Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAccepted-AOC 21 A MALVIYA NAGAR AIR FORCE AREA JODHPUR RAJASTHAN 342001 | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC ACCEPTED BEING LOWEST QUOTED | |
| 2 | L2₹30.7 L+₹5.4 L (21.1%)Rejected-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L2 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 3 | L3₹33.9 L+₹8.5 L (33.7%)Rejected-AOC | L3 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
Tender Value
Refer Docs
EMD Value
₹57,400
Closing Date
19 Jan 2023, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
SPL REPAIR TO BLDG NO P 07 P-08 ROOF TREATMENT TO BLDG NO P 419 P 220 AND PROVN OF SIMULATOR ROOM AT MIL STN GANDHINAGAR
2022_MES_570464_1
GE(A)/GNR/TOKEN/70 of 2022-23
Open Tender
Civil Works
Item Rate
90 days
MIL STN GANDHINAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE ARMY GANDHINAGAR
₹57,400
Yes
8 Feb 2023
21 Dec 2022
21 Jan 2023
21 Dec 2022
19 Jan 2023
2 Jan 2023
21 Dec 2022 - 31 Dec 2022
Amount
M&L for surface dressing nexc 15 cm deep and getting out in Soft/ Loose soil complete all as specifed and directed.
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in soft/ loose soil complete all as specifed and directed.
Returning filling in foundation including spreading, watring and well ramming in layer n.exc 25cm each in loose/soft soil complete all as specifed and directed.
Spreading and levelling under floor layers not exceeding 25 cm thick and well ramming including watering as required complete all as specifed and directed.
Removing excavated material exc 250m and depositing where directed at a level n exc 500 m above the starting point in soil complete all as specifed and directed.
Removing rubbish to a distance exc. 1.5 Km but not exc. 5.0 Km out side MD land complete all as specified and directed.
M&L, Hardcore of broken stone of gauge n exc 63mm deposited, spreaded & levelled in layers n exc 15cm thick including watering and ramming etc complete.
M&L PCC 1:4:8 type D-2(40mm graded aggregate) in foundation , sub base, filling and mass concrete complete all as specifed and directed.
M&L design mix RCC M-25 grade concrete in foundation including raft,footing foundations beem ,plinth beams base for coloumn etc. complete all as specifed and directed.
M&L design mix RCC M-25 (using 20 mm graded granite stone aggregate) for slabs suspended on walls, beams and columns, in floors, roofs, landings and in shelves and the like complete all as specifed and directed.
M&L design mix RCC M-25 in lintel beams/lintels, roof beams over 1.50 mtr span complete all as specifed and directed.
Supply only, liquid water proofing compound mixed as per manufacturer instructon mixed in cement concreter or cement mortar complete all as specified and directed.
Removing existing water proffing /black top treatment from parapet wall, removing material to a distance exc. 1.5 Km but not exc. 5.0 KM out side MD land complete all as specified and directed.
M&L for water proofing treatment to non accessible roof slabs by applying one coat of cold bituminous primer @ 0.30 litre/sqm and conforming to IS-3384, laying APP based polyster modified membrane reinforced non wooven polyster of 3.50 Kg/Sqm (minimum), 3mm thick with plain polythene finished and sealing all the overlap 75mm in length side and 100mm in width side of membrane by torching including applying one coat of bituminous aluminium paint over membrane all as specified and directed .
M&L for Brick work with sub class old 'B' bricks, straight or curved on plan exc. 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for fly ash Brick work with old size, sub class 'B' bricks, straight or curved on plan exc. 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as steps, cooking platform, and other similar situations complete all as specified and directed.
M&L 16 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
Form work to sides of concrete foundations footing bases of coloumn raft and raft beams sides and soffits of plinth beams and similar works vertical or to batter complete all as specifed and directed.
Rough finished flat form work to soffits of suspended slabs such as roof slabs, floor slabs and similar work not exce 200 mm thick.
Form work to sides of lintel beams and roof beams hunching griders braessummers lintel vantilivers etc. complete all as specifed and directed.
Rough finished flat Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specifed and directed.
S&F, 35 mm thick 2nd class hard wood plain framed panelled shutter (two panel) with lock rail and panel of 12 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS 1003 (Part -I), Klin seasoned and chemically treated and complete all as specified and directed.
S & F 200 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specifed and directed.
S&F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specifed and directed.
S&F, butt hinges, medium weight, cold rolled, mild steel of size 100 mm complete all as specified and directed.
S&F, 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specifed and directed.
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor
S&F Aluminium alloy wire cloth. 0.45 mm nominal dia of wire and average width of aperture 1.4 mm and fixed with aluminium wire staples complete all as specifed and directed.
S&F mild steel work as in holdfast/wind tie etc made out of flat iron including necessary welding or fixing nuts and bolts complete.
S&F framed work such as grills, grating etc with ends of bars shoulderd or rivetted or forcged into spikes ,framed guard bars, barred iron doors congirming to FE 290 Gde E-165 complete all as specified.
S&F, Mild Steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking , bending, hooking etc and binding with MS wire 0.9mm dia(annealed) complete all as specifed and directed.
S&F, mild steel TMT bar 8mm dia ,cut to length, bent to shape reqd including cranking, bending , hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specifed and directed.
S&F, mild steel TMT bar 5mm dia ,cut to length, bent to shape reqd including cranking, bending , hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specifed and directed.
M&L Rolled mild steel sections conforming to Gde Fe-410-0 or Fe-310-0 as in framing for cladding, glazing and the like including door frames/ chowkats, coolerstand etc fixed with angle cleats and connecting plates, etc complete all specified and directed.
S&F, powder coated Aluminium windows/ ventilators with one or more rebates including joining cleat for fixing etc complete with frames, shutters and grills of size directed by Engineer-in-charge including handles, tower bolts, grills, etc complete all as specified and directed. Note:- sheet glass, wire cloth, lock, etc shall be measured and paid seperately.
S&F, Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet, 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F, Pre-painted galvalume aluminium zinc coating GI based plain steel sheet, 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for 40mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in floors and finishing the top surface even and smooth without using extra cement complete all as specified and directed.
M&L for 75mm thick cement concrete 1:3:6 type C1, using 40mm graded stone aggregate as in plinth protection, finishing cement concrete surfaces even and smooth without using extra cement, Joints of plinth protection shall be filled with bitumen mastic (1:3) complete all as specified and as directed.
M&L for 75 mm thick cement concrete 1:3:6 type C1, using 20mm graded stone aggregate as in plinth protection, finishing cement concrete surfaces even and smooth without using extra cement, Joints of plinth protection shall be filled with bitumen mastic (1:3) complete all as specified and as directed.
M&L for 100 mm thick PCC 1:4:8 type D-2( 40 mm graded stone aggregate ) as in sub base of flooring complete all as specified and directed.
M&L for 40 mm thick (average consolidated thickness) PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate mixed with liquid water proofing compound as per manufacturer instruction, laid in slope 1:30 on roof as in padding, finished even and fair complete all as specified and directed.
S&F non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tiles exceed.18 sqm but not exc.0.36 sqm , in floors etc etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to matchincluding 15 mm thich screed bed of CM (1: 6)
S&F non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tiles exceed.18 sqm but not exc.0.36 sqm, in skirting etc etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to matchincluding 10 mm thich screed bed of CM (1:3)
M&L for rendering 10mm thick in cement mortar (1:6) on brick work /concrete work /stone masonry surface or surface other than fair face of brick work finished surface even and fair without using extra cement complete all as specified and directed.
M&L for rendering cement plaster 5mm thick in cement mortar (1:3) on fair faces of stone / concrete in ceilings, chajjas, fins facia etc.complete all as specified and directed.
M&L for rendering cement plaster 10mm thick in cement mortar (1:6) on brick work or concrete surfaces of walls, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10 mm thick on on fair faces of concrete surfaces as on PCC padding in CM 1:3 mixed with liquid water proofing compound as per manufacturer instruction and finish the surface even and smooth without using extra cement for laying APP membrane at non-accessible roof (mumty) all as directed. (Note :- water proofing compound shall be measured and paid sepretally)
M&L for rendering cement plaster 12mm thick in cement mortar (1:4) on brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
Taking down cement plaster on brick or stone wall etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
S&F in repair 25mm dia, 1mm wall thickness stainless steel fancy type heavy duty curtain rod with decorative ball type side brackets (as per sample) fix with wooden gutties complete all as specified and directed.
M&L for cutting uneven surfaces of concrete & cutting reinforcement from drops of fins & facias (thickness not exceeding 50mm) using necessary scaffolding and making good the disturbed portion with 5mm thick rendering in CM 1:3 finished even and smooth without using extra cement etc. complete all as specifeid and directed.
M&L for preparing new plastered or un-plastered wall surfaces and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of white cement as primer complete all as specified and directed.
M&L for preparation of new plastered or un-plastered surfaces of wall and applying two coat of cement base paint over priming coat of white cement complete all as specified and directed.
M&L for two coats of oil bound distemper over one coat of 1mm thick wall care putty ( Make : Birla/JK White) base on newly plastered surfaces of wall including preparation of surfaces complete all as specified and directed.
M&L for preparation of old decorated plastered or unplastered wall surfaces including brooming down or steel wire brushging, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of white wash complete all as specified and directed.
M&L for preparation of old decorated plastered or unplastered wall surfaces including brooming down or steel wire brushging, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of cement base paint complete all as specified and directed.
M&L for preparing new plastered or un-plastered ceiling surfaces and applying three coats of white wash complete all as specified and directed.
S&F, 4 mm thick, black tinted glass panes fixed to aluminium windows/vents with necessary rubber gaskets complete all as specified and directed.
M&L for preparation of new wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of pink primer with two coat of Synthetic enamel paint all as directed and specified.
Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
S&F steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and directed for 20mm bores of pipe complete all as specified and directed.
S&F steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and directed for 25mm bores of pipe complete all as specified and directed.
Taking up or down steel tubing and connections complete all as specified and directed for the 20MM bores of pipe complete all as specified and directed.
Taking up or down steel tubing and connections complete all as specified and directed for the 25MM bores of pipe complete all as specified and directed.
Refixing old serviceable steel tubing and connections in new or old position (walls, ceilings, floors etc.) complete all as specified and directed for 20mm bores of pipe complete all as specified and directed.
Refixing old serviceable steel tubing and connections in new or old position (walls, ceilings, floors etc.) complete all as specified and directed for 25mm bores of pipe complete all as specified and directed.
Disconnecting, setting aside (or lowering if required) and Cleaning & removing all scale and dirt etc from HDPE water tanks of 500 litres capacity (Tanks placed on top of roof) and from mouths of circulating pipes etc including washing the tank with bleaching powder and hoisting, reconnecting and re-fixing in position including writing the date of cleaning of tank with synthetic enamel (black/white) paint of size not less than 10cm of each letter complete, all as specified and directed.
Supply, hoisting and fixing in position in repairs, 500 litres capacity rotational moulded polyethylene water storage tank double layered (cylindrical, vertical with closed top) including dismantling of old PVC/AC water storage tank of 500 liter capacity complete all as specified and directed.
Supply, hoisting and fixing in position , 500 litres capacity rotational moulded polyethylene water storage tank double layered (cylindrical, vertical with closed top) including dismantling of old PVC/AC water storage tank of 500 liter capacity complete all as specified and directed.
S&F in repair, Gun metal globe or gate valve, with iron wheel head, screwed both ends for iron pipe for 25 mm bore of pipe complete all as specified and directed.
S&F in repair, Gun metal globe or gate valve, with iron wheel head, screwed both ends for iron pipe for 20 mm bore of pipe complete all as specified and directed.
S&F, 20mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.(Minimum weight -210 Gms) complete, all as specified and directed.
S&F in repair 20mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.(Minimum weight -210 Gms) complete, all as specified and directed.
M&L for Cement Concrete type B-2, 1:2:4 using 40 mm graded crushed stone graded agg as in fdn filling and mass concrete (water storage tank platefom) complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exc. 15cm thickness (below or above ground level) all as specified and directed.
Demolition of reinforced cement concrete of any description etc complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for all as specified and directed.
Dismantling Asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings complete all as specified and directed.
Taking down carefully unserviceable copper/aluminium point wiring (Light, fan, socket or power) complete including unserviceable fittings and fixtures such as switches, ceiling roses, pendents, regulators, sockets, lamp holders, brackets, except ceiling fittings, bulk head fittings, tube light fittings etc. and making good the disturbed surfaces of walls, floors, etc. complete all as specified and directed.
M&L for wiring with and including multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with valid CML number, drawing through in and including, rigid non metallic, PVC concealed conduit of 20mm bore and including cutting chases for conduits and sinkings for boxes, its accessories & including with multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with valid CML number as continuity earth wire terminating with provision sunken concealed terminal boxes complete all as specified and directed for the following :-
(a) One light/fan /Exhaust point controlled by one switch
(b) One multi purpose socket 5 Amps, Independent board
(c) One multi purpose socket 5 Amps, on the same board
M&L for wiring with and including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. complete all as specified and directed for the following :- Make of Cable Polycab/Finolex/Havells
(a) One light/fan point controlled by one switch
(b) One 3 pin, 5 Amps, socket outlet on the same board controlled by another switch.
(c) One multi pin 5 Amps, socket outlet on Independent board.
M&L for wiring with and including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC concealed conduit of 20mm bore fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box complete all as specified and directed.
M&L for wiring with and including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. for one 3 pin, 15 Amps socket outlet point on independent board complete all as specified and directed. Make of Cable Polycab/Finolex/Havells
S&F, lamp holder insulated body with back plate for battern fittings complete all as specified and directed.
S&F, in repair, switch piano, flush button single pole, one way 5 Amps complete all as specified and directed.
S&F, switch piano, flush button, single pole, one way 15 Amps complete all as specified and directed
S&F, Ceiling rose, PVC/poly carbonate,isolated body three terminals,complete all as specified and directed.
S&F, socket outlet, 2 in 1, 3 pin, 15 Amps and 5 Amps flush type complete all as specified and directed
S&F, in repair, socket outlet 2-in-1, 3 pin, 5 Amps, flush type complete all as specified and directed.
S&F, ceiling fans complete with blades, down rods, electronic regulator and accessories 230 V, 1200mm sweep Min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
S&F, miniature circuit breakers, type curve ‘B’ , 10 KA, SP, 6 to 32 Amps complete all as specified and directed.
S&F, miniature circuit breakers, Single pole and neutral, type curve ‘B’ 10KA, 40 Amps 230 Volts. complete all as specified and directed.
S&F, in repairs, sheet metal distribution board, SPN, 8 way 240 Volt, double door factory made and tested complete, protection class IP-42 suitable for mounting MCBs, isolator with 200 A tinned copper bus bar complete all as specified and directed
M&L for ceiling rose, PVC/poly carbonate, isolated body three terminals complete all as sepcified and directed.
S&F, in repairs, LED light fitting, batten type, housed in extruded from powder coated aluminium, 20 watt complete set flexible three core copper conductor cable of suitable size and testing on complete all as specified and directed.
ALBA AC AND REF SERVICES
Ramdev and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .