Loading…
Loading…
Tender Value
₹4.1 L
EMD Value
₹4,148
Closing Date
13 Oct 2026, 4:00 pm5d left
Deputy Executive Engineer, Electric (R&B) Sub Division, Rajkot.
Replacing Old & u/s Cubical Panel in M.G. Hostel , Pathikashram , Manoharsinhji Hostel and Other Residential Site of Section 1 to 4 at Rajkot.
351066
No.13 of 2026-27
Open
Electrical Works
Works
Rajkot
9 documents required · 8 mandatory · 1 optional
₹600
Deputy Executive Engineer, Electric (R and B) Sub Division, Rajkot.
₹4,148
1 Oct 2026
1 Oct 2026
1 Oct 2026
13 Oct 2026
1 Oct 2026
Name of work: Replacing Old & u/s Cubical Panel in M.G. Hostel , Pathikashram , Manoharsinhji Hostel and Other Residential Site of Section 1 to 4 at
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
In Figures In Word
Qty. Unit estiamted
Replacing Old & u/s by providing and erecting Mains with ISI
marked, 1.5kV grade electrolyte multi stranded, annealed
copper conductor with heat resistant PVC insulated conforms
Rupees Eight Hundred
to IS 694, IEC - 227 erected in existing pipe of following size
1 4.00 Mtr 837.29 ThirtySeven Paise
(Specifically for control panel, relays, power switchgears,
TwentyNine Only
motor starters & control wiring) with required size of copper
lugs, nuts and bolts if required.(k) One wire 70.00 sq. mm
(i) One wire 35.00 sq. mm Rupees Three Hundred
48.00 Mtr 376.73 SeventySix Paise
SeventyThree Only
(f) One wire 10.00 sq. mm Rupees One Hundred
92.00 Mtr 115.14 Fifteen Paise Fourteen
(e) One wire 6.00 sq. mm Rupees Seventy Paise
Providing and erecting Approved make Four pole moulded
case circuit breaker having breaking capacity ICU of 25 KA. at
415 V,having normal current rating up to 25 A to 100A. with Rupees Six Thousand
2 5.00 Ea Fixed thermal & magnetic release suitable to work on A.C. 6790.23 Seven Hundred Ninety
supply 50 Hz. with all internal connections, spreader tinned Paise TwentyThree Only
copper & complete erected in existing 16 G.M.S. housing.
ICS=100% of ICU only Cat III
Providing and erecting Approved make Four pole moulded
case circuit breaker having breaking capacity ICU of 35 KA. at
415 V. having normal current rating 125A. with Fixed thermal Rupees Eight Thousand
3 5.00 Ea & magnetic release suitable to work on A.C.supply 50 Hz. with 8861.74 Eight Hundred SixtyOne
all internal connections, spreader tinned copper & complete Paise SeventyFour Only
erected in existing 16 G.M.S. housing. ICS=100% of
ICU only Cat III
Providing and erecting Approved make Four pole moulded
case circuit breaker having breaking capacity ICU of 35 KA.
and above at 415 V . having normal current rating 250A. with Rupees TwentyThree
4 1.00 Ea variable thermal & magnetic release suitable to work on 23041.13 Thousand FourtyOne
A.C.supply 50 Hz. with all internal connections, spreader Paise Thirteen Only
tinned copper & complete erected in existing 16 G.M.S.
housing. ICS=100% of ICU only Cat III
Replacing Old & u/s by Supplying and erecting triple pole &
neutral 440V / 500V panel mounting Copper Busbars with four
equal Nos. of electrolyte bus having current density not more
than 1.6 Amp. / sq.mm (Rated current / cross section area) duly Rupees One Thousand
5 2.50 Rmt wrapped with colour insulating tape for phase sequence of 1961.42 Nine Hundred SixtyOne
following current carrying capacity, erected with necessary bus Paise FourtyTwo Only
bar supports /insulators, main cable socket to each bar, erected
in existing cubical panel with necessary connections.(A)
Suitable for 100 Amp. Capacity
(B) Suitable for 200 Amp. capacity Rupees Three Thousand
1.00 Rmt 3202.71 Two Hundred Two Paise
SeventyOne Only
(C) Suitable for 300 Amp. capacity Rupees Four Thousand
0.50 Rmt 4909.61 Nine Hundred Nine Paise
Replacing Old & u/s by Providing & erecting 415 V MCB
Rupees Seven Hundred
Four Pole for Motor & Inductive Load (C Curve) having
6 18.00 Ea 736.29 ThirtySix Paise
10KA breaking capacity & confirms to IS :8828 in existing box
TwentyNine Only
having following capacity (b)40 Amp. Cat.III
(c)63 Amp.Cat.III Rupees Eight Hundred
Eleven Paise Three Only
Replacing Old & u/s by Providing & erecting 240 V MCB
Rupees Three Hundred
double pole switch for lighting Load (B Curve) having 10 KA
7 79.00 Ea 325.22 TwentyFive Paise
breaking capacity & confirms to IS : 8828 in existing box
having following capacity (B) 40 Amp. Cat.III
providing and erecting Approved make RCCBs conforming to
IS: 12640 and having sensitivity of 30 mA and Short Circuit
withstand capacity of 10 KA and suitable for operation on Rupees Two Thousand
8 3.00 Ea single phase 240 V,50Hz. having characteristic of quick action 2458.34 Four Hundred FiftyEight
& tripping with all advance feature & do not incorporate any Paise ThirtyFour Only
electronic component. for following Max. rating erected as
directed (ii) 40Amps. DP Cat. III
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
In Figures In Word
Qty. Unit estiamted
Providing and erecting Approved make RCCBs conforming to
IS: 12640 and having sensitivity of 30 mA and Short Circuit
withstand capacity of 10 KA and suitable for operation on 3 Rupees Two Thousand
phase and neutral 415V,50Hz. having characteristic of quick Eight Hundred
action & tripping with all advance feature & do not incorporate TwentyFive Paise
any electronic component for following Max. rating erected as NinetyEight Only
directed. (i) 25 Amps.FP Cat. III
Providing , erecting , fabricating the M.S. structure as per
requirement on site incorporating proper size of M.S.
angles,square,round, flats, bars, channels, sections complete
Rupees SeventySeven
10 240.00 Kg with cutting, welding, grinding & finishing duly painted with 77.77
Paise SeventySeven Only
one coat of red oxide with erection on site as per direction of
engineer in charge with necessary grouting, cementing,
plastering & finishing complete.
Supplying & erecting earth pit of minimum bore dia.150mm
size approved make Earthing Electrode consisting Pipe-in-Pipe
Technology as per IS 3043-1987 made of corrosion free hot
dipped G.I.Pipes having Outer pipe dia of 50mm having 80-
200 Micron galvanising, Inner pipe dia of 25 mm having 200-
250 Micron galvanising, connection terminal dia of 12mm with
constant ohmic value surrounded by highly conductive
compound with high charge dissipation suitable for following
type of applications with chamber and heavy duty cover.
(A)(approved make OEM has to submit test certificate
including value of earth resistance of installation duly stamped
and signed by agency and officer Incharge has to ensure the
value of earthing resistane mentioned in test Certificate) &
having back filling compound of
(B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm /
meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at
no load & dry form, Sulphar content:- <2%(C) Back fill
Compound :- Earthing compound should be capable to retain Rupees Four Thousand
8.00 Ea moisture for long time Necessary test report must be submitted 4591.46 Five Hundred NinetyOne
by Agency. (a) For Electrical Installation up to 440V in normal Paise FourtySix Only
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
Replacing Old & u/s by Providing & erecting weather proof,
dust & vermin proof, floor mounted front operated indoor type
cubical panel board necessary IP-42 and above protection as
per approval from engineer incharge made from 14 SWG thick
CRC M.S. sheet for outer body & doors, 16 SWG thick CRC
M.S.sheet for internal partitions with necessary accesories
supporting angles/ flats channel including cutting, bending,
drilling, welding, riveting with internal partitions & cable alley
as per requirements & instruction of engineer-in-charge with
supplied switch gears, BUSBARS, suitable size of inter
connecting PVC copper wire / copper-aluminium strips, rubber
grommets, rib, bakelite control fuses/MCB for measuring
instruments, earth bus & earth bolts, foundation flange - bolts-
base Plates, sufficient nos. of hinged doors, handles with
locking arrangement and rubber gasket,heavy duty end
terminal connection,danger notice board,necessary
ventilation,earthing strip complete. The Panel shall be painted
with epoxy powder coating. (The rates excludes the cost of
switchgears, bus bars, inter connecting mains & Copper
Aluminium strips, meters, Fuses etc. The dimension shall be
measured excluding base beams) The panel shall be supplied
with following approved manufacturers with following size.
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
In Figures In Word
Qty. Unit estiamted
(B) The standard companies switch gear shall be used and only Rupees Fourteen
10.12 Sq.mtr manufacturers at CPRI approved factory (i) with 350mm depth 14902.55 Thousand Nine Hundred
Two Paise FiftyFive Only
Rupees Four Lakh Fourteen Thousand Seven Hundred FiftyTwo Paise FiftySix Only
Note:- The Credit of dismentalled materials for Rs.8498.00 shall be recovered from the First R.A. bill payable to the contrator and there after the
dismentalled materials shall be the property of the contractor.
I/We am/are willing to carry out the work at__________________% above/below (in figures)_____________________________________percent Above / below (in
words) the estimated rates mentioned above amount of my\our tender works out as under :-
Estimated amount put to Tender Rs. _________
Deduct________% below Rs. _________
Net Amount Rs. _________
Estimated amount put to Tender Rs. _________
Net Amount Rs. _________
A I/We hereby declare that I/we have visited the site and fully acquainted my self / our selves with the local situation regarding material,labour and
other factors pertaining to the work before submitting this tender.
B I/We hereby declare that I/we carefully studied the conditions of contract, detailed technical specifications and other tender documents of this
work and agree to execute the same accordingly.
C Any Excess in Tender Item/Extra Item if Needs to be Execute. Contractors has to carry out work on the instruction of Competant Authority on
Tender Submitted rate,No Excuse will be Accepted.Hence Contractor are Requested to quote the rate considering this condition.
D Contractor are requested to quote the Tender by considering that payment will be made after availibility of grant.Contractor has to start the work
immediately after issue of Work Order and as per instruction of Engineer-in-Charge irrespective of availibility of grant.
E "This estimate has been prepared on the new SOR wich is exclusive of GST hence GST additional will be paid to the agency as per existing
(Signature of the Contractor) Deputy Executive Engineer
Electrical R&B Sub Division
Executive Engineer
Electrical R&B Division
Note 1 Please strike out whichever is not applicable.
2 In the case of tendered amount being quoted incorrectly the quoted pered percentage Below/Above will be considered as final.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Contractor_Registration_Paripatra__1_.pdf
GR for Extra Item.pdf
GR for single Tender.pdf
SD EMD GR 25-26.pdf
ONLINE_NOTICE(R-2).pdf
SBD.pdf
SCH-B.pdf
DM.pdf
ANNEXURE-A .pdf
Electrical_Tender_Conditions.pdf
MAKE FOR ELECTRICAL ITEM.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .