| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.0 LAccepted-AOC NEAR DOON INSTITUTE BHALLA FARM SHYAMPUR RISHIKESH DEHRADUN UK 249 204 | DEHRADUN | DEHRADUN | UTTARAKHAND | 249204 | L1 | Accepted-AOC Contract Awarded being Lowest Bidder. | |
| 2 | L2₹28.1 L+₹1.3 L (4.74%)Rejected-AOC 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | L2 | Rejected-AOC Rejected due to Higher Amount Quoted. | |
| 3 | L3₹30.2 L+₹3.4 L (12.5%)Rejected-AOC G 16 JAY COMPLEX BELOW UMA CO OP BANK NIZAMPURA VADODARA GUJARAT 390002 | VADODARA | VADODARA | GUJARAT | 390002 | L3 | Rejected-AOC Rejected due to Higher Amount Quoted. | |
| 4 | L4₹32.3 L+₹5.5 L (20.6%)Rejected-AOC 4 A RUKSHMANI PARK SOCIETY OPP SAMA WATER TANK NEW SAMA ROAD VADODARA 390 008 | VADODARA | VADODARA | GUJARAT | 390008 | L4 | Rejected-AOC Rejected due to Higher Amount Quoted. |
| Sl No | Description | Qty | Unit | BK CONSTRUCTION L1 | Rasam Engg Co. L2 | Gayatri Associates L4 | City Light L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches not exc. 1.5m wide and not exc. 1.5 metre deep and getting out in soft/loose soil complete all as specified and directed.
Note: (i) During the excavation damage of road, Electric cable, signal cable and sewage line should be repaired by the contractor without any extra coast and surface should be matched as existing surface. | 116.6 | CUM | 240 ₹27,984 | 225 ₹26,235 Lowest | 225 ₹26,235 Lowest | 250 ₹29,150 |
| 2.00 | Returning, filling in including spreading, watering and well ramming in layers not exc 25cm in soft/loose soil complete all as specified and directed. | 77.86 | CUM | 80 ₹6,228.8 | 50 ₹3,893 | 45 ₹3,503.7 | 25 ₹1,946.5 Lowest |
| 3.00 | Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point. | 38.74 | CUM | 120 ₹4,648.8 | 50 ₹1,937 | 55 ₹2,130.7 | 25 ₹968.5 Lowest |
| 4.00 | Material & Labour for sand cushioning for under ground cable with locally available sand for protection of cable 8cm before laying cable and 15cm deep over the cable including spreading and onsolidations, complete all as specified and directed.
(Note-Punned thickness ie 18 mm will be measured and paid) | 22.72 | CUM | 1,250 ₹28,400 | 750 ₹17,040 Lowest | 825 ₹18,744 | 750 ₹17,040 Lowest |
| 5.00 | Supplying and laying unreinforced precast concrete cable cover, class HV, type 2, flat size 450mm x 180mm x 40mm | 1,617 | Each | 55 ₹88,935 | 65 ₹1,05,105 | 35 ₹56,595 Lowest | 50 ₹80,850 |
| 6.00 | Supply and Fixing pipe galvanised iron light grade (ISI marked) with all fittings laid in trenches or on pole, crossing of road, fixed on wall for protection of cable complete all as specified and directed of 80mm dia. | 32 | RM | 850 ₹27,200 | 650 ₹20,800 Lowest | 1,275 ₹40,800 | 1,250 ₹40,000 |
| 7.00 | Taking out unserviceable cable any type/size from trenches, pole road, duct etc including necessary joints, unserviceable fittings, cable protection cover and pipes etc complete. Note: Excavation and earthwork shall be measured & paid for seperatly under respective item of this schedule of work. | 370 | RM | 90 ₹33,300 | 50 ₹18,500 | 25 ₹9,250 | 10 ₹3,700 Lowest |
| 8.00 | Supply, laying, commissioning and testing in repairs of XLPE insulated, seceened, PVC bedded, galvaniseD steel strip or wire armoured heavy duty electric power cable with aluminium conductor, 6.35/11 KV suitable for 11000 volts grade, cross-sectional area 95 sqmm 3 core complete all as specified and directed. | 370 | RM | 1,050 ₹3,88,500 | 1,220 ₹4,51,400 | 1,050 ₹3,88,500 | 950 ₹3,51,500 Lowest |
| 9.00 | Dismantling and taking down of end termination/ straight through cable joint of any size any type. | 42 | Each | 100 ₹4,200 | 200 ₹8,400 | 20 ₹840 | 10 ₹420 Lowest |
| 10.00 | Material & Labour for replacement of cable jointing kit for 11 kV grade (Earthed) HT cable for indoor termination cold shrinkable type complete with jointing material and accessories suitable for 3 core x 95 Sqmm XLPE armoured aluminium conductor cable of following sizes complete all as specified and directed by EIC. | 12 | Each | 11,500 ₹1,38,000 | 8,500 ₹1,02,000 | 3,500 ₹42,000 Lowest | 4,000 ₹48,000 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
17 Sept 2025, 6:00 pmClosed
CWE AHMEDABAD
CWE AHMEDABAD
REPAIR/ MAINTENNANCE OF HT EQUIPMENTS, HT CABLE AND CONNECTED WORK AT SECTOR A, B AND C UNDER GE (A) BARODA
2025_MES_726841_1
87418/E8
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
ARMY AREA BARODA
AS PER TENDER DOCUMENT
6 documents required · 6 mandatory
₹500
GE (A) BARODA
₹60,000
Yes
16 Oct 2025
20 Aug 2025
25 Sept 2025
20 Aug 2025
17 Sept 2025
4 Sept 2025
20 Aug 2025 - 3 Sept 2025
Amount
Excavating in trenches not exc. 1.5m wide and not exc. 1.5 metre deep and getting out in soft/loose soil complete all as specified and directed. Note: (i) During the excavation damage of road, Electric cable, signal cable and sewage line should be repaired by the contractor without any extra coast and surface should be matched as existing surface.
Returning, filling in including spreading, watering and well ramming in layers not exc 25cm in soft/loose soil complete all as specified and directed.
Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point.
Material & Labour for sand cushioning for under ground cable with locally available sand for protection of cable 8cm before laying cable and 15cm deep over the cable including spreading and onsolidations, complete all as specified and directed. (Note-Punned thickness ie 18 mm will be measured and paid)
Supplying and laying unreinforced precast concrete cable cover, class HV, type 2, flat size 450mm x 180mm x 40mm
Supply and Fixing pipe galvanised iron light grade (ISI marked) with all fittings laid in trenches or on pole, crossing of road, fixed on wall for protection of cable complete all as specified and directed of 80mm dia.
Supply, laying, commissioning and testing in repairs of XLPE insulated, seceened, PVC bedded, galvaniseD steel strip or wire armoured heavy duty electric power cable with aluminium conductor, 6.35/11 KV suitable for 11000 volts grade, cross-sectional area 95 sqmm 3 core complete all as specified and directed.
Dismantling and taking down of end termination/ straight through cable joint of any size any type.
Material & Labour for replacement of cable jointing kit for 11 kV grade (Earthed) HT cable for indoor termination cold shrinkable type complete with jointing material and accessories suitable for 3 core x 95 Sqmm XLPE armoured aluminium conductor cable of following sizes complete all as specified and directed by EIC.
All as per item 10 Above but 95 sqmm out door type.
All as per item 10 above but for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm, straight through type.
Supply, Jointing and testing in repair cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120-185 Sqmm all as per manufacturer's recommendations complete all as specified and directed.
Supply, jointing and testing in repair cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120-185 Sqmm all s per manufacture's recommendations complete all as specified and directed.
Supply and Fixing Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour with voltage 33000V/11000V as indicated and fixed with M.S. clamps, bolts and nuts of approved size, for HT size 25X20 cm all specified and directed by Engr-in-Charge.
Matrial and Labour for rubber mat of size 1mtrX2mtrx10mm suitable for 11 KV sub station complete all as specified.
Supply only electric hand gloves rubber suitable for 11 KV line complete all as specified.
Supply only safety Helmet with slide-strap adjustment yellow complete all as specified.
Supply only telestone type fibre glass discharge rod suitable for 11/33 KV line complete all as specified.
Detecting of fault of HT UG cable (any place any length any type /size) with help of vehicle mounted cable fault locator including detecting exact location of cable fault and remove of cable for rectification. Note:-Cable fault locator shall be aggranged within 2 days from of intimation by Engineer-in-charge otherwise Penalty of RS 2000/day will be levised for each day of delay for for every segment of cable . If fault not located no payment shall be made to contractor.
Disconnecting and taking out existing HT 11 KV (VCB) from housing and cleaning, rubbing and overhauling the mechanical parts including greasing, oiling, replacement of unserviceable Trip coil, Breaker charging motor, gear pinion, roller switch, big gear checking of SF6 quality of vacuum interrupter, insulation resistances, static contact resistance etc and re-assembling the same after requir and made the VCB serviceable including making all electrical connection and testing (IR value, Ratio test, polarity test) and connection verification of 11 KV current transformer (set of three) by PRIMARY INJECTION KIT and testing and calibration of relay (set of two over current and one earth fualt) by SECONDARY INJECTION KIT including all other functional tests of the VCB, C&R panel and CTs, PTs. complete all specified and directed. Note :- (i) All spares parts of VCB panel shall be measured and paid for separately under relevent item as supply only. (ii) The repair work and testing of VCB shall be carried out by the representative of OEM only. (ii) Relay test record shall be submitted with signature of Engineer-in-Charge, JE and Contractor.
Supply only breaker charging motor including gear assembly 220 volt AC of 11 KV VCB panel. Make: ABB or make
Supply install , testing and commissioning of closing coil suitable for 11 KV HT VCB of make L & T 110V DC complete all as specified and directed.
Supply install, testing and commissioning of Triping coil suitable for 11 KV HT VCB of make L & T 110V DC complete all as sspecified and directed.
Supply install, testing and commissioning of Power Pack , 230V AC input, 110V DC output, 100VA suitable for 11 KV HT VCB of make L & T 110V DC complete all as specified and directed.
Supply install, testing and commissioning of 11 KV, indoor CT 100 A/50A+1A ACC Class 5P ratio suitable for VCB of Make-ABB or equivalent model of make
Supply install, testing and commissioning of 11 KV, indoor PT 110 V suitable for SF6 VCB of Make-ABB or equivalent model of make
Supply & Fixing in repair 11 KV panel indicating lamp fitting RYB LED type suitable for 12/24 volt DC complete with base complete all as specified ad directed.
Supply & Fixing in repair 11 KV VCB panel volt ampere frequency meter digital type suitable for 12/24 volt DC complete with base complete all as specified ad directed.
Supply, fixing and testing 11 KV bus insulator suitable for 11 KV SF6 VCB Panel complete.
Earthing complete with galvanized steel earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below ground level connected to galvanized iron earth strip of size 32x6mm by means of bolt, nut, check nut and washer of galvanized iron or steel protected by galvanized iron pipe of 40 mm bore medium grade, incl. Funnel, 20mm dia bore galvanised iron pipe medium grade for watering, wire mesh, charcoal or coke and common salt in alternative layers all around the earth electrode compacted thickness 15 cm incl. Excavation and earth work, PCC 1:3:6 type C-1, CI pit cover, incl disposal of surplus soil to a distance n.exc. 50 m complete testing on completion, all complete as shown in electrical plate No. 3 of MES SSR Part-I all as specified. Note :- (i) Cost of earth strip and GI protection pipe up to a distance 7.5 metre shall be included in the quoted rate. (ii )On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
Supply, fixing and testing 11 KV HT ceramic bushing of transformer 11 KV/433 volt indoor/outdoor of various capacities complete all as specified and directed by Engineer-in-Charge including taking out old bushing.
Supply fixing and testing ceramic bushing LT side of transformer 11 KV/433 volt indoor/outdoor of various capacities ie upto and including 350 KVA complete all as specified and directed by Engineer-in-Charge including taking out old bushing.
Supply, fixing and testing bushing rod of brass both ends threaded including nut, check nut and washer LT side of transformer 11 KV/433 Volt indoor/outdoor of various Capacity upto and including 350 KVA complete the same all as specified and directed by Engineer-in-Charge including taking out old bushing rod.
Supply & fixing in repair gasket set of synthetic rubberized cork sheet 10 mm thick for transformer top lid cover suitable for transformer of capacity upto 350 KVA.
Painting of transformer after cleaning the body surfaceof transformer by rubbing with emery paper to remove oil strains, dust etc and applying two coat of heat resistance paint by spray paint incl writing SM/MES no and capacity of transformer of capacity upto 350 KVA complete.
Supply only transformer oil of approved quality as per IS No : 335-1993 low viscosity type having dielectric strenght of more than 60 KV in 2.5 mm gap for toping up complete all as specified and directed (Make : Castrol, Power oil, gulf as approved by GE
Supply & Fixing in replacement breather assembly complete with 250 grams silica gel suitable for any capacity / model of transformer to air column of conservator tank complete all as specified and directed.
Supply & Fixing in replacement breather assembly complete with 500 grams silica gel suitable for any capacity / model of transformer to air column of conservator tank complete all as specified and directed.
Rewinding of LT/HT coil, conforming to the orginal winding of the transformer of any make/capacity with super enamelled DPC insulated copper wire/strip of appropriate guage and turns and cutting and moving of burnt winding cleaning of core and drying in over after assembly including allied materials complete all as specified and directed. Note :- (i) Old retrieved materials shall be contractors property and necessary amount as per schedule of credit shall be deducted from contractor's dues. (ii) Rewinding work shall be carried out through OEM authorised representative. (iii) The repair work under each transformer shall be ordered by GE in writting after visual inspection on opening of transformer.
Supplying and fixing aluminium strip 32x6mm, fixing with screws, including making holes for cable/thimbles as required complete all as specified
Supply and fixing in replcement of HT jumper of 70 Sqmm single core aluminium cable conductor incl PG clamps, nut bolts, thimbles and washer required at site complete all as specified and directed.
Supply and Fixing for replacement of temp gauge 0-100 degree C suitable for existing fitment of transformer 33 and 11/0.433 KVA complete all as specified and directed.
Supply and Laying and spreading of 40mm graded stone aggregate complete all as specified and directed.
Material and labour for cutting of vegetation surrounding transformer , two poles, four pole structure at various sub station/E&M installation and remove to a distance not exc 50 mtr all as directed. Note: The installation should be cleaned/maintained twice in during the contract.
Preventive maintenance for indoor and outdoor type RMU 3 way comprising preventive maintenance activities and repairing the RMU during breakdown / emergency and routine testing all as specified below:- Note:- Quoted rates shall be deemed to include for the following:- (i) Preventive maintenance shall be carried out one time in year. (ii) Contractor shall also responsible for repairing the RMU during any breakdown / emergency. (iii) routine testing shall be carried out once in a year.
(i) RMU of make L&T & Crompton are installed at site. Preventive maintenance, repairing the RMU during breakdown / emergency and routine testing shall be carried out through authorised representative OEM all as specified and directed by Engineer-in-Charge.
(ii) Spare parts required for Preventive maintenance, repairing the RMU during breakdown / emergency will be measured & paid separately as supply & fix in repair. Make of spare part shall be as recommended by the OEM.
(iii) Contractor shall submit necessary documentary evidence that Preventive maintenance, repairing the RMU during breakdown / emergency and routine testing has been performed by the OEM
(vi) RMU any type any way including VCB, load break switch and metering unit will be measured as one unit for payment.
(v) After Preventive maintenance, repairing the RMU during breakdown / emergency RMU shall be tested as directed by the Engineer-in-Charge and test result in triplicate copy shall be submitted to Engineer-in-Charge
(Note: Item no 1 to 48 If any above HT cables and connected items become breakdown, the contractor shall loacate the problem/fault at site within 12 hours on intimation by JE/Engineer-In-Charge and ensure that the fault and rectified within 24 to 48 Hours , failing which an amount of Rs 500 /- per hour will be recovered as penal recovery from any payment due to the contractor after expiry of 48 hours.)
Rasam Engg Co. (BID ID -3427998)
City Light (BID ID -3428305)
Gayatri Associates (BID ID -3428304)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .