Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹38.6 LAccepted-AOC | 1 | Accepted-AOC Being Lowest Bidder | |
| 2 | 2₹43.4 L+₹4.8 L (12.4%)Rejected-Finance | 2 | Rejected-Finance Not Being Lowest Bidder | |
| 3 | 3₹43.7 L+₹5.1 L (13.1%)Rejected-Finance D NO 18 13 4 3RD FLOOR HILL CREST APARTMENT SEETHAMADHARA NORTH EXTENSION VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | 3 | Rejected-Finance Not Being Lowest Bidder | |
| 4 | 4₹47.2 L+₹8.6 L (22.2%)Rejected-Finance | 4 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
15 May 2020, 6:00 pmClosed
Shri VK Tiwari, IDSE, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
Special Repairs to Hospital Laundry Building No. P - 113 at INHS Kalyani, Visakhapatnam
2020_MES_339359_1
82025 / E8
Open Tender
Civil Works
Item Rate
180 days
Visakhapatnam
Class D
Category a i
9 documents required · 9 mandatory
₹500
Garrison Engineer Naval Base
₹1 L
Yes
4 Jun 2020
17 Apr 2020
22 May 2020
17 Apr 2020
15 May 2020
1 May 2020
17 Apr 2020 - 24 Apr 2020
Amount
Demolition of Unreinforced Cement Concrete in ground floors and Pavings not exceeding 15cm thick [below or above ground level] and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for 40 mm average thick, PCC 1:2:4, Type B-1, using 20mm graded aggregate as in Padding over roof slabs etc. and finishing the top surface rough complete all as specified and as directed.
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 10mm thick in cement mortar 1:3 on concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth to receive the water proofing membrane, priming the surface with a coat of cold applied bituminous primer @ 0.50 KG per Sq.m, applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m, laying Polymeric water proofing membrane of weight not less than 3.00 Kg per Sq.m reinforced with polyester non-woven fabric of weight not less than 150 Grams per Sq.m, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion including applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m and finished with a coat of bituminous aluminium paint @ 100 grams per Sq.m on top for water proofing treatment complete complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
Dismantling of Floor, Hearth or Wall Tiling of any description including Cement Mortar bedding [but not backing] and removing serviceable tiles to the stores and removing rubbish / debris to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for 25 mm thick, PCC 1:2:4, Type B-0, using 10mm graded aggregate as in Sub base for flooring complete all as specified and as directed.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.18 Sq.m and not exceeding 0.38 Sq.m, 8 to 9 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for machine cut Kota stone slab flooring using 20 to 25mm thick slabs, laid and jointed with grey cement slurry mixed with a admixture of pigment to match shade of slab including rubbing and polishing to smooth mirror finish all to required sizes, the size and design / pattern of slabs shall be as directed, including diagonals, inlays, borders, margins in two or more shades of slabs including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed.
M & L for machine cut Kota stone slab as in riser of steps, skirting, dado etc. using 20 to 25mm thick slabs laid and jointed with grey cement slurry mixed with a admixture of pigment to match shade of slab including rubbing and polishing to smooth mirror finish all to required sizes, the size and design / pattern of slabs shall be as directed, including borders, margins in two or more shades of slabs over backing coat of 10mm thick in cement mortar 1:3 complete all as specified and as directed.
M & L for Joint Free Glazed Ceramic Tiles, Edge Cut, Concept Type, Coloured, Premium Quality, of size 450 mm X 300 mm, 7 to 8 mm thick as in Vertical Surfaces such as Skirting, Dado etc set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. The colour / shade / design of tiles shall be as approved by GE.
M & L for Glazed Polish finished coloured Chequered Cement Concrete Tiles of thickness 23 to 25mm, made with M-25 Grade Precast Cement Concrete, Hydraulically pressed of size not less than 300 X 300 mm, of approved shape, colour and pattern, set, jointed and pointed in neat cement slurry to match including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 complete all as specified and as directed.
M & L for preparing newly plastered wall / ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint on walls / ceilings complete all as specified and as directed.
M & L for preparing newly plastered wall / Ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper over a coat of alkali resistant primer on walls complete all as specified and as directed.
M & L for Complete removal of existing treatment of any description on wall / Ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper over one of alkali resistant primer on wall / Ceiling surfaces complete all as specified and as directed.
M & L for Complete removal of existing treatment of any description on walls and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint on walls complete all as specified and as directed.
M & L for two coats of synthetic enamel paint over one coat of pink primer to newly untreated wooden surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces etc including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:4, including mixing water proofing compound as per manufacturers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
M & L for rendering to brick / concrete surfaces, 10 mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering 5 mm thick in Cement Mortar 1:3 on fair faces of concrete surface of ceiling surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 25mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 duly modifying the mortar with and including suitable bonding agent of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 5% of weight of cement for soffits of Slabs, Beams, Columns, Fins, Parapets Facias & Chajjas etc., finishing surface rough and finally rendering 10 mm thick in Cement Mortar 1:4 and finishing the top surface even and smooth without using extra cement conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of MD land complete all as specified and as directed.
M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 30mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 duly modifying the mortar with and including suitable bonding agent of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 5% of weight of cement for soffits of Slabs, Beams, Columns, Fins, Parapets Facias & Chajjas etc., finishing surface rough and finally rendering 10 mm thick in Cement Mortar 1:4 and finishing the top surface even and smooth without using extra cement conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of MD land complete all as specified and as directed.
Taking down Chowkats or frame with shutters [without taking off shutter from the frame] exceeding 1.5 Sq.m but not exceeding 4.00 Sq.m each and removing to store complete all as specified and as directed.
Taking down Chowkats or frame with shutters [without taking off shutter from the frame] not exceeding 1.5 Sq.m each and removing to store complete all as specified and as directed.
S & F Second Class Hard Wood, plain, solid, straight Chowkats and Frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed.
S & F Factory made, 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
M & L for Powder Coated Aluminium Sections [Minimum 50 Micron thick] of approved colour as in Door, Window, Ventilator Frames, Partitions with one or more rebates and Door, Window, Ventilator Shutters, Sliding or Openable Type, with or without Sash Bar, Aluminium section weighing 0.55 KG / RM including necessary Joining Cleats, Glazing Clips, Neoprene Rubber Packing, Powder Coated Aluminium Snap Beading, Screws, Powder Coated Aluminium Fittings such as Locking Arrangement [1 No], Suitable Handle [1 No], Stainless Steel Friction Hinges [1 No] per Window Shutter and 150mm Dia Handles on both sides, Tower bolts, 200 mm Long [2 Nos], Double Action Floor Spring Hydraulically Regulated made of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty etc. per Door Shutter complete all as specified and as directed. Note: [a] The size of aluminium sections shall be all as specified in relevant IS code and MES Schedule Part - I. [b] Supply only panel inserts of Glass / Particleboard / Gauze / Grills will be measured and paid separately. [c] Unit rate quoted shall be deemed to include for cost of rubber beading, glazing clips, neoprene packing, fittings such as Handles, Butt hinges, Tower Bolts, Stainless Steel Friction Hinges and fixing only of panel inserts of Glass / Particleboard / Gauze / Grills etc.
Supply only Powder Coated Aluminium Deco Grill of Model / Design No. DG 104 including Powder Coated Aluminium Channel / F Channel of size 20 X 12 X 1mm for fixing Deco Grill complete all as specified and as directed.
Supply only 5mm thick Tinted Glass ordinary quality in squares not exceeding 0.5 Sq.m in each pane complete all as specified and as directed.
Supply only Stainless steel wire cloth / mesh with average aperture not exceeding 1.40 mm and dia of wire 0.36 mm complete all as specified and as directed.
S & F Solid PVC door frame of size 100mmX45mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening complete all as specified and as directed.
S & F Factory made solid panel PVC door shutter 30 mm thick [Style] consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC "C" Channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement fixing in frame at site as per specification complete all as specified and as directed.
S & F Aluminium alloy anodised Sliding Door Bolt with hasp and staple [Bolt Type] of size 300 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S & F Aluminium anodised barrel Tower Bolt of size 200 mm size of extruded section complete all as specified and as directed.
S & F 125 mm size, Butt hinges, Stainless Steel, Medium weight, bright polished including fixtures complete all as specified and as directed.
S & F Aluminium anodised Handle, of extruded section Fabricated Type of size 150mm long complete all as specified and as directed.
S & F Floor Door Stopper of size 150 mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and as directed.
S & F PVC Solid Ventilator frame size 55 X 47mm with wall thickness of 5mm made out of extruded 5mm PVC sheet, mitre cut at two comers and jointed with 2 Nos of 150mm long brackets of 15 x 15mm MS square tube, the two vatted profiles are to be reinforced with 19 x 19mm MS square tube, 50% of bottom portion is fixed with 4mm thick pin headed glass and balance 50% of top portion is fixed with 4mm thick pin headed glass louvers and covered with 0.36mm dia stainless steel wire mesh at top portion including necessary PVC beading with screws and 3 Nos 12mm dia MS guard, bars fixed in ventilator frame including two coats of synthetic enamel paint over a coat of red oxide primer to MS guard bars etc. complete all as specified and as directed.
S & F in repairs Collapsible Steel Gates, Top Hung, consisting of Channel Pickets, Pivoted Flat Bars, Top and Bottom Runners, Brass Handles etc. as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and as directed.
M & L for two coats of synthetic enamel paint over one coat of pink primer to newly untreated wooden surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
Demolition of Brick / Stone Masonry built in Cement Mortar including all quoins arches pillars etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
Demolition of Reinforced Cement Concrete in ground floors and Pavings not exceeding 15cm thick [below or above ground level] and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for PCC 1:4:8, Type D-2, using 40mm graded stone aggregate as in Foundation, Fillings, Mass concrete, Footings etc complete all as specified and as directed.
M & L for walling of random rubble masonry, uncoursed, well bonded, bedded and solidly hearted, built in Cement Mortar 1:6 complete all as specified and directed.
M & L for rendering to stone masonry surfaces or surfaces other than fair faces of brick surfaces or on one side of lathing, 15mm thick in Cement Mortar 1:4, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Parapets, Facias & Fins etc. complete all as specified and as directed.
M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span etc. complete all as specified and as directed.
M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Chajjas and the like complete all as specified and as directed.
M & L for RCC M–30 Design Mix, using 20mm graded stone aggregate as in foundations including Pile Caps, Rafts, Footings, Foundation Beams, Plinth Beams, Bases for Columns etc. complete all as specified and as directed.
Use and removal of steel formwork to sides of concrete foundations, pile caps, footings, bases of columns, raft and raft beams, sides and soffits [if any] of foundation and plinth beams and similar work, vertical or to batter for rough finished surfaces complete all as specified and as directed.
Use and removal of steel formwork to Fins, Louvers, Fascia and similar works etc., vertical or to batter for fair finished surfaces complete all as specified and as directed. sides of concrete
Use and removal of steel formwork to sides and soffits of floor or roof beams, beam launchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc, splays between floors and beams and similar works for fair finished surfaces of concrete complete all as specified and as directed.
Use and removal of steel formwork to Chullah hoods, Chajjas, troughs and similar items including edges and similar works for fair finished surfaces of concrete complete all as specified and as directed.
M & L for providing Precast RCC 1:2:4, Type B-1 using 20mm graded stone aggregate as in landings, cover slabs [for manholes etc], Chullah hoods, Chajjas, water troughs, mangers, Shelves and similar articles with plain faces set in cement mortar 1:6 complete all as specified and as directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 5mm to 10mm dia bars as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
M & L for PCC 1:5:10, Type E-2, using 40mm graded stone aggregate as in Sunken Floors etc complete all as specified and as directed.
M & L for brick work in half brick thick walls using Fly Ash bricks straight or curved on plan to any radius built in Cement Mortar 1:4 including 2 Nos of 6mm dia bars at every fourth course of brick work complete all as specified and as directed.
S & F Rotational Moulded Polythene [HDPE] Water Tanks, Triple Layered, ISI Marked, Cylindrical & Vertical Type 1000 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete including taking down old tanks and removing to store complete all as specified and as directed.
Taking down or up steel tubing and connections for 15 mm bore of pipe complete all as specified and as directed.
Taking down or up steel tubing and connections for 20 mm bore of pipe complete all as specified and as directed.
Taking down or up steel tubing and connections for 25 or 32 mm bore of pipe complete all as specified and as directed.
S & F GI water tubing of 15 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F GI water tubing of 20 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F GI water tubing of 25 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 25 mm bore with iron wheel head, screwed both ends for iron pipe, confirming to IS, ISI Marked complete all specified and as directed.
S & F in repairs Vitreous China Ware Wash Hand Basin, White, Flat Back of size 550 mm X 400 mm including 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible Waste Pipe, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. complete all as specified and as directed.
S & F Vitreous China Wash Down Water Closet [Pedestal pattern], White, including 10 Litres capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. including brackets and connections to pipe and flush pipe including plastic water closet seat back closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and 'P' or 'S' trap complete all as specified and as directed.
S & F Vitreous China Urinal, Half Stall Type, Flat Back or Corner Wall Type, White, complete including providing and fixing plugs, bedding urinal against wall in cement mortar [1:2], securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, including 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, 32mm bore PVC flexible waste pipe, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc., grating and union for discharge pipe, CP screws etc. complete all as specified and as directed.
S & F in repairs Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with or with out lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as per Jaquar Catalogue No. CON-011KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
S & F in repairs Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type, Short Body with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as per Jaquar Catalogue No. CON-047KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
S & F in repairs Stop Valves, 15 mm dia, cast copper alloy with capstan head, Chromium Plated, Fancy Type, screwed down high pressure with crutch or butterfly handle with long shank and cup [concealed type] for iron pipe etc complete all as per Jaquar Catalogue No. CON-083KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
S & F in repairs Angle Cock, 15 mm dia, cast copper alloy with capstan head, Chromium Plated, screwed down high pressure with crutch or butterfly handle for iron pipe etc. complete all as per Jaquar Catalogue No. CON-053KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
S & F in repairs Brass Chromium Plated Tubular Towel Rail, 20mm dia, D Type, 600 mm long between flanges complete all as specified and as directed.
S & F in repairs Brass Chromium Plated Shower Rose of size 125mm with or with out swivel joints fixing to steel pipes complete all as specified and as directed.
S & F 110mm bore PVC [SWR] Multi Floor Trap with grating including jointing with solvent cement complete all as specified and as directed.
S & F in repairs 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed.
S & F in repairs 75mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes complete all as specified and as directed.
S & F 75 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed.
S & F 75 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
S & F 75mm bore PVC [SWR] Multi Floor Trap with grating including jointing with solvent cement complete all as specified and as directed.
S & F in repairs Health Faucet with 1 m long flexible tube, wall hook, non return valve complete as per Jaquar Catalogue No. ALD-577 or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness, conducting Phenolphthalein test and cleaning the surface and ensuring the surface is clean and free from loose particles including disposal and depositing the demolished material out of MD land complete all as specified and as directed. Note: During the Phenolphthalein test if it is found that there is no change in the colour, the cutting / chipping of the concrete shall be carried out further down until reaching the good or uncontaminated concrete.
M & L for preparation of the surface by wire brushing and thoroughly cleaning the surface with dry cloth to remove all the dust and applying One Coat of Alkaline Rust Converter of M/s. Fosroc Chemicals India [P] Ltd. or M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions by brush to all accessible parts of exposed rusted metal surface and allowed to react with the chemical for 16-24 hours and the surface shall be again wire brushed to remove any leftover loose particles and finally the surface shall be thoroughly cleaned with clean water complete all as specified and as directed.
M & L for applying One Coat of Corrosion Inhibitor of M/s. Fosroc Chemicals India [P] Ltd. or M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions on entire repair area complete all as specified and as directed. Note: The Corrosion Inhibitor shall be applied after provision of additional reinforcement etc. if any.
M & L for applying Two Coats of Epoxy Phenolic Based / Epoxy Based Anti-Corrosive Protective Coating of M/s. Fosroc Chemicals India [P] Ltd. or M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions by preparing the chemical using a slow speed heavy duty drilling machine fitted with mixing paddle and the prepared solution shall be applied immediately to the cleaned reinforcement and allowed to dry complete all as specified and as directed.
M & L for applying One Coat / providing impregnation into prepared concrete by using Low Viscosity Resin M/s. Fosroc Chemicals India [P] Ltd. or M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions over the entire repair surface including the portion where new screed is to be laid as per manufacturer’s recommendations and at the rate of not less than 0.25 KG / Sq.m by brush and the resin shall be worked in to all the cracks by repeated application by brush to seal all the cracks by capillary action complete all as specified and as directed.
M & L for applying One Coat of Epoxy Bond Coat [Twp Pack] M/s. Fosroc Chemicals India [P] Ltd. or M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions to ensure perfect bonding between old concrete and new treatment including preparation of the surface as per manufacturer’s instructions complete all as specified and as directed.
M & L for applying Polymer Modified Mortar made using Shrinkage Compensated Polymer Modified Fibre Reinforced Cementitious Repair Mortar such as Renderoc SP 40 of M/s. Fosroc Chemicals India [P] Ltd. or equivalent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions to form average 20 mm thick even surface complete all as specified and as directed.
M & L for Micro Concreting for jacketing of Columns using Single component, shrinkage compensated, high strength, high flow cementitious micro-concrete having compressive strength minimum of M40 at 28 days such as Sikkarep Microcrete-4 of M/s. Sika India Pvt. Ltd. or equivalent in M/s. Fosroc Chemicals India [P] Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions blended with washed saturated surface dry [SSD], graded, low absorption, high density, aggregates of size 3mm to 10mm at 50% by weight of micro concrete [if thickness is 100mm or more] and water as per data sheet and pouring into the shuttering if required using birds beak type form work using suitable arrangement or if required using pumping device for uniform flow of Micro concrete complete all as specified and as directed. Note: The sides shuttering shall be removed preferably after 3 days and the bottom shuttering shall be removed preferably after 7 days ensuring proper bond between the micro concrete and existing concrete substrate.
M & L for providing additional reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D by checking the diameter of the existing bars, cutting the necessary main reinforcement to the required length with proper development length, tying / binding / welding with the existing shear connectors / reinforcement so that the additional reinforcement acts monolithically with the existing reinforcement and core concrete complete all as specified and as directed. Note: The shear reinforcement shall also be provided as specified here-in-above in the form of 2 "U" shaped bars if existing shear reinforcement is found deteriorated / diameter of the bars is reduced. Diameter of the new bar shall be equal to the existing bars. Additional reinforcement shall be provided only in case the diameter of the existing bars is found less than 30% of the original diameter.
M & L for providing grouting with Injection Grout M/s. Fosroc Chemicals India [P] Ltd. or M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions for cracks caused by structural distress such as shear cracks, flexural cracks, tensile cracks etc. by injecting low viscosity epoxy resin complete all as specified and as directed.
M & L for drilling and fixing PVC Nozzles for injecting cementitious polymeric grout to fill the honeycombing noticed after removal of shuttering inside the beams, columns, slabs etc. including removal of loose concrete material complete all as specified and as directed.
M & L for dismantling existing waterproofing system including PCC Padding, Cement Concrete tiles of any thickness, overlay etc. form the top of the roof slabs to expose the substrate/RCC slab beneath, cleaning the surface by mechanical means to make the surface free from dirt, foreign particles, laitance followed by grinding all protrusions to make surface modulated and finally the surface shall be thoroughly cleaned with clean water and disposal and depositing the demolished material out of MD land complete all as specified and as directed.
M & L for carrying out water test to identify direct dripping leakages from slab and carrying out Injection Grouting using cement grout admixed with non-shrink admixture such as Cebex 100 of M/s. Fosroc Chemicals India [P] Ltd. or equivalent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. at the location of leakage, cracks and in a grid pattern as per manufacturer's instructions complete all as specified and as directed.
M & L for applying One Coat of Sealer Coat over the bare slab, after proper surface cleaning and completion of injection grouting, using Acrylic polymer such as STP Shalicrete E of M/s. STP Ltd. or equivalent in M/s. Fosroc Chemicals India [P] Ltd. or M/s. Sika India Pvt. Ltd. or or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. duly mixed with cement in the ratio of 1:3 per KG of cement and applied by brush as per manufacturer's instructions complete all as specified and as directed.
Note for Serial Item No. 86 to 99: Rate quoted is deemed to be including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of MD land complete all as specified and as directed. Nothing shall be paid extra on this account.
S & F in repairs UPVC Pipe of 110 mm bore, of pressure rating 4 KGf / Sq.cm including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, sockets etc and fixed to walls, ceiling, and laid on floors including testing complete all as specified and as directed.
Taking down carefully copper / aluminium point wiring [light, fan, socket or power] complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and making good the disturbed surfaces all as per existing complete all as specified and as directed.
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and 3 mm thick Hylam Sheet top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified and as directed.
All as per Serial Item No. 102 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified.
All as per Serial Item No. 102 above but one 3 Pin Switch Socket Outlet 15 Amps on independent board, with 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
S & F Switch Piano, Flush Button, Single Pole, One Way, 5 Amps, 230 Volts complete all as specified and as directed.
S & F Ceiling Rose, Surface Bakelite, 65 X 50 mm, Three Terminals, 230 Volts complete all as specified and as directed.
S & F Switch Socket Outlet, 3 & 2 Pin, Multipurpose, 5 Amps, 230 Volts, Flush Type complete all as specified and as directed.
S & F Switch Socket Outlet, Multipurpose, 3 pin, 15 Amps and 3 pin, 5 Amps, Flush Type, 230 Volts controlled by One Switch complete all as specified and as directed.
M & L for Sub main wiring with 4 runs of single core 10 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 32 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including 2 runs of 10 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 6 runs of 10 Sq.mm & one run of 32 mm dia PVC Conduit will be measured as one unit
S & F in repairs MCCB, FP, 100 Amps, 16 KA, 415 Volts, 50 Hz, suitable for fixing on N3 Frame complete all as specified and as directed.
S & F in repairs MCCB, FP, 63 Amps, 16 KA, 415 Volts, 50 Hz, suitable for fixing on N3 Frame complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep in Soft / Loose soil for laying Cables etc. complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
Removal of excavated material [Soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M & L for Dry River Sand cushioning over and around the cable for cable protection in trenches, levelled and punned down complete all as specified and as directed. Note: The punned down thickness shall be measured for payment.
Supply and lay Bricks, Common Burnt, Clay Building Bricks, Sub–Class "B", Designation 75 in trenches for cable protection complete all as specified and as directed.
Supplying and laying GI pipe, 40mm dia, Light grade for cable protection at road crossing etc. or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed.
Supplying and laying GI pipe, 80mm dia, Light grade for cable protection at road crossing etc. or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed.
Cutting Bituminous Road / Hardstanding etc. as required for Jointing / Laying Cables and Pipeline of width not exceeding 300mm and depth not exceeding 600mm and refilling after laying and making good with PCC 1:2:4, Type B1 using 20mm graded stone aggregate, 100mm thick complete all as specified and as directed.
M & L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machinery including GI pipe, 80mm bore, Light grade for drawing cable complete all specified and as directed.
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 240 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 35 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 25 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
S & F in repairs Earth continuity Conductor or main earthing lead made of GI Strip of size 32 X 6mm, fixed to wall on batten or recess or chases or buried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
Pavan Commercial Company
M/s Sudersana Traders
SN POWER TECH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .