| 1 | L1₹37.7 LAccepted-AOC HOUSE NO 8 589 BEHIND PHC HOSPITAL OLD BUS STAND KORBA KORBA CHHATTISGARH 495678 | 495678 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹37.7 L+₹8,069 (0.21%)Rejected-Finance SPECIAL 1 INDUSTRIAL ESTATE NEW POWER HOUSE ROAD JODHPUR 342003 | JODHPUR | RAJASTHAN | 342003 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹39.5 L+₹1.8 L (4.75%)Rejected-Finance MANDI PILIBANGA HANUMANGARH RAJ | HANUMANGARH | RAJASTHAN | 335063 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹39.5 L+₹1.9 L (4.92%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹40.3 L+₹2.6 L (6.97%)Rejected-Finance NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹39.9 L
EMD Value
₹79,860
Closing Date
24 Sept 2022, 6:00 pmClosed
Garrison Engineer Banar
Garrison Engineer Banar, Jodhpur-342027
REPAIR/MAINT OF LT CABLES, PANELS, FEEDER PILLAR BOXES, POLES AND CONNECTED ITEMS AT ARMY AREA BANAR
2022_MES_546518_1
8822/34/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Banar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer Banar
₹79,860
Yes
10 Nov 2022
20 Aug 2022
26 Sept 2022
20 Aug 2022
24 Sept 2022
10 Sept 2022
Amount
Supplying, laying, jointing testing and connecting in replacement 10 Sqmm 2 core XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 Part I, suitable for LT 1100 Volt system,laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe including jointing & testing complete all as specified. Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule.
All as per Ser No 1.00 above but size 16 sqmm 4 core
All as per Ser No 1.00 above but size 25 sqmm 4 core
All as per Ser No 1.00 above but size 35 sqmm 3.5 core
All as per Ser No 1.00 above but size 50 sqmm 3.5 core
All as per Ser No 1.00 above but size 95 sqmm 3.5 core
All as per Ser No 1.00 above but size 120 sqmm 3.5 core
All as per Ser No 1.00 above but size 150 sqmm 3.5 core
All as per Ser No 1.00 above but size 240 sqmm 3.5 core
Supply and fixing in replacement GI Pipe light grade 80 mm bore with necessary accessories/ fittings bracing with pol/wall by FI clamps made with 32x6mm for cable protections/pole for crossing of culverts/nallah and all as specified and directed sizes:-
All as per ser item No 10.00 above but of size 50 mm bore.
All as per ser item No 10.00 above but of size 40 mm bore.
M&L for Cutting the road / hard standings and excavating in trenches not exceding 0.40 mtr wide and not exc 0.80 mtr deep across the road for laying cable including making good the excavated portion by means of PCC 1:2:4, type B1 using 20mm graded stone aggregate complete and matching the level with the surroundings all as directed.
Arranging fault locating machine to locate the fault in underground elect power cables of any length and any type of 1100 Volts grade LT cable and pin point the fault and testing of the cable after locating fault and cutting the cable at fault to check healthiness of cable before and after fixing the joint including excavation and earth work in any type of soil complete. Note : Cable joints and cable shall be measured and paid separately under respective item of Schedule 'A'.
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade suitable for 16- 35 Sqmm x 3.5 core/4 core and including taking out cable from faulty portion in any situation/position complete all as specified.
All as per ser item No 15.00 above but of size 50-70 Sqmm x 3.5 core
All as per ser item No 15.00 above but of size 95-120 Sqmm x 3.5 core
All as per ser item No 15.00 above but of size 150-185 Sqmm x 3.5 core
All as per ser item No 15.00 above but of size 240-300 Sqmm x 3.5 core
Supply, fixing and testing end joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade suitable for 50- 70 Sqmm x 3.5 core and including taking out cable from faulty portion in any situation/position complete all as specified.
All as per ser item No 20.00 above but of size 95-120 Sqmm x 3.5 core
All as per ser item No 20.00 above but of size 150-185 Sqmm x 3.5 core
All as per ser item No 20.00 above but of size 240-300 Sqmm x 3.5 core
Supply and fixing in replacement of cable gland for LT panel/feeder pilar up to 50 Sqmm cable complete all as specified.
Supply and fixing in replacement of cable gland for LT panel/feeder pilar for 70 sqmm cable to 240 Sqmm cable complete all as specified.
Supply and fixing in replacement of cable gland for LT panel for 300 sqmm cable to 400 Sqmm cable complete all as specified.
Material and labour for disconnecting power supply from LT ACB of cap. 800/1000/1500 Amps for repair works , taking out trolly unit & complete servicing of the same through decarbonising , cleaning the male /female isolating contacts, lubricating moving part , cleaning with CRC removing dust particles from bus bar chamber, spout gear mechanism and moving parts, repair to motor charge spring mechanism, tightening all nuts and bolts of entire trolley, checking proper operation of trolly including inserting trolley inside, testing and putting on load complete all as specified and directed .
Supply, installing, testing and commissioning in replacement of factory made and tested Bus bar chamber outdoor type with canopy made out of 3.15 mm CRCA MS sheet, and 40x40x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, with apron for cable entry closing locking arrangement of size not less than 400mm x 400mm x 300mm with and including 4 Nos 400 Amps aluminium bus bar, 250 Amp MCCB, 4 pole, 25 KA, 415 Volt 50 Hz including excavation, earth work and platform for the Bus bar chamber with PCC 1:4:8 type D-2 with 40 mm graded stone aggregate, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded sotne aggregate on top and grouting bolts etc for Bus bar chamber complete all as specified. The platform shall be such that it is of a height 60 cm above the nearest road level.
Supply and fixing in replacement of change over switch on load, 4 pole, 415 Volts 50 Hz 160 Amps open execution type mounted on existing any type/description of LT Panel/feeder pillar with minor modifications of existing LT Panel/Feeder Pillar box to fix and connecting terminals and making fresh connections of cables all as specified.
All Asper Srl Item No 29.00 above but within sheet steel enclosure of 250 Amps Capacity
All Asper Srl Item No 29.00 above but within sheet steel enclosure of 400 Amps Capacity
Suupply and Fixing in replacement of Mild steel sliding door bolts plate type, stove enamelled black, with bright bolt not less than 12mm dia, 200mm long bolt with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed on front side door of LT panel board and all as specified.
Material and labour in replacement the broken hinges of LT panel shutters with stainless steel hinges of 200mm long by welding/bracing with nut bolts of existing LT panels shutters of any descreption and all as specified.
Material and labour for scraping the rusted surface of LT panel/feeder pillar any descreption/size and applying the primer coat of red oxide and painting overall surface of LT Panels/feeder pillars with two coats of super enamal paintf flint grey/sky blue/existing colour with sparygun including writing of feeder pillar numbers in appropriate size of letters as directed.
Material and Labour for replaceing the heatup/nacked cable ends by cutting the nacked/heatup portion and reconnect the cable by excavating the loop and making connection tight by replacing the suitable size of heavy duty lugs with new nut bolts and washers and all as specified and directed.Note : (i) Cable end joints/Lugs will measure and paid under relevent item of Sch. (ii) Total incoming and outgoing cable ends of each panel will be measured as a one job.
Supply & fixing Aluminium terminal (lugs) suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade 16- 35 Sqmm x 3.5 core/4 core and including taking out cable from faulty portion in any situation/position complete all as specified and directed
All as per ser item No 36.00 above but of size 50-70 Sqmm x 3.5 core
All as per ser item No 36.00 above but of size 95-120 Sqmm x 3.5 core
All as per ser item No 36.00 above but of size 150-185 Sqmm x 3.5 core
All as per ser item No 36.00 above but of size 240-300 Sqmm x 3.5 core
Repair & maintenance of LT Panel board in door/outdoor type comprising of MCCBs as In coming and outgoing with digital metering and control wiring by disconnecting all incoming and out going connection, opening of LT cable incl refixing of cables after proper lugging and glands complete. Cleaning of all compartment from in side and out side including using anti rust spray and checking and repair of all controls, switches, meters. etc (if found diffective) and painting complete panel board with two coat of synthetic enamel paint over a coat of red-oxide paint, after necessary scrapping and denting (Tint of paint colour shall be approved by GE). Refixing of panel board on new angle iron stand made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6 B2 type complete all as specified. Note: 1. The MCCBs,MCBs will be measured and paid saperately in respective Sch A item. 2. The angle iron frame & PCC work is deemed to be included in above quoted rates. The level of stand kept 60 cm above G.L.
Supply and fixing in replacement of MCCBs with thermal and magnetic release adjustable over load setting 0.8 to 1.0% and short circuit setting 0.6 to 1.0% of capacity 160 Amps, 4pole 415 volts 36KA fixed in any type of existing LT panel/Feeder piller etc complete all as directed.
All as per ser item No 42.00 above but of capacity 200 Amps,4pole 415 volts 36KA
All as per ser item No 42.00 above but of capacity 250 Amps,4pole 415 volts 36KA
All as per ser item No 42.00 above but of capacity 350 Amps,4pole 415 volts 36KA
All as per ser item No 42.00 above but of capacity 400 Amps,4pole 415 volts 36KA
Supply and installation, testing and commissioning in replacement LT feeder pillar box suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC Supply System confirming to IS:8623/93, outdoor type floor mounting along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 1000A, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The feeder pillar box shall be front and rear opening and having inner & outer shells. The inner shell duly compartmented for each control gear, including Powder coating internal & external surfaces. All the covers shall be provided with suitable locking arrangements, mounted on angle iron stand fixed at 60 cm from the ground level made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6, and comprising of the following controls gears (Note: (i) The size of Feeder pillar box should not be less than 1100x1050x450mm, (ii) Cost of PCC platform 50mm thick 1:2:4 Type B-1 over 75mm thick sub base 1:5:10 type E-2 using 40mm graded stone aggregate is inclusive in the rate quoted for this item. (iii) Drawing of LT Panel shall be submitted the contractor for approval of Accepting Officer before placing order. (A) INCOMING (a) MCCB 4 Pole 415 Volts thermal adjustable type 36 KA 630 Amp rating-01 No (b) On load change over switch,415 V,4P of capacity 400 A-01 Nos (b) Ammeter 0 to 800 Amp digital type with suitable ratio of CT's. (c) Voltmeter 0 to 500 volts digital type having arrangement to check phase to phase, phase to neutral (d) RYB LED indicating lamp panel mounting type (Set of three) - 01 No. (e) Bus bar chamber having insulated aluminum bus bar 1000 Amp and neutral. (f) Chamber of suitable size for incoming and out going cablees with arrnging of suitable size cable glands. (B) OUTGOING (a) MCCB 4 Pole 415 Volts thermal adjustable type 36 KA 250 Amp rating -01 No (b) MCCB 4 Pole 415 Volts thermal adjustable type 36 KA 200 Amp rating -02 No (c) MCCB 4 Pole 415 Volts thermal adjustable type 36 KA 160 Amp ratingg-02 No
Supply and installation, testing and commissioning in replacement LT feeder pillar box suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC Supply System confirming to IS:8623/93, outdoor type floor mounting along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 600A, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The feeder pillar box shall be front and rear opening and having inner & outer shells. The inner shell duly compartmented for each control gear, including Powder coating internal & external surfaces. All the covers shall be provided with suitable locking arrangements, mounted on angle iron stand fixed at 60 cm from the ground level made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6, and comprising of the following controls gears (Note: (i) The size of Feeder pillar box should not be less than 1100x1050x450mm, (ii) Cost of PCC platform 50mm thick 1:2:4 Type B-1 over 75mm thick sub base 1:5:10 type E-2 using 40mm graded stone aggregate is inclusive in the rate quoted for this item. (iii) Drawing of LT Panel shall be submitted by the contractor for approval of Accepting Officer before placing order. (A) INCOMING (a) MCCB 4 Pole 415 Volts thermal adjustable type 36 KA 400 Amp rating-01 No (b) Ammeter 0 to 500 Amp digital type with suitable ratio of CT's. (c) Voltmeter 0 to 500 volts digital type having arrangement to check phase to phase, phase to neutral (d) RYB LED indicating lamp panel mounting type (Set of three) - 01 No. (e) Bus bar chamber having insulated aluminum bus bar 600 Amp and neutral. (f) Chamber of suitable size for incoming and out going cablees with arrnging of suitable size cable glands. (B) OUTGOING (a) MCCB 4 Pole 415 Volts thermal adjustable type 36 KA 200 Amp rating -01 No (b) MCCB 4 Pole 415 Volts thermal adjustable type 36 KA 160 Amp rating -02 No (c) MCCB 4 Pole 415 Volts thermal adjustable type 16 KA 100 Amp rating-01 No
Supply and installation, testing and commissioning LT feeder pillar box suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC Supply System confirming to IS:8623/93, outdoor type floor mounting along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 400A, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The feeder pillar box shall be front and rear opening and having inner & outer shells. The inner shell duly compartmented for each control gear, including Powder coating internal & external surfaces. All the covers shall be provided with suitable locking arrangements, mounted on angle iron stand fixed at 60 cm from the ground level made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6, and comprising of the following controls gears (Note: (i) The size of Feeder pillar box should not be less than 1100x1050x450mm, (ii) Cost of PCC platform 50mm thick 1:2:4 Type B-1 over 75mm thick sub base 1:5:10 type E-2 using 40mm graded stone aggregate is inclusive in the rate quoted for this item. (iii) Drawing of LT Panel shall be submitted by the contractor for approval of Accepting Officer before placing order. (A) INCOMING (a) MCCB 4 Pole 415 Volts thermal adjustable type 36 KA 250 Amp rating -01 No (b) Ammeter 0 to 500 Amp digital type with suitable ratio of CT's. (c) Voltmeter 0 to 500 volts digital type having arrangement to check phase to phase, phase to neutral (d) RYB LED indicating lamp panel mounting type (Set of three) - 01 No. (e) Bus bar chamber having insulated aluminum bus bar 400 Amp and neutral. (f) Chamber of suitable size for incoming and out going cablees with arrnging of suitable size cable glands. (B) OUTGOING (a) MCCB 4 Pole 415 Volts thermal adjustable type 36 KA 100 Amp rating -01 No (b) MCCB 4 Pole 415 Volts thermal adjustable type 36 KA 160 Amp rating -01 No (c) Isolator, TPN, 415 Volts 16 KA 63 Amp-02 No
M&L in replacement of earthing with Galvanised Steel earthplate of size 60x60cmx6mm thick electrode and 32x6mm GI strip as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to 32x6mm earth strip by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I, connected to earth test terminal point all as specified or as indicated including testing on completion (Rates inclusive of neccessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc. all as required at site for complete earthing). Note: Testing of earthing shall be carried out after completion of earthing.Payment for earthing shall be admissible after production of documents of satisfactory test result by the contractor.
M&L in replacement of GI strip of size 32x6 mm including mounting on PVC/Porcelain insulators on wall and burried in ground depth not less than 60 cm in ground complete all as specified and directed by Engineer-in-Charge.
Labour for cutting and removing grass, vegetation, bushes/shrubs etc from surrounding of 02 Pole/ 4 Pole structure and LT/ HT Panel E/M installations and removing all rubbish and dressing the gravel/soil and spaying the one time herbicide approved brand (Roundup/Noweed) to prevent the further vegetation and all as specified and directed. Note: Extent of Area to be cleared shall be decided by Engr-in-Charge.
Restretching aluminium conductor including GI wire on existing over head lines in position without dismantling including unbinding from insulator and rebinding to insulator using aluminium binding wire, connections of incoming and outgoing cables, binding with spacers where required and trimming the tree branches with clearance of 3 mtr around of the LT OH line, complete all as specified Note :- For measurement length of each conductor shall be taken separately, however GI wire shall be included with conductor length.
M&L for painting black and white strips 05 Nos (each strips of 30 cm height) with synthetic enamel paint of black and white colour round the PCC/steel tubular pole alternatevely from the bottom of the pole including numbering of pole with black paint in Yellow background complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of loop-in/loop-out box of outer minimum size 300x200x120mm mdae out of FRP body (hot mulded type) with IP-66 protection and locking with screws comprising of aluminum bus bar rating 100 Amp, 4 strips for 3 phase and neutral along with 6 Amp rating MCB SP-01 No and duly fixed with 25x3mm FI clamps with nut bolts of suitable size on steel tubular pole/PCC/RCC pole including cable glands, aluminum lugs/thimbles for incoming and outgoing cables and embossing/painting of danger notice board of size not less than 10cmx7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of box body comple all as specified.
Trimming and cutting of tree branches coming across LT over head line, clearing alround 3m the LT line and disposal of branches/bushes to a distance upto 50m and cleaning the site complete all as directed. Note :- (i) Length of span shall be 40 to 45m (Approximately). (ii) Due care shall be given while trimming/cutting the tree branches that there shall be no damage to over head line conductor/pole. In case, due to any negligence, damage is caused, it shall be made good by the contractor and nothing extra shall be admissible.(iii) Proper shut down will be taken from department (iv) T&P will be provoded by conractor without any extra cost.
Taking out from trenches or wall / pole or pipe cable LT 1100 volts grade heavy duty, armoured with steel strip of wire, with stranded aluminium conductor of any size upto 25 Sqqmm, any core, for rectification of faults or replacement. Seggregating serviceable cable and unserviceable length by meggering or any other suitable and recommended method. Removing unserviceable cable from site and keeping aside serviceable for reuse at same laocation or any other location under AGE E/M all as required at site or directed (Earth work will be measured and paid separately under respective item)
All as per srl item 57.00 here in above but of size 35 Sqmm to 95 Sqmm
All as per srl item 57.00 here in above but of size 120 Sqmm to 185 Sqmm
All as per srl item 57.00 here in above but of size 240 Sqmm to 400 Sqmm
Laying only in trenches or fixed to wall/pole or passing through pipe cable LT 1100 volts grade heavy duty, armoured with aluminium conductor of any size upto 25 Sqmm any core (Serviceable cables retrieved against srl item 57.00 above will be used)
All as per Srl item 61.00 here in above but of size 35 Sqmm to 95 Sqmm (Serviceable cables retrieved against srl item 58.00 above will be used)
All as per Srl item 61.00 here in above but of size 120 Sqmm to 185Sqmm (Serviceable cables retrieved against srl item 59.00 above will be used)
All as per Srl item 61.00 here in above but of size 240 Sqmm to 400 Sqmm (Serviceable cables retrieved against srl item 60.00 above will be used)
Supply and errecting in replacement of Prestressed concrete pole, 9.0 metre long, 102mm x 152mm at top and 102mm x 289mm at bottom, class 10 including painting alternative black & white strips of 30 cm width upto 1.5 mtr above ground level and including dismantling and taking out the damaged/old PCC pole and setting aside within 50 mtr distance and opening the street light bracket/crossarms with connected items and street light fitting from old pole and refixing the same on new pole for street light fitting and all as required at site or directed by Engr-in-charge.
S&F in replacement of GI stay assembly set comprising of 14mm dia 400mm iron stay bow and16mm dia, 2150mm long stay rod stay plate 230x230x6mm thick, GI stay wire 7/8 SWG of required length complete with all accessories as shown in electric plate No 1 of SSR Part 1 2009 complete with excavation earth work including PCC 1:3:6 of required quantity with loop insulator, clamps nut bolts etc complete all as required and directed.
Material and labour plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in base of the pole as a foundation or in any situation all as specified and directed.
Material and labour plain cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of the pole by demolition of existing /broken coping with taking out the LT cables and GI pipe Etc and refixing in new coping or in any situation all as specified and directed.
Excavation in trenches in soft/ loose soil n.exc 1.5mtr wide and not exc 1.5mtr in depth and getting out complete all as specified and directed.
All as per item No 69.00 here in before but exc 1.5 mtr or part there of in depth beyond the first 1.5 mtr depth complete all as specified and directed by Engineer-in-Charge..
Material and labour for Sand cushioning/ Sand covering using Tibba sand for underground cable protection complete all as specified and directed by Engineer-in-Charge. Note :- For the purpose of payment, only punned thickness witch comes out 18 cm will be measured.
Supply and laying reinforced precast concrete cable cover, class LV, Type 1, flat, size 250mmx150mmx40mm laid perpendicular to cable length in trench air gap should not more than 5mm to each other after sand cushioning to cable and all as specified and directed.
Returning, filling, in including spreading, leveling , watering and well ramming in layers n.exc 25 cm in soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtrs above the starting point complete all as specified and directed by Engineer-in-Charge.
Taking out steel tubular pole (Approx 15 mtr height) and shifting and installation /erection to new location within 50 mtr distance complete with excavation earth work including PCC 1:3:6 type C-2 using 40mm graded stone aggregate for foundation and PCC 1:2:4 type B-1 using 20mm graded stote aggregate for coping and taking out 04 Nos street light and disconnecting the incoming cable with connected items and refixing the same on existing tubular pole after shifting and all as required at site or directed by Engr-in-Charge. Note: (i) The cost for earth work and PCC work is deemed to be included in above quoted rates. (ii) The steel Tubular pole to be shifted with proper safety using crane/T&P/man power as required and the cost of same is deemed to be incl in quoted rates.
Taking out old and unserviceable sign boards, including supports and supplying and fixing single shaded reflective sign board of high intensity reflective wheet computer cut background of sky blue/green colour and white letters both side (letters and diagrams to be written on the board, shall be provided by JE E/M/Engr-in-Charge) mounted on hardened aluminum alloy sheet, 2mm thick fixed on angle iron frame of suitable size and supported by MS square tubes size of 50x50 mm grouted in PCC 1:3:6 and MS square tube not less than 60cm below ground level complete all as specified. Note: (i) The charges for 50mm x 50mm square tube, 2mm thick angle iron frame, aluminum alloy sheet, PCC work, nuts and washers is deemed to be included in above quoted rates. (ii) The size of sign board should not be less than 4'x3'and height of sign board from ground level to bottom of board should not be less than 120cm
INDO CONSTRUCTION
SARASWATI ELECTRIC STORE
Shri Electrical Enterprises
Anil Builders
M/s Vishaka Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .