Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.2 LAccepted-AOC HARI BHAVAN NORTH ARYAD ALAPPUZHA | ₹10.2 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹10.6 LRejected-AOC | ₹10.6 L | L2 | Rejected-AOC Second lowest bidder |
| 3 | L3₹11.2 LRejected-Finance | ₹11.2 L | L3 | Rejected-Finance Third Lowest Bidder |
| 4 | L4₹11.5 LRejected-Finance | ₹11.5 L | L4 | Rejected-Finance Highest Bidder |
| Sl No | Description | Qty | Unit | THEJUS ELECTRICALS L4 | SYNERGY POWER TECH L3 | AJITH L2 | HARISH AND CO L1 |
|---|---|---|---|---|---|---|---|
| 1.00ON grid solar | |||||||
| 1.00 | OD21859/2025-2026:Supply and providing wall mounted on grid solar Power Conditioning Unit (PCU) of
200-1000 V DC Input voltage range or nearest range and 400V AC, three phase, 4
wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency
not less than 97%, total harmonic distortion less than 3% and suitable for ambient
temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency
level to suit the Grid Voltage Frequency and adustiable for connecting time to grid as
per KSEB norms, including Data Monitoring System complete with accessories
wifi/LAN connecting and connected application software etc. fixing on wall using
wall brackets and giving all connection as required | 15 | kW | 8,168.49 ₹1.2 L | 8,800 ₹1.3 L | 7,522.44 ₹1.1 L | 8,000 ₹1.2 L |
| 1.00 | OD46846/2025-2026:Supply and providing topkon Solar Photovoltaic Module Mono Perc Half Cut of capacity 590 Wp or nearest size, manufactured in India, conforming to IS 14286/IEC 61215,IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. fixing on existing steel frame work using nut bolts/screws etc in suitable direction at site condition and giving connection and inter connection wire tied using suitable steel wire tie as per the system string design and direction of department staff | 30 | each | 22,795.96 ₹6.8 L | 24,500 ₹7.3 L | 20,993.03 ₹6.3 L | 20,000 ₹6 L |
| 1.00 | OD21860/2025-2026:Supply and providing wall mounted AC DB for on grid solar system for connecting
Inverter AC side consists of a). Poly carbonate Enclosure IP65 protection with
trasperant front cover with hinged door and termination arrangement, b). SPD
Up1.5kV,Up 335VDC In 20kA, Imax 40kA and giving internal connection using
suitable wire, c). 6-32A 4Pole AC MCB for outgoing side, giving all connection and
DB fixing on wall using suitabel screws and plugs ets as required. | 1 | each | 8,798.53 ₹8,798.53 | 9,500 ₹9,500 | 8,102.66 ₹8,102.66 | 7,000 ₹7,000 |
| 1.00 | OD21861/2025-2026:Supply and providing wall mounted DC DB for on grid solar system for connecting
2Nos solar panel string and DB consists of a). Thermoplastic Enclosure IP65
protection with transparent front cover with hinged/screws door and termination
arrangement, b). 2set 20A DC Fuse and Holder for +ve and connector for -ve
incomer side, c). 2set SPD 1000V DC Up1.9kV,Ucpv 585VDC, In 15kA, Imax 40kA
and giving internal connection using suitable wire, d). 2set of 10 - 20A 2Pole DC MCB for outgoing side, giving all connection and DB fixing on wall using suitable
screws and plugs ets as required. | 1 | each | 11,196.55 ₹11,196.55 | 12,000 ₹12,000 | 10,311.02 ₹10,311.02 | 10,000 ₹10,000 |
| 1.00 | OD21851/2025-2026:Supplying and drawing 1run x 4 sq. mm PVC insulated tinned copper conductor, single core Solar DC cable in the existing surface / recessed steel/ PVC conduit as required. | 225 | metre | 86.07 ₹19,365.75 | 60 ₹13,500 | 79.26 ₹17,833.50 | 75 ₹16,875 |
| 1.01 | OD21854/2025-2026:Supply & installation of dust and vermin proof, 3 Phase Syntax Meter Board( GS-MB- 6545) and to fix KSEB meters, fuse units etc as required including fixing it on wall, making good the damages colour washing etc. as required. | 1 | each | 6,862.74 ₹6,862.74 | 7,250 ₹7,250 | 6,319.96 ₹6,319.96 | 6,000 ₹6,000 |
| 1.01 | 2.10.5:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Triple pole and neutral | 1 | each | 1,305.32 ₹1,305.32 | 1,300 ₹1,300 | 1,202.08 ₹1,202.08 | 1,000 ₹1,000 |
| 1.01 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415
volts, residual current circuit breaker (RCCB), having a sensitivity current 30
milli Amperes in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
40 amps | 1 | each | 3,387.75 ₹3,387.75 | 3,300 ₹3,300 | 3,119.81 ₹3,119.81 | 3,200 ₹3,200 |
| 1.01 | OD21853/2025-2026:Supplying and fixing Three phase 4wire KWh meter, 415V, 10 - 100 A range ,electronic type in the existing meter board complete with connections, testing and commissioning etc. as required (including testing if required, test certificate for submitting KSEB). | 1 | each | 7,244.54 ₹7,244.54 | 7,100 ₹7,100 | 6,671.57 ₹6,671.57 | 7,000 ₹7,000 |
Tender Value
₹12.5 L
EMD Value
₹31,136
Closing Date
3 Jan 2026, 4:00 pmClosed
Assistant Executive Engineer
O/o Assistant Executive Engineer, PWD Electrical Subdivision, Civil Station, Alappuzha
DEPOSIT-On Grid Solar-e court phaseIII-Implementation of solar power plant for District Judiciary- Supply and installation of On Grid Solar and connected Electrical works at Court Complex, Mavelikkara, Alappuzha-General Electrical Work
2025_PWD_823316_1
PWD/BLDG/TR/8000/2025_6_1_1/1
Open Tender
Electrical Works
150 days
Mavelikkara
Please refer tender documents
12 documents required · 12 mandatory
₹2,760
₹31,136
21 Feb 2026
22 Dec 2025
5 Jan 2026
22 Dec 2025
3 Jan 2026
22 Dec 2025
Amount
ON grid solar
OD21859/2025-2026:Supply and providing wall mounted on grid solar Power Conditioning Unit (PCU) of 200-1000 V DC Input voltage range or nearest range and 400V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency and adustiable for connecting time to grid as per KSEB norms, including Data Monitoring System complete with accessories wifi/LAN connecting and connected application software etc. fixing on wall using wall brackets and giving all connection as required
OD46846/2025-2026:Supply and providing topkon Solar Photovoltaic Module Mono Perc Half Cut of capacity 590 Wp or nearest size, manufactured in India, conforming to IS 14286/IEC 61215,IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. fixing on existing steel frame work using nut bolts/screws etc in suitable direction at site condition and giving connection and inter connection wire tied using suitable steel wire tie as per the system string design and direction of department staff
OD21860/2025-2026:Supply and providing wall mounted AC DB for on grid solar system for connecting Inverter AC side consists of a). Poly carbonate Enclosure IP65 protection with trasperant front cover with hinged door and termination arrangement, b). SPD Up1.5kV,Up 335VDC In 20kA, Imax 40kA and giving internal connection using suitable wire, c). 6-32A 4Pole AC MCB for outgoing side, giving all connection and DB fixing on wall using suitabel screws and plugs ets as required.
OD21861/2025-2026:Supply and providing wall mounted DC DB for on grid solar system for connecting 2Nos solar panel string and DB consists of a). Thermoplastic Enclosure IP65 protection with transparent front cover with hinged/screws door and termination arrangement, b). 2set 20A DC Fuse and Holder for +ve and connector for -ve incomer side, c). 2set SPD 1000V DC Up1.9kV,Ucpv 585VDC, In 15kA, Imax 40kA and giving internal connection using suitable wire, d). 2set of 10 - 20A 2Pole DC MCB for outgoing side, giving all connection and DB fixing on wall using suitable screws and plugs ets as required.
OD21851/2025-2026:Supplying and drawing 1run x 4 sq. mm PVC insulated tinned copper conductor, single core Solar DC cable in the existing surface / recessed steel/ PVC conduit as required.
OD21854/2025-2026:Supply & installation of dust and vermin proof, 3 Phase Syntax Meter Board( GS-MB- 6545) and to fix KSEB meters, fuse units etc as required including fixing it on wall, making good the damages colour washing etc. as required.
2.10.5:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
OD21853/2025-2026:Supplying and fixing Three phase 4wire KWh meter, 415V, 10 - 100 A range ,electronic type in the existing meter board complete with connections, testing and commissioning etc. as required (including testing if required, test certificate for submitting KSEB).
OD21849/2025-2026:Supply and wiring with PVC insulated stranded single core copper conductor cables for interconnecting the control devices/ equipment's including the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 10Sqmm single run
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
90.14.11.14:MCCB AccessoriesSupply and fixing rotary handle, Direct type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A
OD21855/2025-2026:Supplying and fixing Three phase 4wire KWh CT Net meter, 415V, electronic type in the existing meter board complete with connections, testing and commissioning etc. as required for charging On grid plant after dismantling the existing KWH meter (including testing if required, test certificate for submitting KSEB).
OD69926/2025-2026:Supply and fixing 100/5 , class 0.5s, 5VA metering CT giving connections etc as required
90.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap
90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid
90.6.4.54:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 4 Run
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
90.12.5.41:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD21850/2025-2026:Supply and fixing 2 x 25mm X 3 mm copper strip test joint for the earthing system.
OD21856/2025-2026:Supply and providing 25x3mm brass bolt
OD21848/2025-2026:Supply and providing 25x6mm brass bolt
OD21857/2025-2026:Supply and providing 12x3mm brass bolt
OD21852/2025-2026:Supply and providing Copper Bounded lightning arrester single spike " Air-termination rod " are placed on top of the structure using suitable base plate and nut bolt and giving connection to existing lightning down conductor etc as required
90.16.3.9:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip
90.3.17.2:Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.40 mm dia GI pipe
OD21862/2025-2026:Supply and connecting MC4 Wire Connector Male/Female for Solar Panels, IP67 Waterproof Cable Connectors IP68 rating, rated voltage - 1500VDC (IEC) / DC (UL), Ambient Temperature - -40°C to +90°C (EC) Contact Material: Brass/Copper, Tin-Plated
OD21863/2025-2026:Supply and fixing D-Link DAP-1325 Router 300 Mbps WiFi Range Extender or Equivalent Type: Range Extenders/Repeaters,300 Mbps Speed,Frequency: 2.4 GHz,External Antenna
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
OD21846/2025-2026:Charges for preparation of Electrical Drawing per A2 sheet first copy for sanction from Electrical inspectorate if required (DG approved installation hence additional and alteration required )
OD21847/2025-2026:Copying charges for additional copies per A2 sheet
Civil
10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
AJITH (BID ID -2451397)
SYNERGY POWER TECH (BID ID -2450628)
THEJUS ELECTRICALS (BID ID -2450082)
Bidder Name
AJITH
HARISH AND CO
SYNERGY POWER TECH
THEJUS ELECTRICALS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_1379970.xls
BOQ • 0.26 MB
viewsbd.pdf
Tender Documents • 2.96 MB
8000MOM.pdf
Other Document • 0.14 MB
Download all tender documents and submit your bid