EEEANDMWSCN/M-5
EEEANDMWSCN/M-5 NEAR KANHIYA NAGAR METRO STATION DELHI-35
Augmentation of water supply by replaceing the old worn out EANDM equipments from Bulbird road BPS under AE-V sub divison.
2022_DJB_214322_4
NIT NO. 17 (2021-2022)
Open Tender
Miscellaneous Services
Item Wise
30 days
EEEANDMWSCN/M-5
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
THROUGH DJB OFFICIAL WEBSITE IN LINK TENDER
₹9,200
24 Jan 2022
6 Jan 2022
14 Jan 2022
6 Jan 2022
14 Jan 2022
6 Jan 2022
Dismantling the existing complete Electrical & Mechanical connections from Supply meter/ Main Switch/Change Over/Starter /Motor and Old Monoset with dismantling of Monoset from Base.Removing suction and delivery lines, Sluice Valve, NRV etc as per instruction of Engineer In Charge by electric cutter, tool & Tackle, manual labour and shifting the same to JE Store as per Engineer In Charge,where required including Cartrage. Incomer Switch Fuse Unit disconnecting the Incoming / outgoing cables etc. Dismantling the switchgear in the complete shut down and safe conditions as per the availability of shut down at site.
Providing/Fixing of 415 Volt, 50 Hz, Three Phase, Rated Capacity 10 HP Centrifugal Monoset Pumps for Clear Water Supply with TEFC Induction Motor F Class Insulation, Heavy duty for site. Having specification:- 1. Power -7.5 KW 2. Moter Current- 15.0 Amps. 3. Speed – 2850 RPM (Min.) 4. Pump Size (Inlet * Outlet) – 100x80 mm 5. Head Range – 24-33 Meters 6. Discharge Range – 1400 – 700 LPM Make- Kirloskar/Crompton Greaves/Beacon/DJB Approved Including Providing/Fixing of MS Base Frame for Monoblock Pumpset including MS foundation bolt as per Sample and site requirements And including 16 Mtrs. 06 Sq.mm Three Core Copper Conductor Cable of DJB approved make
Providing/Fixing of CIDF non rising spindle sluice valve, PN 1.0, IS: 14846 size 80mm. Make: - Kirloskar/IVC/DJB Approved
Providing/Fixing of CIDF swing type Non return valve as per IS 5312 (Part 1&2), PN1.0, size 80 mm. Make: - Kirloskar/IVC/DJB Approved
Providing/Fixing of nut bolt with washers of good quality
Providing/Fixing of Rubber insertion sheet 50% synthetic.. Make: Jyoti/DJB Approved
Providing/Fixingof MS pipe 100 mm dia, ‘C’ class as per IS: 1239, Make:-Jindal/Tata/DJB Approved
Providing/Fixing of MS pipe 80 mm dia, ‘C’ class as per IS: 1239.Make:-Jindal/Tata/DJB Approved
Providing/Fixing of MS flange of 80mm. ISI Mark. (Heavy Duty)
Providing/Fixing of MS flange of 100mm. ISI Mark. (Heavy Duty)
Providing/Fabricating of MS Bend of size 100MM ISI Mark. (Heavy Duty)
Providing/Fabricating of MS Bend of size 80MM ISI Mark. (Heavy Duty)
Providing/Fixing of CI foot Valve 100 MM, Make : Kirloskar/IVC/DJB Approved Make
Installation of Complete Charging System with civil work for fiiting of charging set to storage tank with required elbow union & Socket 25/20/15 mm dia as per site requirement and the 100 Ltrs. Capacity Storage Tank Make-Sintex/and testing on full load complete at site.
Providing /Fixing of Pressure Gauge of 150 mm dia Size Having 0-100 Range with accessories such as GI fittings, Gate Valve, Bib cock etc required to complete the work. Make:- H Guru/Fibeg/DJB Approved
Painting all pipes, Valves, MS Frame, accessories etc with two coats of black enamel paint at site.
Providing /Fixing of Water level indicator of Electrical type suitable for 10 Points/10 Ft. (Min.) Water level Sensor wire should be 8 Mtrs(Min.) IS and all accessories required as per site requirements Make:- DJB Approved
Providing / Fixing 01 No. Ceiling Fan of 1200 mm swing Make- Crompton/Hawells/Bajaj/DJB Approved
S/O LT Distribution panel sheet steel enclosure made out of MS Sheet 16/18 SWG totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets to provide IP-54 protection .The each part of the fabricated panel will be strictly subjected to seven tank treatment. The various components, assemblies and sub equipment of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized in aluminum. The control wiring of the panel will be done with PVC flexible copper wires of 1.5 Sqmm & 2.5 sqmm cross section. Each wire will be terminating with a ferule crimped to the wire Duly Painted with Red Oxide Paint thereafter light grey Color and sign of denger on panel panel size- 900x1200x300mm pedestal type ,angal size-40x40x5mm panel with following material . Including supply of following Electrical/Electronics Equipments:- A 100A FP MCCB 25 KA WITH SPREDER +ROH Make-: L&T/Schnider/DJB Approved 01 Nos. B DIGITAL AMP METER 96MM WITH ASS Make-: L&T/Schnider/DJB Approved 02 Nos. C DIGITAL VOLT METER 96MM WITH VSSMake-: L&T/Schnider/DJB Approved 01 No D C.T 30/5A TAP BOUNDMake-: L&T/Schnider/DJB Approved 06 Nos. E MOTOR PROTECTION RELAY Make-: L&T/Schnider/DJB Approved 02 Nos. F CONTACTOR 32A Make-: L&T/Schnider/DJB Approved 02 Nos. G OVERLOAD RELAY 14-25A Make-: L&T/Schnider/DJB Approved 02 Nos. H INDICATOR R.Y.B , ON/OFF Make-: L&T/Schnider/DJB Approved 07 Nos. I PUSH BUTTON FOR START /STOP Make-: L&T/Schnider/DJB Approved 04 Nos. J 1NO +1NC BLOCK Make-: L&T/Schnider/DJB Approved 04 Nos. K 50A TP CONTACTOR Make-: L&T/Schnider/DJB Approved 02 Nos. L PHASE SEQUENCE RELAY Make-: L&T/Schnider/DJB Approved 01 No. M TP MCB 32A Make-: L&T/Schnider/DJB Approved 02 Nos. N CAPACITOR 5 KVAR Make-: L&T/Schnider/DJB Approved 02 Nos. O 32A TERMINAL OPEN TYPE Make-: L&T/Schnider/DJB Approved 02 Nos.
Earthing made for LT distribution Panel with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as per site requirements.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete 40 mm thick with 20 mm nominal size stone aggregate for Monoblock, LT Distribution Panel as per site requirement.
Making proper connection for all E&M equipments, with proper support as per site requirements and as per guidance of Engineer In Charge. Making the Incoming cable connections from the main supply and outgoing cable connections to the existing changeover including providing all the material as required such as main cable etc as per site requirement. Assembling, Installing, Testing and commissioning all accessories, i.e. Panel and its accessories. the installed E&M equipments for operations first at NO load and then at ON load including operation as per the satisfaction of the engineer in charge
ztp corporation
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .