RequiredExperience with Government
RequiredAnnual Turnover
RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate Bid to RA enabled No Tractor Trailer Mounted Suction Cum Jetting Machine ( 1 pieces ) ( Under PAC ) Make uneed Model uneedussm-3000 Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Certification Trailer confirming to IS 8213:2000 (latest) and Yes * 1/8 AIS 112 (latest) Conforming to IS:13496 for Suction Machine for cleaning Sewers
RequiredManholes and ancillary structures provided on sewer line and closed storm water drains Yes * Conforming to IS:11387 for high pressure jetting machine for sewer cleaning Yes * Necessary clearance from RTO to be obtain before supply of Trailer mounted Suction cum Jetting Machine Yes * Form 22 A - For compliance with pollution standards
Requiredsafety standards of components and road worthiness as per CMVR Rules Yes * Availability of test reports for all critical components from the manufacturer or OEM of Jetting Pumps
Requiredvacuum pumps
Requiredpower takeoff unit
RequiredJetting Hose etc shall be from any ILAC/NABL accredited/Central Govt Lab To be furnished to buyers on demand Yes * Avaliability of Test report fron approved Laboratory to prove conforming to specification as per AIS 112 for trailers to be furnished to buyer on demand Yes * Generic Parameters Type of Trailer mounted machines Suction cum jetting * GVW of Trailer 5500 More than 5500.0 Or higher Wheel base 2650 More than 2650.0 Or higher Payload capacity of 10000 More than 10000.0 Or 2/8 trailer higher Make and Model of Vacuum Pump KSB * Make and Model of Jetting Pump ksb * Make and Model of Jetting Hose uneed * Make and Model of PTO uneed * Make and Model of Hydraulic Motor uneed * Make and Model of Hydraulic Pump uneed * Make and Model of Suction Hose uneed * Make and Model of Jetting Nose uneed * Mount Type Tractor Trailer mounted * Constructional Parameters Capacity of split shaft PTO (Kgm) 280 More than 280.0 Or higher Overall Length 4652 4652.0 Overall Width 1880 1880.0 Equipment Length 1490 1490.0 Equipment Height 1260 1260.0 Equipment Rear Over Hang No No If Yes
RequiredDeclare Equipment Rear Over Hang 0 0.0 Derrick Arm Available No No Vacuum Pump - Rotary Vane/Sliding Vane Yes * Vacuum Pump Flow (Cu-m/hr) 319 More than 319.0 Or higher Vacuum Pump Power 140 More than 140.0 Or higher Rated RPM at Max Vacuum Pump Power 167 * Vacuum Relief Valve Size 6 * Vacuum Suction Depth (as per IS:13496 latest) 9 More than 9.0 Or higher Suction Hose - Lightweight
Requiredheavy Yes * 3/8 duty
Requiredreinforced
RequiredPVC along with quick connect coupling arrangement Suction Hose Internal Diameter (as per IS:13946 latest) 90 90.0 Suction Hose Length 5 More than 5.0 Or higher Number of Suction Hose (Nos) 5 More than 5.0 Or higher Safety Equipments Provide * Silencer/Filter(Micro Strainer) Yes * Exhaust Silencer and injection cooling air Inlet Silencer/Filter Yes * Blower Outlet and Air- Exhaust Silencer Yes * Check valve Yes * Vacuum Limitation Valve Yes * Drain Off valve Yes * High Pressure Jetting Pump With pressure regulating Arrangement Yes * Jetting Pump - Triplex plunger reciprocating pump Yes * Working Pressure Range of Jetting Pump 200 200.0 - 220.0 Or higher Water Flow for Pump of Jetting Machine (LPM) 220 More than 220.0 Or higher Pressure Relief Valve Size 80 * Jetting hose inner Diameter (Capable of withstanding one point five times the maximum pressure generated by the pump) 22 22.0 Jetting Hose Length 80 80.0 Number of Nozzles for 1 * 4/8 removing Blockage (Conical Head) Number of Nozzles for Flushing Sewer lines( Round Head) 1 * Number of balanced Nozzles for dry silt 1 * Total Tank Capacity (sludge tank+water tank) 3000 3000.0 - 8000.0 Or higher Water storage Tank Capacity 500 More than 500.0 Or higher Sludge Storage Tank capacity 2500 More than 2500.0 Or higher Maximum working pressure of Jetting Hose 160 More than 160.0 Or higher Minimum Burst pressure of Jetting Hose 440 More than 440.0 Or higher Thickness of tank plate (It shall be designed at a safety factor of 4 times the operating pressure)as per IS 13496 3 More than 3.0 Or higher Material of tank Mild Steel (Grade-A) Confirming to IS 2062 latest * Surface preparation and finish of tank's Exterior - sanded prior to spray painting and spray painted with two coats of superior quality anti corrosive primer and two coats of enamel metal paint Yes * Surface preparation and finish of Tank's Interior - clean water two coats anti corrosive primer & two coats of grey enamel paint & Sludge shall be with two coats of epoxy paint to resist corrosion Yes * Provision for locking and unlocking arrangement of rear Yes * 5/8 gate of tank
Requiredto be operated hydraulically for quick tipping and cleaning Hose Reel Drive operated by hydraulic motor Yes * Dished Head Yes * Tank Rear Door Opening by hydraulic system Yes * Reinforcement rings in pipes Yes * Hydraulic Pump Type Gear Type * Water Level Indicator Type (with safety coverage) Transparent Pipe * Water Level Indicator Nos 2 * Thickness of Cover for Engine
RequiredPump and Hose Reel compartment 4 More than 4.0 Or higher Material of Cover for Engine
RequiredPump and Hose Reel compartment MS Sheet MS Sheet Full bore Quick Acting Valves in the sewage path Yes * Air Pumps to safeguard the pump from overloading Yes * Make and Model of Air Pump Uneed * Sludge Trap between the Air Pump and the Tank Yes * Float cut out valve to seal the pump suction line Yes * Lubricating system for reducing friction loss Yes * Three sewer cleaning nozzles with varying rearward angles Yes * One nozzle extension for easy fixing of the Yes * 6/8 hose and the nozzle Two stop tank strainer elements Yes * Two sets of operation and service manuals and spare parts lists Yes * Hose guide Yes * Counter Yes * Performance Parameters Warranty Time 24 More than 24.0 Or higher Warranty Distance 10000 More than 10000.0 Or higher No of Free Service (with consumable) 6 * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.