as pere IS 8632, made out of 3.15mm thick CRCA sheet , outdoor cubical type (double door) totally enclosed weather, dust and vermin proof with front and rear opening of 415 volots, 3 phase, 4 wire 50 Hz including internal wiring with copper conductor and two coats of synthetic enamel paint over a coat of red oxide primer including connecting all incoming and outgoing cable feeders with necessary cable glants, thimbles etc. The panel should have 4 No of angle iron base frame made of 40x40x6mm (60 cm long legs) fixed in ground including 30x30x30cm PCC 1:2:4 type B-1 using 20mm graded stone aggregates, finishing with plaster 15mm thick in cement mortar 1:4 and comprising of the following switchgear, accessories, complete all as specified and directed :-
(a) 04 strips of Aluminium bus bars with insulation colour sleeves of capacity 600 Amp fixed on PVC heat shrinkable insulator heavy duty.
(b) Volt meter 0-500 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch - 01 No
(c) Amp meter 0-300 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch with suitable size CTs - 01 No
(d) Indicator lamp LED type on all phases (R. Y. B.) -03 Nos
(e) MCCB 3 phase 415 Volts 4 pole 36 KA 400 Amp - 01 No (incoming)
(f) MCCB 3 phase, 415 volts, 4 pole 25 KA, 100 Amp -06 Nos (outgoing)
(g) MCB DP 16 KA, 63 Amp -01 Nos (outgoing) | 1 | Each Job | - | - |
| 5 | Supply, installation, testing and commissioning in replacement of LT panel board as pere IS 8632, made out of 3.15mm thick CRCA sheet , outdoor cubical type (double door) totally enclosed weather, dust and vermin proof with front and rear opening of 415 volots, 3 phase, 4 wire 50 Hz including internal wiring with copper conductor and two coats of synthetic enamel paint over a coat of red oxide primer including connecting all incoming and outgoing cable feeders with necessary cable glants, thimbles etc. The panel should have 4 No of angle iron base frame made of 40x40x6mm (60 cm long legs) fixed in ground including 30x30x30cm PCC 1:2:4 type B-1 using 20mm graded stone aggregates, finishing with plaster 15mm thick in cement mortar 1:4 and comprising of the following switchgear, accessories, complete all as specified and directed :-
(a) 04 strips of Aluminium bus bars with insulation colour sleeves of capacity 1000 Amp fixed on PVC heat shrinkable insulator heavy duty.
(b) Volt meter 0-500 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch - 01 No
(c) Amp meter 0-300 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch with suitable size CTs - 01 No
(d) Indicator lamp LED type on all phases (R. Y. B.) -03 Nos
(e) MCCB 3 phase 415 Volts 4 pole 36 KA 630 Amp - 01 No (incoming)
(f) MCCB 3 phase, 415 volts, 4 pole 25 KA, 200 Amp -05 Nos (outgoing) | 1 | Each Job | - | - |
| 6 | Supply, installation, testing and commissioning in replacemnt of LT panel board as pere IS 8632, made out of 3.15mm thick CRCA sheet , outdoor cubical type (double door) totally enclosed weather, dust and vermin proof with front and rear opening of 415 volots, 3 phase, 4 wire 50 Hz including internal wiring with copper conductor and two coats of synthetic enamel paint over a coat of red oxide primer including connecting all incoming and outgoing cable feeders with necessary cable glants, thimbles etc. The panel should have 4 No of angle iron base frame made of 40x40x6mm (60 cm long legs) fixed in ground including 30x30x30cm PCC 1:2:4 type B-1 using 20mm graded stone aggregates, finishing with plaster 15mm thick in cement mortar 1:4 and comprising of the following switchgear, accessories, complete all as specified and directed :-
(a) 04 strips of Aluminium bus bars with insulation colour sleeves of capacity 600 Amp fixed on PVC heat shrinkable insulator heavy duty.
(b) Volt meter 0-500 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch - 01 No
(c) Amp meter 0-300 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch with suitable size CTs - 01 No
(d) Indicator lamp LED type on all phases (R. Y. B.) -03 Nos
(e) MCCB 3 phase 415 Volts 4 pole 36 KA 400 Amp - 01 No (incoming)
(f) MCCB 3 phase, 415 volts, 4 pole 25 KA, 100 Amp -03 Nos (outgoing)
(g) MCCB 3 phase 415 volts 4 pole 25 KA 160 Amp - 01 Nos (outgoing)
(h) MCCB 3 phase 415 volts 4 pole 25 KA 200 Amp - 01 Nos (outgoing) | 1 | Each Job | - | - |
| 7 | Supply, installation, testing and commissioning in replacement of LT panel board as pere IS 8632, made out of 3.15mm thick CRCA sheet , outdoor cubical type (double door) totally enclosed weather, dust and vermin proof with front and rear opening of 415 volots, 3 phase, 4 wire 50 Hz including internal wiring with copper conductor and two coats of synthetic enamel paint over a coat of red oxide primer including connecting all incoming and outgoing cable feeders with necessary cable glants, thimbles etc. The panel should have 4 No of angle iron base frame made of 40x40x6mm (60 cm long legs) fixed in ground including 30x30x30cm PCC 1:2:4 type B-1 using 20mm graded stone aggregates, finishing with cement mortar and comprising of the following switchgear, accessories, complete all as specified and directed :-
(a) 04 strips of Aluminium bus bars with insulation colour sleeves of capacity 600 Amp fixed on PVC heat shrinkable insulator heavy duty.
(b) Volt meter 0-500 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch - 01 No
(c) Amp meter 0-300 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch with suitable size CTs - 01 No
(d) Indicator lamp LED type on all phases (R. Y. B.) -03 Nos
(e) MCCB 3 phase 415 Volts 4 pole 36 KA 400 Amp - 01 No (incoming)
(f) MCCB 3 phase, 415 volts, 4 pole 25 KA, 100 Amp -02 Nos (outgoing)
(g) MCCB 3 phase 415 volts 4 pole 25 KA 160 Amp - 01 Nos (outgoing)
(h) MCCB 3 phase 415 volts 4 pole 25 KA 200 Amp - 02 Nos (outgoing) | 1 | Each Job | - | - |
| 8 | Supply, installation, testing and commissioning in replacement of LT panel board as pere IS 8632, made out of 3.15mm thick CRCA sheet , outdoor cubical type (double door) totally enclosed weather, dust and vermin proof with front and rear opening of 415 volots, 3 phase, 4 wire 50 Hz including internal wiring with copper conductor and two coats of synthetic enamel paint over a coat of red oxide primer including connecting all incoming and outgoing cable feeders with necessary cable glants, thimbles etc. The panel should have 4 No of angle iron base frame made of 40x40x6mm (60 cm long legs) fixed in ground including 30x30x30cm PCC 1:2:4 type B-1 using 20mm graded stone aggregates, finishing with plaster 15mm thick in cement mortar 1:4 and comprising of the following switchgear, accessories, complete all as specified and directed :-
(a) 04 strips of Aluminium bus bars with insulation colour sleeves of capacity 400 Amp fixed on PVC heat shrinkable insulator heavy duty.
(b) Volt meter 0-500 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch - 01 No
(c) Amp meter 0-300 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch with suitable size CTs - 01 No
(d) Indicator lamp LED type on all phases (R. Y. B.) -03 Nos
(e) MCCB 3 phase 415 Volts 4 pole 25 KA 250 Amp - 01 No (incoming)
(f) MCCB 3 phase, 415 volts, 4 pole 16 KA, 63 Amp -07 Nos (outgoing) | 1 | Each Job | - | - |
| 9 | Supply, installation, testing and commissioning in replacemnt of LT panel board as pere IS 8632, made out of 3.15mm thick CRCA sheet , outdoor cubical type (double door) totally enclosed weather, dust and vermin proof with front and rear opening of 415 volots, 3 phase, 4 wire 50 Hz including internal wiring with copper conductor and two coats of synthetic enamel paint over a coat of red oxide primer including connecting all incoming and outgoing cable feeders with necessary cable glants, thimbles etc. The panel should have 4 No of angle iron base frame made of 40x40x6mm (60 cm long legs) fixed in ground including 30x30x30cm PCC 1:2:4 type B-1 using 20mm graded stone aggregates, finishing with plaster 15mm thick in cement mortar 1:4 and comprising of the following switchgear, accessories, complete all as specified and directed :-
(a) 04 strips of Aluminium bus bars with insulation colour sleeves of capacity 600 Amp fixed on PVC heat shrinkable insulator heavy duty.
(b) Volt meter 0-500 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch - 01 No
(c) Amp meter 0-300 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch with suitable size CTs - 01 No
(d) Indicator lamp LED type on all phases (R. Y. B.) -03 Nos
(e) MCCB 3 phase 415 Volts 4 pole 36 KA 315 Amp - 01 No (incoming)
(f) MCCB 3 phase, 415 volts, 4 pole 25 KA, 200 Amp -01 Nos (outgoing)
(g) MCCB 3 phase 415 volts 4 pole 25 KA 160 Amp - 01 Nos (outgoing)
(h) MCCB 3 phase 415 volts 4 pole 25 KA 100 Amp - 02 Nos (outgoing) | 1 | Each Job | - | - |
| 10 | Supply, install, testing and commissioning in replacement of LT panel board as pere IS 8632, made out of 3.15mm thick CRCA sheet , outdoor cubical type (double door) totally enclosed weather, dust and vermin proof with front and rear opening of 415 volots, 3 phase, 4 wire 50 Hz including internal wiring with copper conductor and two coats of synthetic enamel paint over a coat of red oxide primer including connecting all incoming and outgoing cable feeders with necessary cable glants, thimbles etc. The panel should have 4 No of angle iron base frame made of 40x40x6mm (60 cm long legs) fixed in ground including 30x30x30cm PCC 1:2:4 type B-1 using 20mm graded stone aggregates, finishing with plaster 15mm thick in cement mortar 1:4 and comprising of the following switchgear, accessories, complete all as specified and directed :-
(a) 04 strips of Aluminium bus bars with insulation colour sleeves of capacity 1000 Amp fixed on PVC heat shrinkable insulator heavy duty.
(b) Volt meter 0-500 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch - 01 No
(c) Amp meter 0-300 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch with suitable size CTs - 01 No
(d) Indicator lamp LED type on all phases (R. Y. B.) -03 Nos
(e) MCCB 3 phase 415 Volts 4 pole 36 KA 630 Amp - 01 No (incoming)
(f) MCCB 3 phase, 415 volts, 4 pole 25 KA, 100 Amp -05 Nos (outgoing)
(f) MCCB 3 phase, 415 volts, 4 pole 25 KA, 125Amp -04 Nos (outgoing) | 2 | Each Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
TD.pdf
Tender Documents • 0.82 MB
BOQ_896587.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .