Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L2₹56,985Qualified Make: zebronic
Model: ZEBRONIC ZEB-U1200 1213 DARIYAPUR DARIYAPUR TIRAHA SULTANPUR UTTAR PRADESH 228001 | SULTANPUR | UTTAR PRADESH | 228001 | Make: zebronic
Model: ZEBRONIC ZEB-U1200 | L2 | Qualified | |
| 2 | L3₹59,985Qualified Make: zebronic
Model: ZEBRONICS ZEB-U1000 PLUS 2 RANA SAMAY SINGH DURG MAHARANA PRATAPGARH KAKROLA VILLAGE SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | Make: zebronic
Model: ZEBRONICS ZEB-U1000 PLUS | L3 | Qualified | |
| 3 | L4₹64,200Qualified Make: microtek
Model: Microtek Line Intractive 1.0/800 with 2 year warranty 1 B VASHISHT NAGER BABYAL ROAD NEAR HARYANA GRAMIN BANK AMBALA CANTT AMBALA HARYANA 133001 INDIA | AMBALA | HARYANA | 133001 | Make: microtek
Model: Microtek Line Intractive 1.0/800 with 2 year warranty | L4 | Qualified | |
| 4 | L5₹65,940Qualified Make: microtek
Model: MICROTEK TWIN GARD 1000VA A 103 BHARAT NAGAR NEW FRIENDS COLONY NEW DELHI SOUTH DELHI DELHI 110025 | SOUTH EAST DELHI | DELHI | 110025 | Make: microtek
Model: MICROTEK TWIN GARD 1000VA | L5 | Qualified | |
| 5 | L6₹65,985Qualified Make: Intex
Model: INTEX 1 KVA ups 1 206 54 S D MANDIR MARKET SADAR BAZAR S D MANDIR MARKET SADAR BAZAR DELHI CANTT NEW DELHI | Make: Intex
Model: INTEX 1 KVA ups | L6 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
16 Jul 2018, 9:00 pmClosed
Line Intractive UPS with AVR Line Intractive UPS With AVR ( 15 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/800 1.0/800 Technology MOSFET-PWM MOSFET-PWM
IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 Rated Output (Volt) Single phase sinewave 230v AC
50Hz Single phase sinewave 230v AC
50Hz
Single Phase Quasi-Sin-wave 230 V AC
50 Hz Degree of protection IP-21 IP-21
IP 20 Inverter Efficiency (%) >/= 70% >/= 60%
>/= 70% Warranty for the battery from the date of delivery 1 year - Warranty for Line Interactive UPS 2 Years 1 Year
2 Years
5 Years Installation and commissioning instructions Yes - CONSTRUCTIONAL Type of enclosure ABS - AC out put for No Yes
No 1/4 printer (not through inverter) Inverter out put socket AC out put for printer (not through inverter) Not applicable 2 Three pin
3 Three pin
Hard wiring
Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%
50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts
the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree
RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes - Dry heat Test at 45 Yes - 2/4 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date 1552
29.07.2011 - Name Of Lab ETDC - Address of Lab Ambala - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Divey Saib 788025
160 Military Hosp Masimpur Silchar 15 45
303265
GEM/2018/B/43031
Line Intractive UPS with AVR
45 days
Assam; Cachar
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Line Intractive UPS with AVR Line Intractive UPS With AVR ( 15 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/800 1.0/800 Technology MOSFET-PWM MOSFET-PWM | - | - | - |
| IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 Rated Output (Volt) Single phase sinewave 230v AC | - | - | - |
| 50Hz Single phase sinewave 230v AC | - | - | - |
| 50Hz | - | - | - |
| Single Phase Quasi-Sin-wave 230 V AC | - | - | - |
| 50 Hz Degree of protection IP-21 IP-21 | - | - | - |
| IP 20 Inverter Efficiency (%) >/= 70% >/= 60% | - | - | - |
| >/= 70% Warranty for the battery from the date of delivery 1 year - Warranty for Line Interactive UPS 2 Years 1 Year | - | - | - |
| 2 Years | - | - | - |
| 5 Years Installation and commissioning instructions Yes - CONSTRUCTIONAL Type of enclosure ABS - AC out put for No Yes | - | - | - |
| No 1/4 printer (not through inverter) Inverter out put socket AC out put for printer (not through inverter) Not applicable 2 Three pin | - | - | - |
| 3 Three pin | - | - | - |
| Hard wiring | - | - | - |
| Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9% | - | - | - |
| 50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts | - | - | - |
| the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree | - | - | - |
| RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes - Dry heat Test at 45 Yes - 2/4 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date 1552 | - | - | - |
| 29.07.2011 - Name Of Lab ETDC - Address of Lab Ambala - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Divey Saib 788025 | - | - | - |
| 160 Military Hosp Masimpur Silchar 15 45 | - | - | - |
Exempted
16 Jul 2018
6 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_303265.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .