| 1 | L1₹27.4 LAccepted-AOC 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹29.0 L+₹5,833 (0.20%)Rejected-Finance 27 19 F F D BLOCK CHATTARPUR EXTN SOUTH WEST DELHI DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹29.9 L+₹92,813 (3.21%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹31.3 L+₹2.4 L (8.23%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹34.1 L+₹5.2 L (18.1%)Rejected-Finance 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
24 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY AMBALA CANTT
GE UTILITY AMBALA CANTT GE UTILITY AMBALA CANTT
REPAIR MAINT OF LT ELECTRIC DISTRIBUTION SYSTEM IN OFFRs JCOs ORs MD ACCN AT SECTOR B UNDER GE UTILITY AMBALA CANTT
2024_MES_647751_1
CA NO GE U AMB T 27 OF 2024-25
Open Tender
Civil Works
Works
240 days
GE UTILITY AMBALA CANTT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹88,000
18 May 2024
23 Mar 2024
26 Apr 2024
23 Mar 2024
24 Apr 2024
10 Apr 2024
23 Mar 2024 - 30 Mar 2024
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, shafts, man holes,for under ground cable / erection of poles, stays, locating fault of LT cable and stay assembly etc not exceeding 10 square metre on plan and getting out in any type of soil including dressing/trimming of sides and leveling, grading and ramming of bottom of excavation complete all as specified & directed.
Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, complete all as specified & directed.
All as per item No 1.00 here in before but depth exceeding 1.5 metre and not exceeding 3.0 metre complete all as specified & directed
Returning, filling in soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each layer complete all as specified & directed.
Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified & directed.
Material and labour for sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after laying the cable (punned down to 18 cms depth after laying and stretching of cable) complete all as specified & directed
Supply and lay bricks, common burnt clay, sub class "B', old size, laid in vertical direction to cable as cable protection complete all as specified & directed.
All as per Item Ser No 7.00 here in before but except bricks, complete all as specified & directed Note:- Old bricks retrieved from Item Ser No 13.00 here in after shall be re- used.
Material and labour for PCC 1:4:8 type D-2 using 40mm graded aggregate, mechanically crushed stone for mass filling in pole pit and foundation etc. complete all as specified & directed
Material and labour cement concrete (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in coping of pole and strut, stay around the pole etc complete all as specified & directed.
Material and labour of PCC 1:2:4 Type B-1 using 20 mm graded aggregate for coping of poles including necessary form work and finishing the exposed surface even and smooth with out using extra cement complete all as specified & directed.
Disconnecting & taking out defective underground cable from trenches, pole, pipe, floor, wall etc and locate the fault, rectify the defect and relaying the XLPE cable underground PVC insulated and overall sheathed aluminum conductor heavy duty 1100 volts including connecting and testing for any size complete all as specified & directed (Excavation/earth work & sand cushioning, bricks and joint shall be measured & paid for separately).
Disconnecting & taking out defective underground cable any size and any type from trenches, pole, pipe, floor, watt etc complete all as specified & directed
Supply and laying, connecting, testing in replacement of XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 sqmm 4.0 core laid in trenches/ on pole/road crossing or passing through existing/new pipe under road crossing clamping on wall incl aluminium thimbles/lugs etc complate all as specified & directed . Note: (i) Earth work, sand , bricks removing , returning filling will be paid seperately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates (iii) All equiments, machinery or tool if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
All as per item ser No 14 here in before but for 3.5 core 25 Sqmm complete all as specified & directed
All as per item ser No 14 here in before but for 3.5 core 35 Sqmm complete all as specified & directed
All as per item ser No 14 here in before but for 3.5 core 50 Sqmm complete all as specified & directed
All as per item ser No 14 here in before but for 3.5 core 70 Sqmm complete all as specified & directed
All as per item ser No 14 here in before but for 3.5 core 95 Sqmm complete all as specified & directed
All as per item ser No 14 here in before but for 3.5 core150 Sqmm complete all as specified & directed
All as per item ser No 14 here in before but for 3.5 core185 Sqmm complete all as specified & directed
All as per item ser No 14 here in before but for 3.5 core 240 Sqmm complete all as specified & directed
All as per item ser No 14 here in before but for 3.5 core 300 Sqmm complete all as specified & directed
Supply, Laying, connecting and testing in repacement of underground XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts cross sectional area 400 Sqmm single core grade, laid in trenches, floors, ducts passing through pipe for road crossing or in any other situation complete all as specified and directed. (Note : Excavation, earth work, brick protection, sand cushioning and GI pipe etc shall be measured & paid for separately).
Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cable flat or circular of size 10 sqmm 2 core complete all as specified and directed.
Supplying and fixing in replacement of light grade galvanised mild steel pipe 80mm bore with all fittings, laid under roads, drain, paths, fixed to poles/walls with suitable mild steel clamps , bolts , nuts and washers complete all as specified & directed Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule
All as per Item No 26 here-in-before but of size 50 mm bore complete all as specified & directed
Auger Boring under road, pavement, hard standing by trenchless technology using ultra sounding technique or manual boring and necessary machine including HDPE pipe of 50mm to 150 mm dia suitable for 0.4 mpa working pressure complete all as specified & directed
Taking down old unsv Prestressed Concrete LT pole and supply and erection of Prestressed Concrete LT pole 9.0 mtr long in true vertical position 102x172 mmm at top 102x279 mm at bottom class-10 incl providing black and white strips with synthetic enamel paint 30 cm each alternate upto 1.5 mtr above the coping of pole starting with black strip complete all as specified & directed. Note:- (i) Earth work and PCC shall be measured and paid seperately. (ii) Description as per direction of Engineer-in-Charge will be printed on each pole without any extra cost.
Taking down old unsv Steel tubular LT pole and supply and erection of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts,nuts and screws as specified type 410 SP-31 , 09 meter long, providing synthetic enamel aluminium paint over one coat of red oxide and black and white strips with synthetic enamel paint 30 cm each alternatively upto 1.5 mtr above the coping of pole starting with black strip complete all as specified & directed Note:- (i) Earth work and PCC shall be measured and paid seperately. (ii) Description as per direction of Engineer-in-Charge will be printed on each pole without any extra cost.
Supply and fixing in replacement of stay assembly complete with all accessories, such as stay plate 230x230x6 mm, stay rod 215 cm long and 16 mm dia with nuts incl GI bow turn buckle, GI stay wire, Loop type insulator etc all as per electrical plate No 1 or SSR part 1 and as directed incl taking down old unsv stay assy complete all as specified & directed. Note- The quoted rate shall include the cost of loop type insulator, stay clamps, excavation, PCC, stay wire, stay bow, turn buckle, nuts etc. complete.
Material and labour in replacement of Loop insulator Porcelain, vitreous white/brown/green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, large size with overall dimensions 90mm x 140mm, clearance of hole 25.5 mm, complete all as specified & directed
Material and lobour in replacement for shackle type porcelain vitreous white or brown insulator including GI straps washers, insulator bolts and nuts for working pressure 1100 volts, 75 mm hight, 90 mm dia, section of strip 30mmx3mm & dia of bolt 12 mm complete all as specified & directed
Taking down old unserviceable ACSR conductor material and labour for aluminium conductor steel reinforced (ACSR) conductor of size 6/1 x 2.59 (Weasel) and 6/1 x 2.11 (Squirrel) or other existing type conductor ISI marked for LT over head lines on poles including stretching, tightining of poles insulator with winding wire of suitable size with insulator/streching of ACSR conductor all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable cross-arms and material and lobour of cross arms,bracings, supports, clamps and back plates fabricated from structural steel section incl nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape of size as indicated or directed and inclusive of one primercoat, one under coat and one finishing coat of paint incl dismantling and taking down old complete all as specified and directed.
Supply and fix in replacement indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5/4.0 x 10-50 Sqmm complete all as specified & directed
Supply and fix in replacement indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 70-150 Sqmm complete all as specified & directed
Supply and fix in replacement indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 185-300 Sqmm complete all as specified & directed
Supply and fix in replacement indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 400 Sqmm complete all as specified & directed
Supply and fix in replacement straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 35-150 Sqmm complete all as specified & directed. Note: The quoted rate shall include the earth work, RF and removal of soil etc.
Supply and fix in replacement straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 185-400 Sqmm complete all as specified & directed. Note: The quoted rate shall include the earth work, RF and removal of soil etc.
Dismantling of old u/s earthing complete with galvanised earth plate electrode 600mm x 600mmx 6.00mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to 25x4 mm GI strip earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 40mm bore medium grade and connected to main switch or main control board all as shown in electrical plate No.3 of SSR Part-I & including necessary excavation and earth work. The rate also include charcoal & salt in alternate layers, 20mm bore GI pipe medium grade for watering and 40mm bore GI protection pipe (light grade), funnel, wire mesh, cast iron cover and frame etc, complete, all as specified or indicated and as directed including testing on completion complete all as specified and directed. Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with stand grouted in PCC. (iii) On testing after completion if the desired earth resistance is more than 2Ώ the earthing will be redone at no extra cost
All as per item ser No 42 here in before but for connected to galvanised earth lead wire of 4.0 mm dia by means of GI nuts bolts, check nuts and washers and connected to earthing test point drawn through 15 mm bore GI pipe medium grade for protection of GI earth lead wire including 20mm bore GI pipe medium grade for watering GI funnel
Material and labour for Insulation cover for overhead conductor a medium voltage wrap around line cover that provides retrofit insulation for overhead conductors to prevent electrical outages caused by trees or wildlife coming into the contact with distribution lines.It is manufactured from high quality non tracking polyolefin material. Insulation cover is designed to insulate existing bare lines without any extra cost. Installation is easy by using the split insulation tube tool which remains stationary at single location compete all as specified and directed. Note: (i) The quoted rate shall be included of all types accessaries which used to insulation cover for overhead conductor all as directed by Engr-in-Charge.
Supply and fixing in replacement MCCB TPN 630 Amps, 415 Volts, 50 KA, 4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete all as specified & directed
All as per item ser No 45 here in before but MCCB TPN 400 Amps, 415 Volts, 36 KA, 4 pole complete all as specified & directed
All as per item ser No 45 here in before but MCCB TPN 320/315 Amps, 415 Volts, 36 KA, 4 pole complete all as specified & directed
All as per item ser No 45 here in before but MCCB TPN 250 Amps, 415 Volts, 25 KA, 4 pole complete all as specified & directed
All as per item ser No 45 here in before but MCCB TPN 200 Amps, 415 Volts, 25 KA, 4 pole complete all as specified & directed
All as per item ser No 45 here in before but MCCB TPN 160 Amps, 415 Volts, 16 KA, 4 pole complete all as specified & directed
All as per item ser No 45 here in before but MCCB TPN 100/125 Amps, 415 Volts, 16 KA, 4 pole complete all as specified & directed
Material and labour for Detecting of fault in cable HT/LT with fault locator equipment which is capable to supply as per cable of HT/LT (11 KV/430 Volts) serviceable to cable with Straight through joint of size 70-300 Sqmm complete all as specified & directed Note:- (a) The HT fault which is detected through cable fault locator will only be paid under this item including transportation charges deemed to be included in the quoted rate. (b) Charge of cable fault locator and DG set, transportation charge deemed to be included in the quoted rate. (c) Earth fault locator will be provided by the contractor for even single HT fault and no delay on this account will be acceptable otherwise penalty will lived Rs 500/ per hour.
Supply and fixing in replacement of LT line separators 1100 V grade PVC spacer to separate LT conductor from each other 5 line as per IS complete all as specified & directed
All as per item ser No 53 here in before but 4 line complete all as specified & directed
Re-streching of loose over head ACSR conductor of any type/GI wire and repair of the broken conductors and adding new length (if required) in place of old and burnt conductor of any size on existing poles with proper sagging including winding with winding wire complete all as specified & directed. (Old conductor shall be reused where required for repairing broken length of conductor as directed by Engr-in-charge).
Trimming of Tree branches falls into OH lines of HT/LT & minimum clearance of 3 Mtr from branches ,proper shutdown will be taken and maintained in the register complete all as specified & directed
Material and labour in replacement of aluminium terminals (thimbles) after cutting the worn out/faulty cable end from LT pillar/panel box including necessary earth work for taking out the cable from loop line, returning, filling in and making cable lead by providing aluminium lugs including crimping with crimping tools in the existing LT cable 16 Sqmm 4 core upto 50 Sqmm & necessary connection complete all as specified & directed
All as per item ser No 57 here in before but size of LT cable 70 Sqmm 3.5 core upto 120 Sqmm 3.5 core complete all as specified & directed
All as per item ser No 57 here in before but size of LT cable 150 Sqmm 3.5 core upto 240 Sqmm 3.5 core complete all as specified & directed
All as per item ser No 57 here in before but size of LT cable 300 Sqmm 3.5 core upto 400 Sqmm 3.5 core complete all as specified & directed
Material and labour for shifting heavy items / excavation / cleaning areas / cleaning site by providing crane/hydra/excavators/tractors/trolley etc as required at site complete all as specified & directed
Material & Labour for spray painting on complete LT panels/Feeder Pillar Boxes of any size and any type two coats of synthetic enamel aluminium paint on outer shell and inner shell over a coat of red oxide including stand complete all as specified & directed
Repair of LT panel of any type and any size including replace of old unsv items such as busbar, insulaor, CT/PT coils, insulating sleaves, front and rear doors, door hinges, gland, lugs volt meter, ammeter, indicator, locking arrangement and internal copper wiring after cleaning of surface including removing rusted particles removing dust tightening nut, bolts welding complete all as specified and directed Note: (i) Cost of marking description on the front door as per direction of Engr-in-Charge is incl in quoted rate (ii) Cost of misc items like copper cable, lugs thimbles etc if required are included in quoted rates. (iii) Cost of welding works such as hinges, locking arrangement, door and angles are included in qouted rates.
Material & Labour for surface cleaning of LT steel tubular poles 9 mtrs long including removing rusted particles painting with two coats of synthetic enamel aluminium paint over a coat of red oxide including stand cross arms, bracing, supports,clamps eye hooks, security light bracket clamps etc providing black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paints incl repairing and painting on coping with cement base white paint complete all as specified & directed Note: (i) The quoted rate shall includes making of numbers on each LT pole as per direction of Engr-in-Charge. (ii) The quoted rates shall including the repairing of coping with cement / PCC
Material & Labour for cement base paint for Prestressed Concrete pole 9 mtr including black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paint and painting with two coats of synthetic enamel aluminium paint over a coat of red oxide including cross arms bracing supports, clamps, eye hooks, security light bracket, clamp etc incl repairing and painting on coping with cement base white paint complete all as specified & directed Note: (i) The quoted rate shall includes making of numbers on each LT pole as per direction of Engr-in-Charge. (ii) The quoted rates shall including the repairing of coping with cement / PCC
Material and labour for spraying chemical (Round up) on area to remove unwanted vegitation/grass at various locations complete all as specified & directed
Supply and fixing in replacement of on load change over switch with sheet steel Enclosure 415 V, 4 pole, 100 Amps capacity fixed on walls for electric supply distribution between main and DG set incl necessary connection of cable from LT panels to change over switches complete all as specified & directed
Supply and fixing in replacement of on load change over switch with sheet steel Enclosure 415 V, 4 pole, 200 Amps capacity fixed on walls/MS frame/pole/LT panel for electric supply distribution between main and DG set incl necessary connection of cable from LT panels to change over switches complete all as specified & directed
Supply and fixing in replacement of on load change over switch with sheet steel Enclosure 415 V, 4 pole, 320 Amps capacity fixed on walls/MS frame/pole/LT panel for electric supply distribution between main and DG set incl necessary connection of cable from LT panels to change over switches c complete all as specified & directed
Supply, installing, testing & commissioning in replacement of factory fabricated outdoor type feeder pillar board of size 700X600X500 mm , outer shell made out of 3.15 mm thick CRCA sheet and inner shell made out of 2 mm thick CRCA sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able with arrangement of pad locking on door 01 no of pad lock of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coated painting after 7-tank pre treatement control & power wiring with suitable size of copper conductor along with suitable gasket to make it dust/vermin proof and general construction confirming to IS:61439/2011 Part-1 and part -2 type test certificate with not less than IP-56 and breaking capacity 65 KA comprising of the following :- (a) MCCB 125 Amps TPN, 25 KA -01 No (b) Aluminium busbar of capacity 200 Amps with colour coated heat shrinkable sleeve and suitable hole for out going connection - Set of four. (c) Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cable lugs, sleeves, glands etc complete are included in quoted rates
All as per item ser No 72 here in before but size 1.4mX.9mX.5m, comprising of the following :- (a) TPN Aluminium bus bar 400 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators not less than 1 metre long. (b) MCCB 250 Amps, 25 KA 4 pole 415 Volts AC, adjustable type, (incoming)-01 No. (c) MCCB 125 Amp, 415 volt, 4 pole, breaking capacity 16 KA , (Outgoing)-03 Nos. (d) MCCB 63 Amp, 415 volt, 4 pole, breaking capacity 10 KA , (Outgoing)-02 Nos (e) MCB 32 Amp, 415 volt, TPN, breaking capacity 10 KA (Outgoing)-01 Nos (f) RYB indication LED type, 22.5 mm dia, protected with MCB SP 2 Amp showing 3 phase supply -03 Nos (g) Digital Ammeter of range 0-500 A, auxiliary voltage 230 volts -01 Nos (h) Volt meter of range 0-500 Volts, auxiliary voltage 230 volts -1 No (j) Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cable lugs, sleeves, cable glands, suitable CTs etc complete are included in quoted rates.
Notes for item Sr No. 70 to 75 (i) The quoted rate shall include minor items such as lugs, nuts, bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLSH cable conforming to IS-694. (iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE. (iv) The bus bar connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. (v) Cable will be entered in panles through glands. (vi) Cost of marking description and matter on the front door as specified and directed by Engr-in-Charge is incl in quoted rate.
Supplying and laying in replacement of synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 10m x 1m complete all as specified & directed
Material & Labour for cable jointing kit 11 KV (Earthed) grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm incl taking down old unsv HT joint complete all as specified & directed
Material & Labour for cable jointing kit 11 KV (Earthed) grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm incl taking down old unsv HT joint complete all as specified & directed
Material & Labour for cable end termination jointing kit HT 11 KV grade earthed system (heat shrinkable) outdoor type complete with jointing material suitable for HT XLPE cable 50-95 sqmm 3 core 11 KV grade earthed system incl taking down old unsv HT joint complete all as specified & directed .
Material & Labour for carrying out numbering of electric panels and LT poles with radium stickers from 01 to 300 in yellow background & black letters complete all as specified & directed
Material and labour in replacement of broken earth pit of size 300x300x300 mm made of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia TMT bars @ 100 mm centre to centre both ways with handle made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers as required at site with testing result complete all as specified & directed.
Material and labour repairs of stay by tightening of stay wire after untying the conductor spans from the poles to make correct tensions and maintain verticality of poles, including re-jointing the conductors in position with new binding wire complete all as specified & directed
Repairing of existing unserviceable PCC coping of LT/HT pole by breaking completely, material and labour for PCC 1:2:4 type B1, (using 20mm graded crushed stone aggregate) of size 600X600X300mm including form work and applying two coats of white wash complete all as specified & directed.
Supply, fixing, installing and testing in replacement of Hot Air Oven with blower/fan to heat up Silica gel granules removed from transformers which had turned pink and had absorbed moisture upto 50 Deg C to 200 Deg C incl trays of size 10” x 10” minimum complete all as specified & directed.
Supply, fixing and testing in replacement of three phase Multi-Function meter to measure essential electrical parameters such as voltage, current, power factor, frequency, and energy consumption to measure real-time data, enabling precise power quality assessment, load management, and energy efficiency complete including re-wiring if required complete all as specified & directed. Make: Secure/Selec / Siemens
Taking down old unserviceable Indicator any type any colour and supply and fixing new Indicator red/yellow/green including making electrical connection with suitable size of copper lugs duly crimped complete all as specified & directed
Taking down wooden chowkats or frames area not exceeding 1.50 Square metre (w/o taking off shutters from frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish complete all as specified and as directed.
Supply and fixing steel window box type using ERW hollow 'P' section comprising double frame for and including gauged and glazed Skelton shutter 30mm thick, jointed internally with flat iron 25x3mm complete including hinges, handle, tower bolts, stops, lugs etc. all as shown on CECZ Chandigarh drawing No.. TD-219(c) sheet 1/3 to 3/3 and TD-220(c) sheet 1/3 to 3/3 as applicable complete all as specified & directed. Note: (i) For the purpose of measurement and payment double shutter with frame shall be considered as one unit. (ii) Unit rate quoted against this item shall also include the iron mongery and grill 10 mm square bar irrespective of whatever shown on drawing. (iii) Glazing, wire mesh and painting shall be measured and paid for separately.
Supply and fixing stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staple or fixing with beads to wooden joinery when fixed in panels of joinery, complete all as specified & directed
Supply and fixed for sheet glass 3mm thick tinted, ordinary quality and glazing with oil putty, in square n.exc 0.5 Sqm each pane and glazing with oil putty to steel window and with wooden beads to wooden shutters, c complete all as specified & directed
Dismantling of brick work or stone masonary, precast cement concrete walling built in cement mortar including all quoins, arches, pillars etc. complete all as specified & directed
Material and labour for brick work with sub class ‘B’ bricks burnt, straight or curved on plan exceeding 6 metre mean radius built in cement mortar (1:6), complete all as specified & directed.
Material and Labour for Brick work with sub class ‘B’ bricks (Except Bricks), straight or curved on plan exceeding 6 metre mean radius, built in cement mortar (1:6), complete all as specified & directed (Note- The serviceable bricks obtained from Serial item No- 93 Shall be used after removing mortar, cleaning the bricks with water, etc.)
Material and labour for vibratory compactive, precast cement concrete rubber moulded, coloured ( except grey colour), interlocking designer paver blocks in Milano shape, comfirming to IS-15658-2006 of 60 mm thickness, M-35 grade, as in path, harding standing, etc laid over and including 25 mm compacted sand cushioning, including including surface excavation over area n. exc. 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil and removing excavated soil exc. 50 mtr but n. exc. 250 mtr, complete all as specified & directed
Material and labour for 75mm thick PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in sub base complete all as specified & directed
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified & directed
Material & Labour for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finishing the surface fair and even without using extra cement complete all as specified & directed
Material & Labour for preparation and applying three coats of exterior emulsion paint on new /old plastered surface of wall complete all as specified & directed
Material & Labour for 100mm thick PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in sub base complete all as specified & directed
Supply and fixing in replacement LT Air Circuit Breaker, 4 pole, manual drawout type, 415 volt with microprocessor release IPRE, 630 Amp, Icu=Ics=Icw (1s)=50 KA, neutral overload protection , inbuilt temp protection upto 90 degree Celcious, rotatable terminals for horizontal/vertical orientation, fast operation and fixing the same in existing panel board including necessary modification with angle iron and plain sheet complete all as specified & directed
Material & labour for servicing / repair of Isolating LT ACBs 630-1000 Amps capacity and testing its operation, tripping devices , mechanical system , setting the ACBs, right clearing, servicing and recharging complete unit. The Make of existing ACBs are Legrand/Crompton/ Schenider/Havells/ABB ( Note : Provision of new spare parts as required shall be measured and paid separately.)
On/Off Button ACB
Spring Charge Indicator ACB
Trip indication switch
Under voltage release
Electronic protection Units
Real terminals flat connections with bar
Shunt Trip/Closing Coil (415V)
Earth fault relay 3 phase 3 wire
Aux contact block 3 No 3 NC
Micro switch for unserviceable trip indication
Phase barrier 3 P
Mechanical Interlock
Fixed Arcing contact 3P
Moving Arcing contact 3P
Rectification of complaints under Sector "B" area of security light, street light, hanger light, flood light and high mast lights and allied works by attendng daily complaints including Sunday and other holidays for round the clock and making the same serviceable in all respects alongwith replacement of any major part but including small length of cable (not more than 20 mtr), adhesive tape and other connected minor accessories shall also include to visual inspection of OH lines, Earth Resistance of street poles etc. Quoted rate also include excavation of faulty cable/all type lights are making seviceable with accessories of all nature like No light, faulty insulator, broken conductor & cable fault , burnt out MCCB`s, MCBs, isolators, switch fuses, service cables etc complete all as directed to the entire satisfacation of Engineer-in-charge. Note ‘A’ :- (i) Any complaint left unattended by the electrician will be communicated to the JE in-charge /AGE E/M with reason. No charge will be paid for the per complaint till the complaint is resolved. (ii) New material /stores provided for completing the job shall be measured and paid for separately under relevant items of BOQ. (iii) Contractor shall provide all type of T&P of LT street lights network, bamboo ladder with safety gloves to each electrician for attending the external electric complaints. (iv) Contractor shall provide the complaint register 200 pages – 3 No, complaint book with 100 slips- 5 No. Booklets serially numbered in triplicate. (v) Contractor will provide 01 No. Experienced Electrician having minimum 5 years experience ( 01x one shifts per day) and 01 No. Helper having minimum 2 years experience ( 01 x one shifts per day) including Sundays and Holidays to attend HT Complaints. (vi) Contractor will provide well experienced and well conversant of one person for lodging the complaint in complaint cell of each power house during working hours from 0900hrs to 1700hrs on all working days including Sunday & all Holidays. (vii) The Contractor will provide insurance cover of minimum Rs 5 lakh per head under IE Rules 2003 and Minimum wages Act. (viii) The Electrician and helper will be interviewed by JE E/M /Engr-in-charge for verification of experience, character and sound mind and body.
Supply and fixing in replacement of rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment Fe-290 (Gde E- 165) for existing LT panel doors/gates complete all as specified & directed.
Supply and fix in replacement of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled red, with letters, figures and conventional skull and bones in signal white colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed.
Taking down old unserviciable board and supply and fixing of Retro reflective sign board type route indicator of size 600 x 750 sqmm made of ACP sheet of 3mm thick ACP sheet shall be fixed on MS frame with legs of MS angle section 35mm X 35mm X 4mm grouted in PCC 1:3:6 type C-1, 750mm above the ground level and 600mm below the ground level. The background of board to be provided with red colour, letters and border with white retro reflective tape. Same description shall be mentioned on both sides of ACP sheet complete all as specified and directed. NOTE:- (i) Excavation, earth work, PCC, nuts, bolts, fasners, paint on MS frame and legs shall be included in quoted rates by contractor. (ii) The size of letters and description shall be all as per sample approved by Engr-in-Charge.
Supply and fixing in replacement of cable route indicator or cable joint mark for 1100 volts made out of mild steel 100mm dia 6mm thick plate welded to 40x40x6mm angle iron 60 cm long embeded in PCC 1:3:6 type C-2 (using 20mm graded stone aggregate) block size of 150mm x 200mm x 200mm including applying two coats of synthetic enamel paint over a coat of redoxide primer on steel surfaces complete all as specified & directed
Material & Labour in replacement of steel nuts, bolts, washers of any size required at site complete all as specified & directed
Material & Labour for disconnecting and connecting of LT service wires and XLPE cables of any type and any size from LT panel, MCCBs, DBs, over head conductor, LT poles, street light timer including replacement of old unsv items such as nuts, bolts, thimbles, insulating seleaves and existing misc items etc, and after cleaning and removing of corbon on cables end surface including removing rested particles removing dust tightening nut, bolts complete all as specified & directed Note : (i) Cost of all tools and ladder required for maintenance of LT service wires and XLPE cable end connection and disconnection is incl in quoted rate (ii) Cost of misc items like nuts, bolts, thimbles, insulating seleaves etc if required are included in quoted rates.
Supply & Fixing in replacement of extended spreaders link should be installed both side with exisitng/new MCCBs 4P/3P of any capacity with existing LT panels complete all as specified & directed
Supply, fixing and testing in replacement of auto day/night on and off photo cell, LDR sensor switch 6 amps for lighting on/off, water proof 220 volt 50 Hz, AC supply, Model No Quick Sense QS-301 complete with all accessories internally pre-wired including connection with 1.5 Sqmm copper conductor from main supply to sensor, sensor to fittings complete all as specified & directed
Supply & Fixing in replacement of bracket made out of GI tubing single piece not welded, bended at proper angle of size 40mm dia, light grade 1.5 mtr long including painting with aluminium paint over one coat of red oxide primer to the bracket complete all as specified & directed
Supply & Fixing in replacement of MS clamp suitable for holding street light bracket on steel/PCC pole made out of 40 mm x6 mm thick flat iron with M.S nuts bolts 50 mm long 10 mm dia -3 Nos with flat washer 3mm thick -02 No for each including painting with aluminium paint over one coat of red oxide primer to the M.S clamps complete all as specified & directed
Note:- Amount of credit of Rs. 151541.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in PDFf form which will be deducted offline while acceptance of tender.
KULWANT SINGH
M/S Sonu Traders
R. P. Suppliers and Construction Co.
Mohinder Pal and Sons
u and v engineers and consultants
Saurav Enterprises
kapil enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .