The Superintending Engineer
AB 9/303, IIT Gandhinagar
Replacement of Split Air Conditioners at various location at IIT Gandhinagar Campus.
2023_IITGN_784187_1
36/IITGN/IWD/2023-24
Open Tender
Electrical Works
Item Rate
90 days
IIT Gandhinagar
As per tender document
2 documents required · 2 mandatory
₹500
Payable To IIT Gandhinagar Revenue account
₹46,025
IIT Gandhinagar
4 Nov 2024
6 Dec 2023
1 Jan 2024
6 Dec 2023
30 Dec 2023
7 Dec 2023
7 Dec 2023 - 13 Dec 2023
13 Dec 2023
Amount
Supply,Installation, testing and commissioning of minimum 1.0 TR capacity split type A.C. unit, invertor type with 5 star rating, fiber body indoor unit including installation of condenser unit, installation of evaporator [cooling] unit, making suitable opening in the wall for drawing of refrigerant pipes if required, power supplying to indoor and outdoor units, wrapping the refrigerant pipes with foam / polyurithene insulation, pressure testing in the pipe lines with dry nitrogen gas as and when required, repairing of any leakage in the pipe line etc.for Ground Floor & First Floor of Old Dining Hall Manager Cabin complete as required. (Note: Rate includes laying of copper refrigerant pipe and foam insulation upto 3 metre length) (Make: Mitsubishi/Toshiba/O General/Carrier)
Supply,Installation, testing and commissioning of minimum 1.5 TR capacitysplit type A.C. unit, invertor type with 5 star rating, fiber body indoor unit including installation of condenser unit, installation of evaporator [cooling] unit, making suitable opening in the wall for drawing of refrigerant pipes if required, power supplying to indoor and outdoor units, wrapping the refrigerant pipes with foam / polyurithene insulation, pressure testing in the pipe lines with dry nitrogen gas as and when required, repairing of any leakage in the pipe line etc. complete as required. (Note: Rate includes laying of copper refrigerant pipe and foam insulation upto 3 metre length) (Make: Mitsubishi/Toshiba/O General/Carrier)
Supply,Installation, testing and commissioning of minimum 2.0 TR capacity split type A.C. unit, invertor type with 5 star rating, fiber body indoor unit including installation of condenser unit, installation of evaporator [cooling] unit, making suitable opening in the wall for drawing of refrigerant pipes if required, power supplying to indoor and outdoor units, wrapping the refrigerant pipes with foam / polyurithene insulation, pressure testing in the pipe lines with dry nitrogen gas as and when required, repairing of any leakage in the pipe line etc. complete as required. (Note: Rate includes laying of copper refrigerant pipe and foam insulation upto 3 metre length) (Make: Mitsubishi/Toshiba/O General/Carrier)
Supply, installation, testing and commissioning of 1.2 TR wall mounted high performance split type cooling units suitable for Critical Technology/Equipment room. Each unit shall facilitate installation in Small Areas, shall feature robust design to run 24x7, Auto-Restart function, Monitoring with Unit-to-Unit Communication and Ease of service.Unit comprising of two parts; Indoor section & outdoor section. The Indoor unit shall comprise of Metallic Body construction with insulated side panels, Evaporator Coil with Hydrophilic Coating, Backward Curve fan with EC motor, HDPE Washable Filters, Expansion Valve, R407C/R410a Refrigerant, Corded Remote, Microprocessor Controller, G4 Filter, Suction and Discharge piping, Internal power and Control wiring, HP/LP Cutouts, Power and Control contactors and Other Electrical & safety accessories. Outdoor cabinet consists of Compressor, Fan with single phase motor and Condenser coil. Unit must have feature for unit control, synchronising the Multiple No. of units to work as single system for all above units.Fault Failure changeover, Cascading Effect, Sequencing of above Units complete as required. (Make: Vertiv, Model No. SRC04)
Supplying and laying of additional copper refrigerant pipe line [ suction and discharge both] including providing foam / polyurithene insulation on both the refrigerant pipes separately along with necessary brazing, leak testing, etc. as required.
Supplying and laying of ISI marked CPVC pipe of 1 inch dia for draining of sweated water from AC evaporator unit including providing tee, joints, elbows wherever necessary etc. complete as required.
Supplying and laying of ISI marked pvc insulated flexible copper cable of size 3 x 2.5 sqmm of 1.1 kv grade including making connection etc. as directed by the Engineer-in-charge. [cable joint is not permissible] (Make: Havells/Polycab/Finolex)
Supplying and charging of eco friendly green refrigerant as applicable for AC unit for topping up etc. as required.
Supplying and fixing of adjustable readymade stand for resting condenser unit either on flat surface or on wall [as per site requirement], duly prepainted with anticorrosive paint, nuts, bolts, grouting / properly securing from accidental fall, etc. complete as required.
De-installation of split type air-conditioner [1.0 / 1.5 / 2 TR capacity) from its existing place, including deinstallation of indoor and outdoor unit, removing of existing refrigerant pipes, darain line etc. and shifting the indoor and out door unit to research park store room complete as required.
FORAM HVAC ENGINEERS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .