Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.3 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹37.3 L+₹2.5 L (7.29%)Rejected-Finance CHANDMARI WARD NO 19 PO PS TEZPUR DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | L2 | Rejected-Finance Become L2 | |
| 3 | L3₹39.0 L+₹4.2 L (12.2%)Rejected-Finance | L3 | Rejected-Finance Become L3 | |
| 4 | L4₹40.7 L+₹6.0 L (17.2%)Rejected-Finance NIL | L4 | Rejected-Finance Become L4 | |
| 5 | L5₹41.5 L+₹6.7 L (19.4%)Rejected-Finance | L5 | Rejected-Finance Become L5 |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
12 May 2022, 6:00 pmClosed
GE South Tezpur
GE South Tezpur Mission Chariali Tezpur, Assam
REPAIR /MAINTENANCE OF COOLING APPLIANCES WITH OTHER CONNECTED WORKS UNDER GE (S) TEZPUR
2022_MES_519633_1
8652
Open Tender
Civil Works
Item Rate
180 days
GE South Tezpur
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE South Tezpur
₹70,000
Yes
14 Jul 2022
23 Apr 2022
14 May 2022
23 Apr 2022
12 May 2022
6 May 2022
Amount
Air Conditioner M&L for taking out u/s air conditioner window/ split type in cappacity 1.5 and 2 Ton for replacing to u/s spares /re-painting /servicing/ carrying out neccessary repairing works/ shifting location/ gas re-filling etc in any type/ cap/ make /model all as site with connecting accessories from existed location after removing all connections safely and transportation from site to work shop and back (if required) at same after repairing work complete all as directed. Note :- Connecting accessories will be taken in safy custody by contractor for re-using at same. (ii) All spaires shall be measured and paid against respective items .
M&L for dusting, cleaning by compressed air, washing using casting soda mixed water after scraping to old paint coat to be preparing the surface for re-painting to air condioner in any type /make/ model/ cap/ etc all as site using heat resistive/ synthetic enamel paint by paint spray gun in two coats over one coat of red oxide primer and indication marking by diffirent colour in standard size of letter complete all as directed . Note :- (i) Paint colour shall be approved by Engr-in-charge. (ii) All spares required to servicing shall be measured and paid sepretly.
Supply and re- filling/ charging of refrigerant gas of R-134A,R-32, R-410A, R-22 in origional to window or split type air conditioner upto 2 Ton capacity upto speicific pressure /grade complete all as directed. Note : Grade of refrigerant shall be supplied as per model /make requirement in origional.
Labour for re- fixing / installation/ connecting/ testing and commissioning of repaired air conditioner under above item in origional postion all as same as per exsited including making electric / air connections with other site required work for serviceablity complete all as directed .
M&L for making hole to be fitted window air condioner for any type/ make/ model / capacity etc. after cutting window's net made out by MS bar or strip / brick wall etc incl all type all required insulating/ fixing materials such as thermocoal/ peice of plywood etc complete all as site and directed. Note :- Quoted rate shall be included making good to disturbed surface as exisiting.
Supply and fixing in replacement of under mentioned spares suitable for air conditioner in window / split type of cap 1.5 to 2 Ton as required in origional manufactures complete all as directed. Note :- (i) All spares shall be hold original manufacture tag with cat no. (ii) Spare supplied shall be as per the sample kept in GE office as per OEM. All as above item No 6 for rotary DC compressor unit for invertor window type cap upto 2 Ton.230 V, Single Phase Complete all as specified and as directed,
All as above item No 6 for rotary DC compressor unit for invertor split type cap upto 2 Ton.230 V, Single Phase Complete.
All as above item No 6 for reciprocating / rotary AC compressor unit for window type cap upto 2 Ton.230 V, Single Phase Complete all as specified and as directed,
All as above item No 6 for reciprocating / rotary AC compressor unit for split type cap upto 2 Ton.230 V, Single Phase Complete all as specified and as directed,
All as above item No 6 for Starting/Running Capatior for Existing model of split/ window AC. Make: Sarda, Unistar, Tibcon, Asian, Epcos.
All as above item No 6 for condenser unit for window type
All as above item No 6 for indoor unit blower fan motor for split type cap 1.5 Ton.
All as above item No 6 for out door unit fan motor for split type cap 1.5 Ton.
All as above item No 6 for indoor unit fan blower motor for split type cap 2 Ton.
All as above item No 6 for out door unit fan motor for split type cap 2 Ton
All as above item No 6 for blower fan motor for window AC cap 1.5/2 Ton
All as above item No 6 for PCB outdoor for split type AC cap 1.5/ 2 Ton. As per site requirement.
All as above item No 6 for PCB indoor for split type AC cap 1.5/ 2 Ton with remote Control.
All as above item No 6 for PCB for window type AC cap 1.5/ 2 Ton.
All as above item No.6 for DC stapping motor.
All as above item No.6 for thermostate assembly.
All as above item No.6 for indoor condensestion unit for split type 1.5 Ton AC .
All as above item No.6 for outdoor condensestion unit for split type 1.5 Ton AC.
All as above item No.6 for indoor condensestion unit for split type 2 Ton AC.
All as above item No.6 for outdoor condensestion unit for split type 2 Ton AC.
All as above item No.6 for relay for AC for window /split type cap 1.5/ 2 Ton.
All as above item No.6 for front panel grill.
All as above item No.6 for Remot control suitable for as site unit.
All as above item No. 6 for automatic sensor card.
All as above item No. 6 for Capacitor for Fan motor.
S&F in replacement of Air filter for split/ window type AC.
S&F in replacement of swing motor for indoor unit of split/window AC.
M&L Flyshing and leak testing of complete system with Nitrogen gas and topping up compressor oil.
S&F in replacement for blades of model of existing/ suitable model of window/ split type (outdoor Unit) of capacity up to 2 TR
M&L for servicing,oiling, greasing, cleaning, dusting ,overhauling etc all as site requirement works for air conditioner in all make/type/ model /cap upto 2 Ton etc for making serviceable with satisfactions including disconneting, removing, re-fixing ,and re-connecting all as site and directed.
M&L for replacing to rusted body portion/part of air conditioner in all make/ model / capacity etc as site using MS sheets minium 18 gauge for body and angle for frame work including jointing welding cutting etc all works finishing/ painting to matching with existing surface complete all as directed.
Water cooler/ refiregator and De- freezer Labour for taking out u/s water cooler/ refrigerator and deep- freezer of any make/ model/ capacity etc for replacing to u/s spares /re-painting /servicing/ carrying out neccessary repairing works/ shifting location/ gas re-filling etc in any type/ cap/ make /model all as site with connecting accessories from existed location after removing all connections safely and transportation from site to work shop and back (if required) at same after repairing work complete all as directed. Note :- (i) Connecting accessories will be taken in safy custody by contractor for re-using at same. (ii) All spaires required shall be measured separately as S&F and hence no labour element for replacement of such item shall be taken under this item.
M&L for servicing,oiling, greasing, cleaning, dusting overhauling to water cooler/ refrigerator and deep- freezer in any make/ model/ capacity etc all as site requirement works for in all make/type/ model /cap etc for making serviceable with satisfactions including disconneting, removing, re-fixing ,and re-connecting all as same at site and directed.
M&L for replacing to rusted body portion/part of refrigerator/ water cooler/ deep- freezer etc in all make/ model / capacity etc as site using MS sheets minium 18 gauge for body and angle for frame work and base unit including jointing welding cutting etc all works finishing/ painting to matching with existing surface complete all as directed.
Supply and fixing in replacement of under mentioned spares suitable for refrigerator/ water cooler/deep- freezer in any capacity / make/ model/ type etc as site in origional manufactures complete all as directed. Note :- (i) All spares shall be hold original manufacture tag with cat no. (ii) Spare will be suitable for all capacity and Make LG / Voltas/ Blue star/ Usha/ Vidiocon/ Usha/ Sumsang / Annapurna / whirlpool/ Gojrej/ Danfoss / Tecumseh etc as site. (a) Compressore unit for 40 to 80 ltr storage capacity. Make - Kirloskar/ Tecumseh / Godrej / Whirlpool
All as above item No 41 but compressor unit for 150 ltr storage capacity. Make - Kirloskar/ Tecumseh / Godrej
All as above item No 41 but compressor unit for 165 /205 ltrs capacity Make - as per sample with origional tag
All as above item No 41 but compressor unit for 286/300 ltr capacity. Make - as per sample with origional tag
All as above item No 41 but evaporator assembly single/ double door refrigerator capacity upto 205 Ltr. Make - as per sample with origional tag
All as above item No 41 but evaporator assembly single/ double door refrigerator capacity 280 to 300 Ltr .Make - as per sample with origional tag
M&l for servicing/ cleaning, dusting, overhauling , oiling etc all to make in serviceable to refrigerator/ water cooler or deep- freezer in any make/ model/ capacity/ rating etc all as site complete as directed.
All as above item No 41 but evaporator assembly water cooler/ deep- freezer capacity upto 205 Ltrs
All as above item No 41 but evaporator assembly water cooler/ deep- freezer capacity 280 to 300 Ltrs
All as above item No 41 but Duct assembly double door.
All as above item No 41 but driyer for refrigerator.
All as above item No 41 but motor DC single/ double door
All as above item No 41 but power cord single/ double door
All as above item No 41 but controller assembly single/ double door
All as above item No 41 but over load unit.
All as above item No 41 but main PCB for single/ double door refrigerator of any capacity.
All as above item No 41 but thermostate big/ small
All as above item No 41 but condensation unit
All as above item No 41 but bulb & holder
All as above item No 41 but door lock and key
All as above item No 41 but gasket or door bedding rubber for complete inner/outer unit.
All as above item No 41 but relay suitable Make ;- Renetol/ Shriram/ Dun Foss / Godrej
All as above item No 41 but capacitor/ condensor.
All as above item No 41 but blower motor
All as above item No 41 but chiller/ ice tray
All as above item No 41 but vegitable tray
All as above item No 41 but copper capillary cooling coil tube assembly
All as above item No 41 but replacing to door hinges as origional
All as above item No 41 but door/ stand rubber cusion pad set
All as above item No 41 but temprature controll panel
All as above item No 41 but PVC mounting stand for refiregetor
All as above item No 41 but Timer assembly
Supply and re-filling of refrigerant gas by providing 500 gram in origional to refrigerator/ water cooler/deep- freezer etc in any capacity / make/ model etc all as site by speicific pressure complete all as directed.
Water heater or Geyser :- M&L for taking down water heater / geyser in any make/ model/ type/ size etc as site and open to body / connecting parts for repair/ replaing to u/s spares ,servicing , cleaing, overhauling, painting etc all as site after removing connections complete all as specified. Note : (i) Spares shall be measured and paid seprately. (ii) Quoted rate shall be included transpotion charge in required (if required)
M&L for re-fixing and connecting to geyser after replacing to u/s spares , ,servicing ,overhauling, painting etc all as site including new nut bolts and washer etc as site required and making electric connection using 3 core copper cable drawn through in PVC flexible conduit pipe and water connection as same at site all as specified and directed. Note ;- Nut bolts and washer for fixing to geyser shall be suppy by contractor if required.
M&L for painting to water heater / geyser in any make/ model/ size/ capacity using two coats over one coat of red oxide primer using syenthetic enamel/ heat resitance paint after washing with casting soda water ,scarping to old paint, cleaning etc and identy marking by different colour as per exisiting complete all as specified and directed. Note :- Colour of paint shall be approved by Engr-in- charge.
S&F under mentioned spares suitable for water heater/ geyser in any type /capacity / model /make /size etc as required in origional manufactures complete all as directed. Note :- (i) All spares shall be hold original manufacture tag with cat no. (ii) Spare will be suitable for Make Voltas/ Blue star/ Havells/ Bajaj / Usha etc all as site. (a) B ase assmebly for 25 Ltrs capacity inlet and outlet of geyser made out of copper base plate with gasket, nuts, bolts and washer etc.
All as above item No 77 but base assmebly for 50 Ltrs capacity inlet and outlet of geyser made out of copper base plate with gasket, nuts, bolts and washer etc.
All as above item No 77 but water heating element for 1.5/2KW cap Trinangular and round type.
All as above item No.77 but Thermostate asssembly manually adjustment type setting range with 35 to 65 CC. adjustable type.
All as above item No. 77 but auto temperature cut out unit
All as above item No 77 but indicator lamp 220 Volts AC
All as above item No 77 but safety pressure release valve.
All as above item No.77 but PVC float valve with epoxy coated aluminium arm , with PVC polythene ball suitable for water coolers.
All as above item No.77 but inter connection pipe with metal sockets at both end in and for 90 cc hot water ISI mark.
All as above item No. 77 but PVC inter connection pipe with metal sockets at both end in 600 mm length.
M&L for replacing to rusted body portion/part of geyser in make/ model / capacity etc as site using MS sheets minium 18 gauge for body and angle for frame work and base unit including jointing welding cutting etc all works finishing/ painting to matching with existing surface complete all as directed.
S&F in replacement of fan hook /clamps made out by GI strip 20 mm width 4 mm thick incl cutting, bending, fitting, painting ,nut bolts washers etc all as site suitable for fitting to ceiling fan complete all as directed.
S&F in replacement bib tap Cast copper alloy with crutch or butterfly handle, screwed for iron pipe 15 mm push type chromium plated. Make:- Sona.
S&F in replacement of PVC insulated sheathed multistandred copper conductor cable 3 core 4 sqmm 1100 Volts grade. Make - Finolex/ Plaza/ Havells
S&F in replacement of PVC insulated sheathed multistandred copper conductor cable 3 core 2.5 sqmm 1100 Volts grade. Make - Finolex/ Plaza/ Havells
S&F in replacement of PVC insulated sheathed multistandred copper conductor cable single core 4 sqmm 1100 Volts grade. Make - Finolex/ Plaza/ Havells
Supply and fixing in replacement of new water heater (Gyser) storage type, single phase, energy saving 5 star rated 230 volts grade 5 star rated 25 Ltrs storage capacity complete with chomium inter connecting pipe , nutt, bolts , washers and other site required accessories. Note : Quoted rate shall be included nutt bolt and washer,inter connection pipe set with all other required accessories. Make :- Havells, Bajaj, CG, Usha
All as above item No 93 but here-in-before but capacity 10 ltrs. Make - Havells, Bajaj, CG, Usha
Supply and fixing/ laid/ clamping of wall etc as site galvasined steel tubing with all fittings in medium grade bore of dai 15 mm all as specified and directed. Make :- Tata/ Jindal/ NTL
Supply and fixing/ laid/ clamping of wall etc as site galvasined steel tubing with all fittings in medium grade bore of dai 20 mm all as specified and directed. Make :- Tata/ Jindal/ NTL
Shifting and installation of split/window type AC any make/capacity at one place to another place as directed by Engineer-in-charge.
Supply and fixing/ laid/ concealed clamping of wall etc as site copper pipe for suction/Discharge line with all fittings in bore of 1/2,1/4, 5/8, 3/4 all as specified and directed.
Supply and fixing and connecting inreplacement of fully automatic single phase naturally air cooled indoor type wall mounting type digital voltage stabilizer voltage variation between 130 to 300 volts with output voltage stabilizer at 230 v with accuracy of +/- 2.5% of capacity 5 KVA (suitable up to 2 Ton or 24000 Btu/Hr) W TDR all as specified and directed Make : V-Guard model VD 500 in equivelent Mocrotek/AE/Vintex
All as above item No 100 but of capacity 4 KVA (suitable up to 1.5 Ton or 24000 Btu/Hr) W TDR all as specified and directed Make : V-Guard model VD 500 in equivelent Mocrotek/AE/Vintex Note 1:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount. Note 2-Contractor's supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embosed with contractor's firm name while carriying out any activities in defence area for better check of security purpose. Note 3:-The tenderer (all eligible contractors) shall ascertain the taxes & levies as on date. The subject tender caters all the taxes & levies as on date including the latest notification of GST issued as on date ( issued by Central Board of Indirect Taxes and Customs)
MAHANTA ENTERPRISES
M/S Deep-Jeet
M/S N S CONSTRUCTION
DRISTEE ASSOCIATES
M/s Brahamaputra Wood Industries
D G Corporation
MD. LATIFUL AHMED HUSSAIN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .