Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹9.4 L+₹3.1 L (49.7%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN LOWEST BIDDER |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
11 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ CWE Rajouri PIN-900129 C/o 56 APO
REPAIR/REPLACEMENT OF UNSV PARTS OF SUMMER APPLIANCES AND CONNECTED WORKS AT RAJOURI UNDER GE 862 EWS
2022_MES_557655_1
CANO-CWE/RAJ-67/2022-23
Open Tender
Support/Maintenance Service
Item Rate
180 days
Rajouri
Class E Category c(i)
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹20,000
Yes
23 Dec 2022
14 Oct 2022
18 Nov 2022
14 Oct 2022
11 Nov 2022
28 Oct 2022
Amount
REPAIR TO REFRIGERATOR Dismantling refrigerator of any make capacity for taking out compressor/condenser/freezer unit etc. for repair/ replacement of unserviceable parts, cleaning condenser/ freezer unit of foreign particle and descaling with carbon dioxide gas to ensure smooth flow of refrigerant gas, reassembling the appliance, testing and placing in position complete all as specified and directed. Note: Repair/ replacement of unserviceable parts shall be measured & paid separately.
S&F in replacement hermetically sealed compressor unit 1/8 HP for 165/175 Ltr refrigerator, including initial gas charging after fitment complete all as specified and directed. Make:- Blue Star/Godrej/Emerson Copeland/Kirloskar/ Usha/Shree Ram.
S&F in replacement hermetically sealed unit compressor 1/6 HP for 280 to 310 Ltr refrigerators, including initial gas charging after fitment complete all as specified and directed. Make:- Blue Star/Godrej/Emerson Copeland/Kirloskar/ Usha/ Shree Ram.
S&F in replacement of PCB (printed control board) and sensor complete all as specified and directed.
Supply and filling of refrigerant gas R-134A of required quantity including detection and rectification of leakage before charging of gas into compressor including replacement of filters complete all as specified and directed.
S&F in replacement of copper capillary tube of refrigerator, any description complete all as specified. Make : ISI marked.
S&F in replacement starting relay of refrigretor any capacity complete all as specified and directed.
S&F in replacement over load protector for refrigerator, any description complete all as specified and directed.
S&F in replacement Thermostat of refrigretor of any capacity complete all as specified and directed. Make : ISI approved make.
S&F in replacement freezer compartment including door and accessories for 300 ltrs capacity refrigerator complete all as specified and directed. Make:- Godrej/LG/Whirlpool/Samsung /Kelvinator.
S&F in replacement freezer compartment including door and accessories for 165/175 ltrs capacity refrigerator complete all as specified and directed. Make:- Godrej/LG/Whirlpool/Samsung/Kelvinator.
REPAIR TO WATER COOLERS Dismantling water cooler for taking out compressor/ condenser unit etc. for repair/replacement of unserviceable parts, cleaning condenser unit of foreign particle and descaling with carbon dioxide gas to ensure smooth flow of refrigrant gas, reassembling the appliance, testing and placing in position complete all as specified and directed. Note: Repair/ replacement of unserviceable parts shall be measured & paid separately under respective items of BOQ.
S&F in replacement hermetically sealed compressor unit 1/6 HP for 80/120/150 Ltr capacity water cooler, including initial gas charging after fitment complete all as specified and directed. Make : Blue Star/Godrej/Emerson Copeland/ Kirloskar/ Usha/Shree Ram.
Supply and filling of refrigerant gas R-22 of required quantity including detection and rectification of leakage before charging of gas into compressor including replacement of filters complete all as specified and directed.
S&F in replacement of copper capillary tube of refrigerator, any description complete all as specified and directed.
S&F in replacement starting capacitor 60-80 mfd complete all as specified and directed. Make:- APCOS/HAVELLS/SEIMENS.
S&F in replacement running capacitor 15 mfd complete all as specified and directed. Make:- APCOS/HAVELLS/SEIMENS.
S&F in replacement thermostat for water cooler any description complete all as specified and directed.
S&F in replacement starting relay for water cooler any description complete all as specified and directed.
S&F in replacement push cock of stainless steel for water cooler any description complete all as specified and directed.Make:- Panko/Jainko/GEM.
REPAIR TO AC WINDOW TYPE Dismantling and taking out compressor/condenser unit/blower motor etc. from window type AC of capacity 1.5 TR and for repair/replacement of unserviceable parts, cleaning condenser unit of foreign particle, reassembling the appliance, testing and placing in position complete all as specified and directed. Note: Repair/ replacement of unserviceable parts shall be measured & paid separately.
M&L complete servicing of Window AC 1.5/2 Ton Cap.including disconnecting setting a-side cleaning dust particles with blowers and cleaning the condensor fins with chemical and finally with water, rescumbling and testing all up to the satisfication of EIC.
S&F in replacement hermetically sealed compressor unit for AC 1.5 Ton, including initial gas charging after fitment complete all as specified and directed. Make:- Hindustan/Atlas/CCI or any other ISI Make.
Taking out old unserviceable blower with fan motor from window type AC 1.5 ton capacity and providing new blower fan motor double shaft, 3 speed, single phase, AC, 1/5 HP, 920 RPM complete all as specified and directed.Make of motor :- As existing, Make of blower : As per existing.
S&F in replacement starting capacitor 100-120 mfd for AC any description complete all as specified and directed. Make : APCOS/HAVELLS/SEIMENS.
S&F in replacement starting relay SR-1622 for AC any description complete all as specified and directed.
S & F in replacement strip type heater(M type)2 KW for window type Accomplete all as specified and directed. Make:- Theata/Dasspass/Airex
S&F in replacement running capacitor 36 mfd complete all as specifiedand and directed. Make : APCOS/HAVELLS/SEIMENS
REPAIR TO AC SPLIT TYPE Dismantling and taking out compressor/condenser unit/blower motor etc. from split type AC of capacity 1.5 to 2.0 TR and for repair/replacement of unserviceable parts, cleaning condenser unit of foreign particle, reassembling the appliance, testing and placing in position complete all as specified and directed. Note: Repair/ replacement of unserviceable parts shall be measured & paid separately Undr respective item of BOQ.
M&L for complete servicing of Split AC 1.5/2 Ton Cap.including disconnecting setting a side cleaning dust particles with blowers and cleaning the condensor fins with chemical and finally with water, reassembling and testing all up to the satisfication of EIC.
S&F in replacement condensor Fan motor complete for AC 1.5 to 2.0 Ton complete all as specified and directed. Make : HINDUSTAN/ATLAS/CCI or any other ISI Make.
Rewinding with super enameled copper winding wire of standarad gauge, blower motor including replacement of ball bearing,insulating material complete for AC 1.5 to 2.0 Ton complete all as specified and directed. Make : Hindustan/Atlas/CCI.
S&F in replacement of PCB (printed control board)Dule mode and sensor complete all as specified and directed.
S&F in replacement of running capacitor (capacity 40/50 mfd) complete all as specified and directed. Make : APCOS/HAVELLS/SEIMENS
S&F in replacement hermetically sealed compressor unit for 1.5/2.0 Tonne split type AC, including initial gas charging after fitment complete all as specified and directed. Make : Blue Star/Godrej/Emerson Copeland/Kirloskar/ Usha/Shree Ram.
REPAIR TO DEEPFREEZER Dismantling of deep freezer for taking out compressor/ condenser/freezer unit of foreign particle and descaling with carbon dioxide gas to ensure smooth flow of refrigerant gas, reassembling the appliance , testing and placing in position complete all as specified and directed. Note:- Repair/replacement of unserviceable parts shall be measured and separately. Make:- kirloskar/LG/Whirlpool
Replacement of hermetically sealed compressor unit for 1/6 HP for 310 Ltr deep freezer, including initial gas charging after fitment Complete all as specified and directed. Make : Blue Star/Godrej/Emerson Copeland/Kirloskar/ Usha/Shree Ram.
Replacement of starting relay complete suitable for deep freezer Complete all as specified and directed.
Replacement of over load protector for deep freezer any description complete all as specified.
Replacement of thermostat complete all as specified and directed. Make:- Whirlpool/ Renutrol
Replacement of filter complete all as specified and directed.
Replacement of condenser fan motor complete all as specified and directed.
Replacement of remote of Split Air coditioner Make:- As per Existing
Dismantling of the window type air conditioner of capacity 1.5/2.0 TR from the existing position and shifting the same to the new altered location, make arrangement at site, stablizer and cable etc and testing complete all as specified and directed.
Repairs to industrial type RO plant of capacity 100 liters per hour of any type make by dismantling and carry out servicing and overhauling and making functional after throughly examine/checking all components, inlet and outlet piping system, descaling complete,pressure meter, auto flushing (solenoid valve), automatic ON/OFF, indicators and anti scalant dosing system etc and replacement of spare parts/components viz 100 GPD membrane, filter set, adoptor, motor, solenoid valve, and pipe coupling set and testing for its performance complete all as specified and directed. Note:- (i) 100 GPD membrane, filter set, adopter, motor, solenoid valve shall be measured and paid sepretely as supply only.
Supply only 100 GPD membrane suiltable for reserve osmosis (RO) plant of capacity 100 liters per hour complete all as specified and directed.Make:- As per RO plant.
Supply only filter set suiltable for reserve osmosis (RO) plant of capacity 100 liters per hour complete all as specified and directed.Make:- As per RO plant.
Supply only adopter suiltable for reserve osmosis (RO) plant of capacity 100 liters per hour complete all as specified and directed.Make:- As per RO plant.
Supply only solenoid suiltable for reserve osmosis (RO) plant of capacity 100 liters per hour complete all as specified and directed.Make:- As per RO plant.
S&F in replacement PVC insulated & PVC sheathed multi stranded copper conductor cable flexible 3 core, 2.5Sqmm complete all as specified. Make:- Polycab/Finolex/Anchor.
Supply and fix in replacement of sheet metal enclosures with two pin and earth plug and socket complete with single pole MCB 20 Amps complete all as specified and directed. Make:- Anchor/Havells/Indo Asian.
Supply and fix in repair MS wall bracket prefabricated, duly painted suitable for fixing of out door unit of split type Air Conditioner with necessary nuts, bolts & washers and removing old unserviceable items and making good disturbed surfaces to match with the existing complete all as specified and directed
Supply and fix in repair indoor unit of the split type air conditioner 1.5 TR capacity having 3 Star Rating complete with all accessories such as installation plate with screws, blower motor, swing motor, filters and PCB etc duly prewired and including reconnecting of existing refrigerant piping, electrical connections, drain pipe etc, and testing including removing old unserviceable items complete all as specified and directed.Make: Hitachi/Daikin/Voltas.
Dismantling of the split type air conditioner of capacity 1.5/2.0 TR from the existing position and shifting the same to the new altered location at any height,including core cutting, complete indoor and outdoor units, with new refrigerant tubing from indoor to outdoor unit, acoustic padding, MS stand, stablizer and cable etc and testing complete all as specified and directed
Supply and fix in repair outdoor unit of the split type air conditioner 1.5 TR capacity, having 3 Star Rating complete with all accessories such as hermetically sealed compressor, condenser unit, capacitors, relays, fan motor, hot and cold mode facility as per weather condition,duly prewired and including reconnecting of existing refrigerant gas piping, electrical connections, etc and testing including removing old unserviceable items complete all as specified and directed. Make: Hitachi/Daikin/Voltas.
narayan construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .