Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-AOC KATTUPADATH H AZHEEKAL PO VYPEEN 682508 | KOCHI | ERNAKULAM | KERALA | 682508 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹38.0 L+₹91,074 (2.46%)Rejected-Finance PSRA 146 A PULIMOOTTIL ROAD PADAMUGAL INDRA JUNCTION KAKKANAD PO KOCHI 682030 | KOCHI | ERNAKULAM | KERALA | 682030 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹38.0 L+₹98,187.50 (2.65%)Rejected-Finance C 111 STATION PLAZA STATION ROAD STATION ROAD BHANDUP W MUMBAI 400078 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹38.3 L+₹1.3 L (3.46%)Rejected-Finance KURUPPAMPARAMBIL PERUMPADAPPU PALLURURHY P O ERNAKULAM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹40.0 L+₹2.9 L (7.90%)Rejected-Finance | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹85,000
Closing Date
15 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI DC SHARMA
CWE (NW) KOCHI
CERTAIN SANCTION WORKS AT KATARIBAGH AND NAVAL BASE, KOCHI
2022_MES_556901_1
CWE(NW)/KOCHI/81312
Open Tender
Civil Works
Item Rate
180 days
KOCHI
AS PER NIT
6 documents required · 6 mandatory
₹500
GE (NW) KOCHI
₹85,000
Yes
1 Dec 2022
10 Oct 2022
17 Nov 2022
10 Oct 2022
15 Nov 2022
1 Nov 2022
Amount
Dismantling of plain or corrugated steel sheeting any gauge, thickness including nanital or similar pattern roof covering complete all as specified and as directed .
Dismantling wrought iron or mild steel work of any description not otherwise provided for all complete all as specified and as directed .
Excavation in post holes (or similar holes) each n.exe 0.5 cum, getting out returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25 cm watering in soft/loose soil complete all as specified and as directed .
M & L Cement concrete in post holes foundation fillings and mass concreting PCC1:3:6 type C2 using 40mm graded stone aggregate complete all as specified and as directed.
Removing excavated material n.exc 0.5Km and depositing where directed at a level n.exc 1.5m above starting point and making good surface in soft/loose soil all as specified and as directed .
S &F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to Fe -410W (gd E-250) quality A complete all as specified and as directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet , MP tile pattern 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F for pre painted plain sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding, fixed with screws all as specified and directed.
M&L for preparation of old painted steel and iron surface of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of primer complete all as specified and as directed .
Cutting grooves in brick wall 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed .
Taking down eaves gutters and rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed .
S & F UPVC RAIN WATER GUTTER (Width=200 mm, depth = 140 mm, thickness 3mm) , with all necessary fittings, clamp, joints, end cap, corner drop, centre drop, etc joining compounds, nut, bolts or screws etc and fixing in position, at any height complete all as specified and as directed. Make: euro guard prosquare or equivalent make in list of makes
S & F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls (jointing shall be done using appropriate materials) complete all as specified and as directed .
S & F PVC (SWR) bends, any radius, 110mm bore all as specified,complete all as specified and as directed .
Demolition of cement Concrete of in ground floors and pavings not otherwise specifically provided for complete all as specified and as directed .
M&L for 40mm thick PCC type B 0 1:2:4 (using 12.5mm graded aggregate ) as in repair top surface of pavement and flooring etc. and surface finished even and smooth without using extra cement complete all as specified and as directed .
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid dry complete all as specified and as directed .
M&L for Hard core of broken gauge/trap/basalt stone of Gauge exc. 63mm but n. exc 150mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rolled / rammed to a true surface complete all as specified and as directed.
M&L Coarse aggregate for granolithic floors graded from 12.5mm to 4.75mm Spreading and levelling and ramming as specified complete all as specified and as directed .
S&F machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35grade, laid over with grey cement and pigments complete all as specified and as directed
Labour only for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, with grey cement and pigment complete all as specified and as directed .
Taking down Chowkhats or frames exc. 1.5 Sqm each but not exceeding 4.00 Sqm but with shutters (without taking off shutters from the frames) complete all as specified and as directed.
S&F Powder coated aluminium frame for door/window with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed. Note:- The quoted rate shall be deemed to be inclusive of sealing the gaps between aluminium frame and wall with silicon selant of make Dr. fixit or equivalent make
S&F powder coated aluminium door shutters,aluminium section weighing 0.55Kg/m including necessary joining cleats,glazing clips,rubber neoprene packing,handles 2 Nos in eaach door hinges,anodised aluminium snap beading screws etc complete all as specified and directed.
S&F 5.5mm thick sheet glass ordinary quality and glazing with oil putty in square exc 0.5 Sqm in each pane complete all as specified and directed.
M&L for 9mm thick prelaminated particle board on both sides with decorative choice laminations interior grade ,fixed with srews to timber frame work as panel for doors complete all as specified and directed.
S&F door stopper of brass body and tongue with hard drawn steel spring 150mm over length of cover plats complete all as specified and directed.
S&F door closer aluminium dia cast body hydraulically regulated designation No.3 universal type suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 Kg and fixed complete all as specified and directed.
Surface dressing n exc 15cm deep in soft/loose soil complete all as specified and as directed
M&L for 100mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate,in sub base complete all as specified and directed.
M&L for cement concrete B1 1:2:4 (20mm graded aggregate)50mm thick for levelling course complete all as specified and as directed.
M&L for chequered cement concrete tiles 20cmX20cmX25mm thick set,jointed and pointed in neat cement slurry in floors pre polished coloured tiles glossy finish with anti skid properties laid over and including 20mm thick screed bed in CM 1:6 complete all as specified
M&L for PCC type B 1 1:2:4 (20mm graded aggregate) as in mass concrete around the machine pressed precast concrete paver block or chamfered on edges all as specified and as directed by Engg in Charge.
S&F in repair on wall/ concealed on wall high pressure CPVC pipes SDR-13.5 & plain CPVC SDR 11 fittings including all necessary fittings, solvents of size 40 mm dia complete all as specified and directed. Make : Supreme/ Eurotech/ Astral/ SFMC
S&F in repair on wall/ concealed on wall high pressure CPVC pipes SDR-13.5 & plain CPVC SDR 11 fittings including all necessary fittings, solvents of size 25 mm dia complete all as specified and directed.
S&F in repair on wall/ concealed on wall high pressure CPVC pipes SDR-13.5 & plain CPVC SDR 11 fittings including all necessary fittings, solvents of size 20 mm dia complete all as specified and directed.
S&F of Rotational moulded polythylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position of capacity 2000 litres
S&F CPVC Ball valve of size 40 mm dia suitable for CPVC pipe incl necessary fittings complete all as specified and directed.
S&F CPVC Ball valve of size 25 mm dia suitable for CPVC pipe incl necessary fittings complete all as specified and directed.
S&F CPVC Ball valve of size 20 mm dia suitable for CPVC pipe incl necessary fittings complete all as specified and directed.
S&F float valve synthetic (PVC) of size 25 mm dia high pressure with polythene ball of size 6" dia and flynut complete all as specified and as directed.
S&F centrifugal booster pump 1 HP, 0.75 KW, pressure setting range 2.0 to 3.5 kg/cm, tank capacity 24 ltrs, rust preventive aluminium die casted motor body, fitted with hot water seal, F-class insulation, suitable for hot water application all as specified and directed.Make Make V-Guard Cat Part No. VB24-TF3A / Kirloskar Pump Model : GMC 112 or equivalent make as per list of manufactures. Note : Quoted rate shall be deemed to be inclusive of suitable fitting amd fixture as per direction by engr-in-charge.
M&L for point wiring with 1.5 Sqmm PVC insulated unsheathed with proper colour coding HRFR multistranded single core copper conductor cable in PVC cassing capping non metallic medium grade with suitable size in wall /roof except beam, colum and RCC roof including incl making good wall surfaces with existing surfaces and 1.6 mm thick MS sheet pressed terminal box (recessed) with 3 mm thick PVC laminated sheet top cover for accomading switches socket regulators etc incl 1.5 Sqmm PVC insulated copper conductor as earth continuity wire for One light point controlled by one switch complete all as specified and as directed.
Supply and Fixing switch socket combination 5 pin 5 Amps flush type complete all as specified and as directed
All as per item No. 43 above but for One 5 pin 5 Amps socket point controlled by one switch on independent board complete all as specified and as directed.
S&F switch piano flush type 5A one way complete all as specified and as directed.
S&F ceiling rose surface bakelite 65 x 50mm 3 terminals complete all as specified and as directed.
S&F Tubelight fitting 2 x10 w ,with basic all purpose surface and wall mounted LED batten with Aluminum housing & integrated electronic driver complete. including taking down old one complete all as specified and directed. Make: Make Luker Cat Part No. LT510P / Philips Cat Part No. BN 021 LED10S -6500 PSU GR S1 / Havells Cat Part No. LUMILINEPLUSBS10WLED865SPCSS or equivalent”
S&F SPN sheet metal enclosure for DB 4 ways Double door complete all as specified and as directed.
S&F MCB 'B' Curve 6-32 Amp SPN, 240 Volts Make L&T Cat Part No. BB20320B / Schneider Cat Part No. A9N1P06B to A9N1P32B / Legrand Cat Part No. 4086 09 to 4086 17 or equivalent in list of makes all as specified and directed.
S&F MCB 'B' Curve SP 6 to 32 Amp, 240 Volts,Make L&T Cat Part No. BB10060B to BB10320B / Schneider Cat Part No. A9N1P06B to A9N1P32B / Legrand Cat Part No. 408587-408596 in list of makes all as specified and directed.
S&F wall mounted fans metallic body, 300 mm sweep, 900 rpm with fixing arrangements on wall including screws, rawal plugs etc. connetcing to the electrical system all as specified and directed. Make : Havells Cat Part No. Swing HS / Almonard Model : 300mm [12”] CABIN FAN HIGH SPEED / Usha Model : 300MM Helix Hi Speed Wall Fan WH” in list of makes all as specified and directed.
M&L in earthing complete with galvanised steel earth plate electrode 60 cm x 60cm x6 mm thick, buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meters below normal ground level, connected to GI earth lead wire 4mm dia upto length 7.5 mtr by means of bolts, nuts and washers of galvanised steel all as shown in electrical plate No. 3 connected to earthing test point complete all as specified and indicated including testing on completion including taking out old earthing complete. Note : The rate is deemed to be inclusive of the cost of complete earth work in any type of soil. PCC 1:3:6 type C-1 for chamber,RCC 1:2:4 type B1 for cover slab 50 mm thick, reinforcement 8 mm CTD bars @ 100 mm c/c both way, necessary form work, handle, charcoal dust 20mm dia GI med grade for watering and 40mm dia GI med grade earth lead protection pipes with funnel and wire mesh all complete all as specified and directed.
Supply & Fixing Electronic discharge rod of length 1.08 meter, voltage 22 KVA with all accessories complete all as specified & directed. Make : Honeywell or equivalent approved make.
M&L for laying electrostatic discharge flooring mat of thickness 2mm (minimum) in store houses including cutting to required shape and size laying as per manufactures instructions and as directed .
Taking down carefully the existing Tube Light fittings of any type and size keep it safe for refixing complete all as specified and as directed.
S&F 4 feet surface mounted batten type 18W/20W LED luminaire with emergency light output, shall be maximum 4 hours battery backup in case of power failure with Li battery, luminaire efficacy 100 lm/w with an operating voltage range from 140V-270V, initial lumen at battery mode will reduce to 35-50%, charging time approx 8-12 hours. The luminaire shall have aluminium extruded main housing. PC LED front cover. The luminaire shall have a CCT of 6500K, CRI>80. Power factor hours as per L70 B50 criteria. The luminaire shall be EMI/ EMC complaint and shall have open and short circuit protection, reverse polarity protection, internal surge protection of 30 KV IP 20 ingress protection. Make : Halonix Model No. HLB-08-20-CW-INV or Shakti Cat Part No. SZSLBMX018 or equivalent in list of manufactures. Note (a) LED Chip make shall be Nichia, Osram, Cree, Lumilid, Seoul semiconductor. (b) The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABl approved lab of LED Chip used and luminaire respectively while getting sample and material approved. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (d) The contractor shall submit warranty certificate from manufacturer for minimum 02 years.
Re-fixing of tube light fittings obtained at any location as directed by Engr-in-charge and connecting to the Electric system all as specified.
M/s Antony Kallarakkal
shine industries
Albert Rebello and Company
M/s ANTONY THOMAS AND CO
Classic Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .