Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC 26 2579 THEVARA PO KOCHI ERNAKULAM KERALA 682013 | KOCHI | ERNAKULAM | KERALA | 682013 | ₹10.7 L Quoted ₹11.8 L | L1 | Accepted-AOC Being Lowest Tenderer |
| 2 | L2₹13.9 LRejected-Finance D NO CC XX 1487 B1 CC 18 1786 B1 NEAR VVLP SCHOOL KONAM PALLURUTHY P O KOCHI 682006 | ERNAKULAM | KERALA | 682006 | ₹13.9 L | L2 | Rejected-Finance Other than Lowest Tenderer |
| 3 | L3₹14.2 LRejected-Finance 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | ₹14.2 L | L3 | Rejected-Finance Other than Lowest Tenderer |
| Sl No | Description | Qty | Unit | AR Traders L1 | COCHIN CHEMICALS L2 | Jack Electrolinks Private Limited L3 |
|---|---|---|---|---|---|---|
| 1.00 | Material and labour for attending day to day complaints pertains to various capacity of cooling appliances and equipments as and when site requirement and complaints arises by arranging Highly skilled Mechanic - 01 No with helper - 01No. Work includes for all type of cooling appliances, equipments like all type of ACs, all type of Refrigerators, deep freezers, Water coolers etc. handling with repairs, maintenance, timely replacement of spare parts, testing, smooth functioning of equipments, including necessary tools and plants for checking the equipments at existing location, find out the faults complete and rectification of minor problems, electric loose connections, (compressor control panel resetting with electrical components like replacement of lugs/pin, MCB resetting, electrical wiring connections gas top up (gas shall be measured and paid separately under relevant item) ,to make the cooling appliances/ equipments functional in all respect complete all as specified and as directed by the Engineer -In- Charge.
Notes:
1.Complaints/services schedule list shall be collected from concerned JE/Engineer-In Charge and report back on daily basis.
2.The Serial item Nos of BOQ 02 to 75, of BOQ shall be outside the scope of this item.
3.A penalty of Rs. 500/- per day will be levied in case breakdown of equipment more than 3 working hours from the time of complaint registration due to non-attending.
4.The Item shall be measured and paid only for detecting the faults and for rectifications works. If any spare replacement needed in the work, the same shall be measured and paid under relevant item. | 150 | Each Job | 300 ₹45,000 | 400 ₹60,000 | 450 ₹67,500 |
| 2.00 | Supply and fix factory built hermetically sealed compressor unit suitable for 1.5 Ton, single phase, 230 V, 50Hz capacity split / window type AC, testing the leak of compressor by charging Dry Nitrogen gas, evacuating the system and charging R-22 /304 a /407a /134 Refrigerant gas including taking out old unserviceable compressor with connected old material from the split type ACs / window ACs complete all as specified and as directed. | 6 | Each Job | 9,000 ₹54,000 | 13,400 ₹80,400 | 8,500 ₹51,000 |
| 3.00 | `-Ditto- all as per item No 02 here in above but 2.0 TR | 3 | Each Job | 9,500 ₹28,500 | 14,000 ₹42,000 | 12,500 ₹37,500 |
| 4.00 | `-Ditto- all as per item No 02 here in above but from 2.5 TR to 3.0 TR | 2 | Each Job | 15,000 ₹30,000 | 14,850 ₹29,700 | 16,500 ₹33,000 |
| 5.00 | Material and labour for leak testing of Window / Split type ACs, Water cooler, Refrigerator, Deep freezer etc. including filling of nitrogen gas for pressure testing, finding leaks, Vacuuming the system, necessary brazing work, charging with refrigerant gas ( R-22 / R 304 a /R 407a /R 134 ) of required quantity, testing for proper functioning complete all as specified as directed | 40 | Each Job | 1,000 ₹40,000 | 880 ₹35,200 | 2,500 ₹1 L |
| 6.00 | Material and labour for onsite servicing 1.5 / 2.0 / 2.5/ 3.0 Ton capacity split/ window type AC of any description by cleaning air filter, cooling coil/ condenser coil and outer cabinet with pressurised water and detergent solution, applying new insulation to torn/damaged insulation complete all as specified and as directed. | 50 | Each Job | 100 ₹5,000 | 910 ₹45,500 | 1,500 ₹75,000 |
| 7.00 | Supply and fix in repairs of condenser fan motor with capacitor and mounting materials, single phase, 230 Volts, 50 Hz suitable for 1.0/1.5/2.5 /3.0 Ton capacity split type AC including taking out old unserviceable blower motor complete all as specified and as directed. | 13 | Each | 2,500 ₹32,500 | 1,500 ₹19,500 | 3,500 ₹45,500 |
| 8.00 | Supply and fix in repairs of thermostat cut off switch suitable for 1.5 / 2.0 / 2.5/3.0 Ton capacity split / window type AC complete all as specified and as specified and as directed. | 24 | Each | 100 ₹2,400 | 700 ₹16,800 | 550 ₹13,200 |
| 9.00 | Supply and fix in repairs of overload protective relay suitable for 1.5/2.0/2.5/3.0 Ton capacity window type AC complete all as specified and as directed. | 20 | Each | 100 ₹2,000 | 460 ₹9,200 | 350 ₹7,000 |
| 10.00 | Supply and fix in repairs of starting relay suitable for 1.5 /2.0/2.5/3.0 Ton capacity window type AC complete all as specified and as directed. | 20 | Each | 100 ₹2,000 | 385 ₹7,700 | 400 ₹8,000 |
Updated dates
Tender Value
₹14.3 L
EMD Value
₹28,500
Closing Date
13 Nov 2025, 6:00 pmClosed
GE FORT KOCHI
GARRISON ENGINEER MILITARY ENGINEER SERVICES GE FORT KOCHI -682 001
REPAIR/MAINT OF COOLING APPLIANCES LIKE SPLIT ACs, WATER COOLERS, DEEP FREEZERS ETC AT INS DRONACHARYA UNDER GE FORT KOCHI
2025_MES_735473_1
8275/E8_GE_FORT_KOCHI
Open Tender
Electrical and Maintenance Works
270 days
FORT KOCHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE FORT KOCHI
₹28,500
Yes
30 Dec 2025
16 Oct 2025
20 Nov 2025
16 Oct 2025
13 Nov 2025
30 Oct 2025
Amount
Material and labour for attending day to day complaints pertains to various capacity of cooling appliances and equipments as and when site requirement and complaints arises by arranging Highly skilled Mechanic - 01 No with helper - 01No. Work includes for all type of cooling appliances, equipments like all type of ACs, all type of Refrigerators, deep freezers, Water coolers etc. handling with repairs, maintenance, timely replacement of spare parts, testing, smooth functioning of equipments, including necessary tools and plants for checking the equipments at existing location, find out the faults complete and rectification of minor problems, electric loose connections, (compressor control panel resetting with electrical components like replacement of lugs/pin, MCB resetting, electrical wiring connections gas top up (gas shall be measured and paid separately under relevant item) ,to make the cooling appliances/ equipments functional in all respect complete all as specified and as directed by the Engineer -In- Charge. Notes: 1.Complaints/services schedule list shall be collected from concerned JE/Engineer-In Charge and report back on daily basis. 2.The Serial item Nos of BOQ 02 to 75, of BOQ shall be outside the scope of this item. 3.A penalty of Rs. 500/- per day will be levied in case breakdown of equipment more than 3 working hours from the time of complaint registration due to non-attending. 4.The Item shall be measured and paid only for detecting the faults and for rectifications works. If any spare replacement needed in the work, the same shall be measured and paid under relevant item.
Supply and fix factory built hermetically sealed compressor unit suitable for 1.5 Ton, single phase, 230 V, 50Hz capacity split / window type AC, testing the leak of compressor by charging Dry Nitrogen gas, evacuating the system and charging R-22 /304 a /407a /134 Refrigerant gas including taking out old unserviceable compressor with connected old material from the split type ACs / window ACs complete all as specified and as directed.
`-Ditto- all as per item No 02 here in above but 2.0 TR
`-Ditto- all as per item No 02 here in above but from 2.5 TR to 3.0 TR
Material and labour for leak testing of Window / Split type ACs, Water cooler, Refrigerator, Deep freezer etc. including filling of nitrogen gas for pressure testing, finding leaks, Vacuuming the system, necessary brazing work, charging with refrigerant gas ( R-22 / R 304 a /R 407a /R 134 ) of required quantity, testing for proper functioning complete all as specified as directed
Material and labour for onsite servicing 1.5 / 2.0 / 2.5/ 3.0 Ton capacity split/ window type AC of any description by cleaning air filter, cooling coil/ condenser coil and outer cabinet with pressurised water and detergent solution, applying new insulation to torn/damaged insulation complete all as specified and as directed.
Supply and fix in repairs of condenser fan motor with capacitor and mounting materials, single phase, 230 Volts, 50 Hz suitable for 1.0/1.5/2.5 /3.0 Ton capacity split type AC including taking out old unserviceable blower motor complete all as specified and as directed.
Supply and fix in repairs of thermostat cut off switch suitable for 1.5 / 2.0 / 2.5/3.0 Ton capacity split / window type AC complete all as specified and as specified and as directed.
Supply and fix in repairs of overload protective relay suitable for 1.5/2.0/2.5/3.0 Ton capacity window type AC complete all as specified and as directed.
Supply and fix in repairs of starting relay suitable for 1.5 /2.0/2.5/3.0 Ton capacity window type AC complete all as specified and as directed.
Supply and fix in repairs of copper, aluminium mixed alloy condenser suitable for up to 1.5 Ton capacity split / window type AC complete all as specified and as directed.
Supply and fix in repairs of copper, aluminium mixed alloy condenser suitable for 2.0 Ton capacity split type AC complete all as specified and as directed.
Supply and fix in repairs of copper, aluminium mixed alloy condenser suitable for 2.5 up to 3.0 Ton capacity split type AC complete all as specified and as directed.
Supply and fix in repairs of 30 / 36 mfd running capacitor suitable for 1.5 / 2.0 / 2.5 Ton capacity split / window type AC complete all as specified and as directed.
Supply and fix in repairs of PVC fan blade suitable for 1.5/2.0/2.5 Ton capacity split / window type AC complete all as specified and as directed.
Supply and fix in repairs of Prime Control Remote Board and temperature digital display sensor suitable for split type/Window AC of any capacity, make or model all as per site requirement complete all as specified and as directed.
Supply and fix in repairs of liquid strainer suitable for 1.5 / 2.0 / 2.5 Ton capacity split type AC complete all as specified and as directed.
Supply and fix in repairs of capillary tube for 1.5 / 2.0 / 2.5 Ton capacity split type AC complete all as specified and as directed.
Supply and fix in repairs of factory built hermetically sealed compressor unit suitable for 285 / 310 / 340 ltr capacity Refrigerator, testing the leak of compressor by charging dry Nitrogen gas, evacuating the system and charging R-134 / R-600 Refrigerant gas including taking out old unserviceable compressor from the Refrigerator complete all as specified and as directed.
Supply and fix in repairs of thermostatic switch suitable for 175 / 205 / 285 / 290 / 310 / 340 ltr capacity Refrigerator complete all as specified and as directed.
Supply and fix in repairs of starting relay suitable for 175 / 205 / 285 / 290 / 310 / 340 ltr capacity Refrigerator complete all as specified and as directed.
Supply and fix in repairs of door switch suitable for 175 / 205 / 285 / 290 / 310 / 340 ltr capacity Refrigerator complete all as specified and as directed.
Supply and fix in repairs of drier filter of size 1/4" x 1/4" flare connection suitable for 175 / 205 / 285 / 290 / 310 / 340 ltr capacity Refrigerator complete all as specified and as directed.
Supply and fix in repairs of overload relay suitable for 175 / 205 / 285 / 290 / 310 / 340 ltr capacity Refrigerator complete all as specified and as directed.
Supply and fix in repairs of electronic fan motor, single phase, 230 Volts, 50 Hz suitable for 425 ltr capacity Deep freezer complete all as specified and as directed.
Supply and fix in repairs of thermostatic switch suitable for 425 ltr capacity Deep freezer complete all as specified and as directed.
Supply and fix in repairs of factory built hermetically sealed compressor unit suitable for 40 / 60 / 80 ltr capacity water cooler, testing the leak of compressor by charging dry Nitrogen gas, evacuating the system and charging R-134/R-22 Refrigerant gas including taking out old unserviceable compressor from the water cooler complete all as specified and directed.
`-Ditto- all as per item No 27 here in above but suitable for 100 / 150 Ltrs capacity complete all as specified and as directed.
Supply and fix in repairs of starting relay assembly suitable for 40 / 60 / 80 / 120 ltr capacity water cooler complete all as specified and as directed.
Supply and fix in repairs of running capacitor suitable for 40 / 60 / 80 / 120 ltr capacity water cooler complete all as specified complete all as specified and as directed.
Supply and fix in repairs of overload relay suitable for 40 / 60 / 80 / 120 ltr capacity water cooler complete all as specified and as directed.
Supply and fix in repairs of thermostatic switch suitable for 40 / 60 / 80 / 120 ltr capacity water cooler complete all as specified and as directed..
Supply and fix in repairs of 15mm dia brass chromium plated push cock / lifting cock suitable for 40 / 60 / 80 / 120 ltr capacity water cooler complete all as specified and as directed
Supply and fix in repair 15mm dia PVC high pressure release valve complete all as specified and as directed.
Supply and fix in repairs of condenser fan motor, single phase, 50 Hz, 230 Volts suitable for 40 / 60 / 80 / 120 ltr capacity water cooler complete all as specified as directed.
Supply and fix in repairs of 15mm dia, 450mm long, PVC connection with brass check nuts, complete all as specified as directed.
Supply and fix in repairs of liquid strainer suitable for any capacity of water cooler complete all as specified and as directed.
Supply and fix in repairs of capillary tube suitable for any capacity water cooler complete all as specified and as directed.
Material and labour for attending maintenance of water purifier cum water cooler, hot and cold, electrically operated, Best Water Doctor / Cross Field by servicing parts, attending break down, renewal of parts including checking the equipment by the Service Engineer of OEM complete all as specified and as directed. Notes: (i) Renewal of parts will be measured and paid as supply only under relevant items. (ii) The cost of labour and consumables required for renewal of parts shall deemed to be included in the unit rate quoted by the contractor.
Supply only D2 Main PCB suitable for water purifier complete all as specified and as directed.
Supply only compressor suitable for water purifier capacity up to 10 ltr complete all as specified.
Supply only solenoid valve suitable for water purifier complete all as specified and as directed.
Supply only two way valve suitable for water purifier complete all as specified and as directed.
Supply only PF candle (Industrial) suitable for water purifier complete all as specified and as directed.
Supply only PF Bowl & cap suitable for water purifier complete all as specified and as directed.
Supply only compressor relays suitable for water purifier complete all as specified and as directed.
Supply only compressor fan motor suitable for water purifier complete all as specified and as directed.
Supply only thermostat (cooler) suitable for water purifier complete all as specified and as directed.
Supply only thermostat (heater) suitable for water purifier complete all as specified and as directed.
Supply only heating element suitable for water purifier complete all as specified and as directed.
Supply and fix in repairs for plug top suitable for industrial socket/ normal 16 Amp socket complete all as specified and as directed
Material and labour for repair to voltage stabilizer 5 KVA by rewinding the main stabilizing unit and replacing PCB, sensing unit, power relay, connector piece and testing on completion all as specified and as directed.
`-Ditto- all as per item No 52 here in above but of up to 4KVA
Supply and fix in repairs of copper pipe OD of any size including connecting to split type AC and applying insulation complete all as specified and as directed.
Material and labour for general servicing of 10 KVA, UPS by servicing of all parts, tightening of all electrical connections, applying petroleum gelly to battery terminals, repair / renewal of battery leads, attending the break down, repair / renewal of any parts except battery complete all as specified and as directed.
Supply and fix in repairs of PCB suitable for 10 KVA, 3 phase UPS complete all as specified and as directed Make : Aplab/ Equivalent
Supply and fix in repairs of transformer unit for 10 KVA, 3 phase UPS complete all as specified and as directed. Make : Aplab/ Equivalent
Supply and fix in repairs of display unit for 10 KVA, 3 phase UPS complete all as specified and as directed. Make : Aplab/ Equivalent
Supply and fix in repairs of maintenance free battery 12 Volt, 42AH in fully charged condition complete all as specified and as directed.
Supply and fix in repairs of PVC drain pipe one metre long 32mm dia heavy duty with two Nos of galvanized adjustable clamps including taking down existing complete all as specified and as directed.
Supply and fix in repairs of PVC float valve suitable 15 mm dia assembly and comprising valve assembly AL rod, PVC ball for water cooler/ desert coolers including taking down existing complete all as specified and as directed. Make :- Paryag / Polytuff
Supply and fix in repairs of overload protector relay 2613 including taking down existing complete all as specified and as directed. Make: Techemshah/ Hitachi.
Opening of Refrigerator's freezer of capacity 285/310 ltr re-fixing the same after flushing out and removal of blockage brazing, renewal of liquid line filter and recharging the refrigerator with freon-12 refrigerant to obtain the desired cooling (Temperature) complete including testing all as specified and as directed .
`-Ditto- all as per item No.63 above but up to 265 ltr capacity refrigerator complete all as specified and as directed.
Supply and fix in repairs of Prime Control Remote Board and temperature digital display sensor suitable for 3 phase Tower AC of any capacity, make or model all as per site requirement complete all specified and as directed.
Supply and filling of Refrigerant Gas-R-22 in ACs/Water coolers/ Refrigerators of any model and capacity including leakage testing complete all as specified and as directed.
Supply and filling of Refrigerant Gas-410a (Penta & Di Fluoroethane)/ 304 a / 407a /134 ACs/ Water coolers/ Refrigerators of any model and capacity including leakage testing complete all specified and as directed.
Supply and filling of Refrigerant Gas R- 32, ACs/Water coolers/Refrigerators of any model and capacity including leakage testing complete all specified and as directed.
Material and labour for factory made Sealed compressor unit suitable for 2.5/3 TR capacity 3 phase Tower AC including first filling of refrigerant gas, compressor oil etc. testing and commissioning, including taking down of old unserviceable compressor complete all as specified and as directed.
Material and labour for servicing of condenser coil of Tower split AC 2.5/5 TR capacity, Cleaning / Pressure washing of choked condenser fins, tubes etc. with water soluble material including leak testing complete all as specified and as directed
Supply and fix in repairs of Fan motor suitable for outdoor unit of 3 phase tower AC of any capacity make or model all as specified and as directed.
Writing letters or figures for permanent marking of MES No with anti-corrosive enamel paint not exceeding 03 cm in height as numbers obtained from Engineer-in-charge in window AC/ Split ACs inner and outer unit and water cooler /refrigerator etc. with thick approved colour paint complete all specified and as directed.
Supply and fix in repairs of indoor unit and outdoor unit kit of 1.5 TR split type ACs of any make by dismantling the old indoor unit and outdoor unit connecting up with existing outdoor unit and indoor unit including complete indoor unit items like blower fan , PCB, / Remote controls etc. and excluding out door unit components like compressor, condenser fan motor and condenser unit, copper pipe complete set and necessary brazing as per site requirement etc. complete all as specified and as directed.
Supply and fix in repairs of indoor unit and outdoor unit kit of 2.0 TR split type ACs of any make by dismantling the old indoor unit and outdoor unit connecting up with existing outdoor unit and indoor unit including complete indoor unit items like blower fan , PCB, / Remote controls etc. and excluding out door unit components like compressor, condenser fan motor and condenser unit, copper pipe complete set and necessary brazing as per site requirement etc. complete all as specified and as directed.
Material and labour for disconnection the power supply of split ACs and dismantling, taking down split ACs, any make /mode/type of capacity 1.5/ 2.0TR from existing location including indoor units/ outdoor units along with its copper pipes, connecting cables, clamps/ stands, water drain pipes etc. including making good the surfaces to match with existing finishes in all respects and re-fixing at new location as directed with all accessories such as clamps, pipes, stand for outdoor unit including top up of refrigerant gas if required and making satisfactory working of AC unit in all respect complete all as specified and as directed.
COCHIN CHEMICALS (BID ID -3470048)
Jack Electrolinks Private Limited (BID ID -3470972)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
8275Tenderdocu.pdf
Tender Documents • 0.82 MB
BOQ_823574.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid