| 1 | L-1₹11.5 LAccepted-AOC | L-1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L-2₹12.6 L+₹80,535.40 (6.82%)Rejected-Finance CANTT ROAD KASHNI BIN PITHORAGARH UTTARAKHAND 262520 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262520 | L-2 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
₹14.4 L
EMD Value
₹28,800
Closing Date
1 Jul 2020, 6:00 pmClosed
Garrison Engineer, Air Force, Bareilly
Garrison Engineer, Air Force, Bareilly, 243002
SPECIAL REPAIR TO LT SOLAR WATER HEATING SYSTEM, SPECIAL REPAIR TO INTERNAL WIRING FOR BUILDING NO. P/59, P/60 AND SPECIAL REPAIR TO LT PANEL INCLUDING RELATED WORKS AT AF STATION BHOWALI.
2020_MES_335368_2
8516 / E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bhowali
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer, Air Force
₹28,800
Yes
4 Aug 2020
12 Jun 2020
3 Jul 2020
12 Jun 2020
1 Jul 2020
19 Jun 2020
12 Jun 2020 - 19 Jun 2020
Amount
S & F as in repairs cylindrical type hot water stainless steel tank having 1.60 mm wall thick with and including insulation waork with 55 mm thick PUF of 40 Kg per Cum density duly covered with SS 304 powder coated 1 mm thick aluminium sheet cladding alongwith necessary staging work complete all as specified and directed for the following capacity solar water heating system of MAKE- TATA Solar, V-Guard, Solchrome, BHEL.
(a) Solar Water Heater of 500 LPD capacity.
(b) Solar Water Heater of 300 LPD capacity.
(c) Solar Water Heater of 200 LPD capacity.
(d) Solar Water Heater of 100 LPD capacity.
M & L for gas welding work for flat plate collectors of capacity 100 Litres each complete all as specified and directed.
M & L for plumbing work for solar water heater of any capacity with and including necessary GI fittings, Brass valve and the like as required at site complete all as specified and directed.
Dismantling of post or strut embedded in concrete (wood, steel or RCC), any section including taking out embedded portion and making good the disturbed ground complete all as specified and directed.
Dismantling of expanded metal any thickness or mesh fixed steel or wood fillets if any, weight not exc. 4.00 Kg per Sqm complete all as specified and directed.
M & L for providing plain cement concrete, type B-2, 1:2:4 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
S & F of mild steel work in hand rail, half round or other stock section or core for fixing of wooden hand rails, bluster, running bars, nosing of steps, wind ties, post and struts for fencing, flat iron fillets and the like including necessary cutting, drilling holes, notching etc. as required conforming to Fe-290 Grade E-165 complete all as specified and directed.
S & F of mild steel screw bolt (machine made) with hexagonal or square head at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt not exc. 5 cm and diameter of the neck of bolt exc. 5 cm but not exc. 10 cm complete all as specified and directed.
S & F of expended metal cut to length, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9 mm dia or fixing with galvanised steel staples and fixed to wood or steel members, weight per Sqm not exc. 4 Kg complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Taking down carefully aluminium / copper point wiring (light point, fan point, socket outlet point or power point) any type (batten, casing-N-caping, surface conduit or concealed conduit) complete with and including fittings and fixtures such as switches, ceiling rose, pendent, lamp holder, regulator, switch, socket outlet, shade conical etc. and making good disturbed surfaces of walls etc. as per existing finishes by plastering, repairs and distemper / white wash / colour wash etc. complete all as specified and directed.
Taking down carefully old unserviceable sub main wiring any type and description and making good disturbed surfaces of wall, roof, floor etc. as per existing finishes complete all as specified and directed.
Taking down carefully old unserviceable main switch and distribution board any type and description and making good disturbed surfaces of wall, roof, floor etc. as per existing finishes complete all as specified and directed.
Taking down carefully existing electic meters, keep the same in same custody and re-fixing the same at its original position complete all as specified and directed.
S & F of 1100 volts grade heavy duty 6.00 Sqmm size two single core PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring, drawn into & including PVC conduit medium grade not less than 20 mm dia including its all accessories & fittings, fixed concealed with and including chase cutting and making good the same as per existing specifications along with a continuous run of 4.00 Sqmm size stranded copper conductor PVC insulated (FRLS) (green colour) cable as earth wire complete all as specified and directed. NOTE: - TWO SINGLE CORE CABLES ALONG WITH EARTH WIRE AND PVC CONDUIT SHALL BE MEASURED AS ONE UNIT LENGTH.
M & L for point wiring for one light point / fan point / bell point / 5 Ampere socket outlet point (independent point), controlled by one, one way switch with 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable (FRLS) drawn into and including non-metallic regid PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed with and including necessary chase cutting on brick / stone masonry walls and making good as per existing and sunk cast iron or 1.2 mm thick pressed steel terminal boxes for mounting fittings like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded copper conductor cable (FRLS) as in earth wire and connecting all metal parts to common earth dolly complete all as specified and directed.
All as per item No. 16.00 hereinbefore but wiring for one 3 / 5 pin 5 Ampere socket outlet point on the same board, controlled with other switches complete all as specified and directed.
All as per item No. 16.00 hereinbefore but wiring for one 3 / 6 pin 15 Ampere socket outlet point on independent board and wiring using with 2.50 sqmm size cables complete all as specified and directed.
S & F of modular type switch 6 Ampere, one way, 1 Modules complete all as specified and directed.
S & F of modular type socket outlet 6 Ampere, 2 and 3 Pin combination, 2 Modules complete all as specified and directed.
S & F of modular type socket outlet 6 and 16 Ampere, 3 Pin for both rating (Total 6 Pins), 2 Modules complete all as specified and directed.
S & F of modular type switch 16 Ampere, one way, 1 Modules complete all as specified and directed.
S & F of modular type bell push 6 Ampere, one way, 1 Modules complete all as specified and directed.
S & F of environmental friendly, LED, ultra modern, energy saving, surface mounted, decorative oval shaped bulk head edge lite LED luminaire comprising high brightness LEDs of 10 watt capacity duly pre-fitted with all accessories complete all as specified and directed. MAKE- Havells, Philips
S & F of white cover plate with frame, 3 Module suitable for modular type switches complete all as specified and directed.
S & F of metal flush box 3 Module complete all as specified and directed.
S & F of white cover plate with frame, 4 Module suitable for modular type switches complete all as specified and directed.
S & F of metal flush box 4 Module complete all as specified and directed.
S & F of white cover plate with frame, 6 Module suitable for modular type switches complete all as specified and directed.
S & F of metal flush box 6 Module complete all as specified and directed.
S & F of white cover plate with frame, 2 Module suitable for modular type switches complete all as specified and directed.
S & F of metal flush box 1 or 2 Module complete all as specified and directed.
S & F of white cover plate with frame, 1 Module suitable for modular type switches complete all as specified and directed.
Supply and fixing of single phase 'DING-DONG' electric call bell, AC 230 volts complete all as specified and directed.
S & F of ceiling rose surface bakelite, 65 X 50 mm, three terminals, PVC / polycarbonate insulated body complete all as specified and directed.
S & F of wall / surface mounted type LED light fitting 1 X 20 watt (4 feet long), as per Cat. Part No. LUMILINE BS20WLED 865SPCWH of Havells or BN021C LED20S PSU CDL GRBN021C LED20S PSU CW GR S2 (SmartBright) of Philips complete with all accessories internally pre-wired and including making electric connection with flexible twin core 1.00 sqmm size stranded copper conductor cable from light fitting to ceiling rose complete all as specified and directed.
S & F of lamp holder, PVC / polycarbonate type insulated body with back plate suitable for batten / angle fittings complete all as specified and directed.
S & F of fan regulator, rotary step type, 120 / 280 watt, polycarbonate body complete all as specified and directed.
S & F of flush mounting factory made Ekinoxe TPN DB's Double door, 415 volts, 4 way (Cat. Part No. 607715 of Legrand or having same specifications in L&T / SCHNEIDER / C&S), IP-43 Protection, IK-09 with metal door, with neutral bar, Earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed.
S & F of isolator, 04 pole, 63 Ampere breaking capacity 10 KA, 240 volts complete all as specified and directed.
S & F of flush mounting factory made Ekinoxe SPN DB's Double door, 8 way (Cat. Part No. 607711 of Legrand or Cat. Part No. A9HSND08 of SCHNEIDER or Cat. Part No. CSDBSPNDD08 of C&S), IP-43 Protection, IK-09 with metal door, with neutral bar, Earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed.
S & F of isolator, douple pole, 32 Ampere breaking capacity 10 KA, 230 volts complete all as specified and directed.
S & F of MCB single pole 230 volts, 6 to 32 Ampere 50 Hz, 10 KA, ‘C’ series complete all as specified and directed.
M & L for earthing complete with galvanised steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.50 m below normal ground level, connected to galvanised earth lead 4 mm dia all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel TMT bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:2:4 type B-1, GI protection pipe light grade 15 mm bore including testing on completion of job complete all as specified and directed. NOTE: - ON TESTING AFTER COMPLETION OF JOB, IF DESIRED EARTH RESISTANCE (i.e. LESS THAN ONE OHM) IS NOT OBTAINED, THE EARTHING SHALL BE REDONE BY THE CONTRACTOR WITHOUT ANY EXTRA COST TO GOVT.
Supply and laying in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade, ISI marked, 16 Sqmm 4 core, LT cable (heavy duty), XLPE insulated served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed with stranded aluminium conductor cable including commissioning and testing with and including taking down old unserviceable one complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for laying cables or the like and getting out in any type of soil including trimming sides and forming bottom surface to the required level / slope etc complete all as specified and directed.
M & L for laying of course sand free from sharp materials as in filling in trenches for cable protection, laid to a uniform thickness of 23 cm (15 cm under the cable and 8 cm over the cable) and gently punned down to 18 cm thickness as required complete all as specified and directed.
M & L for laying brick as in protection covers over cables using well brunt sub class 'B' old size bricks in trenches over sand cushioning complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm in each layer as in soil complete all as specified and directed.
Removing excavated material (soil) to a distance exc. 50 m but not exc. 500 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
Taking down carefully existing MCCB in type and capacity complete all as specified and directed.
Supply and fixing of MCCB 200 Ampere capacity, 4 Pole, 50 Hz, 415 Volts with rupturing capacity of 25 KA having overload and short circuit protection ON/OFF indictor with thermal setting between 70% to 100% complete all as specified and directed.
Supply and fixing of MCCB 160 Ampere capacity, 4 Pole, 50 Hz, 415 Volts with rupturing capacity of 25 KA having overload and short circuit protection ON/OFF indictor with thermal setting between 70% to 100% complete all as specified and directed.
Supply and fixing of MCCB 100 Ampere capacity, 4 Pole, 50 Hz, 415 Volts with rupturing capacity of 25 KA having overload and short circuit protection ON/OFF indictor with thermal setting between 70% to 100% complete all as specified and directed.
Taking down old unserviceable LT panel alongwith all accessories and Supply, installation, testing and commissioning of new factory made LT distribution panel board, outdoor type, cubical shaped of size 1200 X 1200 X 450 mm, floor mounted, made of 3.15 mm thick mild steel sheet suitably spaced in totally enclosed chamber, duly mounted on 40 X 40 X 4 mm angle iron frame suitable for 3 phase, 4 wire system, having aluminum LT bus bar of 600 Amperes for phases and neutral, install on porcelain / epoxy insulator. The panel shall be dust proof, vermin proof (IP-54) and painted both sides with two coats of syntheitc enameled paint over a coat of red oxide primer and provision of complete internal wiring with PVC insulated copper conductor multi-stranded cable 1100 Volts grade IS-694 marked of appropriate gauge including all copper lugs complete all as specified and directed comprising of the following accessories in housed in panel box:-
M & L for earthing complete with galvanised steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.50 m below normal ground level, connected to galvanised earth strip of size 32 X 6 mm by means of GI nut-bolts, washer and check nuts etc., all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel TMT bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:2:4 type B-1, GI protection pipe light grade 40 mm bore including testing on completion of job complete all as specified and directed. NOTE: - ON TESTING AFTER COMPLETION OF JOB, IF DESIRED EARTH RESISTANCE (i.e. LESS THAN ONE OHM) IS NOT OBTAINED, THE EARTHING SHALL BE REDONE BY THE CONTRACTOR WITHOUT ANY EXTRA COST TO GOVT.
S & F of junction box of size 300 X 300 X 200 mm made of 2.0 mm thick mild steel sheet duly painted with two coats of synthetic enamel paint over a coat of red oxide primer having water proof front openable hinged door, with two holes in the bottom side of box for cable entry including one No. 63 Ampere capacity 02 pole MCB, mild steel clamp made of 40 X 5 mm flat iron and nut-bolts etc. as required for mounting of connection box on electric pole with and including taking down old unserviceable one complete all as specified and directed.
Supply and laying in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade, ISI marked, 50 Sqmm 3.5 core, LT cable (heavy duty), XLPE insulated served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed with stranded aluminium conductor cable including commissioning and testing with and including taking down old unserviceable one complete all as specified and directed.
Supply and laying in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade, ISI marked, 25 Sqmm 3.5 core, LT cable (heavy duty), XLPE insulated served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed with stranded aluminium conductor cable including commissioning and testing with and including taking down old unserviceable one complete all as specified and directed.
m/s vishnu kumar agarwal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .